Loading...
HomeMy WebLinkAbout21-33935335 Eighth Street Zephyrhills, FL 33542 Phone: (813) 780-0020 Fax: (813) 780-0021 ELCMISC-003393-2021 Issue Date: 12/28/2021 REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. L Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. P44 *jr, CONTRACTOR SIGNATURE E IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION 10 RAU 0 a :01 Ji &TA :r-ATA 813-780-0020 0 Fax-813-780-0021 6073 4622 WISTERIA DR 15-26-21-0160-00000-CI370 oil ��Aiffffm t. INSTALLATION OF PHOTOVOLTAIC SOLAR PANELS ON ROOFTOP P ot K:]ELECTRICAL $55,970 AMP SERVICE PROGRESS ENERGY = W.R.E.C. =PLUMBING t =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS ROOFING [:] SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER z COMPANY Momentum Solar SIGNATURE ameron ChristensenREGISTERED L11N_J P'F—E CURREN Address 6210 Hoffner Ave Ste 100 Orlando FL 32822 License #EVC57038� � ELECTRICIAN COMPANy Momentum Solar SIGNATURE Matthew Frans REGISTERED Address 6210 Hoffne-r-Aye St. 100 Orlando FL 32822 Licenss# EC13008217 PLUMBER COMPANY SIGNATURE REGISTERED / N _FEE N Address License # MECHANICAL COMPANY SIGNATURE REGISTERED L_YLN_j FEE CURREN Y/N Address License # OTHER COMPANY SIGNATURE REGISTERED L_X.LN_j FE15 CURREN L_yj N_J Address License III RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for now construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ SIR Fence installed, Sanitary Facilities & 1 dumpster, Site Work Permit for subdivisionallarge projects COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Sift Fence installed, Sanitary Facilities & I dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans, ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (A/C upgrades over $7500) Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Rerooft if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage) Driveways -Not over Counter if on public roadways..needs ROW 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department NOTICE OF DEED RESTRICTIONS: The undersigned understands that this pennit may be subject to "deed" restrictions" which may be more restrictive than County regulations, The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500,00 or more, I certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner, I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all wok will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction, I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, WaterA/Vastewater Treatment. - Southwest Florida Water Management District -Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers -Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency -Asbestos abatement, - Federal Aviation Authority- Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone'V" unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in Connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stern wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned, laffillUMMILTIM41 _b Who is/are personally known to me or has/have produced as identification. —Notary Public Commission No. Name of Notary typed, printed or stamped ��'tpnqpn r son_M�ly knowntoin othas/have produced —as identification. as Notary Public Commission No.6 a'2 Ek Name Nfoary �Iypeprintad War stamped "0110, ELIZABETH DINO 4f< B JA t te or ' da - N ' I a y Public State of Florida -Notary # G G 178362 C Commission # GG M y mm 1 0 r Co , Expires res My Commission Expires 0 ry , 022 January 24, 2 2 Permit Number: Folio/Parcel ID pC1 7 Prepared by: MOM[=-NTVM SOLAR t kyla keen 6210 Haffner Ave. Ste 100 Orlando FL 32822 Return to: S: M0mENLTvN_SOLAR var, Orlando FL 32822 NOTICE OF COMMENCEMENT State of Florida, County of PASCO The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. I Description of property (legal description of the property, and street address if available) WHHISPERING OAKS PB 14 PG 86-87 LO 37 & E1/2 LOT 38 - 4622 WHISTERIA DR 2, de—neral description of —Improvement INSTALLATION OF PHOTOVOLTAIC SOLAR PANELS ON ROOFTOP AEL ADWELL —information or Lessee Information If —the Lessee contracted for the improvement Name MICH Address4622 WHISTERIA DR ZEPHYRHILLS, FL 33542 Interest Name and address of fee simple titleholder (if different from Owner listed above) Name Name - MOMENTUM SOLAR Number 321-247-6073 —Telephone Addre$S_h2LQH iaadQ1_L3ZQ22__ off nff_Ayl;L_$�QA 5, Surety (if applicable, a copy of the payment bond is attached) Name N/A ---,Telephone Number Address --Amount at Bond 6, Lender Name r ----Telephone Number— ---- Address T Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by t713.13(1)(a)7, Florida Statutes, Name — N/A s u.--Telephone Nurnber-- Address & In addition to himself or herself, Owner designates the following to receive a copy of the Lienor's Notice as provided in §713.13(1)(b), Florida Statutes, Telephone Number, Address 9. Expiration date of notice of commencement (the expiration date will be I year from the date of recording unless a different date is specified) OWNER Signature of Owner or Lessee, or Owner's or Lessee's Authorized Officer/Director/Partne IM Signatory's Title/Office The foregoing inst ent was kno dgod before me by means of presence or online iq; notarization, th, day of f. by MICHAEL ADWELL Anth"ar name of person as OWNER -for Type of authority: owner rusted, attorney in fia, ignature of Nota Public — State of Florida PersonallyOR Produced ID X — Type of ID Produc�d DRIVERS LICENSE Form content revised: 01101/20 Name of party on behalf of whom instrument was executed ELIZABETH DINO ELIZABETH DINO " d a N 02022 to r y Public b I'c r ; (3(3 1 7 83 62 0 F7 !on L W S $1 t f tate of Florida -Notary Public Commission # GG 178362 M Commission M, 5 a' 0 n Expires p "a s My Commission Expires j January 0 January 24, 2022 DocuSign Envelope ID: 5AI 14ED9-4A59-4628-9F69-4FAA03ED02DA THIS IS A COPY The Authoritative Copy of this record is h0d at na2,docusjgn.ne1 momentum SOLAR SOLAR ELECTRIC INSTALLATION CONTRACT Michael Adwell Customer Name Service Address City, State, Zip (813) 763-9544 Bentleyadwell@yahoo.com Phone Email Address Duke Energy Florida (prev. P Iress Ene Flori e Energy 7 S-72-2-US go" PLU •ZE iMined by your third -party finance company, We are not affiliated with any third -party finance compa y I IKA 4&^# A •R: $41,440.00 (PLUS ANY APPLICABLE SALES TAX) I K-1 SohrAijigil tju al#j'111� tj ill ff-al KAI' fro, 1 "AMIN TOTAL AMOUNT PAYABLE TO MOMENTUM SOLAR: $41,440. Optional Down Payment: $0.00 Upfront Rebate (if applicable): $0.00 Total Loan Amount: $41,440. Document.24 FL Page 1 of 10 DocuSign Envelope ID:5A114ED9-4A59-4628-9F69-4FAA03ED02DA O° "' e. "uthorit tiv :.op Rif this record€s tiel. ,t na ,.4ocusign,€el momentum You acknowledge that, regardless of whether you obtain financing from a third party, we require payment in full upon completion of the installation (and required inspections) and that we are not extending credit to you in connection with this transaction, ACCORDING TO FLORIDA'S CONSTRUCTION LIEN LAW (SECTIONS 713.001-713.37, FLORIDA STATUTES),THOSE WHO WORK ON YOUR P TY OR PROVIDEMATERIALS IAL AND SERVICES AND ARE NOT T PAID IN FULL HAVE A RIGHT TO NF C THEIR L I FOR PAYMENT AGAINST YOUR PROPERTY. THIS CLAIM IS KNOWN AS A CONSTRUCTION LIEN. IF YOUR CONTRACTOR OR A SUBCONTRACTOR FAILS TO PAY SUBCONTRACTORS, SUB-SUBCONTRACTORS, OR MATERIAL SUPPLIERS, THOSE PEOPLE H MONEY MAY LOOK TO YOUR PROPERTY FOR PAYMENT, EVEN IF YOU HAVE ALREADY PAID YOUR CONTRACTOR IN FULL. IF YOU FAIL TO PAY YOUR CONTRACTOR, YOUR CONTRACTOR MAY ALSO HAVE A UEN ON YOUR PROPERTY. THIS MEANS IF A LIEN IS FILED YOUR PROPERTY COULD BE QLD AGAINST YOUR WILL TO PAY FOR LABOR, MATERIALS,OR OTHER SERVICES THAT YOU O PVT CTOR OR A SUBCONTRACTOR MAY HAVE FAILED TO PAY. TO PROTECT YQU ELf `Y 1OULD STIPULATE IN THIS CONTRACT THAT BEFORE ANY PAYMENT IS MA C 1T� .FOR IS REQUIRED TO PROVIDE YOU WITH A WRITTEN RELEASE OF UEN FROM Y3 PERS'O N OR COMPANY THAT HAS PROVIDED TO YOU A "NOTICE TO OW 4E W,1 FL A'S Ct STRUCTiON LIEN LAW IS COMPLEX, AND IT IS RECOMMENDED THAT `OtCO _L1 AN ATT NEY. Pro Custom Solar LLC d/b/a Momentum Solar is a certified spar contr �tor( #V� $ 6)with the Department of Business Professional Regulation. { General Tms and Co ns Definitions: In this agreement, the terrrt& t Amer" "owner", and "you" refer to the customer identified above, and the terms "contra ', u�'t and" " refer to Pro Custom Solar LLC d/b/a Momentum Solar and its employees, agents ar subcornactors, E applicable. The term "agreement"or"contract" refers to this agreement between you d u $ td any ch ge orders signed by you and us. "PV System" means the solar panels an a`` °d the system of solar energy generation described above. Scope of 1lork. We agree tOlell ~ d install the PV System on your real property. We will not provide, or arrange for chi ctural/en �eerit g services or structural changes to dwellings or buildings unless we expreøy agree to so in separate writing signed by us. We have the right to determine the method, detail d and means I1 truing the work, We will obtain the necessary building and electrical permits and ensure codØ compliance. You agree to cooperate with us to obtain these permits and meet code compliaçe, YoU are solely responsible for obtaining, at your own cost and expense, any and all zoning variances : q'fed by any municipality or local governing body. We will not obtain a zoning variance for you unless we expressly agree to do so in a separate writing signed by us. Change Orders: Any change to the work or the installation schedule that you or we request will be set out in a written change order signed by both you and us. You agree that a change order may result in a change to the terms of the agreement between you and us, including but not limited to, the contract price and the anticipated installation schedule. If you request, in writing, a change to the scope or performance of the services provided under this agreement, then we will provide you with a written change order for your approval within a reasonable time after such written request. You agree that we may issue a change order if a Force Majeure Event (as defined below) occurs that changes or impairs our ability to perform under the current terms and conditions of this agreement. All change orders, including a change order resulting from a Force Majeure Event, must be approved in writing by you within a reasonable time after receipt, and you agree not to unreasonably withhold your approval of any change order. Time Period: We anticipate beginning work under this agreement within fourteen (14) days after we receive all required paperwork from the applicable state, utility, and municipality. We anticipate that we Document.24 FL Page 2 of 10 DocuSign Envelope ID:5A114ED9-4A59-4628-9F69-4FAA03ED02DA he a tho tafiv� Copy oft is rec r is hod{it �a .. o i a,r i momentum will complete the work within thirty (30) days after we begin. This is our best estimate and is subject to change according to various factors outside of our control. We are not responsible for delays resulting from any Force Majeure Event (as defined below). Force aieure: We will not be liable to the you for any failure or delay in performance under this agreement caused by events beyond our control including, without limitation: negligence or delay by any governmental entity or utility company; your noncompliance with this agreement; your failure to furnish necessary information or furnishing of incorrect information; legal encumbrances on your property; your property's non-conformance with building codes or zoning requirements; your credit rating or financing arrangements; acts of God, nature, government or any third parties; war or acts of terrorism; labor strife or disputes; shortages of labor, fuel, raw materials or equipment; technical failures; accidents sabotage; failure or delays in transportation or communication; failures or substitutions of equipment; ohidden or unforeseen physical or hazardous conditions, including but not limited to, environmentzarc such as mold, asbestos, and lead paint (each, a "Force Majeure Event"). Your Reaponsibilliltios; You agree to pay us for merchandise delivery and tall' n the System according to the terms and conditions of this agreement. If your I'be addres g ssubje o any easements, covenants or other legal encumbrances that could affect the tnstattâtion, yitigree to notify us in writing, including by electronic mail or by certified mail, with! fj (5)` *ess days ofyour becoming aware of the encumbrance or prior to our beginning work, whi Pev s e� er Yoh gree to ensure that work areas are free of preexisting hazards, includint,but noimrt to taó physical conditions or environmental hazards and building/zoning code violate o Yo t gre&t al' us access to work areas during work hours. If you have a security system, you jree tD ensue that it does not interfere with installation. You agree not to allow unattended minors at the� çvze address while we are performing the installation. You agree to control pets ançl kee them away fro ; work areas. You agree that, if anyone under your control interferes with oc,ttla �ation, you may be subject to transportation and/or storage charges or other resulting char , Payments= All payments mt.4t b shade in ch, by credit card, or by check(s) made payable to "Momentum Solar"as�rI$ ,kthI agreement. Any payments you owe under your agreement with the third-party financompanyuatbe made in accordance with the terms of your agreement with them. Failur , Yi will be inbreach of this agreement if you fail to make any scheduled payment on time, in full Ind otherwi in accance with this agreement. if we have not received the full amount of any schedled payment iWM ten days after the scheduled due date, you will incur a late fee equal to one perce (1%) oft unpaid amount due, if the installation is not completed when the breach occurs, we resenr tie right1b suspend all work until all past-due amounts have been paid in full. If the PV System is in operát1ot when the breach occurs, we reserve the right to remotely shut off the PV System until all past-due amounts have been paid in full. Subject to applicable law, we may also pursue amounts you owe us through legal action, which may include perfecting or enforcing a lien against your property or the PV System. If we take legal action to enforce this agreement, you agree, to the maximum extent permitted by applicable law, to pay reasonable attorney's fees and costs we incur before and after judgment and any other costs permitted under applicable law. if you fail to pay your third-party finance company pursuant to the terms of your agreement with them, you may be subject to any of the terms and remedies set forth in that agreement. Please consult that agreement to determine your liability and rights regarding the third- party finance company. inspection of System: You agree to allow us, our designees, and any state or local governmental authority or utility company to inspect the PV System at the service address. Cancellation by Customer: If you cancel this agreement at any time after the cancellation period described in this agreement or otherwise prevent us from completing the installation, you agree to Document.24 FL Page 3 of 10 DocuSign Envelope ID:5A114ED9-4A59-4628-9F69-4FAA03ED02DA THIS I TIC£ r``uti`o it ati`e k.i't y of t'is rec rd is theld t n a ,C ocu cigin t e! momentum reimburse us in full for the cost of materials, labor, and services provided up to the date and time of cancellation. Termination by Momentum: Prior to beginning design and permitting work, we will perform a physical assessment of the installation site, including suitability of the existing electrical panel and wiring, roof condition and shading of the intended location of the PV System to verify the suitability of the site for the PV System. If we determine that existing site conditions will not allow for installation of a PV System as described at the top of page 1, we may terminate this agreement if you and we are unable to agree to modifications needed to provide for additional work needed to make the site suitable for the PV System. If we do so terminate this agreement, we will refund your initial deposit in full. We may also terminate this agreement after completion of our site assessment without further obligation if either (a) you breach this agreement, or (b) we discover or become aware of: (i) previously undisclosed legal encumances or easements affecting the service address, (ii) building/zoning code violations at the servi ddrs, or(iii) hidden or unforeseen hazardous conditions such as the presence of mold, asbestos, t,,pai fl , or any other conditions not disclosed to us. Gomoonent Manufactc rer's Warranty: The manufacturers of cep hh of the iv ystem ` major components warrant their components against certain defects. We ha provided you wttli copies of all manufacturer's warranties which govern your rights to seek a r m y f The respective'`manufacturer with respect to covered defects. Limited Wa�rra y: You agree to contact us in writing, hidtu,ding ele nick il or by certified mail,with any problems or issues with the installation as 'oon asp ; bl but Enna y event within thirty (30) days from the date you become aware of such prblem. We wMI e reasonable measures to remedy or otherwise resolve the problem within t, arty (!*3) days after receive your notice. You agree and acknowledge that our limited warrt d the installation only for a period of ten years. The limited warranty does not apply if: (1 you 1 to`ñfy us of the problem within thirty (30) days, or (2) it is reasonably determined, upon41 pectr 3 = following 0 that a ,of the conditions caused the need for service: (a) damage resulting frQi ac� ntits of God, alterations or misuse; (b)your failure to properly follow the operating instr s (c)II wage caused by animals; (d) alterations to your premises; or (e) alterations to the PV SysteM ma4 at your request, or made necessary by a change to your premises, damage to your Y miser, otn �►er cause beyond our control. The PV Systemincludes a monitoring �`th Y` , \b rSN platformarlloW us to rote access performance information for the purpose of assessing the soures of perform6$0p issu s hat need to be remediated. Additionally, we warrant that any penetrations of yout roof used rs the tMteiration will not leak for a period of five(5)years. The limited roof penetrations warran* does not apply if: (1) you fail to notify us of the problem within thirty (30) days, or (2) it is reasonr detained, upon inspection, that any of the following conditions caused the need for service: (a) damn m ting from accidents, acts of God, alterations or misuse, (b) damage caused by animals; (c) alterations or damage to your premises; or(d) any other cause beyond our control. NO OTHER WARRANTIES: THE "LIMITED WARRANTY" RELATING TO OUR INSTALLATION OF THE PV SYSTEM OR "COMPONENT MANUFACTURER'S WARRANTY" RELATING TO THE VARIOUS COMPONENTS OF THE PV SYSTEM PROVIDED BY THE APPLICABLE MANUFACTURER, ARE THE WARRANTIES PROVIDED UNDER THIS AGREEMENT. WE MAKE NO GUARANTEE NTEE OR WARRANTY OF ANY KIND THAT EXTENDS BEYOND THE FACE OF THIS AGREEMENT, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO THE SERVICE PERFORMED OR THE SYSTEMS PROVIDED UNDER THIS AGREEMENT. LIMITATION OF DAMAGES: TO THE MAXIMUM EXTENT PERMITTED BY LAW, YOU AGREE TO RELEASE US FROM ALL LIABILITY TO YOU OR ANY OTHER PERSON FOR ANY INCIDENTAL, Document.24 FL Page 4 of 10 DocuSign Envelope ID:5A114ED9-4A59-4628-9F69-4FAAo3FDo2DA I t r t e ritativc 'a a ₹tP i record is :d t Eraa2,dom ign, el momentum CONSEQUENTIAL OR PUNITIVE DAMAGES EXCEPT TO THE EXTENT SUCH DAMAGES ARE CAUSED BY OUR GROSS NEGLIGENCE OR WILLFUL MISCONDUCT. finding ature: This agreement shall bind and inure to the benefit of the respective heirs, personal representatives, successors, and permitted assigns of each party. Entiret o Contract• Modification° aiver: This agreement constitutes the complete agreement between you and us concerning the subject matter of this agreement and supersedes and cancels any and all prior communications, representations, and agreements between you and us, whether written or oral, with respect to the subject matter of this agreement. This agreement may not be amended or modified unless in writing and executed by you and us. The rights and remedies of both partieunder this agreement are cumulative and not alternative. No waiver of any breach or failure to enforce or tsist upon performance any of the provisions of this agreement by either party at any time will in array affect, limit or waive such party's right to enforce and compel strict compliance with every provision t$ttdsagreement. The invalidity or unenforceability of any provision of this emerft h not pct the validity or enforceability of any other provisions of this agreement, wh4 y `'shall rem ti full fie and effect. Assis�nment. Neither party may assign, transfer or delegate y o01 ll o is ri h$�or obligations under this agreement, without the prior written consent qf the other pI�y, 'consent shall not be unreasonably withheld or delayed; Qjded however, t (a) t ', conk ctaray assign this agreement to any of its affiliates or to a successor of all or 1bstantiafly4 othee corW1actor's assets through merger, reorganization, consolidation or acquisition arts (b) such ant is not required for an assignment (absolute, collateral or otherwise), pledgeqf, or\\ rant of a secur thterest in, a right to payment under this agreement by either party. , ti r Dispute Resolution In the wont of a dbpute, bb you and we have the right to have the dispute resolved in a court of law. In th1 disptt r Sution prov1Ion, you and we are agreeing to limit that right. If you have any dispute v4ff ci f we any dispute with you, then both you and we must seek resolution of the dispute in either arbitrionr small claims court. if your dispute cannot be resolved in small claims court for aiiy reas ,, then yob mu*seek resolution of your dispute in arbitration. The arbitration hearing will be bkfbore nationall ecognized provider of arbitration services at a location of your choice within your l me state. ` I h rule � f the arbitration provider will apply. This dispute resolution agreement does not al r any subnf' . its that you may have under state or federal law. By signing below, you agree to com$Jy with this dispute resolution provision, which describes both your and our only procedure for resolvihny date. Only the arbitrator, not any federal, state, or local court or agency, has the authority to interprM t provision or determine its applicability or enforceability. If any provision of this dispute resolution provision is found to be unenforceable for any reason, such provision will be severed and the remainder of this dispute resolution provision will continue in full force and effect. You understand and accept that arbitration awards are subject to challenge only in limited circumstances. Document.24 FL Page 5 of 10 THIS IS A COPY The Authoritative Copy of this record is held at na2,docusign,nel momentum SOLAR Class action Waiver: ARBITRATION MUST BE ON AN INDIVIDUAL BASIS. AS A RESULT, NEITHE YOU NOR MOMT—NTUM MAY JOIN OR CONSOLIDATE CLAIMS IN ARBITRATION BY OR AGAIN OTHER "CUSTOMERS", OR LITIGATE IN COURT OR ARBITRATE ANY CLAIMS AS I REPRESENTATIVE OR MEMBER OF A CLASS OR IN A PRIVATE ATTORNEY GENERAL CAPACIT By initialing here, you agree to the terms of this paragraph: DS Customer Initials* F-�1 IS III a IN 61.01 In Document.24 FL Page 6 of 10 M THIS IS A COPY The Authorftaflve Copy of this record is held at nm2Aocusigmnel momentum SOLAR You, the buyer, may cancel this transaction at any time prior to midnight of the third business day after the date of this transaction. See the attached notice of cancellation form for al explanation of this right. MMUMf;� rZuSigned by: t6d A�Wta 11/16/21 =10 Document.24 FL Page 7 of 10 DocuSign Envelope ID: 5AI 14ED9-4A594628-9F69-4FAA03ED02DA THIS IS A COPY The Authoritative Copy of this record is held at 91a2,docusign,nel momentum SOLAR Notice of Cancellation You may CANCEL this transaction, without any Penalty or Obligation, within THREE BUSINESS DAYS from the above date. If you cancel, any property traded in, any payments made by you under the contract or sale, and any negotiable instrument executed by you will be returned within TEN BUSINESS DAYS following recei by the seller of your cancellation notice, and any security interest arising out of the transaction will b cancelled. 4'11111"Ilzl' I CWT-1ply,witri Me insirtutions OT Me seller regar,01% Me retarn snipillent expense and risk. • * 0 - 0000 - - - . 0 • I I WI:1 v go-moymiN, [egall WMMWI��� PM Document.24 FL Page 8 of 10 DocuSign Envelope ID: 5A1 14ED9-4A59-4628-9F69-4FAA03ED02DA THIS IS A COPY The AUthorits five Copy of thisrecord is held at na2,docusign,nee ..... momentum SOLAR Notice of Cancellation You may CANCEL this transaction, without any Penalty or Obligation, wn THREE BUSINESS DAYS from the above date. If you cancel, any property traded in, any payments made by you under the contract or sale, and any negotiable instrument executed by you will be returned within TEN BUSINESS DAYS following receipt by the seller of your cancellation notice, and any security interest arising out of the transaction will be cancelled. "d w 112=201 MEMEL= Document.24 FL Page 9 of 10 3*MMMN1= DocuSign Envelope ID: 5A1 14ED9-4A59-4628-9F69-4FAA03ED02DA THIS IS A COPY The Authoritative Copy of this record is held atna2,docrmign.ne'. %D momentum SOLAR Attachment 1 Mandatory Liability Insurance Obligation The Florida Public Service Commission, pursuant to Section 120.54, Florida Statutes, has adopted Rule 25-6.065, Florida Administrative Code, relating to interconnection and net metering of customer -owned renewable generation. Section (5)(e) requires that the owner of a Tier 2 renewable generation system have general liability insurance for personal and property damage of $1 million. A Tier 2 renewable generation system is one that is 11. 76 kW (dc) or 10. 0 kW(ac) or larger. Your local utility has interpreted this to mean that, in order to interconnect your solar generation systeri,p the local utility grid (and for it to function and provide you with the electricity it generates), you will had o pr0j, *Wde proof *111 that you have $1 million of general liability insurance as part of the application for intercoAW6000 `11th their system. By initialing here, you acknowledge that you understand the terms of d"Albe int atic if you fail to provide and maintain proof of this insurance: , . . .. . . F M, 4, stA r is: "000 $ Alternatively, an owner of a Tier 2 renewable gener,,",,\,\ion syste VV16­ f-ins is 1 million if it can demonstrate to the utility that the owner has suffice \`h financial rn cover a potential $1 million obligation. As part of the interconnection process, youN city will let y what information it needs from you to Oty will let y make this determination and the times ,,, -for ermination. Failure to provide proof of self -insure will result ina,\\,,,,' �' c� of such interconnectio-Al '7\\1"7 offset any electricif*V" used extra enerav, Your - I'll "stem 000 #4, 0 00^_ a suc"'�"urance\��,',,',,,',"'0,',t to 0 obtadapproval from the interconnecting utility to allow you to 17T , f y �j ,e4uest to moconnect your s termination enial i", otugg, system or, if interconnected, the o ,46terconnection, your system will not operate, you will not be able to in fur , to ,me and you will not be able to obtain any benefits of net metering any • Document.24 FL Page 10 of 10 a 0. PLAN KEY PV-1 COVER PAGE PV_1.1 ATTACHMENT DETAIL PV-2 ROOF LAYOUT PV-3 ELECTRICAL PV-3.1 ELECTRICAL CONT. Dx/-q 2 -, EQUIPMENT LABELS SYSTEM INFORMATION HANWHA Q.PEAK DUO BLK ML-G9+ 380 INVERTER ENPHASE IQ7PLUS-72-2-US ROOFTECH RT-APEX SYSTEM SIZE (DC) LOC ATION 28.2249767, -82.1916160 CLIMATIC & GEOGRAPHIC DESIGN CRITERIA TABLE momentum R301.2(1) SOLAR SPEED( PH} 140 PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH TOPOGRAPHIC EFFESTREET, METUCHEN, NJ 08840CTS B(732) 902-6224 MOMENTUMSOLAR.COM SPECIAL WIND REGION NO PROFESSIONAL WIND BORNE DEBRIS ZONE 2 ENGINEERING SEISMIC DESIGN CATEGORY C CLIMATE ZONE 2A WIND EXPOSURE CATET=ORY B GENERAL NOTES: A. IL THIS PV SYSTEM HAS BEEN DESIGNED TO MEET THE MINIMUM DESIGN STANDARDS FOR BUILDING AND OTHER STRUCTURES OF THE ASCE 7-16, 7TH EDITION 2020 FLORIDA RESIDENTIAL CODE, 7TH EDITION 2020 FLORIDA BUILDING CODE, 7TH HANWHA Q.PEAK DUO BLK ML-G9+ 380 EDITION 2020 FLORIDA FIRE PREVENTION CODE, NEC 2017 AND ALL LOCAL CODES & 380 WATT MODULE ORDINANCES. 72 44" X 40.5" X lt J 6,, 0 STATOF E (SEE DATASHE E ROOF SHALL HAVE NO MORE THAN TWO LAYERS OF COVERING IN ADDITION TO THE ;,6 SOLAR EQUIPMENT. '///;//OiVAL INSTALLATION OF SOLAR EQUIPMENT SHALL BE FLUSH MOUNTED, PARALLEL TO AND BILL OF MATERIALS NO MORE THAN 6-INCHES ABOVE THE SURFACE OF THE ROOF. MODULES 30 ANY PLUMBING VENTS ARE NOT TO BE CUT OR COVERED FOR SOLAR EQUIPMENT INSTALLATION. ANY RELOCATION OR MODIFICATION OF THE VENT REQUIRES A INVERTERS 30 PLUMBING PERMIT AND INSPECTION. ROOFTECH BASE 98 ALL DESIGN, CALCULATIONS ARE PERFORMED BY DANIEL DUNZIK REGISTERED MID CLAMP 69 ARCHITECT. FLORIDA STATE STATUTE 471.003(3) PROVIDES THAT LICENSED END CLAMP 24 ARCHITECTS ARE EXEMPTED FROM THE PROVISIONS OF CHARTER 471 ENGINEERING SOLAR CQNTMCTOR AND NOT PRECLUDED FROM PERFORMING ENGINEERING SERVICES FOR INTEGRATED CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 END SPLICE 5 SYSTEMS AND SERVICES THAT ARE INCIDENTAL TO BUILDINGS AND STRUCTURES. MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 END FLOATING SPLICE 4 INVERTER PLACEMENT.- CUSTOMER INFORMATION MICHAEL ADWELL - MS90914 MID FLOATING SPLICE 21 4622 WISTERIA DR SKIRTS 7 SYSTEM UTILIZES "ENPHASE" MICRO -INVERTERS WITH RAPID SHUTDOWN CONTROL ZEPHYRHILLS, FL 33542 LOCATED ON THE BACK SIDE OF EACH MODULE. 8136965771 ENPHASE COMBINER BOX I FBC, RESIDENTIAL 2020 E!Y SYS19M INFQRMATIQN STRUCTURAL STATEMENT, SYSTEM SIZE (DC): 11.4 KW EATON 60A FUSIBLE AC DISCONNECT 1 TABLE R301.2.1.3 30 MODULES: HANWHA Q.PEAK DUO BLK THE EXISTING STRUCTURE IS ADEQUATE TO SUPPORT THE NEW LOADS IMPOSED BY ML-G9+ 390 30 INVERTERS: ENPHASE 50A FUSES 2 THE PHOTOVOLTAIC MODULE SYSTEM INCLUDING UPLIFT & SHEAR.EXISTING RAFTER SIZES & DIMENSIONS CONFORM TO 7TH EDITION 2020 FLORIDA RESIDENTIAL WIND SPEED CONVERSION Sa IQ7PLUS-72-2-US 125A LINE TAPS 2 CODE MOUNTING BRACKETS AND HARDWARE MEET OR EXCEED FLORIDA CODE V.1t 110 115 120 130 140 150 160 170 180 190 200 REQUIREMENTS FOR THE DESIGN CRITERIA OF THE TOWN. Vasd 85 89 93 101108 116 124 132139 147 155 PR03ECT INFORMATION FSEC CERTIFICATION STATEMENT: INITIAL DATE: 11/24/2021 DESIGNER: NB PER FL. STATUE 377.705 , I, MINA A. MAKAR PE# 86753, CERTIFICATE OF For SI: 1 mile per hour = 0.447 m/s. REV: DATE: DESIGNER: AUTHORIZATION #33404, AN ENGINEER LICENSED PURSUANT TO CHAPTER REV: DATE: DESIGNER; 471,CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE B. Linear interpolation is DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT permitted. COVER PAGE VERSION OF THE FLORIDA BUILDING CODE. FBC 2020 1 13 0 0 MEN Universal Clamping / Slide In Mounting One Step Leveling / Integrated Flexible Flashing Proven PV mounting since 1994 WX c(a. @ FSR 3575 Intertek NICC11 CONSIDERED FROM AN ANGLE OF MIN. 9.5 TO MAX. 45* (1122) NOT TO EXCEED 30'MEAN ROOF HEIGHT ATTACHED WITH FASTENERS AS SPECIFIED BY THE MANUFACTURER. SPAN TABLES ARE DERIVED FROM MECHANICAL L110AX TESTS PAR MANUFACTURERS INDEPENDENT TESTING AGENCIES ON BEHALF OF THE MANUFACTURER. ROOF SEALANTS SHALL CONFORM TO ASTMC920 AND ASTM 6511 ALL ATTACHMENTS SHALL BE INSTALLED IN STRICT COMPLIANCE WITH MANUFACTURERS PRINTED INSTRUCTIONS. installation Item & Part Number Install Base and End damp Sirda In nti RT-APEX Base (RT3-00-AXSK) -,4 ewlz- RT- Apex Base; 24 ea. SD5-60 Screws; 48 ea. ------ Adddonal RT- Butyl; 12 e& Wkils, Clamp (RT3-02-UM-SK) M.Ue Elm" Spike (RT3-02-UMFSSK) Middle Clamp Splice (RT3-02-UMSW) 41-6 -4-0 -- MkUo clamp; 12 ea. End Clamp (RT3-02-UE-BK) End Floating Splice (RT3-02-UEFSM) End amp SpIwe (RT3-02-VESSK) .4-1*- � A 0— - End Clamp ; 12 ea- RT-APEX Skirt (RT3-03-SK80BL) 4*4� RT- Apex Skirt Wnch; 8 ea. material -pew Description sas-. --- I Clamps Anodized aluminum Hardware Ttainfpss steel VlexbWF4; fif BiAVI (KC ESR 3575) 25 Year Limited Warramy PAT PENDING GUTTER G 2 (2) RIDGE (3) (2) (Z T (3) Q GUTTER exi S m o m e n t u m SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 (732) 902-6224 MOMENTUMSOLAR.COM MIT' CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 MICHAEL ADWELL - MS90914 4622 WISTERIA DR ZEPHYRHILLS, FL 33542 8136965771 t(elz ML-G9+ 380 30 INVERTERS: ENPHASE IQ7PLUS-72-2-US I INITIAL I DATE: 11/24/2021 1 DESIGNER: NB I II r!�lMJ,IIi BELOW 30'-0" MEAN ROOF HT. 13 SCALE: 1/8' f V-0" �wvtogmgwj LANDICAREMAXIPAN I PORTRAIT MAX SPAN LANDSCAPE MAX PORTRAIT MAX PANEL COUNT (ROOF ARE (ROOF AREA 1 2/3) CANTILEVER CANTILEVER NOTE: 1. ROOF COVERING MATERIAL IS COMPOSED OF SINGLE LAYER ASPHALT COMPOSITE SHINGLE, 2. REFER TO LAYOUT DETAIL DRAWING PV-3 FOR ALL ROOFTOP DIMENSIONS. DRIVEWAY momentum SU-I'AR PRO CUSTOM SOLAR LLC D.B.A. MOITjENTUM SOLAR 325 HIII IGH STREET, METUCHEN, N) 08840 (732) 902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD, SUITE 307, ORLANDO FL 32819 USTOMER INFORMATION SYMBOL LEGEND MICHAEL to - MS90914 4622 WISTERIA DR ZEPHYRHILLS, FL 33542 MAIN SERVICE PANEL 8136965771 SUB -PANEL PIZ] '#?� a w-, ML-G9+ 380 30 INVERTERS: ENPHASE I 7PLUS-72-2-US AC I Disc AC DISCONNECT 0 PIPE VENT UDC(d) UTILITY DISCONNECT FAN ElLOAD CENTER i7IJ SATELLITE DISH NEMA 3R BOX W/ ENVOY-S FIRE SETBACKS INITIAL REV: CBCOMBINER BOX MIN 3' XTGROUND ACCESS P0114T REV: 0 t MODULE PITCH DIRECTION WIND PRESSURE ZONE LINES. REFER TO PV-2.2 FOR ADDITIONAL INFO II PV MODULE RATINGS INVERTER RATINGS VOLTAGE DROP CALCULATIONS MODULE MAKE HANWHA INVERTER MAKE ENPHASE FORMULA USED PER NEC HANDBOOK 215.2(A)(4) WHERE APPLICABLE Q.PEAK DUO BLK IQ7PLUS-72-2- WIRE RUN VMP imp R L (FT) VO % VO WIRE SIZE momentum MODEL ML-G9+ 380 MODEL us SOL-AR - BRANCH TO ]-BOX 240.00 12.1 1.98 65.83 3.154 1.31% 12 AWG MAX POWER 38OW MAX OUTPUT POWER 290W PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR ]-BOX TO LOAD 325 HIGH STREET, METUCHEN, NJ 08840 OPEN CIRCUIT VOLTAGE 45.04V OPEN DC VOLTAGE 60V 240.00 36.3 1.24 50.00 4.501 1.88% 10 AWG (732) 902-6224 CENTER MOMENTUMSOLAR.COM MPP VOLTAGE 37.85V NOMINAL AC VOLTAGE 240V LOAD CENTER TO AC 240.00 45.375 0,491 3.00 0.134 0.06% 06 AWG PROFESSIONAL SHORT CIRCUIT CURRENT 10.5A MAX AC CURRENT 1.21A DISCONNECT ENGINEERING MPP CURRENT 10.04A CEC INVERTER EFFICIENCY 97% AC DISCONNECT TO 240.00 45.375 0.4=91 10.00 0.446 0.19% 06 AWG NUMBER OF MODULES 30 INTERCONNECTION NUMBER OF INVERTERS 30 UL1703 COMPLIANT YES 11 1703 COMPLIANT YES PV B SUB PANEL # OF MODULES PER BRANCH THIS SOLAR PHOTOVOLTAIC SYSTEM COMPLIES WITH THE 2020 ♦111/ BREAKER SIZE FLORIDA BUILDING CODE AND THE 2017 NATIONAL ELECTRICAL CODE UP TO 16 20A FSEC CERTIFICATION STATEMENT: GE 30 HANWHA Q.PEAK DUO BLK ML-G9+ 380 380W MODULES PAIRED WITH PER FL. STATUE 377.705 , I, MINA A. MA PE# 86753, % CERTIFICATE OF AUTHORIZATION #33404, AN ENGINEER 30 ENPHASE IQ7PLUS-72-2-US MICRO -INVERTERS LICENSED PURSUANT TO CHAPTER 471,CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING 1 0STATE OF ---- - --- ---- CODE, FBC 2020 40RIDP' C, BRANCH CIRCUIT A EXISTING GENERAL 10 MICRO -INVERTERS ELECTRIC 200A MAIN L. BRANCH CIRCUIT B SERVICE PANEL 240 V 1111111WN 10 MICRO -INVERTERS BRANCH CIRCUIT C MAIN BREAKER: 200A 10 MICRO -INVERTERS ENPHASE 80A LINE SIDE + AC COMBINER SOLAR CIRCUIT _4 / - HOT TAP BOX DISCONNECTING MEANS 200A EATON 60A FUSIBLE AC GRID DISCONNECT 8 SOLAR CONTRACTOR ------ - ------- E ;' i fl- ---I CAMERON CHRISTENSEN 8 CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 50A I MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL 32819 CUSTOMER INFORMATION 10� ROOF 1 OA/1 5A BREAKER -j-POWER UTILITY MICHAEL ADWELL - MS90914 JUNCTION (MANUFACTURER 'GROUND METER 4622 WISTERIA DR �c 50A FUSES ZEPHYRHILLS, FL 33542 BOX SUPPLIED FOR TERMINATION CAP 1 2A-C ENVOY) 3 4 8136965771 INSTALLED ON 20A BREAKER (A) PV SYSTEM INFQRMATION END OF CABLE 20A BREAKER (B) SYSTEM SIZE (DC): 11.4 KW 20A BREAKER (C) 30 MODULES: HANWHA Q.PEAK DUO BLK ML-G9+ 380 30 INVERTERS: ENPHASE Wire Tag Conduit Wire Qty Wire Wire Type Temp. Wire Temp. Conduit Derated Inverter NOC (A) NEC Design Ground Ground Wire IQ7PLUS-72-2-US Gauge Rating Ampacity (A) Derate Fill Derate Ampacity (A) Qty Correction Current (A) Size Type 1 OPEN AIR 3 12 AWG Trunk Cable 90°C 30 0.96 1 28.80 10 1.21 1.25 15.13 12 AWG Trunk Cable 2A ill PVC 2 10 AWG THWN-2 75°C 35 0.96 0.8 26.88 10 1.21 1.25 15A3 08 AWG THWN-2 PROJECT INFORMATION 213 ill PVC 2 10 AWG THWN-2 75°C 35 0.96 0.8 26.88 10 1.21 1.25 1S.13 08 AWG THWN-2 INITIAL DATE: 11/24/2021 DESIGNER: N8 REV: DATE: DESIGNER: 2C 1, PVC 2 10 AWG THWN-2 750C 35 0,96 0.8 26.88 10 1,21 1,25 15.13 08 AWG THWN-2 REV: DATE: DESIGNER: 3 ill PVC 3 + G 06 AWG THWN-2 75°C 65 0.96 1 62A0 30 1.21 1.25 4538 08 AWG THWN-2 THREE LINE DIAGRAM 4 ill PVC 3 06 AWG THWN-2 75°C 65 0. 6 1 62.40 30 1.21 1.25 45,38 THWN-2 NOTE: LETTER "G" IN WIRE QTY TAB STANDS FOR GROUNDING CONDUCTOR. ------ I- PV-3 • ALL • # FOR VOC, VMAX,1 CALCULATED USING THE MANUFACTURED CALCULATOR BASED ON ASHRAE 2% HIGH AND EXTREME MINIMUM TEMPERATURA ENTIRE2THE ARRAY rtr} BONDED ACCORDING TO 690.46 f PARAGRAPH GROUND CARRIED AWAY • WIRE.GROUNDING LUG USING #6 BARE COPPER WIRE OR #8 THWN-2 COPP [c�+'�'~f�^7t�:u[Ks�(Ji�lr"1�:)�iZ►.i�Zr�7 5. ALL CONDUCTORS ARE SIZED BASED ON NEC 2017 ARTICLE 310 6. ALL EQUIPMENT INSTALLED IS RATED AT 75°C 7. INVERTER NOC (NOMINAL OPEN CURRENT) OBTAINED FROM EQUIPMENT DATASHEET 8. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL LOCAL AND NATIONAL CODE REQUIREMENTS. 9. EACH MODULE MUST BE GROUNDED ACCORDING TO USER INSTRUCTIONS 10. ALL EQUIPMENT SHALL BE LISTED PER NEC 690A(B) 11. PER NEC 690.13,690.15, PROVIDE A WARNING SIGN AT ALL LOCATIONS TERMINALS WHERE OF DISCONNECTING MEANS MAY BE ENERGIZED OPEN POSITION> SIGN SHALL,. *WARNING HAZARDELECTRIC SHOCK NOT #TERMINALS EQUIVALENT. 12. PER NEC 705.10, PROVIDE A PERMANENT PLAQUE OR DIRECTORY SHOWING ALL ELECTRIC POWER SOURCES ON THE PREMISES AT SERVICE ENTRANCE. 13. INTERCONNECTION METHOD SHALL COMPLY WITH NEC 705.12 14. AND OPTION FOR A SINGLE CIRCUIT BRANCH TO BE SPLIT INTO TWO SUB -CIRCUIT BRANCHES IS ACCEPTABLE. 15. ALL CONDUCTORS MUST BE COPPER. 16. NEUTRAL AND EQUIPMENT GROUNDING CONDUCTOR BONDED AS PER NEC 250.24(C). 17. EQUIPMENT GROUNDING CONDUCTOR IS CONNECTED TO A GROUNDING ELECTRODE SYSTEM PER 250.54(D). 18. FUSES FOR PV DISCONNECT HAVE AIC RATINGS OF 200KA AC AND 20KA DC. 19. SUPPLY SIDE CONNECTION SHALL BE MADE USING ILSCO INSULATION PIERCING CONNECTORS (IPC). MAKE, MODEL, AND RATING OF INTERCONNECTION CAN BE SEEN ON TABLE 1 BELOW. 20. METHOD OF INTERCONNECTION CAN BE SEEN IN FIGURE 1. 21. UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 22. WORKING CLEARANCES AROUND THE EXISTING AND NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC ARTICLE 110.26. 23. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C)(1) AND ARTICLE 310.8 (D). 24. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C). 25. TOTAL AREA OF ALL CONDUCTORS, SPLICES, AND TAPS INSTALLED AT ANY CROSS SECTION OF THE WIRING DOES NOT EXCEED 75% OF THE CROSS SECTIONAL AREA OF THE SPACE. NEC 312.8(A)(2). 26. SYSTEM IS CONSIDERED AN AC MODULE SYSTEM. NO DC CONDUCTORS ARE PRESENT IN CONDUIT, COMBINER, JUNCTION BOX, DISCONNECT. AND COMPLIES WITH 690.6 - NO DC DISCONNECT AND ASSOCIATED DC LABELING ARE REQUIRED. 27. SYSTEM COMPLIES WITH 690.12 RAPID SHUTDOWN AND ASSOCIATED LABELING AS PER 690.56(C). AC VOLTAGE AND SYSTEM OPERATING CURRENT SHALL BE PROVIDED 690.52. 28. CONDUCTORS IN CONDUIT ARE AC CONDUCTORS BRANCH CIRCUITS AND NOT PV SOURCE CIRCUITS. 690.6. 29. ALL GROUNDING SHALL COMPLY WITH 690.47(A) IN THAT THE AC MODULES WILL COMPLY WITH 250.64. 30. NO TERMINALS SHALL BE ENERGIZED 1N THE OPEN POSITION IN THIS AC MODULE SYSTEM 690.13, 690.15, 690.6. 31. WHERE APPLICABLE: INTERCONNECTION SHALL COMPLY WITH 705.12(A) OR 705.12(B) x 1 RATINGmaims k ► X 1 ADJUST19GURE 1: 1. # OR NUT TO SUITABLE LOCATION BRANCH2. PUT THE ,rt SHEATH FULLY 3. INSERT THE MAIN WIRE, IF THERE ARE # LAYS OF INSULATED LAY IN THE MAIN CABLE, Y CERTAIN INSULATEDLENGTH OF THE FIRST FROM HAND,4. TURN THE NUT BY AND FIX THE CONNECTOR SUITABLE LOCATION. 5. SCREW THE NUT WITH THE SLEEVE rtY s SCREW THE NUT CONTINUALLY THE #► PART IS CRACKED AND DROPPED DOWN momentum SO! -AR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, IN] 08840 (732) 902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307. ORLANDO FL. 32819 :t 1ENPHASE s PROJECT INFORMATION INITIAL DATE: 11/24/2021 1 DESIGNER: NB ALL WARNING SIGNS)OR LABEL(S)SHALL COMPLY WITH NEC ARTICLE 110.21(B).LABEL WARNINGS SHALL ADEQUATELY WARN OF THE HAZARD.LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT,AND LABELS REQUIRED SHALL BE SUITABLE FOR THE ENVIRONMENT. TAG LABEL QUANTITY LOCATION NOTE EXAMPLES momentum 1 AT EVERY SEPARATION BY (p} I ACAUTION I 12 AC CONDUITS ENCLOSURES 1 WALLS! °` `✓ PARTITIONS/CEILINGS!FLOORS AC SOLAR VOLTAGE OR NO MORE THAN 10' x.. PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 325 HIGH STREET,METUCHEN,NJ 08840 (732)902-6224 arm MOMENTUMSOLAR.COM PROFESSIONAL• • "` ' 1 COMBINER BOX 1 AT ANY COMBINER BOX ELECTRICAL SHOCK HAZARD % �` °„� °�°��, TERMINALS ON BOTH LINE AND 1 JUNCTION BOX 1 AT ANY JUNCTION BOX LOAD SIDES MAY BE ENERGIZED iiivi IN THE OPEN POSITION ° ° 3 a w✓ • r. my STATE OF RATED AC OUTPUT CURRENT ELECTRICAL SHOCK H RD �ol TERMINALS ON BOTH LINE AND NOMINAL AOP OPERATING 240 .... LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION C VOLTAGE I OF EACH AT FUSED AC DISCONNECT ACAUTI ON ° 1 AC DISCONNECT COMPLETE VOLTAGE AND (RSD SWITCH) CURRENT VALUES ON DISCONNECT LABEL POWER TO THIS SERVICE IS ALSO SUPPLIED FROM ON-SITE SOLAR GENERATION AC SYSTEM DISCONNECT SOLAR CONTRACTOR CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER:CVCS7036 ,." MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307,ORLANDO FL 32819 F DUAL POWER SUPPLY 1 UTILITY METER CUSTOMER INFORMATION MICHAEL ADWELL-MS90914 SECOND SOURCE IS 1 AT UTILITY METER AND ONE 4622 WISTERIA DR PHOTOVOLTAIC SYSTEM I DIRECTORY PLACARD .,�._ ZEPHYRHILLS,FL 33542 PV 8136965771 STEM INFORMATION SYSTEM SIZE(DC):11.4 KW 30 MODULES:HANWHA Q.PEAK DUO BLK sxrcTCRTO THE•OFF INTERCONNECTION £ FI { ML-G9+380 POSITION TO SHUTDOWN 1 /ter ENTIREPvsvSTEM DUAL POWER SUPPLY POINT 30 INVERTERS: ENPHASE SECOND SOURCE IS _ �� IQ7PLUS 72 2 US PHOTOVOLTAIC SYSTEM r x 1 OF EACH AT BUILDING ° INTERCONNECTION POINT AND ONE DIRECTORY PLACARD 1 BACKFEED PANEL ` PR03ECT INFORMATION POWER SOURCE OUTPUT CONNECTION. "` sesame " r INITIAL DATE: 11/24/2021 DESIGNER:NB DO NOT RELOCATE THIS OVERCURRENT DEVICE REV: DATE: DESIGNER: a P P REV: DATE: DESIGNER: A YI H `` y EQUIPMENT LABELS 4''� f rr�rar`✓"r r�r'��c',%�„f,-�r"�, ��r� 1 AC CURRENT PV MODULES ®BACKFEED Daniel W. Dunzl*k Architect LEED-AP 370 Burnt Hill Rd. Skillman NJ. 08558 908-872-3664 StudioGdesign*comeast.net November 29, 2021 Re: Proposed Photovoltaic Solar Panel Installation Michael Adwell 4622 WISTERIA DR ZEPITVRHILLS, FL 33542 Dear Plan Reviewer: Certification: I have reviewed the engineering testing reports for the racking and attachments to be used on this project and I certify that the products are capable of supporting the code required loads and are suitable for this installation when installed in strict compliance with the manufacturers printed instructions. Regarding the solar panel array installation on the above referenced project please note that an inspection was performed by a representative of the Architect/Engineer of Record, and analysis of the existing structure was conducted. There is adequate structural capacity for the installation of the array with the following recommendations: I. The array will be installed on the existing roof. The roof framing is constructed of 2"x4" wood trusses @24" o.c. spanning 20' 11 " with a top chord length of 21' 10" with intermediate supports at 1/3rd points, making the effective longest span equals 7'6" with 1/2" plywood sheathing. The new array (See Site map by contractor) will add 2.63 Lb. Sf. overall to the roof. The existing structure is sufficient to support the new loads associated with the additional weight & wind resistance. No additional structural support is required for the roof structure, 2. The attachment system shall be secured to the roof and shall be in strict compliance with manufacturers printed instructions. The attachment system shall be UL 1703 approved tested. Provide 6 mil. vapor barrier between dissimilar metals. Provide water tight gasket and sealant at all penetrations. Attachments shall follow panel rows as specified by the system manufacturer's installation manual. The panel angle shall match the roof slope. Reference summary table below: Roof Type: Shingle Fastener Max Spacing (in.) Attachment SLstem: "ROOFTECIVO "RT" Attachment Systems Wind Zone I Wind Zone 2 Wind Zone 3 Fastener Info: min. 5/16" x 4" long stainless -steel lags with a min. 72 72 62 embedment of 3" into the rafters 3, Solar Modules shall be UL-I 703 rated. Refer to manufacturers specifications sheets. 4. Positive drainage of the system shall be so as not to void the existing roof warranty. 5. All aspects of the installation shall comply with the Florida Administrative Code, 2020 Florida Building Code - Residential Seventh Edition, ASCE-7-16, 2020 Florida Building Code — Energy Conservation, Seventh Edition, 2017 National Electric Code, All Local Governing County and Municipal Ordinances adopted by reference or enacted by law. All components used meet the criteria of the Florida Solar Energy Center. 6. Please refer to the attached structural calculations. If you have any questions relating to this matter, please contact me at your earliest convenience! Thank you. 7 Off.t 0 C WFF 'N Daniel W. Dunzik, RA. LEER -AP 0 FL. Lic. No. AR98795 798735 98795 A C Daniel W. Dunzik Architect LEED-AP 370 Burnt Hill Rd. Skillman NJ. 08558 908-872-3664 StudioGdesign*comeast.net November 29, 2021 Gravity Load Calculation Criteria Structural Design Loads per ASCE 7-16 Dead Loads = 10 psf + 2.6 psf (new solar panels) = 12,6 psf Roof Live Load = 20 psf Ground Snow Load/Live Load = 0 psf Wind Load Calculation Criteria Wind Loads per ASCE 7-16, Equation 29.4-7 Using an effective wind area of 10 SE, external pressure coefficient from Figure 3 0,3-A-1 Zone I = -36.5 psf Roof Slope = 17 degrees Roof Mean Height = 15 ft Zone 2 = -47.4 psf Basic Wind Speed = 140 mph Zone 3 = -54.7 psf Exposure = B Per section 2.4.1, ASD combo = D + 0.6W: Zone I = 2.6 psf + 0.6(-36.5 psf) = - 19.3 psf Zone 2 = 2.6 psf + 0.6(-47.4 psf) = -25.8 psf Zone 3 = 2.6 psf + 0.6(-54.7 psf) = -30.2 psf Check Attachment to Wood Truss Use 5/16 dia. Lag screw w/ 3" embedment into 2 in. wide roof rafter Lag Screw Spacing: Lag Screw Tributary Area: Zone I = 72" o.c, max Zone I = (72" o.c. max)^2 l 144 = 36 SF Zone 2 = 72" o.c. max Zone 2 = (72" o.c. max)/12 1144 = 36 SF Zone 3 = 62" o.c, max Zone 3 = (62" o.c. max)/2 l 144 = 26.69 SF Lag Screw Forces: Zone I = 19.3 psf x 36 SF = 695 lb < W', OK Zone 2 = 25.8 psf x 36 SF = 929 lb < W', OK Zone 3 = 30.2 psf x 26,69 SF = 806 lb < W', OK W = 2661b/in (Table 12.2A, 2015 NDS) Cd = 1.6 (Table 2.3.2, 2015 NDS) Ct = I (Table 23.3, 2015 NDS) W'= W x embed x Cd x Ct W'= 266 lb/in x 3 in. xL6 x I = 1276.8 lb powered by BREAKING THE 20% EFFICIENCY BARRIER Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20,6%. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low -light and temperature behavior. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology, Anti PID Technology', Hot -Spot Protect and Traceable Quality Tra,QTm. EXTREME WEATHER RATING High-tech aluminum alloy frame, certified for high snow (6000Pa) and wind loads (4000Pa). E, A RELIABLE INVESTMENT 'El; Inclusive 25-year product warranty and 25-year linear performance warranty2. STATE OF THE ART MODULE TECHNOLOGY Q.ANTUM DUO combines cutting edge cell separation C= and innovative 12-busbar design with Q.ANTUM Technology, APT test conditions according to IEC/TS 62804-1:2015, method 6 (-1500V, 168h) See date sheet on rear for further Information. THE IDEAL SOLUTION FOR: 69 Rooftop arrays on resldentW buildings Engineered in Germany OC"MELLS MECHANICAL SPECIFICATION nrm',.. 72.4in x 40.6in x 1.26in (including frame) (1840mm x 1030mm x 32mm) 4301bs(195kg) 0111n (2.8 mm) thermally pre stressed glass with anti reflection technology ......... .. ._ ., ,3.... �•, <- Composite film -- -------------------- ...-... _.._. .... .,_....__ ........_ ..v__.-___..-_. ... ._..._..... .............. ...... Black anodized aluminum ............ -._-._._ ,_�..._ _. -...., _.........,. _._ . .... ......... ..... ..__.. ._.. 6 x 22 monocrystall(ne Q.ANTUM safer half cells u v' _, ....m .. ___._ 209-3.98inx126-236inx0.59 071in (53-101mm x 32-60mm x 15-18mm), IP67 with bypass diodes _... .. _ . 4mm2 Solar cable; (+) a472in (1200mm), (-) �:472in (1200mm) ....... . . ....... .... ---- ............... .. ......_ .. ........... ..... .,... . .............>... �. <> Staubll MC4 IP68 72.4-(1840 mm) 16.A (ai6 mm) 42.4"(.as-) -. ®. 47z^(S200mm> , 4xt ...g points a 03s^(4amm) �� Frame aa.s•(sslmmi i [� 4oa-poaomm) Labs' -❑ --�Ytn,-4x^z-az-oo mmy Bx Dm,aege Mies 4 x Mpufllnp sMts (PETAIL A) OF a2mm) DETAILA 0.63"(18 mm}T Pea"(24,5-) ��I-L 0.2a"Ie.fi mm) ELECTRICAL CHARACTERISTICS POWER CLASS .. 365 374 -__........ 375 ............._._...... ............ 380 ,, ,._..., ,__ .. ..,....__,.. 385 .......... 1 #iu.'r <...t ,,, rvt.a� s iv,.i ...... t t . .. _. ._. , .- f, ...NI P z; ------- , ,,.,, _.._..... ._..,., , _...... ......... pmpp _. ... . .. _.. _.. . _, ..., _.. _ [W] , ..... .....,,.. _... , 365 _.,_. , _ .,, . .....,_ , .. _ 370 _... _ ..... _ 375 , _. _ _ ... _........ 380 ..... . ................. 385 ------- hao',. cw ur �. so [A] 10.40 10,44 10.47 10.50 10.53 Open , „ u, V , ,m _....----- - __----- -- ..___..--- V .-__ [V] ---_..... . -- 44,93 __ w 44.97 _,._ ..... ... 45.01 _ __,_.._.. 45.04 ...... 45.08 _-_.._.._ ,�e st riE=L' . ____ M,r __-_. " _"_.r. [A] _...... 9.87 ___.- .. ..__._. 9.92 ... .,,.____ _.._..._._. 9.98 _..--- ..__..__ 10.04 __.... 1010 _- ., toPa ,,1IP, -,-- ...,-....--- Vmn' _ -. [V] _..- 3699 _. 37.28 _„._....___ ... 37.57 _------- 37.85 .-���.. 38.13-- q [%] _. a19.3 _. _ - >_195 _ _.._ _ >19.8 _.-.. _.. __,_,..__ _.._. 220.1 . �20.3 ._. .,. R<.a .'r. R,frC, MOtt{., A 0 R 1,AL0> R.:(UC .O� 11 }{13, .`ct0 ---- ,_. __...._ P------ --- .. _ ._..,. . , __.. _.... _�.._.. _ ,.,... ....... , ..,. , .__ ........_.__ , , -_._. .. , _._., .._, . _ . _ ., _ ..._......_.... _ �_.. .. „___ „.....,_..., -_.. .....__. ,.. SnD-, , ckwCs„ n', Isc [A] 8,38 8.41 8.43 8.46 8.48 cull, l, 1rc ullo( Voc IV] 42,37 42.41 42.44 42,48 42.51 (>c a MPP _ IMpr . [A] 7.76 _ 7.81 . -.. 786 7,91 _.,,.. 7.96 Volta" v, �' _ .__.......... .,.... _... ..._ VMaF r. _ [V] .. _ . .., ._.._... 35.23 .. ...-_, .. _ m 35.48 _ _. ,.._,. _. 35.72 . _,.__ ...... ._ _... ..w........... 35.96 ... ....... ... ...... -------- 36.20 _.... .. _.._.. Measurement tolerances P, t3%; Isc, Voc t5 % at STC.1000 W/m2, 25t2°C, AM 1.5 according to IEC 60904-3. 2800W/m2, NMOT, spectrum AM 1.5 .....-,�....__ _. ......--- --- .._....,,....._,.__...__.......4..,.._._...._._._.._....®.�..�_ Q CELLS PERFORMANCE WARRANTY _.-.._...®._ _.,_...._.. .. ...._.._ .......__... ._.,....,. PERFORMANCE AT LOW IRRADIANCE ...__.._.m. ,------..---- ._....------_..�-- At least 98% of nominal power during first year. Thereafter max. 0.5% degradation per year. At least 93.5% of nominal power up to 10 years. At least 86%of nominal power up to 25 years. All data within measurement toleranc- es. Full warranties in accordance with the warranty terms of the Q CELLS sales organisation of your respective country. ,Sip f - _-_____,..______ __ ----i I too I I 40 "0 400 800 000 fl000 Typical module performance under low irradiance conditions in comparison to STC conditions (25 °C,1000 W/m2) TEMPERATURE COEFFICIENTS _ . , _... .. -- _ _.. _. _ _...... _. „ _ .. ---- ,.._ac.er l.;n;._�,; ,if:vc,.r, ; a" ..-..., .,.,. , .. ...v._ -.0._2.7c [%/Kj +004 l(%/Kj _.,._.. .----- [%/K] _0,35 No nw 1f.F 0,,„t ;� NMOT [eF] 109 t5.4(43 t 3°C._)Y PROPERTIES FOR SYSTEM DESIGN [V] 1000 (IEC)/1000 (UL) rt . ,ww r: ,.,- ca! on Class II Slx'mu ,.>�_,_.l">; a b'q [ADC] 20 ;:) ,„bags,, „v iA,U„ o TYPE P.. 1 a?a 4 es'pnr '... d. =. nh I Pull l [Ibs/ft2] ..84 (4000 Pa)/55 (2660 Pa) _ ,.... ... ... „_.... _. -40°F up to +185°F .......... _____. _______. _.____ _ _ (, (-40°Cupto+85eC) Nia, , oaa = r ,�h [Ibs/ft2] 125 (6000Pa)/84 (4000Pa) _.. _--__ .. _.. .,.., _�... 'See Installation Manual __ ... _. QUALIFICATIONS AND CERTIFICATES PACKAGING AND TRANSPORT INFORMATION UL 61730 CE-compliant. 68 IEC 61215:2016 � IF . {) aWNG' IEC 61730:2016 ® .- .,..._ _ .. _.,�.. ...__ _-.._ ..-._...... ®. �........,,. ..._.... Us. Patent No.9,893.2>5 r©vn ,4am 74.4in 42.51n 47.6in 1458lbs 28 24 32 (solar Celts) C US k,t c, 1890mm 1080mm 1208mm 661kg pallets pallets modules ca,,,rlae 81)a0 @ ti1rt 22P ]] Nate: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Hanwhe Q CELLS Amerloa Inc. 400 Spectrum Center Drive, Suite 1400. Irvine, CA 92618, USA I TEL 1949 748 59 96 1 EMAIL inqulryQus.q-celis.com I WEB www.q-cells.us Sheet Enphase Micrainverters E_nn1l,niva,''S., E" 1-41 fIN olf I rN, —F utC.'tI re, an c1l e, n ,, e tit i 'Icroi Q To learn more about Enphase offerings, visit enphase.com The high-powered smart grid -ready and Erqlhase, IQ 7,+, Micro.. dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase 10 System, the 10 7 and IQ 7+ Microinverters integrate with the Enphase ta Bvfh2se Enlighterl'o monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and enabling Enphase to provide an industry -leading warranty of up to 25 years, Easy to Install - Lightweight and simple More then a million hours of testing Class lidouble-insulated enclosure UL listed unman= frequency ride -through requirements Remotely updates to respond to changing grid requirements Configumble for varying grid profiles Meets CA Rule 21 (UL 1741-SA) MEE27-M - -%'ENPHASE N�10 ','Q T& Wicroinve,�-"�Ilers -,�nphlase 10 7 z,,,,,,,nd U S" �"07PWS-72-24,*,S �WPLUS-72-0-,XJS ets ,I,, "d s, m"i., .,' MB W 440 W,�, synew "W"(WONS nro 504YR aw 72-avT DO -semk, Dc mmmy"', 7 v, 37 't V "e v"JAW wm"a mul", 22111 081, ?7 v 10 DIG so" tnonlunaeo mum No KW&"VW on xWevul, bi OUTPUT DATa JQ, 15C va AF VA vP 190 V" :W 0141 211164 V '83229" v"Ww- mmmm. any 10mv Q A "An v; is A038 An '21 A 145 V! W A 1208 0 Exwqded Yrummov -wcn� 'v lao, kwv� a y"r TO haammum umn ow 25 A A C ywyn now, 15 q a va, 'c" 68 VAC Al'txw' A VON usomeen nwn"""" A vulwo ovivy svmvi�:� ''a AWM ham WWWWW n 7 LeMag . W ingyng C - moms 01 wgorl"';' Peak CEO of5conn, 9"T Q7 v A 90, W I a 1EG weavImM d5won, Q10%; q72% Q" 1 Do e, WG"AHWAL DATA r)lv"O- "O-'sA�ra f"'I'Mq, '."""'en zlnn"t"r us'e" "m R 62109 TU117ONKEWSK "CC Pao 4 Claw 9 ;CES1033 Coss,",", QANSS&W VIM Wil X Mo mmum 4 A -iced W PY "Wo "M Dmn FWMMvM my commms an WCAW4 yo W&W 17 ow1bon QW2 srd = WGIN We 6440 Repo ShuMown of FV System, Mr AC 'gPl J""(: room WWWW" ro.WMWM S mmmums, 'o hanxd'e, figzzq-rrZen" "I'suLmonim". "'Pat"biftly, W, he 1"myc hyc-N r"Yna? at owma by TE u5m, n M'S W 7 &W so wu M"Ma vs j, , mom W v- Nwayl my c, 1 c,..as I,, V v I I 10 0 2MB 50me Energy M dots or Nook aed are the property of Fnphase hery. hc, 2MT0124 a A Enphase IQ Combiner 3 (X-1Q-AM1-240-3) LISTED To learn rnore aboult Enphase offerings, visil enphase,corn '-,e Enphase IQ Combiner 3" ,A/ th Enc),nase !Q J'y dates .terconiec(,r eictuipi,T)ent, into a single enclosure and reamt hnes and slora-e hlnstallarions b,,,, I -�-wrl, a consistteW, pn ea! solut!or fol -es'ldential arx)i caluors, i� offerS L-11f) tCfOLF DOle P ­ t n 1,6"JR ser, 'snd Fato '_)Uswit r assernn!y, Smart Includes IQ Envoy for communication and control Flexible networking supports Wi-Fi, Ethernet, or cellular Optional AC receptacle available for PLC bridge Provides production metering and optional consumption monitoring Reduced size from previous combiner stud mounting Supports back and side conduit an" Vp to four 2-p51,-,;, braneh eirewits for 240 VAC plug-in breakers (not included) 80 A total PV or storage branch circuits Durable NRTL-certifiedNEMA type 3R enclosure Five-year warranty UL listed ENPHASE Enphase IQ Combiner 3 (',%Dr-L NUMBER M WAM. 3 kmomhmy:� Q CwAmw 3 mA .now? 4 Emp"prtntec cwcM boa d Per mgwed mynue Vne PV pusdumn mocmg (ANSI C12,2,0 and opti,.nal" consuamt;on monitaring (+/- 2,5"h) ACCESSORIES and REPLACEMENT PARTS Ur, ase WbHe Gen ne," CELLMODEN503 W! 11yew dMa p1ml P%g and pWy mdusumi gmche cekdarnocern mth date plan for wster-n's up to 60 CELLMODEW01 (K ' Swear "M oWn) in the US, Canada fAexir,,.,, Puerto Rico, and the US Vi�wn GEU UODEM M! AG bawa UE W 5 yew cm pWQ whem Merms adeq,mha wMW servim m Me muHatron ami � CorsumnUop KlomormV CT COMOAK1,11, 2,51os cumq Bropers SUUjrl.,'Falon BR,2110, BR2,11s, BR220, BR230. HH240, BR250 and HR250 cocurt bwakers BRK13A 2 240 pc)k-,, IDA, R— C R�, IC BRORAQ4� " ,"ImrW hreaser, 2, pcCe, 15A, Eaton BR215, WIOA-224C Ckcuq Waken 2 oov, 20A, Won BR220 EPI-C-01, Own Wn munnom"MWIAM bAp OWO WW""2 XA PWGUO to", power m-Carrier m !Q Con-ftnsr 3 (rer-apred" for FIDLO-OZI�, XATNV-PCBW1 ReMwern"t T Frmy pmnm comM howd WCM Im Cornhnu 3 ELECTRICAL SPA CIFICATMNS q CoMmucus dW,,,,, Svs"'("w VA�o""'g�� W040 VAa 60 HI 13 BR series bisb, aling !nA o`,ax con it (-€!,rett?ralng (m,ttori, to grit`" tT5 A May, fuse-'circwt rntinq imitouT) 9 0 "', Bronm mcuRs soor anc,'orewage Up to few Imm Won BR senes WrIbuted Gmerahan (MY bm"ps omy mot uslue,10 , x, conflnucus crirrent,ot�ng (ineutf PV, ? A May, 1W1brWon cWUq Dreaker lohng (mow) 80A of dn"butec genem= 190A wrth Q hnvcw breaor mckWnJ Orou"hon Mmmg C NO A ..WO ccre womsWked ea ,yn'ed To Q Eiwny MECHANICAL DATA Dirvensms (WxHxW 490 x 17 n if, an (19 5"x 14 75"x 6 634 Heqht s 21 06r53 5 crns,i�,h mnwhm bmlws) 7 5 4 06 5 W 20, C to -46, C 5400 U) (,51 M C M T", 'c N o T ! ro i ('0 fl V e C t I (, ')It P, a I y, h e ! c Outckmv-, NPT' -ce, fiffpxn, NE1,1A yp 3R,00!v4'23rbonatc, consluucdssr, W10 SRSs 2nAMjQAbm"ermMK 6VABrea 0rhmwMm"v AWWAW mccume wwaemmM Mr urm"W; vmq� ANud,, yn 2000 melms (Q560 W! INTERNET CONNECTION OPTMNS WMquawd WVF- R02 ilmqir, [thems Wma SK 3 CwW or W 0 Wis Laime We fnc,Undwcc� cepwa, ommony ckum 00 ""M - 01", Nly") c r C E'LLM ODEM-93 w CELLMODEM-Ml �4(3 basedL-FE M) ,po,, inc.!udec` CONIPLIANCE =mAncy cmdymer J L 17,11 CAWWA CA 7 No M71 47 OFR, Pm! 1� Class I WS JN PmUawmwWmg ANS! 012 21 accumco, dass a5 1PV procuctcn7 Anvioncy 10 Envcry A bMW � TAWSA K 2 No TMO 1 , fwnsumnton Inmoomc; 0 K"aw Tor"e, smw-l� To leam more about Enphase offerings, visiz, enphase,com 0 2MB Enpose ae, M VVM MWWM M nkmMs or )rands in tls document arc rogsTred by %r osmmeowner 2780113 O=ENPHASE %W.100 m EX Universal Clamping / Slide In Mounting One Step Leveling / Integrated Flexible Flashing • • Aft ♦ 0 �' Z 7 l•^, �t '� .,tie," \Z a1.' }. �... 1?.: �1'+'»,�,,,,=x\ .\ t< ,}; , .. 4. '?•, �.:t. '�'„ \,t .tR.\,� ,``e4�' a?,. t'z'Z .,.ti,a .. „za .,.. . ti..?•, 1 �.`< . \r.'�.y �.�. t �. . '\. :₹.. a i}. S'xL�}.,t.. �. ?,<.` , \ ?� .1., 1, h. < .F`?, ,a�t t,` },,..�;. , .v. .'.~•a\: ,.l ,czl + lx,�,, {�, S •.Sal. .r\ F ,li\a� 2..\�. ., ,.l r l.: `ti. S.�.x ., }s i "`v, ,1 .,. < \ 'a1ll•v.� { �, l\. `l, ',2.. 7 , t,.•.e ,. ., v .L,.}. ? �.r. , ,'t ', 4 �,r �., >.'7..4, .,>t .L ,1.,\, ,.,;.x, `•$ t .�.. .� ,tZ, ..;?r ,.'1 a.�i ~,� Sot .l z 4,1. b,.,«< ? 1, =`.t<. .\..r i R �* r , ',. • � � 'v o,.«,. ,r .?;'., l.. ..\.. t:1 x, e„v , 1t{, ,. ,\. �,,.4.� 4 }.,, \ £4 � «. F i,�»`J. 1»Lzt ,\\•,.�.? 2 12 �• 1ie � S. `,. ,4- .).S \74. ,1 `\ .�\. �: � •,x?:= \ .."i\. \L1 \ `\\l,\.`.�\\ 2.. c,i. .sL. .., ., ``*,L k -r r.' ..,. lr„ t :. t.: i, •.. t,,.' a.. oi, >,. .).,, � ,., x, l ,'e., }r ..,.rY ..n,. .\..t,..�.,a�4. .{t?*?v .c .,..v 1'F v.. .,. .1'' < 1, `, '• ., < �< a .l ,. „r. 7 , ., ,>< ?.}5 q., .., \.t. , �a1�, <Ss�1 ,... ,z \,;. i,4S -. «. a. \:. ;{} 1�a 13 Utp«,a4,. � t`ti L,\7,,,, .,�'",� ��� e\ .,1`4 F �. rF h?\t i.Llt,•a,,, F., t r{' .�, 1{?t,,ly�==i1 \��i,.,�� r{S.-�?>S t ),�L1 <i,,.r�C. e�c:,,�`z₹�tt� �\»,SN£'1�?Cir..` ". =}�»`,\�r�, `2 t1\a`„�L„n 1,₹4,, }i `� i`,` '��a?r '{'� �1`k r�� ,xz'4'y��'�,�= is; �•� \x?�?71��:.'ty .13L:\��z Fsh>. > { �,,a c ��a�o< ,h�A�S 4v{ ,l h;, v�` F .I 4 1»•� Lt t�� F 1FF,, r « l S v}r. • S wr " w • • i •` • • 5* • • A1* i,w II - • i• t • 6: w ti � 7?jt 2 v t Jry hl` a t I.. Is .. S 7=. .L\\, ,. } „": <"• t?. :1 .vS ., U ., } S .er\: , 4x a 34 S 1 xv...,u\r ?fit 1 rl }, �. t. >r � >ti \ \•{e<: <, li Lz<,x ,� ,..«\ ;`4a =•t. , z �.. ..4 tt\. , z `� z4.��te`tt \ .\ �\ .� 1.u. 1l xaxt ti\ .\S\. \..\'zz .• ,,,,. L,. xt� L a. 7\.,...j\..\ ,} , c:: ... \.. :1 L l z �� (Fx. I `,. 1. 1`a a \1 ,.� ,�,.X11.F : \.... 7 t, aa, L,, \\ ,L �, a�i 4�,,, � .�a �4��<\ .•; 7 � �\..\ L � � , 4 L,• to 71 <, a,; � � tr. \k�,�\.. }„ F'F- :, 4?,\\� z .}.`„ <�L7`"•alt.h;, r�«171.t.,�1. ,..,. zt '' ti '+ �',` n4... 1 a.,?4 ,. }�, ..£: � <. .,,, a4,€ ;v tx C? .�,:,�.t to »��:�1 \ �, ��? .Ea1 lna <t...a,L { .?x.ti :\751 1;: ,�tt .v: :•„ 1, rat„ r �`\,r,, h1t1 1'. vv t z z. ?1 .r. \ t ,xt \ r ... . .t., •,.,,, L .,.... L.,,, ..\ �:..< ?aa ..., x4. b. k1 .tl.. , ,,.:,,.,, 7�\. ,..� .• ,v: s,' � ,,xL ,_ .� �.t r..L3 ,.U: .,, \., o.. ,L,.,. y.,», «m_<�. .,. ,L ..tz << 41a .,\., ,a4.�.. ,. \ • ,:, ,, « v, .,..r, �=T..a. <F.. \ ,.�,{.. ..a :�1 .\ ,. �I,SF 1,;.a,\�}.. '� r?± c,�.vn r: Lz.�. 1..:1,\ � s�,,.,Y. ~~ •a tri, S. � {'{,1. 7. {i \.Y,vF.,..,;}. 1. �,Ly„ yt_ 1 �R .,.R5 1.,�. {L, ,h.\\� `§`\, `rc..>k�...`?:<>}.? 5..,,.L.��`�r. .\�r. �C£\, '7< „\ \., S.t�. i'. ..�r 14>>av�{,� l,.v.r. L?.`}•\, `4'la{.. '7,L,.,.2, 6ZOLL Xj'uojsnOH 4@,3-JIS AIJEODN ILZ -Dul'swalsAS ainsol3u3 j@ilDuAA 10 UOISIAIP e :UO40allOS :Aq pajnl:)ejnueA 1199MY ELORMI UMIJ sl�= 1 0 iiun Bul.14sei-A xoj3 uoipunr jejoS dolloolg www.soltection,com Soltection RJ-1 Installation Manual Page 2 i �� A ;n A L t '^17 x. a r C U Y t IMPORTANT SAFETY INSTRUCTIONS. ....... --- .......... ......... ...... ............ 4 SAFETY WARNINGSCAUTIONS .....,..,...«.................. ...............................>,.,......... ................,.....,....,...,<«........... ..4 ELECTRICAL PRECAUTIONS...,,,.......... ... ......<.............,....,....,..,,............,......,.,,..,.,..,.,., 5 MECHANICAL 1 TII,......>,.,>..............<.............,..._.,..,,....,....,,..., ...... 5 PRODUCT INFORMATION ....................................... 6 OVERVIEW. ... ...... ..... - ...... 6 PREP& PLACEMENT.......,,,,..........,.........<...,...........,...>,..,.........,..........>..,,.,..............<.... 7 REQUIREDTL...... .................................................<...,.,......,,.,........,..,..........,.,......,,,........ 7 PRODU T LAT'.....<....................................................................................................................>.......,,.,.,,,.,.. y SPECIFICATIONS>...............................................................................................«..,.,...,......,...«....>....<.....,,.,.<..,,. 1� MECHANICAU ELECTRICAL .........................«<.......,.,..........,,....,....,.,>.,..,...............,,.................,....,<..,,.,...,.»,..,....... 31 TORQUE itN...............................................................................<..«......,..,.......,,..,..,,,.....,.,....,«,...,.,.,.<.,..,.......,. zi WARRANTIES: Seller warrants to Buyer that products and any services furnished hereunder will be free from defects in material, workmanship and title and will be of the kind and quality specified in Seller's written quotation. The foregoing shall apply only to failures to meet said warranties (excluding any defects in title which appear within two years from the date of shipment hereunder. The conditions of any tests shall be mutually agreed upon and Seller shall be notified of, and may be represented at, all tests that may be made. The warranties and remedies set forth herein are conditioned upon (a) proper storage, installation„ use and maintenance, and conformance with any applicable recommendations of Seller and (b) Buyer promptly notifying Seller of any defects and, if required, promptly making the product available for correction. If any product of service fails to meet the foregoing warranties (except title, Seller shall thereupon correct any such failure either at its option, (i) by repairing any defective or damaged part or parts of the products„ or (ii) by making mailable, F0.13. Seller's plant or other point of shipment, any necessary repaired or replacement parts. Where a failure cannot be corrected by Seller's reasonable efforts, the parties will negotiate an equitable adjustment in price. The preceding paragraph sets forth the exclusive remedies for claims (except as to title) based on defect in or failure of products or services, whether the claim is in contract, indemnity, warranty, tort (including Sellers negligence), strict liability or otherwise and however instituted, Upon the expiration of the warranty period, all such liability shall terminate and Buyer shall have a reasonable time, within thirty days after the warranty period, to give written notice of any defects which appeared during the warranty period. Except as set forth in Article 2, "Patents," the foregoing warranties are exclusive and in lieu of all ether warranties„ whether written, oral, implied or statutory. NO IMPLIED STATUTORY WARRANTY OF MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE SMALL APPLY. Seller does not warrant any products or services of Gathers which Buyer has designated. www.soltect€on.com Soltection R1-1 Installation Manual page 3 NOTE: S"E THESE INSTRUCTIONS This manual contains important instructions that shall be followed during installation and maintenance of the Soltection RJ-1 rooftop junction box with flashing. LETHAL VOLTAGES ARE PRESENT DURING THE INSTALLATION, OPERATION AND SERVICE OF THIS EQUIPMENT. PROPER PRECAUTIONS MUST BE TAKEN AT ALL TIMES TO ENSURE THE SAFETY OF THE SERVICE PERSONNEL. A, 11 "I'll" I gay"WIRM a11&1;X--*1D*n' I • Only qualified personnel or licensed electricians should install this product and the instructions herein are provided for those individual(s) only. • To reduce the risk of electric shock, injury, or death, all electrical wiring and connections must be performed by qualified personnel. • Lethal voltages are present during the installation, operation, and servicing of this equipment. Proper precautions must be taken at all times to ensure the safety of the service personnel. • Follow state and federal Occupational Safety and Health Administration (OSHA) guidelines and regulations when installing this product. Utilize proper Personal Protective Equipment (PPE) as required per national and local regulations as well as for installation best practices. Install this apparatus in accordance with ANSI/NFPA 70, National Electrical Code (NEC). Follow all national or local electrical codes. Install, operate, and use this product in a manner consistent with the instructions provided. Failure to follow the procedures indicated may result in roof leaks, property damage, or consequential damage. www.soltection.com Soltection RJ-1 Installation Manual Page 4 * Ensure all electrical conductors are at zero voltage potential before installing or servicing this unit. * Never break contact on a circuit without using the appropriate disconnect device. * Follow established lookout and tagout procedures for all electrical conductors prior to servicing, * Beware of power lines in the vicinity of the roof, where Inadvertent contact may result In electrocution, personal injury, or death, * When disconnecting source or supply circuits, provide sufficient time as stated in the power electronics manufacturers instruction manual in order to ensure discharge of all conductors in the circuit. * Always verify the Integrity and proper installation of the electrical components prior to energizing electrical circuits. Non-metallic enclosures do not provide grounding means between conduit connections. The use grounding hubs and jumper wires are required, i Xy When drilling into an attic space, ensure that electrical wires, mechanical obstructions, or potential electrical hazards are removed from the vicinity and direction of the drill. Do not install if the roof is wet, frosted, or covered by ice or snow. If any part of this product becomes damaged, remove and destroy the entirety of the unit. Failure to do so may result in fire, property damage, personal injury, electrocution, or death Do not use the product to anchor fall protecti equipment, i www.soltection.com Soltection RJ-1 Installation Manual Page 5 The Soltection RJ-1 Residential Rooftop Junction Box is a flashed roof penetration designed to prote electrical conductors entering the rooftop/affic. It is made of a high -strength UV -resistant and U1 stabilized polymeric material. The RJ-1 enclosures comes fully equipped with a slotted DIN rail mounted inside the enclosure design for mounting of DIN rail accessories, such as terminal blocks. i A four position ground bar is also provided as a means to form a bond between the solar arra:mount on the roof and the building, CORNER SCREWS AFFIXING DIN RAII www.soltection.com Soltection RJ-1 Installation Manual Page 6 ShingleRipper Lumber Crayon Hole Sawor Spade . Roofing Identify the . flashing on the roof as shown. The product may be mounted beneath the array or adjacent to the array, www.soltection.com t Soltectl R1«1 Installation Handal A IN00,00511mt where you Wit drift in the 116: «,� tttP4 www.soltection,com Softection RJ-1 Installation Manual Page 8 www.soltection.com Soltection RJ-1 Installation Manual Page 9 • Populate the RJA unit using the appropriate -wire cohqootbrs� terminal blodki�-or other necessary components. • Ensure that!!* components Initalled4re rated for and �ate suIWbI0bf1h64it6rfdsd purpose. • TheAJ-1 ' unitis provide&Wth' multiple standoffs which can accommodate accessories to be mounted. www.soltection.com Soltection RJA Installation Manual Page 11 d""'v © • Product Certifications: UL508A • Enclosure Rating: Type 4X • Attic Conduit Pass Through Connector Size Range: 1/2" — I Max. Side Wall Conduit Size: 1" Maximum Current: N/A Maximum Voltage: WA Ambient Operating Temperature: -35C to 75C i Ti =htenlnTor ue lb -in, www.soltection.com Soltection RJ-1 Installation Manual �11)- vVnckier 271 McCarty Street Houston, TX 77029 1-866-227-0577