HomeMy WebLinkAbout22-37415335 Eighth Street Zephyrhills, FL 33542 ,*,-,hone: (813) 780-0020 Fax: (813) 780-0021 lid INI EMIRWAIIIIIIIA MIRMIMARNI LIN M I II Rl FIRE-00374 Issue Date: 03/ accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTL SIGNATURE PERMIT EXPIRES IN 6 MONTHS CALLFO PE IT OFFICE NITHOUT APPROVED INSPECTION SPRINKLER LEGEND SYMBOL COUNT I K—FACTOR I SIN III DESCRIPTION EXISTING PENDANT TO REMAIN C 9 5.6 RA1414 NEW LOCATION OF RELAOCATED RELIABLE F1 FR WHITE PENDANT SPRINKLER 155' 14 5.6 RA1414 NEW RELIABLE F1FR WHITE PENDANT SPRINKLER 155- TO BE INSTALLED EXISTING PENDANT TO BE RELOCATED DENOTES EXISTING FIRE SPRINKLER PIPE TO BE DEMO — — — — — — — — — — — — — — — — — — — — — — — DENOTES EXISTING FIRE SPRINKLER PIPE TO REMAIN DENOTES NEW FIRE SPRINKLER PIPE �— DENOTES CONNECTION POINT TO EXISTING FIRE SPRINKLER SYSTEM FIRE SPRINKLER MEZZANINE REMODEL PLAN SCALE: $' = 1'-o" 9 19 i N. FIRE SPRINKLER FIRST FLOOR REMOD SCALE:.', = 1'-o" H VE.. ` ... 1 F ^ k r im[z J1 MllN4NLr_m rULL I-1ICVrl 1 V1"[U%D0 JCIa I IUIV SCALE: NTS EL PLAN Ny f y SCOPE OF WORK: TO DESIGN AND RETROFIT THE FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA 13, 2016, FLORIDA FIRE PREVENTION CODE 7TH EDITION AND LOCAL AUTHORITY. BUILDING HAS AN OPERATIONAL FIRE SPRINKLER SYSTEM. WORK CONSIST OF RELOCATION EXISTING SPRINKLERS TO NEW ROOM LAYOUT, AS SHOWN ON PLANS. AREA OF WORK APPROXIMATELY 18,000 SQ. FT. 1. ALL UNDERGROUND PIPING IS EXISTING TO REMAIN AS IS UNDISTURBED. 2. ALL 1" TO 2" PIPING TO BE BLACK SCHEDULE 40 THREADED AND JOINED BY DUCTILE IRON FITTINGS AND COUPLINGS. 3. ALL 22" TO 6"' PIPING TO BE BLACK SCHEDULE 10 ROLL GROOVED AND JOINED BY GROOVE TYPE FITTINGS. 4. ALL HANGERS AND TRAPEZE ASSEMBLIES SHALL UTILIZE UL/FM LISTED COMPONENTS AND COMPLY WITH NFPA 13 REQUIREMENTS. 5. ALL CONTROL VALVES ARE EXISTING TO REMAIN AS IS UNDISTURBED. 6. ALL NEW INTERIOR PIPING SHALL BE HYDROSTATICALLY TESTED AS REQUIRED BY NFPA 13 SECTION 24.2.1. 7. INSTALL PENDANT SPRINKLER HEADS IN CENTER OF THE CEILING TILE. 8. A STOCK OF SPARE SPRINKLER HEADS SHALL BE PROVIDED IN ACCORDANCE WITH NFPA 13. 9. MIC (MICRO -BIOLOGICALLY INFLUENCED CORROSION) IS NOT KNOWN TO BE A PROBLEM AT THIS LOCATION. 10. MODIFICATIONS DO NOT INCREASE THE HYDRAULIC DEMAND OF THE EXISTING SYSTEM, NO HYDRAULIC CALCULATIONS ARE INCLUDED. HATCH DENOTES AREA OF WORK a N 3 � CL on A Jcn � W 0 1-4 0 W O W pGUUL. EXISTING RISER LOCATION FIRE SPRINKLER KEY PLAN SCALE: NITS SEE FLOOR PLAN FOR ARM -OVER LENGTHS ARM -OVER / RETURN BEND DETAIL STEEL BAR JOIST OR BEAM CAD PLATED FERROUS ALL —THREAD ROD SEE MINIMUM SIZE NOTE: BULK HANGER MATERIAL HAS BEEN SENT TO THE JOBSITE. FIELD CUT HANGERS AS NECESSARY. milzm9mmuld . ALL THREAD ROD SIZES PIPE SIZES 1" — 4" -- ROD SIZE = 3/8" PIPE SIZES 5" — 8" -- ROD SIZE = 1/2" BASIC PIPE AND FITTING MATERIAL REQUIREMENTS: MINIMUM PIPE SCHEDULE FOR WELD/GROOVED/PLAIN MISCELLANEOUS MATERIAL REQUIREMENTS: END PIPING: ❑ SCH. 7 (DYNAFLOW, ETC.) [BLACK STEEL PIPE ❑ DOMESTIC MATERIAL ONLY 2'SCH. 10 ❑ GALVANIZED PIPE [?'DOMESTIC OR FOREIGN MATERIAL ACCEPTABLE ❑ SCH. 40 ❑ "SEAMLESS" [MATERIAL TO MEET THE MINIMUM REQUIREMENTS OF NFPA 13 ❑ SCH. 80 ❑ SHOP PAINTED [MATERIAL TO BE UL LISTED AT A MINIMUM ❑ CPVC ❑ MATERIAL TO BE UL LISTED & FM APPROVED ❑ DRAIN PIPE & FITTINGS TO BE "GALVANIZED" MINIMUM PIPE SCHEDULE FOR THREADED PIPING: ❑ GALVANIZED PIPE & FITTINGS REQUIRED FOR EXTERIOR WALL PENETRATIONS & EXTERIOR PIPING RUNS. ❑ "THREADABLE" LIGHTWALL [BLACK STEEL PIPE HANGER MATERIAL [SCH. 40 ❑ GALVANIZED PIPE ❑ SCH. 80 ❑ "SEAMLESS" [STANDARD LOOP HANGER RINGS ❑ ___ ❑ SHOP PAINTED ❑ CLEVIS HANGERS REQUIRED ❑ ALL THREAD ROD TO 'BLACK' FeALL THREAD ROD TO BE 'CAD PLATED' FITTINGS UTILIZED ON THIS PROJECT: ❑ "STAINLESS" HANGER MATERIAL REQUIRED ❑ GROOVED (STANDARD TAKEOUT) ❑ C.I. SCREWED ❑ GROOVED (SHORT RADIUS) E�D.I. SCREWED ❑ GROOVED COUPLINGS (RIGID) ❑ M.I. SCREWED (BLK) ❑ GROOVED COUPLINGS (FLEXIBLE) ❑ M.I. SCREWED (GALV) ❑ WELDED OUTLETS ❑ FLANGED 125# Fj(MECHANICAL TEES ❑ FLANGED 250# ❑ CPVC O Q� W M M 4< ♦ ) L O Q\ J 0Qry Q 000 LL Q � J = z J Q0= JV� n O W qt N 0 E 0 c 0 No. Revision/Issue Date i.i �Am A i v� v Comm ercial FIRE & Comm unlca dons, Inc. P.O. BOX 1350 FPC19-000011 LARGO, FL. 33779 EF20001347 (727) 530-4521 PH. (727) 531-0596 FAX Engineering@cfcsystems.com Sheet Title: SITE PLAN Project Number. SJS1067 Date: 2/18/22 Scale: AS -NOTED Sheet #: FP-1 1 of 1