HomeMy WebLinkAbout21-3339RNR-003339-2021 Issue Date: 01/26/2022 71ermit TvDe: Buildina New (Residential) _0 648 Sail Clover Ln 35 25 21 0180 01300 0090 Wiv Name: D R HORTON Permit Type: Building New (Residential) Contractor: DR HORTON Class of Work: SFR Construct Address: 12602 Telecom Dr Building Valuation: $118,000.00 TAMPA, FL 33637 Electrical Valuation: $7,500.00 Phone: (813) 196-8 Mechanical Valuation: $6,500.00 Plumbing Valuation: $8,500.00 Total Valuation: $140,500.00 Total Fees: $18,509.50 Amount Paid: $18,509.50 Date Paid: 1/26/2022 2:09:55PM CONSTRUCT SINGLE FAMILY 3153 SO FT ZL 111, 1 Milk M1111711121011 221 �j­ .2111 Mechanical Plan Review Fee $36.25 Park Impact Fee - Single Family/Townhome $769.56 Mechanical Permit Fee $72.50 Building Plan Review Fee $315.00 3/4 Water Meter Fee (Cale) $473.78 Electrical Plan Review Fee $38.75 Public Safety Impact Fee -Admin $26.35 Plumbing Permit Fee $82.50 Irrigation 3/4 Meter (Cale) $473.78 Transportation Impact Fee $3,595.68 School Impact Fee - Single Family $8,328.00 Building Permit Fee $630.00 Electrical Permit Fee $77.50 Water Connection Residential Fee $1,010.00 Address Fee $30.00 Public Safety Impact Fee -Police $254.00 Transportation Impact Fee - City $36.32 Plumbing Plan Review Fee $41.25 SIF 1 percent Fee $83.28 Driveway Fee $45.00 Sewer Connection Residential Fee $2,090.00 ism 01214 ouce: In may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. z-NO OCCUPANCY BEFORE C.O. CO-NTRACTOR'TIGNATURE PE IT OFFICEU YM PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION PASCO COUNTY� FLORIDA Permit No. Date Permitted Builder Name/Owner Name Control # County Parcel No. 2-5 1,C) Oe)k) aVSubDIv: Address/Location ClassificationfType of Use TRANSPORTATION 1 PAST FEE Rate: Sqft Unit: Exempt' E] Yes Ej No How Determined Impact Fee Amount 3 6,32— zone No. TAZ: SCHOOL IMPACT FEE Account (066) Single -Family Detached House Amount $ (057) Mobile Home (056) Other Residential 123) Collection Fee Exempt dyes 0 No How Determined Land Account Land Credit Land Total Recreation Account - Recreation Credit - Recreation Total Zone TOTAL AMOUNT _J_Z&Y, Exempt E] Yes E] No How Determined LIBRARY FEE Land Accounf Land Credit Land Total Facility Account - Facility Credit Facility Total Exempt [) Yes E] No How Determined -Total Amount ERU TOTAL AMOUNT Prepared By Chocked By NO CERTIFICATE OF OCCUPANCY WILL Be ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BSEN. PAID AND RECEIPTED FOR'BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY 44 U fTtl i t 'jJTgj0 1111MP41 "n buildina permit owner Wn0lice'Of We as s-ossmont and the o0nditions 6f payment for same, DATE _RECEIVED �SY RECEIPT NO. - DATE BY 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Receivedt. MMoyes@drhorton.com Phone Contact for Permitting a a 9 It a 9 it a ILK 1-M-2-2-s-M-i 19111 5-9-1a a. -Rat 4 Its& %__&Jk_ Owner's Name DR Horton Inc Owner Phone Number 813-549-1968 Owner's Address 1 12602 Telecom Drive; Tampa, FL 33637 Owner Phone Number Fee Simple Titleholder Name ISame Owner Phone Number Fee Simple Titleholder Address I JOB ADDRESS 13t) S, S,, r\ q'\-( "'kLOT # SUBDIVISION Abbott Park PARCELID#1 D,,p _2-!Sl -2, 1 S C) CUI i GO (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR F7 ADD/ALT SIGN DEMOLISH INSTALL REPAIR PROPOSED USE SFR COMM OTHER TYPE OF CONSTRUCTION BLOCK FRAME STEEL '2 DESCRIPTION OF WORK New Single Family Residence Beds, Bath S, Story Ham� BUILDING SIZE I I SQ FOOTAGE= HEIGHT �kv. ]LJLiLkkW_ kk kW.W.V. kw. k Wk k VIE K]EXIEx" =BUILDING VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ AMP SERVICE PROGRESS ENERGY W.R.E.C. =PLUMBING =MECHANICAL VALUATION OF MECHANICAL INSTALLATION =GAS ROOFING SPECIALTY OTHER FINISHED FLOOR ELEVATIONS E FLOOD ZONE AREA =YES NO BUILDER COMPANY DR Horton, Inc SIGNATURE REGISTERED Y/N FEE CURREN L11 N__] Address 12602 Telecom Drive; Tampa, FL 33637 License# I CBC039062 ELECTRICIAN COMPANY Strad@ Electric SIGNATURE REGISTERED L_y �N FEE CURREN L_YLN__� Address 3400 St Johns Pkwo'y; Sanford, FL 32771 License # FEC13003715 PLUMBER COMPANY Northwest Plumbing SIGNATURE s REGISTERED Ey= FEE CURREN Address 6310 Mabelton PVNY, St 1000; Mableton, GA 30126 License # CFC1427137 MECHANICAL COMPANY Progressive Air Systems SIGNATURE REGISTERED FEECU.RR,EN 7130 Meighan Ct; New Port Richey, FL 34652 Address License # tAt033669 OTHER COMPANY Brad McDonald Roofing SIGNATURE REGISTERED N FEE CURREN Y/N Address 7143 SIR 54; New ort Richey, FL 34653 License# ICC1325833 I 1111111111 112111111IS4114 1111111111113 1111221114 via's RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans wl Silt Fence installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Paje; (1) set of Energy Forms. R-O-W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans wl Silt Fence installed, Sanitary Facilities & 1 diumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely, Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (A/C upgrades over $7500) Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences (Plot/SurveylFootage) Driveways -Not over Counter if on public roadways..needs ROW 813-780-0020 City ofZephvrhU|oPermit Application ra«-813-780-0021 Building Department NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may uo restrictions" which may be more restrictive than County regulations.The assumes responsibility for compliance applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: Ifthe owner has hired ocontractor orcontractors toundertake work, they may be required to be licensed in accordance with state and local regulations, If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised tocontact the Pasco County Building Inspection Division —Licensing Section at72r'9*7-oonm. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s> sign portions mrthe "contractor Block" mtmv application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled topermitting privileges inPasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, numay bedue, will uaidentified atthe time vrpermitting. uis further understood that Transportation Impact Fees and Resource Recovery Fees must uapaid prior to receiving "certificate oroccupancy" ornna}pvwern:|eaue.|fthepnojectgoeonotinvoiv0000rtmuuucnfuooupaooynrfino| power release, the fees must be paid prior to permit issuance, Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior topermit issuance maccordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner', I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner' prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development, Application is hereby made to obtain a permit to do work and installation as indicated, I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction, I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management Dietrict4Ve||a, Cypress Bayheads, VVbt|ond Areaa, Altering Watercourses. - Army Corps of Engineers -Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit4Ne||a, Wastewater Treatment, Septic Tanks. - U3Environmental Protection Agency -Asbestos abatement. - Federal Aviation Authority-Runvveya, | understand that the following restrictions apply mthe use offill: ' Use offill ionot allowed inFlood Zone Wrunless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing e "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed bythe State ofFlorida. - If the fill material is to be used in Flood Zone "4^ in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, | certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent propertiee, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots |eaa than one (1) acre which are elevated byfill, anengineered drainage plan isrequired. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth inthis affiumwtprior to commencing construction. | understand that aseparate permit may ue required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license toproceed with the work and not ax authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period ufsix (e) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT Subscribed and sworn to(or affirmed) before methis Whd is/are personally known to me or has/have produced Who is/are personally known to me or has1have produced as identification. as identification. Notary Public Commission No. 5,q_541D'� Name of Notary typed, printed or stamped M��R��� ` Commission #GO 945409 Expires May &2024 Commission Name of Notary typed, printed or stamped otary Public Plan Review Comments I , FTE shall be a rninimuni of 8" above the road elevation and an engineered site plant, 2, Lots shall be graded to coniply with R401 .3 oft e F,B,C. 3, Cornpaction test required if 24" or rnore offill dirt. is brouight in at any orie plaice. 4Fie in survey required before pouring concrete, 5, Driveways require as R,,O,W, use pernift, All 4 sides of driveway thru the sidewalk shall have expansion material. 6, All sad-mcks shall be inet, 7, All propertyniarkers shall be uncovered and marked at time of thirst inspection, 8All A,D.A. requirements shalt be inet, 9, No electric, plumbing, mechanical, or trarning shall be covered without air inspection and approval first, 10, All Garages shall comply with section R302,6 of the F.B.C, (Fire Separation), 11, Appliances shall not be installed in a location where sutject to mechanical damage unless protected by approved barriers,, J\4303A of the F,B,C 12 \\Viter heaters shall comply with section P6073 of the F,B,C, 13, Foundation supports for A/C units shall be raised at least 3" above finished , aide, M 1 308A 14. Retum air in all bedrooins. RB.C, M 1 620A 15, Sinoke derectors are to be installed in accordance with R313. I of the f,,,B,C, W All glazing requirelTrents are to be in accordance with R308A of the F,B,(.- . 17, All nreans of egress are to be in accordance with R311 of the F,B,C, 18, "Green gypsttm board" shall riot be used as a backer in showers or tubs, R702.4,2 F,B,C', 19, Combination-tyl)e AM breakere are reqUired at all locations requiring an AR I type breaker, 20, Carbon inonoxidealarnis will be required in new construction that uses fossil -bu rni ng heating or appliances or ariattached garage, "I"lit y s1rall be installed in accordance with the F,B,C, 2 1, All plutribing, mechanical, and electrical shall be separate froin unit to unit, 'This includes all underground plumbing and electric, 22, All 2016 N.E.C. Codes will be enforced, 23, Taniper-, Resistant Receptacles in accordance with 406,11 of the 2016 NJ,'-(' 24, In accordance with the I .and Dexelopment Code, lots shall be sodded before fit at at least 10 feet around the structure, 25. 1 03,5,3Hot water pipe insulation Insulation for hot water pipe with a rninimum thermal resistance (R-value) of R-3 shall be applied to the following, Piping I, inch (19A rnm) and larger in nominal diarneter, Piping seRting more than one dwelling unit, Piping located outside the conditioned space, Piping from the water heater to a distribution manifold. Piping located under a floor slab, Buried in piping, Supply and return piping in recirculation systems other than dernand recirculation systems, 25. Bloi%vr door test shall be provided before C.O. 26 11 dines. 277@ I , erinit be 'isne ir, aL 2& this ermA F.F.E.-Finished Floor Elevation F.B,C- Florida Building Code 6t" Edition R,O.W.-Right of Way A.D.A.- Americans with Disabilities Act N.E.C.- National Electric Code (2016) 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department ate, Received MMoyes@drhorton.com Phone Contact for Permitting I Nner's Name DR Horton Inc Owner Phone Number 1813-549-1968 uvnerl s Address 1 12602 Telecom Drive; Tampa, FL 33637 Owner Phone Number )e Simple Titleholder Name I Same Owner Phone Number )e Simple, Titleholder Address 013 ADDRESS LOT # JBIDIVISION Abbott Park (Zephyr Lakes) PARCEL I D# F (OBTAINED FROM PROPERTY TAX NOTICE) 'ORK PROPOSED NEW CONSTR 8F7 ADD/ALT SIGN DEMOLISH INSTALL REPAIR ROPOSED USE SFR COMM OTHER '(PE OF CONSTRUCTION BLOCK FRAME STEEL ESCRIPTION OF WORK UILDING SIZE I = SO FOOTAGE= HEIGHT N/A BUILDING LN/A VALUATION OF TOTAL CONSTRUCTION N/A ELECTRICAL $ N/A AMP SERVICE PROGRESS ENERGY W. R. E. C. NIA PLUMBING $ N/A NIA MECHANICAL $ N/A VALUATION OF MECHANICAL INSTALLATION [E] GAS ROOFING SPECIALTY = OTHER INISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO UILDER COMPANY IGNATURE REGISTERED Lyl NFEE CURREN Address I License LECTRICIAN COMPANY I IGNATURE REGISTERED L_yj N FEE CURREN Address License# I [,L�awnMedic Landscape & Irrigation LUMBER COMPANY IGNATURE REGISTERED Y/N FEE CURREN N Address 4827 Beauchamp Rd; Plant City, FL 33563 License # I SCCI 31152084 JECHANICAL COMPANY IGNATURE REGISTERED Y/N FEE CURREN Address I License # )THER COMPANY IGNATURE REGISTERED Y / N FEE CURREN Address License #— Is all I was a I full as 112112.4 Wallis was its vitalist -WIN as 111INIS-1112 13.4 Wiss 14 IESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction, , Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects *MMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance ;IGN PERMIT Attach (2) sets of Engineered Plans. —PROPERTY SURVEY required for all NEW construction. )Irectlons: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (A/C upgrades over $7500) k Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same )VER THE COUNTER PERMITTING (copy of contract required) Ieroofs if shingles Sewers Service Upgrades A/C Fences (Plot/SurveylFootage) Driveways -Not over Counter if on public roadways..needs ROW 813-780-0020 City of ZephyrhiUsP8rmit Application pax-813-780-0021 Building Department NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009. Furthen-nore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" ofthis application for which they wfl I be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and -Consumer Affairs, If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. CONTRACTO RISIOWN ERIS AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. � Southwest Florida Water Management Diothot4We||a' Cypress Bayheada, Wetland Areao, Altering VVoharooureea. - Army Corps of Engineers -Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-VVeUe, Wastewater Treatment, Septic Tanks. ' UGEnvironmental Protection Agency -Asbestos abatement. - Federal Aviation Authority-Runvvaya. | understand that the following restrictions apply tnthe use nffill: - Use offill ianot allowed inFlood Zone "\y'unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed bythe State ofFlorida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wm|| construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, l certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect ocUooent propartiea, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots |eoa than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth inthis affidavit prior m commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered WARNING TOOWNER, YOUR FAILURE TORECORD ANOTICE OF COMMENCEMENT MAY RESULT !NYOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT OWNER OR AG-Em ;,A I &Z� CONTRACTOR Subscribed and sworn t (4 affirmed) before mallhis Subscribed and sworn to (or affirmed) before me this Wh is are personally known tome orhas/have produced Who is/are personally known to me or has/have produced as identification. as identification, Com mission No., Name of Notary typed, printed or stamped HEATHER MUNDT Commissiu #GGS45409 ExpimmMay 3,2024 -ror*n- mn&dmm&**w*vmvAm Commission No Name of Notary typed, printed or stamped Notary Public PLOT PLAN DESCRIPTION:(AS FURNISHED) LOT 10, BLOCK 4, ZEPHYR LAKES SUBDIVISION PHASES 1B AND 1C AS RECORDED IN PLAT BOOK 84, PAGE(S) 85-90, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. Curve Table Curve # Length Radius Delta Chord Bearing Chord C1 90,97' 255.00' 20-26'20- N5992'01 -E 90,48- C2 236,20T280,00' --Z �2000" 6W32'00'E 229.26' C3 118.66' 280.00' 24'16'49" N81*33'36"E 117,77' C4 117.55' 280.00- 24-03-11- 57'23-36-E 116,68' 00 n. 1" = 30' 22APH& �S�6A6 IT 15 30 ON LOT CALCULATIONS LOT = 9,474 SQ. FT, LIVING AREA = 2,034 SQ. FT. GARAGE = 459 SQ. FT, ENTRY = 28 SQ. FT. LANAI = 218 SQ. FT. SLAB = 24 SQ. FT. DRIVEWAY = 418 SQ. FT, A/C PAD = 12 SQ. FT. WALKWAY = 31 SQ. FT, IMPERVIOUS = 34% = 3224 SQ. FT. SOD = 6,250 SQ. FT. OFF LOT CALCULATIONS RIGHT OF WAY = 1213 SO. FT. DRIVE APRON = 152 SO. FT. PUBLIC S/W = 459 SQ. FT. SOD = 602 SQ. FT, TOTALS AREA = 10,687 SQ, FT. DRIVEWAY = 570 SQ. FT. SIDEWALK = 490 SQ, FT, SOD = 6,852 SQ. FT. �s Tl� PREPARED FOR: G� 11 N BUILDING SETBACKS FRONT: 20'* GARAGE: 25' REAR: 15'* SIDE: 5' SIDE STREET: 15' STAGGERED FRONT SETBACK= PG 25' FRONT THEN 27' FRONT, . — —1— REAR a. v 1 SETBACK CAN BE REDUCED TO 13' NOTES: 1. PROPOSED ELEVATIONS SHOWN HEREON ARE BASED ON THE APPROVED ENGINEERING PLANS PREPARED BY HAMILTON ENGINEERING & SURVEYING INC.. 2. ELEVATIONS ARE BASED ON NAVD 1988 DATUM. THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF THE PROPOSED HOUSE, REFER TO HOUSE PLAN AND OPTION LIST FOR CONSTRUCTION, ALL BUILDING SET BACK LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT AND IS FOR INFORMATIONAL PURPOSES ONLY. THIS IS NOT A SURVEY THIS IS A PLOT PLAN ONLY LOOD NOTE: I HAVE EXAMINED THE F.I.R.M. MAP NO, 12101CO293F. ATED 09/26/2014, AND FOUND THE SUBJECT PROPERTY APPEARS TO LIE ARTIALLY IN ZONE *X & AE'. ZONE 'X". AREAS DETERMINED TO BE BEARING BASIS: BEARINGS SHOWN HEREON ARE BASED ON THE WESTERLY LINE OF LOT 10 BLOCK 4 BEING N20*34'49"W, PER PLAT. (FIELD DATE:) SCALE: 1* = 30 FEET APPROVED BY: JB - 210324 LOT 10, BLOCK 4 JOB NO. DRAWN BY: —2-8 BUILDING SETBACK LINE CENTERLINE RIGHT OF WAY LINE PROPOSED ELEVATION PROPOSED DRAINAGE FLOW CONCRETE A/C AIR COND111ONER S/W SIDEWALK Pi POINT OF INTERSECTION PC PONT OF CURVATURE PT POINT OF TANGENCY RP RADIUS POINT PRC POINT OF REVERSE CURVATURE PCP PERMANENT CONTROL POINT TYR TYPICAL CS CONCRETE SLAB (P) PER PLAT (C) CALCULATED PB PLAT BOOK PGS PAGES SQ, FT. SQUARE FEET F * E.M,A. FEDERAL EMERGENCY MANAGEMENT AGENCY F.I.R.M. FLOOD INSURANCE RATE MAP NAVD NORTH AMERICAN VERTICAL DATUM D&UE DRAINAGE & UTILITY EASEMENT D&AE DRAINAGE & ACCESS EASEMENT DE DRAINAGE EASEMENT UE PUBLIC UTILITY EASEMENT SURVEYOR NOTES: 1. THE SURVEYOR HAS NOT ABSTRACTED THE LAND SHOWN HEREON FOR EASEMENTS, RIGHT OF WAY, RESTRICTIONS OF RECORD WHICH MAY AFFECT THE TITLE OR USE OF THE LAND, 2, NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCATED EXCEPT AS SHOWN. 1 NOT VALID WITHOUT THE AUTHENTIC ELECTRONIC SIGNATURE AND THE AUTHENTIC ELECTRONIC SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. Digitally signed by James Boleman DN -US,stRmids,1=00andc, —American S—eying & Mapping, .—I'l.felimal Land Survey.,, email=jbol.manc&asmcorpo,ate.com FOR D-2021AL0414:42:54-04'00' THE Ad.brAc.bat—,k,n 11.0.23 FIRM JAMES W. BOLEM-AN PSM# 6485 DATE