HomeMy WebLinkAbout21-3109City of ZepIII hyrhilis 1 5335 Eighth Street Zephyrhills, FL 33542 Phone: (813) 780-0020 Fax: (813) 780-0021 nomiam I 'BAR-003109-2021 Issue Date: 11/14/2021 1 REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies, 1,111111RIFIT IIwjIj�II1jIpjIj1' accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNATURE PE IMIT OFFICEt) PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION 1:1 -10I-J Z101 �, UT'11;n 9: 14 Ikit.;a MELROSE, Project Ref. [4519611413200 Moulden Hollow Drive Richard Edward Spears Zephyrhills FL 33540 Dear Richard Edward Spears, I am pleased to inform You that the Hidden River Homeowners Association Architectural Review Committee has approved your application for the listed project item(s): screened patio -application is approved as submitted. The approval is contingent upon compliance with the specifications set forth in the approved application. If your change or addition requires a county, city or state I permit, it must be obtained before construction. at will make a fine addition to our community -and look forward to its completion. We feel this improvernei t a(7 ) 1�3461 or via email � o78 ffic6 at 27 1 a= The Melrose Management Partnership Review Committqe Hidden River Homeowners Association 1600 West Colonial Drive - Orlando, FL 32804 - Phone:(407) 228-4181 ® Fax: (407) 228-4171 - With offices throughout Orlando �1#•. 1. 1. . 9061M 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building (Department Date Received s Phone Contact for Permitting It * x I I Owner's Name 4 Lf" SPEA10-S Owner Phone Number Owner's Address I 3(400 Oo\.) 1&174.� Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 00014z'i LOT # SUBDIVISION PARCEL to# 1,J Vd CU10 0X6C '0 L 0 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTRF-I ADD/ALT SIGN 0 0 DEMOLISH INSTALL REPAIR PROPOSED USE 0 SFR COMM 0 OTHER TYPE OF CONSTRUCTION BLOCK FRAME STEEL DESCRIPTION OF WORK I SQFOOTAGE [ram` �_ HEIGHT =ELECTRICAL Is -1 AMP SERVICE PROGRESS ENERGY = W.R.E.C. =PLUMBING =MECHANICAL VALUATION OF MECHANICAL INSTALLATION =GAS ROOFING = SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY SIGNATURE ­74 REGISTERED �N FEE CURREN Address License # ELECTRICIAN COMPANY SIGNATURE REGISTERED L_)LL N _J FEE CURREN I Address License # PLUMBER COMPANY SIGNATURE L REGISTERED _I±N _J FEE CURREN Address License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/N FEE CURREN L11 N J Address License# OTHER COMPANY SIGNATURE REGISTERED L_Y_LN _J FEE CURREN L_y _LN_j Address License # RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. *—PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (A/C upgrades over $7500) - Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage) Driveways -Not over Counter if on public roadways..needs ROW 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions, UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the 'contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County, TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance, Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances, CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law —Homeowners Protection Guide' prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. Southwest Florida Water Management District -Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers -Seawalls, Docks, Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency -Asbestos abatement. Federal Aviation Authority -Runways. I, understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "N' in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required, If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned, WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY, IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOU��ND�R OR AR( ��"�ORNEY BEFOR .RECORDING YOUR NOTICE OF CO MEN E ENT. FLORIDA JURAT (F.S. 117.03) OWNER OR AGENT CONTRACTOR Subscribed and sworn t7tpr aff 9d) bef th' Subscribed and sworn to gr affirmed) is Mr T�g me by T b 12 ( � Who is/are personally known to me or has/have produced Who is/are personally known to me; or has/have produced as identification. as identification. Public Commission Commission Name of Notary typed, printed or stamped Name of Notary typed, printed or stamped Public INSTR#2021230973ORBK10471 PG128 Page 1 of 2 10/27/2021 01:24 PIVI Rept: 2370623 Rec: 18.50 DS: 0.00 IT: 0.00 Nikki Alvarez-Sowles, Esq., Pasco County Clerk & Comptroller Permit NO. Parcel ID No Y-d6 /0 1710, I NOTtCE OF COMMENCEMENT State of :t N�R 4 &4N- County of THE UNDERSMED hereby ohm notice Mat imp 'Wigt will 61 jog I DescdpWn of Property- Parcel Identification Stmet Address: 02ol) jj,,� J- -.4 ,bllo 2. GeneralDesorlptionof Improvement 3. Owner Info or Lessee Information it the Leswe contracted for the Improvement �jtj�o, , 'So eAA_S 'Address city state Interest in Property: Name of Fee Simple Titleholder. (If different from Owner listed above) Add scVZeA-6 CRY state 4. contractor. Name �-q 19 Cfwtft -o& 7-'1,4 .1 eL V, (I j Oct 3 Address 3 '2,W- State Contractoes Telephone No.: 5. Surety: Aj G^, Name Address MY State Amount of Bond: Telephone No.: 6. Lender. tO Name Address CRY state Lender's Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notilices or other documents may be served as provided by Section 713.13(1XaX7). Florida Statutes: fj L-or Name Address CRY state Telephone Number of Designated Person: ... a. In addition to himself, the owner designates of toreceive a copy of the LWWs Notice as provided In Seclion 713.13(1Xb), Florida Statutes. Telephone Number of Person or Entity Designated by Owner 9. Expiration date of Notice of Commencement (the aWratlon date may not be before the completion of construction land final payment to the contractor, but will be one year from the date of recording unless a different date Is specified}: 6 XdA7 AS 641V" Under penalty of perjury. I declare that I have read the, foregoing notice of commencement and that the facts stated therein am true to the best of my knowledge ancl belief. STATE OF FLORIDA —COUNTY O.F.PASCO f 6.sly Owner6r e. n re of•;;;1.7 or Ownses or LesseWs Aulhorized fn 101. fill Direclor/P.Ittnerriz 0 O, ager M ".— "A11111,77Z '. The foregoing Instrument was acknowledged before me this day of _. 20 _ by as (type of authority, e.g., officer, trustee, attorney in fact) for (name of party on behalf of whom Instrument was executed). Notary Signature Name (Print) wpdstWbo%/notIosocmm--Lpc053048 I The foregoing instrument was acknowledged before me this day f 0 CJ 0 C)r 0 , 20 1-, by means of ephysi�l presence or C] online notarization 4-i i efperson acknowledging). 0 sonally known to me [��Produced Ide fication Type of ld /fil.�atilnProduc@_I_j�c)(-kckq,��rkoe-t" LC'et/IS4a Notary signature C) 0, Z J*My Comm. EY49MA Z j April 15,2023 No. GG 323832 N OF f 0 Attached Document • ar -WSM Type or Title of Document C> C e 0 4 ce> YY1 r'Vi e r) C �Y'Y' en4 Document Date 10 /D4 M State Of Florida, County Of Pasco This is to certify that the foregoing is a true and correct copy of the document on file or of puOtt blic record in this office. Wi'tn my hani Ind ol ;,all seal this day of- Ni ki Alvare ZERM3E=F -1- 0 2020 Web Fargo Bank, NA AD rights reserved. DSG5350FU595501 (Rev 05- 05/21) I ---u tUWARDWARS, JET AND 1140A MAR"'tI&I Spf,-Ap� 0 tOT �03 AD 5, 7 0 I A k V Eli '14, ex is x N 6191*36Al" Po 101 10� )ESCRIPTION: )1 104, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE ONE A". S RECORDED IN PLAT BOOK 074, PACES 101 THROUGH 121, F THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA, i4 2- C T -------f P Vcfk, r. L OWE S T FLOi. LIVING AREA GARAGF AR� EIEVAT;ONS NATIONAL GE DAILPlA OF 7� LEVLL000f, 4PPARUNT FLOOD HA?ARD ZONES "X- COMMUNITY PANEL NO. 12101C 0458 F EFTIECTt rc 7WE 9 t-71M OAIA, (())* OECD DATA, (M)= Mf:A!;k)Rfi) OAIA, (il PI A I [)ATA, fy-- (J:IfFJJNF_ A/C, AIR L4A'a rff- 0<4 "MORD HEAP '4,, (:Lf C, - RD, cfffj,� C f I C, '0 l" , A'., w , % -.1Y P n M., C()�4(Rr IF IfAFNI, FfPPz R)AINO IR('N r41PF, ;Q, !P�,W R()T), ')CR F I! VAT4-)N MAS �R, 0;;q,jAt RL(f;4() !10,:W PF-3- Pt AT t3tf�, VCPPj P'jt V R IW-, RtCmT OF WAY, R^ f4AOiU-�>R S[ T I, '?" 490 At CAP No 4.13, C,`ljkS--; SA N 4A3S, is I VA iLN JOHN R. BEACH ASSOCIATES, INC. m C, 0�i AND MAP-1CPSwr 1 ,f P; fil f? Ili Y PiA 1 fifl$ 1,A, tif PC 1,VC _jt LlfAP%f AN) klt 1 11 ;,1, , E e r�WJAAP FLORIDA 34f;77 JRUR 1' TAl,()ARF),3 A; '��k F,�,*TH A 1-' F" (Hl31 4 t27f, i At (81,5) H111) fi3,'() Rf)! I, �� S, nN A! iN Tit AL" m Iv IRA I, •f oof A',D 0-01c .TATIIJ',f%--- , k ORIDA .', 1, A J f MAL 4/13/18 E)Aff) Tit IN 2/lfl1" 14*8 General Notes A. CONCRETE & FOUNDATION DESIGN: I. ALL CONCRETE GRADE BEAMS AND FOOTINGS SHALL BE 3000 PSI MINIMUM. 2. ALL CONCRETE FILLED SUPPORTED SLABS SHALL BE 2500 PSI MINIMUM, 3 1/2" NOMINAL THICKNESS. 3. FIBERMESH 3/4" PER CUBIC YARD MIN. MEETING APPROPRIATE ACI AND ASTM REQUIREMENTS MAY BE USED IN LIEU OF WELDED WIRE MESH 4. ALL SLABS ON GRADE SHALL BE 4" THICK WITH FIBERMESH. 5. ALL REINFORCING SHALL CONFORM TO ASTM A615, BE GRADE 60 (60 KSI MIN.) DEFORMED BARS, #3 BARS MAY BE GRADE 40 6. ALL OVER POUR CONCRETE FILLED SUPPORTED SLABS SHAI.,L BE 3000 PSI MIN., 2" MINIMUM. THICKNESS. 7. SOIL BEARING PRESSURE SHALL BE A MINIMUM OF 1500 PST. 8. THE CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING: OPC (PORTLAND CEMENT TYPE I, ASTM C 150). AGGREGATES - #6 STONE, ASTM C 33 SIZE NO. 67 LESS THAN 3/4". AIR ENTRAINING �/- I% - ASTM C 260, WATER REDUCING AGENT - ASTM C 494. CLEAN POTABLE WATER. OTHER ADMIXTURES SHALL NOT BE PERMITTED. 9. METAL WELDED WIRE SHALL CONFORM TO ASTM A 185. 10. PREPARE & PLACE CONCRETE ACCORDING TO AMERICAN CONCRETE INSTITUTE MANUAL STANDARD PRACTICE, PART 1, 2, & 3 ALONG WITH HOT WEATHER CONDITIONS RECOMMENDATIONS. 11. IF UTILIZING EXISTING CONCRETE FOR FOUNDATION, CONCRETE SHALL BE A MINIMUM OF 4" IN THICKNESS. VISIBLY FREE OF ANY STRUCTURAL EXCESSIVE CRACKING, SPALLING OR OTHER DETERIORATION. R. MASONRY: ]_CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON 'TYPE M OR S MORTAR. 2-ALL MORTAR SHALL BE OF TYPE M OR S. 3.ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 3/8". 4.PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS 5'-0" IN HEIGHT. C. ALUMINUM: 1. ALL STRUCTURAL ALUMINUM SHALL CONFORM TO THE. MINIMUM REQUIREMENTS OF 6005-T5 FOR ALLOY WITH A MINIMUM THICKNESS OF 0.040" FOR SUPPORTING MEMBERS. 2. WHERE KICK PLATES ARE USED A MINIMUM THICKNESS OF 0.024" SHALL APPLY. 3. STRUCTURAL ALUMINUM DESIGN CONFORMS TO "PART 1-A - SPECIFICATIONS FOR ALUMINUM STRUCTURES - ALLOWABLE STRESS DESIGN" OR "PART I-B - SPECIFICATIONS FOR ALUMINUM STRUCTURES - BUILDING LOAD AND RESISTANCE; FACTOR DESIGN" OF THE ALUMINUM DESIGN MANUAL PREPARED BY THE ALUMINUM ASSOCIATION, INC.WASHINGTON D.C. THE FLORIDA BUILDING CODE 7TH EDITION ( CHAPTER 16 STRUCTURAL DESIGN & CHAPTER 20 ALUMINUM). 4. WHERE ALUMINUM COMES INTO CONTACT WITH STEEL, OR PRESSURE TREATED LUMBER PROVIDE DIELECTRIC SEPARATION. 5. ALUMINUM MEMBERS SHALL BE STITCHED WITH NO LESS THAN #10 SMS 6" FROM THE ENDS AND 12" ON CENTER, IF USING 912 SPACING MAY BE 24" ON CENTER. 6. VINYL AND ACRYLIC PANELS SHALL BE REMOVABLE_ THEY SHALL BE IDENTIFIED WITH A DECAL ESSENTIALLY STATING "REMOVABLE PANEL SHALL BE REMOVED WIZEN WIND SPEEDS EXCEED 75 MPH". DECAL SHALL BE PLACED SO IT IS VISIBLE WHEN PANEL IS INSTALLED. 7. 1 "X2"X0.045" NON-STRUCTURAL MEMBERS SHALL BE ATTACHED TO HOST WITH 1/4"0 X 1-3/4" EMBEDMENT & 24" O.C. MASONRY SCREW FOR CONCRETE & EQUIVALENT SIZE WOOD SCREW WHEN IN WOOD & #FOX 1/2" EMBEDMENT SMS OR TEK SCREWS IN ALUMINUM MEMBERS TYPICAL. D. FASTENERS: 1. ALL LAG BOLTS SHALL CONFORM TO STAINLESS STEEL TYPE 300 18-8, WITH STANDARD FLAT WASHER UNLESS MANUFACTURER GALVANIZES BOLTS SPECIFIES FOR USE WITH ACQ PRESSURE TREATED WOOD. 2, HEX BOLTS HAS TO BE ASTM A 325, PLATED WITH STANDARD FLAT WASHERS AND NUTS. 3. ALL CONCRETE SCREWS SHALL BE, SIMPSON, HILTI, RAWL, TAPCON, REDHEAD, DYNABOUL PORTECT OR APPROVED EQUAL. 4. ALL METAL TIES AND ASSOCIATED ACCESSORIES SHALL BE HOT DIPPED GALVANIZED_ 5_ ALL LAG BOLTS SHALL HAVE A MINIMUM EMBEDMENT OF 8X BOLT DIAMETER INTO STRUCTURAL FRAMING (G=.42 MIN.). 6. LAG BOLTS AND SCREWS INTO WOOD FRAMING SHALL BE PROVIDED WITH PILOT HOLES HAVING A DIAMETER NOT GREATER THAN 70 PERCENT OF THE THREAD DIAMETER OF THE BOLT OR SCREW. ALL LAG BOLTS AND SCREWS SHALL BE INSERTED IN PILOT HOLES BY TURNING AND UNDER NO CIRCUMSTANCES BY DRIVING WITH A HAMMER. 7. ALL EXPANSION ANCHORS SHALL BE DESIGNED IN ACCORDANCE WITH THE SPECIFIC MANUFACTURER'S REQUIREMENTS AND ALLOWABLE LOADS AND SHALL ONLY BE APPLIED IN CONDITIONS ACCEPTABLE TO MANUFACTURER. FASTENERS SHALL BE A MINIMUM OF SAE GRADE #5 OR BETTER ZINC PLATED. 8. ALL FASTENERS CONNECTING ALUMINUM COMPONENTS OR PRESSURE TREATED LUMBER ARE STAINLESS STEEL TYPE 300 18-8, UNLESS MANUFACTURER GALVANIZED BOLTS SPECIFIES FOR USE WITH ACQ PRESSURE TREATED WOOD, OR OTHERWISE NOTED ON PLANS. 9. ALL FASTENERS SHALL COMPLY WITH ASTM Al 53. 10. ALL CONNECTORS SHALL COMPLY WITH ASTM A653 CLASS G-185. ii. FOR SMS, THE MINIMUM CENTER -TO -CENTER SPACING SHALL BE 3/4" AND MINIMUM CENTER -TO -EDGE SHALL BE 1/2" UNLESS NOTED OTHER WISE. 1�:7�1��1.��1.�7t5f11•h1i/S:� ASTM E 119 ASTM E 1300 CURRENT ASCE 7 CURRENT ALUMINUM DESIGN MANUAL -AA ASM35. AND SPEC. FOR ALUMINUM PART 1-A, & 1-B ASTM C94 ASTM C150 ASTM C33 ASTM C260 ASTM C494 ASTM A615 ASTM A185 FLORIDA BUILDING CODE 7TH EDITION (CHAPTERS 16, 20 & 23). THE FOLLOWING LIST OF ABBREVIATIONS IS NOT INTENDED TO REPRESENT ALL THOSE USED ON THESE DRAWINGS, BUT TO SUPPLEMENT THE MORE COMMON ABBREVIATIONS. 1. TYP --TYPICAL 2. SIM -- SIMILAR 3. UON -- UNLESS OTHERWISE NOTED 4_ CONT -- CONTINUOUS 5. VIF -- VERIFY IN FIELD i + _ L ALL SITE WORK SHALL BE PERFORMED BY A LICENSED CONTRACTOR IN ACCORDANCE WFTH APPLICABLE BUILDING CODES, LOCAL ORDINANCES, ETC. 2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND DETAILS. NOTIFYING ENGINEER OF ANY DISCREPANCIES BETWEEN DRAWINGS, FABRICATED ITEMS, OR ACTUAL FIELD CONDITIONS. 3. THESE DRAWINGS REPRESENT THE ACCEPTABILFI'Y OF THE 'SUNROOM' ROOM ADDITION ELEMENTS AS PROVIDED BY THE CONTRACTOR. 4. ALL DETAILS ON THESE DRAWINGS ARE, ENGINEERED BASED ON INFORMATION PROVIDED BY THE CONTRACTOR AND MANUFACTURER. 5. ANY DETAILS NOT SHOWN ARE TO BE ENGINEERED BY A LICENSED P.E. IN ACCORDANCE WITH STANDARD ENGINEERING PRACTICES. n. MISCELLANEOUS: ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME. IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPARATE 4TH WALL SUPPORT SYSTEM MUST BE ENGINEERED SO THAT NO ADDITIONAI. LOADING IS PLACED ON THE MANUFACTURED HOME. 2. IF ENCLOSURE CONTAINS A SWIMMING POOL OR SPA, THE ENCLOSURE SHALL COMPLY WITH RESIDENTIAL SWIMMING BARRIER REQUIREMENTS Of THE FSC 7TH EDITION R 4501.17 IN ITS ENTIRETY. 3. DOOR LOCATIONS MAY BE DETERMINED IN THE FIELD BY CONTRACTOR. 4. IF PAVERS ARE UNDER ALUMINUM MEMBERS THEY SHALL HAVE EPDXY ADHESIVE TO CONCRETE OR IF USING GROUT, ENSURE BONDING AGENT" IS USED FIRST AND ADHERED WITH MINIMUM 3000 PSI GROUT. SCREENING MATERIAL SHALL BE I8X14X0.013 OR EQUIVALENT DENSITY SCREEN MESH ONLY UNLESS NOTED ON DRAWINGS-2. DESIGN DATA: 1. ULTIMATE DESIGN WIND SPEED Vult, (3 SECOND GUST): NOMINAL DESIGN WIND SPEED Vasd: 2. RISK CATEGORY: 3. WIND EXPOSURE: 4. WIND LOADS: SCREEN ROOF: N/A SCREEN WALLS: 23 PSF SOLID ROOF (SCREEN WALL): 20 PSF 130 MPH 101 MPH I B 5. FACTOR APPLIED TO SCREEN WIND LOADS FOR 18X14X0.013 OR EQUIVALENT DENSITY SCREEN MESH: 0.88 6. FACTOR APPLIED 10 SCREEN WIND LOADS FOR ALLOWABLE STRESS DESIGN: 0.6 7. LIVE LOAD: 300 1b. VERTICAL DOWNLOAD ON PRIMARY SCREEN ENCLOSURE MEMBERS. 20G Ib, VERTICAL DOWNLOAD ON SCREEN ENCLOSURE PURLINS. 10 ;'SF VERTICAL DOWNLOAD ON SOLID ROOF. 8. EXISTING SLAB AND OR FOOTING (MIN. 4" CONCRETE SLAB) MEETS THE REQUIREMENTS TO RESIST THE UPLOADS FOR THE PROPOSED STRUCTURE. 9. SCREEN ROOF TYPE: N/A 10. SOLID ROOF TYPE: 3"X48"X0.024" ELITE EPS COMPOSITE PANEL ROOF IIb FOAM DENSITY, FLORIDA PRODUCT APPROVAL, FL 7561-RS OR EQUIV. a 1 • a Doi X N bIl 2 x 2:---------------------------------------2" x 2" x 0,044" 2 x 3:--------------------------------------2" x 3" x 0A50„ 2 x 4:--------------------------------------2" x 4" x 0,050" 2 x 5:------- .-------------------------------- 2" x 5" x 0.050" 3 x 3:---------------------------------------3" x 3" x 0.1.25" 1x2: 1x3: 1" x 2" x 0.040" 1" x 3" x 0.045" INDEX: S-1 GENERAL NOTES S-2 DRAWING S-3 DETAILS S-4 DETAILS 2 x 2 SMS:---------------------------2" x 2" x 0.045" 2 x 3 SMS: -------------------------2" x 3" x 0.072" v, 2 x 4 SMS:--------------------------------- 2" x 4" x 0.045„ 3 x 3 SMS:----------------------------- --- 3" x 3" x 0.090" Bffffffura _ v IF 2 x 4 SMB:--- - ------------ 2" x 4" x 0.044" x 0.100" 2 x 5 SMB:------------------- 2" x 5" x 0.050" x 0.118" 2 x 6 SMB:------------------- 2" x 6" x 0.050" x 0.120" 2 x 7 SMB:-------- -- - 2" x 7" x 0,057" x 0.120" 2 x 8 SMB: -- -- ---- 2" x 8" x 0.072" x 0.224" 2 x 9 SMB:- - - - - -- 2" x 9" x 0,072" x 0.224" 2 x 10 SMB:------------------ 2" x 10" x 0.092" x 0.374" TUBE SECTIONS 2 x 2:-------------------------------------2" x 2" x 0.090" 21 wu -- e 7 , V ENGINEER OF RECORD: David W. Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson P.E FLORIDA LICENSE: 38654 Myron Max Neal P.E. FLORIDA LICENSE: 86663 Joel Falardeau P.E. FLORIDA LICENSE: 70667 Erik Stuart P.E. FLORIDA LICENSE: 77605 FBC Plans $r Engineering Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 Ph#(813)788-5314 Fax# 1-(866)824-7894 E-mail-erb@fbcplans.com Website-www.fbcplans.com C.O.A.-#29054 DATE: 10/08/2021 DRAWN BY: ST REVISION: DATE: RO 1 RO 2 RO 3 RO 4 •# PROJECT tt ADDRESS: C' `S 3200 MOULDEN HOLLOWWi FEPHYRHILLS, FL 4, NOTES S-3 W/ 7 S. G. M11 11 Lc) In 0 (1) LB FOAM ljil !COMPOSITE 'PANEL ROOF MIN. i PER 1' SLOPE 0 toil X Nil S-3II ) 2x3'EDGE BM —24 0 44 —26 0" 2x3 ED3E BM Q0 X X X X X C14 CN N N 2x2(tvD) 1x2 5-0 1113 0 1�6 0" (ty P) GS-3) MIN I lij X III II KICKPLATE (TYP) T-1 x2 T 0 400 I I << N 0 0, C N PLo PR10F),i11.;1'1k�E1Rt'AL ENGINEER OF RECORD: David W. Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson P.E FLORIDA LICENSE: 38654 Myron Max Neal P.E. FLORIDA LICENSE: 86663 Joel Falardeau P.E. FLORIDA LICENSE: 70667 Erik Stuart P.E. FLORIDA LICENSE: 77605 FBC Plans & Engineering Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 Ph# (813)788-5314 Fax# 1-(866)824-7894 E-mail-erb@fbcplans.com Website-www.fbcp1ans.com C.O.A.429054 DATE: 10/08/2021 DRAWN BY: ST REVISION: DATE: RO 1 RO 2 RO 3 Job# 21 - 1008 - 112 PROJECT ADDRESS: CPEARS 3200 MOULDEN HOLLOW aM !:EPHYRHILLS, FL 33540 — UPRIGHTw� SECONDARY ANGLE MINA (4) #10 X 3/4" SMS 0.125" THICK (NOT ��e* sN 40 REQUIRED FOR 2X3 \ �4 ALUMINUM RISER PAN FASTENING SECONDARY MEMBER) ANGLE TO COLUMN (TY 0. EACH SIDE) Q #12 SMS W/ 1"0 NEO-WASHERS (4) #12 SMS W/ 3/4" 1 X 0I.11 5" ANGLE �� @ 8" O.C. USE SCREW LENGTH (B) - CONCRETE SCREW ( WASHERS PER 12" F ANEL (2) #10 X 3/4" SMS FASTENING 0 EQUAL TO COMPOSITE PANEL ANCHOR INTO SECONDARY COLUMN TO PRIMARY ANGLE �� S��� THICKNESS PLUS (1) [NCH) ANGLE(TYP EACH SIDE) TASEE BI E) O O (rYP EACH SIDE) �� ®� ,. SEE DETAIL C2 FOR OPTION #1 OPTION #2 O I" X 2" BASE MEMBER ��� e ALUMINUM RISER PANS ietarl� (4)#10 x 1' SMS RECEIVING CHANNEL ANCHOR SPA (1'YP EACH SIDE) PR� SEAL INTO SCREW OR ANGLE EA. SIDE (typ) I (MIN) (TYP)(SEE TABU) (1) - CONCRETE SCREW (SEE BOSSES (.0625" THICKNESS) d TABLE) ANCHOR INTO PRIMARY ENGINEER OF RECORD: ANGLE AND @ 1/4" 0 CONCRETE n — — — — — — — — — 3" (MIN) SCREW ANCHOR @ David W. Smith P.E. 24" O.C. BETWEEN COLUMNS FLORIDA LICENSE: 53608 i 2"X2' OR 2"X3" (2) #1Ox 3/4" SMS (2) - 3/8" MACHINE I OPTIONAL 1" X 2" FASTENED PURLIN OR GIRT (typ) EA. LEG) BOLTS WITH 3/4" 1 i TO COLUMN WITH (2) #10 X 2" (TOTAL 6 SCREWS R.C. (8) WASHERS THROUGH 1 SMS INTO SCREW BOSSES SCREWS ANGLE EA. POST AND EDGE BEAM i � AND FASTENED TO EDGE CONNECTION) � BEAM WITH (1) #10 X 1-1/2" i t SMS WITHIN 6" OF COLUMN CONTINUOUS EDGE BEAM AND @ 12" O.C. MAX rH POST PURLIN OR GIRT TO BEAM OR POST DETAIL NOTE: EDGE BEAM (SEE SHEET S-2 FOR SIZE) SHALL BE ORIENTED IN DIRECTION SHOWN. S-3 scALE:NEs Column Size 1/4"& 3/8" 0 Concrete Screw Anchor B Min. Spa 2x3-1/4" 0 0" 2x4-1/4" 1 3" 2x5-1/4" 1 3" 2x6-3/8" 1 4" 2x7-3/8" 1 5" 2x8-3/8" 2 3" 2x9-3/8" 2 4" 2x10-3/8" 2 4.5" NOTES: (TYP EACH SIDE) "B" Thomas L. Hanson P.E 1. NUMBER OF ANCHORS IS EACH SIDE INTO THE SECONDARY ANGLE AND DOES NOT INCLUDE THE ANCHOR INTO THE 1X2. FLORIDA LICENSE: 38654 2. MINIMUM EMBEDMENT OF ANCHORS INTO CONCRETE FOOTING SHALL BE 2-3/4" AT AT ALL UPRIGHT LOCATIONS, ALL SCREW /� MaxNeal Myron MNeal P.E. LENGTHS AT UPRIGHT CONNECTIONS SHALL BE OF SUFFICIENT FLORIDA LICENSE: 86663 LENGTH FOR REQUIRED EMBEDMENT INTO CONCRETE FOOTING WHEN A PAVER DECK IS PRESENT. 7 Joel Falardeau P.E. 3. CONCRETE SCREW ANCHOR DESIGNS ARE BASED ON THOSE LISTS",FLORIDA LICENSE: 70667 ON S-1, D. FASTENERS, OTHER BRAND & TYPE SHALL BE APPROVED BY ENGINEER. 7_ Erik Stuart P.E. 4.2X3W/1X2 CORNER POST SHALL REQUIRE SAME BASE FLORIDA LICENSE: 77605 CONNECTIONS AS 2X4 SHOWN IN TABLE. S. IF FOR AN IN -FILL, TOP OF COLUMN CONNECTION SIMILAR IF S ROOF PANEL TO EDGE BEAM CONNECTION DETAIL CONCRETE LINTEL. IF WOOD LINTEL SUBSTITUTE 1/4" 0 x 3" LAG FBC Plans & Engineering SCREW FOR 3/8"0 LOT FOR BOTH PRIMARY & SECONDARY ANGLES. Services, inc. �S-3 SCALE: NTS 6. 2X2X.045 DOOR JAMB MEMBER SHALL CONNECT SIMILAR TO 2X3 MEMBER. 6272 Abbott Station Dr. Unit 101 2" x 3" OR LARGER UPRIGHT TO CONCRETE W WO PAVER DETAILS Zephyrhills, FL 33542 S_3 SCALE: NTS Ph# (813)788-S314 Fax# 1-(866)824-7894 --- -- - - _ - - ---- ------ ----- - — E-mail-erb@fbcplans.com Website-www.fbcplans.com C.O.A.-#29054 I HINGE LOCATION i j DATE: 10 08 2021 BREAK FORM HEADER OR DRAWN BY: ST RECEIVING CHANNEL 2" x 2" EXTRUSION 2" x 2" EXTRUSION 410 SMS AT EACH RISER REVISION: DATE: 'OR PAN OR #10 SMS @ EXISTING MASONRY RO 1 8" O.C. FOR COMPOSITE PANEL WALL GROUTED HINGE LOCATION DOOR SOLID RO 2 d OLID ROOF 0 @CONNECTION RO 3 ®® R04 ® 1/4"0 X 2-1/2" 10�# 2�_�d�g_21Z d MASONRY SCREW 3" FROM G END&@24"O.C. 2 x -__-END BE PROJECT ADDRESS: HINGE LOCATION d (SEE SHEET S-2FOR SIZE) SPEARS #10 SMS @ 8" O.C. 2" x 2 " x 1/8" x BEAM DEPTH" 3200 MOULDEN HOLLOW DR FOR COMPOSITE PANEL RECEIVING CHANNEL ZEPHYRHILLS, FL 33540 n�oT�s- (4) #10 SCREWS PER 12" W/ (1) 1/4" x 3" CONCRETE 1"X2" OPEN BACK 1. HINGES SHALL BE ATTACHED TO STRUCTURE W/ (4) #10 x 5/8" SMS MINIMUM, WIDTH CONNECTING ANCHOR INTO WALL & 2. DOOR SHALL BE ATTACHED TO ENCLOSURE w/(2) HINGES MINIMUM, PAN TO HEADER (BOTTOM OF PAN) (4) #10 x 3/4" SMS EACH SIDE INTO BEAM h� CONTRACTOR: 3. HINGES SHALL BE ATTACHED TO DOOR WITH (3)#10 x 5/8" SMS. FASTEN A 1" x 2" x 0.044" TO UPRIGHT W/#12 x 1' SMS @ 12" O.C. AND WITHIN 3" FROM NOTE: WHEN ATTACHING TO WOOD STRUCTURES, WOOD LAG SCREW PATRIOT SCREENS, INC. END OF THE UPRIGHT. 1/4"13" MASONRY ANCHORS 24" O.C. ANCHOR DESIGNS SHALL BE OF IDENTICAL SIZE AND EMBEDMENT AS THAT (2) ROWS STAGGERED CONNECTING OF MASONRY ANCHOR SCREWS. HEADER OR CHANNEL TO HOST. F S S2 END BEAM TO HOST STRUCTURE DETAIL TYPICAL SCREEN DOOR CONNECTION DETAIL ROOF PANEL TO WALL CONNECTION DETAILS S-3 SCALE: NTs S-3 sCALE.NTS S-3 SCALE: NTS I DETAILS I