GENERAL NOTES
1. THE FIRE ALARM SYSTEM DESIGN, INSTALLATION AND ALL MATERIALS SHALL BE IN
ACCORDANCE WITH NFPA 70 & 72. THE SYSTEM SHALL ALSO MEET ALL APPLICABLE
BUILDING CODES FIRE CODES AND ND THE REQUIREMENTS OF THE LOCAL AUTHORITY
HAVING JURISDICTION.
2. LOCATION AND PLACEMENT OF THE FIRE ALARM DEVICES ARE NOT TO BE
CONSIDERED DIAGRAMMATIC IN NATURE. ANY CHANGE IN THE LOCATION OR
PLACEMENT OF BOTH DETECTION AND NOTIFICATION DEVICES MUST BE REVIEWED
AND APPROVED BY THE E.O.R. FINAL APPROVAL OF DEVICE PLACEMENT IS SUBJECT
TO FIELD VERIFICATION FOR CODE COMPLIANCE.
3. THE SMOKE DETECTORS SHALL NOT BE PLACED WITHIN 36" IN FRONT OF THE
DISCHARGE OF THE VENTILATION DUCTS OR WITHIN 36" OF HOLES IN WALLS OR
CEILINGS UNLESS PART OF THE AIR RETURN SYSTEM.
4. HEAT DETECTORS SHALL BE USED IN AREAS WHERE THE ENVIRONMENT OR AMBIENT
CONDITIONS EXCEED SMOKE DETECTORS INSTALLATION GUIDELINES. IN AREAS
CONTAINING SPRINKLERS, HEAT DETECTORS MAY NOT BE REQUIRED.
5. ALL FIRE STROBES WHERE TWO OR MORE OR FLASHES FROM TWO OR MORE ARE
VISIBLE FROM ANY POINT, MUST BE SYNCHRONIZED UNLESS SEPARATED BY A
MINIMUM DISTANCE OF 55 FEET. WIRING AND HARDWARE CONFIGURATION FOR FIRE
STROBES IN A COMMON SPACE MUST BE PERFORMED CAREFULLY SINCE FEEDING
STROBES FROM DIFFERENT CIRCUITS OF DIFFERENT REMOTE POWER SUPPLIES OR
SYNC MODULES MAY CAUSE A CONDITION WHERE WITHIN THE SAME SPACE
SYNCHRONIZATION IS LOST DUE TO DIFFERENT POWER SOURCES AND
SYNCHRONIZATION TIMING. THE TRIGGER CIRCUIT FOR AUDIBLE SIGNALS SHOULD BE
FROM THE FACP TO INSURE SYNCHRONIZATION. ALL AUDIBLE SIGNALS MUST BE
SYNCHRONIZED WITH THE SAME NOTIFICATION ZONE.
6. PIPER FIRE PROTECTION SHALL MOUNT ALL FIRE ALARM VISUAL STROBE STATIONS TO
THE CODE COMPLIANT MOUNTING HEIGHT OF 80"-96" TO BOTTOM OF LENS.
7. PANELS MUST BE MOUNTED HIGHER THAN 6 FEET AND SYSTEM STATUS DISPLAYS ARE
TO BE EYE LEVEL F 60 A F . NO EQUIPMENT OR RACEWAY MAY BE LOCATED UNDER A
CABINET CONTAINING BATTERIES.
8. THE AUTOMATIC FIRE ALARM SYSTEM SHALL TRANSMIT THE ALARM, SUPERVISORY
AND TROUBLE SIGNALS TO AN APPROVED SUPERVISING STATION AS REQUIRED BY
NFPA 72. THE FACP SHALL REPORT CONTACT ID TO MONITORING AND 911. (WHERE
APPLICABLE)
9. ALL AIR HANDLER UNITS, AND EXHAUST FANS SHALL SHUTDOWN UPON ACTIVATION OF
NEW FIRE ALARM SYSTEM.
10. ALL MAGNETIC DOOR HOLDERS SHALL RELEASE UPON ACTIVATION OF NEW FIRE
ALARM SYSTEM.
11. INSTALL END -OF -LINE DEVICES AS REQUIRED TO MAINTAIN CIRCUIT SUPERVISION.
12, FIRE ALARM SYSTEM CONDUIT SHALL NOT BE USED FOR ANY OTHER WIRING.
13. SPLICING OF FIRE ALARM WIRING IS NOT ALLOWED. ALL TERMINATIONS SHALL BE MADE IN
TERMINAL CABINETS ON TERMINAL BLOCKS OR ON FIRE ALARM EQUIPMENT TERMINALS.
14. A LICENSED ELECTRICAL CONTRACTOR SHALL INSTALL A 120 VAC 20A DEDICATED
CIRCUIT(S) FOR EACH CIRCUIT FEEDING FIRE ALARM EQUIPMENT. CIRCUIT BREAKER AT
PANEL BOARD SHALL BE EQUIPPED WITH A HANDLE LOCK -ON DEVICE AND SHALL BE
IpENTIFIED AS "FIRE ALARM CONTROL CIRCUIT", CIRCUIT NUMBER, ELECTRICAL PANEL
NAME AND LOCATION SHALL BE PERMANENTLY AND CLEARLY MARKED ON THE INSIDE
SURFACE OF THE FIRE ALARM UNIT. ACCESS TO CIRCUIT BREAKER(S) SHALL BE RESTRICTED
TO AUTHORIZED PERSONNEL ONLY. PROVIDE SURGE SUPPRESSOR AT INPUT OF FIRE ALARM
UNIT.
15. ALL FIRE ALARM EQUIPMENT SHALL BE LISTED FOR FIRE SERVICE.
16. ALL WIRING AND CONDUIT TO CONFORM TO NFPA 72 AND NEC ARTICLE 760, 725 & 800.
WIRING SHALL BE SOLID COPPER OR STRANDED COPPER WITH A MAX. OF 7 STRANDS FOR 16
GA NAD 18 GA. STRANDED COPPER WITH A MAX. OF 19 STRANDS FOR SIZES 14 AND LARGER
PER NEC 760 AND NFPA 70.
17. ALL FIRE STOP PENETRATIONS SHALL BE MADE WITH APPROVED (NEC) METALLIC CONDUIT
AND SHALL BE SEALED WITH A U,L APPROVED FIRE STOP MATERIAL. (SEE FIRE STOP DETAIL)
18. ROUTING OF ALL FIRE ALARM CONDUIT AND WIRING IS DIAGRAMMATIC ONLY, VERIFY EXACT
REQUIREMENTS IN FIELD AND PROVIDE ACTUAL ROUTING ON AS -BUILT DRAWINGS.
19. ALL FIRE ALARM NOTIFICATION APPLIANCES SHALL ACTIVATE UPON INITIATION OF THE
GENERAL ALARM.
20. ALL FIRE ALARM NOTIFICATION APPLIANCES SHALL HAVE A SOUND LEVEL OF AT LEAST 15
dba ABOVE THE AVERAGE AMBIENT SOUND LEVEL.
21. MANUAL PULL STATIONS SHALL BE INSTALLED AT 48" INCHES A.F.F.
22. MOUNT AUDIBLE/VISUAL SIGNALS (COMBINATION DEVICES) SUCH THAT THE ENTIRE STROBE
LENS IS 80" A,F.F. OR 6" BELOW! CEILING, WHICHEVER IS LOWER.
23. A GENERAL ALARM SHf1LL BE ANNUNCIATED UPON ACTIVATION OF ANY PULL STATION, FLOW
SWITCH OR DETECTION DEVICE.
24. A TROUBLE SIGNAL SHALL BE ANNUNCIATED UPON FAILURE OR REMOVAL OF ANY DETECTION
OR MANUAL DEVICE,
25. A SUPERVISORY SIGNAL SHALL BE ANNUNCIATED UPON ACTIVATION OF ANY FIRE SPRINKLER
SYSTEM TAMPER SWITCH.
26. HVAC DUCT SMOKE DETECTORS SHALL BE CONNECTED TO THE FIRE ALARM CONTROL PANEL
AND SHALL INITIATE A SUPERVISORY SIGNAL ONLY.
27. ALL FIRE ALARM INITIATING DEVICES SHALL BE ADDRESSABLE AND ALL FIRE ALARM
CIRCUITS SHALL BE CLASS "B".
28. THE FIRE ALARM CONTRACTOR SHALL COORDINATE WITH THE MECHANICAL CONTRACTOR TO
PROVIDE ADDRESSABLE DUCT SMOKE DETECTORS WITH SERVICE ACCESS DOORS IN ALL
SUPPLY AIR DUCTS FOR FANS AND AHU'S SERVING A COMMON PLENUM OF 2000 CF1`1 OR
ABOVE.
29. ALL DOORS EQUIPPED WITH ANY ACCESS CONTROL HARDWARE OR DELAYED EGRESS
HARDWARE SHALL RELEASE UPON ALARM ACTIVATION.
30. NOT ALL SYMBOLS, NOTES AND ABBREVIATIONS LISTED HEREIN APPLY TO THIS
PROJECT. REFER TO THE CONSTRUCTION DOCUMENTS FOR SYMBOLS APPLICABLE TO
THIS SCOPE OF WORK.
31. FIRE ALARM DESIGN IS IN ACCORDANCE WITH FLORIDA STATUTES CHAPTER 61 G15-32.
WHERE A FIRE ALARM RISER IS INDICATED, IT IS DIAGRAMMATIC IN NATURE AND NOT
INTENDED TO REPRESENT A COMPLETE WIRING AND DEVICE DISPLAY.
REFER TO FLOOR PLANS FOR DESIGN INTENT AND PROPOSED QUANTITY OF THE
FIRE ALARM SYSTEM COMPONENTS.
PROJECT SCOPE
1. PROVIDE NEW FIRE ALARM CELLULAR DIALER FOR AN EXISTING MONITORED
FIRE ALARM SYSTEM.
2. PIPER FIRE PROTECTION WAS NOT THE ORIGINAL FIRE ALARM SYSTEM INSTALLER,
THEREFORE FULL SYSTEM BATTERY CALCULATIONS ARE NOT AVAILABLE AT TIME
OF PERMITTING.
3. THE NEW CELLULAR DIALER INCLUDES ITS OWN POWER SUPPLY, AND DOES NOT
REQUIRE ANY AMPERAGE LOAD FROM THE EXISTING FIRE ALARM CONTROL PANEL TO
OPERATE.
4. THE EXISTING FIRE ALARM SYSTEM SHALL TRANSMIT THE ALARM, SUPERVISORY
AND TROUBLE EVENTS TO AN APPROVED SUPERVISING STATION ( AND 911) AS REQUIRED
BY NFPA 72.
5. PIPER FIRE PROTECTION WILL INSTALL, PROGRAM, TEST AND INSPECT ALL
PROVIDED AND INSTALLED FIRE ALARM DEVICES REQUIRED BY CODE, THE NEW
SYSTEM IS REQUIRED TO COMPLY WITH (FLORIDA FIRE PREVENTION CODE 7TH
EDITION)
6. CONDUCT A FINAL ACCEPTANCE TEST OF THE FIRE ALARM SYSTEM AND ALL FIRE
ALARM COMPONENTS RELATED TO THE PROJEO-FS AREA OF `NORK. FINAL
ACCEPTANCE MUST BE WITNESSED BY THE AUTHORITY HAVING JURISDICTION.
FLORIDA FIRE PREVENTION CODE- 7TH EDITION
NFPA 101, THE LIFE SAFETY CODE, 2018 EDITION
NFPA 1, THE FIRE CODE (2018 EDITION)
NFPA 70, THE ELECTRIC CODE (2017 EDITION)
NFPA 72 THE FIRE CODE 2016 EDITION
PROJECT INTENT
1. OCCUPANCY: PROJECT SQ. FT:
2. SMOKE DETECTION:
FIRE PROTECTION SYSTEM:
NOTIFICATION APPLIANCES:
3. FIRE ALARM CIRCUITS:
3.1. SLC -
3.2. NAC -
3.3. 24 VDC POWER CIRCUITS -
3.4. PATHWAY SURVIVABILITY -
-__1 A -
SYSTEM OUTPUTS
CONTROL UNIT ANNUNCIATION NOTIFICATION
REQUIRED FIRE SAFETY CONTROL
o
= h
Q
Q U vJ
j
WO
�z
U
ti° QO e O 4� O°
r,° TT.
4-���"':..
ht(/ , �r(/ y P Q'„'
:• O n _x
'J
j W
°
4 2
W
Q
FIRE RESPONSE MATRIX:
z 3
z z z
o
r o Q 2 �� o z
z °
° o
�'
f��
x£°' =3?
,
GENERAL
l�
Q
0
ALARM
V U
o C5Q2 �� ��
(U J �b�j✓
Q U 'i U V
�� o
xuf 1 ,C 13
p� {� l� l� cr
J 0 �2
%
ti z z J
�� ru
h
t €V.,`. J
Yv�e
SYSTEM INPUTS A
B C D
E F C H I J K e� N �rp3
G R
5�U V W XgTy
Z
1 FIRE ALARM SYSTEM AC POWER FAILURE
• •
•F `:s
'�
"`'` 1
2
FIRE ALARM SYSTEM LOW BATTERY
-�.:.'-..
�' 6;
,fir<-
_'.q
,�
°a'i�t'�•
uR�
t�
w
4. _
£
z!
2
,�
J
OPEN CIRCUIT
I'-'
� 13.
�
�fi�tt.r�,�a'E
3E�1'rt`,t
�"�'•s �,
4, a
"�
b�;-
3
�
•,
4
GROUND FAULT
•
•
'
•''
h� 0,
5
NOTIFICATION APPLIANCE CIRCUIT SHORT I
��"
:
•
•`z
��^+-
y j?
•�1ohf
s '��'P,
�
�;S`"•I-
J4
knF
�' ��' S
'
6
e"F
BUILDING MANUAL PULL STATION
N
sN1oK_F D_r_croR F F •
F
�_Ar o_rF_croR w
•
�;�
!�
•
:.
•
r
,;,::d
J�
�
•
•
��
"�m�aa„�
e3��
5:�
"� sl f;x.,
,mraix
9
10
HVAC AIR DUCT SMOKE _ z` OR
t4
x.
'"
x:��:
..
4
11
HOOD OR ROOM FIRE SUPPRE
SYSTEM ALARM s8' , +
�`
•
•
•
•
•
•
nq
•
•ra3�
. .
<,,a�t.,
e 1i2�.,
12
SPRINKLER SYSTEM TAPAPER S'Pll
•
�a.
l
12
SPRINKLER SYSTEM FLOW SWITCH`„
IN BUILDING
,,✓
� ,,
u
••
l �13
J
14
I`
SPRINKLER SYSTEM FLOP/ SWITCH �"� " •„
IN ELEVATOR EQUIP RNI OR SHAFT I
11
•
i
i
�
, __
•
m�.�1.A,
Y-.,
•
•
�
# �°
• •
•,
`°': "��
14
FIRE ALARM SEQUENCE NOTES
General Fire Alarm System Sequence of Operation
1 'N Alar tem SHALL operate as follows:
1.1 Manual 0 on- operation of a manual free alarm pull station shall:
1.1.A. I A the individual station on the system cor.�s1 panel and s1
€roi _control panel and remote alarm panels
a t down ventilationsystems.gh
a,' a 1
Sound audible alarms and actuatekE;r )cation
1A.D. Transmit a signal to the central sta> i,"1 ,. ,
1.1.E. Activate the printer. "i
2.1 ctivation of a
HALL cause
2.Provideo
2.1 ' A signal d
nced
3.1 ctiva f ar
t
3.1.R Dis; h
disp
Activa"
remote= riunciator panels.
3.' Record the occurrente of the event, the time of occurrence and the device initiating
the event.
4.1 Receipt of a trouble signal at the fire alarm control panel SHALL cause the following
actions and indications:
4.1.A. Display at the control panel and remote annunciator panels alphanumeric LCD
display, the origin of the trouble condition report.
4.1.8. Activate trouble audible and visual signals at the fire control panel and remote
annunciator.
4.1.C. Record the occurrence of the event, the time of occurrence and the device initiating
the event.
ELL
MM
FAC -
333 Bay&w Avenue Amka Nov York 11701
FarTan
Q d)�+,;,aa StarLink SLE-LTEV-CFB-PS Fire Alarm Communicator
ota Technkc�,av%� ar near o boob on
M �a r)
PublWy lroded an NASDAQ SKnbd; NSSC Standby Battery C a l c u l a _ion s
? NAPCO 2019 WI2335LF 4/19
Standby Current Calculations for the model SLE-LTEV-CFB-PS Fire Alarm
Communicator:
Stondbv Battery Caoocitv:...................................... 24 AH
FIRE ALARM SYSTEM SYMBOL LEGEND
QTY: SYMBOL
DESCRIPTION:
MOUNTING:
ELEVATION:
PART NUMBER:
EX
AC
FIRE ALARM CONTROL PANEL
EXISTING
EXISTING
MS-905OUD
1
ELL
CELLULAR DIALER
OWN CABINET
VERIFY IN FIELD
SLE-LTEV-CFB-PS
1
n
Mini Module
JBOX
VERIFY IN FIELD
MMF-301
FIRE ALARM SYSTEM WIRE LEGEND
NOT ALL WIRE TYPES WILL BE USED FOR EVERY PROJECT
YS MBOL IC RCUIT COLOR SCHEME AWG-CONDUCTORS WINDY CITY PART NUMBER
A
SLC Circuit
18G-2C FPLP
762369 (Red w/ White Stripe FPLP)
B
NAC Circuit
14G-2C FPLP
7679610 (Black FPLP)
" ' '
C
Voice Circuit
16G-2C FPLP
761362 (Red w/ Blue Stripe FPLP)
D
VBUS Circuit
"' "''
16G-2C FPLP
761366 (Red w/ Green Stripe FPLP)
F
Annunciator SBUS
s . _ Jrlr.,
18G-4C FPLP
762380 Red FPLP
( )
G
NAC Trip
Y f .t `'
18G-2C FPLP
762361 (Red w/ Black Stripe FPLP)
H
Auxiliary Circuit
" I I
16G-2C FPLP
761363 (Red w/ Yellow Stripe FPLP)
Sta,Lin <l" SLe SERIES COMMUNICATORS
e e Tc•:"fEtY-
i lath 10V=91nA u.•=71O,A_
N.�411.„.'r�ll.1 LLL.J iDe iiVJ2 3_L O 1 5 L-O:'r�
REFER TO INSTALLATION INSTRUCTIONS W11653
r
764
NX
10
AX
I
II
�I rJ :ilr F