HomeMy WebLinkAbout22-3517REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for irvnr-.*vemen - meft. If vou itte-t.4.44 obtain fina before recording your notice of commencement." Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNATURE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 925 INSTR#2022024579 OR BK10539 PG Page 1 of 1 01/27/2022 04:42 PM Rcpt: 2409329 Rec: 10.00 DS- 0.00 IT: 0.00 Nikki Alvarez-Sowles, Esq,, Pasco County Clerk & Comptroller Permit Number FollofflarcelID a 14-26-21-0170-000 Prepared by. M6M­ENTUM SOLAR I IVIchelie ffifen a — 6'210 Hoffner Ave, Ste 100 Orlando FL 32&V tclrTt toe Q 6 M R 610 r a. 10 Orlando FL 32622 NOTICE OF COMMENCEMENT State of Florida, County of - Pasco The undersigned hereby gives notice that Improvement wili be made to certain real property,, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice. of mmencement. I . Description of property (1,T., I descrilpon of the party, and street address If available)38752 FEATHERING WAY 2. General description of Improvement installation of photo voltaic solar panels on rooftop 1 Owner InformationiP Information D AddressName RICARDO k Interest In perName and address of fee simple titleholder (if different from Owner listed above) Name NiA a Telephone Number 321-247-6073 aSurety (li appll bla, a copy of the payment bond is attached) Name WA Telephone Number Address Amount of Bond 6. Lender Name WA Telephone Number Florida7. Persons wk'nln the State of kt b Owner uponor other documents be served as provided by §713,13(l)(a)7, Florida Statutes. INIA Telephone Number addition to himself or herself, Owner designates 4.'a' following. the Lienor's providedNotice as Y Name — N/A Telephone Number Address , ,,y 9 Expiration date of notice of expiration ;1 specified)unless a different date Is WARNING TO OWNER. ANY PAYMENTS ' BYTHE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT l: CONSIDEREDARE RESULT IN YOUR PAYING TWICE FOR impRovENIENTs To YOUR PROPERTY. A No-"CE OF COMMENCEMENT MUST BE RECORDED AMD POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOU �O ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. a The foregoing instrument was acknowledgedN ,,' physics' ; . ine notarization, this 20 day of Jan / 22 _by RICARDO o .. , ,... A.00 rnonth r norne of person as Owner for Type of au#xW, owner,rtee, attorney In fad me of party an beW of whom ant was executed Personally Known ____PR Produced ID X — I No 0?" AKI raw Eq ca *"N iTAT E OF FLORIDA, COUNTY OF PASCO THIS IS TO CERTIFY THAT THE FOREGOING IS A FRUE AND CORRECT COPY OF THE DOCUMENT ON FILE OR OF PUBLIC RECORD IN THIS OFFICE WITNESS MY HAND A OFFICIAL EALT� �l DAY OF N I K K I Ai E ES, ERK & COMPTROLLER -DEPUTY CLERK 81J_1bU_002o City ot Zephyrhills Permit Application Building Department I Date Received 1/21/2022 Phone Contact for Permitiml 4�� 321 247 - 6073 Owner's Name RICARDO AROCHO Owner Phone Number (321) 247-6073 Owner's Address 38752 FEATHERING WAY FL 3354 Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 38752 FEATHERING WAY ZEPHYRHtLLS FL 33542 LOT # 15 SUBDIVISION PARCEL ID# 14-26-21-0170-00000-0150 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED FT­1 NEW CONSTR ADDIALT SIGN DEMOLISH INSTALL REPAIR PROPOSED USE SFR COMM OTHER TYPE OF CONSTRUCTION BLOCK FRAME STEEL DESCRIPTION OF WORK INSTALLATION OF PHOTOVOLTAIC SOLAR PANELS ON ROOFTOP BUILDING SIZE Set FOOTAGE HEIGHT =BUILDING 27,404 VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL AMP SERVICE PROGRESS ENERGY W,R,E.C. =PLUMBING =MECHANICAL 1$ VALUATION OF MECHANICAL INSTALLATION =GAS ROOFING SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY Momentum Solar SIGNATURE Cameron REGISTERED �Y/ N Momentum Solar CURREN �11 N Address License # [KV=C57036 ELECTRICIAN COMPANY Momentum Solar -Matthew Franz REGISTERED Y/N FEE CURREN Y/N SIGNATURE �1� D Address 6210 Ho Ave Ste 100 Orlando FL 32822 License # PLUMBER COMPANY E SIGNATURE REGISTERED YIN FEE .11�RRENY / N�� Address F_ License # MECHANICAL COMPANY SIGNATURE REGISTERED �FEEC.RREN( N�� Address E========== License # OTHER COMPANYL==— _FEE C_URREN_=N:]_� SIGNATURE REGISTERED Address License# RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Storrawater Plans wl Silt Fence installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & I dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans, ****PROPERTY SURVEY required for all NEW construction, Directions: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (A/C upgrades over $7500) Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage) Driveways -Not over Counter if on public roadways -needs ROW 813-180-0020 City of Zephymills Permit Application I-ax-613-M-002I Building Department NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions, UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law, If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not property licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500,00 or more, I certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the 'owner" prior to commencement, CONTRACTOR'WOWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. Southwest Florida Water Management District -Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers -Seawalls, Docks, Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency -Asbestos abatement. Federal Aviation Authority -Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone W" unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida, If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties, If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. FLORIDA JURAT (F.S. 117,03) OWNER OR AGENT Subscribed and sworn to (or affirmed) before me this by Who is/are personally known to me or has/have produced as identification. Commission No or Public Subscribed and sworn to (or affirmed) before me this 1aj2Q22_b Who War _ersonal or has/have produced as identification. RIM or 4%" Ot a Notary Public State of Florida P .4�, � Lauren E EI-Taher My Commission GG 298001 "Ile Expires 02/04/2023 EEI vl N" "o V momentum WAKAM City of Zephyrhills Building Department 5335 8th SL Zephyrhills, FL 33542 RE: Permit revision for ELCMISC-003517-2022 Dear Plans Examiner, M 0 KW. Please let us know when this revision is approved. 92= Yal �A&' Julia Urbanski 321-247-6073 flpermits@Momentumsolar.com 3096 B Hamilton Blvd. South Plainfield, NJ 07080 Daniel W. Dunzl*k I Architect LEED-AP ---- --- -77- 908-872-3664 370 Burnt Hill Rd. Skillman NJ. 08558 StudioGdesign*comeast.net January 12, 2022 Re: Proposed Photovoltaic Solar Panel Installation Ricardo Hernandez Arocho 38752 FEATHERING WAY ZEPHYRHILLS, FL 33542 Dear Plan Reviewer: Certification: I have reviewed the engineering testing reports for the racking and attachments to be used on this project and I certify that the products are capable of supporting the code required loads and are suitable for this installation when installed in strict compliance with the manufacturers printed instructions. Regarding the solar panel array installation on the above referenced project please note that an inspection was performed by a representative of the Architect/Engineer of Record, and analysis of the existing structure was conducted. There is adequate structural capacity for the installation of the array with the following recommendations: 1. The array will be installed on the existing roof. The roof framing is constructed of 2"x4" wood trusses @)24" o.c. spanning 16' 3" with a top chord length of 17' 3" with intermediate supports at 1/3rd points, making the effective longest span equals 5' 10" with 1/2 " OSB plywood sheathing, The new array (See Site map by contractor) will add 2,63 Lb. / Sf. overall to the roof. The existing structure is sufficient to support the new loads associated with the additional weight & wind resistance. No additional structural support is required for the roof structure. 2. The attachment system shall be secured to the roof and shall be in strict compliance with manufacturers printed instructions. The attachment system shall be UL 1703 approved tested. Provide 6 mil, vapor barrier between dissimilar metals. Provide water tight gasket and sealant at all penetrations. Attachments shall follow panel rows as specified by the system manufacturer's installation manual. The panel angle shall match the roof slope. Reference summary table below: ER2o2L12SLShingle Fastener Max Spacing (in.) 1 At!22h222!!LS Strri: IT",1c . "ROOFTEC"RT MINI II" & "Ecol'asteii" Click HOP Attachement Systems Wind Zone I Wind Zone 2 Wind Zone 3 Fastener Info: min. 5/16" x 4" long stainless -steel lags with a min. 48 32 -T-32 embedment of 3" into the rafters 3. Solar Modules shall be UL- 1703 rated. Refer to manufacturers specifications sheets. 4. Positive drainage of the system shall be so as not to void the existing roof warranty. 5. All aspects of the installation shall comply with the Florida Administrative Code, 2020 Florida Building Code - Residential Seventh Edition, ASCE-7-16, 2020 Florida Building Code — Energy Conservation, Seventh Edition, 2017 National Electric Code, All Local Governing County and Municipal Ordinances adopted by reference or enacted by law. All components used meet the criteria of the Florida Solar Energy Center, 6. Please refer to the attached structural calculations, _rfY77?'., If you have any questions relating to this matter, please Daniel W. Dunzik, RA. LEER -AP FL. Lic. No. AR98795 y671h, rivenience. Thank you. over \M A o,87 EDP�' Daniel W. ® Architect LEER -AP 370 Burnt Hill Rd. Skillman NJ. 08558 908-872-3664 StudioGdesign(a,)comeast.net January 12, 2022 Gravitv Load Calculation Criteria Structural Design Loads per ASCE 7-16 Dead Loads = 10 psf + 2.6 psf (new solar panels) = 12.6 psf Roof Live Load = 20 psf Ground Snow Load/Live Load = 0 psf Wind Load Calculation Criteria Wind Loads per ASCE 7-16, Equation 29,4-7 Using an effective wind area of 10 SF, external pressure coefficient from Figure 30.3 -A-1 Zone I = -36.5 psf Roof Slope = 20 degrees Roof Mean Height = 15 ft Zone 2 = -47.4 psf Basic Wind Speed = 140 mph Zone 3 = -54.7 psf Exposure = B Per section 2.4.1, ASD combo = D + 0.6W: Zone I = 2.6 psf + 0. 6(-3 6.5 psf) = - 19.3 psf Zone 2 = 2.6 psf + 0.6(-47.4 psf) = -25.8 psf Zone 3 = 2.6 psf + 0.6(-54.7 psf) = -30.2 psf Check Attachment to Wood Truss Use 5/16 dia. Lag screw w/ 3" embedment into 2 in. wide roof rafter Lag Screw Spacing: Lag Screw Tributary Area: Zone I = 48" o.c. max Zone I = (48" o.c. max)^2 J 144 = 16 SF Zone 2 = 32" o.c. max Zone 2 = (32" o.c. max)^2 1144 = 7.11 SF Zone 3 = 32" o.c. max Zone 3 = (32" o.c. max)2 1144 = 7.11 SF Lag Screw Forces: Zone I = 193 psf x 16 SF = 309 lb < W', OK Zone 2 = 25.8 psf x 7.11 SF = 183 lb < W', OK Zone 3 = 30.2 psf x 7.11 SF = 215 lb < W', OK W = 266lb/in (Table 12.2A, 2015 NDS) Cd = 1.6 (Table 2.3.2, 2015 NDS) Ct = I (Table 2,3.3, 2015 NDS) W'= W x embed x Cd x Ct W'= 266 lb/in x 3 in. xL6 x I = 1276.8 lb N sted 2020, 040032587 O.ANTUM, TECHINOLOGY:LLOW LEVELISED COS' OF ELECTRICni-Y Higher yield per surface area, lower BOS costs, higher Power classes, and an efficiency rate of up to 19.8%. , l_1, 1NNOVATIVE ALL-WEATHER TECt-WOLOGY I—e , C i.'_ I' Optimal yields, whatever the weather with excellent low -light and temperature behaviour. ENDURING HIGH PERFORMANCE V Long-term yield security with Anti LID Technology, Anti PID Technology', Hot -Spot Protect and Traceable Quality Tra.QTm. EXTREME WEE T HIE R krOF 1 N G High-tech aluminium alloy frame, certified for high snow (5400 Pa) and wind loads (4000 Pa). A ME11ABLE 1INVESTMENT Inclusive 25-year product warranty and 25-year linear performance warranty'. STATE OF TIHE ART MODULE TECIIHINOLOGY ( 1% Q.ANTUM DUO combines cutting edge cell separation le C= and innovative wiring with Q.ANTUM Technology, APT test conditions according to IEC/TS 62804-1:2015, method B (-1500 V, 168 h) See data sheet on rear for further information. THE IDEAL SOLUTION FOR: 69 Rooftop arrays on residential buildings Engineered in Germany OCELLS Former 1740mm a 1030 mm x 32 mm (including frame) - Weight ... 199kg vaomm----- -- Front Cover 3.2mm thermally pre -stressed glass with ...... anti reflection technology __. _ zraEa mm a.orouams a+mrneasmm �� Back Craver Composite film I=remst _ Black anodised aluminium CeL` 6 x 20 monocrystalline Q.ANTUM solar half cells ioaomm junction box 53 101 mot x 32 60 man x 15 18 mat Protection class IP67, with bypass diodes r.e� I _{. {-a„�mm - Caddo 4mmaSol arcable; Fr) >1150mm,{ )e1150arm CaP,nectcr St6ubll MC4, IP68 1 A.rnonrre..ar.air- A) T ..I cla- C Iaamm EL,E.t„s t IR11 »ekar€.,, .„anf'1tTMYP'd:.0 S RI t )itineS POWER CLASS .._.. ......... ...... ...... 335__ ,..... 340. 345 356... MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC.' (P0VgER T0I_ERANC)E +6 W !-0 W) PoweratfvtPP' PMpa [Wj 335 340 345 350 Short Ci 11 € cut t CTur 11 €arty I [A] 10 34 10-40 :L0.45 10.51 za Open Circuit Vcita e 9 Voc I444 __ _ ..� . .......... ... ... 95 4121 ., IV) ° Cc rent at force larr A 985 990 Volta qra at M P P veff [V] 34.01 34.34 34.65 34.97 Eff€ciency' q IN a18.7 _>19.0 >_19.3 z19.5 klIN€EL7UrtA pERPORI,IANCE A'r KiOR'MAL L PERAT€NO CONC)ISiONS, NMOT� ... -... -_- Power at inPP poll [Wj 250.9 254.6 268.4 262.1 "."............. _ ._ ....._ . ..-_ ..a..._. ._ .. ... ....... E Short Circuit Current .. Isc [A) 8,33 8.38 8.42 8,47.. F Open Circuit Voltage .., Voo....[Vj 38.13 38.38 38.62 38.86 ., .._ .......... ..... _ ......,_,...._............... .. .. ,,........, ,,.. .. ..._ ............ ,.. „ ....._.......... "i Currant stMPP Iwp, [A] 7,76 7.79 7.84 7.88 Voltage atMPP VA,pe IV] 32.36_ . 32.67 32.97 33.27 ......" ..._. _.. _ ._.......... .. _ ............ .... . ,.... .. ,. 'Measurement tolerances P,,p+3% I,o, Von z5%at STC 1000 W/m°, 25+2'C, AM 15 according to IEC 60904-3 •'800 W(mi, NMOT, spectrum AM 15 ------- Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE ,., as m, na At leasf 98 % of roundlet power our =r r, r C _ �_._r� Ing first year. Thereafter max. 0,54% a ' 1 degradation per year. At Is 93.1 % ), f f onomil napower up to 10 years. At a least 85 % of nominal power up to A' `: i x 26 years. All data within measurement toler- ances. Full warranties in accordance ®a Q e kP®4e00 with the warranty terms of the a 4ao a0 it" o „ _ Q CELLS sales organisation of your RRAPt-ol foor'? zo respective country_ rams Typical modulo performance under low irradiance conditions in comparison to STC conditions (25'C, 1000Wlm'). TEMPERATURE COEFFICIENTS Terupersture Coefficient of I_ a [%/K] +0 04 Telorpersoure Coefficient of tnr, B [%/K] -0.27 Temperature Coefficient of car, _ . y .. [%/K] ..�� 0.35 Nora@reel Module Operating Temperature NMOT [°C] 43+3 PROPS TTS FOR SYSTEM DESIGN Pr1aximum System Voltage Vs,,, _ [V]. 1000.... PV m alum classification Class It IySexirnurn Reverse Current .. .. ,. _. ._ . _. --- . .- __........ .... . .. ..._._._ (e (Al 20 Fine pa°leg tsaaen on ANSI t ILL 61730 CITYPE 2 Max. Dosig=n Load, Push! Roll [Pa] Max. Test Lose, push! Pith [Pa] VDEDustily T t d, !EC 61215-2016; iEC 61730:2018_ This data sheet .oahch s n7vaA t CE with DIN EN 50380_ ,o cv- ir,zsoe, 3600/2667 Perm tted Y+4exiuie Temperature-40'C-+85°C 54DO/ 4000-... on Continuous Duty PACKAGING INFORNIATI10N Hori' anfal 1780mm 1080mm 1208mm 673.8kg 28 pallets 26 pallets 32 modules Vertical 1815mm 1150mm 1220mm 683kg 28 pallets 24 pallets 32 modules Pia#®: rao"Mr., rstn,ct ono must be Widened, See the onto--iatlon and operating rhnual or contact our technical service department for further information on approved inattiletran and use of this product Q CELLS supplies sofa, modules In two different rocking methods, depending on the roation of manufacture (modules are packed hrih-iaity or vertically)_ You can find more detailed informatior. Ir, the document `Packaging and Transport intarmetion avainbie from Q CELLS. Hanwrha ® CELLS GmbH Sonnenallee 17-21, 06766 Bitterfeld-Wolfen, Germany I T.EL+49 (0)3494 66 99-234441 FAN+49 (0)3494 66 99-230001 EMAIL saies@q-cells.com I WER www.q-ceils.com Engineered in Germany OCELLS Enphase Microinverters Re,mon� AMI-RICAS Inn, nase and 11H0.1,11 7+ 111%0#41 1 c r ol n v e r t e r s To learn more about Enphase offerings, visit enphasecom The high-powered smart grid -ready Enphase IQ 7 MicroTm and Enp.,'­mse IQ 7+ Micro - dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy'm, Enphase IQ BatteryTM, and the Enphase EnlightenTM monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, enabling Enphase to provide an industry -leading warranty of up to 25 years. Lightweight and simple Faster installation with improved, lighter two -wire cabling Built-in rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable Optimized for high powered 60-cell/120 half -cell and 72- cell/144 half -cell* modules More than a million hours of testing Class 11 double -Insulated enclosure UL listed Smart Grid Ready Complies with advanced grid support, voltage and frequency ride -through requirements Remotely updates to respond to changing grid requirements Configurable for varying grid profiles Meets CA Rule 21 (UL 11741-SA) 'The IQ 7+ Micro is required to support 72-cel 1 /144 h a I f-cel I modules. ""N'ENPHASE Enphase IQ 7 and IQ 7+ Microinverters =NPUT DATA (DC) — IQ7-60-2-US IWPLUS-72-2-US Commonly used module pairings! 235 W - 350 W 235W-440Vet + Module compatibility 60-ce11"120 half -cell PV modules 60-cell/120 half -cell and 72- only cell/144 half -cell PV modules Maximum input DC voltage 48V 60 V Peak power tracking voltage 27 V 37 V 27 V- 45 V Operating range 16 V - 48 V 16 A - 60 V Min/Max start voltage 22V/48V 22 V / 60 A Max DC short circuit current (module Ise) 15 A 15A Overvoltage class DC port 11 11 DC port backfeed current 0 A 0 A PV array configuration I x I ungrounded array; No additional DO side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) IQ 7 Microinverter IQ 7+ Micirtainverter _�5ea­b'o_ut,_pu'_'t_p ow—ei-, . .... ................... 2`5" 6-f . . ..... ......... ..... ... . Maximum continuous output power 240 VA 290 VA Nominal (L-L) voltage/ronge2 240 V / 208V/ 240 V / 208 V 211-264 A 183-229 A 211-264 A 183-229 V Maximum continuous Output current 1.0 A (240 V) 1,15 A (208 V) 1.21 A (240 V) 1.39 A (208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47 - 68 Hz 47 - 68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A (L-L) branch circuit' 16 (240 VAC) 13 (208 VAC) 13 (240 VAC) 11 (208 VAC) Overvoltage class AC port III III AC port backfeed current 18 mA 18 mA Power factor setting 1.0 1.0 Power factor (adjustable) 0,85 leading ... 0.85 lagging 0.85 leading 0,85 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak efficiency 9716 a 9T6 % 97.97.3%� or CEC weighted efficiency 97.01 9TO % 9 7, 0 x, 97,0% MECHANICAL DATA . . . .... ....... .. . Ambient temperature range ... ......... - ­­­­_,_­­­­­ .. . ....... -401C to +651C Relative humidity range 4% to 100% (condensing) Connectortype MC4 (or Amphenol H4 UTX with additional Q-DCC-5 adapter) Dimensions, (HxWxD) 212 rum x 175 mm x 30.2 mm (without bracket) Weight 1.08 kg (2,38 lbs) Cooling Natural convection - No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class 11 double -insulated, corrosion resistant polymeric enclosure Environmental category UV exposure rating NEMA Type 6 outdoor FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DO connectors have been evaluated and approved by UL for use as the load -break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741 -SA) UL 62109-1, UI-1 741 /IEEE] 547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 1071-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22 1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DO conductors, when installed according manufacturer's instructions. No enforced DUAC ratio. See the compatibility calculator at h_Jfpa,,ZyQapk_a_ , ra _&e se—ca a 2. Nominal voltage range can be extended beyond nominal if required by the utflily. 3. Limits may vary. Referlo local requirements to define the number of microinverters per branch in your area To learn more about Enphase offerings, visit enphase.com `=�ENPHASE -ne, cy (c �!)e T ,D`ease ono T Tl�, lase nr)`ase 2020 and other (IT seiv�ce rmmes am- fl. trade, k_', of rcl,ase _iwigv m Data sAibjeci tochange 2020 08 12 4Less Aluminum 4more Efficient Design F' )/Addonal Mounting Options 4metal3 EPDK TPO, & Asphalt Roofs ICC ESR 3575 RT Serrated Hex Flange Bolt/Nut- 5116-18 x V" RIT-MINI 11 is suitable for all systems with a conve ntional L-Foot. 1WT x 1" Carriage Bolt EMT I \ Accessory N vv MI RT-Butyl (RT2-04-MNBUTYL): 10 ea./Box I RT-Buityl is Roof Tech's flexible flashing used in one million residential PV systerns for the last 27 years, 11, Is the first PV mounfing system with Flexible FlashOng certified by the ICC, Engineered to withstand wind speeds up to 180 mph and ground snow up to 90 psf, IWASM71=011 M6531A Tima-41 MANI . I i I . , k I TAS 100 A on, metal and asphalt roof, RE. Starnoed Letters available at www.roof-tech.us/sur)Port Dimensio-ns in (mm) C 3.54 inch (90mm) .60 inch (15.4mm) Offset Rafter Attachmene*�,�� L�� MMI 2�= FLORIDA BUILDING CODE COMPLIANCE 4EcoFcisten, For Installers. By Instalters. FLORIDA BUILDING CODE 2020 REQUIREMENTS Questions often arise in the solar industry as to the requirements for installing solar mounting systems in Dade and Broward counties and throughout the rest of the Florida, Outlined below are the four requirements to comply with the 2020 Florida Building Code. The first three requirements are necessary for solar racking systems, while the fourth is specific to solar roof attachments. The fifth item, Florida -specific testing, is optional for installation. I - U L CERTIFICATIONS ,'- Racking UL2703 (Supplied byEcoFast en) Wl- 3 - RACKING STRUCTURAL CAPACITY Florida PE stamped system capacity and span tables that meet site conditions and roof zones for the project (Supplied by EcoFast en) 4 - ROOF ATTACHMENTS Structural Capacity certification letters that meets or exceeds site conditions (Supplied by EcoFast en) ry Waterproofing/Flashing per NRCA & FRS RI (Florida) guidelines (Supplied by EcoFasten, when applicable) 5 - OPTIONAL FLORIDA SPECIFIC TESTING OR CERTIFICATIONS Florida Product Approval Miami Dade NOA Water Seal Testing: TAS100(A) (requiredfor HVHZ Florida Product Approval or Miami Dade NOA) For In'tatletr hostallers ECOFASTEN ROOF ATTACHMENTS — FLORIDA COMPLIANT EcoFasten offers two roof attachments that meet the specifications for installation in the State of Florida, which are GF-10 and Q8-1 as shown below. GF-11 is a versatile solution for use on composition shingle roofs. The 8" x 12" flashing installs with a single fastener and when combined with an EcoFasten compression bracket, a watertight seal is created, maintaining the integrity of the roof. Available CIF-10 SKUs: * 3012010 - GF-1 FLASHING GLV BLK 8x12" 0 3012011 - GF-1 FLASHING GLV ALL 8X12" Available Compression Brackets: * 2012022 - CF UNIV L-FOOT MLL 3" GF-111 Structural Capacity Documentation for Permit Packets GF-1 Installation Manual FIorida 08.11.20121 v2.0 EcoFasten, Por 3maatle1s, By >nstatters, ZEMSEMEM ECOWTEN ROOF ATTACHMENTS — FLORIDA COMPLIANT QB_1 Q13-1 uses a super strong base that can be used on composition shingle, tile, shake, slate, metal shingle, and low slope rooftops. This is a rail -based solution is ideal for new residential construction projects. The base can be installed prior to the roofing material, allowing for the roof to be shingled or tiled around the posts. Available QB-1 SKUs: 0 3017010 - QB-1 BASE AL 0 3017011 - QB-1 POST AL MLL 4.5" * 3017012 - QB-1 POST AL MLL 6.5" * 3017013 - QB-1 FLASHING AL MLL 12X12" * 3017014 - QB-1 FLASHING AL MLL 18X18" # 3017015 - QB-1 EPIC M COLLAR BLK 1.25" Q13-1 Structural Capacity Documentation for Permit Packets ,Ir 0 �&­�LSL,qte of Flqti Q� WicotLcLin 1, hLf�r 0L29,.2Q_,1,' �'�,EcoFasten, For Instatters, By Institters mzc�� ECOFASTES RACKING SYSTEM — FLORIDA COMPLIANT ClickHtO is one of the fastest installing rail -based systems in the industry. With its click -in rail assembly, the rails can be connected to any of EcoFasten"s composition shingle, tile, and metal roof mounts in seconds without the need for fasteners or tools. The ClickFft system is made of robust, anti -corrosive materials, such as aluminum and cold formed coated steel, to ensure the strength, corrosion resistance, and longevity, Available ClickFit Rail SKUs: * 2012021 - CF STD RAIL ALL AL 14FT 0 2012025 - CF STD RAIL AL MLL 171_5" ClickFit UL 2703 Certification for Permit Packets CfickFit UL 2703LI rq �ved #�,�tqilqtiotLlAt/l int-al Vej:,Lt2a QL v2.5 pR L (--IickFitUL2703,.42r)L,c)vedAddendtirr?06,0',7,20,21vl,1 ClickFit Master Letter CertylLcati 1X15,2021 L , CH&HtUL441 Rain Age�03.1�7022 EcoFasten. For Installers. By Installers. MEMO= GF-1 CUT SHEETS M &am ----- --------- --- -- ..... .. ... WATERPROOFING PER NRCA GUIDELINES Designed and Certified for Compliance with the Florida Building Code & ASCE/SEI-7 - - - ------- ---------- --------- ----- — - - ---------------------- . ......... EcaFasten, For instaklers By Instatters QB-2 CUT SHEETS AUK a SASE lic "IS rbm�v 3017015 QB-1 EPDM COLLAR OLK 1.25" D STRUCTURAL CERTIFICATION Designed and Certified for Compliance with the Florida Building Code & ASCE/SEI-7 EcoFasten. 'or hmtallers, By Instattem EcoFasten I Pagel QB-1 CUT SHEETS 3017012 QB-1 POST AL MLL CS" .. .......... .... ... STRUCTURAL CERTIFICATION Designed and Certified for Compliance with the Florida Building Code & ASCE/SEI-7 . .... ... .... - ----- - ---- ............ ,''-RoFasten, For ln,,taRers, By Instatters, MM= CUT" SHEETS i_ i6f. swU 4tiJ4, .fxt .. d . 3017 14 3-1 FLASHING AL MLL 18X1 " i --------- WATERPROOFING PER NRCA GUIDELINES Designed d Certified for Compliance with the Florida BuildingCode & ASCE/SEI-7 (or Inst tiers. By Instatterc CLICKFIT CUT SHEETS T-, -------- -------- - - --- ------ STRUCTURAL CERTIFICATION Designed and Certified for Compliance with the Florida Building Code /SEI-7 UL 2703 Conforms to UL 2703 Mechanical & Bonding requirements. See EcoFasten lick it Installation Manual for full ratings, EcoFasten For Instatters. By Instatters EcoFasten I Page 10 PERM17TING PACKETS Listed below is the documentation you will need to provide to your AHJ for permitting approval. Click on the link to download fife UL 2703 CERTIFICATIONS: £ , State, o Flor(da Cgrtificatfor kgtl 0722L20�1 y , hic Fit UL 441 Rahn Re rt 03,17,2021 INSTALLATION MANUALS: G :-1 t st ilt ti rr A4 nualrloriday.11 2 1 v .0 ,-,1 t t ti tt r� a L $ .27 2 L OPTIONAL CUT SETS: } 201202 - CFSTQ RAIL MLL AL 14FT Cut Sheet 2012,022 - CF UNI t,-F-V T &ILA. ".," Cut .sheet 2012025 r, ` STD RAIL AL, ILL 1 ' . " Cut Sheet 3011 - 'm t FLASHING t ML 8 "3 Cartsheet 010 At ,girt Shee, ` - l � Q TAL O t t, ,5" Cut Sheet 301r` -'t,-_ - POSTAL L a5*',"tit t 0 z t - h FLASHING At MLL IZX12" Cut Sheet 3017014-0 LA 01701 - Qg-1 EPOMR BLS 12€µCut Sheet For'mtalae,,,,. By mstatters, �- '•` \. .f .2. 1 'i � , t \\1 :l 1. , ,1 � .�1 1 ".� t s ..1 ..:. �. . \i `i - '•\' 1� �, >,,. ail... 1\ \ \. CONTACT ECOFASTEN 4141 W Van Buren Street, Suite 2, Phoenix, AZ 85009 877.859.3947 1 ecofastensolar.com EcoFasten, For § a ttka ". Fly` tr sta tR rs . EMMEMIEMM ZMERM EcoFasten Solar LLC Phoenix, AZ 85009 TEL: (877) 859-3947 Attn.: Ecol'asten Solar LLC - Engineering Department Re: Report # 2019-11325HGS.01 Engineering Certification for the Ecol'asten Solar LLC ClickF!t - Rail System for Gable and Hip Roof. PZSE, Inc. - Structural Engineers have reviewed EcoFasten Solar LLC ClickF!t System. All information, data, and analysis contained within the EcoFasten Solar LLC lick it System Rail span tables are based on and comply with the following codes: 1, Minimum Design Loads for Buildings and Other Structures, ASCE/SEI 7-16 2. 2018 International Building Code, by the International Code Council, Inc. 3. 2018 International Residential Code, by the International Code Council, Inc. 4� AC428, Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV) Panels, November 1, 2012, by ICC-ES 5, Aluminum Design Manual 2015, by The Aluminum Association, Inc. Following are typical specifications to meet the above code requirements: Design Criteria: Ground Snow Load = 0 - 60 (psfl Basic Wind Speed = 90 - 180 (mph) Roof Mean Height = 0 - 30 (ft) Enclosed and Partially Enclosed Gable and Hip Roof Pitch = 0 0 - 600 (degrees) Exposure Category = 8, C & D Attachment Devices: The evaluation of the ClickFit System considers the ClickFit L-Foot, Rail: The evaluation of the ClickFit System Rail p/n 2012021 (450124, REV X03), made with an aluminum alloy, 6000 series, with a minimum yield strength of 35 ksL Cantilever: Maximum cantilever length is L/3, where "L" is the span noted in the Span Tables, provided at least I module length between maximum cantilevers. 1478 Stone Pont Drive, Suite 190, Roseville, CA 9566' 916.961.3960 916,961,39 '', �&rvvw.pzse.corn, Tolerance(s): 1.0 tolerance for any specified dimension in this report is allowed for installation. PV Module Size: 60-Cell PV Panel max dimension 72-Cell A. Panel max dimension Is 80.4". Installation Orientation: Landscape (L) - PV Panel long dimension Is parallel to the ridge/eave line of the roof, and the PV panel is mounted on the short side. Portrait (P) - PV Panel short dimension is parallel to the ridge/eave line of the roof, and the PV panel Is mounted on the long side. Roof Zones — Enclosed and Partially Enclosed Gable Rooft, O:S 70: 11 Nm"" lete-MiTli "ItTim- .3-21 *-fASCF 7-16. JtLL,%ULe SEE DETAIL FOR MOUNT LOCATION EDGEZONE(D EDGE OF ROOF Figure 1: Roof Edge and Corner Zones, Gable Roofs, 0:5 710 1478 Stone Point C',dve, Suite 190, Roseville, CA 95661 916,961,3960 9 16,9 'A I 3 9 65 wv-""aPzmcon 1 ER ZONE E T41L DE J MOUNTILOCA'110N z RIDGE CORNER ZONE 031, z SEE DETAIL F 6 MOUNT LOCATION CABLE EDGE ZONE WrHEDAREA MCATES V DISTANCE MINIMUM OF 34r I M 3 i CORNER ZONE tEE DETAIL FOR . .... UOIJNT LOCATION WALL - EDEIE OF ROOF Figure 2: Roof Zones, Gable and Hip Roofs, 70 < Ells 450 Panel with Support Mounts In Multiple Roof Zones: ,211 the mounts supporting the module. Notes: 1) Tables are determined for Rail and L-foot only and does not include roof capacity check. 2) Risk Category 11 per AS CE 7-16. 3) Topographic factor, kzt is 1.0. 4) Average parapet height is 0.0 ft. 5) Wind speeds are LRFD values. 6) Attachment spacing(s) apply to a seismic design category E or less. Panel Array Edge: ��anels exposed at array edge shall use figure 29.4-7 of ASCE 7-16 to determine "dj" and "d2" to apply "Array Edge' spans that apply to an array layout. See figure 3. 1478 Stone Point Drive, Suite 190, Roseville, CA 9566 91 A,961.3960 91 k961.3,?6r, W-AAN, 0 , ZSe.COril ME ��WVEW NON EXPOSED ARRAY fr EXPOSED ARRAY EWE Mr — Bow OF SOLA EDGE OF ADJACENT SOLAR ARRAY OR BUILDING EDGE Figure 3: Array Edge Design Responsibility: These tables are intended to be used under the responsible charge of a registered design professional where required by the authority having jurisdiction. In all cases, these tables should be used under the direction of a design professional with sufficient structural engineering knowledge and experience to be able to: Evaluate whether these tables apply to the project, and Understand and determine the appropriate values for all input parameters of these tables. This letter certifies that the EcoFasten Solar LLC ClickFit Railed System, when installed according to the limitations of this letter and the attached span tables, complies with the above codes and loading criteria. This certification excludes evaluation of the building structure to support the loads imposed on the building by the array; including, but not limited to strength and deflection of structural framing members, fastening and/or strength of roofing materials, and/or the effects of snow accumulation on the roof. Structures will require additional knowledge of the building and are outside the scope of the certification of this racking system. If you have any questions on the above, do not hesitate to call. Prepared by: PZSE, Inc, —Structural Engineers Roseville 478 Stoine Point Drive, Suit e 190, Rosevillo, CA 95661 9 1 &961 _19760 916,961.396,5 v"'v^'1Pz$e'C0?71 Table of Contents It..................... ...... a .............................. .................. _ ... . .................. . .......................................... Page # Part 1: EcoFast en Flush -Mount lick it System with L-foot - Enclosed Hip and Gable ............................................................ Span Tables for Flush -Mount is Fit System on 0-30 Foot Roof, 60-Cell Modules - Portrait__ ..... ............. ..... . 6 Span Tables for Flush -Mount CickFit System on 0-30 Foot Roof with 72-Celt Modules - Portrait . .. ................. -14 Span Tables for Flush -Mount CickFit System on 0-30 Foot Roof with 60-Cell & 72-Cell Modules - landscape...... 22 Appendix A: Ecofasten lick It Cut Sheets........_ ..... ........... ..... __ .. .......... ..... ....... 30 1478 Stone Point Deve, Suffe 190, Roseville, CA 95f,,61 916.961,3960 91 &961,3965 N&-,APW.pzSe.Corn RM MEM mm HEM OW" ROM amm PAIME PERM Kam Company a Feb 19, 2021 Designer e 6;43 AM Job Number: Chocked ye Material T = General ha _ i trary R4mb r of 6p ® 1 Basicperti : %tal Width 1.576 In T vial Might 1.575 in ntrold, Xo 0.Q In 0.786 in -far (Right) ip 0,767 in _ t S n ti 0.77 Y r (Tr3p} 0.788 in Y r (hot) 0.786 in 1 M i hlk 1.75 in Equivalent Properties: , Area, Ax 0.373 InA2 Inertia, 1xx a 0161 Ind 4 C — tnrti, iyy 0100 _ Ind r Inertia, Ixy -0a000 to . . . x (Top). , 0.191 Ih�3 - I 01.1 1 1nA3 _ _ y (Lett) _ _ 0126 inA _ Section Diagram y (Right) 0.126 In"1 rx 0.65 In ry 0.516 — - in - Plastic Zx 0,222 InA i�taifilc ii 0.160 inA3 _ Torsional J <No Calc.> As-xx Oaf 1.000 As-yy Oaf 1.00 As-xx ass 1.000 A yy Stress 1.000 C:\RISA\SecUonPmjecti page t t Kai E " ' V t�!T-NN PRS MOMEEIM] EcoFasten Solar LLC 4141 W Van Buren St, Ste 2 Phoenix, AZ 85009 TEL: (877) 859-3947 Attn.: Eco Fasten Solar - Engineering Department Re: Report # 2019-12325HG.05.01 — EcoFasten - ClickFlt System for Gable and Hip Roofs Subject: Engineering Certification for the State of Florida PZSE, Inc. — Structural Engineers has provided engineering and span tables for the EcoFasten - ClickFit System, as presented in PZSE Report # 2019-11325HG.05.01, "Engineering Certification for the EcoFasten - ClickF!t System for Gable and Hip Roofs". All information, data, and analysis therein are based on, and comply with, the following building codes and typical specifications: Building Codes: 1. 2020 Florida Building Code, by Florida Building Commission 2. ASCE/SEI 7-16, Minimum Design Loads for Buildings and Other Structures, by American Society of Civil Engineers 3. 2018 International Building Code, by international Code Council, Inc. 4. 2018 International Residential Code, by International Code Council, Inc. 5. AC428, Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV) Panels, November 1, 2012 by ICC-ES 6. Aluminum Design Manual 2015, by The Aluminum Association, Inc. 7. ANSI/ AWC NDS-2018, National Design Specification for Wood Construction, by the American Wood Council Design Criteria: Risk Category 11 Seismic Design Category = A - E Exposure Category = B, C & D DIGITALLY SIGNED Basic Wind Speed (ultimate) per ASCE 7-16 = 90 mph to 180 mph N! %%%11111111110, Ground Snow Load = 0 to 60 (psf) ZA6�&e A�kno 73522 This letter certifies that the loading criteria and design basis for the o, EcoFasten - CllckFit System Span Tables are in compliance with the above codes, If you have any questions on the above % jt� ....... ....... . 7HIS 17190 HAS BEEN ELECTRONICALLY S11,GNED NNID SIEEAILE N' , PAUPAU, ,, K, ,7,,A.C,,+`_`­R. USNG A SHA-1 AU"'��,-HENTICA,i,,",',)N c"ODC,"', Prepared by: PZSE, Inc. —Structural Engineers PRNIFTED COPIES 01P"THIS D0,`,UMENARE N01CON, OERED Slc'�,NED Roseville, CA ANID SE,,`,A11_ED AND THE SHA­1 ALVFIFEWICATION CODF MUST`,E fit: ,-R1F1,,E,`,-,D I')N ANY ELE,(.,,11-R0N1C 1478 Stone Point Ddve, Suite 190, Roseville, CA 95661 916,961,3960 916,9613965 kv\Anvv.pzse.com W9 [20D] DETAIL ALE 1 : ll m PER MODULF t INSTALLATION MANUA, SECTION -A 1.57 [44.&] FRONT VFW l-FOOT 1.50 [b) 176 [ .11 SIDE VIEW 1-FOOT i.57 . [D] FRONT VIEW i AR, n p h a s e 1 IJ ^01 "31 ko "Tlitsiln, (X-lQ-AM1-240-3) LISTED To learn more about Enphase offerings, visit enphasecom The Enphtase 10 Cornbinew,iris with Enphase IQ Envoy" consolidates interconnection equiprnent into a single enclosure and streamlines PV and storage installations by providing a consistent, pre -wired solution for residential applications. It offers Lip to four 2-pole input circuits and Eaton BR series busbar assembly, Includes Q Envoy for communication arolccrrrtro� Flexible networking supports Wr-R, Ethernet, or cellular Optional AC receptacle available for PLC budge Provides production metering and optional consumption moniloring Reduced size from previous combiner Centered mounting brackets support single stud mounting Supports back and side conduit entry kip to four 2-pole branch circuits for 240 VAC plug-in breakers (riot included) 80 A total PV or storage branch circuits Durable NIRTL-cerfified NEMA type 3R enclosure Five-year warrants UL listed - ... rti..,,,r ENPHASE, Enphase IQ Combiner 3 MODEL NUMBER IQ Combiner 3 X-IQ-AM1-240-3 IQ Combiner 3 with Enphase IQ Envoy" printed circuit board for Integrated revenue grade PV production metering (ANSI C12,20 +/- 0.5%) and optional* consumption monitoring (+/- Z5%), ACCESSORIES and REPLACEMENT PARTS (not Included, order separately) Enphese Mobile Connect' CELLMODEM-03 (4G / 12-year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60 CELLMODEM-01 (313 / 5-year data plan) microinverters, (Available In the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, CELLMODEM-Ml (4G based LTE-M / 5-year data playa) where there Is adequate cellular service In the installation area Consumption Monitoring* CT CT-200-SPLIT Split core current transformers enable whole home consumption metering (+/- Z5%)e Circuit Breakers Supports Eaton 811210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers, 5RK-10A-2-240 Circuit breakeL 2 pole, 1 OA, Eaton BR210 BRK-15A-2-240 Circuit breaker, 2 pole, 1 SA, Eaton BR215 BRK-20A-2P-240 Circuit breaker, 2 pole, 20A, Eaton BR220 EPLC-01 Power line carrier (communication bridge pair), quantity 2 XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in 10 Combiner 3 (required for EPLC-01) XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board (PCB) for Combiner 3 ELECTRICAL SPECIFICATIONS Rattng System voltage Eaton Bit series busbar rating Max. continuous current rating (output to grid) Max, fuse/circuit rating (output) Branch circuits (solar and/or storage) Max, continuous current rating (input from PV) Max, total branch circuit breaker rating (input) Continuous duty 1201240 VAC, 60 Fiz 125 A 65A 90 A Up to four 2-pole Eaton BR series Distributed Generation (DO) breakers only (not Included) 64 A BOA of distributed generation I 90A with 10 Envoy breaker included Production Metering CT 200 A solid core pre -installed and wired to IQ Envoy MECHANICAL DATA Dimensions (WxHxD) 49.5 x 37.5 x 16,8 cm (19.5'x 14,75'x 6,63')- Height is 21.06'(53.5 cm with mounting brackets). Weight 7.5 kg (16.5 lits) Ambient temperature range -401- C to +46" C (400 to 11511 F) Cooling Natural convection, plus heat shield Enclosure environmental rating Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction Wire sizes 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors 60 A breaker branch input: 4 to 1/0 AWG copper conductors Main Itai combined output: 10 to 210 AWG copper conductors Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. Altitude To 2000 meters (6,560 feet) INTERNET CONNECTION OPTIONS integrated WI-Fi 802,11b/g/n Ethernet Optional, 802,3, CatSE (or Cat 6) UTP Ethernet cable (not included) Cellular Optional, CELLMODEM-01 (3G) or CELLMODEM-03 (4q) or GELLMODEM-Ml (4G based LTE-ag (not included) COMPLIANCE Compliance, Combiner UL 1741 CAN/CSA C22,2 No, 1071 47 CFR, Part 15, Class B, ICES 003 Production metering: ANSI C12,20 accuracy class 0,5 (PV production) Compliance, 10 Envoy UL 60601-1/CANCSA 22,2 No. 61010-1 * Consumption monitoring is required for Enphase Storage Systems. To learn more about Enphase offerings, visit eniphase.com 0`�` CP 2018 Enphase Energy. All -,'ghts reserved, All trademarks or brands in this document are registered by their respective owner, 2018-09-13 Rooftop Solar Junction Box Flashing Unit Manufactured by: Soltection: a division of Vynckier Enclosure Systems, Inc, 271 McCarty Street Houston, TX 77029 I 1-866-227-05,V7 www.soltection.com Soltection RJ-1 Installation Manual Pa93U www.soltection.com Soltection RJ-1 Installation Manual Page 2 TABLE OF CONTENTS INSTALLATION INSTRUCTIONS m9amm IMPORTANT SAFETY INSTRUCTIONS............. ... --- ...... ...... 4 SAFETY WARNINGS A CAUTIONS ... ....... ...... ........ ...... 4 ELECTRICAL PRECAUTIONS ...... ...... 5 MECHANICAL PRECAUTIONS ....... ...... .......... 5 PRODUCT INFORMATION ...... ....... ........ - ...... ...... 6 6 PREP & PLACEMENT ... ......... ........ ...... — ...... ...... 7 REQUIRED T00LS.------- .... ............. ....... ...... 7 PRODUCT PLACEMENT... ........... 7 SPECIFICATIONS ......... MECHANICALJ ELECTRICAL ......... ......... — ........ ....... --- ....... TORQUE RATINGS. .... ...... ....... WARRANTIES. Seller warrants to Buyer that products and any services furnished hereunder will be free from defects in material, workmanship and title and will be of the kind and quality specified in Seller's written quotation. The foregoing shall apply only to failures to meet said warranties (excluding any defects in title) which appear within two years from the date of shipment hereunder. The conditions of any tests shall be mutually agreed upon and Seller shall be notified of, and may be represented at, all tests that may be made, The warranties and remedies set forth herein are conditioned upon (a) proper storage, installation, use and maintenance, and conformance with any applicable recommendations of Seller and (b) Buyer promptly notifying Seller of any defects and, if required, promptly making the product available for correction. If any product of service fails to meet the foregoing warranties (except title), Seller shall thereupon correct any such failure either at its option, (i) by repairing any defective or damaged part or parts of the products, or (11) by making available, F.O.B. Seller's plant or other point of shipment, any necessary repaired or replacement parts. Where a failure cannot be corrected by Seller's reasonable efforts, the parties will negotiate an equitable a0lustment in price. The preceding paragraph sets forth the exclusive remedies for claims (except as to title) based on defect in or failure of products or services; whether the claim is in contract, indemnity, warranty, tort (including Seller's negligence), strict liability or otherwise and however instituted. Upon the expiration of the warranty period, all such liability shall terminate and Buyer shall have a reasonable time, within thirty days after the warranty period, to give written notice of any defects which appeared during the warranty period, Except as set forth in Article 2, "Patents," the foregoing warranties are exclusive and in lieu of all other warranties, whether written, oral, implied or statutory. NO IMPLIED STATUTORY WARRANTY OF MERCHANTABILITY OR FiTNESS FOR PARTICULAR PURPOSE SHALL APPLY. Seller does not warrant any products or services of others which Buyer has designated, www,soltection.com Soltection RJ-1 Installation Manual Page 3 a NOTE: SAVE THESE INSTRUCTIONS This manual contains Important Instructions that shall be followed during Installation and maintenance of the Soltection RJA rooftop junction box with fleshing, LETHAL VOLTAGES ARE PRESENT DURING THE INSTALLATION, OPERATION AND SERVICE OF THIS EOUIPMENT, PROPER PRECAUTIONS MUST BE TAKEN AT ALL TIMES TO ENSURE THE SAFETY OF THE SERVICE PERSONNEL. • Only qualified personnel or licensed electricians should Install this product and the instructions herein are provided for those individual(s) only. • To reduce the risk of electric shock, injury, or death, all electrical wiring and connections must be performed by qualified personnel. • Lethal voltages are present during the installation, operation, and servicing of this equipment. Proper precautions must be taken at all times to ensure the safety of the service personnel. ® Follow state and federal Occupational Safety and Health Administration (OSHA) guidelines and regulations when installing this product. Utilize proper Personal Protective Equipment (PPE) as required per national and local regulations as well as for installation best practices. Install this apparatus in accordance with ANSI/NFPA 70, National Electrical Code (NEC). Follow all national or local electrical codes. Install, operate, and use this product in a manner consistent with the instructions provided. Failure to follow the procedures Indicated may result In roof leaks, property damage, or consequential damage. www.softection.com Soltection RJ-1 Installation Manual Page 4 * Ensure all electrical conductors are at zero voltage potential before installing or servicing this unit. * Never break contact on a circuit without using the appropriate disconnect device. * Follow established lockout and tagout procedures for all electrical conductors prior to servicing. * Beware of power lines in the vicinity of the roof, where inadvertent contact may result In electrocution, personal injury, or death. * When disconnecting source or supply circuits, provide sufficient time as stated in the power electronics manufacturees instruction manual In order to ensure discharge of all conductors in the circuit. * Always verify the Integrity and proper installation of the electrical components prior to energizing electrical circuits. Non-metallic enclosures do not provide grounding means between conduit connections. The use of grounding hubs and jumper wires are required. 0 Grounding must be sized per NEC requirements, and is the responsibility of the installer. MECHANICAL PRECAUTIONS When drilling into an attic space, ensure that electrical wires, mechanical obstructions, or potential electrical hazards are removed from the vicinity and direction of the drill. Do not install if the roof Is wet, frosted, or covered by ice or snow, If any part of this product becomes damaged, remove and destroy the entirety of the unit. Failure to do so may result in fire, property damage, personal injury, electrocution, or death. Do not use the product to anchor fall protection equipment. www,soltection.com Soltection RJ-1 Installation Manual Page 5 PRODUCT INFORMATION * The Soltection RJ-1 Residential Rooftop Junction Box is a flashed roof penetration designed to protect electrical conductors entering the rooftop/attic. It is made of a high -strength W-resistant and UV - stabilized polymeric material. * The Rol-1 enclosures comes fully equipped with a slatted DIN rail mounted inside the enclosure designed for mounting of DIN rail accessories, such as terminal blocks, A four position ground bar is also provided as a means to form a bond between the solar array mounted on the roof and the building. AFFIXING DIN RAIL MOLDED BASE "CORNERSCREWS PLASTIC SCREW FOR GROUND BAR Iffinumal= www,soltection.com Soltection RJA Installation Manual Page 6 1 Identify the location and placement of the fleshing the roof as shown. The product may be mounted beneath the array or adjacent to the array. O NOT LOCATE THE PRODUCT D E T Y OVER RAFTER T ENSURE THE RAFTER DOES NOT INTERFERE WITH THE WIRING ENTRY INTO THE A171C www.soltection.com Soltection IU-1 Installation Manual Paga is i, Manual Page 9, www.soltection.com Soltection R)-1 Installation Manual Pageo www.soltection.com Soltection RJ-1 Installation Manual Page 10 a • Product Certifications: UL508 • Enclosure Rating: Type 4X • Attic Conduit Pass Through Connector Size Range: 1/2" — I" • Max. Side Wall Conduit Size: I" Maximum Current: WA Maximum Voltage: NIA Ambient Operating Temperature: -35C to 75C Table TI: Ground Bar Connection, Wire Range: #4 to #14, 4 Usable Connections Wire- S" "1z", i- L fitening Torque (lb. In 35 8 AWG Table T3: 191que Yalues, Cover/Lid Screws , 4 Provided, Captive JW4tenlnqlllor!;I!��« www.soltection.com Soltection RJ-1 Installation Manual Page JH vVnckier 271 McCarty Street Houston, TX 77029 I 1,866-227-0577 w E, " n pill, s e do-1 11 C��`,On, M lb (MID-AM1-240-3) LISTED To learn more about Enphase offerings, visit enphasecom 'The Enpliliase IQ Combiner 3' with Enphase IQ Envoy" consolidates interconnection equipment into a single enclosure and streamlines PV and storage installations by providing a consistent, pre -wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. Smarl includes IQ Envoy for communication and control Flexible networking supports sh-Pi, Ethernet, or cellular Optional AC receptacle available for PLC bridge Provides production metering and optional consumption monitoring Reduced size from previous combine, Centered mounting brackets support single stud mountrng Supports back and side conduit entry Up to four 2-pole branch circuits for 240 VAC plug-in breakers (not included) 80 A total PV or storage branch circuits Durable NIRTIL-certified NEMA type 3R enciocurc Five-year warranty UL listed .. . .... . ENPHASE, Enphase IQ Combiner 3 MODEL NUMBER IQ Combiner 3 X-IQ-AM1-240-3 IQ Combiner 3 with Enphase IQ Envoy" printed circuit board for integrated revenue grade Ply production metering (ANSI C12,20 +/- 0,5%) and optional* consumption monitoring (+/- 2.5%). ACCESSORIES and REPLACEMENT PARTS (not Included, order separately) Enphese Mobile Connect' CELLMODEM-03 (4G / 12-year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60 CELLMODEM-fit (3G / 5-year data plan) rrucrorriverters, (Available In the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, CELLMODEM-Ml (4G based LTE-M / 5-year data plan) where there Is adequate cellular service In the installation area,) Consumption Monitoring* CT CT-200-SPLIT Split core current transformers enable whole home consumption mettiring (+/- Zs%). Circuit Breakers Supports Eaton BR210, BR215, BR220, BR230, BR240, OR250, and BR260 circuit breakers, BRK-I0A-2-240 Circuit breaker, 2 pole, 1 OA, Eaton BR21 0 BRK-15A-2-240 Circuit breaker, 2 pole, 1 5A, Eaton BR21 5 BRK-20A-2P-240 Circuit breaker, 2 pole, 20A, Eaton BR220 EPLC-01 Power line carrier (communication bridge pair), quantity 2 XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Cornbiner3 (required for EPLC-01) XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board (PCB) for Combiner 3 ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 120/240 VAC, 60 Hz Eaton BR series busbar rating 125 A Max, continuous current rating (output to grid) 65A Max, fuse/circuit rating (owput) 90 A Branch circuits (solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included) Max, continuous current rating (input from PV) 64 A Max, total branch circuit breaker rating (input) BOA of distributed generation / 90A with 10 Envoy breaker included Production Metering CT 200 A solid core pre-instalted and wired to IQ Envoy MECHANICAL DATA Dimensions (WxHxD) 49.5 x 37.5 x 16.8 cm (19.5'x 14,75'x 6.63'), Height is 21.06'(53.5 arn with mounting brackets), Weight T5 k9 f16.5 lbs) Ambient temperature range -400 C to +4611 C (-40" to 115° F) Cooling Natural convection, plus heat shield Enclosure environmental rating Outdoor, NIRTL-certified, NEMA type 311, polycarbonate construction Wire sizes 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors 60 A breaker branch input: 4to 1/0 AWG copper conductors Main lug combined output: 10to 2/0 AWG copper conductors Neutral and ground: 14to 1/0 copper conductors Always follow local code requirements for conductor sizing, Altitude To 2000 meters (6,560 feet) INTERNET CONNECTION OPTIONS Integrated Wi-Fi 80211b/g/n Ethernet Optional, 8023, Cat5E (or Cat 6) UTP Ethernet cable (not included) Cellular Optional, CELLMODEM-01 CIG) or CELLMODEM-03 (4q) or CELLMODEM-MI (4G based LTE-M) (not Included) COMPLIANCE Compliance, ComWner UL 1741 CANICSA C22.2 No, 1071 47 CFR, Part 1 5, Class B, ICES 003 Production rneterrng: ANSI C12,20 accuracy class 0,5 (PV production) Compliance, IQ Envoy UL 60601--I/CANCSA 22,2 No, 61010-1 * Consumption monitoring is required for Enphase Storage Systems. To learn more about Enphase offerings, visit eniphase.com Od 2018 Enphase Lneris. All,-ights reserved, All trademarks or brands in this document are registered by their respective owner. ENPHASE. 2018-09-13 11111111111� N A IN Rooftop Solar Junction Box Flashing Unit Manufactured by: Soltection: a division of Vync.kier, Enclosure Systems, inc, 271 McCarty Street Houston, TX 77029 1-866-227-0577 www.soltection.com Soltection RJ-1 installation Manual Pa 7M www.soltection,com Soltection RJ-1 Installation Manual Page 2 TABLE OF CONTENTS INSTALLATION INSTRUCTIONS NMM= IMPORTANT SAFETY INSTRUCTIONS .... ...... ...... --- ... . 4 SAFETY WARNINGS & CAUTIONS ...... ....... ......... --- 4 ELECTRICAL PRECAUTIONS ....... 5 MECHANICAL PRECAUTIONS ...... ....... 5 PRODUCT INFORMATION ....................................... 6 OVERVIEW---, 6 PREP & PLACEMENT ........ ...... 7 REQUIRED TOOLS...... ... ...... ........ 7 PRODUCT PLACEMENT., ....... ....... 7 SPECIFICATIONS ...... . ..... MECHANICAU ELECTRICAL— ... ...... TORQUE RATINGS... ........ ....... WARRANTIES: Seller warrants to Buyer that products and any services furnished hereunder will be free from defects in material, workmanship and title and will be of the kind and quality specified in Seller's written quotation. The foregoing shall apply only to failures to meet said warranties (excluding any defects in title) which appear within two years from the date of shipment hereunder. The conditions of any tests shall be mutually agreed upon and Seller shall be notified of, and may be represented at, all tests that may be made, The warranties and remedies set forth herein are conditioned upon (a) proper storage, installation, use and maintenance, and conformance with any applicable recommendations of Seller and (b) Buyer promptly notifying Seller of any defects and, if required, promptly making the product available for correction. If any product of service fails to meet the foregoing warranties (except title), Seller shall thereupon correct any such failure either at its option, (i) by repairing any defective or damaged part or parts of the products, or (ii) by making available, RO.B. Seller's plant or other point of shipment, any necessary repaired or replacement parts, Where a failure cannot be corrected by Seller's reasonable efforts, the parties will negotiate an equitable adjustment in price, The preceding paragraph sets forth the exclusive remedies for claims (except as to title) based on defect in or failure of products or services; whether the claim is in contract, indemnity, warran4l, tort (including Seller's negligence), strict liabill4i or otherwise and however instituted. Upon the expiration of the warranty period, all such liability shall terminate and Buyer shall have a reasonable time, within thirty days after the warranty period, to give written notice of any defects which appeared during the warranty period, Except as set forth in Article 2, "Patents," the foregoing warranties are exclusive and in lieu of all other warranties, whether written, oral, implied or statutory. NO IMPLIED STATUTORY WARRANTY OF MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE SHALL APPLY. Seller does not warrant any products or services of others which Buyer has designated. www,soltection.com Soltection RJ-1 Installation Manual Page 3 NOTE- SAVE THESE INSTRUCTIONS a This manual contains Important instructions that shall be followed during installation and maintenance of Soltection RJA rooftop junction box with flashing. I I'M * Only qualified personnel or licensed electricians should install this product and the instructions herein are provided for those individual(s) only. * To reduce the risk of electric shock, injury, or death, all electrical wiring and connections must be performed by qualified personnel. * Lethal voltages are present during the installation, operation, and servicing of this equipment. Proper precautions must be taken at all times to ensure the safety of the service personnel. * Follow state and federal Occupational Safety and Health Administration (OSHA) guidelines and regulations when installing this product. Utilize proper Personal Protective Equipment (PPE) as required per national and local regulations as well as for Installation best practices. Install this apparatus in accordance with ANSI/NFPA 70, National Electrical Code (NEC). Follow all national or local electrical codes. Install, operate, and use this product in a manner consistent with the instructions prov►ded. Failure to Wow the procedures Indicated may result In roof leaks, property damage, or consequential damage. www.soltection.com Soltection RJ-1 Installation Manual Pape 4 g * Ensure all electrical conductors are at zero voltage potential before installing or servicing this unit. * Never break contact on a circuit without using the appropriate disconnect device. * Follow established lockout and tagout procedures for all electrical conductors prior to servicing. * Beware of power lines in the vicinity of the roof, where inadvertent contact may result in electrocution, personal injury, or death. * When disconnecting source or supply circuits, provide sufficient time as stated in the power electronics manufacturer's Instruction manual in order to ensure discharge of all conductors in the circuit. * Always verify the integrity and proper installation of the electrical components prior to energizing electrical circuits. Non-metallic enclosures do not provide grounding means between conduit connections. The use of grounding hubs and jumper wires are required. 0 Grounding must be sized per NEC requirements, and Is the responsibility of the installer. When drilling into an attic space, ensure that electrical wires, mechanical obstructions, or potential electrical hazards are removed from the vicinity and direction of the drill. Do not install if the roof is wet, frosted, or covered by ice or snow. If any part of this product becomes damaged, remove and destroy the entirety of the unit. Failure to do so may result in fire, property damage, personal injury, electrocution, or death. Do not use the product to anchor fall protection equipment. www.soltection.com Soltection RJ-1 Installation Manual Pa'2Z I PRODUCT INFORMATION OVERVIEW The Soltection RJ-1 Residential Rooftop Junction Box is a flashed roof penetration designed to protect electrical conductors entering the rooftop/attic. It is made of a high -strength W-resistant and UV - stabilized polymeric material. The RJA enclosures comes fully equipped with a slatted DIN rail mounted inside the enclosure designed for mounting of IN rail accessories, such as terminal blocks, A four position ground bar is also provided as a means to form a bond between the solar array mounted on the roof and the building. AFFIXING DIN RAR ZMEM01HIMM -CORNER SCREWS :VY rtaK Q�K%_IVNU D/AK 0= www,soltectionxorn Soltection RJ-1 Installation Manual Page 6 ow PRODUCT PLACEMENT Identify the location rid placement of the flashing on the roof as shown, The product may be mounted beneath the array or adjacent to the array, ,`ADO NOT LOCA71 E THE ENSUREPRODUCT DIRECTLY OVER A RAFTER TO THE RAFTER DOES NOT INTERFERE WITH THE WIRING ENTRY INTO HE AT, C 4 www.soltection.com Softection RJ-1 Installation Manual PageG www.soltection.com Soltection RK Installation Manual PageU www.soltection.com Soltection RJA Installation Manual Page 10 2 * Product Certifications: ULS08A * Enclosure Rating: Type 4X * Attic Conduit Pass Through Connector Size Range: 112" — I" Max. Side Wall Conduit Size: I" Maximum Current: NIA Maximum Voltage: NIA Ambient Operating Temperature: -35C to 75C M""I" Mm' Table TI: Ground Bar Connection, Wire Range: #4 to #16 4 Usable Connections re Size Tightening Torque (lb - In) 4.6 AWG 35 Table T3. Torque Values, Cover/Lid Screws , 4 Provided, Captive TI �hte�blnferue �Ib-ln F--T, www.soltection.com Soltection RJ-1 Installation Manual Page 11 §', vVnckier Soltection is a division of Vynckier Enclosure Systems, Inc, 271 McCarty Street Houston, TX 77029 1 -866--227-0577 MODULE HANWHA SYSTEM INFORMATION INVERTER : ROOFTECH RT-MINI 11 W/ ECOFASTEN CLICK ::!c FIT RAIL RACKING SYSTEM YSTEM SIZE (DC) 28.2247216,-82.1751660 ROOF SHALL HAVE NO MORE THAN TWO LAYERS OF COVERING IN ADDITION TO Tj SOLAR EQUIPMENT ANY PLUMBING VENTS ARE NOT TO BE CUT OR COVERED FOR SOLAR EQUIPMENT INSTALLATION. ANY RELOCATION OR MODIFICATION OF THE VENT REQUIRES A PLUMBING PERMIT AND INSPECTION. * IIIIIN�l I * * s CRITERIAREQUIREMENTS FOR THE DESIGN * SPEED (PIS) 10 TOPOGRAPHIC EFFECTS SPECIAL WIND REGION MIND BORNE DEBRIS ZONE B NO 2 SEISMIC DESIGN CATEGORY C CLIMATE ZONE 2A MIND EXPOSURE CA` STORY E3 FBC, RESIDENTIAL 2020 TABLE 301,2.1.3 WIND SPEED CONVERSIONSa vUlt 110 115 120 130 140 150 160 170 180 190 200 V,,d 85 89 93 101 108 116 124 132 139 147 155 For SI9 1 mile per tour - 0.447 m/s. a. Linear interpolation is permitted. 11' 11 PV-1 COVER PAGE PV-1.1 ATTACHMENT RETAIL PV-2 PV-3 ROOF LAYOUT ELECTRICAL PV-11 PV-3.2 ELECTRICAL CONT, EQUIPMENT LABELS BILL OF MATERIALS MODULES 26 INVERTERS L-FOOT ATTACHMENT W/ RT-MINI 26 44 168" RAILS 11 ------------- SKIRTS 9 ENPFIASE COMBINER BOX EATON 60A FUSIBLE AC DISCONNECT 35A FUSES 1 --------------- 1 2 125A LINE TAPS 2 momentum SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 (732) 902-6224 MOMENTUMSOLAR.COM CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: C11057036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 * INITIAL I DATE: 1/11/2022 DESIGNER: NB ------------- REV: HATE: .DESIGNER:.._..A.... REV: DATE: DESIGNER: COVER PAGE W PER MODULE INSTALLAPON MANUAL SECTION A -A 0,79 1-57 1 1 1,50 [20-0] [40-0] A— [3810] 2,76 [70.1] DETAIL C DETAIL D FRONT VIEW SIDE VIEW SCALE 1 :6 SCALE 1: 6 L-FOOT LTOOT ----- --- ----- X0 NOT SCALE DRAWING NbOMETAXY AM CONIMBUVksWGN 7t' M �M 11 271 t 1,57 [40.0] L1 KFIT COMP SHINGLE Xx-XXXX-XXX RT-MINI is suitable for mounting any rail system with a conventional L-Foot. Dual bolt design, M8 or 5/16" for L-Foot & 1/4" fior EMC 1CC JCC ESR 3575 Call Now for more details 858-935-6064 Easy tapaxxt 1W H" Bog screw guide upper chaiuvI F111 1P .i_ Engineerpad W, ASTM D 1761 k, F-M-- --i—d" Components RT2-00-MINISK PAT "UING .iN Op' "I item 5 x Son" Mnunft 5ClSW (RT2-04Si/5�60)' 100 -18� R!T!7!t ,!yi(n - an=- ---- ---- — ----- RT-SWA bs Roof Tf;h's fWflash,,�nqued in 700,000 PV'.Ystems yx ,,as. 24,yews N is the fir PV rnounling SYFA'm M' Flexibie Flzishing �-,,Iffied by vhw Meal 11.5finig Retrofit Flexible Flashing Shedding water? 1W-Y,, Waterproof ICC ESR-3575 ASTM21 t-ft (7--W hrs.) in k1411 I-fing QUV Dimensions in (mm) Z� Fo 1 2 (50) 1 Rafter installation Deck installation RE, St—ped Lede. -igbiet --f-t-h-1suigsod momentum SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 (732) 902-6224 MOMENTUMSOLAR.COM CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 KAJOR BLVD. SUITE 307, ORLANDO FL. 32819 ZEPHYRHILLS ' FL 33542 2402465428 BLK-G8+ 340 INITIAL I DATE: 1/11/2022 1 DESIGNER: NB REV: DATE: DESIGNER: I . REV: DATE: --fDESIGNIGNER: PV MODULE RATINGS INVERTER RATINGS VOLTAGE DROP CALCULATIONS MODULE MAKE HANWHA INVERTER MAKE ENPHASE FORMULA USED PER NEC HANDBOOK 215,2(A)(4) WHERE APPLICABLE R momentum Q.PEAK DUO WIRE RUN Vnp I'P L (FT) VD % V, WIRE SIZE MODEL MODEL IQ7-60-2-US — SOLA BLK-G8+ 340 R BRANCH TO .I -BOX 240.00 13 1.98 EEE85.588 4.406 1.84% 12 AWG MAX POWER — 34OW MAX OUTPUT POWER 240W PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR J-BOX TO LOAD 50.0 325 HIGH STREET, METUCHEN, N3 08840 OPEN CIRCUIT VOLTAGE 403V OPEN DC VOLTAGE 48V 240.00 26 1.24 50.00 3.224 1.34% 10 AWG (732) 902-6224 MPP VOLTAGE 34.34V NOMINAL AC VOLTAGE — 240V CENTER _EEE MOMENTUMSOLAR.COM — LOAD CENTER TO AC 240�00 32.5 0378 3.00 OA52 0,06% 08 AWG PROFESSIONAL SHORT CIRCUIT CURRENT 10.4A MAX AC CURRENT 1A DISCONNECT ENGINEERING MPP CURRENT 9.9A — AC DISCONNECT TO CEC INVERTER EFFICIENCY 97% INTERCONNECTION 240.00 32.5 0A91 10,00 0.319 0,13% 06 AWG NUMBER OF MODULES 26 NUMBER OF INVERTERS 26 UL1703 COMPLIANT YES — 1703 COMPLIANT YES A/ PV BRE**E� SUB PANEL # OF MODULES PER BNCH THIS SOLAR PHOTOVOLTAIC SYSTEM COMPLIES WITH THE 2020 RA BREAKER SIZE FLORIDA BUILDING CODE AND THE 2017 NATIONAL ELECTRICAL CODE UP TO 16 20A %�%c FSEC CERTIFICATION STATEMENT: 26 HANWHA Q.PEAK DUO BLK-G8+ 340 340W MODULES PAIRED WITH PER FL. STATUE 377,705 , I, MINA A. MAKAR RE# 86753, CERTIFICATE OF AUTHORIZATION #33404, AN ENGINEER 26 ENPHASE IQ7-60-2-US MICRO -INVERTERS LICENSED PURSUANT TO CHAPTER 471,CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED 0 IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING _(rATt OF BRANCH CIRCUIT A CODE, FBC 2020 EXISTING GENERAL -INVERTERS NAL 13 MICRO ELECTRIC 200A MAIN BRANCH CIRCUIT B 13 MICRO -INVERTERS SERVICE PANEL 240 V MAIN BREAKER: 200A INE SIDE + ENPHASE80A HOT TAP + + AC COMBINER SOLAR CIRCUIT BOX DISCONNECTING MEANS EATON 60A FUSIBLE AC 200A GRID DISCONNECT 0 0 LA SOLAR CONTRACTUR CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 8 M --------- - ----------- ----- ..... .. .. ...... MOMENTUM SOLAR 0 ME A,- '_7 T I 'i U M M 1 5728 MAJOR BLVD. SUITE 307, ORLANDO,FL 32819 - - - --------- ---------- CUSTOMER INFORMATION ROOF F 1 OA/1 5A BREAKER 7POWER TILITY RICARDO HERNANDEZ AROCHO - MS92413 JUNCTION I JUNCTION (MANUFACTURER 38752 FEATHERING WAY 35A FUSES GROUND METER BOX SUPPLIED FOR ZEPHYRHILLS, FL 33542 TERMINATION CAP 1 2A-B ENVOY) 3 4 2402465428 INSTALLED ON 20A BREAKER (A) IPV SYSTEM '.INFOR—MATION END OF CABLE 20A BREAKER (B) -SYSTEM SIZE (DC): 8.84 KW 26 MODULES: HANWHA Q.PEAK DUO BLK-G8+ 340 26 INVERTERS: ENPHASE IQ7-60-2-US Wire Tag Conduit Wire City Wire Wire Type Temp. Wire Temp. Conduit Derated Inverter NOC (A) NEC Design Ground Ground Wire Gauge Rating Ampacity (A) Derate Fill Derate Ampacity (A) Qty Correction Current (A) Size Type -------------- 1 OPEN AIR 2 12 AWG Trunk Cable 90°C 30 O96 1 28,80 13 1 1,25 1&25 12 AWG Trunk Cable PROJECT INFORMATION 2A 10 AWG THWN-2 75°C 35 0.96 26,88 13 1 1,25 16,25 08 AWG THWN-2 INITIAL DATE: 1/11/2022 DESIGNER: NB 3/4" PVC 4 — 0.8 REV: DATE: DESIGNER: 28-80 NOC 'A' 1 26 '8 1 ...... - EV.�. :T :HW:N :-2 26 DATE: DESIGNER: 2B 10 AWG THWN-2 75°C 35 O�96 26�88 13 1 1.25 16.25 08 AWG THWN-2 3 3/4" PVC 3 + G 08 AWG THWN-2 75°C^ 50 0,96 1 48.00 26 1 1.25 32.50 08 AWG THWN-2 THREE LINE DIAGRAM 4 3/4" PVC 3 THWN-2 75°C 65 O�96 71 26 ['HWN-2 - 06 AWG 62.40 PV-3 NOTE. �LETTE�RG' IN WIRE �QTY TAB F®RGRO�UNDINGCON CTO�R����� ELECTRICAL NOTES: 1. ALL CALCULATIONS FOR VOC, VMAX, IMP AND ISO HAVE BEEN CALCULATED USING THE MANUFACTURED STRING CALCULATOR BASED ON ASH E 2% HIGH AND EXTREME MINIMUM TEMPERATURE COEFFICIENTS. 2, THE ENTIRE ARRAY IS BONDED ACCORDING TO (NEC 690A6 - 250,120 PARAGRAPH C). THE GROUND IS CARRIED AWAY FROM THE GROUNDING LUG USING #6 BARE COPPER WIRE OR #8 THWN-2 COPP WIRE. I 3. THIS SYSTEM COMPLIES WITH NEC 2017 i 5. ALL CONDUCTORS ARE SIZED BASED ON NEC 2017 ARTICLE 310 6. ALL EQUIPMENT INSTALLED IS RATED AT 75°C 7. INVERTER NOC (NOMINAL OPEN CURRENT) OBTAINED FROM EQUIPMENT DATASHEET 8. CONTRACTOR SHALL BE RESPONSIBLE: FOR COMPLYING WITH ALL LOCAL AND NATIONAL CODE REQUIREMENTS. 9. EACH MODULE MUST BE GROUNDED ACCORDING TO USER INSTRUCTIONS 10, ALL EQUIPMENT SHALL BE LISTED PER NEC 690.4(B) TERMINALS11, PER NEC 690,13,690,15, PROVIDE A WARNING SIGN AT ALL LOCATIO WHERE TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION> SIGN SHALL READ *WARNING - ELECTRIC SHOCK HAZARD - DO NOT TOUCH EQUIVALENT. I 12. PER NEC 705.10, PROVIDE A PERMANENT PLAQUE OR DIRECTORY SHOWING ALL ELECTRIC POWER SOURCES ON THE PREMISES AT SERVICE ENTRANCE. 13, INTERCONNECTION METHOD SHALL COMPLY WITH NEC 705,12 14. AND OPTION FOR A SINGLE CIRCUIT BRANCH TO BE SPLIT INTO TWO SUB -CIRCUIT BRANCHES IS ACCEPTABLE. 15, ALL CONDUCTORS MUST BE COPPER. 16. NEUTRAL AND EQUIPMENT GROUNDING CONDUCTOR BONDED AS PER NEC 250.24(C), 17. EQUIPMENT GROUNDING CONDUCTOR 1S CONNECTED TO A GROUNDING ELECTRODE SYSTEM PER 250.54(D). 18. FUSES FOR PV DISCONNECT HAVE AIC RATINGS OF 200KA AC AND 20KA DC. 19. SUPPLY SIDE CONNECTION SHALL BE MADE USING ILSCO INSULATION PIERCING CONNECTORS (IPC). MAKE, MODEL, AND RATING OF INTERCONNECTION CAN BE SEEN ON TABLE 1 BELOW. 20. METHOD OF INTERCONNECTION CAN BE SEEN IN FIGURE 1. 21. UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 22, WORKING CLEARANCES AROUND THE EXISTING AND NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC ARTICLE 110.26, 23. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC ARTICLE 300,E (C)(1) AND ARTICLE 310.8 (D). 24. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C). 25. TOTAL AREA OF ALL CONDUCTORS, SPLICES, AND TAPS INSTALLED AT ANY CROSS SECTION OF THE WIRING DOES NOT EXCEED 75% OF THE CROSS SECTIONAL AREA OF THE SPACE. NEC 312.8(A)(2). 26. SYSTEM IS CONSIDERED AN AC MODULE SYSTEM. NO DO CONDUCTORS ARE PRESENT IN CONDUIT, COMBINER, JUNCTION BOX, DISCONNECT. AND COMPLIES WITH 690.E - NO DC DISCONNECT AND ASSOCIATED DC LABELING ARE REQUIRED. 2T SYSTEM COMPLIES WITH 690.12 RAPID SHUTDOWN AND ASSOCIATED LABELING AS PER 690.56(C), AC VOLTAGE AND SYSTEM OPERATING CURRENT SHALL BE PROVIDED 690.52. 28. CONDUCTORS IN CONDUIT ARE AC CONDUCTORS BRANCH CIRCUITS AND NOT PV SOURCE CIRCUITS, 690.6. 29, ALL GROUNDING SHALL COMPLY WITH 690.47(A) IN THAT THE AC MODULES WILL COMPLY WITH 250.64. 30. NO TERMINALS SHALL BE ENERGIZED IN THE OPEN POSITION IN THIS AC MODULE SYSTEM 690,13, 690,15, 690.6, 31. WHERE APPLICABLE: INTERCONNECTION SHALL COMPLY WITH 705.12(A) OR 705.12(B) fill 2F.4 TABLE Ie VOLTAGE CONDUCTOR CONDUCTOR MAKE MODEL TING RANGE MAIN RANGE TAP ILSCO IPC 4006 600 V 4/0-4 AWG 6-14 AWG ILSCO IPC 4020 600 V 4/0-2 AWG 2/0-6 AWG CABLE,FIGURE 1: 1. ADJUST THE CONNECTOR NUT TO SUITABLE LOCATION 2, PUT THE BRANCH WIRE INTO THE CAP SHEATH FULLY 3. INSERT THE MAIN WIRE, IF THERE ARE TWO LAYS OF INSULATED LAY IN THE MAIN SCREWLENGTH OF THE FIRST INSULATED LAY FROM INSERTED END 4TURN THE NUT BY HAND, AND FIX THE CONNECTOR IN SUITABLE LOCATION. THE TOP PART IS CRACKED 6. SCREW THE NUT CONTINUALLY UNTIL DROPPED DOWN L V momentum SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 (732)902-6224 MOMENTUMSOLAR.COM �� glul �II CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 am �� IM K340 IINITIAL IDATE: 1/11/2022 1DESIGNER: NB I REV: DATE: DESIGNER: REV: I DATE: DESIGNER: SYSTEM INFORMATION ROOFTECHgi II 11 / ECOFASTEN CLICKED RAIL RACKING SYSTEM K 0 ROOF SHALL HAVE NO MORE THAN TWO LAYERS OF COVERING IN ADDITION TO Z SOLAR EQUIPMENT. SYSTEM UTILIZES "ENPHASE" MICRO -INVERTERS WITH RAPID SHUTDOWN CONTROL LOCATED ON THE BACK SIDE OF EACH MODULE. ' f" t, STRUCTURETHE EXISTING • BY PHOTOVOLTAICTHE RAFTER SIZES w DIMENSIONS CONFORM TO 7TH EDITION 2020 FLORIDAa'SIDENTIAL . s { s SPEED, TOPOGRAPHIC EFFECTS SPECIAL WIND REGION WIND BORNE DEBRIS ZONE SEISMIC DESIGN CATEGORY CLIMATE ZONE WIND EXPOSURE FBC, RESIDENTIAL. 2020 TABLE 31 n2s1 e3 WIND SPEED CONVERSIONSa V,I 110 115 120 130 140 150 160 170 130 100 200 �asd 8 a �9 �33 101 10� 11 �'i 124 132 139 147 155 For SI; 1 mile per hour = 0.447 m/s. a. Linear interpolation is permitted, KEY COVERPAGE ATTACHMENTPLAN ROOF LAYOUT ELECTRICAL CONT. EQUIPMENT LABELS BILL OF MATERIALS MODULES 25 INVERTERS 25 L-FOOT ATTACHMENT W/ RT-MINI 44 168" RAILS 11 SKIRTS 9 ENPHASE COMBINER BOX 1 EATON 60A FUSIBLE AC DISCONNECT 1 35A FUSES 2 125A LINE TAPS 2 0 momentum PRO CUSTOM SOLAR LLC D.B.A. MOWNTUM SOLAR 325 HIGH STPEET, METUCHEN, N3 08840 (732) 2-6224 MOVENTUMSOLAFLCOM CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMIENYUM SOLAR 5728 MAJOR BLVD, SUITE 307, ORLANDO FL. 328F9 ° fkl PER MODULE WSTALLARON M.ANU. SECTION A -A 0.79 1,57 1 1 1,50 "*0' 138ol 2,76 [70.1) DETAIL C DETAIL D FROW ViEw SIDE VIEW SCALE 1 :6 SCALE I: 6 L-FOOT L-FOOT tgeRvaer C4M AND TOLmno-C )0 NOT SCALE DRA PER A—Wf Yak -2009 M: 030 X.1 75 1,57 [4o0] CLICKFIT COMP SHINGLE T'XX-XXXX-XXX I Dual bolt design: M8 or 5116" for L-Foot & 114,' for EMC WX ICC ESR 3575 Call NGw fGr more details 858-935-6064 Engineered to ASTM D 1761 is-i--, �-v ik. W—) -----Components RT2-OD-MINJOK optionsi Awn 5 x 100 a ,Ba 100-18.9 RT RT2-04-IKITYLT} 10-A. by KX-, wt.1 Fl.shmg Rt,.ht Flexible Flashing 1<5 a Shedd ig water? 100% Waterproof r-C ESR-3575 ASTM2140 testkg UV testing (TWO hra) INVI'lip 0610,1- 1 To j 31/2 190 Rafter installation 0 momentum PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, N3 08840 (732) 902-6224 MOMENTUMSOtAR.COM CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 KA3OR BLVD. SUITE 307, ORLANDO FL. 32819 -38-7--5,2 F HERING11 WAY-, I FZLLS, h/J3542 2402465428 W99 "aul W 01 vim M" BLK-G10+ 360 Ulm REV: I DATE: I DESIGNER: PV MODULE RATINGS INVERTER RATINGS VOLTAGE DROP CALCULATIONS FORMULA USED PER NEC HANDBOOK 215.2(A)(4) WHERE APPLICABLE if - momentum Q,PEAK DUO WIRE V-P I-P R L( VO % V, WIRE SIZE MODEL BLK-G10+ 360 MODEL K17-60-2-US SOLAR 19,8 MAX POWER 36OW MAX OUTPUT POWER 240W BRANCH TOBOX 240.00 16 1.98 105,33 6.674 2.78% 12 AWG PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3-BOX TO LOAD 325 HIGH STREET, METUCHEN, NJ 0880 1 - V 6 D 74 rW(1,RE SIZE SI 2 AWG OPEN CIRCUIT VOLTAGE 41.18V OPEN DC VOLTAGE 48V 240.00 25 1.24 50.00 3.100 1.29% 10 AWG (732) 902-6224 CENTER MOWNTUMSOLAR.COM DPP VOLTAGE 34.31V NOMINAL AC VOLTAGE 240V LOAD CENTE TO f 0 02— 240.00 31.25 0.778 3.00 0.146 0.06% 08 AWG PROFESSIONAL MORT CIRCUIT CURRENT 11.04A MAX AC CURRENT 1A DISCONNE' ENGINEERING C CO T 00 0 MPP CURRENT 10.49A AC DISCONN TO 11 1C CEC INVERTER EFFICIENCY 97% INT CO 0 240 . 31,25 0.491 10.00 !0.307 06 AWG INTERCONN ION NUMBER OF MODULES 25 NUMBER OF INVERTERS 25 --------------- -------- --------------- U 111 17n1_rnU01 IAWT VVI. L1703 COMPLIANT YES 1703 COMPLIANT YES SUB PANEL # OF MODULES PER BRANCH THIS SOLAR PHOTOVOLTAIC SYSTEM COMPLIES WITH�E 2020 RA BREAKER SIZE FLORIDA BUILDING CODE AND THE 2017 NATIONAL EL CTRICAL CODE till III E��= :7 =20A A - UP TO 16 FSEC CERTIFICATION STATEMENT' ­4 PER FL. STATUE 377,705, 1, MINA A. MA PE # 867538 25 HANWHA Q.PEAK DUO BLK-G10+ 360 36OW K40DULES PAIRED WITH CERTIFICATE OF AUTHORIZATION #33404, AN ENGINEER 25 ENPHASE IQ7-60-2-US MICRO -INVERTERS LICENSED PURSUANT TO CHAPTER 471,CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED =-0 I -': IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING 0 F CODE. FBC 2020 .10 TAT ' ��% * BRANCH CIRCUIT A EXISTING GENERAL �6 MICRO -INVERTERS ELECTRIC 200A MAIN '//S�fONA1. BRANCH CIRCUIT B SERVICE PANEL 240 V /1111111100 9 MICRO -INVERTERS MAIN BREAKER: 200A '\1__ "I'll, "I/ LINE SIDE 11 11 - ENPHASE80A SOLAR HOT TAP AC COMBINER CIRCUIT T BOX DISCONNECTING MEANS 200A EATON 60A FUSIBLE AC 7 DISCONNECT ------------ IL - ---------- - --------- L ROOF 5A BREAKER I OA/1 5A JUNCTION tjr- Lj- 1�17ZWER (MANUFACTURER 'T 35A FUSES GROUND 1 BOX SUPPLIED FOR 2A-B 3 4 TERMINATION CAP ENVOY) INSTALLED ON 20A BREAKER (A) END OF CABLE 20A BREAKER (B) Wire Tag Conduit Wire City Wire Wire Type Temp. Gauge Rating I OPEN AIR 2 12 AWG Trunk Cable 901C 2 A 10 AWG THWN-2 75°C 3/4" PVC 4 — 2B 10 AWG THWN-2 75°C 3 3/4" PVC 3 + G 08 AWG THWN-2 —F75'C 4 3/4" PVC 3 06 AWG THWN-2 75 C NOTE: LETTER "G" IN WIRE QTY TAB STANDS FOR GROUNDING CONDUCTOR. Wire Temp. Conduit Derated Ampacity (A) Derate Fill Karate Ampacity (A) 30 0.96 1 28.80 35 0,96 26.88 0�8 35 0.96 26,88 50 0.96 1 48.00 65 0,96 1 62,40 Inverter NOC (A) NEC Design Qty Correction Current (A) 16 1 1.25 20.00 16 1 1.25 20.00 9 1 1.25 11,25 25 1 1,25 31.25 25 1 1.25 31.25 CAMERON CHRISTENSEN CE&MHED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAIM BLVD. SUITE 307, ORLANDO FL, 32819 BLK-G10+ 360 Ground Ground Wire Size Type 12 AWG Trunk Cable -PR03ECT 114FOR14A 08 AWG THWN-2 INITIAL DATE: 1/24/2022 DESIGNER: N8 REV. DATE: DESIGNER: 08 AWG THWN-2 RE,: DATE: DESIGNER: 08 AWG THWN-2 THREE LINE DIAGRAM THWN-2 I PV-3 y CALCULATIONS1. ALL CALCULATED USING THE MANUFACTURED STRING CALCULATOR BASED ON ASHRAE 2% HIGH AND EXTREME MINIMUM TEMPERATURE 2fHE ENTIRE ARRAY IS BONDED ACCORDING TO (NEC 690.46 - 250 *,20 PARAGRAPH C). THE GROUND IS CARRIED AWAY FROM THE GROUNDING LUG USING #6 BARE c e . THIS SYSTEM COMPLIES WITH NEC 217 5. ALL CONDUCTORS ARE SIZED BASED ON NEC 2017 ARTICLE 310 * ALL EQUIPMENT INSTALLED IS RATED AT 75°C 7. INVERTER N (NOMINAL OPEN CURRENT) OBTAINED FROM EQUIPMENT DAT HEET 6. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL LOCAL AND NATIONAL CODE REQUIREMENTS. 9. EACH MODULE MUST BE GROUNDED ACCORDING TO USER INSTRUCTIONS 10. ALL EQUIPMENT SHALL BE LISTED PER NEC 690.4(S) 11. PER NEC 690.13,690.15, PROVIDE A WARNING SIGN AT ALL LOCATIONS WHERE TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION> SIGN SHALL READ *WARNING - ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS - OR 12, PER NEC 705.10, PROVIDE A PERMANENT PLAQUE OR DIRECTORY SHOWING ALL ELECTRIC POWER SOURCES ON THE PREMISES AT SERVICE ENTRANCE, 13. INTERCONNECTION METHOD SHALL COMPLY WITH NEC 705.12 14. AND OPTION FOR A SINGLE CIRCUIT BRANCH TO BE SPLIT INTO TWO SUS -CIRCUIT BRANCHES IS ACCEPTABLE. 15. ALL CONDUCTORS MUST BE COPPER. 16. NEUTRAL AND EQUIPMENT GROUNDING CONDUCTOR BONDED AS PER NEC 250.24(C). 17. EQUIPMENT GROUNDING CONDUCTOR IS CONNECTED TO A GROUNDING ELECTRODE SYSTEM PER 250.54(D). 18. FUSES FOR PV DISCONNECT HAVE AIC RATINGS OF 200KA AC AND 20KA DC. 19. SUPPLY SIDE CONNECTION SHALL BE MADE USING ILSCO INSULATION PIERCING CONNECTORS (IPC). MAKE, MODEL, AND RATING OF INTERCONNECTION CAN BE SEEN ON TABLE 1 BELOW. 20. METHOD OF INTERCONNECTION CAN BE SEEN IN FIGURE 1, 21. UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. JL_�V�OLTA RA RN TI 2/0-6 AWG d FIGURE 1: 1 . ADJUST THE CONNECTOR NUT TO SUITABLE LOCATION 2. PUT THE BRANCH WIRE INTO THE P 3. INSERT THE MAIN WIRE, IF THERE SHEATH FULLY INSULATEDTWO LAYS OF LENGTH OF THE FIRST INSULATED LAY FROM INSERTED END 4, TURN THE NUT BY HAND, MAIN CABLE, SHOULD STRIP A CERTAIN SPANNER.CONNECTOR IN SUITABLE LOCATION, 5. SCREW THE NUT WITH THE SLEEVE 6. SCREW THE NUT CONTINUALLY UNTIL THE Y PART IS CRACKED AND DROPPED DOWN SOLARmomentum 325 ljR STREET, a! 4 PROFESSIONAL ENGINEERING My III g 4)tj STAT E OF ` P4 R V CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOME M M SOLAR 5728 MA3OR BLVD. SUITE 307, ORLANDO FL. 32819 ICARDO HERNANDEZ AROCHO - M592413 IREV: IDATE: [DESIGNER: 1 BREAKING THE 20 % EFFICIENCY BARRIER Q,ANTUV1 DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9 %. THE MOST THOROU13H TES TING, PROGRAMME IN THE INDUSTRY Q CELLS is the first solar module manufacturer to pass the most comprehen- ,7_�4sine quality programme in the industry: The new 'Quality Controlled PV" of the independent certification institute TOV Rheinland. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low -light and temperature behaviour, ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology, Anti PID Technology', Hot -Spot Protect and Traceable Quality Tra,QTm. EXTREIME WEATHER RATING High-tech aluminium alloy frame, certified for high snow (5400 Pa) and wind loads (4000 Pa). A RELIABLE INVESTMENT Inclusive 25-year product warranty and 25-year linear performance warranty2. APT test conditions according to 1EC/TS 62804-1:2015, method A (-1500V, 96h) See data sheet on rear for further information. THE IDEAL SOLUTION FOR: aRooftop arrays on residential buildings Engineered in Germany OCELLS MECHANICAL SPECIFICATION 1717mm x 1045 mm x 32mm (including frame) 19.9 kg aao min _- ses.e�„ 3.2,,)m thermally pre -stressed glass with wA + _ a anti -reflection technology _. a,cr«,nau,p�me®, Composite film e Black anodised aluminum xonxsn n, 6 x 20 monocrystalline Q.ANTUM solar half cells ® x e, , 53-101mm x 32-60mm x 15-18 min Protection class IP67, with bypass diodes �he� nsn n,e, 4mm� Solar cable, (+) :z1150mm, (-)>_1150mm 9 xMen9ngabro ... ... Staubll MC4, IP68 .... oe at Ay 8 x Prax•a@a trolea DETAIL 18 mm� zxzsmm-r -i T-a 5.,n, ELECTRICAL CHARACTERISTICS POWER CLASS t. 350 355 360 365 370 P,,,,,,, [W] 350 355 360 365 370 _ Isc [A) 10.97 11,00 11,04 11,07 ,...... ...... ­'_ 11.10 _... Vic IV] - ..... . _. ... _,_ ,_ 41.11 . ,.... 41.14 . 41.18 ... , .. 41.21 --__-_.- . .-. 41.24 -..... In" [A] 10.37 „_. ._v-_ -.�... 1043 __- .__-___ 10.49 10.56 -- 10.62 _. Vr,vu IV] 33,76 mm..m..-.w.., 34.03 .L.. wa�_.. ..m,.-_._w 34.31 34.58 -. .._...m._. 3484 [%] x19.5 - 2!19.8 �:201 - ..,. _20.3 _�_ z20.6 ......-..._ ..._ P [W] _ 262.E 266.3 270.1 273.8 .. 2776 Is, [A] 8,84 8.87 -- ------ --- 8,89 ....._-- 8.92 _..... 8,96 _.- VOc IV] 38,77 38.80 _ . ... _ ............ ... ........... ... 38.83 ... 38.86 ,.......... 38.90 ... - _ p [A] 8.14 8.20 8,26 8.31 8.37 Vre", IV] 3224 32,48 3271 32.94 33.17 _., ..... ... __ .. ....-.. _.-.- -Measurement tolerances Pdpr 3 % Is, ; Vc,', 5% at STC 1000 W/mT 25t2 °C, AM 15 according to IEC 60904-3 > 1800 W/ma, NMOT, spectrum AM 1.5 ....... _..... .... ....._..._... .., _.. _... _..., . ,,.. _... ...........___.... . ___,...__ .-._..._....__...._ . ___.......... .. _.----------- Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE .. TEMPERATURE COEFFICIENTS At least 98 % of nominal power dur- ing first year. Thereafter max. 0.5% degradation per year. At least 93.5 % of nominal power up to 10 years. At least 86 % of nominal power up to 25 years. All data within measurement toler- ances. Full warranties in accordance with the warranty terms of the Q CELLS sales organisation of your respective country. e--r-------------- - i i 80 � I 300 4" $00 @n0 1w Typical module performance under low irradiance conditions in comparison to STC conditions (25°C, 1000 W/mg. a [%/K] +0.04 0 [%/K] -0.27 y [%!K) -0.34 - _-.. NMOT [eC] 433 PROPERTIES FOR SYSTEM DESIGN IV) 1000 Class II [A] 20 . , . ... ., A! ., . C/TYPE 2 (Pa] [Pa] ' �, AND CERTIFICATES (A-ity C t Iled PV TUV RheInland IEC 61215 20IEC 617302 16. r- This data h t tannpivs with DIN EN 50380. QCPV Cert; canon ohg.ngis 3600/2660 5400/4000� -40°C -+85eC Nate: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product_ Hari 0 DELLS GmbH Sonnenallee 17-21, 06766 Bitterfeld-Wotfen, Germany I TEL+49 (0)349466 99-234441 FAX +49 (0)3494 6699-23000 1 EMAIL sales@q-celis.com I WEB www.q-cells.com Engineered in Germany OCELLS