Loading...
HomeMy WebLinkAbout22-4680�1ledtr�Yi^\itta�'�?N?'4ZSc`li _ti2klt t City o hi r Uniform Notice of Low-`Vo to e Alarm System Project Owner's/Custosner�N°ame G2 C Address 50I Z City f St Zip 3,5 2- Phone E-mail contractor n +c, { ity e r St Zip a �a *hone : t ° � a DateProjectComplete ope�oof Work: K + 6 LT t � l e' JJ�a- leas i�nature. Ouner or tenant or contractor or authorized representative Notice is hereby given that a low -voltage alarm system project has been completed at the address specified above. I certify that all of the foregoing information is true and accurate. 1011113 section 553.793 FS GENERAL NOTES 1. THE FIRE ALARM SYSTEM DESIGN, INSTALLATION AND ALL MATERIALS SHALL BE IN ACCORDANCE WITH NFPA 70 & 72. THE SYSTEM SHALL ALSO MEET ALL APPLICABLE BUILDING CODES FIRE CODES AND ND THE REQUIREMENTS OF THE LOCAL AUTHORITY HAVING JURISDICTION. 2. LOCATION AND PLACEMENT OF THE FIRE ALARM DEVICES ARE NOT TO BE CONSIDERED DIAGRAMMATIC IN NATURE. ANY CHANGE IN THE LOCATION OR PLACEMENT OF BOTH DETECTION AND NOTIFICATION DEVICES MUST BE REVIEWED AND APPROVED BY THE E.O.R. FINAL APPROVAL OF DEVICE PLACEMENT IS SUBJECT TO FIELD VERIFICATION FOR CODE COMPLIANCE. 3. THE SMOKE DETECTORS SHALL NOT BE PLACED WITHIN 36" IN FRONT OF THE DISCHARGE OF THE VENTILATION DUCTS OR WITHIN 36" OF HOLES IN WALLS OR CEILINGS UNLESS PART OF THE AIR RETURN SYSTEM. 4. HEAT DETECTORS SHALL BE USED IN AREAS WHERE THE ENVIRONMENT OR AMBIENT CONDITIONS EXCEED SMOKE DETECTORS INSTALLATION GUIDELINES. IN AREAS CONTAINING SPRINKLERS, HEAT DETECTORS MAY NOT BE REQUIRED. 5. ALL FIRE STROBES WHERE TWO OR MORE OR FLASHES FROM TWO OR MORE ARE VISIBLE FROM ANY POINT, MUST BE SYNCHRONIZED UNLESS SEPARATED BY A MINIMUM DISTANCE OF 55 FEET. WIRING AND HARDWARE CONFIGURATION FOR FIRE STROBES IN A COMMON SPACE MUST BE PERFORMED CAREFULLY SINCE FEEDING STROBES FROM DIFFERENT CIRCUITS OF DIFFERENT REMOTE POWER SUPPLIES OR SYNC MODULES MAY CAUSE A CONDITION WHERE WITHIN THE SAME SPACE SYNCHRONIZATION IS LOST DUE TO DIFFERENT POWER SOURCES AND SYNCHRONIZATION TIMING. THE TRIGGER CIRCUIT FOR AUDIBLE SIGNALS SHOULD BE FROM THE FACP TO INSURE SYNCHRONIZATION. ALL AUDIBLE SIGNALS MUST BE SYNCHRONIZED WITH THE SAME NOTIFICATION ZONE. 6. PIPER FIRE PROTECTION SHALL MOUNT ALL FIRE ALARM VISUAL STROBE STATIONS TO THE CODE COMPLIANT MOUNTING HEIGHT OF 80"-96" TO BOTTOM OF LENS. 7. PANELS MUST BE MOUNTED HIGHER THAN 6 FEET AND SYSTEM STATUS DISPLAYS ARE TO BE EYE LEVEL F 60 A F . NO EQUIPMENT OR RACEWAY MAY BE LOCATED UNDER A CABINET CONTAINING BATTERIES. 8. THE AUTOMATIC FIRE ALARM SYSTEM SHALL TRANSMIT THE ALARM, SUPERVISORY AND TROUBLE SIGNALS TO AN APPROVED SUPERVISING STATION AS REQUIRED BY NFPA 72. THE FACP SHALL REPORT CONTACT ID TO MONITORING AND 911. (WHERE APPLICABLE) 9. ALL AIR HANDLER UNITS, AND EXHAUST FANS SHALL SHUTDOWN UPON ACTIVATION OF NEW FIRE ALARM SYSTEM. 10. ALL MAGNETIC DOOR HOLDERS SHALL RELEASE UPON ACTIVATION OF NEW FIRE ALARM SYSTEM. 11. INSTALL END -OF -LINE DEVICES AS REQUIRED TO MAINTAIN CIRCUIT SUPERVISION. 12, FIRE ALARM SYSTEM CONDUIT SHALL NOT BE USED FOR ANY OTHER WIRING. 13. SPLICING OF FIRE ALARM WIRING IS NOT ALLOWED. ALL TERMINATIONS SHALL BE MADE IN TERMINAL CABINETS ON TERMINAL BLOCKS OR ON FIRE ALARM EQUIPMENT TERMINALS. 14. A LICENSED ELECTRICAL CONTRACTOR SHALL INSTALL A 120 VAC 20A DEDICATED CIRCUIT(S) FOR EACH CIRCUIT FEEDING FIRE ALARM EQUIPMENT. CIRCUIT BREAKER AT PANEL BOARD SHALL BE EQUIPPED WITH A HANDLE LOCK -ON DEVICE AND SHALL BE IpENTIFIED AS "FIRE ALARM CONTROL CIRCUIT", CIRCUIT NUMBER, ELECTRICAL PANEL NAME AND LOCATION SHALL BE PERMANENTLY AND CLEARLY MARKED ON THE INSIDE SURFACE OF THE FIRE ALARM UNIT. ACCESS TO CIRCUIT BREAKER(S) SHALL BE RESTRICTED TO AUTHORIZED PERSONNEL ONLY. PROVIDE SURGE SUPPRESSOR AT INPUT OF FIRE ALARM UNIT. 15. ALL FIRE ALARM EQUIPMENT SHALL BE LISTED FOR FIRE SERVICE. 16. ALL WIRING AND CONDUIT TO CONFORM TO NFPA 72 AND NEC ARTICLE 760, 725 & 800. WIRING SHALL BE SOLID COPPER OR STRANDED COPPER WITH A MAX. OF 7 STRANDS FOR 16 GA NAD 18 GA. STRANDED COPPER WITH A MAX. OF 19 STRANDS FOR SIZES 14 AND LARGER PER NEC 760 AND NFPA 70. 17. ALL FIRE STOP PENETRATIONS SHALL BE MADE WITH APPROVED (NEC) METALLIC CONDUIT AND SHALL BE SEALED WITH A U,L APPROVED FIRE STOP MATERIAL. (SEE FIRE STOP DETAIL) 18. ROUTING OF ALL FIRE ALARM CONDUIT AND WIRING IS DIAGRAMMATIC ONLY, VERIFY EXACT REQUIREMENTS IN FIELD AND PROVIDE ACTUAL ROUTING ON AS -BUILT DRAWINGS. 19. ALL FIRE ALARM NOTIFICATION APPLIANCES SHALL ACTIVATE UPON INITIATION OF THE GENERAL ALARM. 20. ALL FIRE ALARM NOTIFICATION APPLIANCES SHALL HAVE A SOUND LEVEL OF AT LEAST 15 dba ABOVE THE AVERAGE AMBIENT SOUND LEVEL. 21. MANUAL PULL STATIONS SHALL BE INSTALLED AT 48" INCHES A.F.F. 22. MOUNT AUDIBLE/VISUAL SIGNALS (COMBINATION DEVICES) SUCH THAT THE ENTIRE STROBE LENS IS 80" A,F.F. OR 6" BELOW! CEILING, WHICHEVER IS LOWER. 23. A GENERAL ALARM SHf1LL BE ANNUNCIATED UPON ACTIVATION OF ANY PULL STATION, FLOW SWITCH OR DETECTION DEVICE. 24. A TROUBLE SIGNAL SHALL BE ANNUNCIATED UPON FAILURE OR REMOVAL OF ANY DETECTION OR MANUAL DEVICE, 25. A SUPERVISORY SIGNAL SHALL BE ANNUNCIATED UPON ACTIVATION OF ANY FIRE SPRINKLER SYSTEM TAMPER SWITCH. 26. HVAC DUCT SMOKE DETECTORS SHALL BE CONNECTED TO THE FIRE ALARM CONTROL PANEL AND SHALL INITIATE A SUPERVISORY SIGNAL ONLY. 27. ALL FIRE ALARM INITIATING DEVICES SHALL BE ADDRESSABLE AND ALL FIRE ALARM CIRCUITS SHALL BE CLASS "B". 28. THE FIRE ALARM CONTRACTOR SHALL COORDINATE WITH THE MECHANICAL CONTRACTOR TO PROVIDE ADDRESSABLE DUCT SMOKE DETECTORS WITH SERVICE ACCESS DOORS IN ALL SUPPLY AIR DUCTS FOR FANS AND AHU'S SERVING A COMMON PLENUM OF 2000 CF1`1 OR ABOVE. 29. ALL DOORS EQUIPPED WITH ANY ACCESS CONTROL HARDWARE OR DELAYED EGRESS HARDWARE SHALL RELEASE UPON ALARM ACTIVATION. 30. NOT ALL SYMBOLS, NOTES AND ABBREVIATIONS LISTED HEREIN APPLY TO THIS PROJECT. REFER TO THE CONSTRUCTION DOCUMENTS FOR SYMBOLS APPLICABLE TO THIS SCOPE OF WORK. 31. FIRE ALARM DESIGN IS IN ACCORDANCE WITH FLORIDA STATUTES CHAPTER 61 G15-32. WHERE A FIRE ALARM RISER IS INDICATED, IT IS DIAGRAMMATIC IN NATURE AND NOT INTENDED TO REPRESENT A COMPLETE WIRING AND DEVICE DISPLAY. REFER TO FLOOR PLANS FOR DESIGN INTENT AND PROPOSED QUANTITY OF THE FIRE ALARM SYSTEM COMPONENTS. PROJECT SCOPE 1. PROVIDE NEW FIRE ALARM CELLULAR DIALER FOR AN EXISTING MONITORED FIRE ALARM SYSTEM. 2. PIPER FIRE PROTECTION WAS NOT THE ORIGINAL FIRE ALARM SYSTEM INSTALLER, THEREFORE FULL SYSTEM BATTERY CALCULATIONS ARE NOT AVAILABLE AT TIME OF PERMITTING. 3. THE NEW CELLULAR DIALER INCLUDES ITS OWN POWER SUPPLY, AND DOES NOT REQUIRE ANY AMPERAGE LOAD FROM THE EXISTING FIRE ALARM CONTROL PANEL TO OPERATE. 4. THE EXISTING FIRE ALARM SYSTEM SHALL TRANSMIT THE ALARM, SUPERVISORY AND TROUBLE EVENTS TO AN APPROVED SUPERVISING STATION ( AND 911) AS REQUIRED BY NFPA 72. 5. PIPER FIRE PROTECTION WILL INSTALL, PROGRAM, TEST AND INSPECT ALL PROVIDED AND INSTALLED FIRE ALARM DEVICES REQUIRED BY CODE, THE NEW SYSTEM IS REQUIRED TO COMPLY WITH (FLORIDA FIRE PREVENTION CODE 7TH EDITION) 6. CONDUCT A FINAL ACCEPTANCE TEST OF THE FIRE ALARM SYSTEM AND ALL FIRE ALARM COMPONENTS RELATED TO THE PROJEO-FS AREA OF `NORK. FINAL ACCEPTANCE MUST BE WITNESSED BY THE AUTHORITY HAVING JURISDICTION. FLORIDA FIRE PREVENTION CODE- 7TH EDITION NFPA 101, THE LIFE SAFETY CODE, 2018 EDITION NFPA 1, THE FIRE CODE (2018 EDITION) NFPA 70, THE ELECTRIC CODE (2017 EDITION) NFPA 72 THE FIRE CODE 2016 EDITION PROJECT INTENT 1. OCCUPANCY: PROJECT SQ. FT: 2. SMOKE DETECTION: FIRE PROTECTION SYSTEM: NOTIFICATION APPLIANCES: 3. FIRE ALARM CIRCUITS: 3.1. SLC - 3.2. NAC - 3.3. 24 VDC POWER CIRCUITS - 3.4. PATHWAY SURVIVABILITY - -__1 A - SYSTEM OUTPUTS CONTROL UNIT ANNUNCIATION NOTIFICATION REQUIRED FIRE SAFETY CONTROL o = h Q Q U vJ j WO �z U ti° QO e O 4� O° r,° TT. 4-���"':.. ht(/ , �r(/ y P Q'„' :• O n _x 'J j W ° 4 2 W Q FIRE RESPONSE MATRIX: z 3 z z z o r o Q 2 �� o z z ° ° o �' f�� x£°' =3? , GENERAL l� Q 0 ALARM V U o C5Q2 �� �� (U J �b�j✓ Q U 'i U V �� o xuf 1 ,C 13 p� {� l� l� cr J 0 �2 % ti z z J �� ru h t €V.,`. J Yv�e SYSTEM INPUTS A B C D E F C H I J K e� N �rp3 G R 5�U V W XgTy Z 1 FIRE ALARM SYSTEM AC POWER FAILURE • • •F `:s '� "`'` 1 2 FIRE ALARM SYSTEM LOW BATTERY -�.:.'-.. �' 6; ,fir<- _'.q ,� °a'i�t'�• uR� t� w 4. _ £ z! 2 ,� J OPEN CIRCUIT I'-' � 13. � �fi�tt.r�,�a'E 3E�1'rt`,t �"�'•s �, 4, a "� b�;- 3 � •, 4 GROUND FAULT • • ' •'' h� 0, 5 NOTIFICATION APPLIANCE CIRCUIT SHORT I ��" : • •`z ��^+- y j? •�1ohf s '��'P, � �;S`"•I- J4 knF �' ��' S ' 6 e"F BUILDING MANUAL PULL STATION N sN1oK_F D_r_croR F F • F �_Ar o_rF_croR w • �;� !� • :. • r ,;,::d J� � • • �� "�m�aa„� e3�� 5:� "� sl f;x., ,mraix 9 10 HVAC AIR DUCT SMOKE _ z` OR t4 x. '" x:��: .. 4 11 HOOD OR ROOM FIRE SUPPRE SYSTEM ALARM s8' , + �` • • • • • • nq • •ra3� . . <,,a�t., e 1i2�., 12 SPRINKLER SYSTEM TAPAPER S'Pll • �a. l 12 SPRINKLER SYSTEM FLOW SWITCH`„ IN BUILDING ,,✓ � ,, u •• l �13 J 14 I` SPRINKLER SYSTEM FLOP/ SWITCH �"� " •„ IN ELEVATOR EQUIP RNI OR SHAFT I 11 • i i � , __ • m�.�1.A, Y-., • • � # �° • • •, `°': "�� 14 FIRE ALARM SEQUENCE NOTES General Fire Alarm System Sequence of Operation 1 'N Alar tem SHALL operate as follows: 1.1 Manual 0 on- operation of a manual free alarm pull station shall: 1.1.A. I A the individual station on the system cor.�s1 panel and s1 €roi _control panel and remote alarm panels a t down ventilationsystems.gh a,' a 1 Sound audible alarms and actuatekE;r )cation 1A.D. Transmit a signal to the central sta> i,"1 ,. , 1.1.E. Activate the printer. "i 2.1 ctivation of a HALL cause 2.Provideo 2.1 ' A signal d nced 3.1 ctiva f ar t 3.1.R Dis; h disp Activa" remote= riunciator panels. 3.' Record the occurrente of the event, the time of occurrence and the device initiating the event. 4.1 Receipt of a trouble signal at the fire alarm control panel SHALL cause the following actions and indications: 4.1.A. Display at the control panel and remote annunciator panels alphanumeric LCD display, the origin of the trouble condition report. 4.1.8. Activate trouble audible and visual signals at the fire control panel and remote annunciator. 4.1.C. Record the occurrence of the event, the time of occurrence and the device initiating the event. ELL MM FAC - 333 Bay&w Avenue Amka Nov York 11701 FarTan Q d)�+,;,aa StarLink SLE-LTEV-CFB-PS Fire Alarm Communicator ota Technkc�,av%� ar near o boob on M �a r) PublWy lroded an NASDAQ SKnbd; NSSC Standby Battery C a l c u l a _ion s ? NAPCO 2019 WI2335LF 4/19 Standby Current Calculations for the model SLE-LTEV-CFB-PS Fire Alarm Communicator: Stondbv Battery Caoocitv:...................................... 24 AH FIRE ALARM SYSTEM SYMBOL LEGEND QTY: SYMBOL DESCRIPTION: MOUNTING: ELEVATION: PART NUMBER: EX AC FIRE ALARM CONTROL PANEL EXISTING EXISTING MS-905OUD 1 ELL CELLULAR DIALER OWN CABINET VERIFY IN FIELD SLE-LTEV-CFB-PS 1 n Mini Module JBOX VERIFY IN FIELD MMF-301 FIRE ALARM SYSTEM WIRE LEGEND NOT ALL WIRE TYPES WILL BE USED FOR EVERY PROJECT YS MBOL IC RCUIT COLOR SCHEME AWG-CONDUCTORS WINDY CITY PART NUMBER A SLC Circuit 18G-2C FPLP 762369 (Red w/ White Stripe FPLP) B NAC Circuit 14G-2C FPLP 7679610 (Black FPLP) " ' ' C Voice Circuit 16G-2C FPLP 761362 (Red w/ Blue Stripe FPLP) D VBUS Circuit "' "'' 16G-2C FPLP 761366 (Red w/ Green Stripe FPLP) F Annunciator SBUS s . _ Jrlr., 18G-4C FPLP 762380 Red FPLP ( ) G NAC Trip Y f .t `' 18G-2C FPLP 762361 (Red w/ Black Stripe FPLP) H Auxiliary Circuit " I I 16G-2C FPLP 761363 (Red w/ Yellow Stripe FPLP) Sta,Lin <l" SLe SERIES COMMUNICATORS e e Tc•:"fEtY- i lath 10V=91nA u.•=71O,A_ N.�411.„.'r�ll.1 LLL.J iDe iiVJ2 3_L O 1 5 L-O:'r� REFER TO INSTALLATION INSTRUCTIONS W11653 r 764 NX 10 AX I II �I rJ :ilr F