Loading...
HomeMy WebLinkAbout22-3870City of Zephyrhills 5335 Eighth Street Zephyrhills, FL 33542 FIRE-003870-2022 Phone: (813) 780-0020 Fax: (813) 780-0021 Issue Date: 04/12/2022 02 26 21 0010 00900 0020 Name: HOME THEATRE OF ZEPHYRHILLc Permit Type: Fire INC Class of Work: Sprinkler System Address: 6848 Gall Blvd Building Valuation: $4,283.00 ZEPHYRHILLS, FL 33542 Phone: (813) 782-2222 Electrical Valuation: Mechanical Valuation: Plumbing Valuation: Total Valuation: $4,283.00 Total Fees: $145.00 Amount Paid: $145.00 Date Paid: 4/12/2022 3:41:37PM 6848 Gall Boulevard Contractor: INTERNATIONAL FIRE PROTECTION INC REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. Mr-M-T771111, M-1 =1= Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNATURE PE IT OFFICE() PERMIT EXPIRES 111,'6 41011THS WITHOUT APPROVED INSPECTIO1 CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER SLOPED CEILING ACOUSTICAL GRID P NOTE: ALL CIL ING HEIGHTS ARE SHOWN ON THE PLAN SYMBOL DESCRIPTION QTY. (Relocate RELOCATE FIRE SPRINKLER HEAD ---- Q� EXISTING PENDENT HEAD TO BE REMOVED 4 EXISTING PENDENT HEAD TO REMAIN - RASCO R1015 K5.6 G PENDENT 5 • �a NEW PENDENT SPRINKLER HEAD - RASCO R1015 K5.6 G PENDENT 4 o gf* ELEVATION'SYMBOL FOR PIPE AND SPRINKLER HEADS ABOVE FINISHED FLOOR ---- ------------ EXISTING FIRE SPRINKLER PIPING (DASH LINES) NEW FIRE SPRINKLER PIPING (SOLID LINES) NOTE. - THE NUMBER OF SPRINKLER HEADS SHOWN ON THIS TABLE IS FOR THE SCOPE OF WORK AREA ONLY EXISTING FIRE SPRINKLER PLAN SCALE: 1/8" = 1 FOOT ZEE-PURLIN CLAMP W! SWIVEL .t Z - PURLIN PURLIN CLAMP ALLTHREAD ROD SWIVEL RING k t, -� - - PIPE SCALE: NOT TO SCALE RETURN BEND DETAIL SPRINKLER WI 4401 ESC 1"ARMOVER 1" ELBOW J --- a 1" ELBOW 1" RISER �----1" SCHAO DROP BRANCHLINE 2'-0" CEILING SEE PLAN FOR HEIGHT If 1" X 1/2" R.C. I -401 ESCUTCHEN PENDENT SPRINKLER SCALE: NOT TO SCALE U • -V•- - ) RELOCATE APPROXIMATELY 7 FIRE SPRINKLER HEADS THROUGHOUTTHE EXISTING LOBBYAREATOAN EXISTING WET FIRE SPRINKLER SYSTEM. 4 SPRINKLER HEADS THAT WILL NO LONGER BE NEEDED d ERAL NOTES EM DESIGN, INSTALLATION AND TESTING SHALL BE IN ACCORDANCE WITH NFPA 13 (2016 EDITION), NFPA 101 (2018 EDITION), NFPA 1 (2018 EDITION), )RIDA FIRE PREVENTION CODE (7TH EDITION). ATERIALAND DEVICES TO BE U_L. LISTED AND/OR F.M. APPROVED FOR FIRE SPRINKLER USE. 'SYSTEM PIPING SHALL BE SCHEDULE 40 BLACK PIPE. ANGERS SHALL BE DESIGNED, SPACED AND INSTALLEDAS PER NFPA 13 (2016 EDITION). RE DIMENSIONS ARE (cut)_ PRINKLER HEADS AND PIPE ELEVATIONS ARE SHOWN. NUM SPACING FOR PENDENTAND UPRIGHT SPRINKLERS TO BE 19. NUM AREA OF COVERAGE FOR PENDENT SPRINKLERS TO BE 225 SQ.FT. IUM DISTANCE BETWEEN UPRIGHTAND PENDENT SPRINKLER HEADS SHALL BE 6-0. SS MAIN AND BRANCH LINE ELEVATION ARE 14'-0"A.F.F. NS WITH WET SPRINKLER PIPING TEMPERATURE IS TO BE MAINTAINED ABOVE 40 DEGREES (OWNER RESPONSIBILITIES). IT HAZARD CLASSIFICATION FOR THE BATHROOMS AND LOBBYAREA. 'HEDAREA NOT IN SCOPE OF WORK. DTHER EXISTING AREAS ARE FULLY SPRINKLERED THROUGH OUTTHE BUILDING DONE BY OTHERS. KEY PLAN u 0 z, z M C 0014 Z .+ L 00Lu r ry d' a LL 00 N a w Y O } H �z N a p O N F w w m w U O z p w Z p z H w ? O �-I--OPOWRX OOz z 0 0 w N tab H z ui > C3 z z 0 0 w w w I tlJ Z w O m J � Q r z J J U Q Ja Q i U U. w LL U J _i ��- O p U 1- z Q z Q O n Q [Q U U U C� C7 C9 Q Ci U u> J O O Q fO U U U t9 C9 (9 W J H F- J N O C '- maa � O 0 N U Ca�"v0 c a. accss 0 av -� 26cE u- Q�O� °� E a� m wzcvc�- 0 E- Z ccU me off- p•�F� E U i- 0-0 � c0 0— a 0 N C 0 Ua 0-wi✓ d O ui ie <6 2 fl. C ui C C 15 N C O S LL V N Z L N a C� Cu C O¢ O N O N MiBz d 0 ao 3 3CL 0 Q N'OF- U' 0— mww Z sll z a. s r- •- 0 u, 0 3 Z O u m LLJ L J J Z QQQaQQa co a Z DRAWN BY: KZ DATE: 3/16/2022 z SCALE: as noted t? 0 o z � a V a Jcif) W _ �J Y z 2 M IL w J- W d„ .L LL 0i z CD CL a W = N Cn •w J_ m o W N W w ¢ z ¢. z F- w m 0 w = W CONTRACT NUMBER Q a O SHEET NUMBER . a FP-1