HomeMy WebLinkAbout21-3035 (2)5335 Eighth Street Zephyrhills, FL 33542 Phone: (813) 780-0020 Fax: (813) 780-0021 IS MM BGC-003035-2021 Issue Date: 10/15/2021 REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. SIGNATURE PEJAIT OFFICEC) rk"WE =09 MONX ISM-7 III : 1 .1 [LOA SNAPNRACK RL UNIVERSAL SPEEDSEAL TRACK COMPOSITION ROOF MOUNTING 0 5(16'S.S. LAG SCRE EMBED 0 5116" LAG SCREW 2-1/2' INTO THE ROOF STRUCTURAL MEMBER I RAFTER FOR TORQUE SPECIFICATIONS SEE INSTALLATION MANUAL WASHER 0 5/16"S.S. LAG SCREW FOAM GASKET 2-1/2" MINIMUM EMBEDMENT WASHER soN Sri ... 82g,2 % tad t tT" ,ot -,ATE 0 Sa4,", ROOF RAFTER ITYP.) ROOF ATTACHMENTS SHALL BE EMBEDDED INTO ROOF RAFTERS OR OTHER STRUCTURAL MEMBERS REVISION: .L 11/11921S NEW DETAIL 130P _aLL416L NLW109 DR cliftir"f% M019EER ADDRESS SPEEDSEAL TRACK EC13007964 Brown, Slatef Fort Professional ral Engineer, Lila ROOF DECKING _r ROOFING This iterri has MATERIAL been electronically PILOT HOLE signed and sealed CENTER OF COURSE by Jason Brown, PE on 12f22J2D using a Digital ROOF SHEATHING, UNDERLAYMENT, 2-112"MIN, EMBEDMENT Signature. AND ROOFING MATERIALINTO RAFTER OR (TYP,) Printeri Digitally Signed: 12122/20 STRUCTURAL MEMBER t fflis docunient are not considered signed and sealed DESIGNER: (415) 58MQ20 ex COMPLETED INSTA;= DOMINGO VILLARUEL code must be SHEET verified on eisaronic iss DETAIL A SPEEDSEAL TRACK COMPLETED INSTALLATION SHOULD BE INSTALLED PARALLEL TO RAFTER SECTION VIEW ROOFING MATERIAL — f ML I Sunfun South LCC llX%_'LJr_fMIL R A 12JI11=20 DESIGNER: DAYAN NURSER: , [DESCWTIOM PART 'UN REV� _V. F CI DRAFTER: =RS 36 RL UNI*RSAL, ATTMACHMENT DE-wL, MOUNT &PETE §01!j REV: A 12118=20 DATE: NT p I TT APPROVED BY: W.ARBucKLE 7/712020 SPMEEDS�EAL TRACK ON COMPP PAGE SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS — PAGE # DESCRIPTION • SYSTEM SIZE: 9860W DC, 6960W AC • ALL WORK SHALL COMPLY WITH 2020 FBC (7th Ed.) Amendments to 2018 SOLAR MODULES PV-1.0 COVER SHEET • MODULES: (29) HANWHA Q-CELLS: Q.PEAK DUO BLK-G6+ IRC/IBC/IEBC, MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND SERVICE ENTRANCE 340 INSTALLATION INSTRUCTIONS. ED p1_____ ___Ql PV-2.0 SITE PLAN • INVERTERS: (29) ENPHASE ENERGY: IQ7-60-2-US • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017. • RACKING: SNAPNRACK RLU-1 RL UNIVERSAL, SPEEDSEAL MP MAIN PANEL PV-3.0 LAYOUT TRACK ON COMP, SEE DETAIL SNR-DC-00436 • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 201T PV-4.0 ELECTRICAL - PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLID SUB -PANEL SNR MOUNT SOLIDLY 1 PV-5.0 SIGNAGE —L— SNR MOUNT & SKIRT GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35. • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. PV LOAD CENTER CHIMNEY • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. FQ SUNRUN METER ATTIC VENT • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. IS-1 FLUSH ATTIC VENT • SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE 1, OR TYPE 11 s DEDICATED PV METER MODULES, ARE CLASS A FIRE RATED. IC" PVC PIPE VENT - RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL [INV] INVERTER(S) METAL PIPE VENT CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). >1, 'S I " T-VENT • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). AC AC DISCONNECT(S) SATELLITE DISH • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. DC DC DISCONNECT(S) FIRE SETBACKS 10.52 AMPS MODULE SHORT CIRCUIT CURRENT. • 16.43 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (a) & 690.8 (b)]. CB IQ COMBINER BOX L HARDSCAPE INTERIOR EQUIPMENT — PL— PROPERTY LINE L -1 SHOWN AS DASHED SCALE: NTS A AMPERE sunrun AC ALTERNATING CURRENT AFCI ARC FAULT CIRCUIT INTERRUPTER ENGINEER ADDRESS 225 BUSH ST, SUITE 1400 AZIM AZIMUTH SAN FRANCISCO.CA 94104 VICINITY MAP COMP COMPOSITION P 949-383-0993 DC DIRECT CURRENT EC13007964 (E) EXISTING 5208 TAMPA W BLVD, TAMPA, FL 33634 PHONE ESS ENERGY STORAGE SYSTEM FAX 0 EXT EXTERIOR 6aINT INTERIOR CUSTOMER RESIDENCE: 3 EW MAG MAGNETIC HALEY CARPENTER MSP MAIN SERVICE PANEL 39018 5TH AVE, ZEPHYRHILLS, (N) NEW FL,33542 NTS NOT TO SCALE 001 -3 5th Av�el TEL. (727) 741-0146 4 Ze '4 Oc ON CENTER APN/TMK #: APN: ST-FAB ATE, OF a 0 '4 PRE PRE -FABRICATED 12-26-21-0030-00300-0010 PSF POUNDS PER SQUARE FOOT 6, PHOTOVOLTAIC P802RROJECT NUMBER: -018CARP A L RSD RAPID SHUTDOWN DEVICE ow-ll' .................... ­­,, TL TRANSFORMERLESS S�5vo 21 STRUCTURAL ONLY P DESIGNER: (415) 580-6920 ex3 " TYP TYPICAL Signed: 10/05/21 V VOLTS JASON DITTMAN W WATTS SHEET REV NAME DATE COMMENTS COVER SHEET REV:A 02-10-2021 -PAGE SITE PLAN - SCALE = 1/16" = V m IVAEW o 849 � 'A, STATE OF o" tORK);—N /ONAL O�\\ //0111111110,\ Signed: 10/05/21 (E) FENCI PIL PIL PL Big= I WAIll sunrun ENGINEER ADDRESS 225 BUSH ST, SUITE 1400 SAN FRANCISCO, CA 94104 P: 949_383-0993 EC13007964 5208 TAMPA W BLVD, TAMPA, FL 33634 PHONE FAX 0 CUSTOMER RESIDENCE: I i HALEY CARPENTER 39018 5TH AVE, ZEPHYRHILLS, FL,33542 TEL. (727) 741-0146 APN/TMK #: APN: 12-26-21-0030-00300-0010 DESIGNER: (415) 580-6920 ex3 JASON DITTMAN SHEET SITE PLAN REV: A 02-10-2021 PAGE PV-2.0 I ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Detail Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD: 3 PSF Span Spacing OC Spacing Overhang OC Spacing Overhang SNOW LOAD: 0 PSF RL UNIVERSAL, SPEEDSEAL TRACK ON WIND SPEED: AR-01 COMP SHINGLE - RLU 1-Story 2X6 RAFTERS 11'- 11" 24" COMP, SEE DETAIL SNR-DC-00436 6'- 0" 2'- 4" NA NA STACKED 138 MPH 3-SEC GUST. S.S.LAG SCREWS: AR-02 COMP SHINGLE - RLU 1-Story 2X6 RAFTERS 11'- 11'1 24" RL UNIVERSAL, SPEEDSEAL TRACK ON 6'- 0" 2'- 4" NA NA STACKED 5/16": 2,5" MIN EMBEDMENT S.S. COMP, SEE DETAIL SNR-DC-00436 LAG SCREWS: 5/16": 2.5" MIN EMBEDMENT DI - AR-01 - SCALE: 1/8" = V-13" STRUCTURAL NOTES: PITCH: 14' INSTALLERS SHALL NOTIFY AZIM: 181' ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES 64' 40'-4" OBSERVED PRIOR TO PROCEEDING W1 INSTALLATION. T_ ---- 1-6" IF ARRAY (EXCLUDING SKIRT) --- 6TYP IS WITHIN 12" BOUNDARY 8'-5" REGION OF ANY ROOF PLANE 6'- 11 - -------- EDGES (EXCEPT VALLEYS), 3'-6" t 10'-3" THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12" BOUNDARY REGION ONLY AS FOLLOWS: 2'11" ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED BY 46- 1 50% L 7" ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 115TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS D2 - AR-02 - SCALE: 1/8" = V-0" PITCH: 14' AZIM: 1' S tom n 1"u n ENGINEER ADDRESS 225 BUSH ST, SUITE 1400 SAN FRANCISCO, CA 94104 P 949-383-0993 1'6" EC13007964 24'— 5208 TAMPA W BLVD, TAMPA, FL 33634 PHONE T_ FAX 0 4'-8" CUSTOMER RESIDENCE: . -----..-..-__..---.._.__.______.YE E IV HALEY CARPENTER 39018 5TH AVE, ZEPHYRHILLS, 84FL,33542 4 -10" �B_ 6' TEL. (727) 741-0146 ; �-6'TYP, APN/TMK #: APN: STATE Of 0 12-26-21-0030-00300-0010 PROJECT NUMBER: T-4" ' NAL 802R-018CARP _A_ I Signed: 10/05/21 DESIGNER: (415) 580-6920 ex3 JASON DITTMAN 25'-8" SHEETLAYOUT REV: A 02-10-2021 SEE SITE PLAN FOR NORTH ARROW PAGE PV-3.0 120/24OVAC SINGLE PHASE SERVICE KXETER#: DUKE ENERGY 4363832 UTILITY GRID SUPPLY SIDE TAP AC COMBINER BOX WITH INTEGRATED EXISTING 100A (N) LOCKABLE 10A ENVOY BREAKER MAIN BREAKER BLADE TYPE 3CX-IQ-AMI-240-3C FUSED AC DISCONNECT EXISTING TN' 11-11 A MAIN llj FACILITY PANEL 40A FUSES LOADS FACtLITY GROUND SQUARE D 20A BREAKER [A] FD222NRB 20A BREAKER [B] CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 0 NONE NONE NONE (1) 8 AWG BARE COPPER I NONE (2) 12 AWG PER ENPHASE Q CABLE BRANCH NONE (1) 8 AWG BARE COPPER � (28) HANVVHAD'CELLS: 0.PEAKDUO BLK�5 �0 MODULES AND ' M|CRO'/NVERTERPA|RG (2S)ENPHAGEENERGY: |O7-60-2-US _ (1) BRANCH OF (15) MICRO -INVERTERS [A] | (1)BRANCH 0F(14) MICRO -INVERTERS [B] NA/ No MODULE CHARACTERISTICS BLK-80+340: 340VV ~ OPEN CIRCUIT VOLTAGE: 40.68V ~ MAX POWER VOLTAGE: 33.94V '`A~o�`' SHORT CIRCUIT CURRENT: 1U52A � STRUCTURAL ONLY LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2017: 690.13(B) '• i • • lit •• NOT RELOCATE OVERCURRENT DEVICE LABEL LOCATION: ADJACENT TO PV BREAKER (IF APPLICABLE). PER CODE(S): NEC 2017: 705.12(13)(2)(3)(b) LOCATION:LABEL INTERCONNECTION. PER •• i 69054 LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF APPLICABLE). PER CODE(S): NEC 2017: 705.12(B)(2)(3)(c) �r IIAL POWER ^�til=lJa'�! SOURCES:r • ' SOLAR SYSTE" LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S): NEC 2017: 705.12(B)(3) Wl,BEL LOCATION: INSTALLED WITHIN TOFD SHUT DOWN SWITCH PER •! i . l i •i i i• RAPIDTURN # # SWITCH TO T POSITION # �II TO SHUT III DOWN PV SYSTEM • REDUCE SHOCK -• IN THE LABEL • • CONNECTED.ARE PER •; •i 13 NOTES AND SPECIFICATIONS: • SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. • SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. • LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. • LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. • SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. • DO NOT COVER EXISTING MANUFACTURER LABELS. .�EN CEAls < No 64923 49 k �//9Oi 710/111110 \ STRUCTURAL ONLY