Loading...
HomeMy WebLinkAbout22-3594U-1 fy-0- f 7 ' 11-yrfffR� 5335 Eighth Street Zephyrhills, FIL 33542 Phone: (813) 780-0020 Fax: (813) 780-0021 ELCMISC-003 L— Issue Date: 02/ REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent remspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. 11 1111111 1111111110 111111111 111 ;'11 11 !1111 111 1 11,11111:11 1:11 ilIF I!1111 I Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. PERMIT EXIJ a z PE r11T OFFICIEV 5 IN 6 M*NTHS WITHOUT APPROVED INSPECTION 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department gy Dells Received �Ph.n. Contact for �PemnhI 7AfV- 05� 16114119 t it a I Owner's Name L_�Je ) WN Owner Phone Number M NA� Owner Phone Number Owner's Address F C!�4CCJ4'S �f � � I Fee Simple Titleholder Address JOB ADDRESS LOT # SUBDIVISION PARCEL ID00 -3 (O.TAIND FROMPROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR FJ ADD/ALT SIGN DEMOLISH INSTALL E:] REPAIR PROPOSED USE SFR COMM OTHER TYPE OF CONSTRUCTION BLOCK 0 FRAME STEEL DESCRIPTION OF WORK BUILDING SIZE SO FOOTAGE HEIGHT a4.WLkk1LILkX1L tk�kxkkx�gAtILIL kx =BUILDING Q 4 ),,,VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL =PLUMBING =MECHANICAL AMP SERVICE PROGRESS ENERGY = W.R.E.C. VALUATION OF MECHANICAL INSTALLATION =GAS ROOFING [::] SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY E SIGNATURE REGISTERED FEE CURREN / N�� Address License # ELECTRICIAN COMPANY SIGNATU RE REGISTERED 5&�:IEr FEE Address L License # M col REGISTERED FEE CURREN PLUMBER COMPANY SIGNATURE Address License #E===== MECHANICAL COMPANY SIGNATURE REGISTERED E�L;�F FEE �C.RR CURREN �Y Y_LN J Address License # OTHER COMPANY SIGNATURE REGISTERED YIN FEE CURREN Y/N Address License # RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & I clumpster, Site Work Permit for subdivisionellargo projects COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. -PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely, Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (AIC upgrades over $7500) Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage) Driveways -Not over Counter if on public roadways..needs ROW ca 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be ofted for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division --Licensing Section at 727-847- 8009, Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not property licensed and is not entitled to permitting privileges in Pasco County, TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy' or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500,00 or more, I certify that 1, the applicant, have been provided with a copy of the 'Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner, I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment, Southwest Florida Water Management District -Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers -Seawalls, Docks, Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency -Asbestos abatement. Federal Aviation Authority -Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone W" unless expressly permitted. If the fill material is to be used in Flood Zone "K, it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone 'K in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit poor to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, after, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. to me or hasmoVe produced as identification. 11 Name of Notary typed, printed or stamped FF IVETTE E. CABREJA Willon # HH 102795 May 11, 2025 8=WftTMyF*kWM=4W7019 a M. Who is/ rsonally known to me or haslhbve produced as identification. id ritification. Notary Public commill M_1_1/ - Name of Notary typed, printed or stamped INSTR# Z 14 OR BK -1 IJD&+Z) PG AUV I Page 1 of 1 02/07/2022 08:43 AM Rcpt: 2413253 Rec: 10.00 DS: 0.00 IT: 0,00 Nikki Alvarez-Sowles, Esq., Pasco County Clerk & Comptroller � -IL1 6b Ve-f-T Permit Number Par cal ID Number 03-26-217,0220-100F001-0040 NOTICEOF COMMENCEMENT State of Florida County of THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Section 713 13 of the Florida Statutes, the following information is provided in this NOTICE OFCOMMENCEMENT, 1. Description of property (legal description): SILVER OAKS VILLNGE - PHASE TWO PB 50 PG 029 BLOCK F LOT 4 a) Street Ube) Address 2,Gimeral description of improvements: _ Roof Mounted PV Sy stern 3,Own*r Information or Lessee info Ian If the Lassee contracted for the Improvernent. a) Name and address John Pertel 37450 Picketts Mill Ave Zephyrhills FL 33542 b) Name and address of fee simple titleholder (if different than Owner fisted above) c) Interest in property 4.Contractor Inforniation a) Name and address S Lin run Installation Services Inc 5208 Tampa West Blvd Tamjj FL 33634 b) Telephone No.: Fax No. (optional) 5.6urety (if applicable, a copy of the payment bond is attached) a) Name and address. b) Telephone No.: c) Amount of Bond: 6. Lender a) Name and address, b) Telephone No.: 7, Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 71313 (1) (a) 7_, Florida StaMes: a) Name and address: b) Telephone No.: Fax No.: (optional) S. a) In addition to himself or herself, Owner designates of to reotfive a copy of the Lienor's Notice as provided in Section 713.13 (1) (b), Florida Statutes. b) Phone Number of Person or entity designated by Ownec 9. Expiration date of notice of commencement (the expiration date may not be before the completion o� construction and final payment ttl the contractor, but Y411 be I vex from the date of reoordina unless a different date is specifkid)o 3/28/22 20 --- SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE # DESCRIPTION • SYSTEM SIZE: 11 220W DC, 7920W AC « ALL WORK SHALL COMPLY WITH 2020 FBC (7th Ed.) Amendments SOLAR MODULES PV-1.0 COVER SHEET • MODULES: (33) HANWHA Q-CELLS: Q.PEAK DUO to 2018 IRC/IBC/IEBC, MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS ED SERVICE ENTRANCE BLK-G8+ 340 ANINSTRUCTIONS, D INSTALLATION PV-2.0 SITE PLAN INVERTERS: (33) ENPHASE ENERGY: IQ7-60-2-US - PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017, RACKING: SNAPNRACK RLU- RL UNIVERSAL, SPEEDSEAL MP MAIN PANEL PV-3.0 LAYOUT TRACK ON COMP, SEE DETAIL SNR-DC-00436 - ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017. PV-4.0 ELECTRICAL SNR MOUNT - PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY SP SUB -PANEL SNR MOUNT & SKIRT PV-5,0 SIGNAGE GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35, • MODULES CONFORM TO AND ARE LISTED UNDER UL 1701 LC PV LOAD CENTER CHIMNEY • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741, 1B SUNRUN METER ATTIC VENT • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. FLUSH ATTIC VENT • SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE 1, OR TYPE 11 Piv1 DEDICATED PV METER MODULES. ARE CLASS A FIRE RATED, PVC PIPE VENT - RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL INV INVERTER(S) METAL PIPE VENT CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). T-VENT F—AC-] * CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). AC DISCONNECT(S) SATELLITE DISH ® ARRAY DO CONDUCTORS ARE SIZED FOR DERATED CURRENT, FDC DC DO DISCONNECT(S) FIRE SETBACKS * 10A AMPS MODULE SHORT CIRCUIT CURRENT. * 16.25 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (a) & 690.8 (b)]. CB IQ COMBINER BOX L HARDSCAPE INTERIOR EQUIPMENT PL— PROPERTY LINE L SHOWN AS DASHED _J SCALE:NTS A AMPERE sunrun AC ALTERNATING CURRENT AFC! ARC FAULT CIRCUIT INTERRUPTER ENGINEER ADDRESS 225 BUSH ST, SUITE 1400 AZIM AZIMUTH SAN FRANCISCO, CA 94104 P 949-383-099L VICINITY MAP COMP COMPOSITION DO DIRECT CURRENT EC13007964 u a (E) EXISTING 5208 7 AMPA'VlBLVD. TAMPA, FL 33634 ESS ENERGY STORAGE SYSTEM FAX 0PHONEO EXT EXTERIOR 5 INT INTERIOR CUSTOMER RESIDENCE: MAG MAGNETIC JOHN PERTEL 7- MSP MAIN SERVICE PANEL 37450 PICKETTS MILL AVE, (N) NEW ZEPHYRHILLS, FL, 33542 E W, NTS NOT TO SCALE 3U5-D AC Oc ON CENTER TEL. (813) 701-8381 Ave, Zion hs PRE-FAB PRE -FABRICATED APN: 03-26-21-0220-OOFOO-0040 ,No 84923 PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC PROJECT NUMBER: STATE OF ",411 RSD RAPID SHUTDOWN DEVICE 802R-45OPERT 0 tOW'Op"' N, TL TYP TRANSFORMERLESS DESIGNER: (415) 580-6920 ex3 A, /0 NAL V TYPICAL VOLTS ABID JAMAL W WATTS SHEET Signed on: 1/2712022 REV NAME DATE COMMENTS M COVER SHEET Fo� Structural Only V: Al 1/26/2022 Z PAGE PV-1.0 GO ARRAY TRUE MAG PV AREA SITE PLAN - SCALE = 3132" = V-0" PITCH AZIM AZIM (SQFT) AR-01 26' 161 ° 190' 463.5 AR-02 26' 91, 100, 96.6 AR-03 26° 91, 100* 77,3 (E) RESIDENCE E r-- O ARRAY AR-03-- (E) FENCE j —x I PL PL PL PL PL f L PL PL CL f k ar 4 E +sY < ENGINEER ADDRESS sunrun nrun .... 9 225 BUSH ST, SUITE 1400 SAN FR NC€SC`O CA 04104 - 7—..._.. .,..,...P 34y 3E3-0993 F i3 G r I i EC13007964 .�...................._..�....�_..�...�_.�..� -- '-_"--._ __..._..,_., �.. .__._ ,}- 520TAMPAW BLD TAMPA,, PC. 33634 i 0 ( NT1 4E a._�..-.—__._.�.__....._.._.._..— ' CUSTOMER RESIDENCE.- pL PL P� PL PL PL PL JOHN PERTEL 37450 RIC ETTS MILL AVE, t l (I 3I Ill f i j ZEPHYRHILLS, FL, 33542 E� j ------- r� MP ; (N) ARRAY AR-02 ,E,4 �AC (i) ARRAY AR-01 (E) GATE TEL_ (813) 701-8381 ,' CB SE APRs:03-26-21-0220-OOFOO-0040 No 84923 PROJECT NUMBER: — 602R-450PERT STATE OF DESIGNER: (415) 580-6920 ex3 -- ARID JAMAL � SI-i1=1=T signed om 1/27/2022 SITE PLAN REV: Al 1/26/2022 NOTE, MICRO -INVERTERS INSTALLED UNDER EACH MODULE PAGE -ZO ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Max Type' OC Detail Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD: 3 PSF Span Spacing OC Spacing Overhang OC Spacing Overhang SNOW LOAD: 0 PSF — — WIND SPEED: AR-01 COMP SHINGLE - RLU 1-Story 2X6 PRE -FABRICATED TRUSSES 6'- 6" 24" RL UNIVERSAL, SPEEDSEAL TRACK 6'- 0" 2'- 4" 4'- 0" 2'- 0" STACKED 138 MPH 3-SEC GUST, COMP, SEE DETAIL SNR-DC -00436ON S.S.LAG SCREWS: AR-02 COMP SHINGLE - RLU 1-Story 2X6 PRE -FABRICATED TRUSSES 6'- 6" 24" RL UNIVERSAL, SPEEDSEAL TRACK ON COMP, SEE 6 - 0" 2'- 4;' 4'- 0" 2'- O'� STACKED 5/16": 2,5" MIN EMBEDMENT DETAIL SNR-DC-00436 STRUCTURAL NOTES: * INSTALLERS SHALL NOTIFY AR-03 COMP SHINGLE - RLU 1-Story 2X6 PRE -FABRICATED TRUSSES 6'- 6" 24" RL UNIVERSAL SPEEDSEAL TRACK ON COMP, SEE 6'- 0" 2'- 4" 4'- 0" 2'- 0" STACKED ENGINEER OF ANY POTENTIAL DETAIL SNR-DC-00436 STRUCTURAL ISSUES DI - AR-01 - SCALE: 1/8"= 1 -0" D2 - AR-02 - SCALE: 1/8" a 1 -0" OBSERVED PRIOR TO AZIM: 181' AZINI: 91' PROCEEDING W/ PITCH: 26* PITCH: 26' INSTALLATION. IF ARRAY (EXCLUDING SKIRT) -- 1 V6" 8'3" IS WITHIN 12" BOUNDARY F6" 6' REGION OF ANY ROOF PLANE __ EDGES (EXCEPT VALLEYS), 6'TYP, 6'TYPj 6' THEN ATTACHMENTS NEED TO BE ADDED AND OVERHAN( REDUCED WITHIN THE 12" BOUNDARY REGION ONLY AS FOLLOWS: ALLOWABLE ATTACHMENT SPACING INDICATED ON 20'-7" cz IDSTO BE REDUCED BY 50% ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE 12'- ATTACHMENT SPACING INDICATED ON PLANS 2'-3" sunrun ENGINEER ADDRESS 225 BUSH ST. SUITE 1400 SAN FRANCISCO, CA 04104 Pi 949-383-0993 EC 13007964 D3a AR-03 - SCALE: 1/8"m V-0" AZINI: 91' 6" 1'-4" 52S8 TAMPAWBLVD, TAMPA. FL 33634 PHO14E 0 PITCH: 26° FAX 0 4'TYP. CUSTOMER RESIDENCE: JOHN PERTEL 37450 RICKETTS MILL AVE, ZEPHYRHILLS, FL, 33542 ,j4EW 13'-8" '\CENS�� < TEL. (813) 701-8381 Z: No 84923 APN: 03-26-21-0220-OOF00-0040 PROJECT NUMBER: r a;'Q� ZZ 802R-45OPERT STATE OF A' tORIV­(� "A DESIGNER: (415) 580-6920 ex3 At, ARID JAMAL SHEET Signed on: 1/27�2022 LAYOUT REV: Al 1/26/2022 SEE SITE PLAN FOR NORTH ARROW PAGE PV-3.0 120/240 VAC SINGLE PHASE SERVICE METER #-. DUKE ENERGY 3598749 UTILITY GRID (N) 125A ENPHASE IQ SUPPLY SIDE TAP AC COMBINER BOX WITH INTEGRATED 1 (33) HANWHA Q-CELLS: OA ENVOY BREAKER 3CX-IQ-AM1-240-3C Q.PEAK DUO BLK-G8+ 340 MODULES AND MICRO -INVERTER PAIRS KA (N) LOCBLE EXISTING 200A BLADE TYPE (33) ENPHASE ENERGY: MAIN BREAKER FUSED AC IQ7-60-2-US DISCONNECT JUNCTION BOX EQUIVALENT k'3 R 0) (1) BRANCH OF (11) EXISTING MICRO -INVERTERS [A] 200A (1) BRANCH OF (11) <-- MAIN MICRO -INVERTERS [B] FACILITY PANEL 50A FUSES 1BRANCH OF 11) () ( LOADS ------ MICRO -INVERTERS [C] �r� GROUFAC4UTY ND SQUARED 20A BREAKER [A] NOTE: TOTAL PV BACKFEED = 50A D222NRB 20A BREAKER [B] USED FOR INTERCONNECTION 3R, 60A 20A BREAKER [C] CALCULATIONS 120/240VAC CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 0 NONE NONE NONE (1) 6 AWG BARE COPPER 1 NONE (2) 12 AWG PER ENPHASE Q NONE (1) 6 AWG BARE COPPER RA CABLE BNCH 2 3/4" EMT OR EQUIV. (6) 10 AWG THH N/THWN-2 NONE (1) 8 AWG THHN/THWN-2_ 3 3/4" EMT OR EQUIV. (2) 8 AWG THHN/THWN-2 (1) 10 AWG THHNITHWN-2 (1) 8 AWG THHN/THWN-2 14 3/4" EMT OR EQUIV, (2) 6 AWG THHN/THWN-2 (1) 8 AWG THHNITHWN-2 NONE MODULE CHARACTERISTICS HANWHA Q-CELLS: Q.PEAK DUO BLK-G8+ 340: 340 W c3 A V1 OPEN CIRCUIT VOLTAGE: 40.7 V MAX POWER VOLTAGE: 34.34 V SHORT CIRCUIT CURRENT: 10.4 A No.!'I STATE OF o P, EXPIRES: 2/28/2023 TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION 2017: 690.13(B) i LABEL LOCATION: ADJACENT TO PV BREAKER (IF APPLICABLE). PER CODE(S): CEC 2019: 705.12(B)(2)(3)(b), NEC 2017: 705.12(B)(2)(3)(b) LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF APPLICABLE). PER CODE(S): CEC 2019: 705.12(B)(2)(3)(c), NEC 2017: 705.12(B)(2)(3)(c) ! SOURCES: i Sul u!N i uu`Y "f!! GRIDAND PV I II SOLAR ELECTRIC SYSTEM LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL, PER CODE(S): CEC 2019: 705.12(B)(3), NEC 2017: 705.12(B)(3) a LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): CEC 2019: 690.54, NEC 2017: 690.54 LABEL LOCATION: INSTALLED WITHIN S OF RAPID SHUT DOWN SWITCH PER CODE(S): CEC 2019: 690.56(C)(3), NEC 2017: 690.56(C)(3), IFC 2012: 605A 1 A, IFC 201 & 1204.5.3, CFC 2019: 1204.5.3 a TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSMON TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S): CEC 2019: 690,56(C)(1)(a), NEC 2017: 690.56(C)(1)(a) NOTES AND SPECIFICATIONS: • SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 ARTICLE 110,21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ, * SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. • LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. • LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. . SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. • DO NOT COVER EXISTING MANUFACTURER LABELS. �ti�1lSiiilllit!!! No. 85111 � x °x STATE OF i s�ONALit� EXPIRES; 2/28/2023 0 s111*1 I Astra v.1.62 in aul n January 27, 2022 WS /,�/ CAT I Subject : Structural Certification for Proposed Residential Solar Installation. VA E W V James Matthew 111alsh, State of Florida, Professional Engineer, License No. 84923 Job Number: 802R-45OPERT Rev Al Client: John Partial "No 84923 This item has been digitally signed and sealed by James Matthew Walsh, PE on 1/27/2022 Address: 37450 Picketts Mill Ave, Zephyrhills, FL, 33542 rising a Digital Signature. Printed copies of this 4, STATE OF 4t _ document are not considered signed and sealed 0 %f ram and the SHA authentic, non code must be verified on electronic copies, Attn: To Whom It May Concern o, /ONAL '001filWO Signed on: 1127/2022 A field observation of the existing structure at the address indicated above was performed by a site survey team from Sunrun. Structural evaluation of the loading was based on the site observations and the design criteria listed below, Design Criteria: - 2020 FBC (7th Ed.) Amendments to 2018 IRC/IBC/IEBC, 7-16 ASCE & 2018 NDS Basic Wind Speed V = 138 mph, Exposure 6 Ground Snow Load = 0 psf Based on this evaluation, I certify that the alteration to the existing structure by the installation of the PV system meets the requirements of the applicable existing and/or new building code provisions referenced above. Additionally, I certify that the PV module assembly including all attachments supporting it have been reviewed to be in accordance with the manufacturer's specifications, 225 Bush St. Suite 1400 San Francisco, CA 94104 . . ....... Q.ANTUM TECHNOLOG W. LOW LEVELlIZED COST OF ELECTRICITY Higher yield per surface area, lower BOS costs, higher power classes, and an efficiency rate of up to 19,8 iNNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low -light and temperature behavior. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID and Anti PID Technology', Hot -Spot Protect and Traceable Quality Tra.QT11. EXTREME WEATHER RNI ING High-tech aluminum alloy frame, certified for high snow (5400 Pa) and wind loads (4000 Pa), A RELIABLE INVESTMENT Inclusive 25-year product warranty and 25-year linear performance warranty2. STAWE OF THE ART MODULE TECHNOLOGY %t Q.ANTUM DUO combines cutting edge cell separation and innovative 12-busbar design with Q,ANTUM Technology, APT test conditions according to IEC/TS 62804-1:2015, method B (-1500Y 168h) See data sheet on rear for further information THE IDEAL SOLUTION FOR: 69 Rooftop arrays on residential buildings Engineered in Germany OCELLS MECHANICAL SPECIFICATION 68,5 x 40.6 x 1.26in (including frame) (1740 x 1030 x 32 mm) S&V (1740 m) 15V (as(, A" 43,9 ps (19,9 kg) 38'", (9.0 i (3.2mm) thermally pre -stressed glass 7- with anti reflection technology 4 0-rd1W _Int� a t- is 5 G-ral, Inl� pl� (4,5 Rama Composite film aa.62.halmmi Black anodized aluminum 6 x 20 monocrystalline Q.ANTUM solar half cells ..... . . ... 2.09-3.98 x 1,26-2.36 x 0,69-0.71in (53-101 x 32-60 x 15-18 mm), Protection class I P67, with bypass diodes ( e)-) 4mma Solar cable; e45.3 in (1150 ml I-) c45.3in (1150 mi Stilubli MC4; IP68 4 hi-ang acs (DETAIL A) DETAILA ELECTRICAL CHARACTERISTICS POWER CLASS 335 340 346 350 . ...... .... .... . .. ... ..... .. . .. .... . ..... . . . . . . .... . . PmPP 335 340 345 350 Isc [A] 10.34 10.40 1045 10.51 Voc IV] 40,44 40.70 40.95 41,21 IMPP [A] 9,85 9.90 9.96 1001 ..... .... . .. ... Vera [V] 34.01 3434 34.65 34.97 . . .. .... . . .. ...... . ..... n . ... .. ......... . .. ?18: 7 ?19,0 ?19 3 ? 19.5 PMPP [W] 250,9 254.6 2584 2621 Isc [A! 8.33 8.38 8A2 8,47 Voc IV] 38.13 38.38 38: 62 38.86 In, p [A] p 7.75 7.79 7.84 7.88 Von` IV] 32.36 32.67 .. ...... ... 32.97 3&27 . .... .......... 'Measurement tolerances PAP ±3 %; lac, Vd, 5 % at STC: 1000 W/m2, 25 ± 2 °C, AM 1.5 according ....... ... ..... ­­ .. . .. ... to IEC 60904-3 2800VAM2, NMOT, spectrum AM 1.5 .. ......... .. ... . 0 CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE At least 98% of nominal powercuring --T - - - - - r - - - - - - - - - - --- - - - - -11 0, first year. Thereafter max. 0.54% K111 c", "E 0'' degradation per year, At least 931% ---- Z of nominal power up to 10 years. At least 85% of nominal power upto ( ..... .. ... 8o ---------------------------- neasurement tolerant - Full warranties in accordance with so20. "a seD soo Woo the warranty terms of the 0 CELLS n sales organization of your respective3 lo ai 2o 48 country. Typical module performance under low irradiance conditions In comparison' to STC conditions (25'C, 1000W/m2) TEMPERATURE COEFFICIENTS a [%/Kl +004 V [%/K] -027 . ... ...... . .. .......... . .. ............. y [%/K] -0.35 7,o .z,.,,,„ NMOT ['F] 109 5.4 (43 3'C) PROPERTIES FOR SYSTEM DESIGN �!C, V 1000 (IEC)/1000 (UL) Class 11 [A DC I 20 TYPE 2 (lbs/ft'l ....... . ...... 75 (360OPa)/55 (2667Pa) -40*F up to +185'F (lbs/ft'l 118 (5400 Pa) / 84 (4000 Pa) (-40'C up to + See Installation Manual (')UALIFICA'ION S AND CERTIFICATES U L 61730, CE-impla,ut, VDE Quality Tested, 00* JEC 61215:2016, Of hts. PACKAGING AND TRANSPORT INFORMATION 153, P153-A, 0-1-0 0 n 0 A 1-0- 701in 42.5in 47.6in 148511cs 28 26 32 U.S. Patent No, 9,893,215 (solar tolls)C C,nfffl� Us L 1780mm 1080mm 1208mm 674kg pellets pallets modules UL 61730 10-11 "1 U2 277 71,5in 45.3in 48,Oin 1505ps 28 24 32 1815mm 1150mm 1220mm 683kg pallets pallets modules Note: Installation instructions must be followed. Seethe installation and operating manual or contact our' technical service department for further information on approved installation and use of this product. Q CELLS supplies solar modules in two different stacking methods, depending on the location of manufacture (moddes are packed horizontally or vertically). You 081 find more detailed information in the docurnew "Packaging and Transport Information', available from Q CELLS, Hanwhe 0 CELLS America Inc. 400 Spectrum Center Drive, Suite 1400, Irvine, CA 92618, USA I TEL +1949 748 59 96 1 EMAIL inquiry@us.q-cells.com 15EB www.q-cells.us E"In P1.11h ak S e 7 a n d Micro"i"nverters N To learn more about Enphase offerings, visit enphase.com The high-powered smart grid -ready Eriphase IQ 7 MicroTm and Enphase IQ 7+ MiCrOTM dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy'm, Enphase IQ BatteryT11 , and the Enphase Enlighten T11 monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, enabling Enphase to provide an industry -leading warranty of up to 25 years. Lightweight and simple Faster installation with improved, Ughter two -wire cabling Built-in rapid shtutdown compliant (NEC 2014 & 2017) Productive and Reliable Optimized for high powered 60-cell/ 120 half -cell and 72- cell/144 haff-cell* modules More than a million hours of testing Class 11 double -insulated enclosure Smart Grid Ready Complies with advanced grid support, voltage and frequency ride -through requirements Rernotely Updates to respond to changing grid requirements Configurable for varying grid profiles Meets CA Rule 21 (UL 1741. SA) � The. !Q 7+ Micro is requiredw support 72-cell/144 half -cell modules. Yoh ENPHASE. Enphase IQ 7 and IQ 7+ Microinverters, INPUT DATA (DC) IQ7-60-2-US IQ71PLUS-72-2-11JS Commonly used module pairings' 235W-350W+ 235W-440W+ Module compatibility 60-ceII, 120 half,cell PV modules 60-cell, 120 half -cell and 72- only cell/144 half -cell PV modules Maximum input DC voltage 48V 60V Peak power tracking voltage 27 V - 37 V 27 V - 45 V Operating range 16 V - 48 V 16V-60V Min/Max start voltage 22 V / 48 V 22V/Coca V Max DC short circuit current (module Isc) 16A 15A Overvoltage class DC port 11 11 DC port backfeed current 0 A 0 A PV array configuration I x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) IQ 7 Microinverter IQ 7+ Microinverter pear cralt'sut power Ca it. .. .....27«a VA Maximum continuous output power 240 VA 290 VA, Nominal (L Q soltage/range2 240 V / 208V/ 240 V / 208 A 211-264 V 183-229 V 211-264 V 183-229 V Maximurn continuous output current 1,0 A (240 V) 115 A (208 V) 1,21 A (240 V) 1,39 A (208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47 - 68 Hz 47 - 68 Hz AC short circuit fault current over 3 cycles 5,8 Arms 5,8 Arms Maximurn units per 20 A (L-L.) branch circult3 16 (240 VAC) 13 (208 VAC) 13 (240 VAC) 11 1208 VAC) Overvoltage class AC port III III AC port bar kfeed current 18 my, 18 rns, Power factor setting 1.0 1:0 Power, factor (adjustable) 0,85 leading 0,85 lagging 0,85 leading-, 0,85 lagging EFFICIENCY @240 V @208 V @240 V @208 A Peak efficiency 976 % 97,6 A 975% 973 % CEC weighted efficiency 970% 97,0% 97,0% 9 7, 0 of MECHANICAL ES A Arnivie'nt temperature range -410 1 C t I o 6 1 50C Relative hurnidity range 4% to 100% (condensing) Connectortype MC 4 (or Ampherug H4 1JTX with additional Q-DCC-5 adapter) Dimensions (HxWxD) 212 mm x 175 mm x 30,2 trim (withoul bracket) Weight 1,08 kg C-2,38 lbs) Cooling Natural convection No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class H double -insulated, corrosion resistant polymeric enclOSLIre Environmental calegory UV exposure rating NEMA Type 61 outdoor FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten rnonhoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load -break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1, UI_1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B. CAN/CSA-C22,2 NO, 1071-01 This product is UL Listed as PV Rapid Shot Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22,1­2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when instaired according rnanufactmer's instructions, 1. No enforced DC/AC ratio, See the compatibility calculator at 2. Nominal voltage range can be extended beyond norqnal if required by the utility. 3. Units may vary- Refer to local requirements to define the number of microinverters per branch in yaw area. To learn more about Enphase offerings, visit enphase.com ENPHASE, 202C Erphaso Ene.r, � tc y Mright's reaNved rnphas,% the Eiphasc logo, E_nphasc IQ 7, Enphas�, IQ _17+, E-chas e IQ Baty, r Erphase Enlignte.r. EnDhaSe 101 'MOY, and -other,radd ma,ks or serv,ce names are to a trademarks of Enp"ase Erergy Inc Data am,,cct to cha!-ge, 2020 08 12 SNAFNRACK RL UNIVERSAL SPEEDSEAL TRACK COMPOSITION ROOF MOUNTING 0 5(16' S.S. L EMBED 0 5f16'LAG SCREW 2-1/2'INTO THE ROOF STRUCTURAL MEMBER / RAFTER FOR TORQUE SPECIFICATIONS SEE INSTALLATION MANUAL 0 5116° S.S. LAG SCREW 2-1/2" MINIMUM EMBEDMENT WASHER SPEEDTRACK—\ T, s O'� STATE OF ROOF RAFTER (TYR) ROOF ATTACHMENTS SHALL BE EMBEDDED INTO ROOF RAFTERS OR OTHER STRUCTURAL MEMBERS ONE REVISION: _jyjjRLj9 _VgWpgLAIL -99P Z.__wa=L -NUMIM— DE AL TRACK A m m DETAIL A SPEEDSEALTRACK SHOULD BE INSTALLED PARALLEL TO RAFTER ROOFING MATERIAL PILOT HOLE CENTER OF COURSE ROOF .EANIHING, UNDERLAYMENT, AN D ROOFING MATERIAL (TYP.) -SPEEDSEALTRACK COMPLETED INSTALLATION SECTION VIEW This item has bs� Macirmcally SlIpTed and sealed by jasm sraft, RE m 12/22M uskv a Digital 2-112'Mild. EMBED N Signature. Panted copies d INTO RAFTER OR STRUCTURAL MEMBER fts document are notconsidered sued and sued COMPLETED INSTAZ M, code musk be verftd on slectmic copies. ScanrunSaalh LLC SCALE, PART NUMSER� DESCRIPTION: DESIGNER: D.RYAN - SNR-DC-00436 RL UNMRSAL, ATTACHMENT DErArL, MOUNT DRAFTER: 8,PETER90N _ NTS SPEEDSEAL TRACK ON COMP APPROVED BY: WARBUCKLE 7171202. 1 sunrun ENGMSR ADDRESS 225 MJV 5T. WM IM EC13007954 DESIGNER: t4l*j mw-l>uZv ex DOMINGO VIUARUEL SHEET MOUNTING DETAIL REV: A 1211812020 PAGE