HomeMy WebLinkAbout21-3073;t N ® i l'
�Y:z`1 e•
5335 Eighth Streetyc3y�r,<,n,fi��n°
�`v\`z„{\ r
tiyyvy ;ql t �
v,
Zephyrhills, FL 33542
BNR-003073-2021
Phone: (813) 780-0020
Fax: (813) 780-0021
Issue Date: 12/1412021
7538 Broad Pointe Dr 35 25 21 0180 01200 0250 ti
,`•,<.: t� u:, . �\, t \\. <, vvi\�h\';, a `,aQ .,,�z„ , t. �4 s .,\1:\t�
Name: D R HQRTQN INC Permit Type: Building New (Residential)
Contractor: DR NORTON
Class of Work: SFR Construct
Address: 12602 Telecom Dr Building Valuation: $105,000.00
TAMPA, FL 33637 Electrical Valuation: $7,000.00
Phone: (813) 549-1968 Mechanical Valuation: $5,000.00
Plumbing Valuation: $7,500.00 r'
Total Valuation: $124,500.00
Total Fees: $18,389.50
Amount Paid: $18,389.50
Date Paid: 12/14/2021 1:25:43PM
CONSTRUCT SINGLE FAMILY 2362 SQ FT ZL
Driveway Fee $45.00 Electrical Plan Review Fee $37.50
Public Safety Impact Fee -Police $254.00 Building Permit Fee $565.00
School Impact Fee - Single Family $8,328.00 Park Impact Fee - Single Family/Townhome $769.56
Address Fee $30.00 Electrical Permit Fee
$75.00
Building Plan Review Fee $282,50 Plumbing Permit Fee $77.50
Mechanical Plan Review Fee $32.50 Water Connection Residential Fee $1,010.00
Mechanical Permit Fee $65.00 Transportation Impact Fee - City $36.32
Sewer Connection Residential Fee $2,090.00 Plumbing Plan Review Fee $38.75
Transportation Impact Fee $3,595.68 SIF 1 percent Fee $83.28
Irrigation 3/4 Meter (Cale) $473.78 3/4 Water Meter Fee (Cale) $473.78
Public Safety Impact Fee -Admin $26.35
REINSPECTIQN FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection, whichever is greater, for each subsequent reinspection.
Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing, consult with your lender or an attorney
before recording your notice of commencement."
accordanceComplete Plans, Specifications add fee Must Accompany Application. All work shall be performed in
Ordinances.•OCCUPANCY BEFORE t
i OCCUPANCY BEFORE C.O.
CONTRACTOR SIGNATURE PE IAIT OFFICEU
PERMIT
r EXPIRES
'u' • MONTHS APPROVED
:: r
INSPECTIONCALL FOR •
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
Date Received MMoyes@drhorton.com
Phone Contact for Permitting
Ii[tg>< a
Owner's Name DR Horton Inc Owner Phone Number 813-549-1 968
Owner's Address 1 12602 Telecom Drive; Tampa, FL 33637 Owner Phone Number
Fee Simple Titleholder Name Same Owner Phone Number
: i, . a i g .
i� t� � i 1 � ; '� �• , 1 ,,�tl i _ = _ - �.. is • mil "sV ' N�
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED NEW CONSTR e ADD/ALT SIGN 0 DEMOLISH
El INSTALL REPAIR
PROPOSED USE SFR COMM OTHER
TYPE OF CONSTRUCTION BLOCK FRAME STEEL
DESCRIPTION OF WORK New Single Family Residence LA Beds, Baths, Story Hom
BUILDING SIZE SQ FOOTAGE HEIGHT
=BUILDING $ VALUATION OF TOTAL CONSTRUCTION
®ELECTRICAL $ _ AMP SERVICE PROGRESS ENERGY W.R.E.C.
=PLUMBING $
®MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION ,
GAS ROOF
ING SPECIALTY OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO
BUILDER COMPANY DR Horton, Inc
SIGNATURE REGISTERED Y / N FEE CURREN Y / N
Address 12602 Telecom Drive; Tampa, FL 33637 License # I CBC039062-,
ELECTRICIAN4"V COMPANY Strada Electric
SIGNATURE REGISTERED Y / N FEE CURREN
Address 3400 St Johns Pkwy; Sanford, FL 32771 License # EC13003715
PLUMBER COMPANY Northwest Plumbing
SIGNATURE REGISTERED Y / N J FEE CURREN Y / N
Address 6310 Mabelfion PVNy, St 1000; Mableton, GA 30126 License # I CFC1427137
MECHANICAL COMPANY Progressive Air Systems
SIGNATURE el REGISTERED Y / N FEE,CURREN Y / N
Address 7130 Meighan Ct; New Part Richey, FL 34652 License # I CAC033669
OTHER COMPANY Brad McDonald Roofing
SIGNATURE 4,0 REGISTERED Y / N FEE CURREN Y / N
Address 7143 SR 54; New -Port Richey, FL 34653 License # I CC1325833
RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction,
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects
COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction.
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance
SIGN PERMIT Attach (2) sets of Engineered Plans.
****PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner & Contractor sign back of application, notarized
If over $2500, a Notice of Commencement is required. (A/C upgrades over $7500)
** Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage)
Driveways -Not over Counter if on public roadways..needs ROW
813-780-0020 {}hx nfZephyrhiUo Permit Application Fo»-813-780-0021
Building Department
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deru^restrictions" which may be more restrictive
than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they
may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and
contractor may be cited for a misdemeanor violation under state law, If the owner or intended contractor are uncertain as to what licensing requirements
may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009.
Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s� sign portions of the "contractor Block" ofthis
application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is
not entitled to permitting privileges in Pasco County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or
expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that
such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery
Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final
power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior
to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant,
have been provided with a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of
Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described
document and promise in good faith to deliver it to the "owner" prior to commencement,
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with
all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as
indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all
laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction, I also certify that I
understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I
must take to be in compliance. Such agencies include but are not limited to:
- Department of Environmental Protection -Cypress Bayheads, Wetiand Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
- Southwest Florida Water Management District -Wells, Cypress Bayheads, Wbtland Areas, Altering
Watercourses.
- Army Corps of Engineers -Seawalls, Docks, Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-VVeUo, Wastewater Tnwebnent.
Septic Tanks. ^
- U3 Environmental Protection Agency -Asbestos abatement.
- Federal Aviation Authority -Runways. .
| understand that the following restrictions apply tnthe use offill:
- Use of fill is not allowed in Flood Zone Wr unless expressly permitted.
- If the fill material is to be used in Flood Zone ^A., it is understood that a drainage plan addressing e
^oomponuating volume" will be submitted at time of permitting which is prepared by e professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone connection with a permitted building i stem U
construction, I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to
commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or
other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as
authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from
thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work
authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a
period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to
exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered
CO
OWNER OR AGENT
Su a�swm�(f(or Affirmea) biafm his~— sm
_
Who is/are personally known tommorhas/have produced wm
—as identification.
Notary Public
Commission No.— q
M��R�N�
�
Commission #GOQ454U9
Expires May 3, 2024
,»*"�~
9oW*dmm6**m0IWyoW*"
rOR
and sworn to (or affirmed) before me this
isfare personally known to me or has/have produced
as identification.
Commission No
P s
A CO COUNTY, FLORIDA
Per No.
der NametOwner Name Date Permltiad-��—��—
Control
County Parcel No,
bDIv:
Address/Location 7,53b 61-o
50
Classificationfrype of Use YA
TRANSPORTATION IMPACT FEE , Rate:
Sq. Ft Unit2—
Exempt Ves E] NO How Determined
Impact Fee Amount Zone No.
— TAZ:
Account (056) Single -Family Detached House
Amount $
(067) Mobile Home
(058) Other Residential
123) Collects Fee
Exempt Yes No How Determined
1E E-
1
Lani'd Account Land Credit —
Land Total
Recreation Account Recreation Credit
Recreation Total
Zone TOTAL AMOUNT
Exempt El Yes Ej No HOW Determined
Land Account Lend Credit
Land Tote I
Facility Account Facility Credit
Facility Total
Exempt [j Yet; E] No How Determfined
Total punt
ERUI
TOTAL AMOUNT
IT -----------
Checked By
NO CERTIFICATE OF OCC I ILL
A0101OWled0smant below does not Imply SCOOPWOO Of Concurrence, but simply receipt of copy of th
the building permit Owner. on rjoilce of this assessment an Is toffnlacing
the conditions Of Payment for same. .P
RECEIPT NO. ---. DATE BY
2
shall be a rninirrirrin of(S" above the road elevation and an engineered site plan,
Lots shall be graded to comply with R401 .3 of the F,B,(',
3Compaction test required if``" "a or Tnore of fill dirt is brought in at any one place,
4, Tie in survey required bdrore pouring concrele,
5, Drivexvays require a R,O.W, use pernilt, All 4 sides of driveway thru the sidewalk shall have
expansion material,
6, All setbacks shall be niet,
7, All property nia.rkers shall be uncovered and niarked at tirrie of first inspectiOri,
8, All AD.A. reqUirements shall be nwt,
9, No electric, plumbing, raeclianical, or fra.ming shall be covered WithOLIt an inspection and
approval first,
M All Garages shall comply with section R302,6 ofthe F.B,C. (Fire Separation).
11, Appliances shall not be installed in a location where sutaject to mechanical darnage unless
protected by approved barriers, M303A of the F,B,C
12, Water heaters shall cornply with section P60713 of the F.B.C,
13, Foundation supports for A/C units shall be raised at least 3"' above finished grade. M 1 308A
14, Return air in all bedrooms, F.B,C, M 16/20A
15, Smoke detectors are to be installed in accordance with R3 13,1 of the F.B,C,
16, All gJazing requirements are to be in accordance with R308.4 of tire F,,B,C,
17, All inearis of egress are to be in accordance with 311 of the FRC,
18, "Green gy suin board" shall nused riot be aa s backer in showers or tubs, RFC 702,4.2 R,
1P
19, Conibination-type AFCl breakers are required at all locatioris re(jUiring an ARA type breaker,
20, Carbon monoxide alarms will be required in new construction that uses fossil-bUrning heating
car appliances or ati attached garage, They shall Inc, installed in accordance with the FRC�
21, All PlUtribing., mechanical, and electrical shall be separate fro,111 LIT'lit to Ullit, This includes all
underground plumbing and electric.
22, All 2016 1,E,C. Codes will be enforced,
23, Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N, E,C
2.4, In accordance with the Land Development Code, lots shall be sodded before Final atleast 10
feet around the stnicture.
25. R403,5.31-tot water pipe insulation
Insulation for hot water pipe with a minirrium thermal resistance (R-value)eat R-3 shall be applied to the
following:
Piping 1, inch (19,1 mm) and larger in norninal diameter,
Piping serving more than one dwelling unit,
Piping located outside "he conditioned space,
Piping from the water heater to a distribution manifold,
Piping located under a floor slab,
Buried in piping,
Supply and return piping in recirculation systems other than demand redrUflation systems.
25, Blower door test shall be provided before C.O.
2 6. 11 dintes.
2Z erntit be ore WaL
2&
F.F.E.-Finished Floor Elevation
F.B.C- Florida Building Code 6"' Edition
R.O.W.-Right of Way
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
)ate Received '
Phone Contact for Permitting Moyes@hodrhorton-com
CIO JK a a a X I a It a WW g a@drhorton.com
tit a
Owner's Name DR Horton Inc owner Phone Number 813-549-1968
Owner's Address 12602 Telecom Drive; Tampa, FL 33637 Owner Phone Number F
--ee Simple Titleholder Name Lame Owner Phone Number F
=ee Simple Titleholder Address
JOB ADDRESS I LOT #
3UBDIVISION Abbott Park (Zephyr Lakes) PARCEL ID#E—
(OBTAINED FROM PROPERTY TAX NOTICE)
NORK PROPOSED NEW CONSTRF71 ADD/ALT SIGN DEMOLISH
INSTALL REPAIR
PROPOSED USE SFR COMM OTHER
TYPE OF CONSTRUCTION BLOCK FRAME STEEL
DESCRIPTION OF WORK
BUILDING SIZE I SQ FOOTAGE= HEIGHT
NIA BUILDING rT 1*'N/A ----------------- I VALUATION OF TOTAL CONSTRUCTION I
EE]ELECTRICAL I' N/A AMP SERVICE PROGRESS ENERGY W.R,E.C.
N/A PLUMBING $ _N/A
N/A MECHANICAL $ N/A VALUATION OF MECHANICAL INSTALLATION
[E] GAS ROOFING SPECIALTY = OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO
BUILDER COMPANY E
SIGNATURE REGISTERED YIN FEE CURREN
Address License #E::::==
ELECTRICIAN COMPANY E
SIGNATURE REGISTERED ;;;FEE CURREN
Address I License # =====
PLUMBER COMPANY Lawn Medic Landscape & Irrigation
SIGNATURE REGISTERED Y/N FEE CURREN L_YLN _J
Address 4827 Beauchamp Rd; Plant City, FL 33563 Lice,set SCC131152084
MECHANICAL COMPANY F
SIGNATURE REGISTERED YIN FEE CURREN Y/N
Address License #E====
OTHER COMPANY
SIGNATURE REGISTERED Y/N FEE CURREN Y/N
Address License
9999118111 1 a a I I a I a I as 22-111111 a a I a I as I a a 9:1112149229 a a #94 11 a -It a I I I's III's I al
RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction,
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans wl Silt Fence installed,
Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects
COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms, R-O-W Permit for new construction.
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance
SIGN PERMIT Attach (2) sets of Engineered Plans.
****PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner & Contractor sign back of application, notarized
If over $2500, a Notice of Commencement is required. (AIC upgrades over $7500)
— Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences (Plot/SurveylFootage)
Driveways -Not over Counter if on public roadways..needs ROW
813-780-0020 City of ZephyrhU\sPermit Application m�13-780-0021
Building Department
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restdctive
than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they
may be required to be licensed in accordance With state and local regulations, If the contractor is not licensed as required by law, both the owner and
contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements
may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009.
Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" ofthis
application for which they Mi I be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is
not entitled to permitting privileges in Pasco County.
TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The Undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or
expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that
such fees, as may be due, Will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery
Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final
power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior
to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant,
have been provided With a copy of the "Florida Construction Lien Law—Homeowner`s Protection Guide" prepared by the Florida Department of
Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described
document and promise in good faith to deliver it to the "owner" prior to commencement.
CONTRACTOR'SIOWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with
all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as
indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all
laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I
understand that the regulations of other govemment agencies may apply to the intended work, and that it is my responsibility to identify what actions I
must take to be in compliance, Such agencies include but are not limited to:
Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment,
� Southwest Florida Water Management Disthot40eUs, Cypress Bayhaodo' VVet|and Areaa, Altering
Watercourses.
' Army Corps of Engineers -Seawalls, Docks, Navigable Waterways.
- Deportment of Health & Rehabilitative Servicew/Environmental Health Unit4WaUn, Wastewater Treatment,
Septic Tanks.
' USEnvironmental Protection Agency -Asbestos abatement.
' Federal Aviation Authority-Runwmys.
| understand that the following restrictions apply tnthe use uffill:
- Use offill ionot allowed inFlood Zone ''\y'unless expressly permitted.
' If the fill material is to be used in Flood Zone "A^, it is understood that a drainage plan addressing a
compensating volume" will be submitted at time of permitting which is prepared by e professional engineer
licensed bythe State ofFlorida.
- If the fill material is to be used in Flood Zone "A^ in connection with a permitted building using stem wo||
construction, | certify that fill will be used only tofill the area within the stem wall.
- If fill material is to be used in any area, | certify that use of such fill will not adversely effout adjacent
properties. If use of fill is found to adversely affect adjacent propertiea, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots |aas than one (1)
acre which are elevated by fill, engineered drainage plan iorequired.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to
commencing construction. / understand that aepmnma permit may be required for o/eunco/ work, plumbing, signs, veuu pools, air conditioning, gas, or
other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as
authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from
thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work
authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a
period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to
exceed ninety (90) days and Will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered
OWNER OR AGE CONTRACTOR
2 Su crib d and sw rr;n—t ( a*ffl-n'"n"ed) rbe_fo'rt`m__WEMhis_ Subscribed and sworn to (or affirmed) before me this
Who islare personally known to me or has/have produced Who isfare personally known to me or has/have produced
as identification. as identification.
Notary Public
Mots
Name of Notary typed, printed or stamped
HEATHER MUNDT
ComnhWm,#GG $45409
ExphnMay 3, 2024
°orp�'
m��mmm��wm�wwwmw
Commission
Name of Notary typed, printed or stamped
0111LIJEUM&S "IN
Notary Public
PLOT PLAN
DESCRIPTICIN:(AS FURNISHED)
LOT 25, BLOCK 12, ZEPHYR LAKES SUBDIVISION PHASE 4B
AS RECORDED IN PLAT BOOK 85, PAGE(S) 126-128, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA.
r
1" = 30'
GRAPHIC
0 15 30
ON LOT CALCULATIONS
LOT
= 6,250
SQ. FT.
LIVING AREA
= 1,828
SQ. FT.
GARAGE
= 430
SQ. FT.
ENTRY
= 16
SQ. FT.
LANAI
= 88
SO. FT.
PATIO
= 0
SQ. FT.
DRIVEWAY
= 440
SQ. FT.
A/C PAD
= 12
SQ. FT.
WALKWAY
= 28
SQ. FT.
IMPERVIOUS
= 45%
= 2842
SQ. FT.
SOD
= 3,408
SQ. FT.
OFF LOT CALCULATIONS
RIGHT OF WAY
= 650
SQ. FT.
DRIVE APRON
= 152
SQ. FT.
PUBLIC S/W
= 250
SQ. FT.
SOD
= 248
SQ, FT.
TOTALS
AREA
= 6,900
SQ. FT,
DRIVEWAY
= 592
SQ. FT.
SIDEWALK
= 278
SQ. FT,
SOD
= 3,656
SQ. FT
ouj
_jz 1 0
BROAD POINTE DRIVE
TRACT "A"
50' WIDE PRIVATE RIGHT OF WAY
U) 62 (REFERENCE BEARING) PCP
S89'53'26"E 314.94�
PI CENTERLINE OF
193.36,
RIGHT OF WAY
b
Ioui
ui
z
5 �T
T
LOT 24
BLOCK 12
AR F 0()!,
E
111pi iln III
ills
FRONT:
22'
GARAGE:
27'
REAR:
13,
SIDE:
5'
SIDE STREET:
15'
NOTES:
1. PROPOSED ELEVATIONS SHOWN HEREON ARE
BASED ON THE APPROVED ENGINEERING PLANS
PREPARED BY HAMILTON ENGINEERING &
SURVEYING INC.
2. ELEVATIONS ARE BASED ON NAVID 1988
DATUM.
THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES
ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF
THE PROPOSED STRUCTURE. THE CONTRACTOR AND/OR
OWNER ARE REQUIRED TO VERIFY ALL SETBACKS, BUILDING
DIMENSIONS, AND LAYOUT SHOWN HEREON PRIOR TO ANY
CONSTRUCTION.
THIS IS NOT A SURVEY
THIS IS A PLOT PLAN ONLY
FLOOD NOTE: I HAVE EXAMINED THE F.I.R.M. MAP NO, 12101CO293F
DATED 09/26/2014, AND FOUND THE SUBJECT PROPERTY APPEARS TO
UE PARTIALLY IN ZONE —X— & 'A", ZONE *X", AREAS DETERMINED TO BE
OUTSIDE THE 0.2% ANNUAL CHANCE FLOOOPLAIN. ZONE "A", AREAS
DETERMINED TO BE SPECIAL FLOOD HAZARD AREAS SUBJECT TO
INUNDATION BY THE 1% ANNUAL CHANCE FLOOD EVENIETHE SURVEYOR
MAKES NO GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE
CONTACT THE LOCAL F.E.M.A. AGENT FOR VERIFICATION.
IBEARING BASIS:
BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF BROAD
POINTS DRIVE BEING S89-53'26-E, PER PLAT. I
(FIELD DATE:) -
SCALE: 1* = 30 FEET
APPROVED BY: JB
JOB NO.210733 LOT 25, BLOCK 12
— —
DRAWN BY, --RS—B
10' UE
o---------
L0 'DRIVE,
5.2'ENTRY
PROPOSED
CAU
m 6
4EBB — "C"
FINISHED FLOOR
ELEVATION=95J0'
39,67'
COVERED
LANAI ,
n6
LOT 25
BLOCK 12
6,250 SO. FT
DRAINAGE TYPE A
I_.—.—.—.
WE
ZEPHYRHILLS COLONY COMPANY
PLAT BOOK 1, PAGE 55
LEGEND:
BUILDING SETBACK LINE
CENTERLINE
RIGHT OF WAY LINE
PROPOSED ELEVATION
PROPOSED DRAINAGE FLOW
CONCRETE
A/C
AIR CONDITIONER
S/W
SIDEWALK
LOT 26
BLOCK 12
PI PONT OF INTERSECTION
PC POINT OF CURVATURE
PT POINT OF TANGENCY
RP RADIUS POINT
PRC POINT OF REVERSE CURVATURE
PCP PERMANENT CONTROL POINT
TYP TYPICAL
cs CONCRETE SLAB
(P) PER PLAT
(C) CALCULATED
PB PLAT BOOK
PGS PAGES
SO* FT.SQUARE FEET
F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY
F.I.R.M. FLOOD INSURANCE RATE MAP
NAVD NORTH AMERICAN VERTICAL DATUM
D&UE DRAINAGE & UTILITY EASEMENT
DE DRAINAGE EASEMENT
UE UTILITY EASEMENT (PUBLIC)
SURVEYOR NOTES:
1, THE SURVEYOR HAS NOT ABSTRACTED THE
LAND SHOWN HEREON FOR EASEMENTS, RIGHT
OF WAY, RESTRICTIONS OF RECORD WHICH
MAY AFFECT THE TITLE OR USE OF THE LAND.
2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN
LOCATED EXCEPT AS SHOWN.
3. T VALID WITHOUT THE AUTHENTIC
ELECTRONIC SIGNATURE AND THE AUTHENTIC
ELECTRONIC SEAL OF A FLORIDA LICENSED
SURVEYOR AND MAPPER.
Dl9itally,ig-dbyJames B.1,—n
DN—US,,t=F].,1d,,,I-Orlando
,
Americ- Survey 9 & Mapping,
—P'.fessjona� Land lur-I.,,
—0=jb.l--@._.,p.,a,..c.m FOR
Date 2021.0921 08 31 20 -04'00� THE
Adobe Acrobat-,,i-: 11,0.23 FIRM
PSM# 6485 DATE