HomeMy WebLinkAbout21-3305City of Zephyrhills
5335 Eighth Street
Zephyrhills, FL 33542
BNR-003305-2021
Phone: (813) 780-0020
Fax: (813) 780-0021
Issue Date: 01/20/2022
Permit Type: Building New (Residential
12"',
7681 Sail Clover Ln
Name: D R HORTON Permit Type: Building New (Residential) Contractor: DR HORTON
Class of Work: SFR Construct
Address: 12602 Telecom Dr Building Valuation: $110,000.00
TAMPA, FL 33637 Electrical Valuation: $7,000.00
L
Phone: (813) 549-1968 Mechanical Valuation: $6,000.00
Plumbing Valuation: $8,000.00
Total Valuation: $131,000.00
Total Fees: $18,438.25
e6_
Amount Paid: $18,438.25 J,
Date Paid: 1/20/2022 12:19:20PM
g
10 0
CQNSTRUCT SINGLE FAMILY 2,777 SQ FT ZL
Q VNIK,
Building Permit Fee $590.00 Mechanical Plan Review Fee $35.00
Address Fee $30.00 Irrigation 3/4 Meter (Cale) $473.78
SIF 1 percent Fee $8128 Plumbing Permit Fee $80.00
Public Safety Impact Fee -Police $254.00 Electrical Plan Review Fee $37.50
Park Impact Fee - Single Family/Townhome $769.56 Electrical Permit Fee $75.00
Public Safety Impact Fee -Admin $26.35 Driveway Fee $45.00
Building Plan Review Fee $295.00 Transportation Impact Fee - City $36,32
School Impact Fee - Single Family $8,328.00 Water Connection Residential Fee $1,010.00
Transportation Impact Fee $3,595.68 Mechanical Permit Fee $70.00
Sewer Connection Residential Fee $2,090.00 Plumbing Plan Review Fee $40.00
.3/4 Water Meter Fee (Cale) $473.78
REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection, whichever is greater, for each subsequent reinspection.
Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing, consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
- - --------
CONTRACTOR SIGNATURE PE IT OFFICE* I
V
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
BILLING CONTACT
Da GUDE
DR HORTON
04`1 41M
11F_,XTAIVM2WC !k
INVOICE NUMBER=
INVOICE DATE
INVOICE DUE DATE
INVOICE STATUS
INVOICE DESCRIPTION
INV-00005857
01/08/2022
02/07/2022
ill 101 ilk I
REFERENCE NUMBER
FEE NAME
TOTAL
BNR-003305-2021
3/4 Water Meter Fee {Cale)
$473.78
Address Fee
$30.00
Building Permit Fee
$590.00
Building Plan Review Fee
$295.00
Driveway Fee
$45.00
Electrical Permit Fee
$75.00
Electrical Plan Review Fee
$37.50
Irrigation 3/4 Meter {Cale)
$473.78
Mechanical Permit Fee
$70.00
Mechanical Plan Review Fee
$35.00
Park Impact Fee - Single Family/Townhome
$769.56
Plumbing Permit Fee
$80.00
Plumbing Plan Review Fee
$40.00
Public Safety Impact Fee -Admin
$26.35
Public Safety Impact Fee -Police
$254.00
School Impact Fee - Single Family
$8,328.00
Sewer Connection Residential Fee
$2,090.00
SIF 1 percent Fee
$83.28
Transportation Impact Fee
$3,595.68
Transportation Impact Fee - City
$36.32
Water Connection Residential Fee
$1'010.00
7681 Sail Clover Ln Zephyrhills, FL 33540 SUB TOTAL
$18,438.251
REMITTANCE INFORMATION
City of Zephyrhills
5335 8th Street
Zephyrhills, FL 33542
TOTAL 1 $18,438.25
January 10, 2022 5335 8th Street, Zephyrhills, FL 33542 Page 1 of 1
PASCO COUNTY, FLORIDA
Permit No. 33
Date Permltte
Builder Name/Owner Name Control
County Parcel No. �? Do Q)DIv:
k
Address/Location Lki
Classificationfrype of Use �S 1),)a te
TRANSPORTATION IMPACT FEE Rate: So Ft Unit:
Exempt * C] Ves E] No How Determined
ImpactFeeAmount Zone No. TAZ:
SCHOOL IMPACT FEE
Account (056) Single -Family Detached House Amount $ e/ V11j 2-t
(067) Mobile Home
(058) Other Residential
(123) Collection Fee
Exempt E] Yes [3 No How Determined
PARKS AND RECREATION FEE -
Land Account Land Credit Land Total
Recreation Account Recreation Credit Recreation Total
Zone TOTAL AMOUNT $ �7
Exempt El Yes E] No How Determined
LIBRARY FEE
Land Account Land Credit Land Total
Facility Account Facility Credit Facility Total
Exempt []Yes []No How Determined Total Amount
WESOIRCEW ERU
TOTAL AMOUNT
zm«: is�
Chocked By
, 00" AF I " 0j, ilsil�ltl.1.1214.114'1'1 I A(A01 't9-4,; #0 - �
11114 11-OPM-1 M_ 18i6"
ITI—iomm"414— 111111111 1 11
RECEIPT NO. -DATE BY
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
Immoyes@dmorton.com
Date Received Phone Contact for Permitting I �
Owner's Name DR Ho7n Inc Owner Phone Number 813-549-1968
Owner's Address 1 12602 Telecom Drive; Tampa, FL 33637 Owner Phone Number
Fee Simple Titleholder Name Owner Phone Number
Fee Simple Titleholder Address I I
SUBDIVISION
I Abbott Park I
WORK PROPOSED
NEW CONSTRF7 ADD/ALT
SIGN
DEMOLISH
e
INSTALL REPAIR
PROPOSED USE
F,7/ SFR COMM
OTHER
TYPE OF CONSTRUCTION
BLOCK FRAME
STEEL
DESCRIPTION OF WORK
New Single Family Residence
Beds,
Baths, Story Hom
BUILDING SIZE
-1 SQ FOOTAGE
HEIGHT
=BUILDING
Lo VALUATION OF TOTAL CONSTRUCTION
=ELECTRICAL
I$ r) I AMP SERVICE
PROGRESS
ENERGY W.R.E.C.
®PLUMBING
51
7,-7 -�)
'Al
=MECHANICAL
=6C
VALUATION OF MECHANICAL INSTALLATION
4�
=GAS ROOFING SPECIALTY 0 OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO
BUILDER <T COMPANY [DR Horton, Inc
SIGNATURE REGISTERED Y/N FEE CURREN
2602 Telecom Drive; Tampa, FL 3363'
Address License #
ELECTRICIAN COMPANY
[Strada Electric
SIGNATURE V REGISTERED Y/N FEE CURREN [=N
a &�—
Address 3400 St Johns Pkw&'y; Sanford, FL 32771 License # 5
PLUMBER COMPANY Northwest Plumbing
SIGNATURE REGISTERED Y/N FEE CURREN Y/N
Address PWNY, St 1000; Mapleton, GA 30126 License #I CFC1427137
MECHANICAL COMPANY [Progressive Air Systems
SIGNATURE REGISTERED =N FEE--,CURREN
Address 7130 Meighan Ct; New Port Richey, FL 34652 License #I CAC033669
OTHER COMPANY Brad McDonald Roofing
SIGNATURE REGISTERED YIN FEE CURREN Y/N
Address 7143 SR 54; New art Richey, FL 34653 1 License # ICC1325833
2911111111111 will IIIIIIIII IIIIIII a as I'll 1.91112 sills will 111,32111111 all 111114
RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction,
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 durripster; Site Work Permit for subdivisions/large projects
COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction.
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance
SIGN PERMIT Attach (2) sets of Engineered Plans.
****PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner & Contractor sign back of application, notarized
If over $2500, a Notice of Commencement is required. (A/C upgrades over $7500)
— Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage)
Driveways -Not over Counter if on public roadways..needs ROW
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive
than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they
may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and
contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements
may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009.
Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this
application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is
not entitled to permitting privileges in Pasco County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or
expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that
such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery
Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final
power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior
to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): if valuation of work is $2,500.00 or more, I certify that I, the applicant,
have been provided with a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of
Agriculture and Consumer Affairs. if the applicant is someone other than the 'owner", I certify that I have obtained a copy of the above described
document and promise in good faith to deliver it to the "owner" prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with
all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as
indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all
laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I
understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I
must take to be in compliance. Such agencies include but are not limited to:
- Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
- Southwest Florida Water Management District -Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers -Seawalls, Docks, Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency -Asbestos abatement.
- Federal Aviation Authority -Runways.
I understand that the following restrictions apply to the use of fill:
- Use of fill is not allowed in Flood Zone W" unless expressly permitted.
- if the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to
commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or
other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as
authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from
thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work
authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a
period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to
exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered
abandoned.
r. t .. .. +. `.. r. .. i. .. _40immilardmoll 11210 1 9111LOX0011w 11F.Allil, 11112110rai"M
...
FLORIDA,IURAT (F.S. 117,03)
11
OWNER OR AGENT CONTRACTOR
Sub crib d and swo t (or firmed) before m this Subscribed and sworn to (or affirmed) before me this
i by Michelle Meyes by
® o i are personally known tome or has/have produced Who is/are personally known to me or has/have produced
as identification. as identification.
j ( Z+ `C/EC J _Notary Public
+-� Commission No. i `Y - ✓ 2+ bc-
Name of Notary typed, printed or stamped
p��ir
HEATHER MUNDT
og"g.
a ......
...« `'
Commission # GG 945499
o<
Expires May 3, 2024
'lFai:t�o�`
Band�lTl�u6udpct
Commission N
Name of Notary typed, printed or stamped
otary Public
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
ite Received
MMoyes@drhorton.com
Phone Contact for Permitting
29
Avner's Name DR Norton Inc
Owner Phone Number 813-549-19(38
Nner's Address 1 12602 Telecom Drive; Tampa, FL 33637
Owner Phone Number
:e Simple Titleholder Name I Same
Owner Phone Number
:e Simple Titleholder Address
I
)B ADDRESS
LOT #
UBDIVISION Abbott Park (Zephyr Lakes) PARCEL ID#
(OBTAINED FROM PROPERTY TAX NOTICE)
`ORK PROPOSED NEW CONSTRF7 ADDIALT
SIGN DEMOLISH
INSTALL REPAIR
ROPOSED USE SFR COMM
l_ ! OTHER
APE OF CONSTRUCTION BLOCK FRAME
t_ _ J STEEL
ESCRIPTION OF WORK
UILDING SIZE I SQ FOOTAGE =
HEIGHT
N/A BUILDING
VALUATION OF TOTAL CONSTRUCTION
$NIA
NIA ELECTRICAL $ N/A AMP SERVICE PROGRESS ENERGY W.R.E.C.
NIA PLUMBING $ N/A
NIA MECHANICAL EWA
VALUATION OF MECHANICAL INSTALLATION
N/A GAS ROOFING SPECIALTY = OTHER
WISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO
UILDER COMPANY
IGNATURE REGISTERED Y/ N FEE CURREN Y I N
Address License # �-
IGNATURELECTRICIAN
REGISTERED Y/ N FEE CURREN Y/ N
Address ®� License #
LUMBER COMPANY Lawn Medic Landscape & Irrigation
IGNATURE REGISTERED YIN FEE CURREN Y / N
Address 4827 Beauchamp Rd; Plant City, FL 33563 License# I SCC131152084
IECHANICAL COMPANY
IGNATURE REGISTERED Y / N FEE CURREN Y =N7
4
Address _ License #
ITHER
COMPANY
IGNATURE REGISTERED Y / N FEE CURREN Y / N
Address e License# �'^
12.2 1.4
tESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction, ,
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects
:OMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction.
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance
;IGN PERMIT Attach (2) sets of Engineered Plans. l
****PROPERTY SURVEY required for all NEW construction.
,k
Ilrections:
Fill out application completely.
Owner & Contractor sign back of application, notarized
If over $2500, a Notice of Commencement is required. (A/C upgrades over $7500)
Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same
)VER THE COUNTER PERMITTING (copy of contract required)
teroofs if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage)
Driveways -Not over Counter if on public roadways..needs ROW
813-780-0020 City of ZephyrhiUsPermit Application Fax-813-780-0021
Building Department
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive
than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they
may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and
contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements
may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009
Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" ofthis
application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is
not entitled to permitting privileges in Pasco County.
TRANSPORTATION IMPACTILITILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned Understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or
expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that
such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery
Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final
power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior
to permit issuance in accordance with applicable Pasco County ordinances,
CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant,
have been provided with a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of
Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described
document and promise in good faith to deliver it to the "owner"prior to commencement.
CONTRACTOR'SIOWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with
all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as
indicated, I certify that no work or installation has commenced prior to issuance of a permit and that all work Will be performed to meet standards of all
laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I
understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I
must take to be in compliance, Such agencies include but are not limited to:
Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
� Southwest Florida VVotor Management Diotrict4Na||a, Cypress Boyheadu, Wetland Areoa, Altering
Watercourses.
- Army Corps of Engineers -Seawalls, Docks, Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit4Wa||e, Wastewater Treatment,
Septic Tanks.
- U8Environmental Protection Agency -Asbestos abatement.
- Federal Aviation Authority-Runwmya,
| understand that the following restrictions apply tvthe use offill:
- Use offill ienot allowed inFlood Zone Wrunless expressly permitted.
- If the fill material is to be used in Flood Zone "A^, it is understood that o drainage plan addressing a
''compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A^ in connection with a permitted building using stem wm||
construction, I Certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any anae..| certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent propertiee, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated byfill, snengineered drainage plan isrequired.
|f|amthe AGENT FOR THE OWNER, | promise ingood faith minform the owner ufthe permitting conditions set forth inthis affiuovitprior tu
commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or
other installations not specifically included in the application. x permit issued nhoK be construed to be a |inonoo to proceed with the work and not as
authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from
thereafter requiring a correction of errors in plans, construction or violations of anyg .Everypennitixuuogxhanuroomuinvn|igun|aonthe*mrk
authorized by such permiticommenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned fora
period of six (6) months after the time the work in unmmonoau. An extension may be requaoted, in writing, from the au|mmg Official fora period not to
exceed ninety (o0)days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered
abandoned.
lei to] 11i"
FLORIDA JunxTVF.s. 11
OWNER OR AGE" CONTRACTOR
Sub crib and sworn t (c( affirmed) before rn�t �i Subscribed and sworn to (or affirmed) before me this
Wjo'islire p�rsonally known to me or has/have produced Who is/are personally known to me or has/have produced
as identification, as identification.
Corn mission No. a
Name of Notary typed, printed or stamped
KF-ATHERNUND
:omm�Wun#GG�5�9
ExplireoMay 3,3020
'v^pp/r
mmwmmmam0mw�nam��
Commission No
Name of Notary typed, printed or stamped
I , RKE, shall be a minimum of 8" above the road elevation and an engineered site plan,
2. Lots shall be graded to comply with R401.3 of the F.B.C,
3, Cornpaction test required if 24" or more of fill dirt is brought in at any one place.
4, Tie in survey required before pouring concrete,
5. Driveways require a R,O.W. use permit. All 4 sides of driveway thru the sidewalk shall have
expansion material.
6. All setbacks shall be met.
7, All property markers shall be uncovered and marked at time of first inspection,
8, All A.D.A. requirements shall be met.
9o electric, plumbing, mechanical, or frarning shall be covered without an inspection and
approval first,
I O, All Garages shall comply with section R302,6 of the R B,C. (Fire Separation),
I 1. Appliances shall not be installed in a location where subject to mechanical darnage unless
protected by approved barriers. M303A of the F.B,C
12. NVater heaters shall comply with section P607,3 of the RB.C.
13, Foundation supports for A/C units shall Inc, raised at least 3" above finished grade. M 1308.1
14. Retum air in all bedrooms, F.B.C. M 1 620A
15, Smoke detectors are to be installed in accordance with R313. I of the B.C.
16, All glazing requirements are to be in accordance with R308A of the F,B,C.
17. All mearis of egress are to be in accordance vvith R3 I I of the F.B.C.
18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702,4,2 F,B.C,
19. Cornbi nation- type AM breakers are required at all locations requiring an ARIA type breaker.
20. Carbon monoxide alarms will be required in new construction that uses fossil -burning heating
or appliances or an attached garage. 'rhey shall be installed in accordance with the F.B,C.
21, A] plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all
underground plumbing and electric,
22, All 2016 N.E,C. Codes will be ent-orced.
23. Tamper- Resistant Receptacles in accordance with 406,11 of the 2016 KE.0
24. In accordance with the Land Development Code, lots shall be sodded before filial at least 10
feet around the stmaure.
25, R403,53Hot water pipe insulation
Insulation for hot water pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the
following:
Piping,/, inch (19,1 mm) and larger in nominal diameter.
Piping serving more than one dwelling unit,
Piping located outside the conditioned space,
Piping from the water heater to a distribution manifold,
Piping located under a floor slab,
Buried in piping.
Supply and return piping in recirculation systems other than demand recirculation systems,
25. Blower door test shall be provided before C.O.
26 all Urnes.
27. itii ent nitbe re maL
2&
F.F.E.-Finished Floor Elevation
F.B.C- Florida Building Code 6th Edition
R.O.W.-Right of Way
A.D.A.- Americans with Disabilities Act N.E.C.- National Electric Code (2016)
PLOT PLAN
DESCRIPTIDN:(AS FURNISHED)
LOT 40, BLOCK 7, ZEPHYR LAKES SUBDIVISION PHASE 4B
AS RECORDED IN PLAT BOOK 85, PAGE(S) 126-128, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA.
ON LOT CALCULATIONS
LOT
= 5,653
SQ.
FT.
LIVING AREA
= 907
SQ.
FT.
GARAGE
= 453
SQ.
FT.
ENTRY
= 64
SQ.
FT.
LANAI
= 0
SQ,
FT.
PATIO
= 80
SQ.
FT.
DRIVEWAY
= 409
SQ,
FT.
A/C PAD
= 12
SQ.
FT.
WALKWAY
= 65
SQ.
FT.
IMPERVIOUS
= 35%
= 1990
SQ.
FT.
SOD
= 3,663
SQ.
FT.
OFF LOT CALCULATIONS
RIGHT OF WAY
= 493
SQ.
FT.
DRIVE APRON
= 152
SQ.
FT.
PUBLIC S/W
= 195
SQ.
FT.
SOD
= 146
SQ.
FT.
TOTALS
AREA
= 6,146
SQ.
FT.
DRIVEWAY
= 561
SQ.
FT.
SIDEWALK
= 260
SQ,
FT.
SOD
= 3,809
SO,
FT.
.. WO i 0
W OO
Curve Table
Curve N
Length
Radius
Delta
I Chord Bearing
Chord
C1
39.19'
975.00'
2"18'11"
S02'19'55"E
39.19'
C2
44.62'
1110.00'
2'18'11"
NO2'26'22"W
44.61'
C3
290.45'
950.00'
17'31'03"
SOB'36'00"E
289.32'
C4
60,39'
950.00'
3'38'32"
S01'39'45"E
60.38'
C5
230.06'
950,00'
13'52'30"
SI0'25'16"E
229.49'
LOT 39
BLOCK 7
g`G
-.--(NON-RADIAL) (RADIAL)-"^-
�0'
(REFERENCE BEARING)
N88'49'11 "E 134.95'
� � N
. _.._
(
59.5' 8.0'
wo>
I
n PROPOSED 2' 5 .3'
S
P'" 3EE6 ELTON G
oN
>w
mn
ELEVATION=98.10'34.T2
a 0 FINISHED Zo
gµ
%i
Q - 50.00'
m o I I.
D
50.0'
r
._
W 134.86'
S86.30'59' W
sy
--.-{NON-RADIAL) (RADIAL)
's
LOT 41
LOT
I
BLOCK 7
BUILDING SETBACKS
FRONT: 20'
GARAGE: 25'
REAR: 15'
SIDE: 5'
SIDE STREET: 15'
NOTES:
1. PROPOSED ELEVATIONS SHOWN HEREON ARE
BASED ON THE APPROVED ENGINEERING PLANS
PREPARED BY HAMILTON ENGINEERING &
SURVEYING INC.
2. ELEVATIONS ARE BASED ON NAVD 1988
DATUM.
THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES
ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF
THE PROPOSED STRUCTURE, THE CONTRACTOR AND/OR
OWNER ARE REQUIRED TO VERIFY ALL SETBACKS, BUILDING
DIMENSIONS, AND LAYOUT SHOWN HEREON PRIOR TO ANY
CONSTRUCTION.
THIS IS NOT A SURVEY
THIS IS A PLOT PLAN ONLY
FLOOD NOTE: I HAVE EXAMINED THE F.I.R.M. MAP NO,
12101CO293F, DATED 09/26/2014, AND FOUND THE SUBJECT PROPERT,.
APPEARS TO LIE IN ZONE "X AREAS DETERMINED TO BE SPECIAL
FLOOD HAZARD AREAS SUBJECT TO INUNDATION BY THE 1% ANNUAL
CHANCE FLOOD EVENT.THE SURVEYOR MAKES NO GUARANTEES AS TO
THE ABOVE INFORMATION. PLEASE CONTACT THE LOCAL F.E.M.A, AGENT
FOR VERIFICATION.
BEARING BASIS:
BEARINGS SHOWN HEREON ARE BASED ON THE NORTHERLY LINE OF
LOT 40 BLOCK 7 BEING NBB'49'11"E. PER PLAT.
(FIELD DATE:)
SCALE: i" = 30 FEET
APPROVED BY: JB
JOB NO. 210733 LOT 40, BLOCK 7
DRAWN BY: DSB
a
0
z
ill =30,
GRAPHIC SCALE
0 15 30
z O
o y PC
' z
m0
Gm
6z
Qs a 1
I >I
I � 1
I m
I
J� 25.5't,
j I
� 250i
u - -
S86'30'59"W A�
^m 25.OV ) =Z
1 ➢m
LEGEND:
— —
BUILDING SETBACK LINE
— -
CENTERLINE
— - -
RIGHT OF WAY LINE
PROPOSED ELEVATION
PROPOSED DRAINAGE FLOW
CONCRETE
A/C
AIR CONDITIONER
S/W
SIDEWALK
0
g Irfi Nr
i " MAPPING,
yy
A11XVISIOWN Atdf,#I ANY. e1�lAi t [Ni'i.:
PCP
0'
o �
m A
r
0
>00
m�A
—1
c) x
= IT
0 D Z
11T
D
PI POINT OF INTERSECTION
PC POINT OF CURVATURE
PT POINT OF TANGENCY
RP RADIUS POINT
PRO POINT OF REVERSE CURVATURE
PCP PERMANENT CONTROL POINT
TYP TYPICAL
CS CONCRETE SLAB
(P) PER PLAT
(C) CALCULATED
PB PLAT BOOK
PGS PAGES
SQ, FT, SQUARE FEET
F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY
F.I.R.M. FLOOD INSURANCE RATE MAP
NAVD NORTH AMERICAN VERTICAL DATUM
D&UE DRAINAGE & UTILITY EASEMENT
DE DRAINAGE EASEMENT
UE UTILITY EASEMENT (PUBLIC)
1. THE SURVEYOR HAS NOT ABSTRACTED THE
LAND SHOWN HEREON FOR EASEMENTS, RIGHT
OF WAY, RESTRICTIONS OF RECORD WHICH
MAY AFFECT THE TITLE OR USE OF THE LAND.
2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN
LOCATED EXCEPT AS SHOWN.
3. NOT VALID WITHOUT THE AUTHENTIC
ELECTRONIC SIGNATURE AND THE AUTHENTIC
ELECTRONIC SEAL OF A FLORIDA LICENSED
SURVEYOR AND MAPPER.
Digitally signed by James Belem-
DN c—US, st—Florida, f=Odando,
o=Americ- Surveying & Mapping,
u=Profess anal land Surveyor,
3" t' em1 Bi n
n 7boteman@asmmrporate<omFOR
Date: 2021..09.22130025 0400 THE
Adobe Acrobat version: 11.0.23 FIRM
JAMES W. BOLEMAN PSM# 6485 DATE