Loading...
HomeMy WebLinkAbout22-3744City 5335 Eighth Street �itl`i ,,:' $: ephyrhil FL 33542 - 4374 -2 2 Phone, (813) 780-0020 Fax: (813) 780- 021 issue gate. 05r26/2022 REINSPECTION FEES: (c) With respect i } local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspoction, whichevergreater,i , i7 , p ` additionalNotice: In addition to the requirements of this permit, there may be R this propertythat may be • additional permit required from other governmental entities such as water management, state agencies or M �. 1 iall •. 1� !. t Mgt R s y accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE 4 €€ CONTRACTOR SIGNATURE FE IT OFFICE PERRi . EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION V V 4 WINA U K-1 7- T, I I I I k1l 5335 Eighth Street Zephyrhills, FL 33542 Phone: (813) 780-0020 Fax: (813) 780-0021 Fili r " T � rn REINSPECTION FEES* (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the foe imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. n +izz' T�� I It It ra f lt nym., �1111i� �1111 Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. No OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNATURE PE 7MIT OFFICE[) PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhills Permit Application Fax-613.780-0021 Building Department SUBDIVISION � � F �A � � $? PARCEL to# (OBTAINED FROM PaPROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADDIALT SIGN DEMOLISH INSTALL 8 REPAIR PROPOSED USE SFR COMM OTHER TYPE OF CONSTRUCTION BLOCK �' FRAME STEEL jQ DESCRIPTION OF WORT{ ! b 4-n 0 � � t V\ C 6- Y 6 0 ` BUILDING SIZE SQ FOOTAGE � HEIGHT = BUILDING $ a VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ AMP SERVICE PROGRESS ENERGY W.R.E.C. PLUMBING $ ji MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION GAS ROOFING SPECIALTY = OTHER 1 FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER � -----� COMPANY t E�CUti RREN�SIGNATURE REGISTERED Address Cta Ut L c 1 CA License It C} I x1i ELECTRICIAN COMPANY SIGNATURE REGISTERED Y/ N� FEE cURREN Y f N Address License # PLUMBER COMPANY E=== SIGNATURE REGISTERED ;;;=F.=.UI111EN;;;;;= Address License # E _= = MECHANICAL COMPANY SIGNATURE REGISTERED � E=:== [ mmY I N �F.ERREN � Address License # OTHERE__ COMPANY SIGNATURE REGISTERED YIN �IEEMIRRr�NI N Address License # '�ST��d#ttlFltdrl1 RESIDENTIAL Attach (2) Plat Plans, (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction, Minimum ten (10) working days after submittal date. Required castle, Construction Plans, Stormwcater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisionsilarge projects COMMERCIAL Attach () complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms: R-O-W Permit for new construction. Minimum ten H0) working days after submittal date. Required onsite. Construction Plans, Storrnwater plans wl Slit Fence installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Flans. **`*PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign hack of application, notarized If over $2500, a Notice of Commencement Is required. (AIupgrades over $750) Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING, (copy of contract required) Remots if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage) Driveways -Not over Counter if on public roadways..needs ROW 813-780-0020 City of Zephyrhil)s Permit Application Fax-813-780-0021 Building Department NOTICE OF DEED RESTRICTiONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law, if the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing icensing Section at 727-847- 8009, Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible, If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County, TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: the undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. the undersigned also understands, that such fees, as may be due, will be identified at the time of permitting, It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release, If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): if valuation of work is $2,500,00 or more, I certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner, I certify that i have obtained a copy of the above described document and promise in good faith to deliver it to the 'owner' prior to commencement. CONTRACTOR'SIOWNER'S AFFIDAVIT: I car* that all the information in this application is accurate and that ail work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or Installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in jurisdiction, I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, WaterMastewater Treatment, - Southwest Florida Water Management District -Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers -Seawalls, Docks, )Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency -Asbestos abatement. - Federal Aviation Authority -Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone "V" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a °compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction, I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced, An extension may be requested, in uniting, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. FAWNER OR AGENT aJ b _ W �VC) Subscribed and sworn to (or affirmed) before me this Who islare ersonally known to me or hag/have produced as identification. tt��,, Notary PUt?IIC Com4.,on.s t� Name of Notary typed, printed or stamped on I mmr RITTANY ADAMS ° .; Notary public -State of Florida *Commission # GS'950378 r» My Commission Expires January 23, 2024 Subscribed and sworn to (or affirmed) before me this by Who is/are personally known to me or hasthave produced �O as identification. __LtNA_NDtary PUt7iiC Commission No, Name of Notary typed, printed or stamped ,NIAYPu. BRITTANY °a ADAMS Notary Public -State of Florlds = Commission # CG 950375 rc`>"� MY Commission Expires ,rnil January 23, 2024 �: } ,. .° «- b , } �.� 2, *�„, i F +t $� �.' �, k % i it ,�, y e Mx ♦ � at. . < i t + # r 1 .4 't 4 . t Ss � e � � ; r. .2:. I� � .:... w '. st t �a �. � r x , a <* a Parcel ID No 124�a�_ I �_n�_ NOTICE OTICE OF COMMENCEMENT Q THE UNDERSIGNED hereby gives notice that Improvement will be made to certain real property, and In accordarice VM Chapter 713, Florida Statutes, the following information is provided In this Notice of Comm -noement, r L 1. Description of Property. Parcel Identification No. S C-C 6 — StreetAddress: 0 2. General Based W c 3. owner Information or Lessee information if the Lessee contracted for the improvement, ui °d V, Nam 0 W In — Address City s state 1-119 a) 10 friterestinPropertlr r- ® N 0) (D , a , Name of Fee Simple Titleholder co G <- i-I rd C > 3 (If difibrantfrorn Omerilsted above) a N cli a 0 Address city State :M 0 4. Contractor- 0 _R 0 Name r. (- -a Address City State Contractors Telephone No�: Eta A2 31 �0_ 5. Surety, Name Address city State Amount of Bond: Telephone No.; 6, Lender. NIA Address city State Lender's Telephone No.* N1A 1 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 743.13(1)ta)(7), Florida Statutes A i 1 /-9- Name ' . A- d ress city State Telephone Number of Designated Person: AV I /-/I- 8, In addition to himself, the owner designates � if 1 Of— q to receive a copy of the Lienoes Notice as provided In Section 713JS(i)(b), Florida Statutes. Telephone Number of Person or Entity Designated by Owner. y4a 9. Expiration date of Notice of Commencement Pis expiration date may not be before the completion of construction and final payment to the contractor, but will be one yearfrom the date of recording unless a different date is specified): WAPN1Nt1,T0OWNEP! ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT Under penalty oftiedury, I declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of my knowledge and ballef, STATE OF FLORIDA COUWY Of PASCO �Z-. Owner- or Le ... ys 'S, of Domeier s% a Vi er's or Lessse!s Authorized d 'gr.cl do Director/parm ana Signatory 8miloloffice The foregoing instrument was acknowledged before me thisCal ay of, 204 by as (type of authority, e.g., officer, trustee, attorney in fact) for (name ofw90 on behalf of whom )iAtrume"Aecutcd). Personally Known E] OR Produced Identification Notary Type of identification Produced tlf 1 Name i EMMA A. KLOSI KI Notary Public -State of Florida CO-Inissioll GG 324783 koF f� V it April 17 vlll� 19 DESIGN CRITERIA: APPLICABLE CODES, REG TIONS AND STANDARDS 1. THE FLORIDA BUILDING CODE 7TH EDITION 2020 SPECIFICALLY CHAPTER 16 STRUCTURAL DESIGN, CHAPTER 20 ALUMINUM, AND CHAPTER 23 WOOD. 2. AA ASM 35 ON SPECIFICATIONS FOR ALUMINUM STRUCTURES PART I -A AND 1-B OF THE ALUMINUM DESIGN MANUAL PREPARED BY THE ALUMINUM ASSOCIATION, INC. WASHINGTON, D.C., 2020 EDITION. 1 ASCE 7-16. WIND LOADS 1--Ri ILDING OCCUPANCY CATEGORY, PARAGRAPH 16045 AND TABLE 1604.5; CATEGORY 1, 2, BASIC WIND SPEED TABLE, TABLE 1609 STATE OF FLORIDA DEBRIS REGION & BASIC WIND SPEED, PARAGRAPH 1609.3 AND TABLE 1609.3,1 EQUIVALENT BASIC WIND SPEED: 155MPH V-ULTIMATE EXPOSURE CATEGORY, PARAGRAPH 1609,4,3: C 3, BUILDING CATEGORY FOR ALUMINUM STRUCTURES, PARAGRAPH 2002,6: BUILDING CATEGORY I SPECIFICATIONS fHE FOLLOWING SPECIFICATIONS ARE APPLICABLE TO THIS PROJECT: 1. ALUMINUM EXTRUSIONS SHALL BE 6005 T5 ALLOY, 2. FASTENERS ARE REQUIRED TO BE SAE GRADE 2 OR BETTER ZINC PLATED. 3, #10 SCREWS 6FROM END AND 24'CENTER TO CENTER, 4. DOOR LOCATION SHALL BE DETERMINED BY CONTRACTOR IN THE FIELD, 5. TYPICAL SCREEN TYPE SHALL BE 18x14 6. ALL MEMBER SIZES MAY BE GREATER, BUT NOT LESS THAN, WHAT IS SHOWN ON THIS PRINT, 6A. (EXAMPLE: A 2x6 MAY BE USED IN LIEU OF A 2X5) CONTRACTOR LIGHTNING ALUMINUM, INC P0. BOX 290144 TEMPLE TERRACE, FL 33687 813-984-1185 ENGINEER CRAIG JASIN, P.E. (#82363) LIGHTNING ENGINEERING LLC. 6231 BLACK DAIRY RD. SEFFNER, FL 33584 586-873-4980 PROJECT ADDRESS HEARN 6462 DFORD WOODS DR. ZEPHYRHILLS, FL 33542 CITY OF ZEPHYRHILLS ----------- T-6' Im T— T-0" T-2'-- --� m HOUSE SCALE 1/4'= V-T T-1 T-6 AL TN SHALL. COMPLY WITM PREVAILING CODES FLORIDA BUILDING CODE, NATIONAL ELECTRIC% CODE., AND THE C"ITY OF 4-nEPHYRH I LLS- ORDINAISPICIES APR 0 4 2022 % REV 100d 7-1 y IFY'R C)r- No 363 M- PLAN Cm STATE F -7 0 A-1 CRAIG JASIN, P.E. (#82363) PLAN 591affi-luNim GUSSET DIMENSIONS 16"x6': 2x8 - 2x10 16'x4': 2x4 - 2x7 . . . . . . e 0 12'x4": 2x4 - 2x5 EXTERNAL GUSSET DETAIL ,SCALE; N.T.S. KV.*M RECEIVING BEAM CHANNEL WI (2) #10x314" INTO EACH FACE& (3) #10x314- INTO BEAM PURLIN OR GIRT TO BEAM OR POST DETAIL '�.0 E.N.T.S. (2) #1 GxZ' SCREWS THRU EXTRUSION (1) #10xT SCREW 24- O.C. 2"WDE EXTRUDED GUTTER BRACE AT EACH BEAM W/ (2) #8x3/4- A-1 0 0 NO. OF SCREWS AND PATTERN #10x3/4'INTO TO VARY. SCREWS TO MAINTAIN RECEIVING CHANNEL 1-1/4" C/C GUTTER BRACE & MATING ELEMENT ATTACHMENT DETAIL SCALE: -�Tl ALUMINUM MEMBER DIMENSIONS HOLLOW SECTIONS 2X2: 2"X2"X0.044' 2X3: 2"X3"X0.050" 2X4: 2"X4"X0.050" 2X5: 2"X5"XO.050" 3X3: 3"X3"XU93" 4X8:4"X8" ULTRA CAPE OPEN BACK SECTIONS 1X2: 1"X2"X0.040" IX3: 1"X3"X0.045- SELF MATING_(_q_MB 2X-4:2-X 044"X0.100" 2X5: 2"X5"X0.050"X0.100" 2X6: 2"X6"XO.055"X0.120" 2X7: 2"X7`X0,057"X0.120" 2X8: 2"X8"X0.072"X0.124" 2X9: 2"X9"X0.072"X0A24" 2X102"X10"X0.092"X0.398" SNAP SECTIONS 2X2 SNAP: 2"X2"X0.045" 2X3 SNAP- 2"X3"X0.050" 2X4 SNAP: 2"X4"X0,045" BEAM 2x3 RECEIVING CHANNEL SELF -MATING W/ (2) #1 OX3/4- INTO BEAM - NOTCH GIRT EACH SIDE & (3) FOR UPRIGHT W1 #1 Ox3/4' INTO 2x3 MIN, 3W O.C- #10x3/4" UPRIGHT TO BEAM CONNECTION DETAIL -SCALE--:N.T--S ---- - - BE SIZE x 4" GUSSET d"THICK) #10x314', 2'O,C, K-6\ OVER SPLICE DETAIL . '\,� SCALE: N.T.S. (2) #1 Ox2' SCREWS THRU EXTRUSION - (1) #1 CX2- SCREW 24- 0,C, 2"WDE EXTRUDED GUTTER BRACE AT EACH BEAM W/ (2) #8x3/4' Si jg NO. OF SCREWS AND PATTERN #10x3/4'INT0 - TO VARY. SCREWS TO MAINTAIN RECEIVING CHANNEL 1-114'C/C GUTTER BRACE & ANGLED FASCIA BOARD ATTACHMENT DETAIL SCALE: N.T.S, #12x3/4" TEK SCREWS (2) ROWS TOP AND BOTTOM MAINTAIN 1-1/4'0.C. SPACING 4x 8 ULTRA SCARE BEAM SPLICE DETAIL (D3 -- SCALE: N,T,S, gm 2x3 RECEIVING CHANNEL W1 (2) #1Ox314- INTO GIRT EACH SIDE & (3) #10x3W INTO 2x3 SLOPED PURLIN CONNECTION DETAIL 13 13 m DIAGONAL WIND BRACE TO BEAM CONNECTION OR 2X3 PATIO CONNECTION SCALE: N,T.S. ---- JD--- (2) 1/4" DIA. x 3-1/2' #1Ox3/4'S.M-S. 10'0.C. THRU BOLTS INTO GUTTER ALSO INTO CARRY BEAM F 0- NO. OF SCREWS AND PATTERN To VARY- SCREWS TO MAINTAIN 1-1 /4" o C/c COMPOSITE TO GUTTER TO BEAM TO 3x3 COLUMN TO BEAM SCALE:: N3..S7 #12x3,'4'TEK SCREWS (2) ROWS TOP AND BOTTOM MAINTAIN 1-1/4"O.C. SPACI NG Q' 0 4.8 ULTRA SCARE BEAM TO BEAM BRACKET DETAIL SCALE: N7 (9)#lOx3/4'SMS CABLE CONNECTION AT CORNER SCALE: N.T.S. HOUSE WALL: EITHER STUCCO/BLOCK OR WOOD FRAME 1/4'x2-114* TAPCONS TO MAINTAIN 2"O.C. FOR STUCCOIBLOCK OR #10x2'SCREWS 1"O.C. FOR WOOD NO. OF SCREWS AND PATTERN TO VARY. SCREWS TO MAINTAIN 1-1/4* CIC #1 Gx314" INTO RECEIVING CHANNEL HOUSE WALL & MATING ELEMENT ATTACHMENT DETAIL ,�-�S. LE N'TS' 4213mmm CRAIG JASIN, P.E. (#82363) LIGHTNING ENGINEERING LLC. 6231 BLACK DAIRY RD. SEFFNER, FL 335B4 586-873-4980 PROJECT ADDRESS HEARN 6462 BRADFORD WOODS DR. ZEPHYRHILLS, FL 33542 CITY OF ZEPHYRHILLS CO.. qW0 No, 2383 0'. STAT OF A- ORIV.-o L CRAIG JASIN, P.E. ( 82363) m 2"x2'xll8`ANGLE W/ SELF -MATING 2"x2"x1/8"ANGLE Wl SELF -MATING 1/8" S.S. CABLE 2) #1 Ox 3/4" EACH FACE RED. RECEIVING CHANNEL Wl (2) (2) #1 Ox 3/4 EACH FACE RED. RECEIVING CHANNEL W/ (2) FOR EACH LOAD BEARING #1 Ox 3/4' INTO EACH FACE FOR EACH LOAD BEARING #I ox 3W INTO EACH FACE CT�N POST CONNECTION 0 0 1'x2 O.B.BASE PLATE POST CONNECTION 1"x2" O.B.BASE PLATE MIN. 4"SLAB 250OPSI u PAVERS - 3"x3" OR 4"x4" COLUMN 4 CONC. W/ WWM MIN, 4" SLAB 1, DiA. TAPCONS 0 P"F 25( FIBERMESH 1-114' MIN CONCRETE CONC wt WWM OR DIA. TAPCONS ANCHOR EMBEDMENT CONCRETE 0 SIDE VIEW TYP. ALL FIBERMESH SIDE VIEW ANCHOR EMBEDMENT 4" SLAB MIN TYP. ALL 2 24'0 C MAX 4'0,CMAX I"x2' BASE PLATE r I'XZ' BASE PLATE (2) 4"x 2-114" TAPCONS ANCHORED CONC. ANCHORED CONC. 1-1/4'MIN CONCRETE 14" DIA, TAPCONS DIA. TAPCONS 2500 PSI CONC, ANCHOR EMBEDMENT TYP, AT 24'O.C, MAX� '"DIA, TAPCONS AT 24' O-C. MAX, DIA, TAPCONS 4 ALL WWM OR FIBERMESH t 1-1/4" MIN CONCRETE 1-1 /4' MIN CONCRETE ANCHOR EMBEDMENT FRONT VIEW ANCHOR EMBEDMENT FRONT VIEW - TYP. ALL TYP. ALL �I (*15 _E CONNECTIONS AT FOUNDATION 2.x4'OR LARGER UPRIGHT TO DECK DETAILS 'OR LARGER UPRIGHT TO DECK w/ PAVERS DETAIL SCALE: N,TS. ow 2'x4 SCALE: N-T.S. SCALE: NJS. 2500 PSI (MIN) W/ (1) #5 CONT. 2500 PSI (MIN) (MIN) 8-x8- w/ (1),45 CONT. MIN T:: CONTINUOUS FOOTING DETAIL 10(INSTALLED BY OTHERS) 9 SCALE: N.T.S. 4'X4' COLUMN —#1Gx3/4- INTO----- I 4'X4' RECEIVING PLAN r 'OLUt,4Nl CHANNEL @ 1-1W O/C FRONT 1 4�'X4" (2) 3/8- DIA, THRU COLUMN OLUMNI BOLTS LENGTH VARIES SIDE 4-X4- COLUMN OLUMN ROTATED 4X4 COLUMN TO BEAM 3" x 0.032 x 1 LB EPS PANELS (ALLOWABLE CLEAR SPAN CHARTS) NET MAX ALLOWABLE SPAN (FT) ALLOWABLE L LOAD (F)SF) L/80—_ L/I L/1 80 U240 10 17.50 17.50 16.91 15.96 20 16,64 15,96 14,06 12.16 30 15.17 14.06 11.21 8.36 40 13.69 12.16 8.36 4.56 50 12.22 1026 5.51 0.76 60 10.75 8.36 2.66 - 70 80 9.27 7.80 646 .5 3-1/8"xl-1/2"x 1/8'BASE Wl (2) 1/4- DIA, TAPCONS OR EQUIV. POST W/ (2) 3/8"DIA. THRU BOLTS LENGTH VARIES li'DIA, TAPCONS 1-1/4" MIN CONCRETE ANCHOR EMBEDMENT TYP. ALL 3x3 OR 4x4 COLUMN TO PAVER OR PATIO ATTACHMENT (08 SCALE: N.T.S. SCREEN ENCLOSURE #1 Ox3/4" INTO RECEIVING CARRIER ROOF BEAM FLOOR SYSTEM CHANNEL TO POST TO BEAM (SIZE MAY VARY) MA .10 - 2� VARY) ROOF BEAM 0 2"x4'- 2'x1O' #1 Ox314' INTO RECEIVING (SIZE MAY 0 16' BLOCK STEM CHANNEL TO CARRIER BEAM VARY) WALL Wl (1) 6"x6' POST - HEIGHT TO #5 DOWELED INTO FOOTER TO MAINTAIN 1-1/4" O.C. 2'x4'- 2'xlT @ 6'CLC. VARY, TYP. 2"x2'xII8' HEAVY ANGLE EA, 0 SIDE W1 (2) TAPCONS EA, V �RY MAINTAIN 1-114, O.C. (SIZE MAY ZX4' )// 2 JG_ ANGLE RECEIVING CHANNEL GRADE W/ #1 Ox3/4' MAINTAINING (2) - 318- DIA. THRU BOLTS CONT, 8'WIDE x 8"DEEP 1-1/4" O.C. 5 7/8'x1 1/2x118" BASE CONVENTIONAL CONC, FOOTER DIA. W/ (6) 113- CIA TAPCONS RECEIVING WTAPCONS OR EQUIV. / (1) #5 CONT. LAP SPLICES MIN, CHANNEL SIDE VIEW TOP VIEW 25'& TIE W/ WIRE, % F- TYP. @ 1-1/4" MIN F E-TE.- SIDEVEW 01 DIA. TAPCONS, 1-1/4- MIN NOTE: ,C,,,cSFTE PERIMETER CONCRETE STE 5ASE CONGR F3AS__] CONCRETE ANCHOR -NO. OF SCREWS & PATTERN TO VARY BASED ON BEAM SIZE. ANCHOR L___ ­ - E EMBEDMENT TYP. ALL -SCREWS TO MAINTAIN 1114' O.C. EMBEDMENT CMU ANCHORING DETAIL TYP. ALL 6.6 POST ATTCHMENT DETAIL F BEAM TO CARRIER BEAM CONNECTION SCALE:L E--N :- --T ­_ SCALE: N.T.S. 22 EGG S­_N.T.S.N.TSAN.Y.S. ( W"WITH #1 OX3' S M.S. THRU #10x3'S.M.S. THRU FASCIA INTO RAFTER NEO WASHER FASCIA INTO RAFTER TAILS, 24" O,C. 3" HEADER TAILS, 24'CLC. COMPOSITE /-(3)#l2x4'S,M.S- COMPOSITE (3) #1 Ox314" ------ ROOF PANELS WITH WASHER, RO�OFF COMPOSITE S.M.S. PER PAN 3" COMPOSITE PER PANEL 3x2 W H R 3- _OMPOSITE 3.2 (4) #10x 3W --------- S,M,S, PER #1 Ox 3/4' SJVC& 10' #1 Ox 3f4' S.M.S. PER CONNECTION Io O.C. TOP AND PANis 7BIOTTOM 3x2 T O.C. COLUMN COLUMN (4) #1 Ox 3/4' S.M S PER COMPOSITE ROOF HEADER TO FASCIA ATTACHMENT AND COMPOSITE ROOF I PAN ROOF HEADER TO FASCIA ATTACHMENT To LOAD -BEARING WALLFL, PRODUCT APPROVAL-FL7561-R4 - EXP.- 12/30/2022 D25 AND PAN ROOF TO LOAD -BEARING WALL SCALE: N.T.S. SCALE: N.T_S_ 3' HEADER Wl (2) #1 Ox3/4" INTO 3x3 FACE & (2) #1 Ox3/4' INTO 3" COMPOSITE PANEL @ 12- OG, 3" COMPOSITE PANEL TAPE OR CAULK EXTERIOR GAPS, TYP, 3' HEADER W/ (2) #1 Ox314' INTO 3' COMPOSITE PANEL 4" DIA- TAPCONS AT 24' @ 12- O.C. O.C. MAX. 3" HEADER 1-114'MIN CONCRETE MIN. 4' SLAB 2500 PSI ANCHOR EMBEDMENT CONC. wf WWM OR TYP, ALL FiBERMESH 3- COMPOSITE WALL DETAIL (Wl 3x3 BEAM) (�2%%7 SCALE: N.T.S. SUPER ­__ i GUTTER CONNECTION 4 2 6) KNEE WALL PETAILTO GUTTER \t! SCALE: N,TS, CONTRACTOR AfRomm CRAIG JASIN, P.E. (#82363) LIGHTNING ENGINEERING LLC, 6231 BLACK DAIRY RD. SEFFNER, FL 33584 586-873-4980 HEARN 6462 BRADFORD WOODS DR. ZEPHYRHILLS, FL 33542 CITY OF ZEPHYRHILLS %% E N 82363 s OF x R.% A-3 CRAIG JASIN, P.E. (#82363) DETAILS