Loading...
HomeMy WebLinkAbout21-2711City f yrhills Mlallllkli= ��'`Y�1r�;y1ta 5335 Eighth Street p Zephyrhills, FL 33542 BNR- 2711-2 21 Phone: (813) 780-0020 Fax: (813) 780-0021 issue Date: 0910912021 Permit : Building Newidntil 6686 Cobble Bliss St 04 26 21 0130 01000 0150 \1z`•{tZ,'� t.;`, t": +:\tivQv`t: t=(tj sit. .,�t�i} Z.... vz. S'i\t`i U, `Z=� } Oil Name: D R HORTON Permit Type: Building New (Residential) Contractor: D R HORTON INC Class of Work: SFR Construct Address: 12602 Telecom Dr Building Valuation: $140,000.00 TAMPA, FL 33637 Electrical Valuation: $7,000.00 i Phone: (813) 549-1968 Mechanical Valuation: $6,000.00 gt . Plumbing Valuation: $8,000.00� Total Valuation: $161,000.00 Total Fees: $14,600.69 Amount Paid: $14,600,69 Date Paid: 9/9/2021 2:03:56PM� e , <t kv v x{ :1 .Avt r1. \m \ \ t b k et F 1 t ut L t tz CONSTRUCT SINGLE FAMILY 3,167 ZL \ S\t\10t \?zz:� .t\\u .1'\�t.\;,tti. .�.\v \`•x, `i.�\,\.. zh, \lt,, `.\b\\t,a 4 ?t Public Safety Impact Fee -Admin $26.35 Park Impact Fee - Single Family/Townhome $769.56 Public Safety Impact Fee -Police $254.00 SIF 1 percent Fee $83.28 School Impact Fee $8,328.00 Electrical Permit Fee $75.00 Electrical Plan Review Fee $37.50 Transportation Impact Fee $3,595.68 Driveway Fee $45.00 Mechanical Plan Review Fee $35.00 Building Plan Review Fee $365.00 Mechanical Permit Fee $70.00 Address Fee $30,00 Plumbing Permit Fee $80.00 Transportation Impact Fee - City $36.32 Building Permit Fee $730.00 Plumbing Plan Review Fee $40.00 REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications add fee gust Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. A� CONTRACTOR SIGNATURE t • • .,, iI weltly•.• !Iff X_1=0ftr4Rf .. i W&4f I ME , • PASCO COUNTY, FLORIDA Permit No, 2-7 1 Date Permitted Builder Name/Owner Name Control # County Parcel No. SubDiv: Address/Location Ub b Ej- Classificationrrype of Use slyv TRANSPORTATION IMPACT FEE Rate: Sq. Ft Unit: Exempt ElVes E] No How Determined Impact Fee Amount . I at 32- Zone No. _ TAZ: GTf E Account (056) Single -Family Detached House Amount $ (057) Mobile Home (058) Other Residential ---------- 4123) Collection Fee Exempt U yer, E] No How Determined Land Account Land Credit Land Total Recreatl on Account _ Recreation Credit _ Recreation Total Zone TOTAL AMOUNT $ Exempt []Yes []NO How Determined Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt 0 Yes El No HowDetermined _ TotajAmount-�. TOTAL AMOUNT Chocked By Acknowledoement below does not linply aMptancs of ooncuffence but sl@4 111 lktv RECEIPT NO. _DATE I BY City Of Zephyrhills Permit Application Building Department Date Received Phone OOntact fo r Owner's Name Owner's Address Fee Simple Titleholder Name Fee Simple Titleholder Address JOB ADDRESS SUBDIVISION WORK PROPOSED NEW CONSTR PROPOSED USE INSTALL SFR TYPE OF CONSTRUCTION BLOCK #ESCRIPTION OF WORK SQ • O F'O IWOUILDING SIZE STAGE� =BUILDING =ELECTRICAL $ [PLUMBING =MECHANICAL GAS ROOFING FINISHED FLOOR ELEVATIONS PARCEL ID# ADD/ALT REPAIR Comm FRAME Owner Phone Number 3�L Owner Phone Number Fax-813-780-0021 C.( r7 Owner Phone Number E=== LOT # k1J0 I AIN LD FROM PRO pERTyTA—X-RC-)T-1C`E-) SIGN DEMOLISH OTHER STEEL HEIGHT VALUATION OF TOTAL CONSTRUCTION AMP SERVICE PROGRESS ENERGY W.R.E.C. VALUATION OF MECHANICAL INSTALLATION 411 SPECIALTY OTHER FLOOD ZONE AREA =YES NO BUILDER SIGNATURE COMPANY REGISTERED Address Y/ N FE CURRE Y/N E---LECTRICIAN License SIGNATURE COMPANY. REGISTERED 7 Address IIERUKE�N� N :'LUMBER License 3 � 3IGNATURE COMPANY Address REGISTERED Y/ N FEE CURR N /N AECHANICAL License # ;IGNATURE COMPANY REGISTERED V E cul Address -N Y/N )THER License # --CA-U 33 IGNATURE COMPANY Address REGISTERED Y/ FEE CURREN Y/N License # E I SIDENTIAL Attach (2) Plot Plans; (2) sets Of Building Plans; (I) Set of Energy Forms; R-0 Minimum ten (10) working days after submittal date. Required onsite, Co * -W Permit for new construction, Sanitary Facilities & I dumpster;,gite Construction Plans, Stormwater Plans W1 Slit Fence installed, OMMERCIAL Attach (2) Work Permit for subdivisions/large projects Minimum ten sets Of Building Plans Plus a Life Safety Page; (1) set of Energy Forms, R,O-W Perm!mast t for new construction. On (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans W/ Silt Fence installed, Sanitary Facilities & I dumoster. Site Work Permit for all new projects, All commercial requirements mustIGN PERMIT Attach (2) sets of Engineered P.I'ans. compliance ""PROPERTY SURVEY required for all NEW construction. Irections: Fill Out application completeete ly, Owner & contractor sign back Of application, notarized If over $2500, a Notice Of Commencement is required. (A/C upgrades over $7500) Agent (for the contractor) Or Power of Attorney (for the Owner) Would be someone with notarized letter from �ER THE COUNTER PERMITTING ,roofs if shingles (copy of contract required) owner authorizing same Sewers Service Upgrades A/C Fences (plot/Survey/Footage), Driveways -Not over Counter if on Public roadways_needs ROW NOTICE OFDEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may bemore restrictive than County regulations, The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a�contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as. required by {ovv, both the owner and contractor nay be cited for s misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing. Section at 727-847- 8009. Furthernnore, if -the owner has hired e contractor or contraotoro, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that heia not properly licensed and is not entitled to permitting privileges in Pasco County, TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES : The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also undarstands, that such fees' as may be dua, will be identified at the time of permitting. It is further;understood that Transportation Impact Fees'and Resource Recovery Fees must be paid prior to receiving o "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power. release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County WaterlSevver Impact fees are due, they must'be paid prior to permit issuance in accordance with applicable Pasco County ordinances, CONSTRUCTION LIEN LAW (Chapter 713'Florida Statutes, os amended): \fvaluation ofwork |e$2.5O8.DDormore, | certify that |, the epplioent, have been provided with o copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "ovvner"'|certify that ihave obtained a copy of the above described document and promise in good faith to deliver ittothe "ovvner"prior tocommencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated, \ certify that no vvork or installation has commenced prior to issuance of permit and that all work will be performed to meet standards Of all (avvo regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. \ also certify that | understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include, but are not limited to: - Department ofEnvironmental Protection -Cypress Bayheada, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. ' Southwest Florida Water Management District -Wells, Cypress Boyheode, Wetland Areas, Altering Watercourses. - Army Corps ofEngineera'GeavvaOs. Docks, Navigable Waterways. - Department of Health & Rehabilitative Servicea/Environrnanta| Health Unit -Wells, VVeotavvater Treatment' Septic Tanks, - US Environmental Protection Agency -Asbestos abatement. - Federal Aviation Author|ty-Ronvvayo. \ understand that the following restrictions 'apply tothe use offill: ' Use offill ionot allowed |nFlood Zone "V"unless expressly permitted. - |fthe fill Material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "coG0peOootiOQ volume" will be submitted at time of permitting vvh|Oh is prepared by 8 professional engineer licensed bythe State ofFlorida. - If the f|||'nraterial is to be used in Flood Zone ''/Y' in connection with o permitted building using stem vva|| construction, | certify that fill will be used only tofill the area within the stem wall. - If fill 0BtGha\ is to be used in any area, | certify that use Of such fill will OOt adversely affect adjacent properties, If use of fill is found to adversely affect `@c8Dt properties, the'owner may be cited for violating the conditions of the building permit issued under the attached permit application, for |nta less than one (1) acre which are elevated byfill, anangineereddrainage plan iorequired. If ( am the AGENT FOR THE OWNEFl, i promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to oo0r09DCing construction, \ understand that a separate permit may be required for electrical work, p|uOnbing, sigO2, vv8||s, pools, air ooDditioning, gas, or other installations not specifically included in the application, A permit issued shall be construed to be a license to proceed with the work and not as authority toviolate, cancel, alter, or set aside any provisions of the technical oodee. nor shall issuance of permit prevent the Building Dff|o|ed from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by thaperOnitisauopeDdedorebendonedfqroperiodofeix(0)nnoAtheafterthet|0ethevvorkiacorOrnenced. Anox1ensioD may be requestod, In writing, from the Building Official for a period not to exceed ninety /QO\ days and will demonstrate Justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned, FLORDAJU ��. OWNER OR AGENT CONTRACTOR )9 "'LA Notary Public Commission No. Commission No. Notary Public Name of Notary typed, printed or stamDed Notary PublIC State Of FlWda Michelle Moyes Name of Notary typed, printed or stamped I , F,[',,,F, shall be as minfinuin of 8" above the road elcvation and aui engineered site plan, 2, I-ots shall be graded to cornply xilli R401,3 of the F,B'C', 3, Cornpaction test requir,ed it'24" or more agile till dirt. is brought in at ern v one place, 4, Tie in sukrvey required before pourinig concrele, 5, Drivew av's requirc as R,O,W, iuse perniii, All 4 sides ofdriveway thru the sidewalk shall have expansiort niaterial, 6.. All scilbacks shall be ma 7, All properly rnarkers shall be uncovered and marked at fin -re offirst inspectiOn, 8, All MIA, reqtdrements shall be met, 9, No elcoric, plumbing, nrechanical, or ftru,ning shall bc covered withom an ESispeclion and approval first, M All (InIrrages shall comply with section R3102,6 of the H3,C, (Fire Separatiorl), 11, Appliances shall not be installed In it location -Nvhere subJect to ntechanical damage urfless protected by approved baffiers, M303A of the F.B,C 12 Water heaters shall comply with section P607-3 ofthe I-,A3,C', 13, Foundation supports Cor A/C' units shall be raised at least 3" ,above firuslied grade, M 1308,1 14, Relurn air in all bedroorns, FRC, \14 1620A 15, Smoke detectors are to be installed in accordance with R3 13A ofthe F,B.C', 16 All glazing requirernerits are to be ire accordance wid'i R308,4 ofthe RB,C. IT All nicans of egress are to be ivi accordance with R3 I I ofthe FB,C, 18, "Green gypsum board" shall not be used as a backer in shovver's of, tubs, R702.4,22 F,B,(', 19, Combinatioir-type AU'Cl breaker's arc required at all locations requiring an AFCJ ty )e breaker, 20. CaChon inonoxide alari'vis vvill be require(I in new constrixtion that uses fossil -bUt'11111t!, heating or appliances or air attached garage "I"Irey shall be installed in accordance with the F,B,(-", 21, All plumbirig, rnechanical, and ellect-ical shall be separalc ti0111 await to unit. 1"his includes all UYI(ICI-O'01,11111d pluitibing and electric z, Z, , All 2016 N F-C, Codes will be enforced, M e 23 Runper- i csrstant receptacles in accordance with 406,11 ofthe .121016 N.f?, ° 24, In accordance with the Land Development eloprrrr;nt Code, lots shall I)c sodded bef'or°e filial at least 10 feet around try: strrrclurc. 25, R403,5,3,Hot water pipe insulation InSUlation for hot water pipe with a mini}r,rrM thermal resistance (R,-vale) of R-3 shall be applied to the Piping I, inch (19A grim) and larger in nor°rtin l di rn t r, Piping serving ing more than one dwelling trait, Piping located outside the conditioned space, Piping from the water heater to a distribution manifold, Piping located c,rnder a floor slab— Buried in piping, Supply and return piping in recirCUlation systems other than demand recirculation systerns, 25. Blower door test shall be providedb� for C.O. 2r s r 8 F t ° r tart11 filne& ' %se�a�� [e°aEa�s°1'#t bka F`re3?a F.F.E.-Finished Floor Elevation F.B.C- Florida wilding Code 6th Edition R.O.W.-Right of Way A.D.A.- Americans with Disabilities. Act N.E.C.- National Electric Code (2016) PLOT PLAN DESCRIPTION:(AS FURNISHED) LOT 15, BLOCK 10, SILVERADO RANCH SUBDIVISION PHASE 5B AS RECORDED IN PLAT BOOK 81, PAGE(S) 69-73, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. Curve Table Curve # Length Radius Delta I Chord Bearing I Chord C1 14.41' 55,00' 15'0)'28" N59'35-26-W 1 14.37' ON LOT CALCULATIONS LOT = 7,484 SQ. FT. LIVING AREA = 2,372 SQ. FT. GARAGE = 538 SQ. FT. ENTRY = 30 SQ. FT. LANAI = 207 SO. FT. PATIO = 0 SQ. FT. DRIVEWAY = 610 SQ. FT. A/C PAD = 12 SQ. FT. WALKWAY = 37 SQ. FT. IMPERVIOUS = 51% 3806 SQ. FT. SOD = 3,678 SQ. FT. OFF LOT CALCULATIONS RIGHT OF WAY = 749 SQ. FT. DRIVE APRON = 229 SQ. FT. PUBLIC S/W = 321 SQ. FT. SOD = 199 SQ. FT. TOTALS AREA = 8,233 SQ. FT. DRIVEWAY = 839 SQ. FT. SIDEWALK = 358 SO. FT. SOD = 3,877 SQ. FT. BUILDING SETBACKS FRONT: 22' 1/0. REAR: 13' SIDE: 7.5' SIDE STREET: 22' NOTES: zz a 19, 1. ELEVATIONS SHOWN ARE PER LOT GRADING 0" PLANS PROVIDED BY THE CLIENT. 0c, 2. ELEVATIONS ARE BASED ON NAVD 1988 DATUM. 3. FOR ALL LOTS WHERE SIDE —YARD SETBACKS ARE LESS THAN 7.50 FEET, A ­­­ 500 FOOT ManC nDAWAGiI7 AND RIGHT OF WAY LINE ACCESS EASEMENT IS REQUIRED PER PASCO COUNTY LAND DEVELOPMENT CODE. THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF THE PROPOSED HOUSE. REFER TO HOUSE PLAN AND OPTION LIST FOR CONSTRUCTION. ALL BUILDING SET BACK LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT AND IS FOR INFORMATIONAL PURPOSES ONLY. THIS IS NOT A SURVEY THIS IS A PLOT PLAN ONLY I HAVE EXAMINED THE F.I.R.M. MAP NO. 12101CO288F, DATED SEPTEMBER 26, 2014, AND FOUND THE SUBJECT PROPERTY APPEARS TO LIE IN ZONE "X", AREAS DETERMINED TO BE OUTSIDE THE 0' 2% ANNUAL CHANCE FLOOOPLAIN. THE SURVEYOR MAKES NO GUARANTEES AS TO THE ABOVE INFORMATION, PLEASE CONTACT THE LOCAL F.E.M.A. AGENT FOR VERIFICATION, BEARING BASIS: 3EARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF STELLA VAST STREET BEING N52*05'12"W, PER PLAT. (FIELD DATE:) SCALE: I" - 30 FEET APPROVED BY: JB 200646 LOT 15 BLOCK JOB NO. 10. DRAWN BY: DSB PLAN CHANGE 07— PLOT PLAN 06/30, mommm BUILDING SETBACK LINE CENTERLINE PROPOSED ELEVATION PROPOSED DRAINAGE FLOW CONCRETE A/C AIR CONDITIONER S/W SIDEWALK A5M(-- S LJ FR VETI N 0 c&fM APPING INC. CERTIFICATION OF AUTHORIZATION NUMBER LB#6393 3191 MAGUIRE BOULEVARD, SUITE 20 ORLANDO, FLORIDA 32803 (407) 426-7979 WWW.AMERICANSURVEYINGANDMAPPING.COM 1" = 30' GRAPHIC SCALE 0 15 30 PI POINT OF INTERSECTION PC POINT OF CURVATURE PT POINT OF TANGENCY RP RADIUS POINT PRO POINT OF REVERSE CURVATURE PCC POINT OF COMPOUND CURVATURE TYP TYPICAL CS CONCRETE SLAB (P) PER PLAT (C) CALCULATED PB PLAT BOOK PGS PAGES SQ. FT. SQUARE FEET F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY F.I.R.M, FLOOD INSURANCE RATE MAP NAVD NORTH AMERICAN VERTICAL DATUM NGVD NATIONAL GEODETIC VERTICAL DATUM D&UE DRAINAGE & UTILITY EASEMENT POE PRIVATE DRAINAGE EASEMENT PEE PUBLIC UTILITY EASEMENT SURVEYOR NOTES: 1. THE SURVEYOR HAS NOT ABSTRACTED THE LAND SHOWN HEREON FOR EASEMENTS, RIGHT OF WAY, RESTRICTIONS OF RECORD WHICH MAY AFFECT THE TITLE OR USE OF THE LAND 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCATED EXCEPT AS SHOWN. 3. NOT VALID WITHOUT THE AUTHENTIC ELECTRONIC SIGNATURE AND THE AUTHENTIC ELECTRONIC SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. Digitally signed by James W Boleman 01,netax�nainrxrro DN:,—US, ,t—FI.flda, -AMERICANSD RVEYING& MAPPING, INC., —jame, W FOR email =jboIemar@asmcorporate, om Date: 2021.07.12 16:54:40 -04'00' THE Adobe Acrobat yan,j­ 11.0.23 FIRM JAMES W. BOLEMAN PSM# 6485 DATE ! ,' t i '• i ti i i i i i1 ! Permit No. _- - F Parcel ID No f Stateo+► • THE UNDERSIGNED Informatio 9 • ie General Description of Improvement N@Lw_- Owner Informaflon or Lessee Address--'1"�m � 3 637 Interest In Property._ -Eae_ SIrpnip city nip Name of Fee Simple Titleholder, Tif—diff—er—ent—fro—mOMer —11sted above) ,Address 4. Contractor N G Ori ail City State Caty State 5. Surety: •Name Address State Amount of Bond:%,Q CityTelephone No.: g. Lender, 1� Name Address . Gify ' Lender's Telephone No,: S#afa 7, Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713,13(1)(a)(7), Florida Statutes: Address 33637 F� City State Telephone Number of designated Person: $ l 3-°740-97 0 $, In addition to himself, the owner designates of to receive a,00py of the Llenor's Notice as provided in Section 73.13(1.)(b), Florida Statutes, Telephone Number of Person or Entity Designated by Owner: Expiration date of Notice of Commencement (the expiration date may not be before the completion of constructlon and final payment to the contractor, but will be one year from the -date of recording unless a dIfferent date is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRAIION OF THE N0110EOF • ARE CONSIDERED IMPROPER POP P PAYMENTSr P CHAPTER PART FLORIDA STATUTES, 713 AND , RESULT YOUR P PAYING A FOR P IMPROVEMENTS P i! P • M *lit P. A NOTICE UST P P O•DR A M P• M• B !Pi+ P P 4 !a D M 4L AA CONSULT E THE WITH YOUR I FENDER OR AN ATTORNEY 13EFORE CMMENCING WORK OR RECORDNG YOUR NOTICE OF COMMENCEMENT, Under penalty of perjury, I declare that I have read the foregoing fice f commencement and that the facts stated thereln are true to the best i... . edge. and belief, P STATE O FLORIDA CITY OF UILDING ZEPHYRHILLS EPARTMENT "NOTICE" D`3 OF ADDITION OR CORRECTION ADDRESS DATE PE IT THIS JOB HAS NOT BEEN COMPLETED. The following additions or correctians shall be made before the job will be accepted. S It is unlawful for any Carpenter, Contractor, Builder, or other persons, to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered, any part of the work with flooring, lath, earth or other material, until the proper inspector has had ample time to approve 780-0020 FOR REJNSPE�UION the installation. OFFICE HOURS 8:00 AM - 4:30 PM MON.-FRI. INSPECTOR