Loading...
HomeMy WebLinkAbout22-3485Issue Date: 02/11/2022 5335 Eighth Street Zephyrhills, FL 33542 Phone: (813) 780-0020 Fax: (813) 780-0021 05 26 21 0080 00600 0230 Name: KENNETH & SAMATHA PERCH Permit Type: Alter (Residential) Class of Work; d/Alter Residential FTITHOHIIIKKTRNT*Tllk�� Building Valuation: $17,000,00 Electrical Valuation: $1.00 Mechanical Valuation: $1.00 Plumbing Valuation: $1 00 Total Valuation: $17,003.00 Total Fees: $187.50 Amount Paid: $187.50 Date Paid: 2/11/2022 9:17:25AM REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. 6 1 0 1 a M... MO. *IF= � 1 11 • 0 . . 0 Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. /Af CONTRACTOR SIGNATURE PEfIT 6F6CIEf j V RM-72- =152 7.70,01171 WITITI wall R, �14: INSTR# 2023609 OR BK10649 PG2422 Page 1 of 2 02/11/2022 08:43 AM Ropt: 2415767 Rec: 18.50 DS: 0.00 IT: 0.00 Nikki Alvarez Sowies, Esq., Pasco County Clerk & Comptroller •4 Permit No. Paroal ID No C0 hw NOTICE OF COMMENCEMENT State of County of THE UNDERSIGNED hereby gives notice that Improvement will be made to cadain real property, and In accordance with Ch ter 713, Ftooda�jatutes, the following Information is provided in this Notice of commencement:(, 1,.( j LaflEraar'}rLp' 1 5( 1. Destxiption of Property: Parcel Identification No,! Sib. % r�'" ` FrLY b°%S-',�ict fp i3Oi - 3 Street Address: tO u11 fq G o A (✓fit 1 .—a 2. General Description of Improvement _.! "Tll f 14 K a f ° .S IlAb d" k �• 1�L Wf# `L4I-AACJ 3. Owner Information or Lessee information if the Lassescontracted for the Improvement: a 5ama -,tN 33SW Address city State Interest in Property: CA.d'rka1 _ - - - Name of Fee Simple Tigaholder. (If dttlerent from Owner listed above). " Address City State a. Contractor: 4�{ TLiD t 'ut Name s^+% t�.,, , t.., Ql ' r�f" s� d`4. State Contractors Telephone c_ 4 j pN/'o..: 5, Surety: I JIA Name Address City "j2 State Amount of Bond: S Telephone No.: ,l•f (( 6. i Lender. _�.� • Name -• City._ Lender's Telephone No.: 7. Persons within -the State of Florida designated by the owner upon whom notices or other'locuments may be served as -provided by Section 713:13(1)(a)M, Florida Statute/ Address Cltp _ _ State Telephone Number of Designated Person: 8. In -addition to himself, the owner designates /v of — to raceive a copy of the Uanoes Notice as proNBed In Section 713.130)(b), Florida Statutes. Telephone Number of Person or Entity Designated by Owner. 9. Expiration date of Notice of Commencement (the expiration date may not be before the completion of construction a flnai payers a the contractor, but will be one year from the date of recording unless a different date is specified): S r Under penalty of perjury, I declare that I have read the foregoing notion of commencement nd that the ;factstate therein are true to the best of my knowledge and belief. STATE OF FLORIDA. COUNTY OFPASCO Signs of Owner or Lessee, or Owners or LessWs Authorized Offloer/Directodloortnedivanager r Signatory's TkletOfa t The foregoing Instrument was acknowledged before me this _day of , 20 _ by as (type of authority, e.g., officer, trustee, agomeyln fad) for (name of party on behalf of wham Instrument was executed). Perspnaliy Known ❑ OR Produced Identification ❑ Notary Signature Type of identification Produced Name (Pdnt� ` wpdatatbcstnofcecommencerneni pcD53048 OR BK10549 PG2423 Page 2 of 2 Acknowledgment by Individual M= SM&I The foregoing instrument was acknowledged before me this 0--�A *4* ---1,------ day VC (=c M"p`hysical presence or ❑online notad ation of 20 by means of z -�evinel� ---- (name of person acknowledging). ell OrAct Notarvj name 117,ed or 1,rinted�, I Title NotaM Ptibli-cL A).�. Placn.45eial Here my Comm Expl".. APM15,,V3 3(J) ® '40- 06 323832 • ,A% ti Nikki Alvare 7 Iq K, a 0 V11 --- �, Cl' k & Comptroller For Bank Purposes Only Description Pasco z-Sowvi�es, Esd��ir� L /906�ty, Florid*� MBO 1RMW of Attached Document B Deputy Clerk Type or Title of Document State Of Florida, County Of Pasco This is to certify that the foregoing is a trve and correct COPY of the document on file or of Public record in this office. Witne%my hand and official seal this day of "` ' - 0, -',, - ,- , 2 /1—L-2 Document Date Number of Pages ao 0 Signer(s) Other Than Named Above Account Number (if applicable) --------------- 0 0 2020 Wells Fargo Bank, N.A. All n ,ghts reserved. DSG5350FU595501 (Rev 06- 05/2 1) 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permitffn t7J &&fail..,... Is Owner's Name I keAim P / Owner Phone Number 7 4/ Owner's Addressl t 1 Owner Phone Number Fee Simple Titleholder Name—®� Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS jlg ! { LOT# SUBDIVISION PARCEL to# � t (""° t o "� t,.t,.!s '""02,3o fRRYBiNFR FRRAi RY?R@F@YY TAY PIRTI(`FY • BUILDING SIZE ILDING $ s y op(VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ f AMP SERVICE PROGRESS ENERGY W.R.E.C. =PLUMBING $ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATI NEW CONSTR ADDlALT INSTALL REPAIR SFR 0 COMM BLOCK E:] FRAME SIGN = DEMOLISH OTHER STEEL =GAS ROOFING SPECIALTY !4,_..._1 OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY% SIGNATURE + REGISTERED Y 1 N FEE CURREN Address License # -6- i ) ELECTRICIAN - COMPANY_ � SIGNATURE REGISTERED YIN FEE cuRREN Y f N 4 Address License # PLUMBER ftj COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y I N Address License # MECHANICAL COMPANY SIGNATURE REGISTERED Y l N FEE CURREN Y I N Address License # OTHER COMPANY SIGNATURE REGISTERED YIN FEE CURREN Y I N Address License # r"��— _ ���s��s:€e��ss�ttsa�s�saassas��xsass�asa;as�satl��tps��s���st�s; RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans wJ Silt Fence installed, Sanitary Facilities & 1 dumpster, Site Work Permit for subdivisionstlarge projects COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans wf Silt Fence installed, Sanitary Facilities & 1 dumpster, Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans, ****PROPERTY SURVEY required for all NEW construction. Directions: Filloutapplication completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (AIC upgrades over $7500) Ag—t (fog the —t—tor) of Power of Att.rnoy (for the owner) woulo be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage) Driveways -Not over Counter if on public roadways..needs ROW 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed' restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions, UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law, if the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009, Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the 'contractor NOW of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not property licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy' or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant, have been provided with a copy of the 'Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner, I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement CONTRACTOR'$/OWNEWS AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies Include but are not limited to: Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. Southwest Florida Water Management District -Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers -Seawalls, Docks, Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency -Asbestos abatement. Federal Aviation Authority -Runways. I understand that the following restrictions apply to the use of. fill: Use of fill is not allowed in Flood Zone W" unless expressly permitted. If the fill material is to be used in Flood Zone 'A", it is understood that a drainage plan addressing a "compensating volume' will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone 'K in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall, If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required, Iflarrithe AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, after, or set aside any provisions of the technical codes, nor shall Issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the pen -nit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. VIUMUS LgNQF.R 98 AN &MBUX 15F.Q289 REOR12INQ XQM8 NOICE QE COMMENCEMENT- FLORIDA JURAT (F.S. 11 T03) OWNER OR AGENT CONTRACTOR Subscribed and swort _rned) Mfbre this Subscribed and sworn tgy(or affirmed) s y I= b �Wh. _,slare pers�nally �known to me or has/have produced Who istare personally known to me or has/have produced as identification. as identification. 0—mmilon Notary Public Notary Public Commission Name of Notary typed, printed or stamped Name of Notary typed, panted or stamped BOUNDARY & AS -BUILT SURVEY DESCRIPTION: (AS FURNISHED) LOT 23, BLOCK 6, SILVERADO RANCH SUBDIVISION PHASE 6, 8 & 9A AS RECORDED IN PLAT BOOK 75, PAGE(S) 75-- 80, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. j® 4 EXCLUSIVE USE y . DHI TITLE OF R' MORTGAGEDHI • OLD REPUBLIC NATIONAL TITLE 1. ALL DIRECTIONS ! DISTANCES VERIFIED, INCONSISTENCIES HAVE BEEN NOTED SURVEY, IF ANY. 2 1 PROPERTY CORNERS SHOWN HEREON WERE SET/FOUND ON Y UNLESS OTHERWISE SHOWN. HEREON3. THE SURVEYOR HAS NOT ABSTRACTED THE LAND SHOWN #" EASEMENTS, RIGHT OF # OF RECORD WHICH MAY AFFECT THE TITLEOR USE OF BUILDING4NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCATED. #.. # # BOUNDARY ! PC g 09���5 GRAPHIC SCALE 0 15 3C b\\�w r� G�, ® sAs^`Ft �"'`xs`r • ~ a�,A R� CaQ � a. tl� # _ '7'lA:: RIGHT OF •• 'RR AND CAP DRAINAGE FLOW EXISTINGj R I It ji LEI jF7013 A/C AIR CONDITIONER 0R. R R IRON! .. ►CAP O (P) PER PLAT ONCRETE BLOCK WALL PC POINT OF CURVA11JRE R,�.CaW CORNER RACCESSIBLE POO POINT OF COMPOUND .R CONCRETE PAD PCP PERMANENT CONTROL POINT CONCRETECP CS I'l POINT R i' CONCRETEr 'PC '+ !" yR ERGE' # ^ {+ � ! INSURANCE., FLOODR P... O ... R LINE R2. -MON PONTOF REVERSE CURVATURE La LICENSED allSINESS PRM PERMANENT REFERENCE MONUMENT PROFESSIONALID SURVEYOR AND MAPPER U General Notes A. CONCRETE & FOUNDATION DESIGN: 1. ALL CONCRETE GRADE BEAMS AND FOOTINGS SHALL BE 3000 PSI MINIMUM. 2. ALL CONCRETE FILLED SUPPORTED SLABS SHALL BE 2500 PSI MINIMUM, 3 1/2" NOMINAL THICKNESS. 3. FIBERMESH (3/4" PER CUBIC YARD MIN.) MEETING APPROPRIATE ACI AND ASTM REQUIREMENTS MAY BE USED IN LIEU OF WELDED WIRE MESH 4. ALL SLABS ON GRADE SHALL BE 4" THICK WITH FIBERMESH. 5. ALL REINFORCING SHALL CONFORM TO ASTM A615, BE GRADE 60 (60 KSI MIN.) DEFORMED BARS, 43 BARS MAY BE GRADE 40 6. ALL OVER POUR CONCRETE FILLED SUPPORTED SLABS SHALL BE 3000 PSI MIN., 2" MINIMUM. THICKNESS. 7. SOIL BEARING PRESSURE SHALL BE A MINIMUM OF 1500 PSF. 8. THE CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING: OPC (PORTLAND CEMENT TYPE L- ASTM C 150). AGGREGATES - 46 STONE, ASTM C 33 SIZE NO. 67 LESS THAN 3/4" AIR ENTRAINING +/- 1% - ASTM C 260. WATER REDUCING AGENT - ASTM C 494. CLEAN POTABLE WATER. OTHER ADMIXTURES SHALL NOT BE PERMITTED. 9. METAL WELDED WIRE SHALL CONFORM TO ASTM A 185. 10. PREPARE & PLACE CONCRETE ACCORDING TO AMERICAN CONCRETE INSTITUTE MANUAL STANDARD PRACTICE, PART 1, 2, & 3 ALONG WITH HOT WEATHER CONDITIONS RECOMMENDATIONS. 11. IF UTILIZING EXISTING CONCRETE FOR FOUNDATION, CONCRETE SHALL BE A MINIMUM OF 4" IN THICKNESS, VISIBLY FREE OF ANY STRUCTURAL EXCESSIVE CRACKING, SPATTING OR OTHER DETERIORATION. B. MASONRY: J. CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALT, BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR. 2.ALL MORTAR SHALL, BE OF TYPE M OR S. 3.ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 3/8". 4.PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS 5`-0" 1N HEIGHT. C. ALUMINUM: I. ALL STRUCTURAL ALUMINUM SHALL CONFORM TO THE MINIMUM REQUIREMENTS OF 6005-T5 FOR ALLOY WITH A MINIMUM THICKNESS OF 0.040" FOR SUPPORTING MEMBERS. 2. WHERE KICK PLATES ARE USED A MINIMUM THICKNESS OF 0.024" SHALL APPLY. 3. STRUCTURAL ALUMINUM DESIGN CONFORMS TO "PART I -A - SPECIFICATIONS FOR ALUMINUM STRUCTURES - ALLOWABLE STRESS DESIGN" OR "PART I-B - SPECIFICATIONS FOR ALUMINUM STRUCTURES - BUILDING LOAD AND RESISTANCE FACTOR DESIGN' OF THE ALUMINUM DESIGN MANUAL PREPARED BY THE ALUMINUM ASSOCIATION, INC.WASHINGTON D.C. THE FLORIDA BUILDING CODE 77"ff EDITION ( CHAPTER 16 STRUCTURAL DESIGN & CHAPTER 20 ALUMINUM). 4. WHERE ALUMINUM COMES INTO CONTACT WITH STEEL, OR PRESSURE TREATED LUMBER PROVIDE DIELECTRIC SEPARATION. 5. ALUMINUM MEMBERS SHALL BE STITCHED WITH NO LESS THAN #10 SMS 6" FROM THE ENDS AND 12" ON CENTER, IF USING 412 SPACING MAY BE 24" ON CENTER. 6_ VINYL AND ACRYLIC PANELS SHALL BE REMOVABLE. THEY SHALL BE IDENTIFIED WITH A DECAL ESSENTIALLY STATING "REMOVABLE PANEL SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 MPH". DECAL SHALL BE PLACED SO IT IS VISIBLE WHEN PANEL IS INSTALLED. 7. I "X2"X0.045" NON-STRUCTURAL MEMBERS SHALL BE ATTACHED TO HOST WITH 1/4"0 X 1-3/4" EMBEDMENT & 24" O.C. MASONRY SCREW FOR CONCRETE & EQUIVALENT SIZE WOOD SCREW WHEN IN WOOD & #IOX 1/2" EMBEDMENT SMS OR TEK SCREWS IN ALUMINUM MEMBERS TYPICAL. D. FASTENERS: 1, ALL LAG BOLTS SHALL CONFORM TO STAINLESS STEEL TYPE 300 18-8, WITH STANDARD FLAT WASHER UNLESS MANUFACTURER GALVANIZES BOLTS SPECIFIES FOR USE WITH ACQ PRESSURE TREATED WOOD. 2. HEX BOLTS HAS TO BE ASTM A 325, PLATED WITH STANDARD FLAT WASHERS AND NUTS. 3. ALL CONCRETE SCREWS SHALL BE, SIMPSON, HILTI, RAWL, TAPCON, REDHEAD, DYNABOLT, PORTECT OR APPROVED EQUAL. 4, ALL METAL TIES AND ASSOCIATED ACCESSORIES SHALL BE HOT DIPPED GALVANIZED. 5, ALL LAG BOLTS SHALL HAVE A MINIMUM EMBEDMENT OF 8X BOLT DIAMETER INTO STRUCTURAL FRAMING (G=A2 MIN.), 6. LAG BOLTS AND SCREWS INTO WOOD FRAMING SHALL BE PROVIDED WITH PILOT HOLES HAVING A DIAMETER NOT GREATER THAN 70 PERCENT OF THE THREAD DIAMETER OF THE BOLT OR SCREW. ALL LAG BOLTS AND SCREWS SHALL BE INSERTED IN PILOT HOLES BY TURNING AND UNDER NO CIRCUMSTANCES BY DRIVING WITH A HAMMER. 7, ALL EXPANSION ANCHORS SHALL BE DESIGNED IN ACCORDANCE WITH THE SPECIFIC MANUFACTURER'S REQUIREMENTS AND ALLOWABLE LOADS AND SHALL ONLY BE APPLIED IN CONDITIONS ACCEPTABLE TO MANUFACTURER. FASTENERS SHALL BE A MINIMUM OF SAE GRADE #5 OR BETTER ZINC PLATED, 8, ALL FASTENERS CONNECTING ALUMINUM COMPONENTS OR PRESSURE TREATED LUMBER ARE STAINLESS STEEL TYPE 300 18-8, UNLESS MANUFACTURER GALVANIZED BOLTS SPECIFIES FOR USE WITH ACQ PRESSURE TREATED WOOD, OR OTHERWISE NOTED ON PLANS. 9. ALL FASTENERS SHALL COMPLY WITH ASTM A153. 10. ALL CONNECTORS SHALL COMPLY WITH ASTM A653 CLASS G-185. 11, FOR SMS, THE MINIMUM CENTER -TO -CENTER SPACING SHALL BE 3/4" AND MINIMUM CENTER -TO -EDGE SHALL BE 1/2" UNLESS NOTED OTHER WISE. :` l s►lsCl ASTM E 119 ASTM E 1300 CURRENT ASCE 7 CURRENT ALUMINUM DESIGN MANUAL -AA ASM35, AND SPEC. FOR ALUMINUM PART I -A, & I-B ASTM C94 ASTM C150 ASTM C33 ASTM C260 ASTM C494 ASTM A615 ASTM A185 FLORIDABUILDING CODE 7THEDITION (CHAPTERS 16,20 & 23). THE FOLLOWING LIST OF ABBREVIATIONS IS NOT INTENDED TO REPRESENT ALL THOSE USED ON THESE DRAWINGS, BUT TO SUPPLEMENT THE MORE COMMON ABBREVIATIONS. I. TYP --TYPICAL 2. SIM -- SIMILAR 3. UON -- UNLESS OTHERWISE NOTED 4, CONT-- CONTINUOUS 5. VIE -- VERIFY IN FIELD G. RESPONSIBILITY: 1. ALL SITE WORK SHALL BE PERFORMED BY A LICENSE',D CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDINANCES, ETC. 2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND DETAILS, NOTIFYING ENGINEER OF ANY DISCREPANCIES BETWEEN DRAWINGS, FABRICATED ITEMS, OR ACTUAL FIELD CONDITIONS, 3. THESE DRAWINGS REPRESENT THE ACCEPTABILITY OF THE 'SUNROOM' ROOM ADDITION ELEMENTS AS PROVIDED BY THE CONTRACTOR. 4. ALL DETAILS ON THESE DRAWINGS ARE ENGINEERED BASED ON INFORMATION PROVIDED BY THE. CONTRACTOR AND MANUFACTURER. 5. ANY DETAILS NOT SHOWN ARE TO BE ENGINEERED BY A LICENSED P.E. IN ACCORDANCE WITH STANDARD ENGINEERING PRACTICES. H. MISCELLANEOUS: 1. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME. IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPARATE 4TH WALL SUPPORT SYSTEM MUST BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. 2. IF ENCLOSURE CONTAINS A SWIMMING POOL OR SPA, THE ENCLOSURE SHALL COMPLY WITH RESIDENTIAL SWIMMING BARRIER REQUIREMENTS OF THE FBC 7THEDITION R 4501.17 IN ITS ENTIRETY. 3. DOOR LOCATIONS MAY BE DETERMINED IN THE FIELD BY CONTRACTOR. 4. IF PAVERS ARE UNDER ALUMINUM MEMBERS THEY SHALL HAVE EPDXY ADHESIVE TO CONCRETE OR IF USING GROUT, ENSURE BONDING AGENT IS USED FIRST AND ADHERED WITH MINIMUM 3000 PSI GROUT. 5. SCREENING MATERIAL, SHALL BE 18XI4X0.013 OR EQUIVALENT DENSITY SCREEN MESH ONLY UNLESS NOTED ON DRAWING S-2, DESIGN DATA: 1. ULTIMATE DESIGN WIND SPEED Vult, (3 SECOND GUST): NOMINAL DESIGN WIND SPEED Vasd: 2. RISK CATEGORY: 3. WIND EXPOSURE: 4. WIND LOADS: SCREEN ROOF: N/A SCREEN WALLS: 23 PSF SOLID ROOF (SCREEN WALL): 20 PSF ENGINEER OF RECORD: David W. Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson P. 130MPH 101 MPH FLORIDA LICENSE: 38654 Myron Max Neal P.E. FLORIDA LICENSE: 86663 5. FACTOR APPLIED TO SCREEN WIND LOADS FOR I8X14XO.013 OR EQUIVALENT DENSITY SCREEN MESH: 0.88 6. FACTOR APPLIED TO SCREEN WIND LOADS FOR ALLOWABLE STRESS DESIGN: 0.6 7. LIVE LOAD: 300 ib. VERTICAL DOWNLOAD ON PRIMARY SCREEN ENCLOSURE MEMBERS. 2001b. VERTICAL DOWNLOAD ON SCREEN ENCLOSURE PURLINS. 10 :SF VERTICAL DOWNLOAD ON SOLID ROOF. 8. PROPOSED KX8" W/ (1) A 5 REBAR W/ 25" OVERLAP ON 3" CHAIRS W/ 4" MONOLITHIC SLAB W/ FIBER -MESH FILLED W/ 3000 PST SHALL BE ADEQUATE TO RESIST" THE UPLOADS FOR THE PROPOSED STRUCTURE. 9. SCREEN ROOF TYPE: N/A 10. SOLID ROOF TYPE: 3"X48"X0.024" ELITE EPS COMPOSITE PANEL ROOF 21b FOAM DENSITY, FLORIDA PRODUCT APPROVAL, FL 7561-R50R EQUIV. # * 1 2 x 2:--------------------------------------2" x 2" x 0,044„ 2 x 3:--------------------------- 2" x 3" x 0.050„ 2 x 4:---------------------------------------2" x 4" x 0.050„ 2 x 5:---------------------------------------2„ x 5" x 0.050„ 3 x 3:---------------------------------------3" x 3" x 0.125" OPEN BACK SECTIONS 1 x 2:---------------------------------------- 1" x 2" x 0.040" 1 x 3:----------------------------------------1" x 3" x 0.045" 2 x 2 SMS:----- -------- - ---------2" x 2" x 0.045" 2 x 3 SMS: ---------------------------------2" x 3" x 0.072" 2 x 4 SMS:--------------------------------- 2" x 4" x 0.045" 3 x 3 SMS:--------------------------------- 3" x 3" x 0.090" INDEX: S-1 GENERAL NOTES S-2 DRAVVING S-3 DETAILS S-4 DETAILS REVIE W D, C171-Y OF PLAN EXAMINER SELF MATING (SMB) p; E , .f .� '� Ate,, ,. 2 x 4 SMB:--------------------- 2" x 4" x 0.044" x 0.100" DES FLORIDA L I 1, rF " -R 2 x S SMB:----------- -- 2" x 5" x 0.050" x 0.11.8" ate.. 2 x 6 SMB:---- -- - - 2" x 6" x 0.050" x 0.120" NlAnONAL ELECT, RIC CODE, 2 x 7 SMB:------------- - 2" x 7" x 0.057" x 0.120" AND THE C111Y ` �F ZEPH -HILL S2 2 x 8 SMB:---------------------- 2" x 8" x 0.072" x 0.224" ORDINANCES 2 x 9 SMB:---------------------- 2" x 9" x 0.072" x 0.224" 2 x 10 SMB:------------------- 2" x 10" x 0.092" x 0.374" TUBE SECTIONS 2 x 2:-------------------------------------2" x 2" x 0.090" Joel Falardeau P.E. FLORIDA LICENSE: 70667 Erik Stuart P.E. FLORIDA LICENSE: 77605 Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 Ph#(813)788-5314 Fax# 1-(866)824-7894 E-maiI-erb@fbcplans.com Website-www.fb cplans. corn C.O.A.-429054 DATE: 01/10/2022 REVISION: I DATE: IR01 RO 2 RO 3'- RO 4 I I �i ' � IN 3 WAGON TRAIL ST HYRHILLS, FL 33541 —0, 1 x2 PROPOSED 8"X8" FOOTING W/ (1) # 5 REBAR W/ 4" MONOLITHIC SLAB S-4 ATTACH TO WALL II III I III 3"X48"XO.024" O LB FOAM! COMPOSITE PANE ROOF MINJ II SLOPE PER 11 II II III i III I rs 2x3P-E9GE- BM 21'-0" 2 3'- 0 " JilII I III III III Il JA 11 II I II III :S - 3: 1 1 7 —0, 1x2 (P) 0 0 ;F-NS, 8654 optx'o '00 'S�'SiONO, O'N ENGINEER OF RECORD: David W. Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson P.] FLORIDA LICENSE: 38654 Myron Max Neal P.E. FLORIDA LICENSE: 86663 Joel Falardeau P.E. FLORIDA LICENSE: 70667 Erik Stuart P.E. FLORIDA LICENSE: 77605 FBC Plans & Engineering Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 Ph# (813)788-5314 Fax# 1-(866)824-7894 E-mail-erb@fbcplans.com Website-www.fbcp1ans.com C.O.A.429054 DATE: 01/10/2022 REVISION: I DATE: RO 1 RO 2 RO 3 RO 4 Job# 220110129 * J) f ZERS S LERCH 6533 WAGON TRAIL ST ZEPHYRHILLS, FL 33541 ILI I iM., UPRIGHT SECONDARY ANGLE MIN S L (4) #10 X 3/4" SMS 0.125" THICK (NOT ..a-ago -0 go 0% ALUMINUM RISER PAN FASTENING SECONDARY ANGLE TO COLUMN (TYPk SIDE) /REQUIRED FOR 2X3 MEMBER) R) a a EACH PRIMARY 2" X 2" #12 SMS W/ 1 "0 NEO-WASHERS (4) #12 SMS W/ 3/4' 8" O.C. (USE SCREW LENGTH WASHERS PER 12" PANEL I (B) -CONCRETE SCREW ANCHOR INTO SECONDARY I X 0.125" ANGLE (2) #10 X 3/4" SMS FASTENING a -TpNE OF EQUAL TO COMPOSITE PANEL THICKNESS PLUS (1) INCH) _UMN ANGLECTYP EACH SIDE) (SEE I - 0 (Y TABLE) 0 TO PRIMARY ANGLE (TYP EACH SIDE) S a 40 a 41 4. fkV0 OPTION #1 SEE DETAIL C2 FOR ALUMINUM RISER PANS Detail C2 (4)#10 x 1 Z" SMS INTO SCREW BOSSES OPTION #2 0 RECEIVING CHANNEL ANCHOR /—OR ANGLE EA. SIDE (typ) (MIN) (TYP)(SEE TABLE) (,0625" THICKNESS) T - 3" (MIN) X 2" BASE MEMBER (TYP EACH SIDE) (1) - CONCRETE SCREW (SEE TABLE) ANCHOR INTO PRIMARY ANGLE AND @ 1/4" 0 CONCRETE SCREW ANCHOR @ 24" O.C, BETWEEN COLUMNS Q, ..*00.000 10 lk� '0 "f I A� Ro �SEAL F5R6f ENGINEER UV RECORD. David W. Smith P FLORIDA LICENSE: 53608 2"X2" OR 2"X3' (2) #10x 3/4" SMS (2) - 3/8" 0 MACHINE OPTIONAL 1" X 2" FASTENED PURLIN OR GIRT (typ) EA. LEG) QTOTAL BOLTS WITH 3/4 TO COLUMN WITH (2) #10 X 2' 6 SCREWS R.C. (8) 3 WASHERS THROUGH I SMS INTO SCREW BOSSES SCREWS ANGLE EA. CONNECTION) POST AND EDGE BEAM 'M AND FASTENED TO EDGE BEAM WITH (1) #10 X 1-1/2" SMS WITHIN 6" OF COLUMN CONTINUOUS EDGE BEAM AND AND @ 12" O.C. MAX i POST PURLIN OR GIRT TO BEAM OR POST DETAIL NOTE: EDGE BEAM (SEE SHEET S-2 FOR SIZE) SHALL BE ORIENTED IN DIRECTION SHOWN. �S-3 SCALE:NTS) Column Size 1/4"& 3/8"0 Concrete Screw Anchor B Min. Spa 2x3-1/4" 0 011 2x4-1/4" 1 3" 1 2x5-1/4" 1 3" 2x6-3/8" 1 4" 2x7-3/8" 1 5" 2x8-3/8" 2 3" 2x9-3/8" 2 4" NOTES: (' Y, EACH SIDE) 1. NUMBER OF ANCHORS "B" IS EACH SIDE INTO THE SECONDARY Thomas L. Hanson P.E ANGLE AND DOES NOT INCLUDE THE ANCHOR INTO THE 1X2. FLORIDA LICENSE: 38654 2. MINIMUM EMBEDMENT OF ANCHORS INTO CONCRETE FOOTING SHALL BE 2-3/4" AT AT ALL UPRIGHT LOCATIONS. ALL SCREW Myron Max Neal P.E. LENGTHS AT UPRIGHT CONNECTIONS SHALL BE OF SUFFICIENT FLORIDA LICENSE: 86663 LENGTH FOR REQUIRED EMBEDMENT INTO CONCRETE FOOTING WHEN A PAVER DECK IS PRESENT. Joel Falardeau P.E. 3. CONCRETE SCREW ANCHOR DESIGNS ARE BASED ON THOSE LISTED FLORIDA LICENSE: 70667 ON S-1, D. FASTENERS, OTHER BRAND & TYPE SHALL BE APPROVED BY ENGINEER. I Erik Stuart P.E. 4. 2X3W/1X2 CORNER POST SHALL REQUIRE SAME BASE CONNECTIONS AS 2X4 SHOWN IN TABLE. FLORIDA LICENSE: 77605 S. IF FOR AN IN -FILL, TOP OF COLUMN CONNECTION SIMILAR IF S CONCRETE LINTEL. IF WOOD LINTEL SUBSTITUTE 1/4"0 X 3" LAG FHC Plans & Engineering ROOF PANEL TO EDGE BEAM CONNECTION DETAIL SCREW FOR 3/8"0 LOT FOR BOTH PRIMARY & SECONDARY ANGLES. Services, Inc. �S-3 SCALE: 6.2X2X045 DOOR JAMB MEMBER SHALL CONNECT SIMILAR TO 2X3 MEMBER. 6272 Abbott Station Dr. Unit 101 2" x 3" OR LARGER UPRIGHT TO CONCRETE W/WO PAVER DETAILS Zephyrhills, FL 33542 SCALE:NTS Ph# (813)788-5314 Fax4 1-(866)824-7894 - ------ E-mail-erb@fbcplans.com Website-www,fbcplans.com CO.A,429054 DATE: 01/10/2022 HINGE LOCATION—­ BREAK FORM HEADER OR DRAWN BY: ST ECEIVING CHANNEL 2" x 2" EXTRUSION— 2" x 2" EXTRUSION #10 SMS AT EACH RISER REVISION: DATE: FOR PAN OR #10 SMS @ EXISTING MASONRY RO 1 8" O.C. FOR COMPOSITE PANEL WALL GROUTED HINGE LOCATION— DOOR SOLID @ CONNECTION RO 2 SOLID ROOF 00 RO 3 00 RO 4 1/4"0 X 2-1/2" Job# 22 0110 129 MASONRY SCREW 3" FROM 2" x —END BEAM END & @ 24" O.C. PROJECT ADDRESS: HINGE LOCATION—j�� 4 (SEE SHEET S -2 FOR SIZE) 4 i LERCH #10 SMS @ 8" O.C. 2" x 2 " x 1/8" x BEAM DEPTH" 6533 WAGON FOR COMPOSITE PANEL I RECEIVING CHANNEL ZEPHYRHILLS, FL 33541 NOTES: (4) #10 SCREWS PER 12" W/ (1) 1/4" x 3" CONCRETE 1`12" OPEN BACK 1. HINGES SHALL BE ATTACHED TO STRUCTURE W/ (4) #10 x 5/8" SMS MINIMUM. IDTH CONNECTING ANCHOR INTO WALL & (4) #10 x 3/4" SMS EACH 2. DOOR SHALL BE ATTACHED TO ENCLOSURE w/(2) HINGES MINIMUM. PAN TO HEADER (BOTTOM OF PAN) SIDE INTO BEAM CONTRACTOR: 3. HINGES SHALL BE ATTACHED TO DOOR WITH (3)#10 x 5/8" SMS, FASTEN NOTE: WHEN ATTACHING TO WOOD STRUCTURES, WOOD LAG SCREW NO PATRIOT SCREENS, INC. I" x 2" x 0.044" TO UPRIGHT W/#12 x 1" SMS @ 12" O.C. AND WITHIN 3" FROM 1/4"13" MASONRY ANCHORS 24" O.C. ANCHOR DESIGNS SHALL BE OF IDENTICAL SIZE AND EMBEDMENT AS THAT END OF THE UPRIGHT. (2) ROWS STAGGERED CONNECTING 1 OF MASONRY ANCHOR SCREWS. HEADER OR CHANNEL TO HOST, S2"END BEAM TO HOST STRUCTURE DETAIL F TYPICAL SCREEN DOOR CONNECTION DETAIL I rsf ROOF PANEL TO WALL CONNECTION DETAILS SCALENTS �S-3 S-3 SCALE:NTS �S-3 SCALE: NTS DETAILS 4 n l 7 / 1/4"0 x 2"-1/2 MASONRY ANCHOR I / IF WOOD SUBSTITUTE IDENTICAL WOOD SCREW OR LAG 6" FROM / TOP & BOTTOM & @ 24" O.C. / I x2"OPEN BACK li V / I/ y Vx2"OPEN BACK (2) #10 x 1-1/2" EMS MIN THRU SCREW BOSS OF 1"12"OPEN BACK OPEN BACK TO HOST STRUCTURE DETAIL SCALE:NTS #12 SMS W/ 1"0 NEO- WASHERS @ 8" O.C, (USE SCREW LENGTH EQUAL. TO COMPOSITE PANEL THICKNESS ALUMINUM RISER PAN (4) #12 SMS W/ 3/4" WASHERS PER 12"PANEL D?Tail C2 (4) - 3/8" 0 CONCRETE NOTE:MINIMUM EMBEDMENT OF ANCHORS INTO SCREW WITH 2-3/4" CONCRETE FOOTING SHALL BE 2-3/4" AT ALL EMBEDMENT (MIN EDGE POST LOCATIONS. ALL SCREW LENGTHS AT POST DISTANCE FROM DECK CONNECTIONS SHALL BE OF SUFFICIENT LENGTH EDGE=3" _ _ FOR REQUIRED EMBEDMENT INTO CONCRETE MIN SPACING 411) FOOTING WHEN A PAVER DECK IS PRESENT. (H) -3/8" 0 MACHINE BOLTS WITH WASHERS — — OR (HH) #14X 3/4 SM (MIN. EDGE DISTANCE = 1" TOP VIEW MIN, SPACING= 2") 0 Z PER PLAN (H) (HH) 3"0"/4" x 4' (2) (4) 6" x 6" (3) (6) 3"0"x 0,125" ANGLE (EXTERNAL OR INTERNAL) OR 0.125" RECEIVING CHANNEL (4) - 3/8" 0 CONCRETE ) `t/ SCREW WITH 2-3/4" I ' 1" x 2"' OPEN BACK ANCHORED EMBEDMENT[ EDGE ALUM. TO CONCRETE w/ 1/4" X 3- DISTANCE FROM DEC POST" 1/2" MASONRY ANCHOR - 6" EDGE=3" 6„ MAX EACH SIDE OF POST AND 46 MIN SPACING 4") 24" O.C. MAX d 4 a - - FASTEN .090 REC. CHAN. TO BACKSIDE OF 2"XH" EDGE BEAM SEE DETAIL C2 FOR WAS) #10 SMS W/ 3/4" ALUMINUM RISER PANS STAGGERED W/(H) #10 SMS W/ 3/4" INTO SIDE FLANGES g 2X(H) ® EDGE Oa BEAM ?LY EDGE BEAM W/ REC. CHANNELS ® ® NOTCHED POST FASTEN .060 REC. CHAN. TO UNDERSIDE OF ZX_ EDGE BEAM W/(4) #10 SMS W/ 3/4" CONTINUOUS EDGE BEAM POST STAGGERED W/(2) #10 SMS W/ 3/4' INTO SIDE FLANGES NOTE: EDGE BEAM (SEE SHEET S-2 FOR SIZE) SHALL BE ORIENTED IN DIRECTION SHOWN, REC, CHANNEL.060 MIN., SAME WIDTH AS BEAM TYP. ROOF PANEL TO EDGE/END BEAM CONNECTION ALT. DETAIL SCALE: NTS r r I . 4" (min) FRONT VIEW NOTE: CONCRETE SCREW ANCHOR DESIGNS ARE BASED ON TITEN HD 3/8" 0 SCREW ANCHORS, OTHER SIZE OR TYPE OF ANCHORS SHALL NOT BE USED. NOTE: FOR PATIO COVERS AND CARPORTS: DISREGARD THE 1X2 OPEN BACK SCREEN MEMBER ON THE FOUNDATION TYP. Cg1 ALUM. POST CONNECTION DETAIL S_ SCALE: NTS 1wilEw UPRIGHT OR BEAM KICK PLATE • -SNAP OR SELF ATTACHED TO ALUMINUM MATING OR MEMBER W/ (1) #1DX HOLLOW 3/4"@ 24" O.C. KICK PLATE ATTACHED TO ALUMINUM MEMBER SCALE: N'rS `.. � 0 0 I% PRb E -, , ! TENEER SEAL ENGINEER OF RECORD: David W. Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson P.E FLORIDA LICENSE: 38654 Myron Max Neal P.E. FLORIDA LICENSE: 86663 Joel Falardeau P.E. FLORIDA LICENSE: 70667 Erik Stuart P.E. FLORIDA LICENSE: 77605 FBC Plans & Engineering Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 Ph# (813)788-5314 Fax# 1-(866)824-7894 E-mail-erb@fbcplans.com Website-www.fbcplans.cozn C.O.A.429054 DATE: 01/10/2022 i' REVISION: DATE: RO 1 RO 2 RO 3 RO 4 �— Job# 220110129 PROJECT ADDRESS- LERCH s . ON EEPHYRHILLS,