HomeMy WebLinkAbout22-3438City of Zephyrhills
777
\� 7� ,\\`fi R 2 \
`f\�
5335 Eighth Street
�V A`~.. y v\vl)r 3
yvv v ���
Zephyrhills, FL 33542
BNR-003438-2022
Phone: (813) 780-0020
Fax: (813) 780-0021
Issue Date: o2ro8/2022
�1sI"s J Jt l ,IA\tatA'
\
w i �. \ a1\,. J .`N
,,
Ju:
,'t
7316 Sail Clover Ln 35 25 21 0180 Q1300 0180
Name: D R HORTON Permit Type: Building New (Residential) Contractor: DR HORTON
Class of Work: SFR Construct
Address: 12602 Telecom Dr Building Valuation: $104,000.00
TAMPA, FL 33637 Electrical Valuation: $6,800.00
Phone: (813) 549-1968 Mechanical Valuation: $5,000.00 ° �V
Plumbing Valuation: $7,200.00
Total Valuation: $123,000.00
Total Fees: $18,378.25
t rR.
Amount Paid: $18,378.25 ;, .» v
Date Paid: 2/8/2022
1t.�vy \:2\i>. 5:, 112\�AP`.t.t.\M,..,..:t::
A7,777
,t.
.A. v \v
,.t
t A \A\sz\i
CONSTRUCT SINGLE FAMILY 2,011 SQ FT ZL
Transportation Impact Fee $3,595.68 Public Safety Impact Fee -Police $254,00
Plumbing Permit Fee $76.00 Building Plan Review Fee $280.00
Sewer Connection Residential Fee $2,090.00 Building Permit Fee $560.00
Mechanical Permit Fee $65.00 Electrical Plan Review Fee $37.00
Transportation Impact Fee - City $36.32 Mechanical Plan Review Fee $32.50
Address Fee $30.00 Water Connection Residential Fee $1,010,00
Park Impact Fee - Single Family/Townhome $769.56 SIF 1 percent Fee $83.28
Public Safety Impact Fee -Admin $26.35 Electrical Permit Fee $74.00
Irrigation 3/4 Meter (Cale) $473.78 School Impact Fee - Single Family $8,328.00
Driveway Fee $45.00 3/4 Water Meter Fee (Cale) $473.78
Plumbing Plan Review Fee $38.00
EINSPECTI FEES: (c) With respect to Reinspection fees will comply with Florida Statute .0(2)(c) the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection, whichever is greater, for each subsequent reinspection.
Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies,
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing, consult with your lender or an attorney
before recording your notice of commencement."
Complete.• .► fee Must Accompany Application.
accordance with City Codes and Ordinances. O OCCUPANCY BEFOREC.O.
A
CONTRACTOR SIGNATURE
I r
PE f IT OFFICEU
ITHOUT APPROVED INSPECTION
PASCO COUNTY, FLORIDA
Permit No.
Date Permitiad
iulilder Name/Owner Name _L_LdLControl
County Parcel No. ubl)lv:
Address/Location
ClassificationlType of Use
TRANSPORTATION IMPACT FEE sits: Sq,Fttrite _2—
Exempt' D Yea 0 No How Determined
Impact Fee Amount AL Zone No. TAZ:
Account (066) Single -Family Detached House Amount s
(057) Mobile Home
(058) Other Residential
123) Collection Fee
Exempt yes No How Determined
PARKS AND CR ION FEE -
Land Account Land Credit Land Total
Recreation Account Recreation Credit - Recreation Total
Zone TOTAL AMOUNT
Exempt C]Yos []No How Determined
LIBRARY FEE
Land Account Land Credit Land Total
Facility Account _ Facility Credit Facility Total
Exempt E] Yes [3 No How Determined Total Amount
R9SOURCEFEE ERLI
TOTAL AMOUNT
Prepared By �,4_ Chocked By
NO CERTIFICATE OF OCCUAANCY WILL BE ISSUED OR FINAL INSPECTION
PERFORMED UNTIL THE TOTAL AMOQNTS LISTED HAVE
BNERPAIDAND
RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY
Acknowledgement below does not imply acceptance of concurrence, but simply receipt ofa copy of We form, placft
the buDdft permit to on notice of this assessment and tim conditions of payment for same.
RECEIVED BY
RECEIPT NO. DATE BY
813-780-0020 City of Zephyrhills Permit Application Fax-813-730-0021
Building Department
Date Received MMoyes@drhorton.cI -sit om
Phone Contact for Permitting
AMR a A
Owner's Name DR Horton Inc Owner Phone Number 813-549-1968
Owner's Address 12602 Telecom ®rive; Tampa, FL 33637 Owner Phone Number
Fee Simple Titleholder Name SamE� Owner Phone Number
Fee Simple Titleholder Address
wM # g
JOB ADDRESS }� t e C7.`.M i LOT # ! C Lai
SUBDIVISION Abbott Park PARCEL ID# 3 0l 0 �
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED H
NEW CONSTR 8 ADD/ALT C� SIGN 0 DEMOLISH
INSTALL REPAIR
PROPOSED USE SFR COMM OTHER
TYPE OF CONSTRUCTION BLOCK FRAME STEEL
DESCRIPTION OF WORK New Single Family Residence Beds v Baths, 2 Story Hom
BUILDING SIZE SQ FOOTAGE `� HEIGHT
®BUILDING $� VALUATION OF TOTAL CONSTRUCTION
=ELECTRICAL $ AMP SERVICE PROGRESS ENERGY W.R.E.C.
=PLUMBING $
=MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION .P
t
i
=GAS ROOFING SPECIALTY OTHER
FINISHED FLOOR ELEVATIONS 2 C FLOOD ZONE AREA =YES NO
BUILDER COMPANY EAR Horton, Inc
SIGNATURE REGISTERED YIN FEE CURREN Y ( N
Address 12602 Telecom Drive; Tampa, FL 33637 License # CBC039062
ELECTRICIAN COMPANY Strada Electric
SIGNATURE _ REGISTERED LY / N FEE CURREN Y / N
Address 3400 St Johns Pkwy; Sanford, FL 32771 License # EC13003715
PLUMBER yyy COMPANY Northwest Plumbing
SIGNATURE REGISTERED Y / N FEE CURREN Y / N
Address
6310 Mabelton PAY, St 1000; Mableton, GA 30126 License # CFC1427137
I.
MECHANICAL COMPANY Progressive Air Systems
SIGNATURE REGISTERED Y / N FEE,CURREN
Address 7130 Meighan Ct; New Port Richey, FL 34652 License # CAC033669�
OTHER COMPANY Brad McDonald Roofing
SIGNATURE REGISTERED Y / N FEE CURREN Y / N
7143 SR 54; New ort Richey, FL 34653 CC1325833�
Address License #
RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction,
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects
.COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction.
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance
SIGN PERMIT Attach (2) sets of Engineered Plans.
****PROPERTY SURVEY required for all NEW construction. '
Directions:
Fill out application completely.
Owner & Contractor sign back of application, notarized
If over $2500, a Notice of Commencement is required. (A/C upgrades over $7500)
** Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage)
Driveways -Not over Counter if on public roadways..needs ROW
813-780-0020 City ofZephvrhU|ePermit Application rar-813-780-0021
Building Department
NOTICE mpDEED RESTRICTIONS:
than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they
may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and
contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements
may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009,
Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" ofthis
application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is
not entitled to permitting privileges in Pasco County,
TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or
expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that
such fees, as may be due, will be identified at the time of permitting, It is further understood that Transportation Impact Fees and Resource Recovery
Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final
power release, the fees must be paid prior to permit issuance, Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior
to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant,
have been provided with a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of
Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described
document and promise in good faith to deliver it to the "owner" prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with
all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as
indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all
laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I
understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I
must take to be in compliance. Such agencies include but are not limited to:
- Department ofEnvironmental Protauton-Cypress Bayhoada, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
- Southwest Florida Water Management Diotriot-VVe||e, Cypress Bayheoda, VVbt|and Aneea. Altering
Watercourses.
- Army Corps of Engineers -Seawalls, Docks, Navigable Waterways.
' Department of Health & Rehabilitative Services/Environmental Health Und4Ne||s, Wastewater Treatment.
Septic Tanks.
- UGEnvironmental Protection Agency -Asbestos abatement,
- Federal Aviation Authority -Runways.
| understand that the following restrictions apply mthe use uffi||:
- Use offill isnot allowed inFlood Zone ',J''unless expressly permitted.
- If the fill material is to be used in Flood Zone ''A^, it is understood that e drainage plan addressing e
^nompuneating volume" will be submitted at time ofpermitting which is prepared by professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone ''A" in connection with a permitted building using stem wall
construction, | certify that fill will be used only tofill the area within the stem wall.
- If fill material is to he used in any area, | certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect mcUeoent propertiea, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots |eau than one (1)
acre which are elevated byfill, onengineered drainage plan iorequired.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth inthis affidavit prior to
commencing construction. | understand that eseparate permit may be requiredfor electrical workplumbing, signs wells, pools, air conditioning, gas, or
other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as
authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from
thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work
authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a
period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to
exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered
Subscribed and swoRt �(or �irmed) 5fore maAhis Subscribed and sworn to (or affirmed) before me this
Who islare personally known to me or has/have produced Who is/are personally known to me or has/have produced
as identification. as identification.
OYL�z 4&R Notary Public
Commission No.— i f—
Name of Notary typed, printed or stamped
H�H�N��
�
Cummiswion#GG 0454$9
Expires May 3,2024
`»u���
mmA*dTmnmUdo*wmKYomiM
Commission
Name of Notary typed, printed or stamped
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
ate Received
Phone Contact for Permitting
Moyes@drhorton.com
wner's Name
DR Horton Inc
Owner Phone Number
wner's Address
1 12602 Telecom Drive; Tampa, FL 33637
Owner Phone Number
ao Simple Titleholder Name 1,9a171e
Owner Phone Number
ae Simple Titleholder Address
OB ADDRESS
LOT #
UBDIVISION Abbott Park (Zephyr Lakes) PARCEL ID#
(OBTAINED FROM PROPERTY TAX NOTICE)
IORK PROPOSED NEW CONSTR ADD/ALT
SIGN DEMOLISH
El INSTALL 8 REPAIR
ROPOSED USE SFR 0 COMM
OTHER
YPE OF CONSTRUCTION BLOCK FRAME
L I STEEL
,ESCRIPTION OF WORK I
UILDING SIZE I
SQ FOOTAGE = HEIGHT
4L JL 4E W_ k & is
NIA BUILDING $ N/A VALUATION OF TOTAL CONSTRUCTION
N/A ELECTRICAL 1$ N/A AMP SERVICE 0 PROGRESS ENERGY W.R.E,C.
EN!A]PLUMBING $
SA:=
NIA MECHANICAL N/A VALUATION OF MECHANICAL INSTALLATION
[N!A]GAS ROOFING SPECIALTY = OTHER
INISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO
if 944*4 6*4
MILDER COMPANY
;IGNATURE REGISTERED Y/N FEE CURREN L_y N
Address License#
:LECTRICIAN COMPANY
;IGNATURE REGISTERED N FEE CURREN Ly ! N
Address License # I I
I
LUMBER COMPANY
Lawn Medic Landscape & Irrigation
;IGNAT6JRE I
REGISTERED �N FEE CURREN L)IN
—All
Address 4827 Beauchamp Rd; Plant City, FL 33563 License# I SCC131152084
qECHANICAL COMPANY
;IGNATURE REGISTERED Y/N FEE CURREN Y/W
Address License #
)THER COMPANY
)IGNATURE REGISTERED YIN FEE CURREN N
Address License #
1 999A I a am I I V was I is 11111149212 a a 14112.4 I -*Its all al
ZESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction, , I
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans wl Silt Fence installed,
Sanitary Facilities & I dumpster; Site Work Permit for subdivisions/large projects
'OMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction.
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans wl Silt Fence installed,
Sanitary Facilities & I dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance
>IGN PERMIT Attach (2) sets of Engineered Plans.
****PROPERTY SURVEY required for all NEW construction.
)Irections:
Fill out application completely,
Owner & Contractor sign back of application, notarized
If over $2500, a Notice of Commencement is required. (A/C upgrades over $7500)
Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same
)VER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades AIC Fences (Plot/SurveyfFootage)
Driveways -Not over Counter if on public roadways..needs ROW
813-780-0020 City ofZaphvrhi||sPermit Application Fa»813-780-0021
Building Department
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed^restrictions" which may be more restrictive
than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they
may be required to be licensed in accordance with state and local regulations. if the contractor is not licensed as required by law, both the owner and
contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements
may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009.
Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this
application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is
not entitled to permitting privileges in Pasco County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned Understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or
expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that
such fees, as may be due, Will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery
Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final
power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior
to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant,
have been provided with a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of
Agriculture andOonsumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described
document and promise in good faith to deliver it to the "owner" prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with
all applicable laws regulating construction, zoning and land development, Application is hereby made to obtain a permit to do work and installation as
indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all
laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I
understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I
must take to be In compliance. Such agencies include but are not limited to:
Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, VVatenAlVaatewotarTreatment.
� Southwest Florida Water Management Dinthot-WeUa, Cypress Bayheodo. Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers -Seawalls, Docks, Navigable Waterways.
- Deportment of Health & Rehabilitative Gen/ioee/Environmental Health Unit4WoUe, Wastewater Treatment,
Septic Tanks.
- U6Environmental Protection Agency -Asbestos abatement.
- Federal Aviation Authority-Runvvayo.
| understand that the following restrictions apply tuthe use uffill:
- Use offill ianot allowed inFlood Zone ''\y'unless expressly permitted.
- If the fill material is to be used in Flood Zone "A", it is understood that o drainage plan addressing a
compensating volume" will be submitted at time of permitting which is prepared by o professional engineer
licensed bythe State ofFlorida.
- If the fill material is to be used in Flood Zone ''/\^ in connection with a permitted building using stem wo||
construction, I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area. \ certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent propertiem, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for |uta |eao than one (1)
acre which are elevated byfill, anengineered drainage plan iarequired,
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to
commencing construction, I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or
other installations not specifically included in the application. x pannK iavunu s000 be construed to be a license to proceed with the work and not as
authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from
thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work
authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a
period of six (u) months after the time the work is commenced. An extension may be requautad, in writing, from the ou||U|ng Official for period not to
exceed ninety (90) days and will demonstrate justifiable cause for the extension. |fwork ceases for ninety (mo)consecutive days, the job ioconsidered
abandoned.
Subscribed and sworn t affirmed) �bfore mhl, Subscribed and sworn to (or affirmed) before me this
Who is/are personally known to me or has/have produced Who is/are personally known to me or has/have produced
as identification. as identification.
Notary Pub.�Q
HEATHER MUNDT
CommlsWm# GG 84509
ExphoMay 3, 2024
',or*�
mm4aomn S*etwwjynvma
Commission
Name of Notary typed, printed or stamped
Plan Review Comments
I , FFT, shall be a minirnUI-11 M8- above tire, road elevation and an eng"Incered site plan,
21 ors shall be graded to comply kvith IZ40 13 of the F,B,(',
3, Cornpaction test reqtfired it-24" Or more of fill dirt is brouglit in at any one place,
4, 'Tie in survey required betbre pouring concrete,
5, Driveways require as R.OW use permit, All 4 sides ot'driveway thru the sidewalk shall have
expansion material,
6, All setbacks shall be inet,
T All property markers sball be uncovered and marked at time, of first inspection.
8, All A,D,A. requirernente shall be met,
9, No electric, plt,irnbiiig,raiecl,iariical, or fr°aming shall be covered without an inspection and
approval first,
10, All Garages shall comply with section R302.6 of the FB,CII (Fire,', -Separation).
11, Appliances shall not be installed in as location where subJect to are echanical damage unless
protected by approved barriers, M303A of the I-.B.0
12, NNUater heaters shall cotriply with section P6073 of tire F,B,C,
13, Foundation suppoilsfor A/C units shall be raised at least 3" above finished grade, M 1 308A
14, Return air in all bedroorns, M 1 620A
15, Sinoke detectors are to be installed in accordance with R31 3A of the FB,C,
16, All glazing requirements are to be in accordance with R308A of the F13,C',
17, All means of egress are to be in accordance with KI 3 11 of the F B,C,
18. "Green gy-psun, board" shall not be used as as backer in showers or tubs. R702.4,2 F,B,C-
19. Conibinaticart .ype ARA breakers are required at all bocatioris requiring an ARA type breaker,
.0, ("arbon raga noairier alarryis will be required in new construction diat uses fossil -burning heating
or appliances care an attached garage, They shall be instaliCsf ira accordance with the F,BX ' ' ' 2 1, All plurnbing, mechanical, and electrical shall be separate ftoni lunit to unit. 'I"his includes
luall
uridergrOL[rid pluiribing and elec-tric,
22, All 2016 F,(', COdes will be enforced,
423, Tarrip(.r� Resistant Receplacles in accordarree with 406. 11 of tire 2016 N]",("
24, In accordance with the Land Dtn,eloprriem ode, lots shal I be sodded before firial at least 10
fart arOL-Ind the strutcture,
25- R403,5311ot water pipe insulation
Insulation for hot water pipe with a minimum thermal resistance (R-valLi) of R-3 shall be applied to the
following:
Piping,/, inch (19,1 mm) and larder..in nominal diameter,
Piping ser'Ong more than one dwelling unit,
Piping located outside the conditioned space.
Piping from the water heater to a distribution manifold.
Piping located under a floor slab.
Buried in piping,
Supply and return piping in recirculation ysterns other than dernand recirculation systems,
25, Blower door test shall be provided before ('.0,,
26f : , oL e ener cL� s�gll L)e *its EeiLtn iL I a I thy
2 7
2&
F.F.E.-Finished Floor Elevation
FRC- Florida Building Code 6"' Edition
R.O.W.-Right of Way
A.D.A.- Americans with Disabilities Act N.E.C.- National Electric Code (2016)
SITE PLAN
DESCRIPTION:(AS FURNISHED)
LOT 14, BLOCK 13, ZEPHYR LAKES SUBDIVISION PHASE 4B
AS RECORDED IN PLAT BOOK 85, PAGE(S) 126-128, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA.
LOT 15
BLOCK 13
9y9 9.56
(RADIAL)
9�s®
m
Dz
S89°55 50 W
115.00
0 0
m 5' D&AE
n -- I
50.0'
i W ii
m z �
o
a O
m x
25.5 .-=.
m
WI
NVE r 47
3.3,
I O
w i
p
0
L - 12 - 46.7'.
25.7'.----'
0
39:4""'.....-.
- -rn' ' .`� 5, D&AE
N I
w
115.00""
9s3,
S86°43'33"W
(REFERENCE BEARING)
(AAjg
(RADIAL)
Tree Table
Size of Lot (SF) Count
Less than 6,000 1
6,001 - 8,999 2
9,000 - 11,999 3
72,000 - 14,999 4
15,000 - 17,999 6
18,000 - 43,599 8
PREPARED FOR:
FRONT:
20'*
GARAGE:
25'
REAR:
15'*
SIDE:
5'
SIDE STREET:
15'
LOT 13
BLOCK 13
Curve Table
Curve #
Length
Radius
Delta
Chord Bearing
Chord
C7
38.87'
895.00'
3'12'17'
S01'40'1 WE
38.87'
C2
45.31'
810.00'
3'12'17"
S01'40'18'E
45.30'
C3
65.36'
670.00'
535'20'
S02`38'08"E
65.33'
C4
25.21'
670.00'
2i09'21'
SO4'21'08"E
25.21'
C5
40.13'
670.00'
3'25'59"
S01'33'28"E
40.14'
* STAGGERED FRONT SETBACK=
25' FRONT THEN 27' FRONT,
ON 27' FRONT- REAR SETBACK CAN
CAN BE REDUCED TO 13'
NOTES:
1. PROPOSED ELEVATIONS SHOWN HEREON ARE
BASED ON THE APPROVED ENGINEERING PLANS
PREPARED BY HAMILTON ENGINEERING &
SURVEYING INC.
2. ELEVATIONS ARE BASED ON NAVD 1988
DATUM.
THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES
ONLY. THE CONTRACTOR AND/OR OWNER ARE REQUIRED
TO VERIFY ALL SETBACKS, BUILDING DIMENSIONS, AND
LAYOUT SHOWN HEREON PRIOR TO ANY CONSTRUCTION.
THIS IS NOT A SURVEY
THIS IS A SITE PLAN ONLY
FLOOD NOTE: I HAVE EXAMINED THE F.I.R.M. MAP NO.
12101CO293F, DATED 09/26/2014, AND FOUND THE SUBJECT PROPERTI
APPEARS TO LIE IN ZONE "X', AREAS DETERMINED TO BE SPECIAL
FLOOD HAZARD AREAS SUBJECT TO INUNDATION BY THE 1% ANNUAL
CHANCE FLOOD EVENT.THE SURVEYOR MAKES NO GUARANTEES AS TO
THE ABOVE INFORMATION. PLEASE CONTACT THE LOCAL F.E.M.A. AGENT
FOR VERIFICATION.
BEARING BASIS:
BEARINGS SHOWN HEREON ARE BASED ON THE SOUTHERLY LINE OF LOT
14 BLOCK 13 BEING S86'43'33"W, PER PLAT.
(FIELD DATE:)
SCALE: I' - 30 FEET
APPROVED BY: JB
210733 LOT 14, BLOCK
JOB NO, 13
DRAWN BY: BMW
— — BUILDING SETBACK LINE
— - CENTERLINE
- - RIGHT OF WAY LINE
XX•XX PROPOSED ELEVATION
I
�z
1"=30'
GRAPHIC SCALE
PC
a
0 15 30
P
� �
o >
r
v
y�
tea.
tM* o®
gm I
D ;)D
m
S86'43'33"W
25.00' s
I I
i
BROAD POINTE DRIVE
TRACT A
PI
50' WIDE PRIVATE RIGHT OF WAY
WOU01
PROPOSED DRAINAGE FLOW
CONCRETE
A/C
AIR CONDITIONER
S/W
SIDEWALK
FUTURE TREES REQUIRED BY
G'
MPUD / MINIMUM STANDARDS
ON LOT CALCULATIONS
LOT
= 4,840
SQ. FT.
LIVING AREA
= 1,048
SQ. FT.
GARAGE
= 403
SQ. FT.
ENTRY
= 32
SQ. FT.
LANAI
= 80
SQ. FT.
PATIO
= 0
SQ. FT.
DRIVEWAY
= 409
SQ. FT.
A/C PAD
= 9
SQ. FT.
WALKWAY
= 31
SQ. FT.
IMPERVIOUS
= 42%
= 2012
SQ. FT.
SOD
= 2,828
SO. FT.
OFF LOT CALCULATIONS
RIGHT OF WAY
= 501
SQ. FT.
DRIVE APRON
= 152
SQ, FT,
PUBLIC S/W
= 206
SO. FT.
SOD
= 143
SQ. FT.
TOTALS
AREA
= 5,341
SQ. FT.
DRIVEWAY
= 561
SQ. FT.
SIDEWALK
= 237
SQ. FT.
SOD
= 2,971
SO. FT,
PI POINT OF INTERSECTION
PC POINT OF CURVATURE
PT POINT OF TANGENCY
RP RADIUS POINT
PRC POINT OF REVERSE CURVATURE
PCP PERMANENT CONTROL POINT
TYP TYPICAL
CS CONCRETE SLAB
(PI PLAT
C) CALCULATED
PB PLAT BOOK
PGS PAGES
SQ. FT. SQUARE FEET
F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY
F.I.R.M. FLOOD INSURANCE RATE MAP
NAVD NORTH AMERICAN VERTICAL DATUM
D&UE DRAINAGE & UTILITY EASEMENT
D&AE DRAINAGE & ACCESS EASEMENT
DE DRAINAGE EASEMENT
UE UTILITY EASEMENT (PUBLIC)
SURVEYOR NOTES:
1. THE SURVEYOR HAS NOT ABSTRACTED THE
LAND SHOWN HEREON FOR EASEMENTS, RIGHT
OF WAY, RESTRICTIONS OF RECORD WHICH
MAY AFFECT THE TITLE OR USE OF THE LAND.
2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN
LOCATED EXCEPT AS SHOWN.
3, NOT VALID WITHOUT THE AUTHENTIC
ELECTRONIC SIGNATURE AND THE AUTHENTIC
ELECTRONIC SEAL OF A FLORIDA LICENSED
SURVEYOR AND MAPPER.
Digitally signed by James Bateman
-a e DN:c—US, st Flonda, =Orlando,
} • n„"4 ,.-Amercan Surveying &Mapping,
—Professional Land Surveyor,
.email jboteman®asmcorporate cam FOR
^� Date: 202110.2914:55:22-04'00' THE
s Adobe Acrobat version: 11.0.23 FIRM
JAMES W. BOLEMAN PSM# 6485 DATE