HomeMy WebLinkAbout22-3484mw!111 .10 ,— 5335 Eighth Street Zephyrhills, FL 33542 i*'hone: (813) 780-0020 Fax: (813) 780-0021 77 � 777 BAR-003484-2022 Issue Date: 02/28/2022 REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. 111171 IIRIKII Wil 1!1111 EEZI=11=110 I Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNATURE PE IT OFFICEC) THOUT APPROVED INSPECTION 813-780-0020 City of Zephyrhills Permit Application uilding Department g.G Date Received ' J -" Pe p t Contact rmttti Owner's Name - In Owner's Address I J � I C) Afit i \/\IC ) C, ) Fee Simple Titleholder Name y _6 Fee Simple Titleholder Address SUBDIVISION WORK PROPOSED PROPOSED USE TYPE OF CONSTRUCTION DESCRIPTION OF WORK • • Fax-813-780-0021 LOT # C:= i PARCEL ID# µ , )(000C) 0 (OBTAINED FROM PROPERTY TAX NOTICE) NEW CONSTR ADD/ALT SIGN DEMOLISH INSTALL REPAIR SFR 0 COMM OTHER BLOCK E:] FRAME STEEL BUILDING SIZE I SQ FOOTAGE HEIGHT XBUILDING $ VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL AMP SERVICE PROGR SS ENERGY W.R.E. . =PLUMBING $ =MECHANICAL $ VALUATION OF FINISHED FLGAS ROOFING FLOOR ELEVATIONS .. SPECIALTY t FLOOD ZONE INSTALLATION° r OTHER, YES NO CURREN License # ELECTRICIAN --�� COMPANY SIGNATURE REGISTERED Y / N FEE CURREN ( Y / N �- Address License # PLUMBER COMPANY SIGNATURE REGISTERED Y I N FEE CURREN Y J N Address I License # MECHANICAL COMPANY SIGNATURE REGISTERED Y (N FEE CURREN Address I License # OTHER COMPANY SIGNATURE REGISTERED Y / N FEE CURREN Y % N Address License # ��;F1I:II�>����1I����1I��IItIit111tf� RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. ""PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (AIC upgrades over $7500) .. Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades AIC Fences (PlotlSurvey/Footage) Driveways -Not over Counter if on public roadways..needs ROW 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009, Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor. that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner, I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. Southwest Florida Water Management District -Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers -Seawalls, Docks, Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency -Asbestos abatement, Federal Aviation Authority -Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone "W unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1 acre which are elevated by fill, an engineered drainage plan is required, If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the fine the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. FLORIDA JURAT (F,S. 117.03) OWNER OR AGENT Subscribed and swom to (or affirmed) before me this by Who —is/are personally known to me or has/have produced as identification. —Notary Public Commission No. Name of Notary typed, printed or stamped Subscribed and swo4t(V(o ffid) by mtr n Who is/are personally lmown to me or Notary Public Commissi Nq Commission # CG 276457 Name of Bunded Thru Troy Fain Itisurtince 800a385-70119 INSTR#2021251883OR BK PG1472 Page 1 of 1 11/22/2021 11:57 AM Rcpt: 2381558 Rec: 10.00 IDS: 0.00 IT: 0.00 Nik_tAvezSowls, Esq., Pp,co County Clerk Comptroller Thisspace far use by Clerk of the Cuiait Coui only,' l� O 1�E C ;' .,."ONCE PermitNumberi, ...- . Tax Er lio No. Q4-26=21-0120-0000"740: i s The undersigned. hereby gives" ee th9t unproveirtentswW1be inside t® cortaiq,ret9l"11 propertvend in accordance svitli section 711.13 of the Florld i siatutes the following'.'inforiphflan is provided. in the NOTICE OF COMMNCEWNT. 1. Legal Descngtiatx of progeny {street address' ): 247 S ` DF W 2. General dcscrigtian of iistgmnteuts: vtCON RATE F OTER,S SCREEN ENCLOSURE 3a. Owner Name. ti Mi EL'DA ` S .:. " Owner Address: 6247`BOF2D OCID. D ' VEZEPHY tG L ' 2 34. Owner's interest1'-1n site OWNER " 3c. Fee Simphe Title hoidei (of other than owner} ni/A " Address: , 4. Contracto'rNarne:.AFFORDABLE RESCREENING LLG ' Ad". 3100 N 50TH ST-UNiT 1G TAIVIPA FL 33619 Phsxner 8137161369 5. Surety Name Amount'of bond: Address:. 6. ;:ender Name. N/A Contort: Rdiiress: Phanc 7. Person within the State of Florida deszgnsted by owner upon whoin notices or other documents maybe served a§ prtavided by Section 713.13(1)(a)7, Florida"Statutes. _ Name: NIA Address: Phone Namher S. In addition to himself Owner designates the foitowizig Berson to rrxeivo a cogy of dio Licnor s Nance as grovided iiz Section f 713.13(1)(b), Florida- statutes . Name: N/A Address: Phone Number. "a , 9. F.xgimtion,date of Notice of Cominencememt (expiration date is one (1) year from date of recording unless a different date is specified}. 1 YEAR n WARNING TO OWNER: ANY FAY2Ytf.":VTS MADE BY THE OWNERAFM THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED iMPROFER FA f& iJNDER CitAPTFR 713; PART t,,SECTtON'II313, J"RIDA STATUITF.S, AND RESULT IN YOUR PAYING T11_11WICE 1+6 i IiOvTMENT§ TO YOUR;PROPEltM A NOTICE OF COMMENCTSI4IF VT MUST BE RECORDED AND-POSTFD ON1. THE � JOB SITE BEFORE TtlE FIRST INS , _. ON. 'IF YOU' .. � i6 of TAIIV FDdAN6NG CONSULT WITH YOUR I;:ENDER OiB�AN ATTORNEY - . - BEFORE CO N CI1NG WORK OR'RECORDING -YOUR NOTICE OF CO NC Angei l., Mandozac ca'a NOTARY PUBLIC E caSigiature STATE OF FLORIDA of Owner ar I essec; or Owner's ar s AuOffauerll?irector/Pca $E1 C 33 7 EExpir 5/26/1023 OWNER W `o Signatory's Title/Office - 0 STATE t3F FLQRIiIA C 9 wo +ri COUP. pF H LSBOROUGH ,. z 0 z ' The foregoing instawuent was acknowiedge before me this day of 20.. ,t - In � t by Q 1!;i 3 .�-t m o sv; L , , as for 016 � Personally Known' OR Produced l'dentiRcatron Type of Identification Produced Y t A. 13 0 re - Notary`Fubfic Under penalties of perjury, I declare that I hav6sead the foregoing and that the facts stated in it are true to the best of my knowledge and belief. PLOT PLAN DESCRIPTICIN:(AS FURNISHED) LOT 74, OAKS OF PASCO AS RECORDED IN PLAT BOOK 80, PAGE(S) 113-118, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA, ON LOT CALCULATIONS LOT = 6,319 SQ. FT. LIVING AREA = 1,662 SO. FT. GARAGE = 463 SQ. FT. ENTRY = 25 SQ. FT. LANAI = 117 SQ. FT. PATIO = 0 SQ. FT. DRIVEWAY = 417 SQ. FT, A/C PAD = 9 SQ. FT. WALKWAY = 35 SQ. FT. IMPERVIOUS = 43% = 2728 SQ. FT. SOD = 31591 SQ. FT. OFF LOT CALCULATIONS RIGHT OF WAY = 477 SO. FT. DRIVE APRON = 57 SQ, FT. PUBLIC S/W = 298 SQ. F1 SOD = 122 SQ. FT. TOTALS AREA = 6,796 SO. FT. DRIVEWAY = 474 SQ. FT. SIDEWALK = 333 SO. FT, SOD = 3,713 SO. FT. I PREPARED FOR: P4114 1 te BUILDING SETBACKS FRONT- 20' REAR: lo' SIDE: 5' SIDE STREET. 15' `414 JV I NOTES: t PROPOSED ELEVA71ONS SHOWN HEREON ARE BASED ON THE APPROVED ENGINEERING PLANS PREPARED BY CORNELISON ENGINEERING & DESIGN INC. 2, ELEVATIONS ARE BASED ON NAVID 1988 DATUM. 3. FOR ALL LOTS WHERE SIDE -YARD SETBACKS ARE LESS THAN 7.50 FEET, A MINIMUM 5.00 FOOT WIDE DRAINAGE AND ACCESS EASEMENT IS REQUIRED PER PASCO COUNTY LAND DEVELOPMENT CODE. 1" = 30' 0 15 30 PTO 91 ffill"m ggo", QP_ $4' BUILDING SETBACK LINE CENTERLINE RIGHT OF WAY LINE PROPOSED ELEVATION PROPOSED DRAINAGE FLOW CONCRETE A/C AIR CONDITIONER .00, IQ a C) PRO 'k: �,W 7' PI POINT OF INTERSECTION PC POINT OF CURVATURE PT POINT OF TANGENCY RP RADIUS POINT PRC POINT OF REVERSE CURVATURE PCP PERMANENT CONTROL POINT TYP TYPICAL CS CONCRETE SLAB (P) PER PLAT (C CALCULATED PLAT BOOK PGS PAGES General Notes A. CONCRETE & FOUNDATION DESIGN: 1. ALL CONCRETE GRADE BEAMS AND FOOTINGS SHALL BE 3000 PSI MINIMUM. 2. ALL CONCRETE FILLED SUPPORTED SLABS SHALL BE 2500 PSI MINIMUM, 3 1/2" NOMINAL THICKNESS. 3. FIBERMESH (3/4" PER CUBIC YARD MIN.) MEETING APPROPRIATE ACI AND ASTM REQUIREMENTS MAY BE USED IN LIEU OF WELDED WIRE MESH 4. ALL SLABS ON GRADE SHALL BE 4" THICK WITH FIBERMESH. 5. ALL REINFORCING SHALL CONFORM TO ASTM A615, BE GRADE 60 (60 KSI MIN.) DEFORMED BARS, #3 BARS MAY BE GRADE 40 6. ALL OVER POUR CONCRETE FILLED SUPPORTED SLABS SHALL BE 3000 PSI MIN., 2" MINIMUM. THICKNESS. 7. SOIL BEARING PRESSURE SHALL BE A MINIMUM OF 1500 PSF. S. THE CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING: OPC (PORTLAND CEMENT TYPE I,- ASTM C 150). AGGREGATES - 46 STONE, ASTM C 33 SIZE NO. 67 LESS THAN 3/4", AIR ENTRAINING = /- 1 % - ASTM C 260. WATER REDUCING AGENT - ASTM C 494. CLEAN POTABLE WATER. OTHER ADMIXTURES SHALL NOT BE PERMITTED. 9. METAL WELDED WIRE SHALL CONFORM TO ASTM A 185. 10. PREPARE & PLACE CONCRETE ACCORDING TO AMERICAN CONCRETE INSTITUTE MANUAL STANDARD PRACTICE, PART 1, 2, & 3 ALONG WITH HOT WEATHER CONDITIONS RECOMMENDATIONS. 11. IF UTILIZING EXISTING CONCRETE FOR FOUNDATION, CONCRETE SHALL BE A MINIMUM OF 4" IN THICKNESS, VISIBLY FREE OF ANY STRUCTURAL EXCESSIVE CRACKING, SPALLING OR OTHER DETERIORATION. B. MASONRY: I. CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR. 2.ALL MORTAR SHALL BE OF TYPE M OR S. 3.ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 3/8". 4.PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS 5'-0" IN HEIGIIT. C. ALUMINUM: I. ALL STRUCTURAL ALUMINUM SHALL CONFORM TO TILE MINIMUM REQUIREMENTS OF 6005-T5 FOR ALLOY WITH A MINIMUM THICKNESS OF 0.040" FOR SUPPORTING MEMBERS. 2. WHERE KICK PLATES ARE USED A MINIMUM THICKNESS OF 0.024" SHALL APPLY. 3. STRUCTURAL ALUMINUM DESIGN CONFORMS TO "PART I -A - SPECIFICATIONS FOR ALUMINUM STRUCTURES - ALLOWABLE STRESS DESIGN OR "PART 1-B - SPECIFICATIONS FOR ALUMINUM STRUCTURES - BUILDING LOAD AND RESISTANCE FACTOR DESIGN" OF THE ALUMINUM DESIGN MANUAL PREPARED BY THE ALUMINUM ASSOCIATION, INC.WASHINGTON D.C. THE FZORIDA BUILDING CODF 7TH EDITION ( CHAPTER 16 STRUCTURAL DESIGN & CHAPTER 20 ALUMINUM). 4. WHERE ALUMINUM COMES INTO CONTACT WITH STEEL, OR PRESSURE TREATED LUMBER PROVIDE DIELECTRIC SEPARATION. 5. ALUMINUM MEMBERS SHALL BE STITCHED WITH NO LESS THAN #10 SMS 6" FROM THE ENDS AND 12" ON CENTER, IF USING #12 SPACING MAY BE 24" ON CENTER, 6. VINYL AND ACRYLIC PANELS SHALL BE REMOVABLE. THEY SHALL BE IDENTIFIED WITH A DECAL ESSENTIALLY STATING "REMOVABLE PANEL SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 MPH". DECAL SHALL BE PLACED SO IT IS VISIBLE WHEN PANEL IS INSTALLED. 7. I "X2' X0.045" NON-STRUCTURAL MEMBERS SHALL BE ATTACHED TO HOST WITH 1/4"0 X 1-3/4" EMBEDMENT & 24" O.C. MASONRY SCREW FOR CONCRETE & EQUIVALENT SIZE WOOD SCREW WHEN IN WOOD & #10X 1/2" EMBEDMENT SMS OR TEK SCREWS IN ALUMINUM MEMBERS TYPICAL. D. FASTENERS: I. ALL, LAG BOLTS SHALL CONFORM TO STAINLESS STEEL TYPE 300 18-8, WITH STANDARD FLAT WASHER UNLESS MANUFACTURER GALVANIZES BOLTS SPECIFIES FOR USE WITH ACQ PRESSURE TREATED WOOD. 2. HEX BOLTS HAS TO BE ASTM A 325, PLATED WITH STANDARD FLAT WASHERS AND NUTS. 3. ALL CONCRETE SCREWS SHALL BE, SIMPSON, HILTI, RAWL, TAPCON, REDHEAD, DYNABOLT, PORTECT OR APPROVED EQUAL. 4- ALL METAL TIES AND ASSOCIATED ACCESSORIES SHALL BE HOT DIPPED GALVANIZED. 5. ALL LAG BOLTS SHALL HAVE A MINIMUM EMBEDMENT OF 8X BOLT DIAMETER INTO STRUCTURAL FRAMING (G-.42 MIN.). 6. LAG BOLTS AND SCREWS INTO WOOD FRAMING SHALL BE PROVIDED WITH PILOT HOLES HAVING A DIAMETER NOT GREATER THAN 70 PERCENT OF THE THREAD DIAMETER OF THE BOLT OR SCREW. ALL L,AG BOLTS AND SCREWS SHALL BE INSERTED IN PILOT HOLES BY TURNING AND UNDER NO CIRCUMSTANCES BY DRIVING WITH A HAMMER. 7, ALL EXPANSION ANCHORS SHALL BE DESIGNED IN ACCORDANCE WITH THE SPECIFIC MANUFACTURER'S REQUIREMENTS AND ALLOWABLE LOADS AND SHALL ONLY BE APPLIED IN CONDITIONS ACCEPTABLE TO MANUFACTURER. FASTENERS SHALL BE A MINIMUM OF SAE GRADE 45 OR BETTER ZINC PLATED. 8. ALL FASTENERS CONNECTING ALUMINUM COMPONENTS OR PRESSURE TREATED LUMBER ARE STAINLESS STEEL TYPE 300 18-8, UNLESS MANUFACTURER GALVANIZED BOLTS SPECIFIES FOR USE WITH ACQ PRESSURE TREATED WOOD, OR OTHERWISE NOTED ON PLANS. 9. ALL FASTENERS SHALL COMPLY WITH ASTM A153. 10. ALL CONNECTORS SHALL COMPLY WITH ASTM A653 CLASS G-185. 11. FOR SMS, THE MINIMUM CENTER -TO -CENTER SPACING SHALL BE 3/4" AND MINIMUM CENTER -TO -EDGE SHALL, BE 1/2" UNLESS NOTED OTHER WISE. ASTM E 119 ASTM E 1300 CURRENT ASCE 7 CURRENT ALUMINUM DESIGN MANUAL -AA ASM35, AND SPEC. FOR ALUMINUM PART 1-A & I-B ASTM C94 ASTM C150 ASTM C33 ASTM C260 ASTM C494 ASTM A615 ASTM A 185 FLORIDA BUILDING CODE 7THEDIZION (CHAPTERS 16, 20 & 23). THE FOLLOWING LIST OF ABBREVIATIONS IS NOT INTENDED TO REPRESENT ALI. THOSE USED ON THESE DRAWINGS. BUT TO SUPPLEMENT THE MORE COMMON ABBREVIATIONS. 1. TYP - TYPICAL. 2_ SIM - SIMILAR 3. UON --UNLESS OTHERWISE NOTED 4, CONT -- CONTINUOUS 5, VIE -- VERIFY INFIELD G. RESPONSIBILITY: 1. ALL SITE WORK SHALL BE PERFORMED BY A LICENSED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDINANCES, ETC. 2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND DETAILS, NOTIFYING ENGINEER OF ANY DISCREPANCIES BETWEEN DRAWINGS, FABRICATED ITEMS, OR ACTUAL FIELD CONDITIONS. 3.THESE DRAWINGS REPRESENT THE ACCEPTABILITY OF THE 'SUNROOM' ROOM ADDITION ELEMENTS AS PROVIDED BY THE CONTRACTOR. 4, ALL DETAILS ON THESE DRAWINGS ARE ENGINEERED BASED ON INFORMATION PROVIDED BY THE CONTRACTOR AND MANUFACTURER. 5. ANY DETAILS NOT SHOWN ARE TO BE ENGINEERED BY A LICENSED P.E. IN ACCORDANCE WITH STANDARD ENGINEERING PRACTICES. H. MISCELLANEOUS: 1. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A. MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME. IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPARATE 4TH WALL SUPPORT SYSTEM MUST BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. 2. IF ENCLOSURE CONTAINS A SWIMMING POOL OR SPA, THE ENCLOSURE SHALL COMPLY WITH RESIDENTIAL SWIMMING BARRIER REQUIREMENTS OF THE FBC 7THEDITION R 4501.17 IN ITS ENTIRETY. 3. DOOR LOCATIONS MAY BE DETERMINED IN THE FIELD BY CONTRACTOR. 4. IF PAVERS ARE UNDER ALUMINUM MEMBERS THEY SHALL HAVE EPDXY ADHESIVE TO CONCRETE OR IF USING GROUT, ENSURE BONDING AGENT IS USED FIRST AND ADHERED WITH MINIMUM 3000 PSI GROUT. i. SCREENING MATERIAL SHALL BE 18X14X0,013 OR EQUIVALENT DENSITY SCREEN MESH ONLY UNLESS NOTED ON DRAWING S 2. DESIGN DATA: L ULTIMATE DESIGN WIND SPEED Vult, (3 SECOND GUST): NOMINAL DESIGN WIND SPEED Vasd: 2. RISK CATEGORY: 3. WIND EXPOSURE: 4. WIND LOADS: SCREEN ROOF: 6 PSF SCREEN WALLS: 23 PSF SOLID ROOF (SCREEN WALL): N/A ENGINtM l? l ECbRD: David W. Smith P.E. FLORIDA LICENSE: Thomas L. Hanson P.E h 130 MPH 1 L 101 MPH FLORIDA LICENSE: 38654 R Myron Max Neal P.E. FLORIDA LICENSE: 86663 5. FACTOR APPLIED TO SCREEN WIND LOADS FOR 18X 14X0.013 OR EQUIVALENT DENSITY SCREEN MESH: 0.88 6. FACTOR APPLIED TO SCREEN WIND LOADS FOR ALLOWABLE STRESS DESIGN: 0.6 7. LIVE LOAD: 300 1b. VERTICAL DOWNLOAD ON PRIMARY SCREEN ENCLOSURE MEMBERS. 200IF. VERTICAL DOWNLOAD ON SCREEN ENCLOSURE PURLINS. 10 PSI' VERTICAL DOWNLOAD ON SOLID ROOF. 8. PROPOSED I"X8" W/ (1) # 5 REBAR W/ 25" OVERLAP ON 3" CHAIRS W/ 4" MONOLITHIC SLAB W/ FIBER -MESH FILLED W/ 3000 PSI SHALL BE ADEQUATE TO RESIST THE UPLOADS FOR THE PROPOSED STRUCTURE. 9. SCREEN ROOF TYPE: HIPPED GABLE 10. SOLID ROOF"TYPE� N/A a - HOLLOW SECTIONS 2 x 2: -- --------------------------------2" x 2" x 0,044„ 2 x 3: --- -------------------------------2" x 3" x 0.050„ 2 x 4:-------- -----------------------------2" x 4" x 0.050" 2 x 5:--------------------------------------2" x 5" x 0.050" 3 x 3:---------------------------------------3" x 3" x 0.125" OPEN BACK SECTIONS 1 x 2:------------------------------ 1" x 2" x 0.040" 1 x 3: ------------------------------1" x 3" x 0.045" NNIATIONYGIMN 2 x 2 SMS:----- -----------------------2" x 2" x 0,045" 2 x 3 SMS: -----------------------------2" x 3" x 0.072" 2 x 4 SMS:----------------------------- 2" x 4" x 0.045" 3 x 3 SMS: ----------------------------- 3" x 3" x 0.090" s 2 x 4 SMI3:---------------------- 2" x 4" x 0.044" x 0.100" 2 x 5 SMB:---------------------- 2" x 5" x 0.050" x 0.118" 2 x 6 SMB: -------------------- 2" x 6" x 0.050" x 0.120" 2 x 7 SMB:---------------------- 2" x 7" x 0.057" x 0.120" 2 x 8 SMB:----- ---------------- 2" x 8" x 0.072" x 0.224" 2 x 9 SMB:---------------------- 2" x 9" x 0.072" x 0,224" 2 x 10 SMB:------------------- 2" x 10" x 0.092" x 0.374" TUBE SECTIONS 2 x 2:---------------------------------------2" x 2" x 0.090„ INDEX: S-1 GENERAL MOTES S-2 DRAWING S-3 DETAILS S-4 DETAILS o �IT Ul 4 tiIFF r >S v s V_,5 C 1 T I%Yl ,, f FLORIDA LICENSE: 70667 Erik Stuart P.E. FLORIDA LICENSE: 77605 FPE Plans & Engineering Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephgrhills, FL 33542 Ph# (813)788-5314 Fax# 1-(866)824-7894 E-mail-erb@fbcplans.com Website-www.fbcplans.com C.O.A.429054 DATE: 11/02/2021 DRAWN BY: ST REVISION: DATE: RO 1 RO 2 RO 3 RO 4 •b' 211102031 PROJECTCD s RAVIS • NOTES 1x2 X 2x5 2 x 2 X 1x2 - - - - - - - - - - - - - - ---- IN PROPOSED 8"X 8" W/ (1) #5 REBAR FOOTING W/ 4" MONOLITHIC SLAB L A 40 P 6 % 10 Nos 70667 • STATE OF • :Z 0 Q.• OD X PROF SS I ER SEAL ENGINEER OF RECORD: David W. Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson P.E FLORIDA LICENSE: 38654 Myron Max Neal P.E. FLORIDA LICENSE: 86663 oel Falardeau P.E. LORIDA LICENSE: 70667 Erik Stuart P.E. OD FLORIDA LICENSE: 77605 FBC Plans & Engineering Services, Inc. K 6272 Abbott Station Dr. Unit 101 0 Zephyrhills, FL 33542 1 Ph# (813)788-5314 Fax# 1-(866)824-7894 E-mail-erb@fbcplans.com Website-www,fbcp1ans.com 0 C.O.A.429054 DATE: 11/02/2021 DRAWN BY: ST REVISION: DATE: RO 1 DOOR LOCATION MAY BE DETERMINED FE (TYP) IN THE FIELD BY THE CONTRACTOR. RO 2 RO 3 R04 Job# 211102031 PROJECT ADDRESS: DAVIS 1247 BRADFORD WOODSDA CEPHYRHILLS, FL 33542 :ONTRACTOR: PURLIN L ] $" 1I GA. ALUMINUM �Ogi0*0� 2" x_PURLINS (SEE S-2 FOR ( ) OPTION #2 O� SIZEAT'1ACHEDTOSEAM GUSSETPLATE(2XHEIGHT) UPRIGHT WEB LAPPED OVER PURLIN W�� \ W/ (4) #1OX3/4" SMS EACH SIDE OPTIONAL w/M1N (4) #10 x 1 �" SMS 'N. B #12 SMS NOTE: 2"x3" SPECIAL MAYBE USED IN LIEU ( � � OF 2"x2' W 1"x2" COMBO ^� O 0 O O 0 2" x 2" x0.045" SAVE RAIL MEMBER (UNLESS OTHERWISE NOTED ON OO =ZX4M ONLY RE UIRHS 4" -z)ATTACHED To Puru,IN w/ (2I Z-BRACKEP0211' Q N ® , #1oX4"SMSTxeuSCREWBOSS ^ " ' 'CKET W/ (2) 1/4" ® ! 1 X2"XO.O45" OPEN BACK O O $ NOfCH POST S", 7", OR 9"X 6" WIDTH X 0.250" ATTACHED TO PURLIN W 2 EXTRUDED GUTTER BRACKET @ #10X1-1/2" SMS INTO (4) 1/4" LAG SCREWS @ 1-1/2" N O e s e EA. BEAM W/ (4) #12 X 3/4" BOSS SCREW �? SPACING @ EA. GUTTER BRACKET cross�� SMS INTO GUTTER LIP `. & (1) @ 12" O.C. MAX- MIN EMBEDMENT rxz'Xo.04s OPEN aACK, SHALL BE 2' ATTACHED E z xz xo 045" elcxr PROF dr t I 1 SEAL E#1 MILM£MBEA PRE -FRB ONLY �y4 � #10X1-1/Z SMS BACK W/ x00452 x' zjz A ti N �z @121,OC ENGINEER OF RECORD: �— @BEAM&ATGUTTER 53 E�Ag1�$� David W. Smith P.E. PURLIN ATTACHED TO SAVE RAIL. MAY USE zxz IN LIEU of W/2'x2"x0.12S" INTERNAL FLORIDA LICENSE: 53608 1X2, USE #1OX2-1/2" '� RECEIVING CHANNEL OR TEKS, SAME PATTERN �',�' 1�� EXTERNAL 0.125" ANGLE CLIP ATTACHED 'T�h�yyy T Hanson �*�y� 7i E APPLIES V W/{3) #12x3/4" SMS EA. LEG Thomas L. 1 1 11,3 Al S- NOTES: FLORIDA LICENSE• 38654 00 BEAM O O 00 0 \ 0 2" x2" x 1/8" XALUMINUM THE HOST STRUCTURE SHALL ANGLE w/ (4) #12 x 3/4" HAVE AT LEAST A 2"X4" IVERIFY SMS INTO BEAM ON EA SIDE FASCIA AND ROOF TRUSS EA. LEG SYSTEM. CONTRACTOR SHALL. THIS AND IF 2"X2"XO.062"RECEIVING (4) 412 x 3/4" SMS SMALLER -CONTRACTOR CHANNEL W/ (2) #10X 3/4" INTO GUTTER EA SIDE SHALL BRING STRUCTURE UP EA SIDE TO COVER EXPOSED TO A 2"X4" FASCIA AND BEAM ENSURE LESS THAN A 2'-0 OVERHANG. .+MED.MMMMMMMM ® 1. "N" NUMBER OF SCREWS IN ANY 2"x3" FACE RAIL DIRECTION. � 1-1/z'x6'x0.125"BAR Zxkl OPTION #1 Lriyj'0n Max Neal P.E. Myron 2, TOTAL NUMBER OF SCREWS PER w/ 6 #12x3/41' SMS JOINT EQUALS 4 TIMES "B" I 39 SAVE FLORIDA LICENSE: 86663 3. PLATE WIDTH SHALL BE POST PURLIN �� a�ard�a3 P.E. DETERMINED FROM ANGLE OF j FASTEN RECEIVING CHANNEL ILORIDA BEAM AND MIN. SPACE REQUIRED. j TO BOTTOM OF SAVE RAG- 0 O 01. 0060' RECEIVING CHANNEL. LICENSE: 70667 W/(4) #12x3/4" SMS (1 x2" x POST SITE) 4. GUSSET PLATES EXTERNAL. ATTACHED TO POST 1> S. INTERNAL SCREWS FOR PURLIN W/(3) #120/4" SMS EA. SIDE StuartT Erik StP.E. CONNECTION MAY BE INCLUDED IN -OR- `x2'k0125" FLORIDA LICENSE: 77605 OF SCREWS. ALUMINUM UPRIGHT 2 ALUMINUM ANGLE TOTAL NUMBER TOTAL BOTH SIDES OF POST ATTACHED 6. GABLE SPLICE WILL HAVE THE w/(s) #12x3/4"SMS EACH LOG. SAME PATTERN. FBC Plans & Engineering l A GUTTER BRACKET & BEAM ATTACHMENT DETAIL 6272 Abbott Station Dr. Unit 101 S_3 N.T.S. B #12 SMS BEAM SPLICE GUSSET DETAIL. S-3 C Zephyrhilis, FL 33542 SCALE: SITS SLOPED OR FLAT PURLIN UPRIGHT LAP DETAIL S-3 SCALE:NTS r Ph# (813)788-5314 Fax# 1-(866)824-7894 E-mail-erb@fbcplans.com -- — -------.---- -- -- Website-www.fbcplans.com BEAM SCREWS ° EDGE MEMBER CO,A.-#29054 2X 4° SMB 6 OR PURLIN 2" X 5 SMS 6 2 #IOX4" SMS INTO SCREW () 2" X 6 "SMB 8 BOSSES FOR EDGE MEMBERS 2" X 7" SMB $ — — — DATE: 11/02/2021 2" X 8" SMB 10 2"X9"SMB 10 DRAWN BY: ST HINGE LOCATION 2" X 1.0' SMB 12 ®; 0.125" FLAT PLATE OPTION # 1 ®� W/ (12)#1QX3/4" SMS REVISION: DATE: / ® OR (B) #1.4X 3/4" SMS 2" x 2" EXTRUSION 2" x 2" EXTRUSION FOR SLOPED BEAMS, (MIN. 1/2" EDGE DISTANCE) RO 1 MAINTAIN ALL SCREW SPACING RO 2 HINGE LOCATION DOOR FROM EDGE OF BEAM -'SELF-MATING BEAM SHALL BE NOTCLIED EDGE MEMBER RO 3 FORUPRIGHT OR PURLIN 2" x 2" EAVE RAIL SECTION i RO 4 (UNLESS OTHERWISE SHOWN TOb# 21_1102_031 ON S-2) - ATTACHED TO BEAM w/ (4)1ox z° SMS INTO SCREW ® BOSS I BOTH ENDS SIMILAR PROJECT ADDRESS: �� 00 1" X 2" OPEN SACK F.AVF. OPTION #1: 2" x 2" x PURLIN I DAVIS HINGE LOCATION RAIL ATTACHED TO Q,I DEPTH RECEIVING CHANNEL W/ (4)#IOX3/4" EA.LEGATTACHING 6'Z47 BRADFORD WOODS DR �/ UPRIGHT w/(2) PURLIN TO BEAM OR FAVE I 1 ZEPHYRHILLS, FL 33542 #10 x 1 Y2" SMS INTO SCREW MEMBER P'l)SS .060 RED. CHANNEL MIN. ( I NOTES: #10 X 1 X" SMS 24" C/C ( I L HINGES SHALL BE ATTACHED TO STRUCTURE W/ (4) #10 x 5/8" SMS MINIMUM. 4° (MIN) UPRIGHT I I CONTRACTOR: 2. DOOR SHALL BE ATTACHED TO ENCLOSURE w/(2) HINGES MINIMUM. #14X 3/4" SCREWS (SL'iE TABLE ABOVE) I ( ! / AFFORDABLE RESCREENING 3. HINGES SHALL BE ATTACHED TO DOOR WITH (3)#10 x 5/8" SMS. FASTEN A OPTION #2 ( 1100 N 50TN STREET, UNIT 16 1" x 2" x 0.044" TO UPRIGHT W/#12 x 1" SMS @ 12" O.C. AND WITHIN 3" FROM FLORIDA 33619 END ND OF THE UPRIGHT. TYPICAL SCREEN DOOR CONNECTION DETAIL DETAILS SCALE.NTS D UPRIGHT TO BEAMCONNECTION - AL.L WIND ZONES E SCALE: NTS J ROOF BRACING CONNECTION DETAIL S-3 SCALE: N.T.S. 1 �1I I If 111 UPRIGHT � ,�.*0900.�� ENS OPTIONAL SECONDARYANGLE MIN ® 0.125" THICK (NOT +� (4) #10 X 3/4"SMS RE U1RED FOR 2X3o.70667 FASTENING SECONDARY Q 5° T', OR 9"-X 0.250" ANGLE TO COLUMN (TY MEMBER) EACH SIDE EXTRUDED GUTTER ) PRIMARY 2" X 2" Z-BRACKET 0.250" BRACKET i X 0.125" ANGLE 2" GUTTER BRACKET REQUIRED (B) - CONCRETE SCREW (2) #10 X 3/4" SMS FASTENING � �����`� Q ANCHOR INTO SECONDARY I C AT PURLIN ATTACHMENT 1 ... ..gam POINTS w/ (2j #1"2 X 3/4" SMS (1) 1/4" LAG SCREWS @ EA. GUTTER ANGLE(TYP EACH SIDE SEE COLUMN TO PRIMARY ANGLE �w TABLE) {TYP EACH SIDE) ��� INTO GUTTER LIP BRACKET & (1) @ 12" O.C. MAX- MIN OPTION #1 OPTION #2 ® ti u' 1" X Z" BASE MEMBER EMBEDMENT SHALL BE 2" 1" x 2" x 0.045" OPEN BACK W/ (4)#10 x 1 X" SMS RECEIVING CHANNEL (TYP EACH SIDE) (2)#10X 2" ATTACHING TO INTO SCREW OR ANGLE EA. SIDE (typ) ANCHOR SPA 1 CONCRETE SCREW PRO 5 NF GI . EER SEAL GUTTER& (1) @ 24" O.C. BOSSES L0625" THICKNESS) (MIN) (TYP)(SEE TABU) O (SEE Gi TABLE) ANCHOR INTO PRIMARY ENGINEER OF RECORD: ANGLE AND @ 1/4" 0 CONCRETE n �j 3" (MIN) 240 C. BETWEEN COLUMNS SCREW ANCHOR@ David YY . Smith r .E. PURLIN — — — — — — — — — FLORIDA LICENSE: 53608 00 2"12" OR 2"X3" (2) #1.0x 3/4" SMS 00 PURLIN OR GIRT (typ) EA. LEG) (TOTAL 6 SCREWS R.C. (8) SCREWS ANGLE EA. CONNECTION) 2" x 2" x Y8" X ALUMINUM ANGLE w/ (4) #12 x 3/4" THE HOST STRUCTURE SHALL SMS INTO PURLIN ON EA HAVE AT LEAST A 2"X4" SIDE & (4) 12X1-1/2" INTO GUTTER FASCIA AND ROOF TRUSS PURLIN OR GIRT TO BEAM OR POST DETAIL SYSTEM. CONTRACTOR SHALL S-4 SCALE: NTS VERIFY THIS AND IF SUPER GUTTER SMALLER- CONTRACTOR SHALL BRING STRUCTURE UP Column Size 1/4"& 3/8" 0 Concrete Screw Anchor B Min. Spa 2x3-1/4" 0 0" 2x4-1/4" 1 3" 2x5-1/4" 1 3" 2x6-3/8" 1 4" 2x7-3/8" 1 5" 2x8-3/8" 2 3" 2x9-3/8" 2 4" 2x10 3J8" 2 4,5" NOTES: (TYP EACH SIDE) l anson P.E Thomas L. Hanson 1. NUMBER OF ANCHORS "B" IS EACH SIDE INTO THE SECONDARY ANGLE AND DOES NOT INCLUDE THE ANCHOR INTO THE 1X2. FLORIDA LICENSE:�38654 2. MINIMUM EMBEDMENT OF ANCHORS INTO CONCRETE FOOTING iv Myron Max�t�� P.E. SHALL BE 2-3/4" AT AT ALL UPRIGHT LOCATIONS. ALL SCREW LENGTHS AT UPRIGHT CONNECTIONS SHALL BE OF SUFFICIENT FLORIDA LICENSE: 86663 LENGTH FOR REQUIRED EMBEDMENT INTO CONCRETE FOOTING WHEN A PAVER DECK IS PRESENT. 7 Joel Falardeau P.E. 3. CONCRETE SCREW ANCHOR DESIGNS ARE BASED ON THOSE LIST FLORIDA LICENSE: 70667 ON S-1, D. FASTENERS, OTHER BRAND & TYPE SHALL BE APPROVED 7 Erik Stuart P.E. BY ENGINEER 4. 2X3W/1X2 CORNER POST SHALL REQUIRE SAME, BASE FLORIDA LICENSE: 77605 CONNECTIONS AS 2X4 SHOWN IN TABLE, 5, IF FOR AN IN -FILL, TOP OF COLUMN CONNECTION SIMILAR IF TO A 2"X4" FASCIA AND ENSURE LESS THAN A 4'-0" OVERHANG. GUTTER BRACKET & PURLIN ATTACHMENT DETAIL CONCRETE LINTEL, IF WOOD LINTEL SUBSTITUTE 1/4" 0 X 3" LAG SCREW FOR 3/8"0 LDT FOR BOTH PRIMARY & SECONDARY ANGLES. 6. 2X21045 DOOR JAMB MEMBER SHALL CONNECT SIMILAR TO 2X3 MEMBER. G 2" x 3" OR LARGER UPRIGHT TO CONCRETE, W WO PAVER DETAILS FIX Pic` ns & Engineering °I V1C£,S, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 S-� N.T.s. S_4. SCALE: NTS Ph# 1,813)788-5314 Fax# 1-(866)824-7894 -- - -- - -- -maI -er cp ans.com NOTE: WHEN USING OPTION #2 5 Website www.fbcpians.com OPTION #1 2500 PSI _ i MIN. CONNECTION CABLE MUST BE C,O,A,-#29054 oI 0.125" STAINLESS CONCRETE W/WELDED WIRE OR FIBERMESH WITHIN 6" OF CORNER OR ® ® ® ® 1/8" ALUMINUM STEEL CABLE PRIMARY MEMBER. PLATE @ 45' a 1' X 2" X 1./(4)ANGLE ANGLE WJ 1" DATE: ll/02/2021. 3 1/2" (4" NOMINAL) a BREAK @ 90° W/ SLAB MINIMUM 12 X3/4" SMS ® 5/16" EYE BOLT DRAWN BY: ST (TYP TOP AND SIDE) W/ LOCK NUT & 3/8" 0 x 3" MASONRY WASHER EA SIDE REVISION: DATE: ANCHOR GRADE OPTION #1 (4" SLAB ONLY) OPTION #2 - A-36 STEEL CLIP 1/8" CIA, STAINLESS (9) 914 X 3/4 SMS RO 1 � MAY BY PLACED ON TOP OR STEEL CABLE @1" O.C. RO 2 L DOUBLE COMPRESSION SIDE OF DECK W/ (2) 3/8"X 3" - (1)#s REBAR CONTINUOUS W/ 2S" SLEEVES TOP OF CONCRETE SLEEVE ANCHOR 3/8" WELDED STAINLESS RO 3 PATALLJOINTSON3" �8"� OVERLAP 4"NOMINALSLAB STEEL EYE BOLT OPTION #3 (8) #14 X 3/4 SMS RO 4 TYPE It MONOLITHIC SLAB MINIMUM 4 Side View JOb# 21_1102_031 MODERATE SLOPE FTG tr SLOPE: 2":12" - 3":12" d a-----BENEATHNUT 1" 0 (MIN) WASHER — PROJECT ADDRESS: NOTES FOR ALL FOUNDATION TYPES: 3/8" x 3" MASONRY ANCHOR (MIN 3-3/4" 2500 PSI CONCRETE W/ OPTION #z WIRE. OR — DAVIS EMBEDMENT) (4" SLAB ONLY)WELDED FIBERMESH e gi ® s 6247 BRADFORD WOODS D 1. THE FOUNDATIONS SHOWN ARE BASED ON A MINIMUM SOIL 0.125" STAINLESS — _ — — — ZEPHYRHIL.LS, FL. 33542 BEARING PRESSURE OF 1,500 PSF. THE BEARING CAPACITY OF THE ( STEEL CABLE 2500 PSI CONCRETE W/ SOIL VERIFIED BY A LICENSED CONTRACTOR PRIOR TO ANY POURING OF CONCRETE. = Top Op WELDED WIRE OR Top View 3/8" 0 ADJUSTABLE EYE p oil] I CONCRET' E BERMESH BOLT FOR CABLE TENSION 2. THESLAB/FOUNDATION MUST BE CLEARED OF ALL DEBRIS, AND a.. ®� CONTRACTOR: COMPACTED PRIORTO POURING OF ANY CONCRETE.. 4" NOMINAL SLAB a OPTION #2 1/8" 0 STAINLESS 3. CONCRETE MEET THE SPECIFICATIONS IN THE S-1 NOTES PAGE. MINIMUM d STEEL CABLE AFFORDABLE RESCREENING 1100 N 50TH STREET, UNIT 16 1-1/2" x 5-1/2' a K ALUM.sTRAP W/ (z) 3/B a TAMPA FLORIDA 33619 TYPE II MONOLITHIC SLAB FOOTING -O X 3" MASONRY-- PERIMETER FRAMING 2"XZ"X 1/8" EXTRUDED ANGLE S-4 ANCHOR (MIN 3-3/4" OPTION #2 ON 45° ANGLE EMBEDMENT) (USE WITH FOOTING) Side View OPTION #1 DETAILS J1 CABLE TO FOUNDATION CONNECTION DETAIL S-4 SCALE: NTS 12 CABLE CONNECTION AT CORNER S-4 SCALE: NTS COMPANY NAME: AFFORDABLE RESCREENING LLC COMPANY ADDRESS: 1100 N 50T" ST UNIT 1G CITY, STATE, ZIP: TAMPA, FL 3 619 PHONE NUMBER: 813-716-1389 EMAIL: affordabl rescreersira Iive.corT) 1, THE UNDERSIGNED DO HEREBY AUTHORIZE THE FOLLOWING INDIVIDUAL(S) TO ACT AS MY AGENT(S�l IN OBTAINING PERMITS M SUPERSEDESTHIS LETTER ANY PREVIOUSLY SUBMITTED4 OF AUTHORIZATION. WILL DELETE y�AND REPLACE t A ANY PREVIOUS F rAUTHORIZATION ,7�Y� LETTER AND THE INFORMATION THEREON. AUTHORIZATION CANCELLED BY THE UNDERSIGNED. TYPED OR PRINTED NAME a b i" b DATE STATE OF COUNTY OF � (printed name of notary) Personally ORproduced Identification L/