Loading...
HomeMy WebLinkAbout21-3092City of Ze.phwhills 5335 Eighth Street Zephyrhills, FL 33542 Phone: (813) 780-0020 Fax: (813) 780-0021 IWO ELCMISC-003092-2021 L— Issue Date: 10/25/2021 REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. RnMETTMIT-n 0 0 accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRA OR SIGNATURE PE r1IT OFFICEV PERN ;�IRES IN 6 MONTHS WITHOUT APPROVED INSPECTION lag", 813-780-0020 City of Zephyrhills Permit Application voc Fax-813-780-0021 Building Department 03ji JL 3 e? � A Date Received Phone Contact for Permitting [( 813 0086 648 -_ Owner's Name Nelia Clark Owner Phone Number 1(813)385-786= Owner's Address [5308 Tangerine Dr Owner Phone Number Fee Simple Titleholder Name �mmOwner Phone Number Fee Simple Titleholder Address JOB ADDRESS 15308 Tangerine Dr Zephyrhills FL USA 33542 1 LOT # SUBDIVISIONZEPHYR HElC;HTS� PARCEL [D#I 12-26-21-0040-00400-0160 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD/ALT SIGN DEMOLISH INSTALL REPAIR PROPOSED USE SFR 000MM OTHER TYPE OF CONSTRUCTION BLOCK Q FRAME STEEL DESCRIPTION OF WORK Installation of a roof -mounted photovoltaic solar panel system. BUILDING SIZE [ 7 SO FOOTAGE HEIGHT [:= x x VIL-K VVILIL-VIL VX X IT V VV_VX it IT x Ir VV'x'VVXx Vx 1EXIII VAT V x ILIL-x ALA A _V V VX'x'V'V1L VA"`V'Vx_VV It I V ®BUILDING 1$ (p,W.C2 -�41 VALUATION OF TOTAL CONSTRUCTION MELECTRICAL AMP SERVICE 0 PROGRESS ENERGY W.R.E.C. =PLUMBING =MECHANICAL 1$ VALUATION OF MECHANICAL INSTALLATION =GAS ROOFING SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY Sunrun Installation Services, Inc. SIGNATURE �EGiSTERED Y/N FEE CURREN Y/N Address 80 Tampa W. Blvd, Tampa FL 'VZa:IA I License# I EC 13007964 ELECTRICIAN COMPANY Sunrun Installation Services, Inc. SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address 5r280 Tampa W. Blvd, Tampa FL 33634 Licerse# EC 13007964 PLUMBER I COMPANY [_ SIGNATURE REGISTERED Y / N FEE CURREN L_X_LN _J Address License # MECHANICAL COMPANY E SIGNATURE REGISTERED �Y / N FEE CURREN / N� Address License# OTHER COMPANY E SIGNATURE l REGISTERED Y i N FEE CURREN Y% N Address License # RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms, R-O-W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 clumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2600, a Notice of Commencement is required. (A/C upgrades over $7600) Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage) Driveways -Not over Counter if on public roadways..needs ROW 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009, Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. Southwest Florida Water Management District -Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses, Army Corps of Engineers -Seawalls, Docks, Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency -Asbestos abatement Federal Aviation Authority- Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone W" unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a °compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. I MM I Z Ltm livil"m 101 M 11711 ag-1,61"Figiri 1:4 M Im ILOAk�Lolwi:m:j '103:2 illarm I AW4111 10 11-40 1 ORILOX01 Z3 IF -A I � 0 21 0 0 to me or has/have pr as identification. Notary Public ssion No, COI , , i ii &.� JOSHUA LONG My COMMISSION #HH1 31615 EXPIRES: MAY 20, 2025 Bonded through 1st State Insurance Sub crib d and sVWJVTi!�9ffirrd) before me this A_Q�by` 'o J0411141-n'— Who i . s/ , are personal kknown t� me or has/have produced as identification. Notary Public c m is s, on �,.. 131 Wa—m a Notary typed, printed "m I MY JOSHUA LONG I ECXOPIMMIS N #HH131615 n RES: Y20,2025 ded through ist State Insurance October 13, 2021 Subject : Structural Certification for Proposed Residential Solar Installation Job Number: 802R-308CLAR, Rev A Client: Nelia Clark Address: 5308 Tangerine Dr, Zephyrhills, FL, 33542 Attn: To Whom It May Concern c .58 un Ast,a v.1run WS CAT 1 kAE No 84 23 STATE Of 5� C) 40, %NA1 1m\\\ Signed on, 1011312021 A field observation of the existing structure at the address indicated above was performed by a site survey team from SUnrun. Structural evaluation of the loading was based on the site observations and the design criteria listed below. Design Criteria: 2020 FBC (7th Ed,) Amendments to 2018 IRC/IBC/IEBC, 7-16 ASCE & 2018 NDS, Basic Wind Speed V = 138 mph, Exposure B Ground Snow Load = 0 psf Based on this evaluation, I certify that the alteration to the existing structure by the installation of the PV system meets the requirements of the applicable existing and/or new building code provisions referenced above, Additionally, I certify that the PV module assembly including all attachments supporting it have been reviewed to be in accordance with the manufacturer's specifications. 225 Bush St. Suite 1400 San Francisco, CA 94104 SdOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS SYSTEM SIZE: 680OW DC, 480OW AC - ALL WORK SHALL COMPLY WITH 2020 FBC (7th Ed,) Amendments F­ SOLAR MODULES PAGE# DESCRIPTION MODULES: (20) HANWHA Q-CELLS: Q.PEAK DUO to 2018 IRC/IBC/IEBC, MUNICIPAL CODE, AND ALL MANUFACTURERS'LISTINGS SERVICE ENTRANCE PV-1.0 COVER SHEET BLK-G6+ 340 AND INSTALLATION INSTRUCTIONS. T "E'-1 I ------ PV-2.0 SITE PLAN INVERTERS: (20) ENPHASE ENERGY: 107-60-2-US PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017. RACKING: SNAPNRACK RLU-1 RL UNIVERSAL, SPEEDSEAL MP MAIN PANEL RV-10 LAYOUT TRACK ON COMP, SEE DETAIL SNR-DC-00436 a ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017. d PV-4.0 ELECTRICAL SNR MOUNT PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY SP SUB -PANEL PV-5.0 SIGNAGE GROUNDED IN THE INVERTER, SYSTEM COMPLIES WITH 6901,35. SNR MOUNT & SKIRT MODULES CONFORM TO AND ARE LISTED UNDER UL 1703- LC PV LOAD CENTER CHIMNEY Po INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741 SR SUNRUN METER ATTIC VENT RACKING CONFORMS TO AND IS LISTED UNDER UL 270I 1 FLUSH ATTIC VENT • SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE 1, OR TYPE 11 S DEDICATED PV METER MODULES, ARE CLASS A FIRE RATED. IPVC PIPE VENT - RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL INV INVERTER(S) METAL PIPE VENT CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690. 1 2(l), T-VENT * CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690,31 (G). F—AC-1 AC DISCONNECT(S) E�H SATELLITE DISH * ARRAY DO CONDUCTORS ARE SIZED FOR DEBATED CURRENT, DC DO DISCONNECT(S) FIRE SETBACKS * 10,52 AMPS MODULE SHORT CIRCUIT CURRENT. * 16.43 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (a)& 690.8 (b)], CB IQ COMBINER BOX HARDSCAPE F 7 INTERIOR EQUIPMENT PL— PROPERTY LINE L _J SHOWN AS DASHED SCALE:NTS A AMPERE sunrun AC ALTERNATING CURRENT ENGINEER ADDRESS AFCI ARC FAULT CIRCUIT INTERRUPTER 225 BUSH SD, SUITE 1400 SAN FRANCISCC, C.A. 94104 AZIM AZIMUTH P 94e-3a-"_0993 VICINITY MAP COMP COMPOSITION EC13007964 DC DIRECT CURRENT (E} EXISTING 520s TAMPA Pr BLVD, TAMPA, FL 33634 FAXESS ENERGY STORAGE SYSTEM FAX 0 EXT EXTERIOR INT INTERIOR CUSTOMER RESIDENCE: MAG MAGNETIC LINDA TERRACIANO MSP MAIN SERVICE PANEL 7851 BROAD POINTE DR, No (N) NEW ZEPHYRHILLS, FL, 33541 NTS NOT TO SCALE TEL. (908) 267-6265 'd Oc ON CENTER STATE OF W APN/TMK #: APN: 0" PRE -FAR PRE -FABRICATED Z­ 35-25-21-0150-01500-0200 %41 PSF POUNDS PER SQUARE FOOT PROJECT NUMBER� `P PV PHOTOVOLTAIC ANAL 802R-851TERR RSD RAPID SHUTDOWN DEVICE TL TRANSFORMERLESS DESIGNER: STRUCTURAL ONLY (415) 580-6920 ex3 TYP TYPICAL v Signed: 10/01/21 V VOLTS MD ALAM W WATTS nat,zlephy, U O3S SHEET REVI NAME DATE COMMENTS COVER SHEET REV:A 30-09-2021 PAGE PV-1.0 PL (E) G PL E VV tV No A4923 PL STATEOF 0/11111\0 Signed: 10/01/21 ROOF INFO FRAMING INFO Name Type Height Type Max Span Spacing OC Detail AR-01 COMP SHINGLE - RLU 1 -Story 2X4 PRE -FABRICATED TRUSSES 6'- 6" 24" RL UNIVERSAL, SPEEDSEAL TRACK ON COMP, SEE DETAIL SNR-DC-00436 DI - AR-01 - SCALE: 1/8" = V-0" PITCH: 26' AZIM: 181' 7 ATTACHMENT INFORMATION Max Landscape Max Landscape Max Portrait Max Portrait OC Spacing Overhang OC Spacing Overhang 6'- 0" 2'- 4" 4'- 0" 2'- 0" 11 0\\\kl I I ////,/ VA E No,84923 % Z7 ' C)STATE OF tag - ORkO Z_ 0/11111wO Signed: 10/01/21 DESIGN CRITERIA Configuration MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 0 PSF WIND SPEED: STACKED 138 MPH 3-SEC GUST. S.S.LAG SCREWS: 5/16": 2.5" MIN EMBEDMENT STRUCTURAL NOTES: • INSTALLERS SHALL NOTIFY ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES OBSERVED PRIOR TO PROCEEDING W/ INSTALLATION, • IF ARRAY (EXCLUDING SKIRT) IS WITHIN 12" BOUNDARY REGION OF ANY ROOF PLANE EDGES (EXCEPT VALLEYS), THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANi REDUCED WITHIN THE 12" BOUNDARY REGION ONLY AS FOLLOWS: ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED BY 50% ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS 3 ENGINEER ADDRESS 222 BUSH ST. SUITE 1400 SAN FRANCISCO, CA 94104 P 949-383-0993 EC13007964 5208 TA',0PAA" BLVD. TAMPA, FL 33634 PHONE 0 FAX 0 CUSTOMER RESIDENCE: LINDA TERRACIANO 7851 BROAD POINTE DR, ZEPHYRHILLS, FL, 33541 TEL. (908) 267-6265 APN/TMK #: APN: 35-25-21-0150-01500-0200 PROJECT NUMBER: 802R-851TERR DESIGNER: (415) 580-6920 ex3 MD ALAM SHEET LAYOUT REV: A 30-09-2021 SEE SITE PLAN FOR NORTH ARROW PAGE PV-3.0 I METER DUKE ENERGY 4418097 UTILITY GRID EXISTING f 150A MAIN ( BREAKER `t (END FED) EXISTING EXISTING 200A —• °— 125A SUB MAIN :— PANEL FACILITY — PANEL LOADS (E)30A SUB-4-GROUND (N) 25A PV FEEDER BREAKER AT BREAKER OPPOSITE END OF BUSBAR 20A BREAKER [A] 20A BREAKER [B] JUNCTION BOX OR EQUIVALENT CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (2) 12 AWG PER. ENPHASE Q CABLE BRANCH NONE (1) 8 AWG BARE COPPER 2 3/4" EMT OR EQUIV. (4) 10 AWG THHN/TH -2 NONE (1) 8 AWG THHN/THWN-2 3 3/4" EMT OR EQUIV. (2) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 E EXISTING NODULE CHARACTERISTICS HANWHA Q-CELLS: Q.PEAK DUO BLK-G6+ 340: 340 W OPEN CIRCUIT VOLTAGE: 40.66 V MAX POWER VOLTAGE: 33.94 V SHORT CIRCUIT CURRENT: 10.52 A Q PEAK DUO BLK-G6+ 340 MODULES AND t MICRO -INVERTER PAIRS (20) ENPHASE ENERGY: IQ7-60-2-US (1) BRANCH OF (10) MICRO -INVERTERS [A] (1) BRANCH OF (10) MICRO -INVERTERS [B] cEN 8423` , : STATE OF pj//4/€11110 \ STRUCTURAL ONLY Signed: 10/01/21 ELECTRICAL SHOCK HAZARD TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): CEC 2019: 690A 3(B), NEC 2017: 690A 3(B) • LABEL LOCATION: ADJACENT TO PV BREAKER (IF APPLICABLE). PER CODE(S): CEC 2019: 705.12(13)(2)(3)(b), NEC 2017: 705.12(B)(2)(3)(b) PHOTOVOLTAIC SYSTEM COMBINER PANEL I DO NOT AID LOADS I LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF APPLICABLE). PER CODE(S): CEC 2019: 705.12(B)(2)(3)(c), NEC 2017: 705.12(13)(2)(3)(c) SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL, PER CODE(S): CEC 2019: 705.12(B)(3'). NEC 2017:705A 2(B)(3) LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): CEC 2019: 690.54, NEC 2017: 690.54 LABEL LOCATION: INSTALLED WITHIN T OF RAPID SHUT DOWN SWITCH PER CODE(S): CEC 2019: 690.56(C)(3), NEC 2017: 690.56(C)(3), IFC 2€312: 605.11.1, IFC 2018: 1204.5.3, CFC 2019: 1204.5.3 TURN RAPID SHUTDOWN SWITCH TO THE "OFF" HAZARDPOSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S): CEC 2019: 690.56(C)(1)(a), NEC 2017: 690.56(C)(1)(a) NOTES AND SPECIFICATIONS: • SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 ARTICLE 110.21(B); UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. • SIGNS AND LABELS SHALL_ ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. • LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. ® LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. • SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535A-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. • DO NOT COVER EXISTING MANUFACTURER LABELS. ,����t416I1f111/7, No 84923 ' STATE OF' - �ffZa 0 AL �\\\� STRUCTURAL ONLY