Loading...
HomeMy WebLinkAbout21-3077r � + r R R 0 0 Ilk t II, 11 Date:Issue Permit Building NewfResidential 7567 Broad Pointe Dr 35 25 21 0180 011000 0220 ffill It 0i �����i��?' Name: D R HORTON INC Permit Type: Building New (Residential) Contractor: DR HORTON Class of Work: SFR Construct Address: 12602 Telecom Dr Building Valuation: $105,000.00 ,� a TAMPA, FL 33637 Electrical Valuation: $7,000.00 Phone: (813) 549-1968 Mechanical Valuation: $5,000.00 x Plumbing Valuation: $7,500.00° Total Valuation: $124,500.00 Total Fees: $18,389.50 Amount Paid: $18,389.50 f Date Paid: 12/9/2021 2:06:43PM -41 � �' -',x.^'. ,_. w, t.,}l.„> CONSTRUCT SINGLE FAMILY 2362 SQ ZL 4t•:��-'�.. `l ,.? � t�-,, ♦ 1". ". ;a.}c.. ?i ',aFti 'i�,>?".,. � ts,�o t ,a. ,. .",ti tx -a5. 1..."1�, ;i .t �., z t .S Park Impact Fee - Single Family/Townhome $769.56 Address Fee $30.00 Transportation Impact Fee - City $36.32 Mechanical Plan Review Fee $32.50 School Impact Fee - Single Family $8,328.00 Public Safety Impact Fee -Admin $26,35 Water Connection Residential Fee $1,010.00 Building Permit Fee $565.00 Mechanical Permit Fee $65.00 Plumbing Permit Fee $77.50 Driveway Fee $45.00 Electrical Plan Review Fee $37.50 Transportation Impact Fee $3,595.68 Electrical Permit Fee $75.00 SIF 1 percent Fee $83.28 Irrigation 3/4 Meter (Cale) $473.78 Plumbing Plan Review Fee $38.75 314 Water Meter Fee (Cale) $473,78 Sewer Connection Residential Fee $2,090.00 Building Plan Review Fee $282.50 Public Safety Impact Fee -Police $254.00 REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.Q. NO OCCUPANCY BEFORE C.O. CO&TRACTOR SIGNATURE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT RL CARD , FROM i WEATHER R �ASCO COUNTY, FLORIDA Pennit No. Date PermittedA -liuCider NametOwner Name Control # � County Parcel No. AddroWLocation Classification/Type TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: Exempt [] Vas No How Determined impact Fee Amount . 3, 0-!3?-- Zone No. - TAZ: Account (056) Single -Family Detached House Amount $ (067) Mobile Home (058) Other Residential 123) Collection Fee Exempt yes No How Determined It "will II Land Account Land Credit - Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT Exempt E] Yes E] No How Determined Land Accounf Land Credit Land Tnt�l Facility Account Facility Credit Facility Total Exempt Yes []No How Determined Total Amounr RESOURCE FEE -- TOTAL AMOUNT Prepared By Chocked By NO CERTIFICATE OF OCCUPAMICY-344LL 9V III WOF PAISCO CO 114'EM4 '- 6 * "W.-MMOMMI, RECEIPT NO. DATE By 813-780-0020 City Of Zephyrhills Permit Application Fax-813-780-0021 Building Department i Date Received' MMoyes@drhorton.com Phone Contact for Permitting it 1621taxassaxass I �7 Owner's Name DR Horton Inc Owner Phone Number 13-549-1968 Owner's Address 1 12602 Telecom Drive; Tampa, FL 33637 Owner Phone Number' Fee Simple Titleholder Name Setme Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS LOT # SUBDIVISION I Abbott Park PARCEL ID# 1 040 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD/ALT SIGN 0 DEMOLISH H INSTALL REPAIR e PROPOSED USE SFR COMM OTHER TYPE OF CONSTRUCTION 0 BLOCK FRAME STEEL DESCRIPTION OF WORK New Single Family Residence Beds, Baths, Story HOm ` BUILDING SIZE �^ SQ FOOTAGE HEIGHT =BUILDING Las—W-01 VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ AMP SERVICE PROGRESS ENERGY W.R.E.C. =PLUMBING $ pig MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION mot°` 77 =GAS ROOFING SPECIALTY OTHER ro FINISHED FLOOR ELEVATIONS 4t+ �, FLOOD ZONE AREA =YES NO BUILDER COMPANY DR Horton, Inc SIGNATURE REGISTERED L_ILN___j FEE CURREN Y I N Address 12602 Telecom Drive; Tampa, FL 33637 License # I CBC039062 ELECTRICIAN COMPANY Strada Electric SIGNATURE REGISTERED Lyj N FEE CURREN Y/ N Address 3400 St Johns Pkwy; Sanford, FL 32771 License # EC13003715������ PLUMBER COMPANY Northwest Plumbing SIGNATURE REGISTERED Y / N FEE CURREN Y / N Address 6310 Mabelton PVwy, St 1000; Mableton, GA 30126 License # CFC1427137 MECHANICAL `_ COMPANY Progressive Air Systems SIGNATURE r REGISTERED Y / N FEE CURREN Y/ N air Address 7130 Meighan Ct; New Port Richey, FL 34652 License # CAC033669 OTHER COMPANY Brad McDonald Roofing SIGNATURE M1 REGISTERED Y / N FEE CURREN ' / N Address 7143 SR 54; New art Richey, FL 34653 License # CC1 825833 1111s1t1€1ti11 11tifITilsit It141E1I€4fil isItIlistI RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (A/C upgrades over $7500) ** Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage) Driveways -Not over Counter if on public roadways..needs ROW 813-780*020 City ofZephvrhiUs Permit Application Fo^-813-780-0021' Building Department NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to ne°d^restrictions" which may be more momctwv than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations, If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law, If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009, Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" ofthis application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees,, as,may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees, and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant, have been provided With a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner' prior to commencement. CONTRACTOR'SIOWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District -Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. ` - Army Corps of Engineers -Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-VVe|o, Wastewater Treatment, Septic Tanks. ' USEnvironmental Protection Agency -Asbestos abatement. - Federal Aviation Authority -Runways. | understand that the following restrictions apply tothe use u/fill: - Use offill ionot allowed inFlood Zone ''V^unless expressly permitted. - If the fill material is to be used in Flood Zone ''A'. it is understood that o drainage plan addressing a ''compeneeding volume" will be submitted at time of permitting which is prepared by m professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone ''A" in connection with a perndtted building using stem wo|| construction, | certify that fill will be used only tofill the area within the stem wall. - If fill material is to be used in any area, | certify that use of such fill will not adversely effect adjacent properties. If use of fill is found to adversely affect adjacent proportiee, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated byfill, anengineered drainage plan isrequired. |f|omthe AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. | understand that aseparate permit may unrequired for electrical work, plumbing, signs, wells, pools, air conditioning, gas, n, other installations not specifically included mthe application. Apermit issued shall hoconstrued muoulicense mproceed with the work and not aa authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit preventthe Building Official from thereafter requiring vcorrection oferrors inplans, construction nrviolations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (yV)days and will demonstrate justifiable cause for the extension, If work ceases for ninety (90) consecutive days, the job is considered abandoned. =WSu scri ad and sw ��It_ I- hi s Subscribed and sworn to (or affirmed) before me this b Michelle Moyes by Who is/are personally known to me or has/have produced Who islare personally known to me or has/have produced as identification. —as identification, eEiNotary Public Commission No. — Name of Notary typed, printed or stamped HEATHER MUNDT � Commission Expires May 3, 2024 �*�� 6oW*dmm6ud0NeWy$0Mm Commission PLOT PLAN DESCRIPTICIN:(AS FURNISHED) LOT 22, BLOCK 11, ZEPHYR LAKES SUBDIVISION PHASE 4B AS RECORDED IN PLAT BOOK 85, PAGE(S) 126-128, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. , 0 n 30, GRAPHIC SCALE F-1 5 30 ON LOT CALCULATIONS LOT = 5,750 SO. FT. LIVING AREA = 1,828 50. FT, GARAGE = 430 SQ. FT. ENTRY = 16 SO. FT. LANAI = 88 SQ. FT. PATIO = 0 SQ. FT. DRIVEWAY = 440 SQ. FT. A/C PAD = 12 SO. FT. WALKWAY = 28 SQ. FT. IMPERVIOUS = 49% = 2842 SQ. FT. SOD = 2,908 SO. FT. OFF LOT CALCULATIONS RIGHT OF WAY = 650 SQ. FT. DRIVE APRON = 152 SQ. FT. PUBLIC S/W = 250 SQ. FT. SOD = 248 SQ. FT. TOTALS AREA = 6,400 SO, FT. DRIVEWAY = 592 SQ, FT. SIDEWALK = 278 SQ. FT. SOD = 3,156 SQ. FT. BUILDING SETBACKS FRONT: 22' GARAGE: 27' REAR: 13' SIDE: 5' SIDE STREET: 13' NOTES: 1. PROPOSED ELEVATIONS SHOWN HEREON ARE BASED ON THE APPROVED ENGINEERING PLANS PREPARED BY HAMILTON ENGINEERING & SURVEYING INC. 2. ELEVATIONS ARE BASED ON NAVID 1988 DATUM. THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES ONLY, THIS IS NOT INTENDED FOR THE CONSTRUCTION OF THE PROPOSED STRUCTURE. THE CONTRACTOR AND/OR OWNER ARE REQUIRED TO VERIFY ALL SETBACKS, BUILDING DIMENSIONS, AND LAYOUT SHOWN HEREON PRIOR TO ANY CONSTRUCTION. THIS IS NOT A SURVEY THIS IS A PLOT PLAN ONLY FLOOD NOTE: I HAVE EXAMINED THE F.I.R.M. MAP NO. 12101CO293F DATED 09/26/2014, AND FOUND THE SUBJECT PROPERTY APPEARS TO LIE PARTIALLY IN ZONE -X" & 'A'. ZONE "X", AREAS DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE FLOODPLAIN. SUBJECT AREAS DETERMINED TO BE SPECIAL FLOOD HAZARD AREAS SUBJECT TO INUNDATION BY THE 1X ANNUAL CHANCE FLOOD EVENIETHE SURVEYOR MAKES NO GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE CONTACT THE LOCAL F.E.M.A. AGENT FOR VERIFICATION. BEARING BASIS: BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF BROAD POINTE DRIVE BEING N89-53'26-W, PER PLAT. (FIELD DATE:) SCALE: I' = 30 FEET APPROVED BY: ---J1-3 JOB NO. 210733 LOT 2-2, BLOCK 11 DRAWN BY. DSB LOT 12 LOT 11 LOT 10 BLOCK 11 BLOCK 11 1-8 BLOCK 11 M S89*53'26 E 50.00 a. 0 LOT 22 0 _90 BLOCK 11 L0 5,750 SQ. FT t II DRAINAGE TYPE A 7 5.2' 77� 1 5.2' 28.7, c6 QOyERE 1A 11.0, 39.67' LOT 21 PROPOSED LOT 23 CAU BLOCK 11 4EBB — "D" BLOCK 11 Ld FINISHED FLOOR ZEPHYR LAKES SUBDIVISION EUEVAIION-91.40 PHASE 4D 82 PLAT BOOK' 84, PAGE 0 0 0 COVERED ENTRY 0 z 5,2' fft 14XI 5.2, ,-DRIVE u) 4 10' UE p CENTERLINE OF 264.9 50.00' PCP I RIGHT OF WAY N89'53*26",W 314.94' (REFERENCE, BEARING) BROAD POINTE DRIVE z io TRACT "A" D co 50' WIDE PRIVATE RIGHT OF WAY BUILDING SETBACK LINE CENTERLINE RIGHT OF WAY LINE PROPOSED ELEVATION PROPOSED DRAINAGE FLOW CONCRETE A/C AIR CONDITIONER S/W SIDEWALK �qQg, -Mm 41 1 it ti ol MAPPINGs INC. PI PONT OF INTERSECTION PC POINT OF CURVATURE PT POINT OF TANGENCY RP RADIUS POINT PRO POINT OF REVERSE CURVATURE PCP PERMANENT CONTROL POINT TYP TYPICAL cs CONCRETE SLAB (P) PER PLAT PC) CALCULATED B PLAT BOOK PGS PAGES So. FT. SQUARE FEET F,E,M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY F.I.R,M. FLOOD INSURANCE RATE MAP NAVD NORTH AMERICAN VERTICAL DATUM D&UE DRAINAGE & UTILITY EASEMENT DE DRAINAGE EASEMENT UE U11UTY EASEMENT (PUBLIC) SURVEYOR NOTES: 1, THE SURVEYOR HAS NOT ABSTRACTED THE LAND SHOWN HEREON FOR EASEMENTS, RIGHT OF WAY, RESTRICTIONS OF RECORD WHICH MAY AFFECT THE TITLE OR USE OF THE LAND, 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCATED EXCEPT AS SHOWN. 3, NOT VALID WITHOUT THE AUTHENTIC ELECTRONIC SIGNATURE AND THE AUTHENTIC ELECTRONIC SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. oiqjtally sig,ed by Jam" Bodc'man ,0 % DN! —American Surveying & Mappng, Land S.,-pr, emalljboleman@asmcorporate.com FOR Date 2021.09.21 08:30:50 -0400THE Adobe A—lb,,tv—i— 1 1,U3 FIRM JAMES W. BOLEMAN PSM# 6485 DATE 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department )ate Received Phone Contact for Permitting MMoyes@drhorton.com aat aaaaa IL-KAA_R_"� � I I a I a a RX. its all == I owner's Name DR Horton Inc "I Owner Phone Number 813-549-1968 owner's Address112602 Telecom Drive; Tampa, FL 33637_] Owner Phone Number =ee Simple Titleholder Name ISarne Owner Phone Number =ee Simple Titleholder Address JOB ADDRESS I LOT # SUBDIVISION Abbott Park (Zephyr Lakes) PARCEL (OBTAINED FROM PROPERTY TAX NOTICE) NORK PROPOSED NEW CONSTR ADD/ALT SIGN 0 DEMOLISH INSTALL 8 REPAIR PROPOSED USE SFR COMM OTHER TYPE OF CONSTRUCTION BLOCK FRAME STEEL DESCRIPTION OF WORK BUILDING SIZE I SQ FOOTAGE HEIGHT [NE]BUILDING 1$ N/A VALUATION OF TOTAL CONSTRUCTION [EE]ELECTRICAL 1'N/A AMP SERVICE PROGRESS ENERGY W.R.E.C. EN/A PLUMBING 1 $ N/A NIA MECHANICAL 1 $ N/A VALUATION OF MECHANICAL INSTALLATION NIA GAS ROOFING SPECIALTY = OTHER = FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA YES NO BUILDER COMPANY [ — SIGNATURE REGISTERED L_y N FEE CURREN YIN Address License #E:==== ELECTRICIAN COMPANY E SIGNATURE REGISTERED ;;/ N FEE CURREN Address License #E:==== PLUMBER COMPANY Fawn Meclic Landscape & Irrigation SIGNATURE REGISTERED YIN FEE CURREN Y I N Address 4827 Beauchamp Rd; Plant City, FL 33563 License # MECHANICAL COMPANY SIGNATURE REGISTERED J FEE CURREN YIN Address License #E==== OTHER COMPANY SIGNATURE REGISTERED YIN FEE CURREN YIN Address License # at#* 1111its I 12922111111111 it.1221'#112 xss 11311 RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans wl Silt Fence installed, Sanitary Facilities & I dumpster; Site Work Permit for subdivisions/large projects COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Fill out application completely, Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (A/C upgrades over $7500) — Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage) Driveways -Not over Counter if on public roadways..needs ROW °- 813-780-0020 City OfZephvrhiUSPermit Application Fmx-813-780*021 Building Department NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance With state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" ofthis application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, Will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance, Furthermore, if Pasco County WaterlSewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances, CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant, have been provided Wth a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner' prior to commencement. CONTRACTOR'SIOWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated, I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also cerfify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, VVateoAVoatevvoharTreatment. � Southwest Florida Water Management Diethot4WeUa, Cypress Boyheodo' VVot|end Areas, Altering Watercourses. - Army Corps of Engineers -Seawalls, Ducks. Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment, Septic Tanks. - UGEnvironmental Protection Agency -Asbestos abatement. - Federal Aviation Authority-Runwaye. |undostand that the following restrictions apply mthe use offill: - Use offill ienot allowed inFlood Zone W^unless expressly permitted. - If the fill material is to be used in Flood Zone ''A", it is understood that o drainage plan addressing a ^oompensating volume" will be submitted at time of permitting which is prepared by professional engineer licensed bythe State ofFlorida. - If the fill material is to be used in Flood Zone "A" in connection with e permitted building using stem wo|| construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, | certify that use of such fill will not adversely effoot adjacent properties, If use of fill is found to adversely affect adjacent pnopertiea, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots |eaa than one (1) acre which are elevated by fill, on engineered drainage plan is required, |f|omthe AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. | understand that e separate permit may be requiredfor electrical workplumbing, signs,om||a pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT tsu or! dands�w'rlr�nt (ot affirmed) before md"this Subscribed and sworn to (or affirmed) before me this Who islare personally known to me or has1have produced Who is/are personally known to me or has/ ave produced as identification. as identification. /11 ft�4�TZota�wy Public Notary Public Com mission No— a Cr Commission No. Name of Notary typed, printed or stamped pua HEATHER MUNDT Commission #GG 045409 EXpIMoMay 3,2024 !�`ame of Notary typed, printed or stamped P tip:. ea, COUNTY, FLORIDA Permit No. _a0_2k__ Date Permitted //-)- Builder Name/Owner Name Control # County Parcel No, l Zc Sub iv: Address/Location 7&70 TRANSPORTATION IMPACT FEE lRate: Sq Ft Unit: -31S,3 Exempt C] Ves []No How Determined Impact Fee Amount 3632 Zone No. -L 041, � TAZ: Account (056) Single -Family Detached House Amount $ (057) Mobile Home (058) Other Residential 1123) Collection Fee Exempt Yes []No How Determined P KS =nt D RECMEATMON n d A� L and Credit Land Total Recreation Account Recreation Credit Recreation Total Zan TOTAL AMOUNT $ Exempt Yes No How Determined Land Account' Land Credit Land Total Facility Account Facility Credit Facility Total Exempt Yes No How Determined Total ERU TOTAL AMOUNT Prepared By Chocked By ----------------- -ACknowledgement below does not Imply acceptance Of concurrence, but simply receipt Of -a W0 Of this form, placing the bullding permit owner on notice Of thle assessment and the co ndillons, of payment for same. RECEIPT NO. DATE I BY 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received I I MMoyes@drhorton.com I I Phone Contact for Permitting I I 1i It a g a as § AREA 1 Owner's Name tDR Horton Inc Owner Phone Number813-549 -1968 Owner's Address 1 12602 Telecom Drive; Tampa, FL 33637 Owner Phone Number Fee Simple Titleholder Name ISame Owner Phone Number Fee Simple Titleholder Address sno 1131M (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR 8 ADD/ALT SIGN 0 DEMOLISH INSTALL REPAIR PROPOSED USE SFR COMM OTHER TYPE OF CONSTRUCTION BLOCK FRAME STEEL DESCRIPTION OF WORK I -New Single Family Residence Beds, Baths, Story Hom BUILDING SIZE SQ FOOTAGE HEIGHT I tkkWLkkkk k *_ q. k M k =BUILDING L1a4a0____1 VALUATION OF TOTAL CONSTRUCTION to 1�;(Ycl =ELECTRICAL $ AMPSERVICE PROGRESS ENERGY 0 W.R.E.C. ®PLUMBING ®MECHANICAL $ 1VALUATION OF MECHANICAL INSTALLATION 4�; 0 � =GAS ROOFING SPECIALTY OTHER �'D FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY DR Horton, Inc SIGNATURE REGISTERED FEE CURREN Address 112602 Telecom Drive; Tampa, FL 33637 License # I CBC039062 ELECTRICIAN I COMPANY [Strada Electric SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address IEOO::St Johns Pkw*y; Sanford, FL 32771 License# I EC13003715 PLUMBER RaCOMPANY Northwest Plumbing SIGNATURE REGISTERED / N FEE CURREN Y/N Address 6310 Mabelton Pay, St 1000; Mableton, GA 30126 License # ICFC1427137 MECHANICAL COMPANY Progressive Air Systems SIGNATURE REGISTERED Y/N FEE CURREN Address 7130 Meiahan Ct: New Port Richey, FL 34652 License #1 bAC033669 I OTHER COMPANY Brad McDonald Roofing SIGNATURE REGISTERED Y/N FEE CURREN Y I Address 7143 SIR 54; New Port Richey, FL 34653 License #I CC1 325833 RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Pen -nit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans wl Silt Fence installed, Sanitary Facilities & I dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (A/C upgrades over $7500) — Agent (for the contractor) or Power of Attorney (for the owner) would be someone With notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage) Driveways -Not over Counter if on public roadways..needs ROW 813-780-0020 City of ZephvrhiUs Permit Application Fax-813-780-0021 Building Department NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject m�ed" restrictions" which may he more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009, Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" ofthis application for which they wfl I be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as,may be due, will be identified at the time of pennitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County Ordinances, CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection -Cypress 'Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment, - Southwest Florida Water Management District -Wells, Cypress Bayheads, Wbtland Areas, Altering - Army Corps ofEngineem-8eeweUa.Docks, Navigable Waterways. - Deportment of Health & Rehabilitative Services/Environmental Health Unit-VVeUe, Wastewater Treatment' Septic Tanks. ' - USEnvironmental Protection Agency -Asbestos abatement. - Federal Aviation Authorib+F7unweyo. | understand that the following restrictions apply mthe use of fill: - Use offill isnot allowed inFlood Zone ''V"unless expressly permitted. . - If the fill material is to be used in Flood Zone ''A^, it is understood that a drainage plan addressing a ''compenoating volume" will be submitted at time of permitting which is prepared by o professional engineer licensed bythe State ofFlorida. - If the fill material is to be used in Flood Zone ''A^ in connection with e permitted building using stem wall construction, | certify that fill will be used only tofill the area within the stem wall. - If fill material is to be used in any area, i certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent propert|em, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. |f|omthe AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencingtm| | understand that a separate permit may be u|reufor electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A pen -nit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered OWNER OR AGENTk"'pdaj� CONTRACTOR Su scri ad and swo 71- his Subscribed and sworn to (or affirmed) before me this Who is/are personally known to me or has/have produced Who is/are personally known to me or has/have produced —as identification. —as identification. 471 Al (Y V�� Notary Public Commission No. U Name of Notary typed, printed or stamped HEATHER � commission #GG 90109 Expires May 3,2024 ^uo�«� Bonded mmmwdoxwmIFYm0*0 Commission 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department )ate Received Phone Contact for Permitting I MMoyes@drhortan.com rhortan.com it a a a N't a It Dwner's Name DR Horton Inc Owner Phone Number 1 813-549-1968 :)wner's Address112602 Telecom Drive; Tampa, FL 33637 Owner Phone Number F =ee Simple Titleholder Name ISame Owner Phone Number -ee Simple Titleholder Address I JOB ADDRESS I I LOT # SUBDIVISION Abbott Park (Zephyr Lakes) PARCEL ID# (OBTAINED FROM PROPERTY TAX NOTICE) NORK PROPOSED NEW CONSTR ADD/ALT SIGN DEMOLISH INSTALL REPAIR PROPOSED USE SFR COMM OTHER TYPE OF CONSTRUCTION BLOCK FRAME STEEL — ----- DESCRIPTION OF WORK BUILDING SIZE I SQ FOOTAGE HEIGHT JL IL it JL IL iL IL 3L AL IL k AL iL t k �L IL iL iL iL 4L JL WL 3L k JL iL �L k IL & IL IL IL IL iL JL AL JL IL IL I NIA BUILDING - 1 $ N/A VALUATION OF TOTAL CONSTRUCTION FN/A ELECTRICAL 1$ N/A AMP SERVICE PROGRESS ENERGY W.R.E.C. NIA PLUMBING $ N/A N/A MECHANICAL $ N/A VALUATION OF MECHANICAL INSTALLATION N/A GAS ROOFING SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y / N Address License # ELECTRICIAN COMPANY SIGNATURE REGISTERED YIN FEE CURREN N Address License # PLUMBER f COMPANY Lawn Medic Landscape & Irrigation SIGNATURE AN i! !!di REGISTERED Y/N FEE CURREN LILN _J Address 4827 Beauchamp Rd; Plant City, FL 33562 License# JSCC1311520841 MECHANICAL COMPANY SIGNATURE REGISTERED YIN FEE CURREN E7TK:F Address License #E:::::::= OTHER COMPANY SIGNATURE REGISTERED Y / N FEE CURREN Y I Address License # watts a was 111111942 92 all 111.11911111211111:9112-119222 19 14114t4iiisil as.]! RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction, , Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & I dumpster; Site Work Permit for subdivisions/large projects COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans wl Silt Fence installed, Sanitary Facilities & I dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (A/C upgrades over $7600) — Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences (Plot/SurveylFootage) Driveways -Not over Counter if on public roadways..needs ROW 03-780-0020 City of Zephyrhills Permit Application Fax-813-780-001 Building Department NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject ���restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" ofthis application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner', I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. CO NTRACTO R'SIOWN ERIS AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a pen -nit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be In compliance, Such agencies include but are not limited to: Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. Southwest Florida Water Management District -Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps ofEngineers-8eavvoUa.Docks, Navigable Waterways. - Deportment of Health & Rehabilitative Services/Environmental Health Unit40eUa, Wastewater Treatment, Septic Tanks. ' US Environmental Protection Agency -Asbestos abatement. - Federal Aviation Authnrity-Runwaya. | understand that the following restrictions apply tothe use nffill: - Use of fill is not o||ovved in Rood Zone Wr unless expressly permitted. - If the fill material is to be used in Flood Zone "A'', it is understood that o drainage plan addressing m "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed bythe State ofFlorida. - If the fill material is to be used in Flood Zone ^A" in connection with e permitted building using stem wm|| construction, I certify that fill will be used only to fill the area within the stem wall. ' If fill material is to be used in any area, | certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent propsrtieo, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots |eoa than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing un tmct| n | understand that aoopomte permitmay uorequired for electrical work, plumbing, signs, vmoa pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a perrnit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered 121ugglumiumm"Ifflom-M&F "Im ME S scri4ed and sv r,rTt ( ta&ffl frmeeKdK) Lbef ore mAhis Subscribed and sworn to (or affirmed) before me this Who islare personally known to me or has/have produced ��h_o i�/­arepersonally known to me or has/have produced as identification. as identification. Commission No.___ Name of Notary food, -printed or stamped HEATHER MUNDT CommWmo0GGS45400 NOExphmMay 3,2024 �"wv mr*wmWm*mNot" SWVm" Commission No. Name of Notary typed, printed or stamped NBO I , FT.E. shall be a mi-nirritim of 8"' above the road elevatiorn and an engineered site plan, I Lots shall be graded t(,,) comply with R401 .3 of the f7,B,('. 3. Compaction test required if 24" or more offill dirt is brought in at any one place. 4Tie in s,,irvey required bel'ore pouring concrete, 5� Driveways require a R,O,W. use pennit. All 4 sides of'drIves,,ay thru the sidewalk shall have expansion inaterial. 6, All setbacks shall be met, 7, All property markers shall be uncovered and marked at tunic; offirst inspection, 8, All A,D,A, requirements shall be inet, 9, No electric, plumbing, niechanical., or frarning shall be covered without an inspection arid approval first, 10, All Garages shall comply with section R3016 of the EBS'. (Fire Separation). 11, Appliances shall not be installed in a location where sufjJect to mechanical damage unless protected by approved baffiCI-S. M303.4 of the F.B,C, 12, NVater heaters shall comply with section P607.3 of the F,BF C, 13, Foundation supports for A/C units shall be raised at least 3" above f-inished grade, M 1308,1 14, Return air in all bedrooms. F,B,C, M 1620A 15, Smoke detectors are to be installed in accordance with R31 1A of the F,B.(', 16, All glazing requirements are to be in accordance with R308.4 of tire 17, All mearis of egress arc to be in accordance Nvith R3 I t of the F.B.C, 18, "Green gypsuni board"' shall not be Used as as backer in showers or tubs, R702A,2 F,B,C, 19, Combination-typc MVI breakers are required at all locations requiring an AF(I type breaker, 20, Carbon monoxide alarms will be required in new construction that uses Ilossil-burning heating or appliances or an atractied garage, They shall be installed in accordance with the F,B.C'. 2 1, All plumbing, mechanical, and electrical shall be separate from unit tO Unit. This includes all underground plumbing and electric. 22, All 2016 N,FI',C, Codes will be euirorced, 23,, Tamper- Resistant Receptacles in accordance with 4W 11 of the 2016 N E,C, 24, In accordance with the Land Development Code., lots shall be sodded before final at least 10 feet around the structure, 25, R403,5,3lot water pipe insulation Insulation for hot water pipe with a rniniMUM thermal resistance (R-value) of R-3 shall be applied to the following: Piping,,,/,, inch (191 mm) and larger in nominal diameter, Piping serving more than one dwelling unit. Piping located outside the conditioned space, Piping from the water heater to a distribution manifold, Piping located under a floor slab, Buried in piping. Supply and return piping in recirculation systerns other than demand recirculation systems, 25. Blowerfdoor test shall be provided before C.O. 26. all tinies. 27. ermit be i)re iaL 2& F.F.E.-Finished Floor Elevation F.B.C- Florida Building Code 6 th Edition R.O.W.-Right of Way A.D.A.- Americans with Disabilities Act N.E.C.- National Electric Code (2016) PLOT PLAN DESCRIPTION:(AS FURNISHED) LOT 29, BLOCK 12, ZEPHYR LAKES SUBDIVISION PHASE 4B AS RECORDED IN PLAT BOOK 85, PAGE(S) 126-128, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. 1" = 30' GRAPHIC SCALE O 15 30 ON LOT CALCULATIONS LOT = 6,250 SQ. FT. LIVING AREA = 1,104 SQ, FT. GARAGE = 437 SQ. FT. ENTRY = 111 SQ. FT. LANAI = 0 SQ. FT. PA110 = 80 SQ. FT. DRIVEWAY = 0 SO. FT, A/C PAD = 12 SQ. FT. WALKWAY = 440 SQ. FT. IMPERVIOUS = 35% = 2184 SQ. FT. SOD = 4,066 SQ. FT. OFF LOT CALCULATIONS RIGHT OF WAY = 650 SQ. FT. DRIVE APRON = 152 SQ. FT. PUBLIC S/W = 250 SQ. FT. SOD = 248 SQ. FT. TOTALS AREA = 6,900 SQ. FT. DRIVEWAY = 152 SQ. FT. SIDEWALK = 690 SQ. FT. SOD = 4,314 SO. FT JULI I °a BROAD POINTS DRIVE I o TRACT "A" WAY Ja1 50' WIDE PRIVATE RIGHT OF 1fl PI f a (REFERENCE BEARING) S89'53'26"E _ 314.94' — PCP l a jl\ — 283.36' 31.58r;1 I w I I ONI Z I I I _ Z N,- .. k —' v O O L6 w LOT 28 BLOCK 12 z n':. z "'Sc W t.LOOD 1s3hllE "x" FRONT: 22' GARAGE: 27' REAR: 13' SIDE: 5' SIDE STREET: 15' NOTES: 1. PROPOSED ELEVATIONS SHOWN HEREON ARE BASED ON THE APPROVED ENGINEERING PLANS PREPARED BY HAMILTON ENGINEERING & SURVEYING INC. 2. ELEVATIONS ARE BASED ON NAVD 1988 DATUM. THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF THE PROPOSED STRUCTURE. THE CONTRACTOR AND/OR OWNER ARE REQUIRED TO VERIFY ALL SETBACKS, BUILDING DIMENSIONS, AND LAYOUT SHOWN HEREON PRIOR TO ANY CONSTRUCTION. THIS IS NOT A SURVEY THIS IS A PLOT PLAN ONLY FLOOD NOTE: I HAVE EXAMINED THE F.I,R.M. MAP N0. 12101CO293F, DATED 09/26/2014, AND FOUND THE SUBJECT PROPERTY APPEARS TO LIE PARTIALLY IN ZONE "X" & "A". ZONE "X", AREAS DETERMINED TO BE OEU'fTSERIMINFTHDE 0 BE SPECIAL FLOOD HAZ RD AREASOSUBJECT TOSS INUNDATION BY THE 1% ANNUAL CHANCE FLOOD EVENLTHE SURVEYOR MAKES NO GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE CONTACT THE LOCAL F.E.M.A. AGENT FOR VERIFlCATION. BEARING BASIS: BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF BROAD POINTE DRIVE BEING S89'13'28"E. PER PLAT. (FIELD DATE:) SCALE: i" =.30 FEET APPROVED BY: JB 210733 LOT 29, BLOCK 12 JOB NO. DRAWN BY; DSB VA .'10' UE -;- - - - - - --- -J" N �DRIVE�,. `COVERED ENTRY U PROPOSED N ti N HAYDEN r T14 d' 4EHB — "K" FINISHED FLOOR ELEVATION=92.10' 39.67' 39.7' 5.2' o A/C' m 1. �10.0'c O AT10 O LOT 29 10 BLOCK 12 6,250 SO. FT t DRAINAGE TYPE A 10' PLE ZEPHYRHILLS COLONY COMPANY PLAT BOOK 1, PAGE 55 Ammml�7 — — BUILDING SETBACK LINE — CENTERLINE — — — RIGHT OF WAY LINE PROPOSED ELEVATION PROPOSED DRAINAGE FLOW CONCRETE A/C AIR CONDITIONER S/W SIDEWALK ir►�(r1� )yl}i�`�„t��k A191�I51'l�At+@�k4if;iF� :�� i1 ' 1FI4� & f4��1� «�N4�i RE HTT U WAY LOT 30 BLOCK 12 ZEPHYR LAKES SUBDIVISION PHASE 4D PLAT BOOK 84, PAGE 82 PI POINT OF INTERSECTION PC POINT OF CURVATURE PT POINT OF TANGENCY RP RADIUS POINT PRC POINT OF REVERSE CURVATURE PCP PERMANENT CONTROL POINT TYP TYPICAL'.. CS CONCRETE SLAB IF) PER PLAT PBO CALCULATED PLAT BOOK PGS PAGES SO' FT, SQUARE FEET F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY RI.R.M. FLOOD INSURANCE RATE MAP NAVD NORTH AMERICAN VERTICAL DATUM D&UE DRAINAGE & UTILITY EASEMENT DE DRAINAGE EASEMENT UE UTILITY EASEMENT (PUBLIC) PLE PRIVATE LANDSCAPE EASEMENT SURVEYOR NOTES: 1. THE SURVEYOR HAS NOT ABSTRACTED THE LAND SHOWN HEREON FOR EASEMENTS, RIGHT OF WAY, RESTRICTIONS OF RECORD WHICH MAY AFFECT THE TITLE OR USE OF THE LAND. 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCATED EXCEPT AS SHOWN. 3. NOT VALID WITHOUT THE AUTHENTIC ELECTRONIC SIGNATURE AND THE AUTHENTIC ELECTRONIC SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. ae'!"V l'IUse, Dlgitly'gned byJames Bolemar DN:c .US st Florida,) Orantlo, —Amercan scorayn9&PAappng dSurveyor. a 'AI.761. an@asmcorporate mm FOR Date 20210e2108:2447 �0400 THE ��T�dr'nr�uunlatiw�A"�Av� Adobe Acrobat version t A29 FIRM JAMES W. BOLEMAN PSM# 6485 DATE CITY OF BUILDING , ZEPHYRHILLS "NOTICE" DEPARTMENT OF ADDITION OR CORRECTION ADDRESS DATE PERMIT# '-) S --170 6zc-lied tj I i - t�" 311" THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be made before the job will be accepted. It is unlawful for any Carpenter, Contractor, Builder, or other persons, to cover or cause to be covered, any part of the work with flooring, lath, earth or other material, until the proper inspector has had ample time to approve the installation. AFTER CORRECTIONS ARE MADE CALL 780-0020 F:9R/RE-!IS TION INSPECTOR