HomeMy WebLinkAbout22-3641EighthAM
5335
Phone: (813) 780-0020
•
3641-2022
sue .. 03/18/2022
Complete Plans, Specifications add fee Must Accompany Application. All work shall performed
accordance with City Codes + Ordinances. NO OCCUPANCYC.O.
NO OCCUPANCY BEFORE C.O.
PERMIT
11 U. EXPIRES
rl , rt MONTHS APPROVED
G? 1 Pll INSPECTION
CALL FOR
O.R INSPECTION . 8HOUR NOTICE REQUIRED
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
Date Received Phone Contact for Permitting { 727 ) 797 �
Owner's Name Island 301 LLC Owner Phone Number f I V � � � « � -1
Owner's Address 12800 Windguard Cir Ste 101 Wesley Chapel, FL 335441 Owner Phone Number
Fee Simple Titleholder Name Owner Phone Number
Fee Simple TitleholdeF
JOB ADDRESS all Blvd Zephyrhifls, FL LOT #
SUBDIVISION PARCEL ID# 03-26-21-0010-05000-000
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED
NEW CONSTR
ADD/ALT
SIGN DEMOLISH
e
INSTALL 8
REPAIR
PROPOSED USE
SFR
COMM
OTHER
TYPE OF CONSTRUCTION
BLOCK
FRAME
STEEL
DESCRIPTION OF WORK
nstall
LED illuminated channel letters, low voltage, cannect to existing electric
BUILDING SIZE SO FOOTAGE 117.5& HEIGHT
X BUILDING S
16,428 VALUATION OF TOTAL CONSTRUCTION
X ELECTRICAL $ 54 AMP SERVICE PROGRESS ENERGY W.R.E.C.
=PLUMBING $
MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION
=GAS ROOFING = SPECIALTY = OTHER
FINISHED FLOOR ELEVATIONS E= FLOOD ZONE AREA =YES NO
BUILDER COMPANY Fastsignsof Clearwater
SIGNATURE f REGISTERED mmY / N FEE CURREN Y / N
Address 2781 Gulf to Bay Blvd Clearwater, FL 33759 License # �ES12001$44
ELECTRICIAN COMPANY tY
gns of Clearwater
SIGNATURE REGISTERED N FEECURREN _Y t N
Address 27$1 Gulf to Bay Blvd Clearwater, FL 33759 License # E512001$44 ��
PLUMBER COMPANY
SIGNATURE E=== REGISTERED YIN �IEEREN YIN �
Address License # E I
MECHANICAL COMPANY
SIGNATURE REGISTERED ;;;; �FEEREN Y / N
Address License #
OTHER COMPANY
SIGNATURE REGISTERED ;;; FEE GURREN Y / N
Address License #
RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction,
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stonnwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects
COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction.
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance
SIGN PERMIT Attach (2) sets of Engineered Plans.
****PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner & Contractor sign back of application, notarized
If over $2500, a Notice of Commencement is required. (A/C upgrades over $7500)
Agent (for the contractor) or Power of Attorney (far the owner) would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Retools if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage)
Driveways -Not over Counter if on public roadways..needs ROW
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive
than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they
may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and
contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements
may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009,
Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this
application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is
not entitled to permitting privileges in Pasco County.
TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or
expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that
such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery
Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final
power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior
to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUC71ON LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant,
have been provided with a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of
Agriculture and Consumer Affairs, If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described
document and promise in good faith to deliver it to the "owner" prior to commencement,
CONTRACTOWS/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with
all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as
indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all
laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I
understand that the regulations of other govemment agencies may apply to the intended work, and that it is my responsibility to identify what actions I
must take to be in compliance. Such agencies include but are not limited to:
- Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, WaterNVastewater Treatment.
Southwest Florida Water Management District -Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
Army Corps of Engineers -Seawalls, Docks, Navigable Waterways.
Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment,
Septic Tanks.
US Environmental Protection Agency -Asbestos abatement.
Federal Aviation Authority- Runways.
I understand that the following restrictions apply to the use of fill:
Use of fill is not allowed in Flood Zone W" unless expressly permitted.
If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the sternwall,
If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties, If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required,
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to
commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or
other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as
authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from
thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work
authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a
period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to
exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered
abandoned.
11MV41i'1921111111 WMAIMM ;1*171'ZIL14 ON !1, ,
OWNER OR AGENT/
Su0scrilted and swam to (or affirmed) before me
identification.
ALYSSA J. SWININGTON
My COMMISSION # HH209939
EXPIRES: December 20, 2025
and
N
Wh6 is/are porsonall nown to ma or has/have produced
as identification.
Public Notary Public
Commission No.
Name of NoWry typed, printed or stamped
P`4
S ALYSSA,13WININGTON
AMy COMMISSION # H11209939
EXPIRES: December 20, 2025
nC
_41
M
K1
REF ANCHORJ-�—,J, 118r
SCHEDULE U j. P m c
soups r
MPAP
..W
C AMO 1-1.
Lath DiSGOPoti£L?
SIGN TO BE CONTROLLED
BY TIME CLOCK OR PHOTOCELL
d.,
C9
2GA-120V
Cisconred
Switch
72,5"
Weatherproof disconnect switch (can be on
either side) 20 amp dedicated 11 Ov circuit.
Sign will pull 3 amps, 12 ga wire,
Ox--- Mounting Locations
,OA
0
4 6
-"T 20A - 121ill
G -,�120V
1��211,10) , , ��, � ,z system,ii—d-, , deails, &,
-15 .� - Al-
5ens,-, e� intecded. Structura d-1 fP'uti""ieProvi'=1
A�j 3 4,AISC150 ADW,1 &N� c.—i— 21) .2/2222A _.P g� AV, t �ie Af—ft wW __hd, be 5 5
Notes. b-d1J-w!. t� I�Wj be caiddd - Pt�a,�6 �s p—nid m ADW.1-1 50.), � p1asttc'/crdo`prene sp�rs PTov!&d,, Al .�., 1. _ P,.tect
Is
easyseals.com
DESIGN CALCULATIONS
F'ok"I
TRULIEVE
WALL -MOUNTED SIGNS
6601 Gall Blvd — ZephyhMs
GENERAL NOTES-
I I. Design is in accordance with the Fkorida Building Code 7th Edition (2020)
for, use within and outside the High Velocity Hurricane Zone (fJVHZ).
2, Wind loads have been calculated per the requirements of ASCE T-16 as
shown herein.
3. These engineering calculations pertain only to the structural integrity of
those systems, components, and/or other construction explicitly
specified herein and/or in accompanying engineering drawings. The
Indim
existing host structure (if any) is assumed to be in good condition,
Pg I Cover
capable of supporting the loaded system, subject to building department
Pg 2 Wind Loads
approval. No warranty, either expressed or implied, is contained herein.
Pg 3 Anchor Design
4. System components shall be as noted herein. All references to named
components and installation shall conform to manufacturer's or industry
specifications as summarized herein.
5. Where site conditions deviate from those noted herein, revisions may be
required or a separate site -specific engineering evaluation performed.
Engi�p !?Tr !4,!eal valid
6. Aluminum components in contact with steel or embedded in concrete
Shall be protected as prescribed in the 2015 Aluminum Design Manual,
No. 6760
Part 1. Steel components in contact with, but not encased in, concrete
shall be coated, painted, or otherwise protected against corrosion.
e .
rAT E
7, Engineer seal affixed hereto validates structural design as shown only.
'eb 0
Use of this specification by contractor, et, At, indemnifies and saves
Ch #67382
harmless this engineer for, all costs & damages including legal fees &
apellate fees resulting from deviation from this design.
Easy S #1111 t OvAuth If 31124
1200 14 Federal Hwy, #200
Boca Raton, FL 33432 E-d�y Seals Com Page 1
= �essysea!smm
CALCULATIONS FOR WFALL-MOUNTED SIGNS
SE 7-16 Design Loads
WALL -MOUNTED SIGNS
Building Specs
Exposure C
ASD Load Combo Coeff: 0.6
Calculations
a. 4 9
5'
3-sec gust speed pvwer Jfiow
e'tivon n:'
Kd =
0..85
Dite do a,{ity °`odor
900,
t s.'ix l�?d,XP tI ?F"4......is .?..
K t
.k.,. }
OfX'g' M,
Gvcpi .:_.
f
_ <i'F, It." P ,,,..�:.?x c. .4 ., p,x
Ke :.:,
1'0
(,`in a ,^ice 0 vaz e` .,Cto,,,
"ALL -MOUNTED SIGNS
s,
RES
ttSD WIND PRESSURES
E(Cpp C
CENTER CORNER
22
["Elt"€i' 1
4(Zone iflC rl�:.ri}`,
qZ
15 ft
h 27.4 psf 34.9 psf
.....,. ,.,u,.n
.. F ... ... _
24.9
...,..sm ....n
»...H. ...... .......
y
20 ft
29.1. psi �.� psf`
266 5
5 ft
30a5 psf 3 .9 psf
27.8
30 ft
31.7 psf 40.4 psf
28.
35 ft
32.8 psf 411 psf
29,8
40 ft
33.7 psf 42.9 psf
n 4
3t1.7
r'
45 ft
t 34.6 psf 44.0 psf '
3 p,.4
50 ft
� 35 psf 45.Q psf
3
32A
10
.9 ft
�p$
a� 3 a1 f 45.9 S@
�°`
'. x
..
32,8
i c
60 ft
36.7 psf 46.7 psf
4
33.4
70 ft
31.0 psf 6.1 psf
34.5
80 ft
31.9 psf 63.9 psf
35.5
90 ft
p 323 psf 65.5 psf
€'
36.4
,'
100 ft
33.5 psf 66.9 psf
1, 21
37,2
£pia
;
110 ft
34.1 psf 68.3 psf
s )q
37.9
tit;
2 tit
120 ft
34.8 psf 69.5 psf
38.6
£
130 ft
35a4 psf 70.7 psf
341,
393
x ,
140 ft
r� 35.9 psf 71.8 psf F
39.9
t,
150 ft
Il 36.4 psf 7.9 psf
40.5
175 ft
9 7.6 psf 75.3 psf
4,'
41.8
90
- �
200 ft
38.7 psf 77.4 psf
r
43.0
_ 8,
250 ft
40.6 psf 61,E psf
45.190
8:.?.
j S
Wall Sign Anchor Design
Structure Dimensions & Loading
Design wind pressure:
Sign type
Sign size
Wall material
Anchor type/size
f" A, I ["'I I Lt%TIONS FOR tAVIALL.-MOU NTE D SIGNS
P = 40.4 psf
Cloud Letterset
A 54.8 sqft (entire letterset)
Masonry (ASTM C90, 1,500 psi Min)
1/4" Tapcon
Relf: PRAI Tapcon, cata�og
Min Embedment: I"
Min ed�'�e di�A: NIhn sp")�ml'g� 11
Anchor tensile capacity, Tcap --x IMO 1b (per anchor')
Check Anchors for Pullout
t o"Lai Reactiow pit 2213 1b — " P'A i(ACCA'SCA)
No, of anchors req'd: n 17,7 total anchors Rt/cap
Total anchors required. 18 totW anchors balanced qver letterset,
OK, c.loud �etterset Mize show�, 4. Ref elevation detail for approx anchor locations.
Ref anchor schedule for other anchor options.