Loading...
HomeMy WebLinkAbout22-3535City of Zephyrhilis yy l t 5335 Eighth Street zr3y��� t7y1 ,yi y�z�.,tz3x�;..y 1���:�5��{��<i $''�'�,.�i`���ht ephyrhiifs, FL 3542 Phone: (313) 730-00 0 Fax: (313) 730-0021 Issue ®ate: 01/28/2022 26 25 21 0140 00200 0030 8126 Wheat Stone Drive t .'.: \•���: ?ityE,tt,,, �� },;.. `z, s��k;; �`� �``;;:,?'\ tt �. �zt \�,� � \r *.t ,t. ttiypl„. , �, �...:;`>>.. ,r, 3\� � �'x� � �`���,'"i3\ t'�SE '., � n�i� x\ti�y� i;<. ^}\ :, ?i4 � t`.,'•q,;11 �,,, ,,�. ii Name: MONIQUE SANTINI Permit Type: Electric Service Replacement/M Contractor: MOMENTUM SOLAR - Class of Work: Add/Alter Residential SOLAR Address: 8126 Wheat Stone rh Phone: (813) 245-3576 Building Valuation: $0.00 Electrical Valuation: $28,560.00 Mechanical Valuation: Plumbing Valuation: Total Valuation: $28,560.00 Total Fees: $182.80 Amount Paid: $182.80 Date Paid: 1/28/2022 11:03:43AM REINSPECTIONR Reinspection fees will comply with Florida Statute 553.80(2)(c) the governmentlocal impose times imposedo first reinspection,subsequent pe: Notice: In addition to the requirements of this permit, there may be additional • property foundmay be records of this county, and there may be additionalpermit required from other governmental management,entities such as water i OCCUPANCYaccordance with City Codes and Ordinances. NO OCCUPANCY BEFOREc.6. NO BEFORE C.O. t CONTRACTOR SIGNATURE v i - NPE I T 0 F�E 16 ;EUj mmm� City of Zephyrhillp Permit Application Building Department' 321 247 6073 W.�r QUESANTI'NI Ownees Address Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Add I JOB ADDRESS 1/8126 EAT STONE DR LOT # SU13DIVISION PHYR LAKES PARCEL iD#L26-25-21-0140-00200-0030 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD/ALT SIGN DEMOLISH M INSTALL REPAIR PROPOSED USE SFR COMM OTHER TYPE OF CONSTRUCTION BLOCK FRAME STEEL A , I * Fr%E-4WA1FZK'b4fie3RW* BUILDING SIZE SO FOOTAGE HEIGHT [::= X k IE AEIUIU�W k 3UW- X X X X 1EX XX1E1U1EkX XXXVIL]EXIE IL C41EX 1E]EXIE V X X YEW 1EX IL It CICILIEXXXX XXXIck Ew C Clel =BUILDING r== VALUATION OF TOTAL CONSTRUCTION 28,560 E]ELECTRICAL 1$28,560 1 AMP SERVICE PROGRESS ENERGY = W.R.E.C. L.� ? =PLUMBING ----------------- re =MECHANICAL VALUATION OF MECHANICAL INSTALLATION =GAS ROOFING = SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA F--1YES NO BUILDER � �� ` �� COMP Y Momentum Solar SIGNATURE � �- `� Cameron Christensen REGISTERED Y t N_�" FEE CURREN Y / Address 6210 Haffner Ave Ste 100 Orlando FL 32822 License# I CVC57036 ELECTRICIAN COMPANY [ Momentum Solar SIGNATURE Matthew Franz REGISTERED L�Y! N -FEE C6_RREN L_yy N_J Address 6210 Haffner Ave Ste 100 Orlando FL 32822 License # PLUMBER COMPANY E SIGNATURE REGISTERED ;;�IEE .RREII Address E========= License #E===== MECHANICAL COMPANY E SIGNATURE F=:== REGISTERED ;;;;: �FEECURRENI N�� Address License # OTHER COMPANY SIGNATURE REGISTERED L=Y1 =N FEECU=RREN Address License #E==:=== RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for now construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Slit Fence installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms, R-O-W Permit for new construction. Minimum ten (10) working days after submittal date, Required onsite, Construction Plans, Stormwater Plans w/ Slit Fence installed, Sanitary Facilities & I dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans, ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign back of application, notarized if over $2500, a Notice of Commencement Is required. (A/C upgrades over $7500) Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences (PloVSurvey/Footage) Driveways -Not over Counter if on public roadways..needs ROW Permit Number FollolParcel ID Prepared by: State of Florida, County of - Pasco The undemIgned hereby gives notice that Improvement YAII be made to cerb* real property, and In accordance with Chapter 713, Florida SUrlutes, the ibilowing information is pvvkled in this Notice, of Commencement 1. Description of property (legal description of the property, and street address If evallable) 8126 Wheat Stone Dr ZEPV,Yf-U,,KES SUBDIVIS101A RUISES 1A 2A 28 &4A BLOCK 2 LOT 3 11ft,719 tloniaue I.Ialdov,?do Nam Address 4. Nam lephone, Number 121-247-8073 Address ,5. surety iff appilas a copy of the paymerd bond Is attedmd) Name WA Telephone Number_ Address —Amount of Bond 6. Lender Nam ne Number Addnws 7. Person ior documents may Via,', served as provided by 1713.13(i)(m)7, Florida Statutes. Name MA --Telephone Numbw�__ sddftkm to hlm*W or- he- roe —the -1-6­111ir—Mngto reme-N-v -a copy of the Us"oes Rofte as provided In 1713,13(l)ft Flodds Stinutes. NamP-MA.......Totephone NuZrnber Address 77 = f record ve 'It's 9. Expiration date of notice of commenconent (the wpirstion date vAD be I year from the date of recording unless a dMemnt date is specified) __--��7_113=22 The foregoing Instrument was acknowledged before me by mearts of (I phyelcalpresenceorf ]online notarization, this _U_ day of A&lL2Z_by onique Maldona o Mwof ration as Owner for Type 7oaufttftr,,PK*r, ~, —ftdftwo, *10onmy In fed -Gam-e-Wp�artyon bo�hffof wf.�xnh*w�wtwss =�wuftd Ignoture of Notoy PuW - Stals of Florida pmt tyw. or �M'M of Mok-Y Wk Personally Mown _QR Produced ID X M 11 i M 9 Two of 10 Produced Driver's LkNum 0=9 I ELI tate of I rl a- 0 Pub ml 9 n 179362 Potm owdeM revind: 01101M C C solo" fit j a 813-780-0020 City of Zephyrhills Oermit Application Fax-813-780-0021 Building Department ' NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to 'deed' restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009, Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractors) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner' prior to commencement, CONTRACTOR'SIOWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, WaterAA/astewater Treatment, Southwest Florida Water Management District -Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers -Seawalls, Docks, Navigable Waterways, Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency -Asbestos abatement. Federal Aviation Authority -Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone "V'unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction, I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a pennit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or Violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a pared not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned, FLORIDA JURAT (F.S. 117,03) OWNER OR AGENT Subscribed and sworn to (or affinned) before me this by Who —is/are personally known to me or has/have produced as identification. Notary Public Commission No. Name of Notary typed, printed or stamped 11 IZANIMILLIMMIMM121L CONTRACTOR S qyd sworn to (or affirmed) before me this An, 13 29 2 b he is/air me or has/have produced as identification. oa Notary Public Corn4ssion No. ELIZABETH DINO Warne of Notary typed, printed or stamped E L I ETH DINO P State Of Florida -Notary Public Commission # GG 178362 MY Commission Expires 2 January 24, 2 BREAKING THE 20% EFFICIENCY BARRIER Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9%. THE MOST THOROUGH TESTING PROGWANIME IT THE INDUSTRY Q CELLS is the first solar module manufacturer to pass the most comprehen- sive quality programme in the industry: The new 'Quality Controlled PVof the independent certification institute TOV Rheinland. INNOVATIVE ALL­WEAVI HER TECHNOLOGY Optimal yields, whatever the weather with excellent low -light and temperature behaviour, ENDURING,1flGH PERFORMANCE Long-term yield security with Anti LID Technology, Anti PID Technology', Not Spot Protect and Traceable Quality Tra,QTM, EXTREME WEATHER RAT ING ZZ High-tech aluminium alloy frame, certified for high snow (5400Pa) and wind loads (4000 Pa), raj A RELIABLE INVESTMENT Inclusive 25-year product warranty and 25-year linear performance warranty2. APT test conditions according to I EC/TS 62804-1:20I5, method A (-1500V, 96h) 2 See data sheet on rear for further informaron. THE IDEAL SOLUTION FOR: Rooftop arrays on residential buildiefis Engineered in Germany GICELLS MECHANlCAL SPECiFlICATION ---- ----- -- ----------- Format 1717mm x 1045mm x 32mm (including frame) Weight 19.9kg Front Cove, 3.2mm thermally pre -stressed glass with anti reflection technology Back Cover Composite film Prime Black anodised aluminium Cell 6 x 20 monocrystalline Q.ANTUM solar half cells Junction box 53-101mm x 32-60mm x 15-18 mm Protection class IP67, with bypass diodes Cable 4 mm2 Solar cable; x 1150 man, I-) a 1150 arm Connecto, Staudt MCA; IP68 J .... ......... ... ELECTRICAL CHARACTERISTICS ........... ---- - ----- - ---- --------------- POWER CLASS 350 355 360 11111-1­1- 1-1-1--l-1­1 .. ......... ... .. .. ........... ... .. ... ... . ..... .... .. .... ..... ........... - - 365 370 . . . MINIMUM PFRPORMANCE AT STANDARD TEST CONDITIONS, STC1 (POWFR TOt,FRANCF +5W OW) ...... .. .... Sewn, at IX1 PIP, P.Pl, IWI 350 355 360 . 365 370 ... ........ .. ........................ . .. ........ .. .. ... ... .. .. .... ... ......... ...... .... . .... . . ............. . . ......... .. .......... .... . Short Circuit Current' I'll (A] 10,97 11.00 11.04 P 11-07 11A0 Open Circuit Vopnqe' V.x IV] 41�11 4114 4118 ..... ..... ......... .. 41.21 41.24 .. ......... E Current it MPP I., fAj 10.37 10.43 10.49 1056 10.62 I Voltage it Mpp V.11 IV] 33.76 34�03 34.31 34,58 34,84 ......... .. -------- -------- - ---- ..... ........ ....... ... . Efficiency' [%] z 19.5 19.8 20.1 ........ .. ......... a20,3 a21 NIINIMU M PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOTI Power 0 IN PP Prin' [Wl_ 262�6 266,3 27111 273.8 2776 ­111-1-111 11 -1 1111.1 - ---------- ------- E Short Circuit Current la, fAj 8,84 8.87 8,89 . -------------- - - ---- -- ----- ---- -- 892 &95 ... ..... ........................ ... ............. ...... .. .. ... ...... ...... ... .. .... ..... ... ..... .E Open Circult Voltaqo V_ IV) 38�77 38.80 38.83 . 38.86 38,90 ... .... ........ .. . . .. .......... --- ------- ----- ------ - ---- ---------------- --- - -- ---------- ---- - - --- - - Current at MPP 1.11[A] 8.14 820 8.26 . ....... 8.31 Voltage atOPP VmPP 32.24 32.48 32,71 ----------, --_­­-. .. --8.37 3294 33.17 ......-------- Measurement tolerances P_ 3 % Isr.. V_ t 5 % at STO 1000 WInnu, 25t 2'C, AM 1.5 according to 1 EC 60 904-3 - 1800 W/ml, N M OT, spectrum AM 15 ----- ---- - Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE .... ........ ..... ....... ......... .. .. .. .............. . .. ..... ....... . .... ...... .......... ------- ---- ---- At least 98% of norturah power dur- Ing first year. Thereafter max, 0.5% degradation per year At least 93.5% sar----- ------ ------ of nominal Power LIP to 10 years, At T least 86% of normina! Power LIP to 25 years, rx u All date within measurement toler- ances. Full warranties in accordance Le with the warranty terms of the IRRAGIANCE Q CELLS sales orgairlsation of your Mu,hll respective country, yux" Typical module performance under low irradlance conditions in comparison to STC conditions (25 OC, 1000WImr, - -- . .... ... - - - ----- --- ----- ------ - ------ -- - ----- --- TEMPERATURE COEFFICIENTS rempe'atuna C"Oficient of a [%/Kl +0,04 Temperature Coefficient of V_ 0 ... ..... ..... . ... ------ --- ------- ------- -- ----- --- 1­11 -------------- - (%/Kl -0.27 Temperature Coefficient of P_ y [%/Kl -Q34 Nominal Module Opernfinq Temperature NMOT [C] 43±3 PROPERTIES FOR SYSTEM DESIGN Maximum sy,uom Vratage VIYI IV] 1000 PV module classification cis," It - 11 1 "1 I'll 11, '­ .. .. .... .. ...... ... . ......... -- -------- --- ------------ Maximum Reverse Current 1, tAI 20 Fire Rating based or ANSI IUL 61730 C/TYPE 2 Mox. DesirIn Load, Push/Pull 3600/2660 [Pa] PeIrmitted Moortie Temperature -40'C - 85'C ..... .... ...... "I ­­­ - ­­­­ I'll, "I I ­ ­­ ­11-1 ­­ ­1­11-11- ­111 1--l-1-1111111-1 C Max. Test Lcoo, Push / Pull [Pa] 5400/4000 on onfinuous Duty ............ ­­ .............. ...... . .... ........ .... --- - ----- ---- - -- - . ....... ....... .... ............ QUALIFICATIONS AND CERTWiCATES Qra xy C.1sc,ed PV - TOV RhOu ec; IEC 61218:2016; iEC 6,..18. This eats sheet complies With DIN EN 50380, Dash ceulft.stlon ongoing.0 E Nate: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Hanwhe 0 CELLS GmbH Sonrenallee 17-21,06766 Bitterfeld-Wolfien, Germany I TEL +49 (0)3494 66 99-234441 FAX +49 (166 99-230001 EDAM sties@LT-cellsoom I WEB,' www,q-colls.com Engineered in Germany OCELLS SYSTEM INFORMATION MODULE FIANWHA Q.PEAK DUO BL -%6+ 340 INVERTFR ENPHASE I 7-60-2-US RACKING R OFT"E H MITI & ECOFASTEN CLICKFIT SYSTEM 2-RAIL SYSTEM SIZE (D) 7,14 K LOCATION 28.27691131- 2.1831 57 # T # ROOF SHALL HAVE NO MORE THAN TWO LAYERS OF COVERING IN ADDITION TO THE SOLAR EQUIPMENT. ANY PLUMBING VENTS ARE NOT TO BE CUT OR COVERED FOR SOLAR EQUIPMENT INSTALLATION. ANY RELOCATION OR MODIFICATION OF THE VENT REQUIRES A PLUMBING PERMIT AND INSPECTION. RAPIDSYSTEM UTILIZES "ENPHASE" MICRO -INVERTERS WITH CONTROL STRUCTURALLOCATED ON THE BACK SIDE OF EACH MODULE. STATEMENT: THE EXISTING STRUCTURE IS ADEQUATE SUPPORT THE NEW L F# ...' THE PHOTOVOLTAIC MODULE SYSTEM INCLUDING UPLIFT & SHEAR.EXISTING RAFTER DS IMPOSED BY k # CLIMATIC & GEOGRAPHIC DESIGN CRITERIA TABLE R301,2(1) SPEED (ICI) 14 TOPOGRAPHIC EFFECTS R SPECIAL WIND REGION NO WIND BRIE DEBRIS ZONE 2 SEISMIC DESIGN CATEGORY C CLIMATE ZONE 2A IUD EXPOSURE CAT'ET° RY R FBC, PE II E ITIAL 2020 TABLE3.2..3 WIND SPEED CO.t-11VERSIONSa Vint 110 115 120 130 140 150 1 0 170 130 190 00 asd 35 89 3 101 106 116 124 12139 147155 �_�__ For I: 1 mile per hour = 0.447 /s. as Linear interpolation is PLAN KEY PV-1 C0VE PAGE PV-1.1 PV-2 PV-3 ATTACHMENT DETAIL ROOF LAYOUT ELECTRICAL PV-3A ELECTRICAL CONT. PV-12 EQUIPMENT LABELS PILL OF MATERIALS MODULES 21 INVERTERS 21 L-FOOT ATTACHMENT 163" RAILS E PHASE COMBINER BOX EATON 60A FUSIBLE AC DISCONNECT 40 9 1 1 30A FUSES 2 30A BACKFEED BREAKER 1 S, 111 R PRO CUSTOM SOLAR LLC D.8,A. MOMENTUM SOLAR PROFESSIONAL ENGINEERING STATE OF ChM€RON CHRIST€NS€4N CERT19ED SOLAR CONTRACTOR UC€NS€!NUMB€R: CVC57036 MOMENTUM SOLAR 5728 MA30R BLVO, SUITE 307, ORLANDO FL 32819 WHEAT8126 OVER PAGE --------------------------- PER MODULE INSTALLATION MANUAL SECTION A -A 1.50 [38.01 _4 2.76 [70.1] DETAIL C DETAIL D FRONT VIEW &DE VIEW SCALE 1: 6 SCALE I : 6 L-FOOT L-FOOT O-Ea DO NOT SCALE DRAWT FRONT VIEW RAIL W&ZKM Mt R—M M!E W CLICKFIT COMP SHINGLE 'XX xx_xxxx_xx-x----i xn- -j vo 1 m: -i 25 1 A RT-MINI is suitable for mounting any rail system with a conventional L-Foot. Dual bolt design, M8 or 5/16" for L-Foot & 1/4" for EMC ICC ICC ESR 3575 Call Now for more details 858-935-6064 Easy tapping 1W Has soft W—guide uppardmnel Flat lip for pV Ca,,e er=B It harnaf cip.! 'C �aj,H— 1- Engineered to ASTM D 1761 -- -,,, f,� F-w-- " Components RT24)()-MINlBK PAT ENDING AD%. MfNJ base: 20 ea, Sorew: 40 ea. E.ha RT-Sulyll: 10 ea, Optimal item 5 x 60MM Mounting Screw IRr' Oa-S'ii:"` -wN 511T Hex boil washer & nut W 100 -'BW ET. Buty", ;s Poo' Tech's fie.e flpsbi-'g used m 700 0,30 PY systemYne L-sl 24 years 0 Is -hc flsst PV nMlnn syOsn, wil" F#exxjW- ceered tj tine 1CC Metal flashing Retrofit Flex fl)te Flashing Shedding water? 100% Waterproof ICC EsR-3575 ASTM2140 testing W testing 47500 h-) 102,11-4110-10 A EEMM313MEMUM 31/2 (90) jt 2 (5q) I Rafter installation Deck installation P.E. Stamped Lefters a afetife at --.ftarh..s/-ppt momentum SOLAR R.. S $OLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NI 08840 (732) 902-6224 MOMENTUMSOLAR,COM PROFESSIONAL ENGINEERING -5 0 STATE OF 0 RID #VAL CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD, SUITE 307, ORLANDO FL. 32819 BLK-G6+ 340 I INITIAL I DATE: 1/10/2022 1 DESIGNER: HK I REV: I DATE: I DESIGNER: SCALE: 3/32" = V-0" SOLAR INSTALLER NOTES: R1 HAS HORIZONTAL RAFTERS ROOF PANEL COUNT TILT AZIMUTH SHADING LANDSCAPE MAX SPAN PORTRAIT MAX SPAN LANDSCAPE MAX PORTRAIT MAX (ROOF AREA 1/2/3) (ROOF AREA 1/2/3) CANTILEVER CANTILEVER R1 21* 6 201' 1001YO 72/48/48 72 /48 /48 16/10/10 16 /10 /10 momentum R2 15 20* 111* 99% 72/48/48 72 /48 /48 16 /10 /10 16/10/10 SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 (732) 902-6224 MOMENTUMSOLAR.COM PROFESSIONAL WHEAT STONE DR ENGINEERING FRONT OF RESIDENCE DRIVEWAY MSP DISC E Z - CB ELECTRICAL EQUIPMENT g, 0 E OF AL RAFrER SPACINE 24" D.C. (TYP' CLAMPING MAX SPACING IN ZONE 1 72" O.0 AND IN ZONE 2 AND ZONE 3 48" O.0 NOTE: T. -ROOF COVERING MATERIAL IS COMPOSED OF SINGLE LAYER ASPHALT COMPOSITE SHINGLE, 2. REFER TO LAYOUT DETAIL DRAWING PV-3 FOR ALL ROOFTOP DIMENSIONS, TOTAL SQUARE FOOTAGE OF ROOF: 2845 SOFT SQUARE FOOTAGE OF SOLAR ARRAY:441 SOFT SOLAR CONTRACTOR PERCENTAGE OF SOLAR ROOF COVERAGE: 14,23% CAMERON CERTIFIED SOLAR CONTRACTORCHRISTENSEN LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 18" RIDGE SETBACK SHALL BE REQUIRED 5728 MAIOR BLVD. SUITE 307, ORLANDO FL 32819 CUSTOMER INFORMATION SYMBOL LEGEND MONIQUE MALDONADO - MS92907 8126 WHEAT STONE DR ZEPHYRHILLS, FL 33541 EdMAIN SERVICE PANEL CHIMNEY 112- 8132453576 rEM PV INFO SYSI !MEQRMA1LQN- SP SUB -PANEL SKYLIGHT 1 z SYSTEM SIZE (DC): 7.14 KW 21 MODULES: HANWHA Q.PEAK DUO UTILITY METER VENT 0 BLK-G6+ 340 \j ACCESS 21 INVERTERS: ENPHASE IQ7-60-2-US ,OUND (P) DISC AC DISCONNECT 0 PIPE VENT UDC UTILITY DISCONNECT FAN LC LOAD CENTER SATELLITE DISH PR03ECT INFORMATION HNEMA 3R BOX W1 ENVOY-S ME FIRE SETBACKS INITIAL DATE; 1/10/2022 1 DESIGNER:HK REV: DATE: DESIGNER: DESIGNER: MIN X MIN 31 31 GROUND ACCESS CBCOMBINER BOX POINT REV: DATE: S ROOFLAYOUT MODULE PITCH DIRECTION WIND PRESSURE ZONE LINES, REFER TO PV-12 FOR ADDITIONAL INFO PV-2 PV MODULE RATINGS INVERTER RATINGS VOLTAGE DROP CALCULATIONS FORMULA USED PER NEC HANDBOOK 215,2(A)(4) WHERE APPLICABLE MODULE MAKE HANWHA INVERTER MAKE ENPHASE Ukf Q.PEAK DUO WIRE RUN VMP IMP R L (FT) V. % V, WIRE SIZE momentum MODEL BLK-G6+ 340 MODEL IQ7-60-2-US _0LAR MAX POWER 340W MAX OUTPUT POWER 240W BRANCH TO J-BOX 240e00 11 1.98 72.42 3.154 1.31% 12 AWG PRO CUSTOM SOLAR LLC D.B.A, MOMENTUM SOLAR J-BOX TO LOAD 325 HIGH STREET, METUCHEN, NJ 08W OPEN CIRCUIT VOLTAGE 40.66V OPEN DC VOLTAGE 48V 240.00 21 1.24 50.00 1604 1.09% 10 AWG (732) 902-6224 IVIPP VOLTAGE 3194V NOMINAL AC VOLTAGE 240V — CENTER MOMENTUMSOLAILCOM - LOAD CENTER TO AC 240.00 2&25 1.24 3.00 0,195 0.08% 10 AWG PROFESSIONAL SHORT CIRCUIT CURRENT 1032A MAX AC CURRENT 1A DISCONNECT ENGINEERING MPP CURRENT 10.02A AC DISCONNECT TO CEC INVERTER EFFICIENCY 97% INTERCONNECTION 240.00 2615 1.24 10°00 0.651 0.27% 10 AWG NUMBER OF MODULES 21 NUMBER OF INVERTERS 21 NUMBER F MODULES ER M UL NUMBER 1703 L UM 01 1 UL1703 COMPLIANT YES PV B 1703 COMPLIANT YES NEC 705.12(B)(2)(3)(b) 120% RULE SUB PANEL # OF MODULES PER NCH THIS SOLAR PHOTOVOLTAIC SYSTEM COMPLIES WITH THE 2020 INVERTER OUTPUT) MAIN OCPD t- BUS RATING x 1.20 SIZE IZ FLORIDA BREAKER SIZE UPT016 20A FLORIDA BUILDING CODE AND THE 2017 NATIONAL ELECTRICAL CODE (1,25 x 21) + 150:-� 200 x 1,20 FSEC CERTIFICATION STATEMENT. 21 HANWHA Q.PEAK DUO BLK-G6+ 340 340W MODULES PAIRED WITH PER FL. STATUE 377.705 , I, MINA A. MAKAR RE# 86753, CERTIFICATE OF AUTHORIZATION #33404, AN ENGINEER ZI: 21 ENPHASE IQ7-60-2-US MICRO -INVERTERS LICENSED PURSUANT TO CHAPTER 471,CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED 40,z: IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING 'o STATEOF 0 R I'D CODE, FBC 2020 BRANCH CIRCUIT A 11 MICRO -INVERTERS EXISTING SQUARE D 4%, BRANCH CIRCUIT B UTILITY 225A SUB PANEL 240 V 10 MICRO -INVERTERS METER GRID ENPHASE80A + + AC COMBINER SOLAR CIRCUIT F BOX DISCONNECTING MEANS EATON 60A FUSIBLE AC DISCONNECT SOLAR CONTRACTOR 150A CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 8 t MOMENTUM SOLAR 30A 30A [ -_ a 5728 MAJOR BLVD. SUITE 307, ORLANDO FL 32819 ,L-"" - -------- CUSTOMER INFORMATION ROOF 1OA/15A BREAKER j POWER MONIQUE MALDONADO - MS92907 JUNCTION (MANUFACTURER I A 3 USES GROUND 8126 WHEAT STONE DR BOX SUPPLIED FOR ZEPHYRHILLS, FL 33541 TERMINATION CAP 1 2A-B ENVOY) 3 3 EXISTING 200A 8132453576 INSTALLED ON 20A BREAKER (A) METER MAIN PY SYSIM INFORMATION END OF CABLE 20A BREAKER (B) 150A BREAKER SYSTEM SIZE (DC): 7.14 KW 21 MODULES: HANWHA Q.PEAK DUO BLK-G6+ 340 21 INVERTERS: ENPHASE IQ7-60-2-US Wire Tag Conduit Wire Qty Wire Temp. Wire Temp. Conduit Derated Inverter NOC (A) NEC Design Ground Ground Wire GaleWire Type gRating Ampacity JA) Derate Fill Der to Ampacity (A) Qty Correction Current (A) Size Type 1 OPEN AIR 2 12 AWG Trunk Cable 90°C 30 0.96 1 28,80 11 1 1°25 1175 12 AWG Trunk Cable PR03ECT INFOR MATIOar - 2A ill PVC 2 10 AWG THWN-2 75°C 35 0.96 0,8 26.88 11 1 1.25 1175 08 AWG ETHWN-2 INITIAL DATE; 1/10/20 1 22 -- -­ DESIGNER: HK REV: DATE: DESIGNER: T W 2B ill PVC 2 10 AWG THIN-2 75°C 35 0.96 0.8 26.88 10 1 1.25 12.50 08 AWG THAWN-2 REV: DATE: DESIGNER: 3 ill PVC 3 + G 10 AWG THWN-2 75°C 35 0,96 1 3160 21 1 1,25 26°25 08 AWG THWN-2 THREE LINE DIAGRAM NOTE; LE1:7�ER'G' IN WIRE �QTY TAB STANDS FOR�GROU�NDING�CONDU�C-rOR������ PV-3 ELECTRICAL NOTES. 1. ALL CALCULATIONS FOR VOC, VMAX, IMP AND ISC HAVE BEEN BASEDCALCULATED USING THE MANUFACTURED STRING CALCULATOR CARRIED2. THE ENTIRE ARRAY IS BONDED ACCORDING TO (NEC 690.46- 250A20 PARAGRAPH C), THE GROUND IS AWAY FROM THE GROUNDINGBARE COPPER WIRE O I 5. ALL CONDUCTORS ARE SIZED BASED ON NEC 2017 ARTICLE 310 6. ALL EQUIPMENT INSTALLED IS RATED AT 75°C 7, INVERTER NOC (NOMINAL OPEN CURRENT) OBTAINED FROM EQUIPMENT DATASHEET 6. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL LOCAL AND NATIONAL CODE REQUIREMENTS. 9. EACH MODULE MUST BE GROUNDED ACCORDING TO USER INSTRUCTIONS 10. ALL EQUIPMENT SMALL BE LISTED PER NEC 690.4(B) 11. PER NEC 690.13,690.15, PROVIDE A WARNING SIGN AT ALL LOCATIONS WHERE TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION> SIGN SHALL READ *WARNING - ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS - OR 12. PER NEC 705.10, PROVIDE A PERMANENT PLAQUE OR DIRECTORY SHOWING ALL ELECTRIC POWER SOURCES ON THE PREMISES AT SERVICE ENTRANCE. 13. INTERCONNECTION METHOD SHALL COMPLY WITH NEC 705.12 14. AND OPTION FOR A SINGLE CIRCUIT BRANCH TO BE SPLIT INTO TWO SUB -CIRCUIT BRANCHES IS ACCEPTABLE. 15. ALL CONDUCTORS MUST BE COPPER. 16. NEUTRAL AND EQUIPMENT GROUNDING CONDUCTOR BONDED AS PER NEC 250.24(C). 17. EQUIPMENT GROUNDING CONDUCTOR IS CONNECTED TO A GROUNDING ELECTRODE SYSTEM PER 250,54(D). 16. FUSES FOR PV DISCONNECT HAVE AIC RATINGS OF 200KA AC AND 20KA DC. % SUPPLY SIDE CONNECTION SHALL BE MADE USING ILSCO INSULATION PIERCING CONNECTORS (IPC). MAKE, MODEL, AND RATING OF INTERCONNECTION CAN BE SEEN ON TABLE 1 BELOW. 20. METHOD OF INTERCONNECTION CAN BE SEEN IN FIGURE 1. 21. UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 22. WORKING CLEARANCES AROUND THE EXISTING AND NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC ARTICLE 11026. 23. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C)(1) AND ARTICLE 310.E (D). 24. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310,10 (C). 25. TOTAL AREA OF ALL CONDUCTORS, SPLICES, AND TAPS INSTALLED AT ANY CROSS SECTION OF THE WIRING DOES NOT EXCEED 75%4 OF THE CROSS SECTIONAL AREA OF THE SPACE, NEC 312,3(A)(2), 26. SYSTEM IS CONSIDERED AN AC MODULE SYSTEM. NO DC CONDUCTORS ARE PRESENT IN CONDUIT, COMBINER, JUNCTION BOX, DISCONNECT. AND COMPLIES WITH 690.6 - NO DC DISCONNECT AND ASSOCIATED DC LABELING ARE REQUIRED. 27. SYSTEM COMPLIES WITH 690,12 RAPID SHUTDOWN AND ASSOCIATED LABELING AS PER 690.56(C). AC VOLTAGE AND SYSTEM OPERATING CURRENT SHALL BE PROVIDED 690.52. 23. CONDUCTORS IN CONDUIT ARE AC CONDUCTORS BRANCH CIRCUITS AND NOT PV SOURCE CIRCUITS, 690.6. 29. ALL GROUNDING SHALL COMPLY WITH 690.47(A) IN THAT THE AC MODULES WILL COMPLY WITH 250.64. 30. NO TERMINALS SHALL BE ENERGIZED IN THE OPEN POSITION IN THIS AC MODULE SYSTEM 690.13, 690.15, 690.6. 31. WHERE APPLICABLE; INTERCONNECTION SHALL COMPLY WITH 705.12(A) OR 705.12(B) i. 3 w VOLTAGE 1- CON UCTOR CONDU OR 7 RATING RANGE MAINj RANGE TAP _ .. .... * i INSTRUCTIONS FOR LINE TAPS CONTINUALLYFIGURE 1: 1. ADJUST THE CONNECTOR NUT TO SUITABLE LOCATION 2PUT THE BRANCH WIRE INTO THE CAP SHEATH FULLY 1 INSERT THE MAIN WIRE, IF THERE ARE TWO LAYS OF INSULATED LAY IN THE MAIN CABLE, SHOULD STRIP A CERTAIN LENGTH OF THE FIRST INSULATED LAY FROM INSERTED END 4. TURN THE NUT BY HAND, AND FIX THE CONNECTOR IN SUITABLE LOCATION. 5. SCREW THE NUT WITH THE SLEEVE 6. SCREW THE NUT DROPPED THE TOP PART IS CRACKED AND ymomentum 1 =a PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 (732) 902-6224 MOMENTUMSOLAR.COM Eft n;.. � $Q STATE OF to JVALI ; I.I CAMERON CHRISTENSEN CERTIFIED SOLAR COAITRACCOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 MONIQUE MALDOIADO - MS' 8126 WHEAT STONE DR ZEPHYRHILLS, FL 33541 INITIAL I DATE: 1/10/2022 I DESIGNER: H% REV: ! DATE: I DESIGNER; I REV: I DATE: I DESIGNER: I SYSTEM SIZE (DC) LOCATION SYSTEM INFORMATION HAiVWHA Q.PEAK DUO BLK-G10a- 360 ENPHASE IQ7-60-2-US RO FTECH MINI & ECOFASTEN CLI KFIT SYSTEM 2-RAIL 7.2 KW 2& 2 745995,-82.1814 562 0 THIS PV SYSTEM HAS BEEN DESIGNED TO MEET THE MINIMUM DESIGN STANDARDS FLORIDA RESIDENTIAL CODE, 7TH EDITION 2020 FLORIDA BUILDING CODE, 7TH EDITION 2020 FLORIDA FOR BUILDING AND OTHER STRUCTURES OF THE ASCE 7-16, 7TH EDITION 2020 ROOF SHALL HAVE NO MORE THAN TWO LAYERS OF COVERING IN ADDITION TO THE SOLAR EQUIPMENT, STST - 'FNPHASE" MICRO -INVERTERS WITH RAPID SHUTDOWN CONTROL LOCATED ON THE BACK SIDE OF EACH MODULE. THE EXISTING STRUCTURE IS ADEQUATE TO SUPPORT THE NEW LOADS IMPOSED BY THE PHOTOVOLTAIC MODULE SYSTEM INCLUDING UPLIFT & SHEAR.EXISTING RAFTER SIZES & DIMENSIONS CONFORM TO 7TH EDITION 2020 FLORIDA RESIDENTIAL CODE MOUNTING BRACKETS AND HARDWARE MEET OR EXCEED FLORIDA CODE REQUIREMENTS FOR THE DESIGN CRITERIA OF THE TOWN. PER FL. STATUE 377.705 , I, MINA A. MAKAR PE# 86753, CERTIFICATE OF AUTHORIZATION #33404, AN ENGINEER LICENSED PURSUANT TO CHAPTER 471,CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE. FBC 2020 CLIMATIC & GEOGRAPHIC DESIGN CRITERIA TABLE R301.2(1) SPEED (MPH) 140 TOPOGRAPHIC EFFECTS B SPECIAL WIND REGION NO WIND BORNE DEBRIS ZONE 2 SEISMIC DESIGN CATEGORY C CLIMATE ZONE 2A WIND EXPOSURE CATETORY B FBC, RESIDENTIAL 2020 TABLE R301.2.1.3 WIND SPEED CONVERSIONSa V 1t 11101 115 120 130 140 150 160 170 180 190 200 V.d 65 39 93 101 1 tIB 116 124 132 139 147 155 For SIn 1 mile per hour = 0.4 47 /s. a, Linear interpolation is permitted, 360 WATT MODULE (SEE DATASHEET PV-I I COVER PAGE PV-1.1 I ATTACHMENT DETAIL PV-2(2) I SUPERIMPOSED PANELS PV-3.1 I ELECTRICAL CONT. PV-3,2 I EQUIPMENT LABELS MODULES 20 INVERTERS 20 L-FOOT ATTACHMENT W/ RT-ICI N I 40 168" RAILS 9 SKIRTS 8 ENPHASE COMBINER BOX 1 EATON 60A FUSIBLE AC DISCONNECT 1 25A FUSES 2 25A BACKFEED BREAKER I momentumkiDt-111 PRO CUSTOM SOLAR LLC D,B,A, MOMENTUM SOLAR ., 325 HIGH STREET, METUCHEN, NJ 08840 (732)902-6224 w ENGINEERING I ,I CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER:CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 MONIQUE MALDONADO - MS92907 l5 INITIAL DATE: 1/20/2022 DESIGNER:HK REV: BATE: DESIGNER: REV: DATE: '..DESIGNER: PERMODULE INSTALWON MANUAL i i iftam WN; SECTION A -A 019 l.57 1.50 [Zi [38.61 2.76 DETAIL C DETAIL D FROW VIEW SOE VIEW SCALE 1 :6 SCALE 1 :6 L-FOCT L-F= M1 r ---41.57 14001 91FIENNNEWM CLICKFIT COMP SHINGLE RT-MINI is suitable for mounting any rail system with a conventional L-Foot. Dual bolt design, M8 or 5116" for L-Foot & 1/4"' for EMC 1CC ICC ESR 3575 Call Now for more details 858-935-6064 Easy tappft 1W fift soft � 7 0.1de IMSW5116, M H-80A b0flan charoW Engineered to AISTM D 1761 �r-,A-m T----d- �- --, - Tv-d) so, PAT: KNOM MIM baw: 20 e"- SWW: 40 ea, Exft RT-5w: 10 ea- Opu.-4#-. 10-8. RT-B,Ays 35 Ro,d".lbl. S!3: mg u-d 700,00 r�woefa�.' P" zynlem-, �Y Im lw5t, 24 y�w� 12hp air PV Gystm ur Y Fhmbk, "t3SN'1qcwtftd by I.N, IC- vwmft.� R'tnAt Flexible fWft Sheddin water? 100%'Waterproof 3 in 00� Rafter Installation ---------- Deck installation P-E St.,WW UM— —Rabi. at ATTACHMENT DETAIL FOR SHINGLE ROOF momentum SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMEMUM SOLAR 325 HIGH STREET, MUKHEN, NJ 08M (732) 902-6224 MGMFNMMSOLAR.COM A P.17 'OP ...... No PE86753 0 STATE OF XOR10P. CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER; CVC57036 MOMENTUM SOLAR SM KA-JOR BLVD, SUITE 307, ORLANDO FL 32819 DATE: 1/20/2022 1 DESIGNER: HK REVPATE, !!SIGNER. Rli;�.�D�ATe ---]DESIES1 GNEE R: SCALE: 3/32" = V-0'" ROOF PANEL COUNT TILT AZIMUTH SHADING LANDSCAPE MAX SPAN (ROOF AREA 1/2/3) PORTRAIT MAX SPAN (ROOF AREA 1/2/3) LANDSCAPE MAX CANTILEVER PORTRAIT MAX CANTILEVER 10 momentum R2 14 20* ill* 99% 48/32/32 48/32/32 16/10/10 16/10/10 SOLAR WHEATSTONE DR SO LAR INSTALLER COTES, RI, HAS HORIZONTAL PAFTERS CLAMPING MAX SPACING IN ZONE 1 72" O.0 AND IN ZONE 2 AND ZONE 3 48" O.0 NOTE: 1, ROOF COVERING MATERIAL IS COMPOSED OF SINGLE LAYER ASPHALT COMPOSITE SHINGLE. 2. REFER TO LAYOUT DETAIL DRAWING PV-3 FOR ALL ROOFTOP DIMENSIONS. PRO CUSTOM SOLAR LLS D.E.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 (732) 902-6224 MOMENTUMSOLAR,COM PROFESSIONAL ENGINEERING V L EQUIPMENT t % Si4T]i OF X0R1'DV---*' ��!t�11 spa ������� TOTAL SQUARE FOOTAGE OF ROOF: 2845 SOFT SQUARE FOOTAGE OF SOLAR ARRAY:385.89 SQFT PERCENTAGE OF SOLAR ROOF COVERAGE: 13.57% CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 18" RIDGE SETBACK SHALL BE REQUIRED MOMENTUM SOLAR 5728 MAIOR BLVD. SUM 307, ORLANDO F�. 321119 CUSTORER INFORMATION SYMBOL LEGEND MONIQUE MALDONADO - MS92907 4 W#EAT-$,T0 E- ElMAIN SERVICE PANEL CHIMNEY Z EPHYRHILLS, :3541 j 8132453576 El SUB -PANEL SKYLIGHT Pv 'TES 4Nf TI SYSTEM SIZE (DC): 7.2 KW 20 MODULES: HANWHA Q.PEAK DUO 0 UTILITY METER VENT BLK-G10+ 360 ACCESS - 20 INVERTERS: ENPHASE IQ7-60-2-US .OUND ep) AC El AC DISCONNECT PIPE VENT UDC UTILITY DISCONNECT FAN A ElLOAD CENTER SATELLITE DISH PR03ECr II FOftMATION H E/0" NEMA 3R BOX W/ ENVOY-S FIRE SETBACKS INITIAL DATE: 1/20/2022 DESIGNER: HK =L-4 f=L�� DATE REV: DATE: DESIGNER: CB COMBINER BOX MIN TxTGROUND ACCESS POINT =],==fDESIGNER REV' DATE: DESIGNER: ROOF LAYOUT 11 Un MODULE PITCH DIRECTION WIND PRESSURE ZONE LINES. REFER TO PV_2 PV-2.2 FOR ADDITIONAL INFO ,SCALE: s n\A\ RIGHT-OF-WAY R8 EDGE OF WALK Is A- 0.1' NE I LOT 2 BLOCK 2 FORMSOARD SURVEY 0014E 07-29-20 N WALL IS C 27-- NOTE: 2.20 SE WALL TRACT F 1. ROOF VERING MATERIAL IS COMPOSED OF SIGLEYER ASPHALT COMPOIMSCAPE AREA 2, REFER YOUT DETAIL DRAWING PV-3 FOR A O _.,_ 4 IMENSIONS, (PRIVATE) FRONT OF RESIDENCE EG �� WALK IS 0.11 SW & OX NE FORMSOARD FOUNDATION TOP OF FORMS Eiu LEVAIION-91.8X mil PROPOSED ELEVAMis ON-914V Ml- LA LOT 4 BLOCK 2 MAIN SERVICE PANEL CHIMNEY ESUB -PANEL z SKYLIGHT UTILITY MEM z VENT AC DISCONNECT 0 AM VENT tlDC UnLrry DISCONNECT FAN LOAD CENTER SATELLITE DISH NEMA 3R BOX W/ ENVOY-5 FEE FIRE SETBACKS COMBINER Box MIN 3'x3"' ,GIGRD,= ROUND POINT 011, MODULE PITCH DIRECTION WIND PRESSURE ZONE LINES. REFER PV-2,2 FOR ADDITIONAL INFO - Vmomentum SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENrUM SOLAR 325 HIGH STREET, METUCHEN, M 08840 (732) 902-6224 MOMENTUMSOLAR.CDM ENGINEERING -0 OF �"OiVAI- SOLAR CONTRACTOR LICENS. M048ER: CVC57036 MOMENTUN SOLAR 9 HAM BL307, ORLANDO, R- 32819 PERIMPOSITION PLAN PV MODULE RATINGS Q.PEAK DUO MODEL BLK-G10+ 360 i,AX POWER 360W OPEN CIRCUIT VOLTAGE 41.18V MPP VOLTAGE 3431V iHORT CIRCUIT CURRENT 11.04A MPP CURRENT 10.49A NUMBER OF MODULES 20 UL1703 COMPLIANT YES INVERTER RATINGS WIRE R MODEL IQ7-60-2-US BRANCH TO BOX MAX OUTPUT POWER 240W ]-BOX TO LOAD OPEN DC VOLTAGE 48V CENTER NOMINAL AC VOLTAGE 240V LOAD CENTS .TO AC MAX AC CURRENT 1A ET DISCONNt AC DISCONN T TO CEC INVERTER EFFICIENCY 97% INTERCONN ION NUMBER OF INVERTERS 200 1703 COMPLIANT YES VOLTAGE DROP CALCULATIONS FORMULA USED PER NEC HANDBOOK 215.2(A)(4) WHERE APPLICABLE V-P ID R L (FT) V 240°00 14 1.98 92.17 5A10 240.00 20 1.24 50.00 2.480 240.00 25 3.00 0.186 240.00 �1�24 25 1�24 10�00 1� 10�00 0,620 SUB PANEL I # OF MODULES THIS SOLAR PHOTOVOLTAIC SYSTEM COMPLIES WITHM IREAKER SIZE FLORIDA BUILDING CODE AND THE 2017 NATIONAL EL V 20 HANWHA Q.PEAK DUO BLK-G10+ 360 360W MODULES PAIRED WITH 20 ENPHASE IQ7-60-2-US MICRO -INVERTERS momentum 0 % V, 0 V 0 WIRE SIZE - SOLAR 113% 13 12 AWG — PRO CUSTOM SOLAR LLC D.B.A, MOMENTUM SOLAR PRO CUSTOM' 1�03% 10 AWG 10.269%.10 325 HIGH STREET, METUCHEN, NJ 08840 (732) 902-6224 MOMENTUMSOLAR.COM 0.08% 10 AWG PROFESSIONAL ENGINEERING AWG NEC 705,12(B)(2)(3)(b) 120% RULE II 11I (1,25 x INVERTER OUTPUT) + MAIN 0CPD5 BUS RATING x 1,20 (1,25 x 20) 4 150 f, 200 x 11,20 ® X FSEC CERTIFICATION STATEMENT PER FL. STATUE 377.705, 1, MINA A. MA PE# 86753, 7. CERTIFICATE OF AUTHORIZATION #33404, AN ENGINEER LICENSED PURSUANT TO CHAPTER 471,CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING STATE OF 44 CODE. FBC 2020 EXISTING SQUARE D NAU UTILITY 225A SUB PANEL 240 V //I0 METER GRID ENPHASE80A AC COMBINER SOLAR CIRCUIT BOX DISCONNECTING MEANS EATON 60A FUSIBLE AC DISCONNECT m. T 50A 25A 2SA :7— _j ROOF 10A/15:ABREAKERY 'POWER JUNCTION (MANUFACTURER I 25A FUSES TERMINATION CAP 1 SUPPLIED FOR BOX 2A-B ENVOY) 3 3 EXISTING 200A INSTALLED ON 20A BREAKER (A) METER MAIN END OF CABLE 20A BREAKER (B) 150A BREAKER Wire Tag Conduit Wire Qty Wire Wire Type Temp. Wire Temp. Conduit r Derated Inverter e Inverter N 0 NICIC (A) NEC Design Ground Ground Wire Gauge Rating Arnpacity (A) Derate Fill Derate pacify Arnpacity (A) Qty city (A) Qty Correction Current (A) Size Type I OPEN AIR 2 12 AWG Trunk Cable 90°C 30 01�96 1 2&80 14 7C(A) 1 1.25 17.50 12 AWG Trunk Cable 2A 10 AWG THWN-2 75°C 35 0.96 2&88 6 1 1�25 7�50 08 AWG THWN-2 3/4" PVC 4 0�8 — 2B 10 AWG THWN-2 75°C 35 O�96 2&88 14 8 1 1 1.25 17.50 08 AWG THWN-2 3 3/4" PVC 3 + G 10 AWG THWN-2 75'C 35 0.96 1 3160 20 0 0 1 1 1.25 25.00 08 AWG THWN -2 NOTE: LETTER "G" IN WIRE QTY TAB STANDS FOR GROUNDING CONDUCTOR. CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MA3OR BLI/D. SLnTE 307, ORLANDO FL, 32819 CUSTOMER INFOIL MA'rTnfd MONIQUE MALDONADO - MS92907 BLK-GIO+ 360 NkflTIAL DATE: 1/20/2022 DESIGNER: NIX EV: DATE: DESIGNER: EV: DATE: DESIGNER: 1. ALL CALCULATIONS FOR VOC, VMAX, IMP AND ISC HAVE BEEN CALCULATED USING THE MANUFACTURED STRING CALCULATOR BASED ON ASH E 2% HIGH AMC EXTREME MINIMUM TEMPERATURE COEFFICIENTS, 2, THE ENTIRE ARRAY IS BONDED ACCORDING TO (NEC 690A6 - 250A20 PARAGRAPH C), THE GROUND IS CARRIED A14VAY FROM THE GROUNDING LUG USING ##6 BARE COPPER WIRE OR ##8 THWN-2 COPPER WIRE. 3, THIS SYSTEM COMPLIES WITH NEC 2017 5. ALL CONDUCTORS ARE SIZED BASED ON NEC 2017 ARTICLE 310 6. ALL EQUIPMENT INSTALLED IS RATED AT 75*C T INVERTER NOC (NOMINAL OPEN CURRENT) OBTAINED FROM EQUIPMENT DATASHEET 8. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL LOCAL AND NATIONAL CODE REQUIREMENTS. 9. EACH MODULE MUST BE GROUNDED ACCORDING TO USER INSTRUCTIONS 10. ALL EQUIPMENT SHALL BE LISTED PER NEC 690.4(B) 11, PER NEC 690.13, 690.15, PROVIDE A WARNING SIGN AT ALL LOCATIONS WHERE TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION} SIGN SHALL READ *WARNING - ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS - OR EQUIVALENT, 12, PER NEC 705,10, PROVIDE A PERMANENT PLAQUE OR DIRECTORY SHOWING ALL ELECTRIC POWER SOURCES ON THE PREMISES AT SERVICE ENTRANCE. 13, INTERCONNECTION METHOD SHALL COMPLY WITH NEC 705.12 14. AND OPTION FOR A SINGLE CIRCUIT BRANCH TO BE SPLIT INTO TWO SUB -CIRCUIT BRANCHES IS ACCEPTABLE. 15. ALL CONDUCTORS MUST BE COPPER, 16. NEUTRAL AND EQUIPMENT GROUNDING CONDUCTOR BONDED AS PER NEC 250.24(C). 17. EQUIPMENT GROUNDING CONDUCTOR IS CONNECTED TO A GROUNDING ELECTRODE SYSTEM PER 250.54(D). 18, FUSES FOR PV DISCONNECT HAVE AIC RATINGS OF 200KA AC AND 20KA CSC, 19. SUPPLY SIDE CONNECTION SHALL BE MADE USING ILSCO INSULATION PIERCING CONNECTORS (IPC). MAKE, MODEL, AND RATING OF INTERCONNECTION CAN BE SEEN ON TABLE 1 BELOW. 20. METHOD OF INTERCONNECTION CAN BE SEEN IN FIGURE 1. 21. UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 22. WORKING CLEARANCES AROUND THE EXISTING AND NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC ARTICLE 110.26. 23, CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C)(1) AND ARTICLE 310.8 (D). 24, CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C), 25, TOTAL AREA OF ALL CONDUCTORS, SPLICES, AND TAPS INSTALLED AT ANY CROSS SECTION OF THE WIRING DOES NOT EXCEED 75% OF THE CROSS SECTIONAL AREA OF THE SPACE. NEC 312.8(A)(2). 26, SYSTEM IS CONSIDERED AN AC MODULE SYSTEM, NO DC CONDUCTORS ARE PRESENT IN CONDUIT, COMBINER, JUNCTION BOX, DISCONNECT. AND COMPLIES WITH 690.E - NO DC DISCONNECT AND ASSOCIATED DC LABELING ARE REQUIRED. 27. SYSTEM COMPLIES WITH 690.12 RAPID SHUTDOWN AND ASSOCIATED LABELING AS PER 690.56(C). AC VOLTAGE AND SYSTEM OPERATING CURRENT SHALL BE PROVIDED 690.52, 28. CONDUCTORS IN CONDUIT ARE AC CONDUCTORS BRANCH CIRCUITS AND NOT PV SOURCE CIRCUITS. 690.6. 29. ALL GROUNDING SHALL COMPLY WITH 690.47(A) IN THAT THE AC MODULES WILL COMPLY WITH 250.64. 30. NO TERMINALS SHALL BE ENERGIZED IN THE OPEN POSITION IN THIS AC MODULE SYSTEM 690.13, 690.15, 690,6, 31. WHERE APPLICABLE: INTERCONNECTION SHALL COMPLY WITH 705,12(A) OR 705A2(B) 32, ALL WARNING SIGN(S) ORLABEL(S) SHALL COMPLY WITH 2O17 NEC ARTICLE 110.21(B), LABEL WARNINGS SHALL ADEQUATELY WARN OF THE HAZARD. LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT, AND LABELS REQUIRED SHALL BE SUITABLE FOR THE ENVIRONMENT, 33. PV POWER CIRCUIT LABELS SHALL APPEAR ON EVERY SECTION OF THE WIRING SYSTEM THAT IS SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS. TABLE 1: VOLTAGE CONDUCTOR CONDUCTOR MAKE MODEL RATING RANGE MAIN RANGE TAP IL SCO IPC 4006 600 V 4/0-4 AWG 6-14 AWG ILSCO IPC 4020 600 V 4/0-2 AWG 2J0-6 AWG INSTRUCTIONS FOR LINE TAPS CRACKEDFIGURE 1: 1, ADJUST THE CONNECTOR NUT TO SUITABLE LOCATION 2. PUT THE BRANCH WIRE INTO THE CAP SHEATH FULLY 3. INSERT THE MAIN WIRE, IF THERE ARE TWO LAYS OF INSULATED LAY IN THE MAIN CABLE, SHOULD STRIP A CERTAIN LENGTH OF THE FIRST INSULATED LAY FROM INSERTED END 4. TURN THE NUT BY HAND, AND FIX THE CONNECTOR IN SUITABLE LOCATION. 5, SCREW THE NUT WITH THE SLEEVE 6, SCREW THE NUT CONTINUALLY UNTIL THE TOP PART IS DROPPED DOWN 'momentum PRO CUSTOM SOLAR LLC D.S,A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, N) 08840 (732) 902-6224 MOMENTUMSOLAR..COM CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307. ORLANDO FL, 32819 Mw SYSTEM SIZE (DC): 7.2 KW 20 MODULES: HANWHA Q.PEAK DUO BLK-G10+ 360 20 INVERTERS: ENPHASE IQ7-60-2-US INITIAL DATE: 1/20/2022 DESIGNER: HK REV: DATE: DESIGNER: L T I� LCONT. -Daniel W. Dunzl*k Architect LEER -AP 370 Burnt Hill Rd. Skillman NJ. 08558 908-872-3664 StudioGdesign@comcast.net January ll,2022 Re: Proposed Photovoltaic Solar Panel Installation Monique Maldonado 8126 WHEAT STONE DR ZEPHYRHILLS, FL 33541 Dear Plan Reviewer: Certification., I have reviewed the engineering testing reports for the racking and attachments to be used on this project and I certify that the products are capable of supporting the code required loads and are suitable for this installation when installed in strict compliance with the manufacturers printed instructions. Regarding the solar panel array installation on the above referenced project please note that an inspection was performed by a representative of the Architect/Engineer of Record, and analysis of the existing structure was conducted. There is adequate structural capacity for the installation of the array with the following recommendations: 1. The array will be installed on the existing roof. The roof training is constructed of 2"x4" wood trusses @24" o.c. spanning 18'10" with a top chord length of 20'6" with intermediate supports at 1/3rd points, making the effective longest span equals T4" with 1/2" plywood sheathing. The new array (See Site map by contractor) will add 2.63 Lb. SE overall to the roof. The existing structure is sufficient to support the new loads associated with the additional weight & wind resistance. No additional structural support is required for the roof structure. 2. The attachment system shall be secured to the roof and shall be in strict compliance with manufacturers printed instructions. The attachment system shall be UL 1703 approved tested. Provide 6 mil, vapor barrier between dissimilar metals. Provide water tight gasket and sealant at all penetrations. Attachments shall follow panel rows as specified by the system manufacturer's installation manual. The panel angle shall match the roof slope. Reference summary table below: E22LLEL- Shingle Fastener Max Spacing (in.) Attachment SLS �M "ROOFTECH"O `RT MINI 11" & 'EcolFasten" Click Fit8 Attachemem Systems Wind Zone I Wind Zone 2 Wind Zone 3 Fastener Info: min. 5/16" x 4" long stainless -steel lags with a min, 72 48 48 embedment of 3" into the rafters 3. Solar Modules shall be UL- 1703 rated. Refer to manufacturers specifications sheets, 4. Positive drainage of the system shall be so as not to void the existing roof warranty. 5. All aspects of the installation shall comply with the Florida Administrative Code, 2020 Florida Building Code - Residential Seventh Edition, ASCE-7-16, 2020 Florida Building Code — Energy Conservation, Seventh Edition, 2017 National Electric Code, All Local Governing County and Municipal Ordinances adopted by reference or enacted by law. All components used meet the criteria of the Florida Solar Energy Center. 6. Please refer to the attached structural calculations. If you have any questions relating to this matter, please contact me at your earliest convenience. Thank you. OF C Daniel W. Dunzik, RA. LEED-AP FL, Lic. No. AR98795 A ip % Daniel W. Dunzl*k Architect LEED-AP 370 Burnt Hill Rd. Skillman NJ. 08558 908-872-3664 StudioGdesign(a_)comeast.net January 11, 2022 Gravitv Load Calculation Criteria Structural Design Loads per ASCE 7-16 Dead Loads = 10 psf + 2.6 psf (new solar panels) = 12.6 psf Roof Live Load = 20 psf Ground Snow Load/Live Load = 0 psf Wind Load Calculation Criteria Wind Loads per ASCE 7-16, Equation 29.4-7 Using an effective wind area of 10 SF, external pressure coefficient from Figure 30.3-A-1 Zone I = -36,5 psf Roof Slope = 21 degrees Roof Mean Height = 15 ft Zone 2 = -47A psf Basic Wind Speed = 140 mph Zone 3 = -54.7 psf Exposure = B Per section 2.4.1, ASD combo = D + 0.6W: Zone I = 2.6 psf + 0.6(-36.5 psf) = - 19.3 psf Zone 2 = 2.6 psf + 0.6(-47.4 psf) = -25.8 psf Zone 3 = 2.6 psf + 0.6(-54.7 psf) = -30.2 psf Check Attachment to Wood Truss Use 5/16 dia, Lag screw w/ 3 " embedment into 2 in. wide roof rafter Lag Screw Spacing: Lag Screw Tributary Area: Zone I = 72" o.c. max Zone I = (72" o.c. max)/12 / 144 = 36 SF Zone 2 = 48" o.c. max Zone 2 = (48" o.c. max)12 / 144 = 16 SF Zone 3 = 48" o.c. max Zone 3 = (48" o.c. max)/2 / 144 = 16 SF Lag Screw Forces: W = 266lb/in (Table 12.2A, 2015 NDS) Zone I = 19.3 psf x 36 SF = 695 lb < W', OK Cd = 1.6 (Table 2.3.2, 2015 NDS) Zone 2 = 25.8 psf x 16 SF = 413 lb < W', OK Ct = I (Table 2.3.3, 2015 NDS) Zone 3 = 30.2 psf x 16 SF = 483 lb < W', OK W'= W x embed x Cd x Ct W'= 266 lb/in x 3 in, xl.6 x I = 1276.8 lb BREAKING THE 20% EFRCiENCY BARRIER Q,ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.6%. INNOVA4,9fE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low -light and temperature behavior. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology, Anti PID Technology', Hot -Spot Protect and Traceable Quality Tra.QTm. EXTREME WEATHER RATING High-tech aluminum alloy frame, certified for 11,1171 high snow (6000 Pa) and wind loads (4000 Pa). A RELiABLE INVESTMENT Inclusive 25-year product warranty and 25-year linear performance warranty'. S111"ATE OF THE ART MODIUILE TECHNOLOGY Q,ANTUM DUO combines cutting edge cell separation C= and innovative 12-busbar design with Q,ANTUM Technology, APT test conditions according to IEC/TS 62804-1:2015, method 6 (-1500V, 168h) See data sheet on rear for further information. THE IDEAL SOLUTION FOR, Rooftop arrays on residential buildings Engineered in Germany OCELLS '2.a"fi8a0-) a 41,2'(1294 mm) &x prouMin0 peNn,a a 0.18° (4.5 mm) C3 b _0 t 4>R'(1209 mm) 9xMountin9 able (DETAIL A) 0.83" {i6mm) DETAIL A 0.96'rer5 mm) T0.33'(8.5mm; 0. 6 15.0' (3�6rnm7 gme 38.6"(9is I90.8" a030 mm) No ELECTRICAL CH TEWgip.-ICS POWER CLASS 365 370 375 380 385 Pun, [W] 365 370 375 380 386 [A] 10.40 10 44 10,47 10.50 10.53 . .a. Voc V] 44.93 44,97 4501 45.04 45-08 _... . ......... vno [A] 9.87 9.92 ., ...,. _,,, , 9.98 _,., ... _.__,,,... 10,04 .,. 10,10 V.11 IV) 36.99 37.28 37.57 37,85 3813 >_19.5 'a19.8 a20.1 �20.3 pmpp [W] 273.3 277.1 280.8 284.6 288.3 c A] 8.38 8 8.41 8.43 8.46 8.48 m Voc M .. [V] _ 42.37 42.41 42.44 42.48 42,51 vrn A] 776 7.81 7.86 7.91 7.96 V.11 [V] 35.23 35.48 35,72 35.96 36.20 lmeasurement tolerances 'n . ±3 /; I,_ VCC±S%at STC: 10001N/m', 25±2°C, AM 15 according to [EC 60904-3. 2800 W/m2, NMQT, spectrum AM 1.5 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE At least 98 % of nominal power during first year. Thereafter max. 0.5 % degradation per year. At least 93.5 % of nominal power up to 10 years. At least 86 % of nominal power up to 25 years All data within measurement toleranc- es. Full warranties in accordance with the warranty terms of the Q CELLS sales organisation of your respective country. Typical module performance under low irradiance conditions in comparison to STC conditions (25 °C,1000 W/m2) TEMPERATURE COEFFICIENTS K] +0 04 (9 [%/ K] -0.27 _ Y (%!K] -035 a ' ,"-tr,z,,. >t2_.,. NMQT °F] 109±5.4(431-3°e) PROPERTIES FOR SYSTEM DESiGN ", . .. [V] 1000 (IEC)/1000 (UL) " Class II .. ... ... _. .. . , [A CSC] 20 TYPE 2 fibs/fit'] 84(4000Pa)/55(2660Pa} 40°Fupto+185°F [lb s/ft2] 111 25(6000P11a 8411 (40010F11 a} " (-40°Cupto+85'C) 3 See Installation Manual t "g 7"� & I r:S „;r e" t AND'TRANSPORT �", � i E., "'� rd L` '`�, 1 -'QUALIFICATIONS .?�%€�, a ?, �" 3 ... PACKAGING �[za7 ,��R� 'S.a�xa �'`A,.. � -.�' ,�� a UL 61730, CE- rrp:;art.;15a' EC 61215:2016, - 4.._E C} 0 cO NC IEC 617302016, uS. Patent No. 9,893.215 Tovnn«mwoa " .r 74.4In 42.51r1 47.6in 1458lbs 28 24 32 (solarpens) C ilifldus C E 1890mm 1080mm 1208mm 661kg pallets pallets modules ul er,3o iD ;,;"zzo n Note: Installation instructions must be followed, See the installation and operating manual or contact our technical service department for further Information on approved Installation and use of this product. Hanwhe 0 CELLS America Inc. 400 Spectrum Center Drive, Suite 1400, Irvine" CA 92618. USA I T EL +1949 748 59 961 EMAIL inquiry@us.a-cells.com 1 WEB www.q-cells.us Sheet Enphase Microinverters 1 � �� h r'ii a s e r# The high-powered smart grid -ready and t drematieslly simplify the installation process while " achieving the highest system efficiency, generationsPart of the Enphm IQ System, the IQ 7 and IQ Envoy", Enphase IQ Benery', and the Enphase EnlightenrO monitoring and analysis software, IQ Series Microinverters extend the reliability standards set forth by previous Y enabling Enphase to provide an industry -leading warranty of up to 25 years, Lightweight and simple Faster Installation with Improved, lighter two -wire cabling Built-in rapid shutdown compliant (NEC 2014 & 2017) testing Optimized for high powered 60-cell and 72-cell* modules More than a million hours of UL listed Class 11 double -insulated enclosure frequency ride -through requirements Remotely updates to respond to changing grid requirements Configurable for grid profiles Meets CA Rule 21 (UL 1741 -SA) To learn more about Enphase offerings, visit enphase.com ENS A S E N' H A S 0 2018 Enphase EneMy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc. 2018-0524 n P a s e 0.< b (X-1Q-AM1-240-,3)1 LISTED T,0 learn, rno�e abou', Em',,hase of ferungs, visit enphase,corn Enphase IQ Combiner 3" vv1'-h'-'-n" asc into ncile, a nri n e i-V 1 c I a nis,,, a w d 1c", iaie-ovi-eci s:,­ cti a r'� ,l 'r loir to, s e r e, Smart Includes IQ Envoy for communication and control Flexible networking supports Wi-Fi, Ethernet, or cellular Optional AC receptacle available for PLC bridge Provides production metering and optional consumption monitoring I= Reduced size from previous combiner Centered mounting brackets support single stud mounting Supports back and side conduit entry Up to four 2-pole branch circuits for 240 VAC plug-in breakers (not included) 80 A total Pit or storage branch circuits UMM Durable NRTL-certified NEMA type 3R enclosure Five-year warranty UL listed S E N P H A �. E Enph,ase Q Connbiner 3 NMOU NUMBER' 0 1 �—hww V VXx` A wx"M" I xQ Fnnnc 0 F "M . Dmqm CWMA bow& WT We7wea Munn gne p"' �w'nolta�t!'orl ODT"nap ccnsumplmr monwonrig 1+b 211"', ACCESSORIES awc QEPLACEPAENT PARTS hMhme NQhQ !A�nw' CALL MOCKNIAGAG, !?.am 'jma ron, pag Ow Ua "amny " "c' fyi(,canwv\-V� da;,a �,ilan byt "it) I', ni" WELL TOOD0001 !x; 5 Vem ova p4m; ingromVp1wo Ovyww).'—I' Ono u's' '�A""acy% "t"id the 0",-, V�fc:!-' TU VAIDUM M! 45 bwoo. TE N4 N vew oam nkri wNN y; !hwe is a"mWe wIn"o am m me mwAnw ,away Owmamtorp Wymr Aphl nyr vampt lans'nnnrs mabY "tow Mwe ')'I MR.' 3R2 1~� .N240'. �-3�'2. ,,,J y,,!t(-'wt hre,,�kers SK Em 2 Q�"' GunUn OrKMAMA 1 MY l3k I alon RP2 T 9RKISAO''4�' Cimm wnkp! 2 pok, 1 at; Unr BR2 1 �- 6RK 20AIPOV' Crcwt crevinn d mn AVA Lam BRON, 1 pl 1�0-,. ,y- 1wi xx %*:Yp Awm"" MMMMW V 9MV Way cW10 1, K) comnrw, A ("Uumc fm f FA A. M, KA FNVATHN,, 1'.LECTRCAL SPECH-'lCAIFIONS COMMUMS wo, '11yor VAC 00 P' OV, 40 W you ATOV twon, yip, iynwy mvt ncltidec� q 1 ll' 804 of IONNIVO WA W" Q 5 x A n, T a "r Yq 1 , 14 '7, 6 61"' A TV 153 Y cry Y QM rmnplho hla"KW Kg, 10 5 Q' A31 sq, 2i A N K A on"er w=4 A W d AMA"We cwMwtm�� 6G A rowsm, Wwwry =y 4 0 1 0 ANY"c"n cmmmwo, Wrwe , D C'UNO q.560 (1!,-" " "', d y!"l Onme, IDUmn; nmVa' )MOPQ UUMODUK!" = or CLUN/liA"Lio-J3 � "-,G" ba,,,,cio 1A LAI) Jot Hmo;"c' COMPLMNCE WAN',",Sy), AN'o'oz',:!2 W) AMNW=Q ME n. .1 bw, WS1 n 2 N; so n' To Amn mom OWi,,,t nionase, oflenngs,, wst'i enphase,con- V 2MO EnMaw EmMy XKpin wwwd M VMmuUm nwd.,in 11-F, d,,)a.imcnt ',,rc r(-,qsmmd bvJ0r,cspmiv-,owneF ENPHASE 4L.e.ss Aluminum 4more Efficient Design )o6cidonal Mounting Options 410e.tal, EPDM, km Asphalt Roofs 99 Ic ESR 3575 I RT Serrated Hex Flange Bolt/Nut: 5/16-18 x 1 " R,T-MINI 11 is suitable for all systems with a conventional L-Foot. 1/41�1 x 1 " Carriage Bolt EMT 8 Screw: 40 ea, Extra RT-Butyl 4 ea. — Optional Items: Deck Installation Rafter Installation RT-Bu1y| is Roof Tmuh^m flexible flashing used in one million residential PVsystems for the last 27years, Kisthe first PVmounting eys\om with Flexible Flashing certified by the |CC, Engineered to withstand wind apaodmupto18Omph and ground onmwup0o8OPat, TAS 100Aon metal and asphalt roof, P.E. StampadLeKemavmilablnatwvmw.mof-teoh.us/support --- Offset Rafter Installation 4 Flexible Flashing 100% Waterproof � FLORIDA BUILDING CODE COMPLIANCE FLORIDA BUILDING CODE 2020 REQUIREMENTS Questions often arise in the solar industry as to the requirements for installing solar mounting systems in Dade and Broward counties and throughout the rest of the Florida, Outlined below are the four requirements to comply with the 2020 Florida Building Code. The first three requirements are necessary for solar racking systems, while the fourth is specific to solar roof attachments. The fifth item, Florida -specific testing, is optional for installation. 1 - UL CERTIFICATIONS Racking UL 2703 (Supplied by EcoFasten) 2 - MODULE LOAD RATING 3 - RACKING STRUCTURAL CAPACITY Florida PE stamped system capacity and span tables that meet site conditions and roof zones for the project (Supplied by EcoFasten) 4 - ROOF ATTACHMENTS o Structural Capacity certification letters that meets or exceeds site conditions (Supplied by EcoFasten) Waterproofing/Flashing per NRCA & FRSA/TRI (Florida) guidelines (Supplied by EcoFasten, when applicable) 5 - OPTIONAL FLORIDA SPECIFIC TESTING OR CERTIFICATIONS Florida Product Approval Miami Dade NOA Water Seal Testing: TAS100(A) (required for HVHZ Florida Product Approval or Miami Dade NOA) EcoFasten, For Installers, By Instatters, ECOFASTEN ROOF ATTACHMENTS — FLORIDA COMPLIANT Ecol'asten offers two roof attachments that meet the specifications for installation in the State of Florida, which are GF-10 and QB-1 as shown below, GF-1 GF-11 is a versatile solution for use on composition shingle roofs. The 8" x 12" flashing installs with a single fastener and when combined with an Ecol'asten compression bracket, a watertight seal is created, maintaining the integrity of the roof. Available GF-10 SKUs: ® 3012010 - GF-1 FLASHING GLV BLK 8x1211 0 3012011-GF-1 FLASHING GLVMLL8Xl2yp 0 2012022 - CF UNIV L-FOOT MILL 3" CIF-11 Structural Capacity Documentation for Permit Packets ClickFitL-Foot,Copact,R��rt 02'.29.2021 GF-1 Installation Manual Florida 08.11,2021 v2.0 EcoFasten I Page 3 ECOFASTEN ROOF ATTACHMENTS — FLORIDA COMPLIANT QB--1 Q13-1 uses a super strong base that can be used on composition shingle, tile, shake, slate, metal shingle, and low slope rooftops. This is a rail -based solution is ideal for new residential construction projects. The base can be installed prior to the roofing material, allowing for the roof to be shingled or tiled around the posts. Available QB-1 SKUs: 0 3017010 - Q13-1 BASE AL 0 3017011 - QB-1 POST AL IVILL 4.5" 0 3017012 - QB-1 POST AL MLL 6,5" 0 3017013 - QB-1 FLASHING AL IVILL 12X12" 0 3017014 - QB-1 FLASHING AL IVILL 18XI8" 0 3017015 - QB-1 EPDM COLLAR BLK 1,25" QB-1 Structural Capacity Documentation for Permit Packets -_l State oLFlorida Gerd Licaton Letter 07,29.2021 QB-1 Installation Manual 04,09.2021 v1,0 ECOFASTEN RACKING SYSTEM — FLORIDA COMPLIANT kAH,"l"", F �Tl� ClickFitO is one of the fastest installing rail -based systems in the industry. With its click -in rail assembly, the rails can be connected to any of EcoFasten's composition shingle, tile, and metal roof mounts in seconds without the need for fasteners or tools. The ClickFit system is made of robust, anti -corrosive materials, such as aluminum and cold formed coated steel, to ensure the strength, corrosion resistance, and longevity. Available ClickFit Rail SKUs: 0 2012021 - CF STD RAIL MILL AL 14FT 0 2012025 - CF STD RAIL AL MILL 171.5" ClickFit UL 2703 Certification for Permit Packets ClickFitUL27036pproved lnstallation Manual Version 0706.2021 v2,5 ClickFit U rove Addendum 06.07,2021 v1,1 ClickFit Module Load Rating/Span Tables for Permit Packets OickFit Master Letter Certi�ication 04,15.2021 j ClickFit Waterproofing for Permit Packets � ClickFit UL 441 Rain Report 03,IZ2021 EcaFasten For Instatters, By Installers, EcoFasten I Page 5 GQI(UT SHEETS WATERPROOFING PER NRCA GUIDELINES Designed and Certified for Compliance with the Florida Building Code & C Sg9 ^`~ \naeQ% By Instatters, Em9snIPage 6 QB-1 CUT SHEETS 3017010 QB-1 BASE AL STRUCTURAL CERTIFICATION Designed and Certified for Compliance with the Florida Building Code & ASCE/SEI-7 EcoRisten, For InstaLlers, By Instalters, EcoFasten I Page 7 QB-1 CUT SHEETS STRUCTURAL CERTIFICATION Designed and Certified for Compliance with the Florida Building Code & ASCE/SEI-7 EcaFasten. For Installers, By Instatters, EcoFasten I Page 8 QB-1 CUT SHEETS 3017013 QB-1 FLASHING AL MLL 12X12" 3017014 QB-1 FLASHING AL MLL 18X18" WATERPROOFING PER CIRCA GUIDELINES Designed and Certified for Compliance with the Florida Building Code & ASCE/SEI-7 \> EcoFasten For Instatters By Instatters, EcoFasten I Page 9 CLICKFIT CUT SHEETS - STRUCTURAL CERTIFICATION Designed and Certified for Compliance with the Florida Building Code & ASCE/SEI-7 UL 2703 Conforms to UL 2703 Mechanical & Bonding requirements, See Ecol'asten ClickFit Installation Manual for full ratings. 4 0 RoFasten For Instatters, By Installers EcoFasten I Page 10 0 PERMITTING PACKETS Listed below is the documentation you will need to provide to your AM for permitting approval. Click on the link to download file, LIL 2703 CERTIFICATIONS: ClickFit UL 27 3 Approved Installation Manual Version 07.06,2021 v2.5 ClickFitUL2703ALoRrqved,AddendumO6.07.2021vl.1 STRUCTURAL CERTIFICATIONS: OickFit L-Foot Cq2qCttZAqport 07.29,2021 ClickFit Master Letter (jertIffication P4.15.2021 GF-1 Installation Manual Florida 08.11.2021 v2.0 0 a Certification Lqtter 07,29,2021 ,6-11 State o Florid w ClickFiWL441 Rain Rf2tart Q3.17.2021 INSTALLATION MANUALS: GF-1 Installation Manual Florida 08.11,2021 v2.0 OPTIONAL CUT SHEETS: EcoFasten. For Installers, By Instatters EcoFasten I Page 11 CONTACT ECOFASTEN 4141 W Van Buren Street, Suite 2, Phoenix, AZ 85009 877.8593947 1 ecofastensolar.com Ec a Fa ste n, For installers, By Instatters C PER MODULE INSTALLATION MANUAC- SECTION A -A FRONT VIEW RAIL 1,57 [40.0] EW11111U11,\`11'111 structural ENGTNEERS 4141 W Van Buren St, Ste 2 Phoenix, AZ 85009 Attn.: Eco Fasten Solar - Engineering Department Re: Report #2O19-11325HGlB.01—EcmFosten-OickFit System for Gable and Hip Roofs Subject: Engineering Certification for the State of Florida PZSE, Inc. — Structural Engineers has provided engineering and span tables for the EcoFasten - ClickFit System, as presented PZSE Report # 2019-11325HG,05.01, "Engineering Certification for the EcoFasten - ClickFit System for Gable and Hip Roofs" . All information, data, and analysis therein are based on, and comply with, the following building codes and typical Building Codes: 1, 202OFlorida Building Code, byFlorida Building Commission 2. AGCE/SE|7-16,Minimum Design Loads for Buildings and Other Structures, by American Society ofCivil Engineers 3. 2O1DInternational Building Code, byInternational Code Council, Inc. 4. 201QInternational Residential Code, byInternational Code Council, Inc. 5. AC428, Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV)Panels, November 1,2Ol2by|[C-ES 6 Aluminum Design Manual 2O15, byThe Aluminum Association, Inc. 7. ANSI/AWC NDS-2018, National Design Specification for Wood Construction, by the American Wood Council Design Criteria: Risk Category || SeismicDesignCmtegory=A-E Exposure Category =B,C&kD DIGITALLY SIGNED Basic Wind Sd(ultimate) ASCE716 90 mph to 180 mph %1111 0.73522 This letter certifies that the loading criteria and design basis for the EcoFasten - ClickFit System Span Tables are in compliance with the above codes, If you have any questions on the abovedo not hesitate to call. N TH I IS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED13 A 11, Prepared by: PZSE, Inc. —Structural Engineers I PRINTED C,0PIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED Roseville, CA I AND SEALED AND THE SHA-1 AUT HENTICATION CODE MUST BE VERIFIED ON ANY ELECTRONIC COPIES, 14783tone Point Drive, Suite l9U. Roseville, C/\9566) � 916961.3960 916961,3965 vv °vwxw,pzse.conn OMMERIM EcoFasten Solar LLC 4141 W Van Buren S%,I Phoenix, AZ 85009 TEL: (877) 859-3947 F1111111102=91a7mm Re: Report # 2019-11325HG5,01 Engineering Certification for the Ecol'asten Solar LLC ClickFit - Rail System for Gable and Hip Roof, PZSE, Inc. - Structural Engineers have reviewed EcoFasten Solar LLC ClickFit System. All information, data, and analysis contained within the EcoFasten Solar LLC ClickFit System Rail span tables are based on and comply with the following codes: 1. Minimum Design Loads for Buildings and Other Structures, ASCE/SEI 7-16 2, 2018 International Building Code, by the International Code Council, Inc. 3. 2018 International Residential Code, by the International Code Council, Inc. 4. AC428, Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV) Panels, November 1, 2012, by ICC-ES 5, Aluminum Design Manual 2015, by The Aluminum Association, Inc. IN!% !III !I R III IN ITINI MEMMMEMMMMM Design Criteria: Ground Snow Load ® 0 - 60 (psf) Basic Wind Speed 90 - 180 (mph) Roof Mean Height m 0 - 30 (ft) Enclosed and Partially Enclosed Gable and Hip Roof Pitch = 0 0 - 60® (degrees) Exposure Category = B, C & D Attachment Devices: The evaluation of the ClickFit System considers the ClickFit L-Foot. Rail: The evaluation of the ClickFit System Rail p/n 2012021 (450124, REV X03), made with an aluminum alloy, 6000 series, with a minimum yield strength of 35 ksi. Cantilever: Maximum cantilever length is L/3, where "L" is the span noted in the Span Tables, provided at least 1 module length between maximum cantilevers, 1478 Stone Point Drive, Suite 190, Roseville, CA 95661 916.9613960 9l&961.3965 www,pzse.com structural ENGINEERS Clearance: 2" to 10" clear from the top of the roof to the top of the PV panel. Tolerance(s): 1.0" tolerance for any specified dimension in this report is allowed for installation. PV Module Size: 60-Cell PV Panel max dimension is 68.5 72-Cell PV Panel max dimension is 80.41 Installation Orientation: Landscape (L) ® PV Panel long dimension is parallel to the ridge/eave line of the roof, and the PV panel is mounted on the short side, Portrait (P) - PV Panel short dimension is parallel to the ridge/eave line of the roof, and the PV panel is mounted on the long side. =�l 1478 Stone Point Drive, Suite 190, Roseville, CA 95661 916.961,3960 916.961,3965 www,pzse.com am Roof Zones — Enclosed and Partially Enclosed Gable and Hip Roofs, 70 < 0:5 60 0: The Edge Zone, "a," shall be determined using figure 30.3-213 to figure 30.3-2D of ASCE 7-16, for Gable roofs. The Edge Zone, "a," shall be determined using figure 30.3-2E to figure 30.3-21 of ASCE 7-16, for Hip roofs. Interior Zone I span shall be the minimum of 1 and 1' (See ClickFit System Rail Span Chart). Corner Zone 3 spans shall be the shortest of 3e and 3r (See ClickFit System Rail Span Chart). See Figure 2. EDGE ZONE OR 3'.0" MIN J CORNER ZONE �� — X SEE DETAIL FQA MOUNT LOCATION INTERIOR ZONE,, LU RIDGE . ..... 02- ZO NE 0 SEE DETAIL FOR 0 MOUNT LOCATION I INTERIOR ZONE 7) GABLE r. HIP '2 FDGF ZONE 0 !9 HATCHED AREA tNDICATES INTERIOR ZONE I in DISTANCE azOAxI(LHO)OR 1,3) CORNER ZONE §EE ME IVIUM OF 3%0" DETAIL FOR MOUNT LOCATION "ALL EDGE OF ROOF Figure 2: Roof Zones, Gable and Hip Roofs, 71 < 0!5 451 Panel with Support Mounts in Multiple Roof Zones: Edge and Corner Zone spacings (Zone 2 & 3, respectively) apply only to mounts located in those Zones, not to all the mounts supporting the module. Notes: 1) Tables are determined for Rail and L-foot only and does not include roof capacity check. 2) Risk Category 11 per ASCE 7-16. 3) Topographic factor, kzt is 1,0, 4) Average parapet height is 0.0 ft. 5) Wind speeds are I -RFD values. 6) Attachment spacing(s) apply to a seismic design category E or less, Panel Array Edge® Panels exposed at array edge shall use figure 29.4®7 of ASCE 7-16 to determine "Eli" and "d2" to apply "Array Edge" spans that apply to an array layout. See figure 3. 1478 Stone Point Drive, Suite 190, Roseville, CA 95661 91&9613960 916.961,3965 www.pzse.com WWI M"1111111im"s structural ENGINEERS NON EXPOSED ARRAY d, EXPOSED ARRAY EDGE 1,510 TYP ROW OF SOLA EDGE OF ADJACENT SOLAR ARRAY OR BUILDING EDGE Figure 3: Array Edge '"W", 01C IIWQ�11%'• , M.— "M , - - 5, - . . - , - . required by the authority having jurisdiction. In all cases, these tables should be used under the directiolno .0. design professional with sufficient structural engineering knowledge and experience to be able t7o: 0 Evaluate whether these tables apply to the project, and This letter certifies that the EcoFasten Solar LLC ClickFit Railed System, when installed according to the limitations of this letter and the attached span tables, complies with the above codes and loading criteria. This certification excludes evaluation of the building structure to support the loads imposed on the building by the array; including, but not limited to strength and deflection of structural framing members, fastening and/or strength of roofing materials, and/or the effects of snow accumulation on the roof. Structures will require additional knowledge of the building and are outside the scope of the certification of this racking system. 111111111111ir !!I I I r I ��!1!1 11pil;I11:111111:111: iiiiiiii; 111111zfl�' I Prepared by: PZSE, Inc. —Structural Engineers Roseville 1478 Stone Point Drive, Suite 190, Roseville, CA 95661 916.961.3960 916,961,3965 www.pzse,com Iff"I"F111"ImIl", V11,1101111,11"i Table of Contents Item........................................ ........................................................................................................... Page # Span Tables for Flush -Mount CickFit System on 0-30 Foot Roof, 60-Cell Modules - Portrait .... .................. .......... 6 Span Tables for Flush -Mount CickFit System on 0-30 Foot Roof with 72-Cell Modules - Portrait 14 Span Tables for Flush -Mount CickFit System on 0-30 Foot Roof with 60-Cell & 72-Cell Modules - Landscape .... _ 22 Appendix A:Ecofastem(]ickFhCut Sheets, .... —...... ......... ----------------.~.—....... ... —........... ... �BO )478Stone Point Drive, Suite 19I Roseville, CA 95661 5of31 I 10of31 13 of 31 Romm 16of31 F1►�it�i, NKMI FBI 23 of 31 29of31 Company ; Feb 19, 2021 Designer 06:43 AM Job dumber: Checked Sy; Section Properties: Sectiort't 40 241 X 3). XF Section Information: Material Type = General Shape Type = Arbitrary Number of Shapes 1 Basic properties; Total Width - = 1,575 _ in Total Height = 1.575 in Centroid, Xo = 0.000 in Centroid, Yo - 0.756 in X-Bar (Right) - 0.767 in X-Bar (Left) - 0.767 in Y-Bar (Top) - 0.7€33 in ' Y-Bar (Bot) - _ = 0.786 l-- in Max Thick = 1.575 —_ �. in v i tt ,I € qivalent properties„ Area, Ax = 0.373 inA2 Inertia, Ixx = 0.151 inA4 i Inertia, lyy 0,100 inA4 - Inertia, Ixy = -0.000 in"4 Sx (Top) = 0.191 inA3 Sx (Sot) m 0.191 inA3 Sy (Left) = 0.126 inA3 —_ ^ Section Diagram Sy (Right) = 0,126 in"3 rx 0.635 in ry = 0.516 in Plastic Zx -^ = 0.222 inA3 Plastic 2y = 0,160 inA3 Torsional J = <do Galc.> As-xx Def --�� - 1.000 As-yy Chef �m = 1.000 As-xx Stress 1.000 As-yy Stress _ = 1.000 C:\RISA\SectionRrojectl page 2 mmm