Loading...
HomeMy WebLinkAbout22-3750ty of Z p Eighth5335 Phone: ♦ i +13) + • /i Issue Date: 03i151 022 • • i T w • # i * i * is • " �� ♦ + .#� c. Fe +. accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. ,4 QL r EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED +.III 813780 0020 City of Zephyrhills Permit Application Fax -ale ys0-0021 Building Department 3 �—o Date Received %1t Phone ontactforPormicting *sift Ownoes Name Hayward Lampley Owner Phone Number 303-619-5036 Owner's Address 71 ) Stoer 3ia e r,, p1�}r I1ills, E"I 33541 Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address t S lift i., p till IS, I33541 JOB ADDRESS 71 E 5toor l3lad i)r., cphyrlr�lls, l l 3 3 1 LOT # SUBDIVISION _. m _ � .� PARCEL (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEWOON5TR ADDIALT SIGN DEMOLISH INSTALL REPAIR PROPOSED USE SFR ED COMM OTHER TYPE OF CONSTRUCTION BLOCK FRAME STEEL DESCRIPTION OF WORK l��stall Plloio� oltaic IZ�iicevabl� rtor�Y alar �ysto>II on tltc root BUILDING I ==RQFOOTAGE HEIGHT BUILDING $ VALUATION OF TOTAL C6031TRUCTION ELECTRICAL AMP SERVICE PROGRESSENERGY W.R.E.C. PLUMBING fr d MECHANICAL VALUATION OF MECHANICAL INSTALLATION GAS ROOFING SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA YES NO BUILDER C SIGNATURE CaINPEANYo / N FEE 4URREN Y I N Address License # ELECTRICIAN� COMPANY 8 � � ' C SIGNATURE REGISTSED Y / N FEE GURREN Y / N Address License # PLUMBER COMPANY YNSEEcuSIGNATURE ReGisTEREo e Address License # MECHANICAL COMPANY _... ,, .. . SIGNATURE REGISTERED % N�� FEE CUR tEN Y l N Address License # OTHER COMPANY Freedom Solar E�J�a� sin'NF SIGNATl2E REGirD �E Address 5 _ Gall Bled. l�vrltills_ FL 335 2 License # EEi RESIDENTIAL Attach (2) Plot Putts; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction, Minimum ten (10) working days after submittal date. Rewired onsits, Construction Plans, Stormwator Plans w/ Silt Fence Installed; Sanitary Facilities& 1 dumpster; Site Work Permit for subdivisions/large project COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms, R-OW Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities S 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. irectlons: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2600, a Notice of Commencement Is required. (AID upgrades over $7600) Agent (for the contractor) or Power of Attorney (for tha owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage) Driveways -Not over Counter if on public roadways -needs ROW 61.5-ruu-1,lutu city of Zephyrhllls Permit Application rax-613.180_0021 Building Department N TICS OF DEED RESTRICTIONS: The updersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions, UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations: If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division --Licensing Section at 727-84 -8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contraotdris) sign portions of the "contractor Block" of this application for which they veld be responsible, if you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands,that such fees, as may be due, will be identified atthe time of permitting. it is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certiflcate of occupancy' or final power release, ifthe project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): ifvaluation of work is $2,500,00 or more, I certify that I, the applicant, have been provided with a copy of the' Florida Construction Lien Law-1-Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other then the "owner", i certify that I hove obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement, CONTRACTOR'S/OWNER'SAFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, Zoning and land development Application Is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work Wit be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction, I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection -Cypress Sayheads, Wetland Areas and Environmentally Sensitive Lands, WaterMastewater Treatment. - Southwest Florida Water Management district -Wells, Cypress Sayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers -Seawalls, Cocks, Navigable Waterways. _ Department of Health & Rehabilitative Services/E.nvironmental Health unit -Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency -Asbestos abatement. - Federal Aviation Authority -Runways. I understand thatthe following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone'V" unless expressly permitted. - If the fill material is to be used in Flood Zone "A°' it is understood that a drainage plan 'addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida, - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that rill will be used only to fill the area within the stemwall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. if I am the AGENT FOR THE OWNER, i promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understandthat aseparate permit may be required for electrical work, plumbing, signs, wells, viols, air conditioning, gas, or other installations not specificaliyincluded in the application, A permit issued shall be construed to be a license to proceed with the work and not as authority to violate; cancel alter, or set aside any provisions ofthe technical codes, nor shailissuanceare permit prevent the Building Official from thereafter requiring a correction of errors in plans construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a - period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension: if work ceases for ninety (90) consecutive days, the job is considered abandoned. AOENT Kwia\autiran no sworn to (or affirmed) before me this 91 INE DIAGRAM SAP JV� ATTACHMENT PLAN ATTACHMENT DETAILS E SAFETY PLAN ELECTRICAL CALCULATIONS MODULE DATASHEET ARRAY WIRING BOX DATASHEET ARRAY WIRING BOX DATASHEET MOUNTING SYSTEM DATASHEET PROJECT DETAILS PROPERTY ADDRESS P�RESIDENTIAL ONE- OR TWO-FAMILY DWEWNG GROUP (GROUP R3) ERGY _FLORIDA INC CONTRACTOR. INFORMATION ADDRE CONTRA TOR SIGNATURE 1 PLOT PV-1 SCALE: NTS West South 2 LOCALE PV-1 SCALE: NITS SCOPE OF FORK DESCRIPTION ARRAY WRING MICROINVERTERS, MICROINVERTERS INTERCONNECTION DETAILS POINT OF CO ECTIO is SITE DETAILS l GENERALNOTES EQUIPM�Ni DFLiTO BE WORKED UPON WHILE ENERGIZED SHALL BE INSTALLED IN LOCATIONS THAT SATISFY MINIMUM WORKING CLEARANCES PER NEC 110,26, 4 SITE PLAN PV\SCALE: « = 20 SITE f\2 PNII-25 AC MODULE 327W I 8IN 8IN 9IN ARANCH BRANCH BRANCH ILA _j JUNCTION BOX jBi 2 171\ A Fl-2 150A Swl . 60A CB4 f- AS COMBINER cl IL PV DISCONNECT it-, LOADS L,�E��15tOAZI AC GEC KIVV*ivp) UPLITYMETER ow 11 REF. I QTY. RATED CURRENT MAX VOLTAGE 3 3 20A 24WAC I F1-2 1 2 50A 240VAC I=CB4 = � 240VAC NOTES ZL ENPHASE SYSTEM MEETS REQUIREMENTS FOR PHOTOVOLTAIC RAPID SHUTDOWN SYSTEM (PVRSS), AS PER NEC 690.12(B). MICROINVERTER BRANCH CIRCUIT CONDUCTORS ARE MANUFACTURED ENPHASE Q CABLES LISTED FOR USE IN 20A OR LESS CIRCUITS OF ENPHASE IQ MICROINVERTERS, THEY ARE ROHS, OIL RESISTANT, AND UV RESISTANT. THEY CONTAIN TWO 12 AWG CONDUCTORS OF TYPE THHN/THRJN-2 DRYV4ET AND CERTIFIED TO UL3003 AND UL 9703, DO PV CONDUCTORS ARE NOT SOLIDLY -GROUNDED, NO DO PY CONDUCTOR SHALL BE WHITE- OR GRAY -COLORED ALL METAL ENCLOSURES, RACEWAYS, CABLES AND EXPOSED NONCURRENT -CARRYING METAL PARTS OF EQUIPMENT SHALL BE GROUNDED TO EARTH AS REQUIRED BY NEC 250.4(A) AND PART III OF ARTICLE 250 AND EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45. THE GROUNDING ELECTRODE SYSTEM SHALL ADHERE TO NEC 690.47(A) AND NEC 250.169. THE DC GROUNDING ELECTRODE SHALL BE SIZED ACCORDING TO NEC 250.166 AND INSTALLED IN COMPLIANCE WITH NEC 250.64, AC AGGREGATION PANEL BUSBAR AND THE OVERCURRENT PROTECTION PROTECTING THE BUSBAR SHALL BE SIZED IN ACCORDANCE WITH NEC 705.12(B)(2)(3)(c). POINT -OF -CONNECTION IS ON LOAD SIDE OF SERVICE DISCONNECT, IN COMPLIANCE WITH NEC 705.12(13)(2X3)(A), OUTPUT IS BACKFED THROUGH BREAKER IN MAIN PANEL. AV SYSTEM DISCONNECT SHALL BE A VISIBLE KNIFE -BLADE TYPE DISCONNECT THAT IS ACCESSIBLE AND LOCKABLE BY THE UTILITY. THE DISCONNECT SHALL BE LOCATED WITHIN 10 FT OF UTILITY METER. DISCONNECT SHALL BE GROUPED IN ACCORDANCE WITH NEC 23072. CONDUCTOR AND CONDUIT SCHEDULE WIELECTRICAL CALCULATIONS CURRENT -CARRYING _�l MAX. TERM. ID TYPICAL CONDUCTOR CONDUIT/CABLE TEMP. CORR.CONT, DERATED AMP. @ TERM- CONDUCTORS IN CORD EGOFILL FACTOR CURRENT BASEAMP. TEMP. EO ' FILL FACTOR LENGTH VOLTAGE R CONDUIT I CABLE FACTOR CURRENT AMP. TEMP. RATING RATING DROP 1 1 12 AWG THWW2, COPPER 05' DIA. FLEXIBLE 6 20A 12EAM R 0.76 tt4-U) Ss IS48A 13AA 30A 18,24A 94°C 30A 48A JOE 27FT 0.47% STEEL , 2 1 12 AWG THWN-2, COPPER 0.5'DIA. FLEXIBLE ETHWN-2, ECOPPER $ 10 8 6 20A 12 AWG THWN-2, COPPER 0.76 (54°C) DS 10.48A 131A 30A 1&24A 90°C 30A 1 27FT OA7% STEEL 3 1 12 AWG THWN-2, COPPER 0.5'DIA, FLEXIBLE (54°C7 W THW"' COPPER 0 6 5408 11 9 6 20A 12 AWG THWN-2, COPPER 0311 0.8 1139A 1434A 30A 18.24A 90°C 30A 7FT STEEL —7757A.EmT 4 1 BAWG THON-276PPER El 2 4 5 8 AWG THV-X2, COPPER 07"" Ef- 24IN SINGLE -LINE DIAGRAI tPV-3) tLE: NTS 13W/l/1"I "N' A&' SINGLE -LINE DIAGRAM PROJECT ID: 173420 -DATE: 03103/22 CREATED BY: N CHECKED BY: Cl - AC COMBINER ENPHASE IQ COMBI;•JER 3�. __s._m.®� SW1 - DISCONNECT EATON DG222NRB ASP - MAIN SERVICEPANEL SEE NOTE NO.4 (MSP) NEC690.56(C)(1) AND NFPA 111.12.2.1.1.1.1,11.12.2.1.4 1,e.,/ AC COMBINER PANEL (Cl) NEC705.12(B)(2)(3)(C) C EACH DISCONNECTING MEANS FOR �,eJ PHOTOVOLTAIC EQUIPMENT (SW1) NEC690.13(B) ANY AC ELECTRICAL PANEL THAT IS FED BY BOTH THE UTILITY AND THE PHOTOVOLTAIC SYSTEM (MSP) NEC705.12(B)(3) 1.a_i POINT -OF -INTERCONNECTION OR AT MAIN SERVICE DISCONNECT (MSP) NE0690.56(B),705.10 AC SOLAR DISCONNECT (SW1. CB4IN MSP) PV SYSTEM DISCONNECT `,._:_.0 AC DISCONNECT (SW1, C84IN MSP) MAXIMUM AC OPERATING CURRENT: 32.8A MAXIMUM AC OPERATING VOLTAGE: 240V NEC690.54 LABELING NOTES ALL PLAQUES AND SIGNAGE REQUIRED BY 2017 NEC AND 2018 NFPA 1 WILL BE INSTALLED AS REQUIRED. CAPITALIZEDOF 318" IN BLACK ON A RED BACKGROUND, AND REMAINING TEXT SHALL BE MINIMUM HEIGHT OF 3116" IN BLACK ON WHITE BACKGROUND SAFETY LABELS m alm ROOF PROPERTIES ROOF MATERIAL COMPOSITION SHINGLE (1 LAYER) SLOPE 6112 (26.6°) MEAN ROOF HEIGHT 16.2FT DECK SHEATHING 15/32" OSB CONSTRUCTION TRUSSES (2X4 TOP -CHORD), 24IN CC MODULE MECHANICAL PROPERTIES MODEL SUNPO SPR-E20-327-E-AC DIMENSIONS (AREA) 6131N X 41.21N X 1.81N (17.5 Sty � WEIGHT 41 LB MOUNTING SYSTEM PROPERTIES RAIL MODEL IRONRIDGE XR10 ANCHOR MODEL SUNMODO K 053-BK3 (FLASHED), 3.51N AIR GAP FASTENING METHOD EMBEDMENT IN ROOF DECKING WITH 4 FASTENERS 72.01N (ZONE 1) MAX. ALLOW. RAIL SPAN 48.01N (ZONE 2) 24,01N (ZONE 3) 72.01N (ZONE 1) MAX. MOUNT SPACING 48.01N (ZONE 2) 24.01N (ZONE 3) MAX. ALLOW, 28.81N (ZONE 1) CANTILEVER 19.2IN (ZONE 2) 9.61N (ZONE 3) AND INTEGRAL GROUNDING CERi1FIED [GROUNDING BONDING TO UL 2703 REQUIREMENTS NOTES TRUSS LOCATIONS ARE APPROXIMATE, ACTUAL LOCATIONS MAY DIFFER AND CONTRACTOR MAY DEED TO ADJUST MOUNT LOCATIONS. IN NO CASE SHALL THE MOUNT SPACING EXCEED "MAX. MOUNT SPACING„ io P-1 73420 d, W. <- RIDGE LLJ �Q RIDGE ui ui ui LJJ ui EAVE a WIND ZONE I WIND ZONE 11 \MND ZONE III DISTANCE a IS EQUAL TO 10% OF THE BUILDINGS LEAST HORIZONTAL DIMENSION OR 40% OF THE DEAN ROOF HEIGHT, WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF THE LEAST HORIZONTAL DINIENSIrJ' ICJ OR 3 FEET (GCSE 7- ®. 10). THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE PLANES OF ROOF CORNERS, RAKES, HIPS, EAVES, MANSARDS, AND RIDGES OF ROOF FACES. ����C'��� a = (MIN(0.4 * MEAN ROOF HEIGHT, 0.1 ' LEAST HORIZONTAL DIMENSION), 0.04LEAST HORIZONTAL DII+7& SION, 3 FT) 6.5 FT = X(MIN(0.4" 16.2 FT, 0.1 ' 70.0 FT), 0.04' 70.0 FT, 3 FT) 1 TTLHNT PLAN ORTHOONL PROJECTION S C A / Ml = am A ', RACKING ELEVATION IT RANSVERSE VIEW SCALE: NTS IRONRIDGE UNIVERSAL FASTENING OBJECT WITH STOPPER SLEEVE IRONRIDGE END CAP COMP. SHINGLE ROOFING IRONRIDGE XR10RAIL ROOF FRAMING SPACING ROOF DECKING / ROOF FRAMING RACKING ELEVATIQNJL�Nqf DINAL VIE NTS SCALE: ffiffm ATTACHMENT SPAN MOUNTING SYSTEM NOTES II FLASHING SHALL BE APPLIED IN ACCORDANCE WITH MANUFACTURERS' INSTRUCTIONS. LIF THERE IS ANY CONFLICT BETWEEN WHAT IS DEPICTED HERE AND INSTRUCTIONS 2 PROVIDED BY A MANUFACTURER, THE MANUFACTURER'S INSTRUCTIONS SHALL SUPERCEDE. IRONRIDGE UNIVERSAL FASTENING OBJECT/ PV MODULE RAIL SUNMODO NANO DECK MOUNT SEALING WASHER COMP, SHINGLE ROOFING ROOF UNDERLAYMENT ROOF FRAMING ROOF DECKING SUNMODO NANO GASKET SELF -TAPPING SCREW EMBEDDED INTO ROOF DECKING, C ATTACHMENT EVIL (TRAN/E EV EW OJA SCALE: NTS PV MODULE IRONRIDGE UNIVERSAL FASTENING OBJECT WITH STOPPER SLEEVE IRONRIDGE END CAP SEALING WASHER COMP. SHINGLE ROOFING ROOF UNDERLAYMENT ' ROOF DECKING SUNMODO NANO GASKET IRONRIDGE XR10 RAIL SUNMODO NANO DECK MOUNT ROOF FRAMING SELF -TAPPING SCREW EMBEDDED INTO ROOF DECKING, ATTACHMENT DETAIL (LONGITUDINAL VIEW) TSCALE:NTS___ P- 173420 cr_ i CERT41FIED: 13WIP - �­L* * 66-i i ATTACHMENT DETAILS @�IIRE SAFETYPLAN SCALE; 1. = 20' GENERALNOTES 1,5 FT. WIDE FIRE ACCESS PATHWAY 3.5 FT, WIDE SMOKE -VENTILATION SETBACK, PER NFPA 111,12.222.2 (; 3.0 FT. WIDE FIRE ACCESS PATHWAY, PER NFPA 1 11,12.2,2.2.1 1.5 FT. WIDE FIRE ACCESS PATHWAY ROOF ACCESS POINT & ROOF ACCESS POINT PV MODULES INSTALLED ON ROOF WITH IRONRIDGE ROOF MOUNTING SYSTEM, THE MOUNTING SYSTEM IS UL 1703 CLASS A FIRE RATED ON A 6/12 SLOPED ROOF WHEN INSTALLED NTH TYPE I OR 2 MODULES. THE 3.0 FT. WIDE SMOKE -VENTILATION SETBACK, PER NFPA 11112222.2 THIS SYSTEM UTILIZES MICROINVERTERS, THERE ARE 9 NO DC CIRCUITS OUTSIDE OF THE ARRAY PERIMETER OR INSIDE THE BUILDING. ALL ARRAY CIRCUITS SHALL BE ROUTED THROUGH THE INTERIOR OF THE BUILDING, AND WHERE 10 POSSIBLE, ALONG THE BOTTOM OF LOAD BEARING MEMBERS. NO CONDUIT SHALL BE INSTALLED ABOVE THE ROOF, CERT11FIED: AZ SAFETY FIRE mm IE=!!!= A. Maximum Voltage of PV Source Circuit 69.1V see 6Y07tA) NEC 690.7(X) requires that if the PV module manufacturer provides a temperature coefficient of open -circuit voltage, it must be used to calculate the PV array's maximum system voltage. It includes an information note recommending the use of the ASHRAE'Extreme Annual can Minimum Design Dry Bulb Teml)erature'as the design low temperature. Using these values, the module Voc; (64.-av) will increase to 69.1V at the design low temperature ( I 'C). (I -C - 25°C) X -0, 1 75VIC + 64.9V = 69.1V The module Voc at the design low temperature is % 1 V. 69AV X 1 = 69.1V A. Continuous Current 1�.4SA Equipment maximum rated output current is 8 X 1.31 A = I O. 48A B, Ampacity of Conductor 30A &-a Tate 310 15(3)(16) Ampacity (30'C) fora copper conductor with VC insulation in conduit/cable is 30A, C. Derated Ampacity of Conductor 1824A '9 j",� see Tabla 310 15(3)(3j(c) Table VO l5(8)(3)(9)� andk#.-Lb 100 The temperature factor for 9TC insulation at 54'C is 0.76. The fill factor for aconcluillcable that has 6 wires is H. The ampacity derated for Condtions of Use is the product of the conductor ampacity (30A) multiplied by the temperature factor (0.76) and by the fill factor (0.8). 30A X 0.76 X 0.8 = S24A D. Max Current for Terminal Ternp. Rating 30A see f/O. f#Q The lowest temperature rating for this conductor at any termination is 90°C. Using the method specified in 110. 1 4(C), the maximum current permitted to ensure that the device terminal temperature does not exceed its W*C rating would be the amount referenced in the 90'C column in Table 310.15(B)(16), which is 30A. E. Minimum Allowed OCPD Rating 13A see 2404 NEC 690.9(B) requires that the OCPD be rated for no less than 1.25 times the Continuous Current of the circuit. 10,48A X 1,25 = 13, 1 A rounded down to 13A F. Maximum Allowed OCPD Rating see 2404(IJ) NEC 240.4(D) requires that OC-PD rating not exceed 20A when Protecting a Copper 12 AWG conductor. ... Required EGC Size 12 AG see Ta�ls 250 122 !E= The smallest EGC size allowed is 12 AVVG for OCPD rating 20A according to Table M-122 H. Minimum Recommended Conduit Size see 3001T The total area of all conductors is O. I 197in', With a maximum fill rate of 0.4, the recommended conduit diameter is 0.5, 2L 2212LreLion Size Tvpe ... Area Total Area fi Conductor 12 AWG THWN-2 10, 133hf 0,0798in' L_Lqu�Groun�dL2AWG IFWN-2_ 10,0133in`]0039 le 9 O. 197.,!L_ 0.1197ir? / 0-4 = 0.2993iril (Corresponding to a diameter of 0.5') NEC Code CakuMm A. Continuous Current 10A8A see M/C/,- too Equipment maximum rated output current is 8X 1,31 A= 10.48A B. Ampacity of Conductor 30A see Table 31015(8)(16) Ampacity (30°C) for a copper conductor with 90°C insulation in ooncluft/cable is 30A. C. Derated Ampacity of Conductor 1824A see Table 3fO f 5(9)(3)(,-) Table 310 f 5(B)(3)(a) anaArIlole /00 The temperature factor for WC insulation at WC is 0.76. The fill factor for a condualcable that has 6 wires is 0,8. The ampacity derated for Conditions of Use is the product of the conductor ampacity (30A) multiplied by the temperature factor (0.76) and by the fill factor (0.8)- 30A X 0-76 X 0.8 = 1814A D. Max Current for Terminal Temp. Rating 30A see /W f4(C) The lowest temperature rating for this conductor at any termination is VC. Using the method specified in 110. 14(C), the maximum current permitted to ensure that the device terminal temperature does not exceed As 90'C rating would be the amount referenced in the GO'C column in Table 310.15(B)(I 6), which is 30A. E. Minimum Allowed OCPD Rating 13A S662404 NEC 690.9(B) requires that the OCPD be rated for no less than. 1,25 times the Continuous Current of the circuit. 10,48A X 1,25 = 131 A rounded down to 13A 1 G. Minimum Required EGC Size 12 AWG see Table 250 122 The smallest EGC sae allowed is 12 AWG for OCPD rating 20A according to Table 2% 122. r Minimum I see Minimum Recommended Conduit Size 0.5'diaj 'MU s 'o ee 300 17 The total area of all conductors is O. I 197ir?, With a maximum fill rate of 0.4, the recommended conduit diameter is 0.5. Type Area Told Area [Q—ty —Descdpton Size t]4 Conductor 12AWG THWN-2 0-01334? 0.079&r? 3 12 AWG TMN-2 0.0133in' OM99ire 9 a1197ir? 0, 1197in' / 0,4 = 0.2993ir? {Corr ding to a diameter of 0.5) 1774?7471 V7711771T?�� T NECCOI:1910"Mma ,�. Continuous Current 11.�9A Equipment maximum rated output current is 9 X 1,31A = 11,79A B. Ampacity of Conductor Ampacity (30°C) for a copper conductor with 90°C insulation in conduiticable is 30A, C. Derated Ampacity of Conductor 18,24A ,9 , f5 see Table 3fO, 15j8)(3)(c), 7able? 310 f5(B)(3)(a), andMicb fOO The temperature factor for 9TC insulation at 54°C is 0,76. The fill factor for a conduit/cable that has 6 wires is 0,8. The amPacity derated for Conditions of Use is the product of the conductor ampacity (30A) multiplied by the temperature factor (0.76) and by the fill factor (0.8), 30A X 0.76 X 0.8 = 18.24A LD. Max Current for Terminal Temp. Rating 30A see If 0 14fQ The lowest temperature rating for this conductor at any termination is 901C. Using the method specified in 110. 14(C), the maximum current permitted to ensure that the device terminal temperature does not exceed As 9TC rating would be the amount referenced in the 90'C column in Table 31 O. 1 5(B)(I 6), which is 30A. E. Minimum Allowed OCPD Rating 15A see 2404 NEC 6K 9(8) requires that the OCPD be rated for no less than 125 times the Continuous Current of the circuit. 11,79A X 1.25 = 14.74A -------------------------------------------- Fl--------------m --------------------------------------- LF. Maximum Allowed OCPD Rating 20A F. Maximum Allowed OCPD Rating 20A see 240 4(D) sLaa240 4(D) NEC 240.4(D) requires that OCPD rating not exceed 20A when NEC 240.4(D) requires that OCPD rating not exceed 20A when protecting a Copper 12 AWG con or. protecting a Copper 12 AWG eon or. G. Minimum Required EGC Size 12 AEG see Table 250 922 The smallest EGC size allowed is 12 AWG for OCPD rating 20A according to Table 250.122. H. Minimum Recommended Conduit Size 0.5'dia. see 30017 The total area of all conductors is O. I 197in', With a maximum fill rate of 0.4, the recommended conduit diameter is c5. Q Des ' tion size T e Area Sze F00133,,��0,0798,, F6 ties 412 =MN Total Area ai AWG T 3 E uipffentGround 12 AWG ITHWN-2 0.ik133W 0, ' 0.1197W/0.4=0.2993ir?(Corr espondngtoadiameter ofO.5') G. Minimum Recommended Conduit Size The total area of all conductors is 0.9 309ir?. With a maximum fill rate of OA the recommended condur: diameter is 075, Q Descri bon Size Type Area Told Area 2 Conductor 8 AWG TMN-2 OMffin' 0,0732ft? ;lNeub'sl!] 8 AEG THWN-2 0,2366ir� W 0.0366in' I E u! ment Ground 10 AWG 1HWN-2 L0211in' L1�211in` 4 LL3pn' j 0.1309.nl/0.4= 03273in' (Corresponc5ngtoacOameterOfOr75') A. Continuous Current 3275A ,vt "'� f, '0 'VeAdiOL. foo Equipment maximum rated output current is 32.75A BE. Ampacity of Conductor 55A Table see Table 3 10 �f5(8)f f 6) Arripacity, {30°C) for a copper conductor with 90°C insulation in concha lcable is 55A, C. Derated Ampacity of Conductor 52.8A see Tabla 310 15t8)t3)toj, Table M 15(8)t3)(a), andAlicle 100 The temperature factor for 90°C insulation at WC is 0,96. The fill factor for a concluit/cable that has 2 wires is 1. The ampacity derated for Conditions of Use is the product of the conductor ampacity (55A) multiplied by the temperature factor (0.96) and by the fill factor (1). 55A X O.96 X I = 52,8A D. Max Current for Terminal Ternp. Rating 50A see M. M(C) The lowest terriperature rating for this conductor at any termination is 75°C. Using the method specified in 110, 14(C), the maximum current permitted to ensure that the device terminal temperature does not exceed its 75°C rating would be the amount referenced in the 75°C column in Table 31 O. I 5(B)(I 6), which is 50A E. Minimum Allowed OCPD Rating 41A see 2404 NEC 690.9(8) requires that the OCPD be rated for no less than 1.25 times the Continuous Current of the circuit 32.75A X 1.25 = 40.94A F. Tie Required EGC Size 11 AWG Required e 7 , e a 21122 The smallest EGC size allowed is 10 AWGG for OCPD rating 50A according to Tabp 250.122. UtW-771P,=TT� A. Continuous Current 32.75A see Mlcle /00 Equipment maximum rated output current is 32.75A B. Ampacity of Conductor 55A see Table 31a 15(8)(16J Ampacity (30°C) for a copper conductor with VC insulation in concludIcable is 55A C. Derated Ampacity of Conductor 5Z8A It 10 �5 tcb /,go see Table 310 �5fB)(3)(o), TiOle 310 15�B:)�3)(a) �andMlck-100 The temperature factor for 90°C insulation at WC is 0.96 The fill factor for a conduit/cable that has 2 wires is 1. The ampacity derated for Conditions of Use is the product of the conductor ampacity (55KI multiplied by the temperature factor (0.96) and by the fill factor (1). 55A X 0,96 X I = 52.8A r----------------------------------------------------- I D. Max Current for Terminal Temp. Rating 50A see 110 14(c) The lowest temperature rating for this conductor at any termination is 75°C. Using the method specified in 110. 1 4(C), the maximum current permitted to ensure that the device terminal temperature does not exceed its 75°C rating would be the amount referenced in the 75°C column in Table 310.15(B)(16), which is 50A. =E�.Minimum Allowed OCPD Rating 41A ,4 se-- 240,4 NEC 690.9(B) requires that the OCPD be rated for no less than 1.25 times the Continuous Current of the circuit. 32.75A X 125 = 40,94A F. Minimum Required EGC Size 10 AVyC see Table 25/J 122 The smallest EGC size allowed is 10 AWG for OCPD rating 50A according to Table 250.122. G. Minimum Recommended Conduit Size 0,7 see 3C141T The total area of all conductors is 0.1309in', With a maximum fill rate of 0.4, the recommended conduit diameter is 0,75. T e4 Des-ch ton sizeArea Q E8AWG Totd Area 2Conductor TFWN-2 0.0366n' 0,0732t1 Neutral 8 AWG THWN-2 0,0366in' -I 0,0366irf I I E WornentGround 10AWG THWI-2 0,0211in' 0.0211in' 1309iff 0. 1 309in' / 0A = 0.3273in' (Corresponding to a diameter of O. 75') Fundamentally Diffferent. And Beater.., mm i c Y-V A u nVV si n c i a,,o c F i �, g� ( A soiullw df,,�ignedl, engineprEd, and war -anted by one Maximum Pwower. Minimalist Design. SON �. r}s , e7i Highest Lifetime Energy and Savings, 1 M 22 Xear's of oiler"*don Best Reliability, Best'Oiarranry Yea rs of o'apcE'a:Tb n LISTED �m $$gg ILP I i C3, C, or, ILI, 111 11 Ii.); 1" lit! 511 01 (X-1Q-AM1-240-3) LISTED To learn more about Enphase offerings, visit enphasexom 1-he IQ Cornb0-�er 3-" Mtn Enpnase IQ Efwoy' onsolidates interconnection -quir)-ment into a sinde endosurr__ QF01 streart dine s PV and storage installations by ,providing a corlsistent, pre -wired Solution fol- esic"ential applications. It offers UP W 70i_r 2-pole inCut circuits and Eator, EIR series busbar assernbly, Smart Includes IQ Envoy for communication and contiol Flexible networking supports VQ-Fi, Ethernet, or cellular Optional AC receptacle available for PL bridge Provides production metering and optional consurnittion monitoring Reduced size from previous cory-IbineF Centered morwiting brackets support single surd nnounting Supports back and side conduit en1I y Up to four 2-pole tnanch circuits for 240 VAC plug-in breakers (not inciudded) 80 A total PV or storage branch circuils Diii-rbieNF�TL-certif�edNEMAtypp- 3R enclos=­rre Five-year erarranty UL fisted r�- ENPHASE. Enphase IQ Combiner 3 MODEL NUMBER iQ Conibiner 3 AIQ-AM'1-240-3 IQ Combiner 3 with Eriphase IQ Envoy" prinoolcirca rtboard for integrated oavarrue grade pry ., 2,5%), production metering (ANSi C12,20 O.5%) and ciptionall, consumption monitaring 0-1 i- ACCESSORIES and REPLACEMENT PARTS 11rot fricluded, order sepafately) Enphase lalobiie ConnetrV- CELLMODEM -103 (4G / 12-year data plan) Plug and play industrial grade celludaf­ modern xith data plan for s.stem neuic to 60 CELLIVIODEM-01 (3G i 5-year data plan) n, microinverters. i(Availablelthe US, Canada, kiexico, Puerto Rico, andthp US Vfrgin islands, GEWAOD0,11- Iol iAA �aoeLT d EZ,I' 5-ye,8 r da-ta pla vibere there is adequaie ce'lluiar service in't-of installation area,) ConaUmfuion Monitoring' CT OT-2jO SPLIT Split core current transiormers enablefohole horrre crfrouniplirn rrg­,eing (,I' - clip uit Breakers Supports Eaton 11R210BR215, BR220, BR230, BR240, BR250, and BR260 cifouit breawars. E iPK10A,2-,2_40 Circuit breaker, 2 pole, 10A, Eaton BR210 EIRK-15A.2-240 chroult breaker, 2 pole, 15A, Eaton BR215 BRK­2GA-2P­240 Cicuit breaker, 2 pole, 20er; rortor,, BR220 EPLC-01 Power line carrier (communroallion bridge pair), quartiTy 2 XA-PLUG-120-3 Accessory receptaole for Prove, Live Carriat to IQ Combiner, 3 (required fix EPLO-01) XA-ENV-PC8A-3 Replacernent IQ Envoy phInted cimuit boand IPCB) to, Cfvrnbinler 3 ELECTRICAL SPECIFICATIONS Rating Continuous duty syste'm vortage 120(240VAC, 60 Hz Eaten BR series bwsba� , sting 125 A rvla X. co n � i n; a U s C U, ' r e ,, 1, , a, -, � r, g 10 rI 1 p �; 'I, to g r I cl) 65 A Ifflax, froor/cirvuit a`ing (woput) 90A B-oric', cirouits Isolar and/or storpge) Ulp to four 2-pofe Eaton BR series Distributed GfvrnrraTirf7 fDG) be - akers oIv'r at included) 1'rilax, confln"jou's cull"slrna (input from PV) 64A ax. troal branch circult breaker sting Orfput) M r 80A of distributed generation / 90A wit h IQ Envoy breaker lncl,,,ded Production Metering CT 200 Asolid cixe preinstalledand ofiredlo rQ Envoy MECHANICAL DATA Dimension,s 'WxHxD,, 49.5 x 37,5 x 16,8 or- ,19,5'x 14,75' x 6.63'). Height if� 21,1.6 (53,5 vmfevrth rriounting brPciets), WeI ght 7_5 kg,16,1 lits) I yfiri1sent tarrrperavure w e-400 Cto+460 G(401W 1151 F1 Cooling Natural convection, plus heat shield Enclosure eI--,virorrmwtuql,aong outdoor, NRTL-cei tified, NEMA t,,qw, 3R, polynarbonale construclIhot wife Sizes 20AW10Abrearrerin'Tuts: 14to4AWG,,�oi.,,pecoal curs 60 A breaker branch input: 4+ol/r,,AWGcopper co=id,,-,,o',�5s Main hugcorntsnedoutpui. Neitralandground: 14iol/Ocoppeductore Always foilow local code requirements for rronduc_lrx sizig, Aftiwds To 2000 meters (6,560 feet, INTERNET CONNECTION OPTIONS integrated Voi-Fi 802,11b/g/n rtheInro Optional, 802.3, CatHf,rfi Cat 6) U FP Elhemet Gai)le Into Cellular Optional, CELLIVICIDEM-01 (QG) orCELf .140DENI-03 (4GI or GIELLIAODEM-NI (AG based LTE-M) (not included) COMPLIANCE COntpliotrice, Combiner UL 1741 CANI C22 2 Nry 1071 47 CFR, Fdis' 15, Class 6, ICES 003 Production metering: ANSI C12,20 accuracy c�ass 0-5 (Pyr prOducoori) Cornpijannc, 10 Envoy UL 60601-1/CANf0SA 22,2 No. (510 10-1 Consumption monitod,ti iG,elair ed for Erprrase Storage Systems, To learn rnore about nphase offerings, visit enphase.com ENPHASE. RSTC Enterprises, Inc. 715-830-9997 Outdoor -o Photovoltaic n i, ; os Composition/Cedar Roof System ETL listed and labeled • UL50 Type 3R, 11 Edition Electrical equipment enclosures 0799 Series Includes: 0799 - 2 Wire size 210-14 0799 - 6 Fire size 14-6 0799 - D ilVire size 14-8 Models assailable in Grey, Black or Stainless Steel Material options: • Pomder coated, 18 gauge galvanized 90 steel (1,100 hours salt spray) • Stainless steel Process - Seamless draw (stamped) Flashing - 15.25" x 17.25" Height - 3" Cavity - 255 Cubic inches 0 Fastened to base using toggle fastening system 5 roof deck knockouts i Knockout sizes: (3) .5°, (1) .75" and (1) 1" 0 8", 35mm slotted din rail 9 Ground Block Passthrough and combiner kits are available for either AC or DC applications. LADECK FLASHED 5 ROOF -MOUNT COMBIN £a S U E r'^^ F�T*N Powering Business Worldwide Eaton general duty cartridge fuse safety switch #1 IfflI_ � alp C:782113144221 Dimensions: • Height: 14.38 IN ® Length: 14.8 IN • Width: 9,7 IN UCFU� Notes:Maximum hp ratings apply only when dual element fuses are used. 3-Phase hp rating shown is a grounded B phase rating, UL listed. Warranties: Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first. Specifications: * Type: General duty, cartridge fused * Amperage Rating: 60A * Enclosure: NEMA 3R * Enclosure Material: Painted galvanized steel * Fuse Class Provision: Class H fuses * Fuse Configuration: Fusible with neutral * Number Of Poles: Two -pole * Number Of Wires: Three -wire * Product Category: General duty safety switch * Voltage Rating: 240V Supporting documents: * Eatons VoUre 2-Commercial Distribution * Eaton Spedficafion S"leet - DG�222NRB pe.eatc-,n.com Product compliance: No Data qD 2016 Eaton. All rights reserved, ell, X, V s I IL"s Jii 9 To learn more about Eriphase offerings, visit enphase.com The high-powered smart grid -ready 7X dramatically simplifies the installation process while achieving the highest system efficiency for systems with 96-cell modules, Part of the Enphase IQ System, the IQ 7X Micro integrates with the Enphase IQ Envoy"", Enphase IQ Battery", and the Enphase Enlighten" monitoring and analysis software. The IQ Series Moroinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, enabling Enphase to provide an industry -leading warranty of up to 25 years. Lightweight and simi ' p I a Faster installation vvith irnproopd, lighter too wife cabling Built in rapid shuldown cornpharn (NEC 2014 & 2017) Efficient and Reliable Orrtirdzed flsr high poelvered 96 c-pil" rnodules Highest CEC efficiency of 975% Male than a rniflion hours of testing Class 11double-insulared enclosure UL listed Compliesevith advanced grid su.ppcerT, voltage and frew,uency ride -through iecluirerensints Remotely updates to respond to changing grid requirements Configurable for varying grid profiles Meets CA Rule 21 hJL 1741 -SAJ ' Tne rQ !X is icqkj�red �c supporr 9,-(eell rreredelles, ENPHASE. Enphase IQ 7X Microinverter INPUT DATA (DC) M7X-96-2-US and 1Q7X-96-B-US Ceornmonly used module pairings' 320 W - 460 W + Module compatitolity 9& call PV Modules maximuns inpul Devoltage 79,5 V Peak. rovve�'ca king vollage 53 V - 64 V I C operatin 9 rarl g ls 25V-79.511 tM 'nlmax STart ioftage 33 V / 79.5 V Mox DC: shror circuirent (flaodule Isc) 10A overvoliage class D' par, !I DO pw t backfeled crerrt 0 A revarray configuration 1 a 1 ungrounded array' No additional DC side prolection IBC side proteotion requires max 20A per beancl, cr-ceeil fleaK onto povier. uZU VA Vo, lucerninai g.-L),soltagpefrarege'e 240V / 211-264 V 208 V/ 183-9-79 V to a x i mu rn c ont i n u o u a is u, p u 1, C re r, e re t 1 31 A (240 VAC) 1-51 A(208`VcVC) Nominal firequency 60 Hz Exelreded free Pricy range, 47 - 68 Hz AC short circuit fault cufrent over 3 cyclea 5,8 Arms rsaxini,,lar uriiie pe, 20 A fL-Lbe one!, i circrift' 12 (240 VAC) 10 e20 8 VAC) Gvervieftage ciassr AC part M AC par,, bar vf ad, 18mA povve, 'Is star settir", g 11'0 Power faor ladjusiable) 0.85 leading... 0.85 lagging EFFICIENCY @240 VAC @208 VAC CEG weighted efficienay 97.5 y, 97,0% MECHANICAL DATA lelt te'n1perature range, -40sC to +600C Reladveilurnkfity range 4% to 100% (condensing) cor"neccortype (1Q7X-96-2-US) f4C4 (or Arriphenol H4 UT X with orstiesnal Q-DjCC-5 adapter) Coil reercol type tIQ7X-96- BAJIS) FrreJlds PV2, ntay require adap! era for modi,deS Wle`f,4r14 or rj T X connerto,s: PV2 to M04: order ECA-S20-S22 PV2 to UTX: older ECA-S20-S25 Dimensions (,WxHxD) 212 mitts a 175 nim x 30,2 rnm (without bracket) suiogirt 1 -08 kg 1(2,38 lbs) Cowling Naturalconevection - No fans App,owid for we, loca-,,rons Yes PcMufil,n degree PD3 Encktsue ass';I double -insulated, corrosion -es boant pvlymerjo encros—,,e Environmental category/ UV exposure ratjng NEMA Type 6 i outdoor FEATURES 64irr'o 'u'llica Lion, Par w, er Li neCo mmunication PLC) Monitoring Enlighten Manager and MyEnllgMeri monitoeing rels-flons Compatible with Enphase IQ Envoy Disconnecting maoins, The AGaice? DC cm-erictors have beer, evaluated and approved by UL for use as the fived-break disconnnett required by NEC 690. compflance i✓A Rule 21 (UL 1741-SA) JCES- 00030rasaEl, CAN/C&A-'22,2 NO, 107,1-01 Trds product is UL Listed as PV Rapred Shut loco. Equipmentand corefrierneeivJere: NOC-2014 and NEC-2017 section 690.1" and 022,1-2015 Rule 64-218 Rapid Scudown of PV Sys-, for AC and DC conductors, whIn installed act rlditreg rnae,,ufar-.urer's jils'Fl U I CIP✓`,S. a el"ofrso DC /AC rain trie c oln,p at I bty -al or al hl!P I'du2,P - cog, fl)lx�­_U._'r,,`!,.r 'Unlor. `2Ma 2 Nreenitiil doeleole rarege can be exte,­d1,,d ueyonell rommal If required bylehe urlily, 3�mi,rL may,ary. Refieto lol',a; feq-,irements to define IM, nuniber of r6croinvorters FeF asee in oiji area, T 'earn I I ­ mcne about Enishase offerings, visit enphase.com ENPHASE. je� Ar' e IRONRIDGE Flush Mount System IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 25-year warranty. Strength Tested structural performance, Class A Fire Rating rating of the existing roof, UL 2703 Usted System Entire system and components meet newest effective UL 2703 standard. Pre -stamped engineering letters available in most states, Design Assistant RNOW-AILAIRS RUNS a 25-Year Warranty of impairing defects. rAfflum A low -profile mounting rail for regions with light snow. 6'spanning capability Moderate load capability Clear and black finish Universal Fastening Objects bond modules to rails. Fully assembled & lubed Single, universal size Clear and black finish Flash and mount XR Rails with superior waterproofing. Twist -on Cap eases install Wind -driven rain tested Mill and black finish solar mounting rail. 8'spanning capability Heavy load capability Clear and black finish into a bonded end clamp. Bonds modules to rails Sized to match modules Clear and black finish Flash and mount conduit, strut, or junction boxes. Twist -on Cap eases install Wind -driven rain tested A heavyweight mounting rail for commercial projects. 12'spanning capability Extreme load capability Clear anodized finish Bond modules to rails while staying completely hidden. Universal end -cam damp Tool -less installation Fully assembled gg­_'- Or 71"1, '-s-, gm 5> Drop -in design for rapid rail attachment. Secure rail connections Slat for vertical adjusting Clear and black finish All rails use internal splices for seamless connections. * Self -drilling screws ® Varying versions for rails ® Forms secure bonding r;R Connect arrays to equipment ground. Low profile Single tool installation Mounts in any direction Bonding Hardware agz�� AM 'a: Bond and attach XR Rails to roof attachments. T & Square Bolt options Nut uses 7/16" socket Assembled and lubricated . . . . . . . . . . . . . . Design Assistant NABCEP Certified Training Go from rough layout to fully Earn free continuing education credits, engineered system. For free, while leaming more about our systems. 28375 Industrial Blvd. 28375 Industrial Blvd. Hayward, CA 94545 Hayward, CA 94545 1-800-227-9523 1-800-227-9523 IRONRIDGE lronRidge.00rn IRONRIDGE lronRidge.com Attn: Corey Geiger, COO, lronRidge Inc. Date: May 181h, 2020 of the letter shall be read in its entirety before being applied to any project design. The Flush Mount System is a proprietary rooftop mounting system used to support photovoltaic (PV) modules installed in portrait or landscape orientation and s6t parallel to the underlying roof suKace. PVmodules are supportad by txtruded alumin*m XR Mails and secured to the rails with lronRidge mounting clamps, The XR Rails are side mounted to a selected roof attachment with Exhibit EX-=5, 0 ASCE/SEI 7-10 Minimum Design Loads for Buildings and Other Structures (ASCE 7-10) 6 2015 International Building Code (IBC-2015) 9 Florida Building Code 6th Edition (2017) Building 0 2015 Aluminum Design Manual (ADM-2015) The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for the respective loads and configurations listed, covering wind exposure categories B, C, & D, roof zones 1, 2 & 3, and roof slopes from 81 to 451, The span tables are applicable provided that the following conditions are met: 1. Span is the distance between two adjacent roof attachment points (measured at the center of the attachment fastener) Z The underlying roof pitch, measured between roof surface and horizontal plane, is 45" or less. 3. The mean roof height, defined as the average of the roof eave height and the roof ridge height measured from grade, does not exceed 30 feet. 4. Module length shall not exceed the listed maximum dimension provided for the respective span table and module width shall not exceed 42". 5. All Flush Mount components shall be installed in a professional workmanlike manner per lronRidge's Flush Mount installation manual and other applicable standards for general roof construction practice, 02020 ImnRidge, Inc, FL Flush Mount System Certification Letter - I The span tables provided in this letter are certified based on the structural performance of IronRidge XR Rails only with no consideration of the structural adequacy of the chosen roof attachments, PV modules, or the underlying roof supporting members. It is the responsibility of the installer or system designer to verify the structural capacity and adequacy of the aforementioned system components in regards to the applied or resultant loads of any chosen array configuration. Sincerely, Gang Xuan 2020.05.22 '00'07- 120-32,010 Gang Xuan, PE Senior Structural Engineer This item has been etectronicaffy signed and seal by Gang Xurm using a Digital signature and date. Printed copies of this document are not considered signed and seated and the signature must be verified on any electronic copies. FL Flush Mount System Certification Letter - 4 28357 Industrial Blvd, 28357 Industrial Blvd. Hayward, CA 94545 Hayward, CA 94545 IRONRIDGE 1-800-227-9523 lronRidge,com IRONRIDGE lronRidge.00m Attn: Corey Geiger, COO, fronRidge Inc. Date: July 11�, 2021 This letter addresses the structural performance and code compliance of fronRidge's Flush Mount System. The contents of the letter shall be read in its entirety before applying to any project design. The Flush Mount System is a proprietary rooftop mounting system used to support photovoltaic (PV) modules installed in portrait or landscape orientation and set parallel to the underlying roof surface, PV modules are supported by extruded aluminum XR Rails and secured to the rails with fronRidge mounting clamps. The XR Rails are side mounted to a selected roof attachment with 3/8" stainless steel bonding hardware and then attached directly to the roof structure or to a stanchion that is fastened to the underlying roof structure. Assembly details of a typical Flush Mount installation and its core components are shown in Exhibit EX-001 5, listed below, for the load conditions and configurations ta ulated in the attached span tables. * ASCE/SEI 7-16 Minimum Design Loads for Buildings and Other Structures (ASCE 7-16) * 2018 International Building Code (I BC-2018) * 2020 Florida Building Code (FBC-2020) * 2015 Aluminum Design Manual (ADM-2015) ® Report SEAOC (Structural Engineer Association of California) PV2-2017 Find Design for Solar Arrays The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for the respective loads and configurations listed, covering wind exposure categories B, C, & D, roof zones provided in ASCE 7-16 for gable & hip roof profiles, and roof slopes of 8' to 45'. The tabulated spans are applicable when the following conditions are met: 1. Span is the distance between two adjacent roof attachment points (measured at the center of the attachment fastener). Z Each module shall be supported by 2 rails (2 rail system) or 3 rails (3 rail system). Spans are calculated based on 2 rail systems, and conservatively deemed acceptable for 3 rail systems. 3. The underlying roof slope, measured between the roof surface and horizontal plane, is 81, to 450. 4, The mean roof height, defined as the average of the roof eave height and the roof ridge height measured from grade, does not exceed 30 feet, 5. A clearance from the underside of the array to the roof surface of 2" minimum shall be provided and the height of the array, the distance from the module top surface to the roof surface (defined as h2), shall not exceed 10'. consideration of the structural adequacy of the chosen roof attachments, PV modules, or the underlying roof supporting members. It is the responsibility of the installer or system designer to verify the structural capacity and adequacy of the aforementioned system components in regards to the applied or resultant loads of any chosen array configuration, Sincerely, Gang Xuan'tG y"r" 1, —E b AXdS This item has been signed and seat by 60.9 Xu.. No 8os'49 using . Digital signature and data. Printed copies of this docu- 2021.07.14 considered signed and seated and tbe signature must be Ve'l on any electronic copies, '00'07- 17-002-025 Gang Xuan, PE Senior Structural Engineer 02021 lronRidge, Inc, FL Flush Mount System Certification Letter - 1 C2021 fronRidge, Inc, FL Flush Mount System Certification Letter - 4 r Insert Frameless Kit T-bolt in top rail slot. Place star washer over T-bolt, allowing it to rest on top of rail, Secure Star ftsher module clamps with a hex nut and torque to 80 in-ft. 9 Tested or evaluated module clamps: Suntorson silver or black SFS-UTMC-200(B) mid and SFS- UTEC-200(B) end clamps. Sunpreme, silver or black mid and end clamps with part numbers 75MI05)(where 'X" is 1, 5, 6 or 7. lronRidge silver or black mid and end clamps with part numbers FMLS-XC-001-Y where 1)(" Is E or M and "Y" Is 8 or blank. the module clamps. 9 Frameless modules require using a Grounding Lug on every rail. <_ Module Clamp (80 in-lbs) Grounding Lugs Required on Every Rail otherwise noted, 'xx)(' refers to the module power rating and both black and silver frames are included in the certification Amerlsolar Amerisolar modules with 35, 40 and 50 mm frames AS-bYxxxZ Where "b"can be 5 or 6; "Y" can be M, P, M27, P27, M30, or P30; "xxx" is the module power rating; and 'Zoan be blank, W or WB Astronergy modules with 30, 35, 40 and 45 mm frames aaSMbbyyC/zz-xxx Where "as" can beCHor Astronergy Solar A- "bb" can be 60,66, or 72; "yy' can be blank, 10 or 12; "C" can M, P, M(BL), M-HC, M(BL)-HC, P-HC, 'zz" "xxx" (DG), or (DGT); can be blank, HV, F-B, or F-BH ; and is the module power rating Astronergy frameless modules CHSM6610P(DG)-xxx Where "xxx" is the module power rating Auxin Auxin modules with 40 mm frames AXN6y6zAxxx Where "y"can be M or P; 'Y' can be 08, 09, 10, 11, or ------------ 12; "Acan be F or T,' and "xxx" is the module power rating . .. ..... Axitec Modules with 35 and 40 mm frames AC-xxxY/aaZZb Where "xxx" is the module power rating; oy" Axitec can be M, P or MH; "aa" can be blank, 125- or 156-; "ZZ' can be 54, 60, 72,120, or 144; "b" can be S or SB Bovial Boviet modules with 40mm frames BVM66aaYY-xxx Where "aa" can be 9, 10 or 12; "YY" is M or P; and "xxx" is the module power rating BYD Where "xxx" is the module power rating; "Y" can be M, P or MH; "aa" can be blank, 125- or 156-; "ZZ" can be 54, 60, 72, 120, or 144; "b"can be S or SB Canadian Solar modules with 30, 35 and 40 min frames CSbY-xxxZ Where "b" can be 1, 3 or 6; "Y" can be H, K, F, U, V, W, or X; "xxx" refers to the module power rating and "Z" can be M, P MS, PX , M-SD, Canadian Solar P-AG, P-SD, MB-AG, PB-AG, MS -AG, or MS -SD Canadian Solar frameless modules CSbY-xxx-Z Where "b" can be 3 or 6; "Y" is K, P, U, or X; "xxx"" is the module power rating, and "Z'can be M-FG, MS-FG, P-FG, MB-FG, of PB-FG CertainTeed CertainTsed modules with 35 and 40 frames CTxxxYZZ-AA Where "xxx" is the module power rating; "Y" i can be M, P or HC; "ZZ' can be 00,01, 10, or 11; and "AA!'can be 01, 02,03 or 04 CSUN Csun modules with 35 and 40 mm frames YYxxx-zzAbb Where "YY" is OSUN or SST, xxx is the module power rating; "zz"is blank, 60, or 72; and "A"" is blank, P or M; `bb" is blank, BB, BW or ROOF Ecosolargy modules with 35, 40 and 50 mm frames ECOxxxYzzA-bbD Where "xxx"' is the module power Ecosolargy rating; "Y" can be A, H, S, or T; "zz" can be 125 or 156; "A!can be M or P; "bb"can be 60 or 72; and "D" can be blank or B J. ET Solar modules with 35,40 and 50 mm frames ET-Y6ZZxxxAA Where "Y' can be P, L, or M;'ZZ' ET Solar can be 60 or 72; "xxx' refers to the module power rating; and "AX can be WB, WW, BB, WBG, WWG, WBAC, WBCO, WWCO, WWBCO or BBAC Flex modules with 35, 40 and 50 mm frames and model identifier FXS-xxxYY-ZZ; where "xxx" is the Flex module power rating; "YY" can be BB or BC; and "ZZ'can be MAA1 B, MAA1W, MA81W, SAA1 B, SAA1 W, SACI B, SAC1 W, SAD 1 W, SBA1 B, SBAI W, SBC1 B, or SBC1 W GCL GCL modules with 35 mm and 40 mm frames GCL-a61YY xxx Where "a" can be M or P; "YY" can be 60, 72, or 72H; and xxx is the module power rating GigaWatt Solar Wx Gigawatt modules with 40 mm frames GxxYY Where 'xxx" refers to the module power rating; and "YY" can be either PB or MB Hansol 'Hansol modules with 35 and 40 frames HSxxxYY-zz Where "'xxx" is the module power rating; "YY" can be PB, PD, PE, TB, TD, US, UD, or UE; and "zz" can be AN1, AN3, AN4, HV1, or JH2 Hanwha Solar modules with 40, 45 and 50 mm frames HSLaaP6-YY-1 -xxxZ Where "aa" can be either Hanwha Solar 60 or 72; "YY" can be PA or PB; "xxx" refers to the module power rating; and "Z' can be blank or B Hanwha Q CELLS Modules with 32, 35, 40 and 42mm frames and model identifier aaYY-ZZ-xxx where "aa" can be a or B.; "YY" can be PLUS, PRO, PEAK, LINE PRO, LINE PLUS, or PEAK DUO; and "ZZ'can be G3, G3. 1, G4, (34, 1, L-G2, L-G2,3, L-G3, L-G3. 1, L-G3y, L-G4, L-(34,2, L-(34y, LG4.21TAA, Hana 0 CELLS BFR-G3, BLK-G3, BFR-G3.1, BLK-G3.1, BFR-G4, BFR-G4,1, BFR G43, BLK-G4.1, G41SC, G4.1/sC, wh G4,1/TAA, G4.11MAX, BFR G4,1/TAA, BFR G4.1/MAX, BLK G4.1/TAA, BLK G4,1/SC, EC-G4,4, G5, BLK-G5, L-G5, L-G5.1, L-G5.2, L-G5.2/H, L-G5.3, G6, G6+, BLK-G6, L-G6, L-G6.1, L-G6,2, L-G6.3, G7, BLK-G6+, BLK-G7, G7.2, G8, BLK-G8, G8+, BLK-G8+ L-G7, L-G7,1, L-G7.2, L-G7.3, L-G8, L-G8.1, L-G8.2, or L-G8.3; and "xxx"is the module power rating Heliene Heliene modules with 40 mm frames YYZZxxx Where "YY" can be 36, 60, 72, or 96; "ZZ" can be M, P, or MBLK; and ")(x)e' is the module power rating HT-SAAE modules with 40 mm frames HT72-156Z-xxx Where "Z'oan be M, P, M-C, P-C, M(S), M(VS)' HT-SAAE M(V), P(V), M(V)-C, P(V)-C; and 'xxx" is the module power rating Hyundai modules with 33, 35, 40 and 50 min frames HiY-SxxxZZ Where "Y" can be A, M or S; "xxx" Hyundai refers to the module power rating; and "ZZ'can be HG, HI, KI, MI, MF MG, Rl, RG(BF), RG(BK), SG TI, or TG Itek Itek Modules with 40 and 50 mm frames IT-xxx-YY Where "xxx" is the module power rating; and "YY" can be blank, HE, or SE, or SE72 - ----------- JA Solar modules with 35, 40 and 45 mm frames JAyyzz-bbx/ea Where "yy" can be M, P, M6 or JA Solar P6,"zf'can be blank, (K), (L), (R), (V), (BK), (FA), (TG), (FA)(R), (L)(BK), (L)(TG), (R)(BK), (R)(TG), (V)(BK), (BK)(TG), or (L)(BK)(TG); "bb" can be 48, 60, or 72; "ww"can be S01, S02, S03, S09, or S1 0; xxx" is the module power rating; and "aa" can be MP, SI, SC, PR, 3BB, 4BB, 4BB/RE, 5BB ---------- Jinko modules with 35 and 40 mm frames JKMYxxxZZ-aa Where "Y" can either be blank or S; "xxx" is the module power rating; "ZZ"can be P, PP, M; and "aarcan be blank, 60, 60B, 60H, 60L, 60BL, 60HL, Jinko '60HBL, 60-J4, 60B-J4, 60B-EP, 60(Plus), 604, 60-MX, 72, 72-V, 72H-V, 72L-V, 72HL-V or 72-MX Jinko frameless modules JKMxxxPP-DV Where "xxx" is the module power rating Kyocera Modules with 46mm frames KYxxxZZ-AA Where "Y" can be D or U; "xxx" is the module power Kyocera rating; "ZZ'can be blank, GX, or SX; and "AA" can be LPU, LFU, UPU, LPS, LPB, LFB, LPBS, LFB2, LPB2, 3AC, 3BC, 3FC, 4AC, 4BC, 4FC, 4UC, 5AC, 5BC, 5FC, 5UC, 6BC, 6FC, 8BC, 61VICA, or 6MPA LG modules with 35, 40 and 46 mm frames LGxxxYaZ-bb Where "xxx" is the module power rating; "Y" LG can be A, E, N, 0, S; "a" can be 1 or 2; "T can be C, K, T, or W; and "bb" can be A3, A5, B3, GS, G4, K4, or V5 Longi modules with 30, 35 and 40 mm frames LRa-YYZZ-xxxM Where "a" can be 4 or 6; "YY" can be Longi blank, 60 or 72; "ZZ' can be blank, BK, BP, HV, PB, PE, PH, HBD, HPB, or HPH; "xxx" is the module power rating Mission Solar modules with 40 mm frames MSEbbxxxZZaa Where'bb" can be blank or 60A; "xxx" is the Mission Solar i module power rating, "ZZ'can be blank, MM, SE, SO or SO, and "aa" can be blank, 1J, 4J, 4S, 5K, 5T, 6J, 6S, 6W, 8K, 8T, or 9S Mitsubishi Mitsubishi modules with 46 mm frames PV-MYYxxxZZ Where "YY" can be LE or JE; xxx is the module power rating; and "ZZ' can be either HD, HD2, or FB q ,%Y:. '//. J ///�i` i"/ � ter. % ram' .l //a/..�/„✓. r �f " frI' /�;''�//,,. '✓ /,r /i /r. / 'r//%.,',� .-.rr,,,r r-. .'-r r:..' , ./// % �,..r, '=%.,.' ,'!, f r/... f / /-:. �f/l/.':�f%ffl;/IO �'% .// .I'll// / .. �, lr/ �/?✓,1 -1 //r /ll/ �f/' ,l ✓ . r / / r„rr,,..r r. .,:.. ✓r✓/, ....... ✓....., ✓,:. /: r.,.wrGe,.../ ,,,/.., , l,� F,p/ .��. r, r�%! l,_./✓ /.,,/,,,,o� ��,,., /l,+S f,"',,,!a,,, :. �:. /, ._✓ri-.c: , L ,,.=o ,„�;�..i. Motech �,,.. .,. ,,, IM and XS series modules with 40, 45 and 50 mm frames ,-,2 v ... ...�. o Solar Power modules with 35 mm frames D6YxxxZZaa Where "Y" can be M or P; xxx is the Neo Solar Power module power rating; " can be 133A, B4A, E3A, E4A, H3A, H4A; and "aa!'Can be blank, (TF), 9 p NQ ME or ME (TF) ~BH Panasonic modules with 35 and 40 mm frames xxxYYzzA Where "xW' refers to the module Panasonic ; power rating, "YY" can be either KA, SA or ; " „ can be either 01, 02, 03, 04, 06, 06B, 11 11 B, 15, 15B, 16, 16B, 17, or 18; and "A"can be blank, E or G Pelma# Palmer modules with 40 mm frames SGxxxYzz Where "xxx" is the module power rating, °Y" can be z M or P; and "zz" can be blank, (BF), or (FB) Phono Solar Phono Solar modules with 35, 40 and 45 mm frames PSxxxY--ZZiA Where xxx refers to the module <- power rating; "Y" can be M or P; "ZZ"' can be 20 or 24; and "A" can be F, T or U Prism Solar Prism Solar frameless modules BiYY xxxBSTC Where "YY" can be 48„ 60, 60S, 72 or 72S; and "xxx is the module power rating REC modules with 30,38 and 45 mm frames RECxxxYYZZ Where "xxx" is the module power REC Solar rating; "YY" can be AA, M, NP, PE, PE72, TP, TP2, TP2M, TP2SM, or TP2S; and "ZZ" can be blank, �,..,,... ..,..,. Black, BLK, BLK2, SLV or 72 ..rr. _„r.,,, ReneSo#a modules with 35, 40 and 50 mm frames JCxxxY-ZZ Where "xxx" refers to the module Rene la power rating; "Y" can be F, M or S; and " can be Ab, Ab-b, Abh, Abh-b, Abv, Abv-b, Bb, Bb-b, Bbh, Bbh-b, Bbv, Bbv b, Db, or Db b . b, , _., Renogy Renogy Modules with 40 and 50 mm frames R€G-xxxY Where ``xxx" is the module power rating and"Y"can beDorP . ..... _ .... Risen Modules with 35 and 40 mm frames RSMyy-6-xxxZZ Where "yy" can be 60 or 72; "xxx is the Risen module power rating; and "ZZ" can be M or P Frameless modules RSMyy-6-xxxZZ Where "yy" can be 60 or 72; "xxx" is the module power rating; and ZZ can be MDG or PDG S Energy S-Energy modules with 40 frames ShlxxxY-ZZ Where "xxx" is the module power rating; "Y"can be "ZZ" M or P; and can be 10, or 15 Seraphim Energy Group , Seraphim modules with 3355 and 40 mm framesSEG-6YY Where "YY" n be MA, MS,PA, or "xxx" "°ZZ" PB; is the module power rating and can be BB, BW, WB or WW Seraphim USA Seraphim modules with 40 and 50 mm frames SRP-xxx-6YY Where "xxx" is the module power rating; and "YY" can be MA, MB, PA, PB, OA-XX-XX, and QB-XX-XX Sharp modules with 35 and 40 mm frames NUYYxxx Where "YY" can be SA or SC; and "xxx is the Sharp module power rating Sit€ab Si#Yab Modules with 38 mm frames SYY Z-xxx Where "YY" can be SA or LA, SG or LG, "Z" can be M, P, or X; and "xxx" is the module power rating Solaria Solaria modules with 40 mm frames PowerXT xxxY-ZZ Where "xxx" is the module power rating, "Y" n be R or C; and "ZZ" can be AC, BD, BX, BY, PD, PX, PZ, WX or WZ Solaro'ity Solarcity modules with 40 mm frames SCxxxYY Where "xxx" is the module power rating; and "YY" can be blank, B1 or B2 SolarTeoh SolarTech modules with 42 mm frames STU-xxxYY Where "xxx" is the module power rating; and "YY" can be PERC or HJT SolarWorld AG /N W SolarWorld Sunmodule Plus, Protect, Bisun, XL„ Bisun XL, may be followed by mono, poly, duo, Industries GmbH = black, bk, or clear; modules with 31, 33 or 46 mm frames SW-xxx Where "xxx" is the module power ' rating SolarWorld Americas Inc SolarWorld Sunmodule Plus, Protect, Bisun, XL Bisun XL, may be followed by mono, poly, duo, black bk or clear; modules with 33 mm frames SWA xxx Where is the module power rating Stion . Stion Thin film modules with 35 mm frames STO-xxx or STO-xxxA Thin film frameless modules .. STL-xxx or STL-xxxA Where "xxx" is the module power rating . _ �,.,. , SunEdison Modules with 35, 40 and 50 mm frames SE-YxxxZABCDE Where "Y" can be B, F, H, P, SunEdison R, or Z;"xxx" refers to the module power rating; "Z"' can be 0 or 4; "A" can be B,C,D,E,H,I,J,K,L,M, or N ; "B" can be B or W; "C' can be A or C; "D" can be 3, 7, 8, or 9; and "E" can be 0, 1 or 2 7 r j r / ' r � / r r r G ✓/':../ / / w,/ ✓ rr rr / rIM xrr'/ ✓ �'„ / ✓ ./ r r/.,(% .:: ,.,.. - „,,,.., Suniva modules with 35, 38, 40, 46 and 50 mm frames OPTxxx-AA-S-YYY Z MVXxxx-AA-S-YYY Z Suniva Where "xxx" is the module power rating; "AA" is either 60 or 72; "B" is either 4 or 5; "YYY` is either 100 101,700,1 SO, or I BI and " Z" is blank or B Sunpower standard (G3 or G4) or InvisiMount (G5) 40 and 46 mm frames SPR-Zb-xxx-YY Where Sunpower 'Z" is either A, E, P or X; "b" can be blank, 17, 18, 19, 20, 21, or 22; "xxx" is the module power rating and YY can be blank BLK C-AC AC E AC AC BLK AC or BLK D-AC Sunpreme frameless modules GXB-xxxYY Where "xxx!'is the module power rating; and "YY" can Sunp#eme be blank of SL Sunspark modules with 40 mm frames SYY xxZ ere ""YY" can be MX or ST, "xxx' is the module Suns ark p power rating and Z" can be P or W Suntech Vd, Vem, Wdb, Wde, and Wd series modules with 35, 40 and 50 mm frames Talesun modules with 35 and 40 frames TP6yyZxxx A Where "yy" can be 60, 72, H60 or H72; "Z Talesun n be M, or P; "xxx" is the module power rating; and "A" can be blank, B, or T ,. .,,, n. Trina Modules with 30, 35,40 and 46mm frames TSM-xxxYY Where "xxx" is the module power rating; "YY" can be DD05, DD06, DE14, DE15, DEG15, PA05, PCO5, PDO5, PDO6, PA14, PC14, PD14, PE14, or PE15 ; and "ZZ" can be blank, .05, ,08, ,10, A 8, ,08D, .I8D, 0,82, .002, .00S, 05S, 08S, A, A.05, A,08, A.10, A.18, A(11), A.05(11), A.08(11), A.082(11), A.10(ll), A.18(11), H, H(11), H.05(11), Trina H.08(11), .20(11), HC.20(11), or M Frameless modules TSM-xxxYY Where "YY" can be either DEG5(11), DEG5.07(ll), DEG5,40(11), DEG5.47(11), DEG14(11), DEG14C(11), DEG14C.07(11), DEG14.40(11), PEG5, PE5.07, PEG5.40, PEG5.47, PEG14, or PEG14.40 Vikram solar modules with 40 mm frames Syy.ZZ.AAA.bb Where "yy" can be M, P, MBB, MH, MS, Vikram- MHBB, or PBB; "ZZ" can be 60 or 72; "AAA" is the module power rating; and "bb" can be 03,04 or 05 Winaioo modules with 35 and 40 mm frames Wsyxxxz6 Where Y'can be either P or T; "xxx" is the Winaico module power rating; and "z" can be either M or P Yingli Panda, YGE and YGE-U series modules with 35, 40 and 50 mm frames „'ir/,,.. .,r.%r`.., ✓'.fr r.J ,� r,,,/!,c,,.. ��/,-��. f/,!%i�/r��'Jr.!��„rjI'�./r"I�i.=r', �f'k -'��.rr ff r'%'r/'r ,� ,%r �J / r'. ,r I' _.,�, ,.. The NanoMount@ Advantage The fastest roof attachment in, solar, Versatile mounting options including Gfirect-to-decking, Eliminates the need to lift shingles and prevents damage to shingle. High-Veflocity Hurricane Zone Approved - Passed TAS 100 (a) Wind -Driven Rain Test. All rnaterials are compatible with asphalt shingles and single -ply roof membranes, 5 levels of protection against water penetration Open L-Foot for fast rail attachment 360-degree positioning, serrated surface on both sides for rail mounting Aesthetically pleasing unibody aluminum cast construction Alignment markers enable easy installation SUNM*1.---'& 4 Deck Screws for D)eck Mount or 1 Lag Bolt for Rafter Mount Integrated Ultra Soft Weather Resistant gasket SunModo, Corp. Vancouver, WA_ USA * www,sunrnodo,com * 360,844,0048 o info @Dsung odo,com SUNM*&m,yfh!i�i_-"- " Part Description: Nano Rafter, Mount, Black Part No.- K50053-BKI Mnish; Block Powder Coating 2- N*rm Gm*af Material: USWR Gasket with Adhesive 3. Hex Lag Bolt M8X1 15, DIN 571,304SS N W"M MOAN I I% N"%A IMAM' WINI m ,Vnfedaf: Stainless Steel Finish: Clear 4, Sesading Washa_r,331D X_75X,1 57 Material: EPDM + Stainless Seel O1027 _`/r)Oi N,-vi—, ,6­ c­., miv, f—d D.I.h nro -bi—t 1,-, 1,qge SUNMr-imit-117- 4 f Part Description-, Nano Deck Mount, Black Part No,; K50053-BK3 to Doscripflon, �'Q I n Kit __"­__-- -­J--c Fty Deck f���y A 46,SX 76 "viz, er 2611D X -fC-X 725 1. Nono Mount Ma real: Aluminv�1111" Finish: Black Powder Coding Moferial: USWP Gasket with Adhes' e 3. Self-fopping Screvi, #63 X 76 Niaterich Stainless Steel Finish: Clear 4, Sealing "Namher .261D X,50X 125 Maferi& ROM + %intess Stee� D 102 14A/002 ""'­ ... imi", Cui"'k "­ 5­r" t" 6­'3" 'ill —'A nd;r.