Loading...
HomeMy WebLinkAbout21-2740City of Zephyrhill s 5335 Eighth Street Zephyrhills, FL 33542 BAR-002740-2021 Phone: (813) 780-0020 Fax: (813) 780-0021 Issue Date: 09/09/2021 REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. I I I I I i � I ' •ii I I•I ♦ ! 111 111111 11 1 . It , 111 4 23131��� Complete Plans, Speccations add fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. WO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNATURE I W"'11.0101 1 5 i M--wN. PEfIT OFFICE() THOUT APPROVED INSPECTION 0 ILI 1-*W rKs"T I INSTR# 2021192026 OR BK10434PG2052 Page 1 of 1 09/09/2021 11:39 AM Rcpt: 2349698 Rec: 10.00 DS: 0.00 IT: 0.00 imau"Olat Permit No. Property Identification No. 24-26-21-0040-00000-1040 THE LTNDERSIONED hereby give informs you that the improvement will be made to certain real property, and in accordance with Section 713.13 of the Florida Statutes, the following information is provided in this NOTICE OF COMMENCEMENT. i.Description of property (kgaldeacrt rlonr ection 24, Township 26 South, Range 21 East a) Street Address:« s , 2.0enend description of improvements: r 3.Owner Information a) Name and addres . ta b) Name and address o fee simple titleholder (if other than owner) c) Interest in property 4.Contractor Information a) Name and addre b) Telephone No.: Fax No. (Opt.) S.Surety Information a) Name and address: b) Amount ofBond:. c) Telephone No.: Fax No: (Opt.) 6.Lender a) Name and address: Phone No. 7. Identity of person within the State of Florida designated by owner upon whom notices or other documents maybe served: a) Name and address: b) Telephone No.: Fax No. (Opt.) $.In addition to himself, owner designates the following person to receive a copy ofthe Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes: a) Name and address: b). Telephone No.: L Fax No (flpt ) 9.Expketion date of Notice of Commencement (the expiration date is one year from the'date of recording unless a different date is specified): FLORIDA NOTICEOF e RECORDED AND POSTED ON r: SITE BEFORE INSPECTION, IF YOU ► TO OBTAIN r YOUR OR r• r• COMMENCING WORK ORRECORDING r r • r r STATE OF r. COUNTY OF PASCO ••or 0 wnees Authodzcd r , ) t' * A .Ir ' R Personally Known Notary signature OR Produced Identification 0111 T . ype of Identification Produced "-W- Name (print) i A e- Under penalties ofpeturY, I declare that I have read the foregoing the facts stated in it am true to the best of my ge and belief. jAcQUELINEBOGES .. .: 813-780-0020 City Of Zephyrhills Permit Application Fax-813-780-0021 Building Department Owner's Name U, t Fee Simple Titleholder Name Fee Simple Titleholder Address CA- Of 4' g -. Owner Phone Number r Owner Phone. Number Owner Phone Numnbar E:::::�� REPAIR ES INSTALL PROPOSED USE TYPE OFtONSTRUCTION BLOCK ,FRAME R1 BUILDING i3tJiLDiNG Ez� ELECTRICAL $ PLUMBING $ MECHANICAL $ GAS ROOFING FINISHED FLOOR ELEVATIONS SIGN DEMOLISH HEIGHT VALIDATION OF TOTAL CONSTRUCTION AMP SERVICE 100 &'t d-7-j PROGRESS ENERGY W.R.E:C. VALUATION OF MECHANICAL INSTALLATION FLOODSPECIALTY = OTHER ZONE aA� g " COMPANY BUILDER SIGNATURE REGISTERED Address ELECTRICIAN s t ' rr> e_1 COMPANY SIGNATURE REGISTERED Address a Z,e"i PLUMBER COMPANY SIGNATURE REGISTERED License Y / N __FEE CURREN Y / N License Y / N FEE'CURREN Y / N'' ' License Y! N FEECl9rdREh Y.hN OTHER COMPANY SIGNATURE REGISTERED Y / N FEE CURREP Y / N Address License # 11111.1I'll 'I1111I'll 111111Ii1`11111ll11IiIrI11,II1111,11111t11II11111I1I I Ii11II RESIDENTIAL Attach (2) PldtPlans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction, Minimum ten (10) working days after submittal date. 'Required onsite, Constructlori Plans, Stormwater Mans w/ Slit Fence installed,. Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1 ) set of Energy Forms. R-O-W Permit for new construction. Minimum ten (10) working days after submittal date. Required:onsite, Construction Plans, Stonnwater,,Plans w/ Slit Fence Installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of°Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement Is required. (AIC upgrades over $7500) ** Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles sewers Service Upgrades A/C Fences (Plot/Survey/Footage) Driveways -Not over Counter if on public roadways -needs ROW` lot improvement requests must be submitted no later than Wednesday by 2:00 to be �4ssed on the following committee meeting day. All permits must be posted visible to the street. )ate Recd LOT IMPROVEMENT REQUEST Permit No ,ro: EPPOA Lot Improvement committee & Board of Directors From Lot#/Address : Phone number where you can be reached:_ #e request EPPOA approval for construction, addition to our installation, on the following: Shed (>41,anai ( )Rv Port ( )Park Model ( ) Cottage ( )Concrete Slab Pavers Concrete Painting ( ) Rv Skirting ( ) Landscaping ( )Pet enclosure other Aal requests for construction/additions/remodeling are required to have a complete, dotailed/sketch,'to include footprint, setbacks, front elevation, back elevation, left right side elevation and top elevation. All elevations must include all sizes and locations of windows and doors, with length, width and height of the overall structure. Park models are to include pamphlet with pictures. In addition, all requests require and must include the full description, including color of siding, trim, shutters, doors, pavers and concrete painting if applicable. "PRIOR TO BEGINNING CONSTRUCTION" a copy of the Zephyrhills building permit and a copy of the completed engineering plans must be RETURNED to the "LOT IMPROVEMENT COMKITTEE'll these will be returned to you for construction. Upon completion of your construction a complete copy of the engineering drawings of the structure, (as built) permits, inspections and final permit approvals must be returned to the Emerald Pointe Lot improvement Committee for Office filing. Pet enclosure must follow guidelines for size, height and location. ALL REQUESTS MUST COMPLY WITH CURRENT REQUIRED PERMITS FROM THE CITY OF ZEPHYRHI� �.FLORIDA CURRENT BUILDING CODES. Comments: . ... ..... ..... . . . .... .. . ....... .. L ar Date Lot Owner's Si Kati �0 5ft Setback /Z O 0 I m 5ft Setback I l A til l,!�oncrete 26' x 63' permit No Lot#--j0(/Ac,&tss: 50 0 '118 -- , --3 wiler. — ; C--/Xk/ 20 ft Setbick from hiside of Cxwb to WIding 15 ft Setback to coacli. I mm"NEWWAMMM owmmmwwwmwmwwmwwwmow 5ft Setback a,.3 2 1- o -S � ff kA Ca 5wj1\1O /- I)o o I General Notes A. CONCRETE & FOUNDATION DESIGN: 1. ALI, CONCRETE GRADE BEAMS AND FOOTINGS SHALL BE 3000 PSI MINIMUM. 2. ALL CONCRETE FILLED SUPPORTED SLABS SHALL BE 2500 PSI MINIMUM, 3 1/2" NOMINAL THICKNESS. 3. 3000 PSI FiBERMESH (3/4" PER CUBIC YARD MIN.) MEETING APPROPRIATE ACI AND ASTM REQUIREMENTS MAY BE USED IN LIEU OF WELDED WIRE MESH 4. ALL SLABS ON GRADE SHALL BE 4" THICK WITH FIBERMESH, TERMITE TREATMENT OF SOIL BENEATH SLAB IS NOT REQUIRED IF SLAB DOES NOT ABUT A WOOD FRAME STRUCTURE. NO WOOD FRAME STRUCTURE MAY BE BUILT ADJACENT TO OR ON TOP OF A SLAB WITHOUT TREATING THE SOIL FOR WOOD DESTROYING ORGANISMS. 5. ALL REINFORCING SHALL CONFORM TO ASTM A615, BE GRADE 60 (60 KSI MIN.) DEFORMED BARS, #3 BARS MAY BE GRADE 40 6. ALL OVER POUR CONCRETE FILLED SUPPORTED SLABS SHALL BE 3000 PSI MIN., 2" MINIMUM. THICKNESS, 7. SOIL BEARING PRESSURE SHALL BE A MINIMUM OF 1500 PSF, 8. THE CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING: OPC (PORTLAND CEMENT TYPE 1,- ASTM C 150). AGGREGATES - #6 STONE, ASTM C 33 SIZE NO. 67 LESS THAN 3/4". AIR ENTRAINING +/- 1%- ASTM C 260. WATER REDUCING AGENT - ASTM C 494. CLEAN POTABLE WATER. OTHER ADMIXTURES SHALL NOT BE PERMITTED. 9. METAL WELDED WIRE SHALL CONFORM TO ASTM A 185. 10. PREPARE & PLACE CONCRETE ACCORDING TO AMERICAN CONCRETE INSTITUTE MANUAL STANDARD PRACTICE, PART 1, 2, & 3 ALONG WITH HOT WEATHER CONDITIONS RECOMMENDATIONS. 11, IF UTILIZING EXISTING CONCRETE FOR FOUNDATION, CONCRETE SHALL BE A MINIMUM OF 4" IN THICKNESS, VISIBLY FREE OF ANY STRUCTURAL EXCESSIVE CRACKING, SPALLING OR OTHER DETERIORATION. ITIO ; ► [ I. CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR 2ALL MORTAR SHALL BE OF TYPE M OR & 3ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE. AGGREGATE SIZE OF 3/8". 4.PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS 5'-0" IN HEIGHT. C. ALUMINUM: 1. ALL STRUCTURAL ALUMINUM SHALL CONFORM TO THE MINIMUM REQUIREMENTS OF 6005-TSFOR ALLOY WITH A MINIMUM THICKNESS OF 0.040" FOR SUPPORTING MEMBERS. 2. WHERE KICK PLATES ARE USED A MINIMUM THICKNESS OF 0,024" SHALL APPLY, 3. STRUCTURAL ALUMINUM DESIGN CONFORMS TO "PART 1-A - SPECIFICATIONS FOR ALUMINUM STRUCTURES - ALLOWABLE STRESS DESIGN" OR "PART 1-B - SPECIFICATIONS FOR ALUMINUM STRUCTURES - BUILDING LOAD AND RESISTANCE FACTOR DESIGN" OF THE CURRENT ALUMINUM DESIGN MANUAL PREPARED BY THE ALUMINUM ASSOCIATION, INC.WASHINGTON D.C. THE FLORIDA BUILDING CODE, 7TH EDITION ( CHAPTER 16 STRUCTURAL DESIGN & CHAPTER 20 ALUMINUM). 4. WHERE ALUMINUM COMES INTO CONTACT WITH STEEL, OR PRESSURE TREATED LUMBER PROVIDE DIELECTRIC SEPARATION. 5, ALUMINUM MEMBERS SHALL BE STITCHED WITH NO LESS THAN #10 SMS 6" FROM THE ENDS AND 12" ON CENTER, IF USING #1.2 SPACING MAY BE 24" ON CENTER. 6. VINYL AND ACRYLIC PANELS SHALL BE REMOVABLE, THEY SHALL BE IDENTIFIED WITH A DECAL ESSENTIALLY STATING "REMOVABLE PANEL SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 MPH" . DECAL SHALL BE PLACED SO IT IS VISIBLE WHEN PANEL IS INSTALLED. D. FASTENERS: L ALL LAG BOLTS SHALL CONFORM TO STAINLESS STEEL TYPE 300 18-8, WITH STANDARD FLAT WASHER UNLESS MANUFACTURER GALVANIZES BOLTS SPECIFIES FOR USE WITH ACQ PRESSURE TREATED WOOD, 2. HEX BOLTS HAS TO BE ASTM A 325, PLATED WITH STANDARD FLAT WASHERS AND NUTS. 3. ALL CONCRETE SCREWS SHALL BE, SIMPSON, HILTI, RAWL, TAPCON, REDHEAD, DYNABOLT, OR APPROVED EQUAL. 4. ALL METAL TIES AND ASSOCIATED ACCESSORIES SHALL BE HOT DIPPED GALVANIZED. S. ALL LAG BOLTS SHALL HAVE A MINIMUM EMBEDMENT OF 8X BOLT DIAMETER INTO STRUCTURAL FRAMING (G=.42 MIN.). 6. LAG BOLTS AND SCREWS INTO WOOD FRAMING SHALL BE PROVIDED WITH PILOT HOLES HAVING A DIAMETER NOT GREATER THAN 70 PERCENT OF THE THREAD DIAMETER OF THE BOLT OR SCREW. ALL LAG BOLTS AND SCREWS SHALL BE INSERTED IN PILOT HOLES BY TURNING AND UNDER NO CIRCUMSTANCES BY DRIVING WITH A HAMMER. 7. ALL EXPANSION ANCHORS SHALL BE DESIGNED IN ACCORDANCE WITH THE SPECIFIC MANUFACTURER'S REQUIREMENTS AND ALLOWABLE LOADS AND SHALL ONLY BE APPLIED IN CONDITIONS ACCEPTABLE TO MANUFACTURER. FASTENERS SHALL BE A MINIMUM OF SAE GRADE #5 OR BETTER ZINC PLATED. ALL FASTENERS CONNECTING ALUMINUM COMPONENTS OR PRESSURE TREATED LUMBER ARE STAINLESS STEEL TYPE :300 18-8, UNLESS MANUFACTURER GALVANIZED BOLTS SPECIFIES FOR USE WITH ACQ PRESSURE TREATED WOOD, OR OTHERWISE NOTED ON PLANS. 9. ALL FASTENERS SHALL COMPLY WITH ASTM A153. 10. ALI.. CONNECTORS SHALL COMPLY WITH ASTM A653 CLASS G-185. 11. FOR SMS, THE MINIMUM CENTER -TO -CENTER SPACING SHALL BE 3/4" AND MINIMUM CENTER -TO -EDGE SHALL BE 1/2" UNLESS NOTED OTHERWISE. E. REFERENCE STANDARDS: ASTM E 119 ASTM E 1300 ASCE 7 -16 AA ASM35, AND SPEC. FOR ALUMINUM PART 1-A, & 1-B ASTM C94 ASTM C150 ASTM C33 ASTM C260 ASTM C494 ASTM A615 ASTM A185 FLORIDA BUILDING CODE (CHAPTERS 16,20 AND 23) 7TH EDITION CURRENT ALUMINUM DESIGN MANUAL F. ABBREVIATIONS: THE FOLLOWING LIST OF ABBREVIATIONS IS NOT INTENDED TO REPRESENT" ALL THOSE USED ON THESE DRAWINGS, BUT TO SUPPLEMENT THE MORE COMMON ABBREVIATIONS. I. TYP -- TYPICAL 2. SIM--SIMILAR 3. DON -- UNLESS OTHERWISE NOTED 4. CONT-- CONTINUOUS 5. VIF -- VERIFY IN FIELD G. RESPONSIBILITY: 1. ALL SITE WORK SHALL BE PERFORMED BY LICENSED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDINANCES, ETC, 2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND DETAILS, NOTIFYING ENGINEER OF ANY DISCREPANCIES BETWEEN DRAWINGS, FABRICATED ITEMS, OR ACTUAL FIELD CONDITIONS. 3. THESE DRAWINGS REPRESENT THE ACCEPTABILITY OF THE 'SUNROOM' ROOM ADDITION ELEMENTS AS PROVIDED BY THE CONTRACTOR. 4. ALL DETAILS ON THESE DRAWINGS ARE ENGINEERED BASED ON INFORMATION PROVIDED BY THE CONTRACTOR AND MANUFACTURER. 5. ANY DETAILS NOT SHOWN ARE TO BE ENGINEERED BY LICENSED P.E. IN ACCORDANCE WITH STANDARD ENGINEERING PRACTICES. H. MISCELLANEOUS: 1. ALUMINUM ADDITIONS ARE NOT TO BE INS'TALI.ED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME WITHOUT A MANUFACTURER'S HOST BEAM. IF NO HOST BEAM IS PRESENT A SEPARATE 4TH WALL SUPPORT SYSTEM SHALL BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME, 2. 1F ENCLOSURE CONTAINS A SWIMMING POOL OR SPA, THE ENCLOSURE SHALL COMPLY WITH RESIDENTIAL SWIMMING BARRIER REQUIREMENTS OF THE FBC 7TH EDITION R 4501.17.1 IN ITS ENTIRETY, 3. DOOR LOCATIONS MAY BE DETERMINED IN THE FIELD BY CONTRACTOR. 4. IF PAVERS ARE UNDER ALUMINUM MEMBERS THEY SHALL HAVE EPDXY ADHESIVE TO CONCRETE OR IF USING GROUT, ENSURE BONDING AGENT IS USED FIRST. S. SCREENING MATERIAL SHALL BE 18X14X0.013 OR EQUIVALENT DENSITY SCREEN MESH ONLY UNLESS NOTED OTHERWISE. 6. EMERGENCY ESCAPE & RESCUE OPENING PER FBC R310.1 SHALL BE VERIFIED BY CONTRACTOR & BUILDING OFFICIAL 7. ENCLOSED ADDITIONS TO MANUFACTURED HOMES SHALL NOT CHANGE THE EXIT FACILITIES FOR EGRESS PER HUD 3280.105, (a) THROUGH (a)(2)(iv), SO THAT THE DISTANCE TO EXIT DIRECTLY OUTSIDE FROM ALL. BEDROOMS IS LESS THAN 3T AND SO THAT TWO EXITS DIRECTLY OUTSIDE ARE STILL MAINTAINED, A CARPORT OR SCREEN ROOM SHALL BE CONSIDERED AS OUTSIDE, NON -HABITABLE SUNROOMS OR HABITABLE LIVING SPACE MAY BE ADDED WHERE AN EXIT DOOR WAS LOCATED, AS LONG AS A NEW EXIT DOOR IS ADDED AND MEETS TIME REQUIREMENTS OF HUD 3280.105 DESIGN DATA: 1. RISK CATEGORY: 2. ULTIMATE DESIGN WIND SPEED Vult, (3 SECOND GUST): 140 MPH NOMINAL DESIGN WIND SPEED Vasd: 110 MPH 1 WIND EXPOSURE: B 4. WIND LOADS - ENCLOSED: INTERNAL PRESSURE COEFFICIENT: +/-OA8 COMPONENT & CLADDING PRESSURES: ROOF: ZONE 1: 14.3/-56.2 WALLS: ZONE 4: 35.3/-38.2 ZONE 2: 14.3/-74.1 ZONE 5: 35.3/-47.2 ZONE 3: 14.3/-1.01,0 SOLID ROOF (MWFRS): 23 PSF FACTOR APPLIED FOR ALLOWABLE STRESS DESIGN: .6 5. SOLID ROOF TYPE: 3"X48"X.024", 1 LB. DENSITY EPS FOAM COMPOSITE PANEL ROOF, FL 7561 OR EQ. DEFLECTION: L / 120 MAXIMUM ALLOWABLE SPAN: 13.00` SITE SPECIFIC DESIGN SPAN: 6.50' 6. 4" CONCRETE SLAB PER SECTION 'A' OF GENERAL NOTES AND CONCRETE FOOTING PER DETAIL. EXISTING CONCRETE SHALL BE ADEQUATE TO WITHSTAND THE LOADS FROM THE. PROPOSED ADDITION HOLLOW SECTIONS INDEX: 2 x 2:---------------------------------------2" x 2" x 0.044" S-1 GENERAL NOTES 3 x 2:-------------------------------------3" x 2" x 0.050" S-2 DRAWING S-3 DRAWING 2 x 3:---------------------------------------2" x 3" x 0.050" S-4 DRAWING 2 x 3:---------------------------------------2" x 3" x 0.070" S-5 DETAILS 2 x 4:---------------------------------------2" x 4" x 0.050" S-6 DETAILS 2 x 5:---------------------------------------2" x 5" x 0.050„ S-7 DETAILS 1 x 2:---------------------------------------- 1" x 2" x 0.040" 1 x 3:---------------------------------------1" x 3" x 0.045„ SNAP SECTIONS 2 x 2 Snap: ---------------------------------- 2" x 2" x 0.045" 2 x 3 Snap:---------------------------------2" x 3" x 0.050" 2 x 4 Snap:--------------------------------- 2" x 4" x 0.045" ►N ur "Wilvewfiraff 2 x 4 SMB:---------------------- 2" x 4" x 0.044" x 0.1.00" 2 x 5 SMB:---------------------- 2" x 5" x 0.050" x 0.118" 2 x 6 SMB:---------------------- 2" x 6" x 0.050" x 0.120" 2 x 7 SMB:---------------------- 2" x 7" x 0.057" x 0.120" 2 x 8 SMB:---------------------- 2" x 8" x 0.072" x 0,224" 2 x 9 SMB:---------------------- 2" x 9" x 0.072" x 0.224" 2 x 10 SMB:------------------- 2" x 10" x 0.092" x 0.374" I HEREBY CERTIFY THAT I HAVE REVIEWED THIS PLAN AND FOUND IT TO BE IN COMPLIANCE WITH ASCE 7-16 AND FBC 7TH EDITION RESIDENTIAL & EXISTING PROFESSIONAL ENGINEER SEAL ENGINEER OF RECORD David W. Smith P.E. FLORIDA LICENSE NUMBER: 53608 Thomas L. Hanson RE, FLORIDA LICENSE NUMBER: 38654 Myron Max Neal, P.E. FLORIDA LICENSE NUMBER: 86663 Joel Falardeau P.E. FLORIDA LICENSE NUMBER: 70667 Erik Stuart P.E. FLORIDA LICENSE NUMBER: 7760S FBC Plans & Engineering Services, Inc. 6272 Abbott Station Drive Unit 101 Zephyrhills, fl. 33542 Phone: (813)788-5314 Fax: 1-(866)-824-7894 Website: www.fbcplans.com email: e-b@fbcptans.com DRAWN BY: W.P. DATE: 8/10/21 REVISION: DATE: Ro 1 RO 2 RO 3 RO 4 #21_0722_322 PROJECT ADDRESS: IRENE GRIMWOOD-BORTON 3502 ALABASTER DR. EMERALD POINTE RV ZEPHYRHILLS, FL 33540 CONTRACTOR: OWNER ►1 f CONCRETE r 5 FOOTINGWIT 2"X4" P.T. STUD WALLS /- FINISHED WITH VINYL SIDING 33'-0" g°_0 15°-6" 48X72 HS______ 11 +---------------------' FAN !!J22O E I I � iii m iii I I I I Ed I v1 !if = I ---------------------------------------------------------- �a I 0) N fit -- ---- III - ---------------------------------------------- ---- ----- - ------------------------------------------------------ 2X9 RIDGE BEAM i O X I cv I M a0 X I I i I f F i f I T � I I sib 11 I GO I---------- -------------------------{-14 ----------- ------ -- ----------------- ---------------- —G I 48X72 HS III I 15'-6" 1'-0" 1'-0. 9'-0. 16'-6" 16'-6" 42'-0" 110 V. OUTLET SURFACE MOUNTED uaaT FIXTURE FLOOR PLAN N EXISTING CONCRETE SLAB 1/4"=1'-011 FOR RV PARKING I HEREBY CERTIFY THAT I HAVE REVIEWED THIS PLAN AND FOUND IT TO BE IN COMPLIANCE WITH ASCE 7-16AND FBC 7TH EDITION RESIDENTIAL & EXISTING PROFESSIONAL ENGINEER SEAL ENGINEER OF RECORD David W. Smith P.E. FLORIDA LICENSE NUMBER: 53608 Thomas L. Hanson P.E. FLORIDA LICENSE NUMBER: 38654 Myron Max Neal, P.E. FLORIDA LICENSE NUMBER:86663 Joel Falardeau P.E. FLORIDA LICENSE NUMBER: 70667 Erik Stuart P.E. FLORIDA LICENSE NUMBER: 7760S FBC Plans & Engineering Services, Inc. 6272 Abbott Station Drive Unit 101 Zephyrhills, fl. 33542 Phone:(813)788-5314 Fax: 1-(866)-824-7 B94 Website: www.fbcplans.com C.O.A. - i#29054 DRAWN BY: W.P. DATE: 8/10/21 REVISION: DATE: RO 1 RO 2 RO 3 RO 4 #210722322 PROJECT ADDRESS: •- PLAN/ELEVATIONS S-2 NEW CCINCRE, SLAB AND 12"x12" FOOTING LB. DENSITY El FOAM COMPOSITEPANEL ROOF, FL 7561OR 1 /4"=1 '-0" 1 FRONT ELEVATION STUDS @ • O.C. FINISHED WITH VINYL SIDING. IiEE WALL SECTIONFOR k;; Oil NOTE I HEREBY CERTIFY THAT I HAVE REVIEWED THIS PLAN AND FOUND IT TO BE IN COMPLIANCE WITH ASCE 7-16 AND FBC 7TH EDITION RESIDENTIAL& EXISTING PROFESSIONAL ENGINEER SEAL ENGINEER OF RECORD David W. Smith P.E. FLORIDA LICENSE NUMBER: 53608 Thomas L. Hanson P.E. FLORIDA LICENSE NUMBER: 38654 Myron Max Neal, P.E. FLORIDA LICENSE NUMBER: 86663 Joel Falardeau P.E. FLORIDA LICENSE NUMBER: 70667 Erik Stuart P.E. FLORIDA LICENSE NUMBER: 77605 FBC Plans & Engineering Services, Inc. 6272 Abbott Station Drive Unit 101 Zephyrhilis, fl. 33542 Phone:(813)788-5314 Fax: 1-(866)-824-7894 Website: www.fbcplans.com C.O.A. - #29054 DRAWN BY: W.P. DATE: 8/10/21 REVISION: DATE: RO 1 RO 2 RO 3 RO 4 PLAN/ELEVATIONS 3"X48"X.024" 1 LB. DENSITY EPS FOAM COMPOSITE PANEL ROOF, FL 7561 OR EQ. I�Ti7�i_7i�ir3Zf LEFT SIDE ELEVATION 1 /4"=1 '-0" DOUBLE 2X9 CARRIER BEAM, SEE DETAIL ol� w o, 0 0 4 10'-0" 42'-0" STUDS Ct • O.C. SIDING.FINISHED WITH VINYL SEE WALL SECTION OR P.T. PLYWOODO RIGHT SIDE ELEVATION NEW CONCRETE —' SLAB AND 12"X12" 1 /4"=1'-0" FOOTING I HEREBY CERTIFY THAT I HAVE REVIEWED THIS PLAN AND FOUND IT TO BE IN COMPLIANCE WITH ASCE 7-16 AND FBC 7TH EDITION RESIDENTIAL & EXISTING PROFESSIONAL ENGINEER SEAL ENGINEER OF RECORD David W. Smith P.E. FLORIDA LICENSE NUMBER: 53608 Thomas L. Hanson P.E. FLORIDA LICENSE NUMBER: 38654 Myron Max Neal, P.E. FLORIDA LICENSE NUMBER: 86663 Joel Falardeau P.E. FLORIDA LICENSE NUMBER: 70667 Erik Stuart P.E. FLORIDA LICENSE NUMBER: 77605 FBC Plans & Engineering Services, Inc. 6272 Abbott Station Drive Unit 101. Zephyrhilis, Fl. 33542 Phone:(813)788-5314 Fax:1-(866)-824-7894 Website: www.fbcptans.com C.O.A. - 929054 DRAWN BY: W.P. DATE: 8/10/21 REVISION: DATE: RO 1 RO 2 RO 3 RO 4 PLAN/ELEVATIONS ALUM RIDGE CAP W/ #10X 5/8" SMS ALUM. BEAM ATTACHMENT TO WALL FRAMING 3"X.125" HEADER W/2"X2"X_125" ANGLES. FASTEN ANGLES TO W/#12X3 4" @ 12" O.C. STUDS W/(4) 1/4"OX3" LAG SCREWS. FASTEN TOP & BOTT�M INTO ROOF 2X SMB TO ANGLE W/#12X3/4" SMS, 1 SCREW PER INCH OF BEAM HT. #8X1/2" TO ATTACH FLASHING TO ROOF ALTERNATE CONNECTION PANEL @ 12" O.C. W/RECEIVING CHANNEL, SEE BEAM TO WALL DETAIL SIMPSON SP2 OR EQUIV. �— 2X DOUBLE TOP PLATE (4) 2X4 STUDS 2X ALUM. RIDGE BEAM FOR BEAM ATTACHMENT FASTEN SCUDS W/16d NAILS @ 12" O.C. EA. SIDE, STAGGERED SIMPSON DSP, SSP OR EQUIV. PLATE TIES, FASTEN PER MANUF. INSTALLATION INSTRUCTIONS SIMPSON LSTA18 OR EQUIV. TYP. @ EA. STUD TO HEADER CONNECTION DBL. 2X HEADER OVER DOOR -I OPENING, SEE PLAN (2) SIMPSON LSTA18 FASTENED PER MANOR SPECS 2X9 ALUM. RIDGE BEAM FASTEN COMPOSITE PANEL TO BEAM WITH #12 TEK SCREW AND 1-1/4"0 NEOPRENE WASHER AT 8" O.C. (USE SCREW LENGH EQUAL TO COMPOSITE PANEL THICKNESS PLUS 1" MIN.) 3" COMPOSITE; PANELS FASTENED TO TOP PLATE W/1/4"O LAG SCREWS W/NEOPRENE WASHERS, 1-1/2" MIN. EMBEDMENT @ 8" O.C. DBL 2"X4" TOP PLATE (ONLY NON -TREATED WOOD IN CONTACT W/ALUM. ROOF OR PROVIDE IMPERVIOUS MOISTURE BARRIER) DBL. 2X READER WITH 1/2" Phi WOOD SPACER OVER OPENINGS, SEE HEADER TABLE METAL FLASHING/CAULK OVER DOOR OPENINGS VINYL SIDING OF CHOICE APPLIED PER MFG'S SPECS. 7/16" OSB SHEATHING (FROM 24"ABOVE FIN. FLOOR) 1/2" COX P.T. PLYWOOD TO 24" ABOVE FINISHED FLOOR SHEATHING SHALT.. OVERLAP BOTTOM AND TOP PLATES. (SEE NAILING NOTE). 2"X4" P.T. STUDS @ 16" O.C. 2X4 P.T. BASE PLATE 1/2"0 WEDGE ANCHORS W/STANDARD WASHERS, 1.2" FROM CORNERS, 6" FROM OPENINGS AND 24" O.C. WITH 4" MIN. EMBEDMENT AND 1-3/4" MIN, EDGE DISTANCE TYP. CONCRETE BELOW GRADE PER R403.1.4 2 #5 REBAR CONT. ON 3" HIGH CHAIRS HEADERS 0 BEARING WALL. f SIZE SPAN IV ,JACK STUDS SUPPORTING COMP. PANEL ROOF (2) 2"x4" 4'-4" 1 2 2"xs" 6°-4" 1 (2) 2"XB" 8'-0" 2 (2) 2"x10" 9'-6" 2 (2) 2"x12" 1 1 V-6" 3 DBL. HEADERS W/7' PLWD. SPACER, GLUED & NAILED W/2 ROWS OF 12d NAILS STAGGERED @ 12" O.C. EACH FACE -PRODUCT APPROVAL CODE CHART STRUCTURAL COMPONENTS SIMPSON SPT SP2 FL10456 'SIMPSON H10A FL10456 SIMPSON DSP FL10456 SIMPSON SPH FL10456 SIMPSON ABU ABW FL10860 SIMPSON LSTA MSTA FL10456 SIMPSON CS16 FL10458 METAL FLASHING OR OTHER APPROVED FLASHING MATERIAL SHALL BE APPLIED OVER DOOR & WINDOW OPENINGS TO PREVENT WATER PENETRATION INTO THE WALL CAVITY OR STRUCTURAL FRAMING COMPONENTS, PER R703.4 WOOD SIDING, SHEATHING AND WALL FRAMING ON THE EXTERIOR OF A BUILDING HAVING A CLEARANCE OF LESS THAN 6" FROM THE GROUND SHALL BE PRESERVATIVE TREATED PER FBC SECTION 317.1.5 WALL PANELS (PLYWOOD) NAILING NOTE: NAIL 8d NAILS 6" O.C. @ EDGES & 12" O.C. IN FIELD. ROWS OF NAILS SHALL BE 7" MIN. FROM PANEL EDGES. PLYWOOD SHEATHING SHALL OVERLAP BOTH TOP & BOTTOM PLATES. ALL FASTENERS NAILED PER MFG.'S SPECIFICATIONS. SIMPSON SP2 OR H2.5A PLATE TIE OR EQUIV 2X BLOCKING FOR PANEL SPLICE WHERE WALL HT, EXCEEDS PANEL LENGTH INSTALL WINDOW FOLLOWING MANUF. INSTALLATION INSTRUCTIONS NOTE: VINYL SIDING MUST BE INSTALLED OVER A MINIMUM 7/16" WOOD STRUCTURAL PANEL SHEATHING (PLYWOOD OR OSB) WITH AN APPROVED WEATHER RESISTIVE BARRIER PLACED UNDER THE SIDING. SIMPSON SP1 PLATE TIE, OR EQUIVALENT 4" CONCRETE SLAB & 1.2"X12" FOOTING, PER SECTION A OF GENERAL NOTES cV 12" WALL SECTION I HEREBY CERTIFY THAT I HAVE REVIEWED THIS PLAN AND FOUND IT TO BE IN COMPLIANCE WITH ASCE 7-16 AND FBC 7TH EDITION RESIDENTIAL & EXISTING PROFESSIONAL, ENGINEER SEAL ENGINEER OF RECORD David W. Smith P.E. FLORIDA LICENSE NUMBER: 53608 Thomas L. Hanson P.E. FLORIDA LICENSE NUMBER: 38654 Myron Max Neal, P.E. FLORIDA LICENSE NUMBER: 86663 Joel Falardeau P.E. FLORIDA LICENSE NUMBER: 70667 Erik Stuart P.E. FLORIDA LICENSE NUMBER: 77605 FBC Plans & Engineering Services, Inc. 6272 Abbott Station Drive Unit 101 Zephyrhills, fl. 33542 Phone:(813)788-5314 Fax: 1-(866)-824-7894 Website: www.fbcplans.com C.O.A. - #29054 I DRAWN BY: W.P. I DATE: 8/10/21 REVISION: DATE: RO 1 RO 2 RO 3 RO 4 #210722322 PROJECTADDRESS: IRENE f i BOR i ALABASTER3502 D' EMERALD POINTE RV ��7 0 2X4 DOUBLE TOP PLATE SIMPSON RSP4, LSTA12, SP2 OR EQUIV. @ EACH STUD 7/16" OSB OR 1/2" PLYWOOD SHEATHING, SEE NAILING NO SIMPSON LSTA12 OR EQUIV. THESE LOCATIONS 2X4 JACK STUDS PER CHAR` 2X4 FULL LENGTH/KING STUD; PER CHART ATTACH JACK TO CONT, STUI W/16d NAILS @ 16" O.C. 2) DE PL `E INSTALL DOORS IN OPENING PER MANU , INSTALLATION INSTRUCTIONS 6'-0" 1/2"0 WEDGE ANCHORS W/STANDARD WASHERS, 12" FROM CORNERS, 6" FROM OPENINGS AND 24" O.C. W/4" MIN. EMBEDMENT TYP. .4 CRIPPLE STUDS @ 16" Q.C. L 2X HEADER W/1/2" CWOOD SPACER, PER CHART ?X4 STUDS @ 16" O.C. PRES. TREATED) ;IMPSON SP2 OR EQUIV. 2X4 BASE PLATE LSIMPSON DSP, SPH SSP OR EQUIV. @ STUDS TO BASE PLATE DOUBLE 2X4 TOP PLATE DOUBLE 2X WOOI HEADER, SEE CHA 2X4 JACK S1 ATTACH JACK TO COP STUD W/10d NAILS C O.C. %6" OSB SHEATHING NAILING NOTE PRODUCT APPROVAL CODE CHART STRUCTURAL COMPONENTS -. _.._ SIMPSON SP1 SP2 FL10456 SIMPSON H410A FL10456 FL104- SIMPSDN DSP 56 SIMPSON SPH FL10456 SIMPSON ABU ABW FL10860 SIMPSON LST META FL10456 SIMPSON CS16 F'L10456 SIMI EQU 2X4 RT INS UD MFI INS T. 16" SEE 2X, (PF SIM'. AT STUDS DSP OR EQUIV. @ @ STUDSS TO BASE PLATE 1./2" 0 WEDGE ANCHORS W/STANDARD WASHERS, 12" FROM CORNERS, 6" FROM OPENINGS AND 24" D.C. W/4" MIN. EMBEDMENT TYP. WALL FRAMING FOR WINDOW OPENINGS METAL FLASHING OR OTHER APPROVED FLASHING MATERIAL SHALL BE APPLIED OVER DOOR & WINDOW OPENINGS TO PREVENT WATER PENETRATION INTO THE WALL CAVITY OR STRUCTURAL FRAMING COMPONENTS, PER R703.4 WOOD SIDING, SHEATHING AND WALL FRAMING ON THE EXTERIOR OF A BUILDING HAVING A CLEARANCE OF LESS THAN 6" FROM THE GROUND SHALL BE PRESERVATIVE TREATED PER FBC SECTION 317.1.5 HEADERS 0 BEARING WALL e s SIZE SPAN 'W' JACK STUDS (2) 2"x4" 4'-4" 1 2 2N6" 6'-4" 1 (2) 2"x8" 8'-0" 2 (2) 2"00" 9'-6" 2 (2) 2"x12" 1 V-13" 3 DBL. HEADERS W/71" PLWD. SPACER, GLUED & NAILED W/2 ROWS OF 12d NAILS STAGGERED @ 12" O.C. EACH FACE SON RSP4, LSTA12, SP2 OR V. @ EACH STUD RIPPLE STUDS @ 16" O.C. FALL WINDOW IN OPENING PER �R INSTALLATION ('RUCTIONS CRIPPLE STUDS @ 16" O.C. ES. TREATED) `SON SP1 OR EQUIV. OP & BOTTOM OF STUD, TYP. I HEREBY CERTIFY THAT I HAVE REVIEWED THIS PLAN AND FOUND IT TO BE IN COMPLIANCE WITH ASCE 7-16 AND FBC 7TH EDITION RESIDENTIAL & EXISTING PROFESSIONAL ENGINEER SEAL ENGINEER OF RECORD David W. Smith P.E. FLORIDA LICENSE NUMBER: 53608 Thomas L. Hanson P.E. FLORIDA LICENSE NUMBER: 38654 Myron Max Neal, P.E. FLORIDA LICENSE NUMBER: 86663 Joel Falardeau P.E. FLORIDA LICENSE NUMBER: 70667 Erik Stuart P.E. FLORIDA LICENSE NUMBER: 77605 FBC Plans & Engineering Services, Inc. 6272 Abbott Station Drive Unit 101 Zephyrhills, fl. 33542 Phone:(813)788-5314 Fax: 1-(866)-824-7894 Website: www.fbcplans.com C.O.A. - 429054 DRAWN BY: W.P. DATE: 8/10/21 REVISION: DATE: t 0 ' f 1 l'_ we ATTACH ALUM. BEAM TO WOOD W W/RECEIVING CHANNEL SEE BEAN WALL DETAIL 2X4 WOOD STUDS @ 16' ADD 2X4 WOOD STUD BLOCKIP AROUND STUD WALL FRAMIN( BEAM ATTACHMENT #10 X3 4" TO ATTACH FLA RING TO ROOF PANEL @ 12" O.C. ?X9 SMB RIDGE BEAM X4X.125° ALUM KINGPOST FASTEN COMPOSITE PANEL TO BEAM WITH #12 TEN SCREW AND 1-1/4" O NEOPRENE WASHER AT 8" O.C. (USE SCREW LENGH EQUAL TO COMPOSITE PANEL THICKNESS PLUS 1" MIN.) (4) 3/8" THROUGH BOLTS, WASHERS & NUTS 3"X0.125" HEADER ATTACHED TO TOP & BOTTOM INTO ROOF W/412X 3/4", 12" O.C. SMB RIDGE BEAM 4X41125" ALUM KINGPOST i U U i 3/8" THROUGH BOLTS, WASHERS & NUTS d DOUBLE 2X9 SMB CARRIER BEAM 1 1 ( I ROOF BEAM TO CARRIER BEAM USING KING POSTS 4X4 ALUM. KINGPOST 2"X4"X'BEAM HEIGHT RO60° MIN. RECEIVING Uj CHANNEL 1z"U _ #12X%" TEKS @24" O.C. 2 ROWS STAGGERED, TOP & BOTTOM AS SHOWN DOUBLE 2X SMB o U PER PLAN FASTEN REC. CHANNEL TO STRUCTURAL WALL MEMBER W//4"OX2" LAG SCREWS, 1 PER 2 INCHES ______ 4°112X.125" ALUM. PLATE CONNECTED TO OF BEAM HEIGHT, STAGGERED EACH SIDE ______ DOUBLE BEAM & POST. FASTEN PLATE TO POST & DOUBLE BEAM W/(3) %8" CORR. RESISTANT FASTEN BEAM TO CHANNEL THROUGH -BOLTS INTO POST MIN. AND (3) %" 3:W/#10X%4" SMS, 1 SCREW PER INCH MIN. BOLTS INTO THE DEL. BEAM 0 - OF BEAM HEIGHT, EACH SIDE � o m rn DBL. 2X9 SMB CARRIER BEAM DOUBLE BEAM CONNECTION/FASTENING TO 4X4X.125" KINGPOST SCALE:NTS I HEREBY CERTIFY THAT I HAVE REVIEWED THIS PLAN AND FOUND IT TO BE IN COMPLIANCE WITH ASCE 7-16 AND FBC 7TH EDITION RESIDENTIAL & EXISTING PROFESSIONAL ENGINEER SEAL ENGINEER OF RECORD David W. Smith P.E. FLORIDA LICENSE NUMBER: 53608 Thomas L. Hanson P.E. FLORIDA LICENSE NUMBER: 38654 Myron Max Neal, P.E. FLORIDA LICENSE NUMBER: 86663 Joel Falardeau P.E. FLORIDA LICENSE NUMBER: 70667 Erik Stuart P.E. FLORIDA LICENSE NUMBER: 77605 FBC Plans & Engineering Services, Inc. 6272 Abbott Station Drive Unit 101 Zephyrhills, fl. 33542 Phone:(813)788-5314 Fax: 1-(866)-824-7894 Website: www.fbcplans.com email: erb@fbcplans.com DRAWN BY: W.P. DATE: 8/10/21 REVISION: DATE: RO 1 RO 2 RO 3 RO 4 RIDGE BEAM CONNECTION DETAILS S-7