22-3706
N Phone: e780-0021 FIRE-003706-2022 Issue Date: REINSPECTION FEES: (c) With respect to Reinspoction fees will comply with Florida Statute 563.80(2)(c) the o.cal government shall impof four times the amount♦ t for the initial Inspection or first reinspection, whichever Is greater,k • _ agenciesNotice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies. IIIII IIIIIIII;+ \ P accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. �� '�►�lku�+lii INSPECTION'RES IN 6 MONTHS WITHOUT APPROVED INSPECTION FOR . 8 HOUR NOTICE U O m 0 O m W 0 I-_ CO Q rn O co N 0 N Cl) N N UJ F— Z_ F— U) J 'r Johnson 0),Nto Controls DRAWING INDEX Cheat I ict Tahlo Sheet Number Sheet Title General Information (FA-000 Series) FA-001 I COVER SHEET Floorplans (FA-100 Series) FA-101 DEVICE PLACEMENT PLAN - OR 8 & OR 9 FA-102 I DEVICE PLACEMENT PLAN - ROOF Typical Details (FA-700 Series) FA-701 I WIRING TYPICALS GENERAL NOTES 1. THESE DRAWINGS DEPICT GENERAL LOCATIONS OF LIFE SAFETY EQUIPMENT & FIELD DEVICES. EXACT ROUTING OF CONDUITS IS TO BE DETERMINED IN THE FIELD BY THE INSTALLING CONTRACTOR TO SUIT CONDITIONS. ALL CHANGES SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. 2. SHOULD ANY CONDITIONS EXIST THAT DIFFER FROM WHAT IS INDICATED ON THESE DRAWINGS WHICH CAUSE MAJOR DEVIATIONS IN THE WORK SHOWN, THE CONTRACTOR SHALL CONTACT JOHNSON CONTROLS IN A TIMELY MANNER SO AS NOT TO IMPAIR THE CONSTRUCTION SCHEDULE. 3. CONTRACTOR IS RESPONSIBLE FOR MAKING AND OBTAINING APPROVAL FOR ALL NECESSARY ADJUSTMENTS IN CIRCUITING AS REQUIRED TO ACCOMMODATE THE RELOCATION OF EQUIPMENT AND/OR DEVICES WHICH ARE AFFECTED BY ANY AUTHORIZED CHANGE. ALL CHANGES SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. 4. A STAMPED SET OF APPROVED FIRE ALARM DRAWINGS SHALL BE AT THE JOB SITE AND SHALL BE USED FOR INSTALLATION. 5. THE POWER CIRCUIT TO THE FACP AND TO THE FIRE ALARM POWER SUPPLIES SHALL BE ON A DEDICATED 120V, 20A BRANCH CIRCUIT BREAKER, AND SHALL HAVE A RED MARKING, LOCK -ON PROVISION AND SHALL BE IDENTIFIED AS "FIRE ALARM CIRCUIT CONTROL." THE LOCATION OF THE CIRCUIT DISCONNECT MEANS (CIRCUIT BREAKER) SHALL BE PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL UNIT. 6. UPDATE THE AS -BUILT DRAWING SET DAILY WITH JOB PROGRESS, RETURN THE AS -BUILT DRAWING SET TO JOHNSON CONTROLS NO LATER THAN 7 DAYS AFTER FINAL TEST. 7. THE CONTRACTOR WILL MAINTAIN ALL AREAS OF THE BUILDING IN A NEAT AND WORKMANLIKE MANNER. 8. DO NOT APPLY POWER EXCEPT IN THE PRESENCE OF A FACTORY TRAINED JOHNSON CONTROLS TECHNICAL REPRESENTATIVE. 9. ANY SMOKE DETECTOR HEAD INSTALLED BEFORE THE BUILDING IS CLEANED AND ACCEPTED SHALL BE COVERED TO PROTECT FROM DUST. ANY FALSE ALARMS DUE TO DIRT CONTAMINATED HEADS SHALL BE THE RESPONSIBILITY OF THE FIRE ALARM INSTALLER. 10. THE FIRE ALARM INSTALLER WILL MAINTAIN THE FIRE RESISTANCE INTEGRITY OF ALL WALL, CEILING, AND ROOF ASSEMBLIES ANY TIME THAT WORK IS NOT ACTIVELY BEING PERFORMED. 11. INSTALLATION F DEVICES SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. POWER LIMITED AND 0 0 CCO U NON -POWER LIMITED FIELD WIRING MUST BE INSTALLED WITHIN THE FACP ENCLOSURE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND APPLICABLE ELECTRICAL CODES. REFER TO'APPLICABLE CODES & STANDARDS' FOR SPECIFIC CODE REFERENCES. 12. ALL WIRING SHALL BE INSTALLED ACCORDING TO APPLICABLE ELECTRICAL CODES. 13. FIRE ALARM CIRCUITS SHALL BE IDENTIFIED IN ACCORDANCE WITH APPLICABLE ELECTRICAL CODES. MARK ALL FIRE ALARM WIRES IN ACCORDANCE WITH APPLICABLE ELECTRICAL CODE SECTIONS FOR POWER LIMITED AND NON -POWER LIMITED WIRE. 14 FIRE ALARM CABLE INSTALLED IN DUCTS, PLENUM, AND OTHER SPACES USED FOR ENVIRONMENTAL AIR SHALL BE TYPE FPLP. 15. FIRE ALARM CABLE INSTALLED IN THE VERTICAL RUNS AND PENETRATING MORE THAN ONE FLOOR OR CABLES INSTALLED IN VERTICAL RUNS IN SHAFTS SHALL BE TYPE FPLR. 16. FIRE ALARM CABLE INSTALLED IN UNDERGROUND CONDUIT OR OTHER WET LOCATIONS SHALL BE UL LISTED FOR WET LOCATIONS. 17. FIRE ALARM CIRCUITS EXTENDING BEYOND ONE BUILDING AND RUN OUTDOORS SHALL BE INSTALLED IN ACCORDANCE APPLICABLE ELECTRICAL CODES, WHERE APPLICABLE. 18. ALL WIRING, INCLUDING SHIELDS MUST BE DRY AND FREE OF SHORTS AND GROUNDS. 19, ALL SHIELDED WIRE MUST HAVE SHIELD CONTINUITY AT FULL LENGTH OF THE WIRE. 20. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. 21, 120VAC IS NOT PERMITTED IN THE SAME CONDUIT WITH LOW VOLTAGE WIRING. 22. MAINTAIN MAXIMUM CONDUIT FILL RATIO AS PER APPLICABLE ELECTRICAL CODES REQUIREMENTS. 23. EXISTING CONDUITS MAY BE USED BY THE INSTALLATION CONTRACTOR AS DEEMED NECESSARY; HOWEVER, ANY EXISTING CONDUIT WILL BE USED ONLY IF CONDUITS MEET CURRENT STANDARDS AND CODES. JOHNSON CONTROLS MAKES NO STATEMENTS WRITTEN OR VERBAL AS TO THE CONDITION OF EXISTING CONDUITS. IMPORTANT NOTICE TO USER: This information may not be sold or transferred to any third party, used bn other projects or additions to the project for which it was prepared, or used for completion of this project by any third party. Johnson Controls disclaims all liability for the use or reuse of altered files by the user or any third party and such use will be a user's sole risk. User shall, to the fullest extent permitted by law, defend, indemnify, and hold Joh.,9son Controls harmless from any and all claims for loss, damage or injury arising directly or indirectly from any such unauthorized use. LEGENDS APPLICABLE CODES & STANDARDS JURISDICTIONS WITHIN THE STATE MAY HAVE AMENDMENTS TO THE STATE ADOPTED CODE. CHECK WITH THE LOCAL JURISDICTION AUTHORITY FOR MORE DETAILS. FLORIDA FIRE PREVENTION CODE, SEVENTH EDITION (2020) -NFPA 1, FIRE CODE, 2018 EDITION FIRE ALARM SYMBOL LEGEND-NFPA 101,LIFE SAFETY CODE, 2018EDITION SYMBOL DESCRIPTION BRAND MODEL BACKBOX WIRE FLORIDA BUILDING CODE, SEVENTH EDITION (2020) TYPE -INTERNATIONAL BUILDING CODE (IBC), 2018 EDITION NOTIFICATION APPLIANCES -NFPA 70, NATIONAL ELECTRIC CODE, 2017 EDITION -NFPA 72, NATIONAL FIRE ALARM AND SIGNALING CODE, 2016 EDITION # I CONVENTIONAL MULTI -CANDELA STROBE ,WALL MOUNT, RED, CLEAR SIMPLEX 4906-9101 SINGLE GANG 1-1/2" D V LENS, FIRE j ACCEPTABLE CABLE TYPES o FIRE ALARM WIRE LEGEND 0 CIRCUIT DESCRIPTION CONSTRUCTION GAUGE CIRCUIT PROPERTIES LL a- ~ o V VISUAL 2 COND. SOLID 14 AWG X L CONDUIT SIZE MAX CONDUCTOR AREA CONDUIT SIZE MAX CONDUCTOR AREA 1/2" j 0.122 SQ. INCH* 1-1/4" 0,598 SQ INCH* 3/4" 0.213 SQ INCH* 1-1/2" 0.814 SQ INCH* 0.346 SQ INCH* 2" 1.342 SQ INCH* * 40% CONDUIT FILL PER N.E.C. STP = SHIELDED TWISTED PAIR ITEMS SUCH AS CAPACITANCE BETWEEN CONDUCTORS AND WIRE GAUGE CAN BE CRUCIAL TO THE CIRCUIT DESIGN OF THIS SYSTEM INSTALLATION. THE INSTALLING CONTRACTOR IS RESPONSIBLE FOR SELECTING AND INSTALLING CABLE MANUFACTURER AND MODEL THAT MEETS OR EXCEEDS THE ABOVE REQUIREMENTS. RECOMMENDED CABLE MANUFACTURERS AND MODEL NUMBERS ARE AVAILABLE UPON REQUEST. 61G15 NOTES 61G15-32.008 DESIGN OF FIRE ALARM SYSTEM (1) Fire alarms and detection systems include fire protection supervision, emergency alarm circuits, activation of life safety system controls and remote signaling of emergency conditions. Items to be considered in the design or analysis of fire alarm and detection systems are, as applicable to the particular project: occupancy and classification, monitoring, control and communication, cabling and supervision requirements, installation requirements, interoperability and performance requirements. (2) The design specifications shall be based on the Florida Building Code, the Florida Fire Prevention Code, or as required by the local authority having jurisdiction. The Florida Building Code and the Florida Fire Prevention Code are incorporated by reference in rule 61 G15-18.011, F.A.C. (3) For systems below the threshold requirements for mandatory use of professional engineering services, the Engineer of Record may specify the minimum system requirements only. (4) To ensure minimum design quality of Fire Alarm and Detection Systems Engineering Documents, said documents shall include as a minimum the following information when applicable: INCLUDED N/A - (a) The documents shall be clear, with a symbols legend, system riser diagram showing all initiation and notification components, and cabling requirements. The documents shall indicate locations where fire ratings are required as determined by the system's survivability requirements, and shall identify the general occupancy of the protected property and each room and area unless it is dear from features shown. NCLUDED Ll NIA (b) Locate initiation and notification devices and connections to related systems on the floor plans and sections when needed for clarity. Related systems include elevator controls, smoke control systems, dampers, door release, any other systems or elements directly or indirectly controlled or monitored. INCLUDED N/A (c) Strobe intensity and speaker output ratings for all notification devices. INCLUDED M N/A (d) Identify the Class of circuits as listed in NFPA 72, which is contained within and incorporated into the Florida Fire Prevention Code. INCLUDED CJ N/A (a) Identify the functions required by the alarm and control systems including the transmission of emergency signals being monitored or annunciated. INCLUDED N/A (f) Indicate whether the fire alarm is conventional or addressable, and indicate all zoning. INCLUDED N/A (g) Locate surge protective devices and required protective features. h Identify and locate system vices a e subject to environmental factors and indicate requirements for the protection of equipment from em temperature, humidity or corrosive INCLUDED N/A O ty y mde I that su � q pt p ty atmospheres, including coastal salt air. INCLUDED n NIA (i) The documents shall include a site plan of the immediate area around the protected building, structure or equipment when alarm devices are required outside the structure. INCLUDED M N/A 0) In buildings where smoke detection will be obstructed by walls, beams or ceiling features, the Engineer of Record shall provide applicable design and detailsto direct the Installer to mitigate the obstructions. In buildings with smoke detection under a pitched roof, the plans shall indicate the roof pitch and a building section shall be provided as part of the Engineering Design Documents. k or fire detection systems utilizing e detection in situations where smoke stratification is anticipated, the design shall provide the necessary criteria to mitigate the detection INCLUDED N/A () F y ms u Ing smoke d tecG p g p ry g problems. INCLUDED WA I stems designed using Performance Based criteria shall be identified and referenced to design guides or standards approved b the local authority having jurisdiction consistent with S m n r O Y 9 9 9 9 PP Y Y 91 standards adopted by the Florida Fire Prevention Code and the Florida Building Code. INCLUDED El N/A m The system design u is to provide a general evacuation signal or a zoned evacuation for all high-rise buildings o multi -tenanted properties as defined in section O y g must indicate if the system p g Ig g g r I p p 2 of the Florida Building Code, Building. []INCLUDED ®N/A (n) Wiring requirements for underground, wet locations campus style wiring, protection against damage and burial depth shall be specified or indicated on the engineering design documents. NCLUDED 0 N/A (o) Requirements for operations and maintenance procedures, manuals, system documentation, and instruction of Owner's operating personnel, as needed to operate the systems as intended over time. INCLUDED ON/A (5) In the event that the Engineer of Record elects to specify specific equipment and to show the required wiring, battery and voltage drop (circuit analysis) calculations shall be completed. The calculations shall be completed using the equipment manufacture's data and applicable NFPA 72 procedures. NCLUDED ❑ N/A (6) System test requirements shall be noted on the Engineering Design Documents. NCLUDED I NIA (7) When the Engineer of Record determines that special requirements are required by the owner, insurance underwriter or local fire code amendments these requirements shall be documented or referenced on the Engineering Design Documents. FIRE ALARM 61 G 15 NOTES— (4) (A) FIRE ALARM LEGEND ARE LOCATED ON FA-001 AND. (B) ALL INITIATING DEVICES AND NOTIFICATION APPLIANCES ARE LOCATED ON THE FLOOR PLAN PAGE FA-101. (C) ALL CANDELA RATINGS HAVE BEEN IDENTIFIED WITH EACH DEVICE TO MEET THE STANDARDS OF CHAPTER 18 NFPA 72. (D) CLASS OF CIRCUITS WILL BE CLASS B. (E) THE MATRIX IS SHOWN ON FA-001 AND FACILITY IS MONITORED BY TWO TELCO PHONE LINES. (F) THE FIRE ALARM SYSTEM WILL BE ADDRESSABLE ON 1 LOOP. (G) (2)120V SURGE SUPPRESSORS WERE ADDED TO THE TRANSPONDER FIRE ALARM PANEL AND NAC EXTENDER PANEL. (H) NIA (1) SITE PLAN IS LOCATED ON FA-001. (J) NIA (K) NIA (L) NIA (M) THE FIRE ALARM SYSTEM WILL BE GENERAL ALARM. (N) N/A (0) THE APPLICABLE MANUALS FOR THE FIRE ALARM SYSTEM WILL BE SENT WITH CLOSEOUT DOCUMENTS ON COMPLETION OF THE PROJECT. (6) TESTING PER NFPA 72, 2016 EDITION © Johnson Controls 2021. All rights reserved. Reuse, copying, modification or alteration of the drawings and other information contained herein is strictly prohibited. SYSTEM SURVIVABILITY SCALE O Non Sprinkled, No P.elocation or Partial Evacuation 1 Sprinkled, No Fclocation or Partial Evacuation 2 Sprinkled, Voice Evacuation with partial or designated relocation areas 3 5prinkled, Voice Evacuation with partial or designated relocation areas OCCUPANCY TYPE(S): 1-2 INSTITUTIONAL GROUP SPRINKLER PROTECTION: BUILDING IS FULLY SPRINKLERED SCOPE OF WORK REMOVE 5 EXISTING HEAT DETECTORS IN SHELL SPACE, MOVE FROM PROGRAMMING, AND MAKE WIRING SAFE FOR CONDUIT DEMOLITION. HAND ALL REMOVED EQUIPMENT TO THE OWNER. RELOCATE 1 EXISTING ADDRESSABLE MANUAL PULL STATION AND CHANGE PROGRAMMING LABEL TO MATCH THE NEW LOCATION. JOHNSON CONTROLS CONTACTS Sales Representative Drawings Prepared By GREGORY JOHN TALAGA CHAITANYA GODBOLE GREGORY.TALAGA@JCI.COM CHAITANYA.GODBOLE@JCI.COM PHONE:813-731-5540 PHONE:206-626-3328 Project Manager Drawings Reviewed By LEE SELLERS JACK JECKEL KENNETH.LEE.SELLERS@JCI.COM JACK.JECKEL@JCLCOM PHONE:813-313-1629 PHONE:813-313-1643 PROJECT DIRECTORY Site Johnson Controls District - 292 ADVENT HEALTH - ZEPHYRHILLS PHARMACY 7050 GALL BOULEVARD 10500 UNIVERSITY CENTER DR., SUITE 275 ZEPHYRHILLS, FLORIDA 33541 TAMPA, FL 33610 PHONE: 813-626-5482 FAX: 813-971-8780 SERVICE: 813-626-5482 Engineer of Record DCL ENGINEERING LLC 800 HIGHLAND AVE SUITE 102 ORLANDO, FLORIDA 32803 Successor Engineer Of Record CURTIS ENGINEERING SERVICE, LLC 29775 BAYHEAD ROAD DADE CITY, FLORIDA 33523 JOHNSON CONTROLS 10500 UNIVERSITY CENTER DRIVE, SUITE 275 TAMPA, FLORIDA 33610 ABBREVIATIONS LEGEND DEVICE TAG LEGEND AC = ABOVE CEILING NEC = NATIONAL ELECTRIC CODE AFF = ABOVE FINISHED FLOOR NFPA = NATIONAL FIRE PROTECTION ASSOCIATION PANEL DESIGNATOR AHJ = AUTHORITY HAVING JURISDICTION NIC = NOT IN CONTRACT . FA: = FACP (NON -NETWORK) ALM = ALARM NPU = NETWORK PROCESSING UNIT ANN = ANNUNCIATOR NTS = NOT TO SCALE • #: =NODE NUMBER BMS = BUILDING MANAGEMENT SYSTEM PAP = PRE -ACTION PANEL • T#: = TRANSPONDER NUMBER C = CEILING MOUNTED RC = EXISTING TO REMOVE AND COVER • #:T# = NODE:TRANSPONDER NUMBER CD = CANDELA RATING RD = EXISTING DEVICE TO BE RELOCATED • N#: = NAC EXTENDER NUMBER DET = DETECTOR RL = RELOCATED DEVICE CIRCUIT DESIGNATOR DGP = DATA GATHERING PANEL RR = REMOVE EXISTING & REPLACE WITH NEW • D# = DOOR HOLDER CIRCUIT NUMBER E = EXISTING TO REMAIN SCC = STATUS COMMAND CENTER • F# -FIRE PHONE CIRCUIT EOL = END OF LINE SLC = SIGNALING LINE CIRCUIT • H# = AUDIBLE (HORN) CIRCUIT NUMBER EPO = EMERGENCY POWER OFF SMK = SMOKE ER = ELEVATOR RECALL SUPV = SUPERVISORY • M#= IDNET LOOP NUMBER FAA = FIRE ALARM ANNUNCIATOR TAC = TRUEALERT ADDRESSABLE CONTROLLER • P# = POWER CIRCUIT NUMBER FACP = FIRE ALARM CONTROL PANEL TOS = TOP OF SHAFT • S# = SPEAKER CIRCUIT NUMBER FATC = FIRE ALARM TERMINAL CABINET TRBL = TROUBLE • V# = VISUAL CIRCUIT NUMBER FBO = FURNISHED BY OTHERS TS = TAMPER SWITCH • Z# = ZONE NUMBER FCC = FIRE COMMAND CENTER TYP = TYPICAL FSD = FIRE SMOKE DAMPER LION = UNLESS OTHERWISE NOTED DEVICE NUMBER FTR = FIRE ALARM TRANSPONDER VCC = VOICE COMMAND CENTER BRANCH I ISOLATED LOOP DESIGNATOR: H = HIGH HUMIDITY VT = VALVE TAMPER • (L#) = IDNET ISOLATED LOOP NUMBER HT = HEIGHT W = WATTAGE HVAC = HEATING VENTILATION & AIR CONDITIONING W/ = WITH IMS = INFORMATION MANAGEMENT SYSTEM W/O = WITHOUT MAX = MAXIMUM WF = WATERFLOW MIN = MINIMUM WG = WIRE GUARD 1:T2:V12-1(L1) N/A = NOT APPLICABLE WP = WEATHERPROOF NAC = NOTIFICATION APPLIANCE CIRCUIT XP = EXPLOSION PROOF NDU = NETWORK DISPLAY UNIT SYSTEM SEQUENCE OF OPERATIONS 0 O O o F— o O aZJ o Oz p cC', coCn d < J0 `C z �aZQ n'Dzzz(of wco W Q �='' U Zzoz z¢ i i- 0O O a J n¢ n LU z z o n ¢ Z O U)- 0`o o) w `n ¢ 0_ n 0- n J W O U O _ J fn 2 W K m m - > ¢ ~ J Z gd O O. Lu w w r¢- z X CDz¢ CO F-¢ oa m o o w z O J O J O J D_ 0 O Cn w cG CG m O m m m rl zD ¢ > C.� im a_�O Z CD 0 0 J J z ¢ J � OU Q 00 Q OU ¢ Q Q ¢Lu U H c=i) w w o> W W co o 0 0 0 0 o z W ¢ ¢ ¢ ¢ ¢ (¢ ¢ ¢ ¢ w w w w w w w = w Z Z Z ZD M = Z M Cn V> 000 to cn In n. F-- F r F—F � o ¢ > > > > > > CTRL UNIT ANNUNCIATION NOTIFICATION FIRE SAFETY CONTROL SYSTEM INPUTS A I B I C D E F I G H( I J K L M N 0 P Q R I S T U V 1 MANUAL PULL STATION X X X X X X X 2 FIRE ALARM AC POWER FAILURE X X X X 3 FIRE ALARM SYSTEM LOW BATTERY X X X X 4 OPEN CIRCUIT OR GROUND FAULT X X X X 5 CLASS B NOTIFICATION CIRCUIT (NAC) - SHORT - X X X X j MATCH EXISTING SEQUENCE OF OPERATIONS. ALL WORK SHALL COMPLY WITH NFFA CODES AND STANDARDS n.'7 is I7 e „ � -AN 1) CURTIS ENGINEERING SERVICE, LLC - CA#31561 JAMES M. CURTIS, P.E. - PE#37912 29775 BAYHEAD ROAD DADE CITY, FLORIDA 33523 SUCCESSOR ENGINEER OF RECORD This item been electronically signed and sealed by James igital �nrtis, P.E.tusing�ri Digitally signed digital si �� at right: by James Curtis w a No, 37912 Rom° Date: STATE OF 'd >�,s �.ZORI'D �• e, 2021:12 30 Print et ",t�� ®�I t i , o'&ent are _ l 1 not conslldd �ldAA nd sealed, 1 0: 1 7:16 0500 the signature must be verified on any electronic copies. N C O O IIA ate,, C C 0 OV 0 s W 0 ry ay CO �� co N h ch m fin N W wZ !=Ox C/) CL L _ IY 0 w Z N W co U -, u7 ~ � N N �c0C N WMro >__J F— Z L.L. LL1 odd N L�� G NFU) Cl) FFFFFFFFF� U W � N co J r J � M M = d. ® IW Q W N' 0 J LL o Q O J Z 08 W m J W oo � W a 3: ® Q ® LO CL W < 4 Z 0 a_ fY V Cn W 0 DRAWN BY: CHAITANYA GODBOLE CHECKED BY: JACK JECKEL ISSUE DATE: 12/23/21 JOB #: PROJECT #: 292:650110515 JOHNSON CONTROLS © 2021 SYSTEM: FIRE ALARM SYSTEM SHEET: COVER SHEET FA-001 U O m 0 O C7 Mm 0 w aC H U g Z DEVICE PLACEMENT PLAN - OR 8 & OR 9 5 SCALE:1/4" = V-0" © Johnson Controls 2021. All rights reserved. Reuse, copying, modification or alteration of the drawings and other information contained herein is strictly prohibited. SCALE:1/4" = V-0" IN FEET 0 2' 4' 8' 1. ALL CEILINGS ARE ASSUMED TO BE 10' A.F.F., SMOOTH CONSTRUCTION UNLESS _ NOTED OTHERWISE. 2. THE DEVICE ADDRESSES INDICATED ON THESE DRAWINGS ARE AN ALPHANUMERIC DESCRIPTION OF WHICH CIRCUIT THE DEVICE IS LOCATED ON. DEVICES MAY BE ASSIGNED A DIFFERENT NUMBER WITHIN THE PANEL PROGRAM. CONSULT WITH A JOHNSON CONTROLS TECHNICIAN BEFORE APPLYING A PHYSICAL LABEL TO ANY DEVICES. 3. REMOVE 5 EXISTING HEAT DETECTORS IN SHELL SPACE AREA AND RETURN TO tA OWNER. C 0 KEYNOTES: 1O RELOCATE EXISTING ADDRESSABLE PULL STATION. O OV FIRE ALARM SYMBOL LEGEND SYMBOL DESCRIPTION BRAND MODEL BACKB:7:_�_JWIRETYP TY INITIATING DEVICES F RL EXISTING RELOCATED ADDRESSABLE MANUAL PULL STATION EXISTING—! EXISTING — — EXISTING M MODULES AND RELAYS _ RELAY IAM SIMPLEX 4090-9002 4" SO. 2-1/8" D W/ DBL. GANG COVER M R ACCEPTABLE CABLE TYPES o FIRE ALARM WIRE LEGEND ! a a ,o a CIRCUIT DESCRIPTION CONSTRUCTION GAUGE CIRCUIT PROPERTIES M IDNET UTP SOLID 18 AWG 60�F MAX TOTAL LINE X X CAPACITANCE R RELAY 2 COND. SOLID 14 AWG X X X X CONDUIT SIZE MAX CONDUCTOR AREA CONDUIT SIZE j MAX CONDUCTOR AREA 1/2" 110.122 SQ. INCH* 1-1/4" — 0.598 SQ INCH* 3/4" _ 0.213 SQ INCH* 1-1/2" 0.814 SQ INCH* 1" 0.346 SQ INCH* 2" 1.342 SQ INCH* * 40% CONDUIT FILL PER N.E.C. STP = SHIELDED TWISTED PAIR ITEMS SUCH AS CAPACITANCE BETWEEN CONDUCTORS AND WIRE GAUGE CAN BE CRUCIAL TO THE CIRCUIT DESIGN OF THIS SYSTEM INSTALLATION. THE INSTALLING CONTRACTOR IS RESPONSIBLE FOR SELECTING AND INSTALLING CABLE MANUFACTURER AND MODEL THAT MEETS OR EXCEEDS THE ABOVE REQUIREMENTS, RECOMMENDED CABLE MANUFACTURERS AND MODEL NUMBERS ARE AVAILABLE UPON REQUEST. KEY PLAN - LEVEL 2 0 T SCALE: N.T.S. TRUE PROJECT NORTH NORTH CURTIS ENGINEERING SERVICE, LLC - CA#31561 JAMES M. CURTIS, P.E. - PE#37912 29775 BAYHEAD ROAD DADE CITY, FLORIDA 33523 SUCCESSOR ENGINEER OF RECORD This item been electronically signed and sealed by James M. Curtis, P.E. using a digital Wo*j Digitally signed sij at right: by James Curtis -'w P No. d37912 'Date: STATE OF �'/ .46 aZORI'D 2021.1230 Print ot co>��d61�� iAd'an$d, sealed,re 10 :17 : 51 - 0 5' 0 0' the signature must be verified on any electronic copies. coco �Cp MM Coco Ln CV wz �aU_ 0 HI w F- z C., w co U L? ~ O N N :W> _ J z u- w U_ =)QU R' OaLO GoQCLOU z V a Q _ L0 M = IO Q CL in 0 Lij J L.L. a�Cl) LL m J J Z L L1 (� O = > LOUj �. Q® N DRAWN BY: CHAITANYA GODBOLE CHECKED BY: JACK JECKEL ISSUE DATE: 12/23/21 JOB #: PROJECT #: 1 292:650110515 JOHNSON CONTROLS © 2021 SYSTEM: FIRE ALARM SYSTEM SHEET: DEVICE PLACEMENT PLAN - OR8&OR9 FA-101 Q M_ O_ 00 N O N M N N LLI F- z ry a <c N DEVICE PLACEMENT PLAN - ROOF 5 SCALE:114" = V-0" © Johnson Controls 2021. All rights reserved. Reuse, copying, modification or alteration of the drawings and other information contained herein is strictly prohibited. SCALE:1/4" = V-0" IN FEET 0 2' 4' 8' I1. 1. ALL CEILINGS ARE ASSUMED TO BE 10' A.F.F., SMOOTH CONSTRUCTION UNLESS NOTED OTHERWISE. 2. THE DEVICE ADDRESSES INDICATED ON THESE DRAWINGS ARE AN ALPHANUMERIC DESCRIPTION OF WHICH CIRCUIT THE DEVICE IS LOCATED ON. DEVICES MAY BE ASSIGNED A DIFFERENT NUMBER WITHIN THE PANEL PROGRAM. CONSULT WITH A JOHNSON CONTROLS TECHNICIAN BEFORE APPLYING A PHYSICAL LABEL TO ANY DEVICES. 3. REMOVE 5 EXISTING HEAT DETECTORS IN SHELL SPACE AREA AND RETURN TO OWNER. KEYNOTES: ORELOCATE EXISTING ADDRESSABLE PULL STATION. SYMBOL j DESCRIPTION BRAND MODEL_ BACKBOX WIRE 1 TYPE J INITIATING DEVICES F RL EXISTING RELOCATED ADDRESSABLE MANUAL PULL STATION EXISTING EXISTING EXISTING —_� MODULES AND RELAYS RELAY IAM SIMPLEX 4090-9002 4" SQ. 2-1/8" D W/ DBL. GANG COVER M ACCEPTABLE CABLE TYPES FIRE ALARM WIRE LEGEND a a a z F F 0 o �; CIRCUIT DESCRIPTION CONSTRUCTION GAUGE CIRCUIT PROPERTIES M IDNET UTP SOLID 18 AWG 60pF MAX TOTAL LINE CAPACITANCE X X R RELAY CONDUIT SIZE 2 COND. SOLID 14 AWG MAX CONDUCTOR AREA CONDUIT SIZE--- X X X X MAX CONDUCTOR_ AREA _ 1/2" 0.122 SQ. INCH* 1-1(4" 0,598 SQ INCH* 3/4" 0.213 SQ INCH* 1-1/2" 0.814 SQ INCH* 1" 0.346 SQ INCH* 2" 1.342 SQ INCH*� * 40% CONDUIT FILL PER N.E.C. j STP = SHIELDED TWISTED PAIR ITEMS SUCH AS CAPACITANCE BETWEEN CONDUCTORS AND WIRE GAUGE CAN BE CRUCIAL TO THE CIRCUIT DESIGN OF THIS SYSTEM INSTALLATION. THE INSTALLING CONTRACTOR IS RESPONSIBLE FOR SELECTING AND INSTALLING CABLE MANUFACTURER AND MODEL THAT MEETS OR EXCEEDS THE ABOVE REQUIREMENTS. RECOMMENDED CABLE MANUFACTURERS AND MODEL NUMBERS ARE AVAILABLE UPON REQUEST, KEY PLAN - ROOF T T SCALE: N.T.S. TRUE PROJECT NORTH NORTH CURTIS ENGINEERING SERVICE, LLC - CA#31561 JAMES M. CURTIS, P.E. - PE#37912 29775 BAYHEAD ROAD DADE CITY, FLORIDA 33523 SUCCESSOR ENGINEER OF RECORD This item been electronically signed and sealed by James M. Curtis, F.E. using a digital si kt,p at right. ® t° No. 37912 °i y ® tl 3i o.w 8 F STATE OF e .k, ♦i Fx Print e �� 1 '4;gcnt are not consi wi nd sealed, the signature must be verified on any electronic copies. Digitally signed by James Curtis Bate: 20 1A'22130 10:18:03-05'00' co co co � �r-- \� ao m t A �/) rl' N C Lu z ~O>G 0 0 woo ® fo Ofo CV CEO t9 CN N CGS LLI m J U aLL mQC� tY o CL. > B oQU) i r I DRAWN BY: CHAITANYA GODBOLE CHECKED BY: JACKJECKEL ISSUE DATE: 12/23/21 JOB #: PROJECT #: 292:650110515 JOHNSON CONTROLS © 2021 SYSTEM: FIRE ALARM SYSTEM SHEET: I 0 Q M N O_ 66 N O N co N N w z r a J DEVICE MOUNTING HEIGHT REFERENCE PER NFPA 72 VISUAL APPLIANCE MOUNTING HEIGHT CONSIDERATIONS IN SLEEPING ROOMS 1. MIN DISTANCE IN SLEEPING ROOMS IS 24" (610mm) FROM CEILING TO TOP OF LENS FOR 110CD STROBES WITHIN 16' OF THE PILLOW 2. 177CD STROBES, USED IN SLEEPING ROOMS, CAN BE WITHIN THE 24" (610mm) MINIMUM DISTANCE FROM THE CEILING. THE HIGHER INTENSITY IS TO COMPENSATE FOR A POSSIBLE SMOKE LAYER. FOR CEILING HEIGHTS LESS THAN 86" NFPA 72 AUDIBLE APPLIANCE 6" MIN (2180mm), THE VISUAL LENS MOUNTING HEIGHT (152.4mm MIN) BELOW FINIShED CEILING SHALL BE WITHIN 6" (150mm) OF THE CEILING. AUDIBLE/VISUAL AUDIBLE ONLY & VISUAL ONLY APPLIANCES SYNCHRONIZE MORE THAN TWO APPLIANCES IN ANY FIELD OF VIEW. 96" MAX (ADA, IBC, NFPA) 90" MIN (2286mm MIN) (2440mm MAX) ABOVE FINISHED FLOOR ABOVE FINISHED FLOOR TO TOP OF LENS (OTHER MOUNTING HEIGHTS SHALL BE PERMITTED BY THE AHJ PROVIDING IT MEETS 80" MIN (ADA, IBC, NFPA) THE SOUND LEVEL OUTPUT REQUIRED.) (2032mm MIN) FIRE ABOVE FINISHED FLOOR PHONE TO BOTTOM OF LENS JACK NOTE: REFER TO THE PROPER DEVICE M INSTALLATION INSTRUCTIONS FOR BACKBOX MOUNTING HEIGHT. FINISHED FLOOR SIMPLEX 4090.9002 MOUNTING OPTION "A" IDNet SLC 7� �J L 1'♦��IDNet SLC (+) SERIES T-TAP (SPLI CONNECTION CONNECTION TERMINATION VIEW CLASS B WIRING WIRING NOTES 1. MAINTAIN CORRECT POLARITY ON TERMINAL CONNECTIONS. 2. ALWAYS CUT CONDUCTORS AND SECURE UNDER TERMINALS. NEVER LOOP WIRES UNDER TERMINALS. 3. ANY WIRE SPLICES TO BE MADE BY LISTED AND AHJ APPROVED METHODS. MOUNTING OPTIONS OPTION' DESCRIPTION NOTE A 4" (102mm) SQUARE BOX, 2-1/8" MINIMUM DEPTH WITH DOUBLE GANG COVER PLATE BY OTHERS 4" (102mm) SQUARE BOX, 2-1/8" MINIMUM DEPTH WITH SIMPLEX 4090-9801 TRIM PLATE BOX BY OTHERS, PLATES ORDERED B FOR SEMI -FLUSH MOUNTED BOX SEPARATELY 4" (102mm) SQUARE BOX, 2-1/8" MINIMUM DEPTH WITH SIMPLEX 4090-9802 TRIM PLATE BOX BY OTHERS, PLATES ORDERED C FOR SURFACE MOUNTED BOX ISEPARATELY 1. FOR ADDITIONAL MOUNTING OPTIONS, DOWNLOAD DATA SHEET 4090-0002 FROM HTTP://WWW.SIMPLEX-FIRE.COM © Johnson Controls 2021. All rights reserved. Reuse, copying, modification or alteration of the drawings and other information contained herein is strictly prohibited. A/C SUPPLY OR RETURN THE 4" REQUIREMENT FOR SMOKE DETECTORS HAS DIFFUSER BEEN REMOVED FROM THE 2010 EDITION OF NFPA 72 3' (914mm) 4 NOTE: MEASUREMENTS MINIMUM (102mm) SHOWN ARE TO THE CLOSEST CEILING EDGE OF THE DETECTOR, CEILING MOUNTED 4 SMOKE/HEAT (102mm) DETECTOR + ACCEPTED HERE 12" (305mm) HEAT DETECTORS MAXIMUM TO TOP OF SENSOR NEVER HERE / - TO EXIT DOOR 5' (MAX.) WALL MOUNTED 1524mm SMOKE/HEAT DETECTOR MAGNETIC 5" DOOR (127mm) HOLDER DOOR WIDTH MANUAL PULL LESS 3" STATION (76mm) 48" MAX (ADA) (1219mm) 48" MAX (NFPA, ADA) (1219mm MAX) 4T MIN (NFPA) (1067mm MIN) MEASUREMENTS SHOWN ARE TO TOP OF PULL HANDLE FINISHED WALL DIP SWITCH SETTINGS INITIATING SIMPLEX IDNet DIP ;WITCHE! 1 THRU 4 ON OFF SIDE WALL 1 2 4 8 16 32 64 128 1 2 3 4 5 6 7 8 g 1=ON O=OFF ADDRESS SHOWN ABOVE IS 120 SEE NOTE DO NOT USE ADDRESS 0 FOR AN IDNET ADDRESS DIP SWITCHES 5 THRU 8 iwww Mwww 61ww mmwO W i 1616 ON M w 000e 166M PH setae W61M M611 odes sass 0 16 32 48 64 80 96 112 128 144 160 176 192 208 224 240 JMW 1 17 33 49 65 81 97 113 129 145 161 177 193 209 225 241 2 18 34 50 66 82 98 114 130 146 162 178 194 210 226 242 3 19 1 35 51 1 67 83 1 99 115 1 131 147 1 163 179 1 195 211 1 227 243 Q Q O 4 20 36 52 68 84 100 116 1 132 148 164 180 196 212 228 244 S O Q 5 21 37 53 69 85 101 117 133 149 165 181 197 213 229 245 Q Q 6 22 38 54 70 86 102 118 134 150 166 182 198 214 230 246 Q 7 23 39 55 71 87 103 119 135 151 167 183 199 215 231 247 Q Q Q 8 24 40 56 1 72 88 104 120 136 152 168 184 200 216 232 248 Q Q 9 25 41 57 73 89 105 121 137 153 169 185 201 217 233 249 Q Q 10 26 42 58 74 90 106 122 138 154 170 186 202 218 234 250 Q 11 27 1 43 59 75 91 1 107 123 139 155 171 1 187 203 219 235 251 Q d 12 28 44 60 76 92 108 124 140 156 172 188 1 204 220 236 252 Q 13 29 45 61 77 93 109 125 141 157 173 189 205 221 237 253 O 14 30 46 62 78 94 110 126 142 158 174 190 206 222 238 254 Kill 15 31 47 63 79 95 111 127 143 159 1 175 191 207 223 239 255 NOTE: THE 4098-9771, -9794, -9795, -9798 SOUNDER BASES HAVE A 9-POSITION DIP SWITCH. THE FIRST EIGHT DIP SWITCHES SET THE SOUNDER BASE ADDRESS. DIP SWITCH POSITION 9 IS SET TO OFF OR ON DEPENDING UPON THE SOUNDER BASE POWER SOURCE. WHEN THE SOUNDER BASE IS CONNECTED TO A 24 VDC POWER SOURCE, DIP SWITCH POSITION 9 IS SET TO "OFF" AND THE 24 VDC POWER IS SUPERVISED BY THE SOUNDER BASE. WHEN THE SOUNDER BASE IS POWERED BY THE PANEL'S NOTIFICATION APPLIANCE CIRCUIT (NAC), DIP SWITCH POSITION 9 IS SET TO "ON" AND THE POWER IS SUPERVISED BY THE NAC AND NOT THE SOUNDER BASE. THE 4098-9770 AND -9797 BASES HAVE THE SAME LAYOUT, BUT DOESN'T OFFER SOUNDER FUNCTIONALITY. THEY USE AN 8-WAY DIP SWITCH ONLY. SIGNALING LINE CIRCUITS SHIELDING EXAMPLE USE ONLY UL LISTED FIRE ALARM TRIM AWAY ONLY TWISTED SHIELDED PAIR CABLE O THE SHIELD AND II STRIP THE INSULATED WIRES D(TSP) FOR IDNET, DATA COMM. KEEP THE DRAIN REUSE INSULATION—,, SHILD DISCARD f DRAIN WIRE ® DRAIN WIRE �7 ABOUT 5/16" TO 3/8" FOR 1 LINES, AUDIO, PHONE &SPEAKER WIRE UNDAMAGED. (D x INSERTION INTO BOX -TYPE OR WIRING IN A FIRE ALARM SYSTEM. \ D PUSH REUSED �I SCREW -CLAMP TERMINALS ON MIN. SIZE IS 18-2 AWG SOLID STP. O3 5 1 ELECTRICAL TAPE. '' THE ADDRESSABLE DEVICE. SHIELDJ/PR DRAIN WIRE O INSULATION CUT CAREFULLY DOWN II i I> PREPARE THE GABLE � L i'(NTO JACKET. SECURE Y THE SHIELD/DRAIN IS DRAIN WIRE ;I�. :>I BY REMOVING 2" TO 4" (-) OF JACKET AS NEEDED. �j 46 BLAC WITH ELECTRICAL � NEVER CONNECTED TO STRIP OFF APTAPE. THE DEVICE. EXAMPLE: #18 2 AWG SHIELDED 1 2 INCHES OREDUCE EXPOSED WIRESTWISTED-PAIR CABLE INSULATION TIN ABOUT 5NT TO X- FORTRIM THE BARE DRAIN TO ABOUT INSERTION INTO BOX -TYPE OR 1-1/2".JOIN THEM WITH AN ONTO DRAIN SCREW -CLAMP TERMINALS. GENERAL WIRING GUIDELINES ELECTRICAL CONNECTOR LISTED 1. ALL WIRING IS TO BE COPPER CONDUCTOR. ALL EQUIPMENT MUST BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATIONS AND APPROVED FOR WIRE SPLICING. AND THE SPECIFICATIONS AND STANDARDS OF THE AUTHORITY HAVING JURISDICTION. THE INSTALLATION OF ALL WIRING, CABLE AND EQUIPMENT EXAMPLE FOR MUST BE IN ACCORDANCE WITH NFPA 70, NATIONAL ELECTRICAL CODE NEC), AND SPECIFICALLY WITH ARTICLE 760, FIRE ALARM PROTECTIVE WIRING LABELING SECURE THE DRAIN WIRES INTO THE SIGNALING SYSTEMS; ARTICLE 800, COMMUNICATION CIRCUITS, WHERE APPLICABLE. Q CONNECTOR APPROVED FOR THE 2. IF SHIELDED WIRE IS USED, THE FOLLOWING MUST BE OBSERVED: WIRE TAG - PURPOSE. WIRES MUST BE TIGHT ENOUGH N INSULATED THROUGHOUT THE ENTIRE LENGTH OF THE CABLE. 2.1. METALLIC CONTINUITY OF THE SHIELD MUST BE MAINTAINED AND SUN1'M2 TO HOLD SECURELY AND NOT SLIP OUT OF 2.2. SHIELDS SHALL ONLY BE CONNECTED AT THE CONTROL UNIT. SHIELD MUST NOT BE CONNECTED TO, OR TOUCH CONDUIT, ELECTRICAL BOXES, THE CONNECTION. ENSURE BARE DRAINS OR ASSOCIATED HARDWARE AT ANY POINT. _ TO PREVENT CONFUSION ARE SECURED AND UNABLE TO MAKE 2.3. THE ENTIRE LENGTH OF THE CABLE MUST HAVE A RESISTANCE GREATER THAN 1 MEGAOHM TO EARTH. AND POSSIBLE ERRORS, EXTERNAL CONTACT. SEE NOTE 2 2.4. ALL CONDUCTORS ARE TO BE FREE OF SHORTS AND GROUNDS. ALL WIRES MUST BE 3. UNDERGROUND WIRING MUST BE LISTED FOR APPLICATION AND FREE OF ALL WATER. TAGGED. SEE WIRE WIRES MUST BE CONNECTED SEPARATELY 4. WIRING OTHER THAN THAT CONNECTED TO ELEVATOR CABS MUST NOT BE RUN IN ELEVATOR SHAFTS (REF.NFPA 70, ARTICLE 620). LEGEND FOR TYPES. UNDER TERMINALS, A CONTINUOUS WIRE 5. WIRING IN DUCTS, PLENUMS AND OTHER AIR HANDLING SPACES MUST BE LISTED FOR PLENUM USE AND INSTALLED IN ACCORDANCE WITH NFPA 70, LOOP IS NOT ALLOWED. ARTICLE 300. PRODUCT INFORMATION O 6. SPLICING IS PERMITTED IN ACCORDANCE WITH NFPA 70. ALL JUNCTIONS MUST BE INSULATED AS SOUNDLY AS THE ORIGINAL JACKET. CONTINUITY OF CLASS 'B' CLASS 'A' ANY SHIELD (WHERE USED) MUST BE MAINTAINED. WIRING TECHNIQUES FOR SHIELDED CABLE: + + - - + + - - 7. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. • SHIELDS AND DRAINS MUST NEVER TOUCH ONLY CLASS B IDNET, 8. THE COMMUNICATION CIRCUIT MEETS THE OPERATIONAL CHARACTERISTICS DEFINED FOR A STYLE 4 AND STYLE 6 SIGNALING LINE CIRCUIT. MAXIMUM GROUND. MAPNET OR DATA WIRE RUN NOT TO EXCEED 2500 FT. 1• MOST GROUNDS ARE DUE TO SHIELDING ISSUES. COMM. CABLE MAY BE 9. ALL CIRCUITS ARE SUPERVISED AND POWER -LIMITED UNLESS OTHERWISE INDICATED. SHIELD WIRES ARE NOT SUPERVISED. • MOST SHORTS ARE SHIELD TO CONDUCTOR. T-TAPPED. IT MUST BE 10. OPERATING POWER, FOR IDNet DEVICES, MUST ORIGINATE FROM A POWER -LIMITED POWER SUPPLY LISTED FOR FIRE PROTECTIVE SIGNALING USE • BY CREATING A PROPER PROCEDURE FOR WIRE DONE IN A JUNCTION OR, FROM THE F.A. CONTROL PANEL POWER SUPPLIES INDICATED IN THE APPROPRIATE DIAGRAM. MAXIMUM WIRE NOT TO EXCEED 1 KM (3270 FT). HANDLING WITH ADDRESSABLE CIRCUITS MOST BOX WITH CABLE 11. WHEN COMMUNICATION WIRING OR OPERATING WIRING LEAVES THE BUILDING, OVER -VOLTAGE PROTECTORS ARE REQUIRED; USE 2081-9044, INSTALL GROUNDS AND SHORTS CAN BE ELIMINATED. STRAIN RELIEF I.E. ONE WHERE IT LEAVES THE BUILDING AND ONE WHERE IT ENTERS THE NEXT BUILDING. • ALL UNSHIELDED WIRE MUST BE ENTIRELY IN CORD CLAMP/BUSHINC 12. TO PREVENT CONFUSION AND POSSIBLE ERRORS, TAG ALL CONDUCTORS, CODE AT INSTALLATION, TO IDENTIFY CIRCUIT ASSIGNMENT, POLARITY AND GROUND CONDUIT. AND TAPE WRAPPED P IN OR OUT DIRECTION OF THE WIRING. LOG ON AS-BUILTS. • CONDUIT SYSTEM MUST HAVE A GOOD SHOWN HERE. 13, LEAVE ADEQUATE SLACK IN THE WIRING TO ALLOW FOR TROUBLE SHOOTING. SIMPLEXGRINNELL IS NOT RESPONSIBLE FOR ELECTRICAL REFERENCE TO EARTH GROUND CONTRACTOR'S WIRE CONDITIONS. • PIGTAILS, (T-TAP) WIRING IS PERMITTED TO 14. IDNet COMMUNICATION LINE SPECS.: MAX. 36 VDC @ .5A 3333 BAUD 33 0 MAX. LINE RESISTANCE ADDRESSABLE DEVICES FOR CLASS B CIRCUIT 15. IDNet MAXIMUM NUMBER OF DEVICES: NON -CODED 250 CODED PIEZO BASES 43 MAX. 217 ADDRESSES STILL AVAILABLE FOR OTHER DEVICES. WIRING. CURTIS ENGINEERING SERVICE, LLC - CA#31561 JAMES M. CURTIS, P.E. - PE#37912 29775 BAYHEAD ROAD DADE CITY, FLORIDA 33523 SUCCESSOR ENGINEER OF RECORD This item been electronically signed and seated by James Curtis,Y.E.,ra digital jtyt Digitally signed ri si at right: by James Curtis No.37912 `q -� 8 Date: STA*M OF �` 2021.-- notnco;Rla A nod sealed,re 10:18:19-05'00' the signature must be verified on any electronic copies. -� H C O tA O � C C L V O Coco �� to rn MM 0000 L0 Cq ui wz Ok U)aLL d 0 ry w U toCj N N coco cO NwcMMr- >_JM F- ZLLw U �QU o � > � or1r w V♦ J U Q Uj C- N Jlie r Ln J � M Q W LJ-1 N > w O ■ ~0 Q0J Z co W m J ZO _ Q0® W > to Ll.l QtiN z O f- a U Cn W 0 Y 2 U Q U LLt F- Q U � O J w Y =) w Q DRAWN BY: CHAITANYA GODBOLE CHECKED BY: JACK JECKEL_ ISSUE DATE: 12/23/21 JOB #: PROJECT #: 292:650110515 JOHNSON CONTROLS 0 2021 SYSTEM: FIRE ALARM SYSTEM SHEET: WIRING TYPICALS FA-701