Loading...
HomeMy WebLinkAbout22-3818lulty ot Zei3hwhills 5335 Eighth Street Zephyrhills, FL 33542 Phone: (813) 780-0020 Fax: (813) 780-0021 ELCMISC-003818-2022 Issue Date: 03/28/2022---i g 35 25 21 0140 00800 0210 7870 Broad Pointe Drive JN 'J'@ g, M ME g0{ 11 k7� Name: LERIANIS VEGA & PEREZ MARCU,' Permit Type: Electric Service Replacement/M Contractor: GREEN HOUSE SOLAR AN[ PEREZ Class of Work: Add/Alter Residential AIR INC Address: 7870 Broad Pointe Dr Building Valuation: $1,000.00 ZEPHYRHILLS, FL 33542 Electrical Valuation: $33,465.00 ... . ...... Phone: (813) 428-4569 Mechanical Valuation: Plumbing Valuation: Total Valuation: $34,465.00 Total Fees: $252.32 Amount Paid: $252.32 Date Paid: 3/28/2022 12:38:42PM -1 N g "OEM—M INSTALLATION ROOF MOUNT SOLAR PHOTOVOLTAIC I N "El -50, Electrical Permit Fee $2 7.32 Building Permit Fee $45.00 05= IM11= a 0 T 1�11[9 11! !11 MIRI 1 1!111! 111 I'Lli �1:11 TTTT-Tr,��� accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. �N'�+F c6NTRkfd-R s—IGNATURE *ERMIT EXPIRES IN 6 0 0 A** -a A a ttol ji guy• 14 813a80-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permitting - aaaaaaat ee aria Owner's Name VEGA, LERIANIS & LUGO, MARCUS Il owner Phone Number x 813-428-4569 Owner's Address 7870 Broad Pointe Drive Zephyrhills, FL 33540 Owner Phone Number s Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 7870 Byroad Pointe Drive Zephyrhills, FL 33540 LOT # 21 SUBDIVISION ZEPHYR LAKES PARCEL ID# 35-25-21-0140 00800-0210 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR 8 ADD/ALT SIGN o DEMOLISH INSTALL REPAIR PROPOSED USE ® SFR F-1 COMM 0 OTHER TYPE OF CONSTRUCTION F--,X-] BLOCK O FRAME STEEL DESCRIPTION OF WORK Install new roof -mounted photovoltaic solar electric system BUILDING SIZE 1900 SQ FOOTAGE 429 HEIGHT I(" I Story =BUILDING $ 33465_ VALUATION OF TOTAL CONSTRUCTION = ELECTRICAL =PLUMBING = MECHAN ICAL =GAS ROOFING Q FINISHED FLOOR ELEVATIONS AMP SERVICE O PROGRESS ENERGY = W.R.E.C. X DUKE VALUATION OF MECHANICAL INSTALLATION SPECIALTY = OTHER FLOOD ZONE AREA =YES NO BUILDER / COMPANY Green House Solar And Air, Inc. SIGNATURE 1 i'* REGISTERED Y / N FEE CURREN Y / N Address T1445160th St Clearwater FZ7760 License # I EC13011286 ELECTRICIAN �"_Uyzg- COMPANY Green House Solar And Air, Inc. SIGNATURE REGISTERED Y/ N FEE CURREN I Y/ N Address 14451 60th St Clearwater 33 0 License # I EC13011286 PLUMBER FCOMPANY SIGNATURE REGISTERED Y / N FEE CURREN Address License # MECHANICAL COMPANY SIGNATURE REGISTERED Y / N FEE CURREN Y / N Address License # OTHER COMPANY SIGNATURE REGISTERED Y / N FEE CURREN Y / N Address License If � � H � f � 6 P € � i a � � € � � I � # � � 4 # � � a # i ! a � & £ # i 7 i a ! � � # 8 E � 3 ! $ a � � 3 � � � � • I � 3 ! # 3 � i RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans wl Silt Fence installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. *`*`PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (AIC upgrades over $7500) ** Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences (Plol/Survey/Footage) Driveways -Not over Counter if on public roadways..needs ROW 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department ' NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: tithe owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/WastewaterTreatment. Southwest Florida Water Management District -Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers -Seawalls, Docks, Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency -Asbestos abatement. Federal Aviation Authority -Runways. 1 understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone "V" unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT FLORIDA JURAT (F.S. 117.03) OWNER OR AGENT _La \ (j_`4 ',•- CONTRACTOR Subscribed and sworn to (or affirmed) before me 4his Subscribe and sworn to (or affirmed befar me this w Eby by !1�.Iare personally known to me or haslhave produced Isla personally known tome r has/have produced l.-D Lv as identification.T•®_' as identification. Public "a j ♦�-� -----� - Notary Public Commission No. c;{ �i , C mmission No Name of Notary typed, printed or stamped Name of Notary typed, printed or stamped 4 8378 Foxtail Loop, Pensacola, FL 32526 1 (850)712-4219 1 chadC� gadwinen .com Too Zephyrhills Building Department 5335 80, St. Zephyrhills, FL 3354.2 Re: Vega - Residential PV Roof Mount Installation 7870 Broad Pointe Drive Zephyrhills, FL 33540 Plan Reviewer, This letter is regarding the installation of a new roof mounted Solar PV System on the existing residential structure at the address above. I have reviewed the attachment plan and have determined that the roof mounted PV system is in compliance with the applicable sections of the following Codes as amended and adopted by the jurisdiction: 2020 Florida Building Code 711, Edition, FBC ASCE 7 Min. Design Loads for Buildings & Other Structures Per 2020 FBC, the Roof Mounted PV system will be subject to the following design criteria: Design Wind Speed(V,,it) - 140mph 3sec gust, Exposure Category - C The PV System consist of the modules, railing, and connection hardware. The system will add a dead load of approximately 3 psf to the roof. The existing roof covering is Asphalt Shingle with min. 1/2" plywood decking and 2" x 4" roof trusses 24" O.C. The roofing, decking, and roof trusses are in good condition. The existing structure will be adequate for supporting the additional PV dead load and wind loads, The securement method of the PV system is to he flush mounted to the asphalt shingle roof with the Ironridge railing and the flashings/attachments. The attachments can be attached up to 48" apart in all roof zones. The mounts should be staggered, where possible, to allow distribution of the design loads evenly to the structure. The mounts shall be installed with a min. 5/16" x 4" lag screw with minimum 2-5/16" thread length. Please see attached documents and contact me should you have any questions. Sincerely, D. Chad Godwin, PE 81360 Exp.02/28/2023 Risk Category Basic Wind Speed (UR) Roof Angle Roof Type Exposure Cat. B,C, or D Mean Roof Height h Roof attachment Rafter(T'uss Spacing No. of Rails No. of Modules - Portrait No. of Modules- Landscape Module ModO Number bidg, least horizontal dim (typ.) Elevation Est, k H attachment points PV Deed Load 9 of Modules 22 Module Wm 1 45 Array W­ 994 Micro/optimizer W, 1 88 PV Pall WW „n 16 Total Weight W111mi 1098 Total Area A; 432.60 Dead Load 01.; 2.54 GC, - Uplift GC -Down p `q„(.'ft to, ��) p=q>,GC.ft )f-3) Max Allowable SRan Max Cantilever (in) II Table 1.5-1 Wind Speed (asd) mph FRC R301.2.1.3 1 ;mph Figure 26.5-1B Effective Wind Area 19.66 ftc 26,20 5 at t s Wind Directionality Ko 0.85 Table 26.6-1 Topographic factor K; 1.00 26.8 or 26.8.2 � i J Section 26.7 Ground Elevation Factor K, 1.00 Table 26.9-1 "eft Velocty Exposure Coefficient Kz 0.85 Table 26, 10-1 Array Edge Factor -r 1.50 29.4.4 'Mod�lesare convdered Ezposea in O.C. Sofa' Pane Equalization Factor 0.68 Fig, 29A-8 r1a Velocity Pressure q„ 21.75 psf q„=0.00256 KK,K,rK,V` Added Safety Factor 1,2 ? ST''v Allowable Pullout per mount 709.6 Ibs 0Ah or 0.61, 6.00 ft Flat -0.6h, Cable, Hip -0.4h n 10%of least horizontal dim 1,50 ft ft Roof Zone Set Back 3,00 ft h2 5 in Itemtn��ei e _ za.emi Module and Racking Spea 2h2 10 in Iollr1r­h1l,, itar. me ue ee a �eP Dimxmx s, LxWxH(in) 69.13 x 40.9 x 1.37 0,25 n .. ,. ...ee.. r.: i,��„�,. ar.., Iles Width 3.41 ft dl 1,00 ft rrnnromai asranm or os n e s Ibs Length 5.76 ft 12 0,25 ft a,h.-ra+. s �„ _orv.�e.. s ., Ibs Module Are 19.66 ft` 0.5h 7.50 ft a P is2r i.on,�igo Ibs Module load ratings Notes Ibs Ultimate Allowable ft' Load Rating 113.4 1 75.6 Ed Point Load =Roof Zone psf'TA load Rating -Wind(psf) -113.4 -75.6 Ed TA=(Middle Length /2)'Max So-psf b, Ed *Max span Equation,SF= Allowable pullout/Point Load tta<hment-Fesufts Eq.4 Max Span= Allowable Pullout/(SE' Roof Zone psf' L/2) Zones - Hip S' to 2W 2, 3 0/ The Max span between attachment points must not exceed the rail spans provided by racking manufacture, -1.7 -1.7 0.7 1 0.7 b) Allowable Module load ratings are determined by SF = 1.5 psf 29.4-7 psf 29.4-7 ft notes Max span' 33% Green House Solar And Air, In 813-695-9203 State Licensed Electrical Contractor EC13011286 [ Daniel Yates, license holder for Green House Solar And Air, Inc., authorize the following people to be added when registering or renewing my license and applying or signing for permits under my Florida License Number: EC13011286. Please ADD the following Agent List. This authorization letter iSvalid iDall Florida jurisdictions for one year from the date it is S|gOed, or uOU| 0y registration needs to be renewed, whichever issooner. Mark Gross Contractor's Signature Contractor's (Printed) Name: Daniel Yates I STATE OF Florida -99UNTY OF Hillsborough The foregoing instrument was acknowledged before me this 14th day of Date: 3/ 4/2O22 March 1 2022 byDaniel Yates who is personallyknto me orhas produced as identification. Notary Signature 14451 60th St. Clearwater, FL 33760 State Lic. # EC13005971 DATE: CUSTOMER NAME (hereinafter, the "Customer") 02/23/2022 Marcus Lugo ADDRESS: 7870 Broad Pointe Dr CITY, STATE, ZIP: Zephyrhills FL 33540 HOME PHONE NUMBER: WORK PHONE NUMBER: MOBILE PHONE NUMBER: (813) 428-4569 EMAIL: marcusa.Iugo@gmail.com Greer, House solar and Air, INC (the "Contractor") shall furnish all materials and perform all the work on the property address below (the "Home"): 7870 Broad Pointe Dr Zephyrhills, FL 33540 in consideration of the Contract Price listed below. WORK PERFORMED System Size: 7.92 kW Engineering, permitting, installation, inspection, and interconnection. CONTRACT PRICE The Customer shall pay the Contractor the total agreed upon sum of $33,464.79 ("Contract Price") for and in consideration of all material and labor that is provided and performed under this Sales Contract. This Contract is not contingent upon financing or other lender approval. Contractor does not provide financing but will assist Customer in securing outside financing at the specific request of the Customer in accordance with Article 23 herein. Should Customer request financing assistance, Contractor makes no warranties or representations regarding Customer's ability to secure outside financing, its terms, rates or conditions. BUYER'S RIGHT TO CANCEL. This is a home solicitation sale, and if you do not want the goods or services, you may cancel this agreement by providing written notice to the seller in person, by telegram, or by mail. This notice must indicate that you do not want the goods or services and must be delivered or post -marked before midnight of the third business day after you sign this agreement. If you cancel this agreement within the three business days clotted, the seller may not keep all or part of the cash down payment. CONSULTANT NAME/SIGNATURE: gAaZC4'r., rryp p`�� HOMEOWNER(yNAME/SIGNATURE: afr`��* ((�"/j][} 142'ce 1668d31tr 3"fS 56b6 S0a28-,7<425b8f13e-0,, Marcus Lugo JOSb 8978f2e,d7-98425ee110'61 H5253e1113s'1 ADDITIONAL TERMS & CONDITIONS: 14451G0thStClearwater FL3376O 813-695-9203 State Licensed Electrical Contractor EC13O11280 [ Daniel Yates,license holder for Green House Solar And Air. Inc., authorize the fO|kovviDg people to be added when registering or renewing my license and applying or signing for permits under my Florida License Number: EC13011280. Please ADD the followingAuthorized Agent List. This authorization letter is valid in GU Florida jurisdictions for one year from the date it is signed, or until my [egiSt[@UOO needs to be renewed, whichever iSsooner. Gail Alvarez Mark Gross Patricia Nasrallah Contractor's Signature Date: 3/14/2022 Contractor's (Printed) Name: Daniel Yates STATE OF Florida cc The foregoing instrument was acknowledged before me this 14th day of March 1 2022 by Daniel Yates who is U �� or has produced as identification. N�arySi Signature. �L INSTRd2O22068338OR BK10578 PG1678 Page l,fl Document Prepared By: 03/246022 08:48 AM Rcpt: 2433766 Rea 10.00 DS: 0.00 IT 0.00 2REENH(� L-Cs°LARAIND Aff, NG Nikki Alvarez-Sowles, Esq., Pasco County Clerk & Comptroller ME—HRR j NOTICE OF COMMENCEMENT Permit Number Tax Folio/Parcel ID: THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement: 1, Description of propeq: (legal description of property, and street address) ZEPHYR LAKES SUBDIVISION PHASES 1 A 2A 2B & 4A PB 80 PG 37 BLOCK 8 LOT 21 7870 Broad Pointe Drive Zephyrhills, FL 33540 2, General description of improvement: - Install Photovoltaic Solar Electric System 3. Owner information: a. Name and address: _Marcus Perez - 7870 Broad Pointe Drive Zephyrhills, FL 33540 b. Phone number: 813-428-4569 c, Name and address of fee simple titleholder (if other than owner): 4. Contractor: a. Name and address: Green House Solar and Air 14451 60th Street N. Clearwater, FL 33760 b, Phone number: 8136959203 5. Surety: a. Name and address: NIA b. Amount of bond $: c. Phone number: 6. Lender: a. Name and address: N/A b. Phone number: 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7, Florida Statutes: a. Name and address: N/A b. Phone number: 8. In addition to himself, owner designates the following person(s) to receive'a copy of the Lienor's Notice as provided in Section 713.13(1) (b), Florida Statutes: a. Name and address: N/A b, Phone nurnber:,­,­­­ .. .. . ... ------ .......... 9, The expiration date of the notice of commencement is one (1) year from the date of recording unless a different date is specified -­­- - - WARNING TO OWNER- ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713. PART I., SECTION 71113, FLORIDA STAI UTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVIVIENTS TO YOUR PROPERTY. A NOTOF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORETHE FIRST INSPECTION, IF YOU INTEZ!NW, TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN AFTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT, 7,gy ,ignature of Owner or Owner's Authorized Officer/Director/Pariner/Manager —STatcxs Pmted Names and Title/Office STATE OF FLORIDA, COUNTY OF Pasco The foregoing instrument was acknowledged before me by rueans of 1:1 physical presence or 11 online notarization this 22 day of Moro) Marcus Perez Owner 20 . ..... _ by of person) as (type of authority: e.g., officer, trustee, attorney in fact) for—.----- (name of party on behalf of whorn instrument was executed) who is personally known to me or who has produced , D I L as identification. -Signature of'Notory'Public Verification Pursuant to Section 92.525. Florida Statoles Notary Public state of Florida Under penatties of perjury, I declare thal I have read tnp fo,egomgand Ekaterina Linda thLit the fat-,ts siated inire 1je to tho bct of lry krovAc­ge and belief =1 1,11111My HH 2011Commi49ssion = Exp,11122/2025 Signature of Natural Person 'Signing Above 8378 Foxtail Loop, Pensacola, FL 32526 j (850)712-4219 1 chid Calocivyineng.com April 11, 2022 To: Zephyrhills Building Department 5335 811, St. Zephyrhills, Ff, 33542 ° lk Re: Vega - Residential PV Roof Mount Installation 7870 Broad Pointe Drive Zephyrhills, FL 33540 Plan Reviewer, This letter is regarding the installation of a new roof mounted Solar PV System on the existing residential structure at the address above. I have reviewed the attachment plan and have determined that the roof mounted PV system is in compliance with the applicable sections of the following Codes as amended and adopted by the jurisdiction: 2020 Florida Building Code 70, Edition, FBC ASCE 7 Min. Design Loads for Buildings &. Other Structures Per 2020 FBC, the Roof Mounted PV system will be subject to the following design criteria: Design Wind Speed(V it) - 140mph 3sec gust, Exposure Category - C The PV System consist of the modules, railing, and connection hardware. The system will add a dead load of approximately 3 psf to the roof. The existing roof covering is Asphalt Shingle with min. 112" plywood decking and 2" x 4" roof trusses 24" O.C. The roofing, decking, and roof trusses are in good condition. The existing structure will be adequate for supporting the additional PV dead load and wind loads. The securernent method of the PV system is to be flush mounted to the asphalt shingle roof with the Ironridge railing and flashings/attachments. The attachments can be attached up to 48" apart in roof zones 1, 2e, 2r, and 3. The mounts should be staggered, where possible, to allow distribution of the design loads evenly to the structure. The mounts shall be installed with a min. 5/16" x 4" lag screw with minimum 2-5/16" thread length. Please see attached documents and contact one should you have any questions. Sincerely, D. Chad Godwin, PE 81360 Exp.02/28/2023 Risk Category It Table 1.5-1 Basic Wind Speed (Ult) gure 265-1B Roof Angle RoofType@xposr rF 1a Cat. BC, rDSection 26,7 MeanRooflielghth Roof attachment ��%2S'^$�,ikCtV Rafter/Truss Sp aang C..s npL- No. of Rails No. of Modules - Portrait No. of Modules - Landscape Module Model Number bidg, east hor(t lzontai dim mp Elevation :ti`C�iP,'}t1 �; H Bt, # of,ttachma,t points PV Dead toad Module and Roc p of Modules 22 Dimensions, LxWxH (in) Module W—r 46 Ibs Width Array W,,,,as 1019 Ibs Length Micro,/optimizer W,,,1, 88 Ibs Module Area Re Rail Wrl 16 Ibs Module load Total Welght W_, 1123 lb, Total Area Ar 424.41 its Load Rating- Snow(psf) Dead Load D, 2.65 psf Load Rating- Wind(psf) Wind Speed (asd) Effective Wind Area Wind Directionality Ka To pographic factor Kn Ground E levaton Factor Ky V21DQty Exposure Coefffcent K, Array Edge Factor - Solar Pane! Equalization Factor , Velocity Pressure q,, Added Safety Factor Allowable Pullout per mount 0.41, or CAR 10% of least horizontal dim Roof Zone Set Back a hr 7.6 x 41.1 x1,57 t.43 T ft dl 63 H d2 9.29 ti O.Sh mph FRC R301.2.1.3 it, 26,20 table 26,6-1 26.8 or 26.8.2 Table 26.9-1 Table 26.10-1 29.4A I"mare cons dcretl Exposed Fig, 29,4-8 psf gn=0.00256 K,K;,K,K,V` Ibs H Flat-0.6h,Gabla,Hip-04h Hl in CL dra r r., v.,-'u Notes Eq.1 Point Load = Roof Zone Fist * TA Eq.2 TA = (Module length /2) - Max Span Ed `Max span Equation, 5F = Allowable pullout / Point Load Ed Max Span = Allowable Pullout / (SF' Roof Zone psf - L/2) o/ The Max span between attachment points most not exceed the ,it spans provided by racking manufacture b) Allowable Module load ratings are determined by SF = 1.5 EI The Contact Person should be contacted for corrections, errors, additional information, etc. Date:. 4/18/22 Contractor Name: Daniel Yates - EC 13011286 Company:Green House Solar And Air, Inc. Permit Agency: Prime Time Permits Contact Person: Patricia Nasrallah Contact Telephone: 813-695-9203 Email Address: permits@ primetimepermits.com Custome& LUGO, PEREZ MARCUS A Address: 7870 Broad Pointe Drive Zephyrhills, FL 33540 NOTES: New Photovoltaic Solar Permit Application Permit # E-LCMISC-003818-2022 Inverter Type: PV Panel: Racking: Total Wattage Roof Type: Wind Load: Fastener Type Enphase IQ7-60-2-US (22) Q.PEAK DUO BLK-G 10+ 360 Iron Ridge XR- 10 7,92OW Composition Shingle 7 to 20 Deg Use 5/16" Dia 4" Lags Z� S-1 Cover Sheet / Site Plan S-2 Detail E-1 One - Line E-2 Electrical Code S-IA Mounting Plan General Notes: -Enphase IQ7-60-2-US Micro Inverters are located on roof behind each module. -First responder access maintained and from adjacent roof. -Wire run from array to connection is 40 feet. 14451 60th Street N, Clearwater, FL 33760 844-987-6527 U First responder access Le"en S N Ground Access Z,_�, Chimney Utility Meter Satellite 0 Vent Pipe PV Disconnect I Utility Meter -COGEN Disconnect Located adjacent to Utility nneter System n1cets the requirements o1'NFPA 70th Edition, Chapter 1 1. 12 Meets All Editions of Florida Fire Prevention Code 2020 7th Edition Meets all requirements of NFPA-1 7th Edition and NFPA-101 n�IIIZT _AcCZ_!M_P=0CiwV_ Represents all Fire Clearance 1st Responder Access including Alternative methods minimum of 36" unobstructed as per Section R324 of the 2020 IRC Meets the requirements of the following- (2020 FL Residential Code & FBC, 7th Edition (2020 International Residential Code) - 2nd Printing modified by the FL Building Standards, 2020 Florida Building Energy Conservation Code 7th edition, City of Zephyrhills Code, 2017 National Electric Code.) W_ Tr Modules (2 Pitch: 20' Azimuth: 1801 Install v,111 be doge to Ma11L1fL1CtU1_1_31_ Spec MARCUS LUGO & LERIANIS VEGA 7870 BROAD POINTE DRIVE ZEPHYRHILLS, FL 33540 Layout Subject to Change Based on Site Conditions Godwin Engineering and Design, LLC 8378 Foxtail Loop Pensacola, FL 32526 D. Chad Godwin, PE Chad(�-,bgodwinengxorn Date: 3/4/2022 Drawn by: VK ikevised by: VK Mev Date: 4/8/7"f= Compass for Aerial Ironridge XR-10 General Notes: - Flashlocs are secum?k-, to roof rz-fters. 48" O.C. in Zone 1, g 48" O.0 in Zone 2e, 48" O.C. in Zone 2r & g 48" O.0 in Zone 3 using 5/16" x 4" stainless steel Lag bolts. - Subject roof has One layer. - All penetrations are sealed and flashed. Roof Section 1� Pitch Roof Rafter and Spacing R I 4/12 2 x4" @ 24 O.C. Exposure Category - C -Desigtied as per ASCE7-16 Inverter Type: Enphase IQ7-60-2-US PV Panel: (22) Q.PEAK DUO BLK-GIO+ 360 Racking: Iron Ridge XR- 10 Total Wattage: 7,920W Roof Type: Composition Shingle Wind Load: 7 to 20 Deg Fastener Type: Use 5/16" Dia 4" Lags Z/fs-le x '3/4 #4EX HEAD OOLT a/s-16 FLANGE, NU T MARCUS LUGO & LERIANIS VEGA 7870 BROAD POINTE DRIVE ZEPHYRHILLS, FL 33540 am Install will be done to MaIM111CtLIFel- Spec Godwin Engineering a Design, LLC 8378 Foxtail Loop Pensacola, FL 32526 D. Chad Godwin, PE m Chad(al),godwineng.co I 3/4/2022 VK VK C 0C 0 A Of 0 4 # 'S� A Green House Solar & Air 14451 60th Street N, Clearwater, FL 33760 844-987-6527 M 12-2 Romex can be used for interior building and attic runs only. Do not use romex in conduit or outdoor environments. ##10 AWG THWN for Home runs (I ) Line I (1)Line 2 Per Circuit =8 AWG THWN (I)EGC Inside Cie least 3/4" Conduit (tbd on site) Enphase Output Ckt Per String To Overcurrent tection Device -AC Max Output Current AC ax p * 1� Ourrent 13.3 - O ercProtection (A).25/o 0 No. of Current Carr and < Conductor Gauge AWG) 10 Enphase Total Output Ckt P p ' AC Max Output Current 22 AC Max Output Current * 125%27.5 Overcurrent Protection (A) 30 No. of Current Carrying Cond j Conductor Gauge (AWG) 10 h1Clticli112_ 010 lBbel belov, In r r ll Emergency Green House Solar & Air " 90614I • Meets 1 l .12.2. L5 Enphase IQ Trunk Cable Q-12-240 #12AWG THHN-THWN-2 UL 9703 Grounding Conductor to be bare #8 Awg NEMA 3R Junction Box �� Black - LI Red - L2 Green - Ground i RATED AC OUTPUT CURRENT. 22A NOMINAL OPERATING VOLTAGE: 240VAC Enphase Combiner Box (1) - 20A Breaker Per Circuit 2 Circuits 240V 10/15A Breaker for Envoy Disconnect Solar Combiner Box `iX-IQ-AM I -240 Photovoltaics: (22) Q.PEAK DUO BLK-G10+ 360 Inverters: (22) Enphase IQ7-60-2-US Micro Inverters Circuits: (2) circuits of (11) Modules Utility PV AC Disco lfaucrtt Lacl<al,>le DiscoFttiecE 30A Non -Fused Disconnect -- i at..d ldja- n to PULn \ktu Fc`�f Conduit (in)L1,t2,N (Awg) Ground (Awg) OCPD pAfterCombl2er1 B 0.75 10 8 30 eaker injection ' C 0.75 10 8 30 Note: -All wiring to meet the 2017 NEC and Florida electric codes. 30A Disconnect -Type of conduit to be determined on site by contractor. Install Aill be dole to Manutactul-er S 30A 0 r � M Main Service 150A 200A Bus C GEC Load Side Connection Busbar Rating - 1 20( - - - -- Main Breaker Size ' 15C — _ - Bus Rating * l 2-Main Break Size 90 Max Allowable Load Side 90 Load side connection Per 705.12(B)(2)(3)(b) Use Matching or equivalent approved breaker if derating (ill(' NOl],S t :ra roue Er ci ss steno l ;rr 6901. I1( <<)(1) 6F?C must be installs 1 per 250.6I i:C mu.A be continuous un-spliced of arteverSiE is ,JlheQd Flom inserter to c sestina scrkicc unound �,te:n of continuous fi-olnt the amass to the existim-, .c,r ice 21­011nd sssteni Cie C n�rr,t be ruin 8 A`,k G auui Installed in conduit I( (it C is riot rrt coolluit. it mist be 'O mul Disconnects will be Visible, lockable, adjacent to and within 10, of Utility ITteter All Labels & N4ar}kings for photovoltaic system will be reflective and meet all rec(tlireinents for NF PA I I.12 MARCUS LUGO & LERIANIS VEGA 7870 BROAD POINTE DRIVE ZEPHYRHILLS, FL 33540 NEC LABEL NOTES; '_. THE WARNING SIGN(S) OR CABEL(Sj SHALL COMPLY VNTH NEC 110.21(B} 2. LABELS St-IALL BE SUITABLE FOR THE ENVIRONMEN"( WHERE THEY PRE €NSTALLED. 3. LABELS TO BE A MIN I ETTER HEIGHT OF 3/8" AND PERMANENTLY AFFIXED. 4, LABELS SHALL ALSO COMPLY WITH THE SPECIFIC REQUIREMENTS OF THE AUTHORITY t-IRVING JURISDiCI ION, Godwin- I WII V t 's 11� r I' 526 D. II# E at • • 14451 ♦i Clearwater, FL 33760 844-987-6527 Date: 3/4/2022 Inverter Type: Enphase IQ7-60-2-US Pv Panel: (22) Q.PEAK DUO BLK-G 10+ 360 Total wattage: 7,92ow : Drawn �3 y VK Revised by: VK Rev #: 1 Rev Date: 4/8/2022 Page: E-1 Systern rnects the grounding requirements of NEC 690,43 Fho Placard shall hcpeun uoonuy hmud—. and Shall bcmm&"fled, "emxerpoml.hadplastic- »hh cuLruved"biteblock luadv� +\ placard ill tic added i(h il!,Sh-LICfl0H,S and locations to bell Rapid 8huk��wn Built in |ounm�ian�owN�N|�� | 21'50.58 N6C69O# Per Code N0C 690 12 11V AC disconnect is Conductors have a nnin Everything will be built t10 Code without all Specifics labeled on Plar Smoke Detectors �vfll be added as per FBC 55 1,883 Nlarkings shall be placed on ill[ DC CondiritS, 1)(7 Combiners, Raceways, FAICIOSUreS, Junction Boxes, and Cable Assemblies Lit every 10', turns, and above and below penetrations i n compliance with NFPA Disconnect means shall be provided for all disconnecting all ungrounded conductors that supply or pass through the building or structure Per Code 2O17NEC Section 225,31 B<Section 22S.32 E04. Construction documents specify PVoystemcircuits installed on or in buildings include a rapid shutdown function that controls specific conductors inaccordance with NEC article 690.12. E05 These construction documents specify that mlabel is provided with the method bninitiate rapid shut down per O9O.12(4). E00. Construction drawings specify buildings or structures with both utility service and a PVaystam. complying with NEC article O9O]2shall have apermanent plaque ordirectory including the following mmnding�"PHOTO VOLTAIC SYSTEM EOU|PPED'VVITHRAPID SHUTDOWN" osper NEC article 6B0,5O(C). E07. Construction documents specify PVpower circuit labels shall appear onevery section ofthe wiring system that ia separated by endosumu, wm||s, partitionp, ceilings, or floors. Amp Temp Correction Factor O94 31015(B)(2)(a) All Exterior equipment is A minimurn of Nenna-R3 Rated EOG.Construction documents specify all warning eign(n)or |abeKs) shall comply with NEC article 11O21 (8).Lmbel warnings shall adequately warn of the hazard. Labels shall be permanently affixed 0athe equipment, and Lebn|n required � shall besuitable for the environment. | '....~..`—.~/.~..`°.~.~~..~`...^~~.. with other sources shall be marked at an acces|b|e location atthe disconnecting means asapower source and with the rated acoutput current and the nomina|operating A[voltage. Per NEC 690,54 | Disconnect iSiQcompliance 23)M2 Supply side disconnect adjacent to Msp Over Current Protection Device is "Next size up" Based on Inverter Maximum Continuous Output Current Rating 2017 NEC 240.4(B) -All new equipment I,abels will be placed located adjacent to in the correct location Meter oil exterior xNall Per Code NEC690.56(B), Include required label for metallic raceways and conduits to aheete'1 per NEC article oeo.a1(a)(3). Add required label usheet s-1 per NEC amu*ros.1n, Include required label tosheet E-1 per NEC article ros.112(u) Photovoltaic ACdisconnect shall b*capable ofbeing locked in the open position per NEC omue7on.zz(6). Photovoltaic Acoveounentprotection shall uelocated within 10feet u,the point where conductors ai aconnected m the semicoper NEC 7on�o1 In compliance with 230.71 Combiner box in compliance Per Code N EC78S. 12 2*ZOA<|25A *No othcrloads k`hmadded | Permanent sticker added to disconnect InCase of8murcrencyCall Apply tmMain Disconnect Green HouacSolar &Air | at 844-987-6 3/8 IN MIN. TEXT TURN RAPID SHUTDOWN SWITCH TO 3116 IN MIN. TEXT: THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE 1 louse -Mwkm�,, Shall h� i,d ilh MwQ UtQimIg i�ilh nimmitim �" Capoid I o DUAL POWER SUPPLY SOURCES: UTILITY GRID AND Note- PV SOLAR ELECTRIC SYSTEM -Subject PV Systems has been designed iomeet the reguioneu1yofthe NEC 20l7INVERTER and those set forth by the Florida Solar OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE Energy Center Certification, Including Maximum Number o[Module Strings, Maximum number ofmodules per string, POWER SOURCE OUTPUT CONNECTIONi Maximum Output, Module Manufacturer and DO NOT RELOCATE THIS OVERCURRENT So T DEVICE 000do| uunuhec inverter manufacturer and model nunuber,oy:pp|icable. NFC 705. 10 A permanent placiLle or directory, denoting the location of all electric power source disconnecting means on or in the premises. shall be installed at each service equipment location and at the location(s) of the system disconnect(s) for all electric power production sources capable of being interconnected. One sign required for each PV system. Inc|adino tile Libel b6o� NOR MA8CUS L0GO& LER!&NIS VBGA 7870BROAD P{}IN-[BDRIVE ZE9HYRHlLLS,FL 33540 Figure 69050(C](l)(a)Label for PVSystems that Shut down the array and the conductors leaving the array Godwin Engineering and RX Design, LLC Pensacola, FL 32526 Green House Solar & A Clearwater, FL 33760 Inverter Type: �����0-2-nS pvr^ur|: O.PEA&DUO BLu-G\0+360 {nsta}|v/Ul6edone toMail ufact ozS Iron Ridge XR-10 Rail 13 54 Iron Ridge UFO's 20 Iron Ridge Sleeves/End Caps I Roof Top Combiner 5 Iron Ridge Ground Lugs 22 QYEAK DUO BLIP-GIO+ 360 22 Enphase IQ7-60-2-US I 30A Non -Fused Disconnect I 30A Breaker 2 20A 2P Breaker I Enphase Combiner Box Max cantilever is 16" as per manufacturer Spec. Zone 1: Max Cantilever = Max Span * (13)=4811*(31)=16 Max cantilever is 16" as per manufacturer Spec Inverter Type: Zone 2e: Max Cantilever = Max Span * (1)=48"*(1 3 3)= 16 PV Panel: Max cantilever is Zone 2r: 16" as per manufacturer Spec. Racking: Total Wattage: Max Cantilever = Max Span 48It* 3)=' ob=I6Roof Type: Max cantilever is 16" as per manufacturer Spec. Wind Load: Zone 3: Max Cantilever = Max Span * (1)=48"*(31)=16 3 Fastener Type: FrjFVA[_*j R-1 # Modules (22) Pitch: 20' Azimuth: 180' Enphase IQ7-60-2-US (22) Q.PEAK DUO BLK-G10+360 Iron Ridge XR- 10 7,92OW Composition Shingle 7 to 20 Deg Use 5/16" Dia 4" Lags MARCUS LUGO & LERIANIS VEGA 7870 BROAD POINTE DRIVE ZEPHYRHILLS, FL 33540 Proposed Mounting locations n Plans satisfy zones I- 13C - 15 10.7.1 Install will be clone to MaIlLIfiaCtLIFel- GO Godwin Engineering and Design, LLC Z 60 % 8378 Foxtail Loop Pensacola, FL 32526 E OF 4U D. Chad Godwin, PE Chad (& /godwineng.com �r��� f A L Green House Solar & Air 14451 60th Street N, Clearwater, FL 33760 844-987-6527 Date: 3/4/2022 Drawn Revised by: VK �R ly-.TMly'rill 111 Page: S-IA BREAKING THE 20 % EFFICIENCY BARRIER Q.AN TUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9 %. THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY Q CELLS Is the first solar 'nodule manufacturer to pass the most comprehen- sive quality programme in the industry: The new `Quality Controlled PV' of the independent certification institute TUN Rheinland. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent love -fight and temperature behaviour. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology, Anti AID Technology', Hot -Spot Protect and Traceable Quality Tra.Q'"'. EXTREME WEATHER RASING High-tech aluminium alloy frame, certified for high snow (5400 Pa) and wind loads (4000 Pa). C� A RELIABLE 1tNVESTTAIENT a ��f Inclusive 25 year product warranty and 25-year linear performance warranty'. t T tesr and-tr o i ng . s IECL 7804 _2015, rue h .J E (-1500 / 96Y .n, dd a S on' nru I- 'or f,.rthEf fo don_ THE IDEAL SOLUTION FOR: Ro 1 G ,'Sys v^ �e a I rl build ngs Engineered in Germany MECHANICAL SPECIFICATION mm 32mm tincludmg frame) in- ef,i�rrrt 199Ina -{ .... tee., nm .... ._. 'i _ oor C;uver 3.2mrr thermally pre -stressed glass with ____--- . _ 7 anti-rerlAtiun technology .ark "orar Composite th,- - rf•r Black anod scn aajm niur^ " 6 r 20 ^ronocrystall no Q A\ f )M solar rn1`- cells � r ,r Itch nor. 23-101mm >; 32-60mm x 15-18 mm I Stec i n class IP67 mtr, oycas o ones 4mm- SoIf r canle. rl>1150m T, (,-II GIri r a�n .-s ova „nc -crr- _rlaaabl MC 4 IP68 v ELECTRICAL CHARACTERISTICS POWER CLASS 350 355 ...� 360. 365 370 . A I P1 i Idi1M P Ef..).. MA 7CEA SiAN DA,Y., is5 Qal!,,T lG rl o 3 f ry (}/s,aPIQ;-_RA1GE+a ' 0'of a• 1r..._,......._.._,._.._____[fJ] 350 m...� 355 360-�- ----365 370 IP [A] 10.97 11.00 1124 11.07 11,10 Cr­.. _ul. roIt. s .r V - IV] 41.71 41.14 41,18 41.21 41,24 Curop l a=..rS§' I-, [A] 10.37 10.43 1049 10.56 19,62 valm 7, .. P;;T V « [V] 33,76 34.03 34,31 34.58 34.84 ,..., ..._-_.... __..._.._._.._ ._....._....-_- ....._-_____--_.._..�__ ._.._..__........_._.__.-_--------- . _ ._____.. _---- .-...__,._............._ F,flcp (%j >_19.5 19.8 a20.1 >>-20.3 >_20.6 1IINIk,MI _P:0oF-:, 1.,.� A r N.0RrA, C,L I: Po I M.o.,.OND O o.h"AO Po,iInP p. ,; [W] 262.6 2.66.3 970.1 273.8 277.6 Situ'!Cfr .i.0 current I_- [At 8,84 8,87 889 892 8.95 span Vot.,d, V.; [V' 3877 38.80 38.83 38.86 33.90 '"urnf ti 0. ^k PP I,,o [A] 3,14 8,20 8,26 8,31 8,37 itsAtrg.a c r0pis Vo IV] 32.24 32,48 32.71 32.94 33.17 M-surement tolerances P. ° 3 % 1<.,, V 5 o at STC. 1000 VAm 25 r"C, AM 1 5 according to lfiiC 60904 3 •'800 W/ n2, NMOT Spectrum Aid t 6 Q CELLS: PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE Atleast 98 of ominal uo Aer um - ,a first Isar Ihe,eafte. max. J.54r, --- degradation per year At least 93.5o of nominal ponrer up t 10 yea 5_AL least86 s oI nArrmai p a. r..p to 2F yeas. All data wiThjn me assure..- e oler ances. Full warranties inaccordanoe Mn the warranty terms of the zoo a -coo non loco Q CELLS s tes-ganisation of your :o respective country. _ rypica) module pArforr-la _ ce under low rf Iradian- oton s in +, comps - I oArCc> c,, ors(25 !OjOvi/m'). TEMPERATURE COEFFICIENTS - l inp -at., coshca-rofi_._ _ _ . a Is/,] _. .__ J.04 ... i.fn;e,a attar. Co_ffi„.,nt sJ.._ �. '.. poi K; _.._-._027. vm: y [/o K] ..34 N., tina,,..1ofa. a<ircT, avert,,- NM') T 43_, PROPERTIES FOR SYSTEM DESIGN Ahrirr,nm S/=e-+r.?c!2aga r/,.. tVl 1001) P, module r9a Ica=lor. Class11 vi, , „um ? .. .: Cs. rent 1TA, 20 Fir cif rg ^ .. nr. Aado., t, , r %3t. C/TYPE 2 slar l st'-, Purr, �r1.JI [Pal 3600/2660 f,.,w!Uaa fa hirelens,_ %',, 40'C-+85°C _- .nrtinu^uwatd [Pa) 5400/4000 QUAT..IFi CATTONS AND CERTIFICATES 1 - II tl 6 If! r r nl I t I J J :�,ficl. ori mgo ng io nrrzxorzn Note. Ins,,Aat or mS rucl n„ m i,o r c IFe iIstallat or and r,e'atinq manual or cor act our teci-rlcul.,an c depsr•ment (or ; tser Inlormar'orr on appro d installation and .,ssof this product. Hanwha 0 CELLS GmbH 7 21, 06766 P, tterfaid-wnl e C,ermany I TEL -49 (03494 6699-23n.4a i PAX 9 ou3494 6699,.30001 EMAIL saleCa ,,.,Ildoo, I INE8 www_q cells..,om_ Engineered in Germany 0CElLS ­e t Enphase Microinverteis 1 -7 Q' and Ir", _7 - U Microinverters �CERFIL=FED The high-powered smart grid -ready Enphase IQ 7 MIcro" and Enphase IQ 7+ Micro'" dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy'"", Enphase IQ Battery", and the Enphase Enlighten- monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, enabling Enphase to provide an industry -leading warranty of up to 25 years. Lightweight and simple Faster installation with improved, lighter two -wire cabling Built-in rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable Optimized for high powered 60-cell/120 half -cell and 72- cell/144 half -cell* modules More than a million hours of testing Class 11 double -insulated enclosure UL listed Smart Grid Ready Complies with advanced grid support, voltage and frequency ride -through requirements Remotely ripostes to respond to changing grid requirements Configurable for varying grid profiles Meets CA Rule 21 qJL 1741 -SA) ,The IQ 7+ Micro is required to support 72-cel 1/ 144 half -cell modules Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA (DC) IQ7-60-2-US IQ7PLUS-72-2-US Commonly used module pairings' 235 W - 350 W + 235W-440W+ Module compatibility 60 cell/120 half -cell PV modules 60-cell/120 half cell and 72- only cell/144 half-clall PV modules Maximum input DC voltage 48 V 60V Peak power tracking voltage 27 V - 37 V 27V-45V Operating range 16V-48V 16V - 60 V Min/Max start voltage 22 V /48 V 22 V / 60 V Max DC short circuit current (module Isc) 15A 15A Overvoltage class DO port 11 11 DC port backfeed current 0 A 0 A PV array configuration I x 1 ungrounded array; No additional DC side protection required, AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) IQ 7 Micrainverter IQ 7+ Microinverter Peak output power mm 250 VA 295 'VA. Maximum continuous output power 240 VA 290 VA Nominal (L-L) voltage/range' 240VI 208V/ 240 V / 208 V/ 211-264 V 183-229 V 211-264 V 183-229 V Maximum continuous output current 1.0 A (240 V) 1.15 A (208 V) 1.21 A (240 V) 1 39 A (208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47 - 68 Hz 47 - 68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A (I_-L) branch circuit' 16 (240 VAC) 13 (208 VAC) 13 (240 VAC) 11 (208 VAC) Oveirvoftage class AC port fit fit AC port backfeed current 18 mA 18 mA Power factor setting 10 1.0 Power factor (adjustable) 0.85 leading 0.85 lagging 0.85 leading 0.85 lagging EFFICIENCY @240 V @208 V @240 V @208 V CEC weighted efficiency 97.0 A 97.0% 97.0% 97,00 MECHANICAL DATA Relative humidity range 4% to 100% (condensing) Connector type MC4 (or Amphenot H4 UTX with additional Q- DCC-5 adapter) Dimensions (HxWxD) 212 mm x 175 1 x 30.2 mrn (without bracket) Weight 1,08 kg (2.38 Ibs) Cooling Natural convection - No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class 11 double -insulated, corrosion resistant polymeric enclosure Environmental category UV exposure rating NEMA Type 6 / outdoor FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaivated and approved by UL for use as the load -break disconnect required by NEC 690- Compliance CA Rule 21 (UL 1741 SA) LIL 62109-1, Ul1741/1EEE1547, FCC Part 15 Class B, ICES-0003 Class B, 'AN/CSA-C22,2 NO. 1071-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DO conductors, when installed accordina manufacturer's instructions. I No enforced DC/AC ratio. See the compatibility calculator at htrpa,ZLanphase _a - ni/r _.?n 2 No -ninal voltage range can be extended beyond norrinial if required by the utility 3 Limits may vary ;defer to local requirements to define the number of rniccurivertei a per branch in your area To learn more about Enphase offerings, visit enphase.corn ENPHASE To learn more about Enphase offerings, visit enphase.com -"�ENPHASE ,-Fir ,',11 nyh ir n.,h 0 l, 2 r Eophase Networking Enphase Q ( orribiner 3-ES.'3r-1._ S X-1Q-AM1-240-3-ES X-1Q-AM1-240-3C-ES To learn more about Enphase offerings, visit enpha� se co m The Enphase IQ Corobigner 3-ES/3C-ES '' with, Enphase IQ Envoy" and integrated LFE-M I cell moderi-i (Included only with IQ Cornbinef K- F-S) consolidates interconnection equiprlent Into a single enclosure arid streamlines PV and storage installations by providing a consistent, pre -wired solution for residential applications. It offers UP to four 2 pole input chcuits and Eaton BR series busbar assembly. Includes IQ Envoy for communication and control Includes LTE-M1 cell modem (included only with IQ Combiner 3C-ES) Includes solar shield to match Ensemble esthetics and deflect heat Flexible networking supports Wi-Fi, Ethernet, or cellular Optional AC receptacle available for PLC bridge Provides production metering and consumption monitoring Reduced size from. IQ Combines (X-IQ-AIVH-240-2) Centered mounting brackets support single stud mounting Supports back and side condo entry Up to four 2-pole branch circuits for 240 VAC plug-in breakers (not included) 80 A total PV or storage branch circuits Durable KIRTL-certified NEMA type SIR enclosure Five-year limited warranty wo years labo, reimbursement program, coverage included for both the Combiner SKU's Ul. listed "nENPHASE IV_A Enphase IQ Combiner ®E / 3C-ES MODEL NUMBER IQ Combiner 3C-ES (X-IQ-AM1 -240-3C-ES) IQ Combiner 3C_ ES with Enphase IQ Envoy printed circuit board for integrated revenue grade Pr/ production metering (ANSI C12.20 +/- 0.5%) and consumption monitoring (+/- 2.5%). Includes Enphase Mobile Connect LTE-Ml (CELLMODEM-MI), a plug -and -play industrialgrade cell modem for systems up to 60 rn croinvertefs. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area.) Includes a silver solar shield to match the Encharge storage system and Enpower smart switch and to deflect heat. ACCESSORIES and REPLACEMENT PARTS (not included, order separately) ....... .... Ensemble Communications Kit Includes COMMS-KIT-01 and CELLMODEM-Ml with 5-year data plan for Ensemble sites (COMMS-CELLMODEM-MI) Circuit Breakers Supports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers. BRK-110A-2-240 Circuit breaker, 2 pole, I OA, Eaton BR210 BRK-15A-2-240 Circuit breaker, 2 pole, I 5A, Eaton BR21 5 BRK-20A-2P-240 Circuit breaker, 2 pole, 20A, Eaton BR220 EPLC-01 Power line carrier (communication bridge pair), quantity - one pair XA-SOLARSHIELD-ES Replacement solar shield for Combiner 3-ES / 3C-ES XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3-ES / 3C-ES (required for EPIC-0111) XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board (PCB) for Combiner 3-ES / 3C-ES ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 120/240 VAC, 60 Hz Eaton BR series busbar rating 125 A Max. continuous current rating 65 A Max. continuous current rating (input from PV/sloragie) 64A Max. fuse/circuit rating (output) 90 A Branch circuits (solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation (IDG' ) breakers only (not included) Max. total branch circuit breaker rating (input) 80A of distributed generation / 95A with IQ Envoy breaker included Production metering CT 200 A solid core pre -installed and wired to IQ Envoy Consumption monitoring CT (CT 200-SPLiT) A pair of 200 A split core current transformers PAECHANICAL DATA m IS cm) w,­rt-h--mounting- brackets. Weight 15 kg (16.5 lbs) Ambient temperature range -40- C to +46- C (-40- to 115Fj - ',acting Natural convection, plus heat shield Wire Sizes 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors 60 A breaker branch input 4 to 1/0 AWG copper conductors Main lug combined output 10 to 2/0 AWG copper conductors Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. Altitude To 2000 meters (6,560 feet) INTERNET CONNECTION op riONS integrated Vih-Fi 802,11b/g/n Cellular CIELLMODEM-M1-0i5 4G based LTE-MI cellular modem included only with IQ Combiner 3C-ES), Note that an Enphase Mobile Connect cellular modem is required for all Ensemble installations. Ethernet Optional, 802-3, Cat5E (or Cat 6) UTP Ethernet cable (not included) COMPLIANCE Compliance, IQ Envoy UL 60601 -1 /CANCSA 22.2 No, 61010-1 To learn more about Enphase offerings, visit enpha5ig com ,ire �)r a n ENPHASE e "O.APA'066 IRONRIDGE XR Rail Family XR Rail Family N, a rs; T I o t A I w a y s I•N IN I but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. XR Rails are the structural backbone preventing these results. They resist uplift, protect against buckling and safely and efficiently A '211 transfer loads into the building structure. Their superior spanning capability requires fewer roof attachments, reducing the number of roof penetrations and the amount of installation time. Sloped roofs generate both vertical and lateral forces on mounting rails which can cause them to bend and twist. The curved shape of XR Rails is specially designed to increase strength in both directions while resisting the twisting. This unique feature ensures greater security during extreme weather and a longer system lifetime. Compatible with Flat & Pitched Roofs R Rails are NOWN E, f IronRidge offers I tilt leg compatible with lashFootand fl/y/` a range of 11, "wo- aw. - options for flat other pitched roof W v '01 A roof mounting I Va attachments. 301r applications. All XR Rails are made of 6000-series aluminum alloy, then protected with an anodized finish. Anodizing prevents surface and structural corrosion, while also providing a more attractive appearance. XR10 XR10 is a sleek, low -profile mounting rail, designed for regions with light or no snow. It achieves spans up to 6 feet, while remaining light and economical. 6'spanning capability Moderate load capability Clear & black anodized finish Internal splices available XR100 is the ultimate residential mounting rail. It supports a range of wind and snow conditions, while also maximizing spans up to 10 feet. 10'spanning capability Heavy load capability Clear & black anodized finish Internal splices available I'll "WOU 1111 NOW I 10111"W" Pon as, WM - ### 0- 0, "M -WAmmuk0i X R 1000 is a heavyweight among solar mounting rails. It's built to handle extreme climates and spans up to 12 feet for commercial applications. 12'spanning capability Extreme load capability Clear anodized finish Internal splices available 'Table is meant to be simplified span chart for conveying general rad capabilities. Use approved cerlificpfion letters for actual design guidance. % F R 0 N T Inverter Type: Enphase IQ7-60-2-US PV Panel: (22) DNA-120-MF26-360W Racking: Iron Ridge XR- 10 Total Wattage: 7,920W Roof Type: Composition Shingle 0 Wind Load: 7 to 20 Deg Fastener Type: Use 5/16" Dia 4" Lags F Sheet Index S-1 Cover Sheet / Site Plan S-2 Detail E-I One - Line E-2 Electrical Code S-IA Mounting Plan General Notes: 0 -Enphase IQ7-60-2-US Micro Inverters are located on roof behind each module. U -First responder access maintained and from adjacent roof. S -Wire run from array to connection is 40 feet. 14451 60th Street N, Clearwater, FL 33760 844-987-6527 V- 6 Llegend First responder access (;rOUnd Access Chimney Utility Meter Satellite Vent Pipe PV Disconnect 9 Utility Meter -COGE'N Disconnect Located adjacent to Utility meter System meets the requirements of NFPA 70th F.dition, Chapter 1 i , i Meets All Editions of Florida Fire Prevention Code 2020 7th Edition Meets all requirements of NFPA- I 7th Edition and NFPA- 10 1 -Z Represents all Fire Clearance Ist Responder Access including Alternative methods minimum of 36" unobstructed as per Section R324 of the 2'/,-,,() IRC Meets the requirements of the following- (2020 FL Residential Code & FBC, 7th Edition (2020 International Residential Code) - 2nd Printing modified by the FL Building Standards, 2020 Florida Building Energy Conservation Code 7th edition, City of Zephyrhills Code, 2017 National Electric Code.) # Modules (22) Pitch: 20' Azimuith: 180' Install t.% ill be done to MalltttIlCtUrer Spec Layout Subject to Change Based on Site Conditions Godwin Engineering and Design, LLC 8378 Foxtail Loop Pensacola, FL 32526 D. Chad Godwin, PE Chad@godwineng.com MARCUS LUGO & LERIANIS VEGA Date: 7870 BROAD POINTE DRIVE Drawn by: VK Revised by: ZEPHYRHILLS, FL 33540 Rev Date: Compass for Aerial Ironridge XR- 10 General Notes: - Flashlocs are secured to roof rafters. 48" O.C. in Zone 1, g 48" O.0 in Zone 2e, 48" O.C. in Zone 2r & g 48" O.0 in Zone 3 using 5/16" x 4" stainless steel Lag bolts. - Subject roof has One layer. - All penetrations are sealed and flashed. R1 4/12 2 x4" @ 24 O.C. -Roof Height 15' -Per 2020 FBC, the Roof Mounted PV System will be subject to the following design criteria-. Design Wind Speed(Vult) - 140mph 3 see gust, Exposure Category - C -Designed as per ASCE7-16 12 Truss Inverter Type: PV Panel: Racking: Total Wattage: Roof Type: Wind Load: Fastener Type: Enphase IQ7-60-2-US (22) DNA-120-MF26-36OW Iron Ridge XR- 10 7,92OW Composition Shingle 7 to 20 Deg Use 5/16" Dia 4" Lags I Solar ,310-16 X 3/4, *4EX HEAO SOLT 3/8-16 Ft^NGE NU T MARCUS LUGO & LERIANIS VEGA 7870 BROAD POINTE DRIVE ZEPHYRHILLS, FL 33540 um Install will be done to Manufacturer Spec Design, LLC 8378 Foxtail Loop Pensacola, FL 32526 D. Chad Godwin, PE Chadagodwineng.col Date: 3/4/2022 Drawn by: VK Rev Date:- Irl Green House Solar & Air 14451 60th Street N, Clearwater, FL 33760 844-987-6527 12-2 Romex can be used for interior building outdoorromex in conduit or environments. I 410 AWG THWN for Home runs (I) Line I (I) Line 2 Per Circuit 98 AWG THWN (1) EGC Inside @ least 3/4" Conduit (tbd on site) Enphase Output Ckt Per String ( r To Overcurrent Protection Device AC Max Output Current 11 AC Max Output Current * 1.25% 1.8 Overcurrent Protection �� 0 C No. of Current Carryin&Cond <4 Conductor Gauge (AWG) 10 Enphase Total Output Ckt AC Max Output Current AC Max Output Current * 125% 1 27.5 _ Overcurrent Protection (A) �L30 No. of Current Carrying Cond <4 Conductor Gauge (AWG) -_. - - 1t - 117C3udiltg the label below EmergencyIn Case of Green House Solar & Air Meets 1 1.12.2,1.5 Enphase IQ Trunk Cable Q-12-240 #12AWG THHN-THWN-2 UL 9703 -L- - IGrounding Conductor to be bare #8 Awg NEMA 3R Junction Box Black- LI Red - L2 Green - Ground RATED AC OUTPUT CURRENT: 22A NOMINAL OPERATING VOLTAGE: 240VAC Enphase Combiner Box (1) - 20A Breaker Per Circuit 2 Circuits 240V 10/15A Breaker for Envoy Disconnect Solar Combiner Box �X-IQ-AM I -240 s i ! Inverters: (22) Enphase IQ7-60-2-US Micro Inverters Circuits: (2) circuits of (11) Modules Utility PV AC Disco Manual Lockabi Di comwct. 30A Non -Fused Disconnect L x.lcd ,adi," t ac ('.i6p '4ch•r , After CombirN � I--- �Mmw f +: Note: -All wiring to meet the 2017 NEC and Florida electric codes. 30A Disconnect -Type of conduit to be determined on site by contractor. Install will be doge to MailLil'aCtUrer S Main Service 150A 1 200A Bus 30A GEC Load Side Connection Busbar Rating 200 Main Breaker Size I50 Bus Rating * 1.2-Main Break Size T - 90 Max Allowable Load Side 90 J Load Side Breaker Size 30_-_______; Load side connection Per 705.12(B)(2)(3)(b) Use Matching or equivalent approved breaker if Berating (,EC; NO Fi;S [ �n nulnd i s%stern per 690 41(A)(F) 6EC niust be installcd per 25061 CLC must ire continuous un-,phced yr Lllevcrsibk spliced thin im enter to xt,tink_' sel � ice ri o Incl 5, stcna or continuous from the arra} s to tit, existing scivice giound ;:,tens. .iil,C must be vain 4-8 AWG and installed in conduit If 61:C is not in onkillit- it najl t b=_' -6 111111 Disconnects will be Visible. lockable. adjacent to and ,vithin 10' of utility meter All Labels & Markings for photovoltaic system will be reflective and rneet all regUirernents for NFPA 1 1.12 Customer Info: MARCUS LUGO 8L LERIANIS VEGA 7870 BROAD POINTE DRIVE ZEPHYRHILLS, FL 33540 NEC LABEL NOTES: 1. THE WARNING SIGN(S) OR LABEL(S) SHALL COMPLY WTH NEC 110.21(B) 2. LABELS SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE THEY ARE INSTALLED. 3. LABELS TO BE A MIN LETTER HEIGHT OF 3/8" AND PERMANENTLY AFFIXED. 4. LABELS SHALL ALSO COMPLY WITH THE SPECIFIC REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. Godwin Engineering and�� C - (;0 Design, LLC as 8378 Foxtail Loop 0 2 3� ; Pensacola, FL 32526 ,F 0 �� OF D. Chad Godwin, PE >` Chad@godwineng.com 11ill '�i®.��� HouseGreen Solar#w Air 14451 *0 Clearwater, FL •' 844-987-6527 Date: 3/4/2022 Inverter Type: Enphase IQ7-60-24US Pv Panel: (22) 1 DNA-I20-MF26-360W Total Wattage: 7,920W Drawn y: VK Revised by: Rev #: 00 Rev Date: Page: E-1 System meets the grounding requirements of NEC 690.43 The Placard shall be pernianenth, �: -A placard will be added with riveted_.. and shall be made ofre&: instructions and locations to be weatherproof, hard plastic, with in compliance N� ith 690.12, engraved white block Icttering. 690.56(B) and NEC 705.10 Rapid Shutdown Built in In compliance with NEC;:� 250.58, NF(_'690X Per Code NEC 690.12 1 : NI 250,24, NI?('25024(1)) 13V AC disconnect is Conductors have a min lockable in the open position' arnpacity of 60 amperes per code NEC 705,22(7) :: Per Code NEC 230.79(D) Everything will be built to Code without all Specifics labeled on plan System is in cornplaince with FFPC 1: 11 . 12 7th Edition. To Overcurrent Protection Device iiF a F _95 Eug_ ii zim_ c 75T 9 <4 rent 22A � * L25% 28A Smoke Detectors Neill be added as per FBC 553.883 All Exterior equipment is A minimum of Nema-R3 Rated Markings shall be placed on all DC Conduits, DC Combiners. All Interactive System(S) Points of interconnection with other sources shall be marked at an accesible Raceways, Enclosures, Junction Boxes, and Cable Assemblies location at the disconnecting means as a power at every 10', turns, and above and below penetrations in source and with the rated ac output current and the compliance with NFPA nominal operating AC voltage. Per NEC 690.54 Disconnect means shall be provided for all disconnecting all ungrounded conductors that supply or pass through the building or structure Per Code 2017 NEC Section 22S,31 & Section 22S.32 E04. Construction documents specify PV system circuits installed on or in buildings include a rapid shutdown function that controls specific -conductors in accordance with NEC article 690.12. E05. These construction documents specify that a label is provided with the method to initiate rapid shut down per 690.12(4). E06. Construction drawings specify buildings or structures with both utility service and a PV system, complying With NEC article 690.12 shall have a permanent plaque or directory including the following wording: ' PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN" as per NEC article 690.56 (C). E07. Construction documents specify PV power circuit labels shall appear on every section of the wiring system that is separated by enclosures, walls, partitions, ceilings, or floors. E08. Construction documents specify all warning sign(s) or label(s) shall comply with NEC article 110.21 (B). Label warnings shall adequately warn of the hazard. Labels shall be permanently affixed to the equipment, and Labels required shall be suitable for the environment. Disconnect is in compliance 230,72 Supply side disconnect adjacent to Msp Over Current Protection Device is "Next size up" Based on Inverter Maximum Continuous Output Current Rating 2017 NEC 240.4(B) All new equipment 1,abels will be placed located adjacent to in the correct location Meter on exterior wall Per Code NEC 690.56(13), 690.56(('), & 690.53 Include required label for metallic raceways and conduits to sheet E-1 per NEC article 690.31 (G)(3), Add required label to sheet E-1 per NEC article 705.10. Include required label to sheet E-1 per NEC article 705.12(8) Photovoltaic AC disconnect shall be capable of being locked in the open position per NEC article 705.22(6). Photovoltaic AC Overcurrent protection shall be located within 10 feet of the point where conductors are connected to the service per NEC 705.31. In compliance with 230.71 Combiner box in compliance Per Code NEC 705.12 2* 20A < 125A *No other loads to be added Permanent sticker added to disconnect In Case of Emergency Call Apply to Main Disconnect Green I IOUSe Solar & Air at 844-987-6527 3/8 IN MIN. TEXT TURN RAPID SHUTDOWN SWITCH TO 3/16 IN MIN. TEXT� THE "OFF" POSITION TO I SHUT DOWN PV I SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. Bteaker lt�jcction will bc done in Meter s4ain Cornbo Located Outside I louse -Mw�m,,,s shal, Be ; dkcfiv�, weall"I R�sistanl and uilabl, tm th, shali l" I'd �ifll k�hit� "ah mimmum Capoal Let S DUAL POWER SUPPLY SOURCES: UTILITY GRID AND Note. Pv SOLAR ELECTRIC SYSTEM -Subject PV Systems has been designed to meet the requirments of the NEC 2017, and those set forth by the Florida INVERTER OUTPUT CONNECTION: DO NOT RELOCA TE THIS •Solar OVERCURRENT DEVICE Energy Center Certification, Including --------------- J Maximum Number of Module Strings, Maximum number of modules per string, POWER SOURCE OUTPUT CONNECTIOt,�. Maximum Output, Module Manufacturer and DO NOT RELOCATE THIS OVERCURRENT DE model number, inverter manufacturer and model number, as applicable. NEC 705. 10 A permanent plaque or directory, denoting the location of' all electric power source disconnecting means on or in the premises. shall be installed at each service equipment location and at the location(s) of the system disconnectils) for all electric power production sources capable A� of being interconnected . One sign required for each PV system. Plans Satisfy NEC 250,94 & NEC250.53(A)(2) Including the label below MARCUS LUGO & LERIANIS VEGA 7870 BROAD POINTE DRIVE ZEPHYRHILLS, FL 33540 Figure 690.56(C)(1)(a) Label for PV Systems that Shut down the array and the conductors leaving the array Godwin Engineering and C. E Ala Design, LLC * , 0 360 8378 Foxtail Loop I Pensacola, FL 32526 =:-a % TATE OF D. Chad Godwin, PE Chadgodwineng.com e.A' OR 10,(& 3/4/2022 VK Green House Solar & A 14451 60th Street N, Clearwater, FL 33760 844-987-6527 1 Inverter Type: Enphase IQ7-60-2-US PV Panel: (22) DNA-120-MF26-360W Total Wattage: 7,92OW Install \%ill be done to MauLIf,1CtUrCr S 1-0-M IKI MEN= 41 01111011 4 oSplice Bar 48 Unirac Flashloc 54 Iron Ridge UFO's 20 Iron Ridge Sleeves/End Caps I Roof Top Combiner 5 Iron Ridge Ground Lugs 22 DNA-120-MF26-36OW 22 Enphase IQ7-60-2-US I 30A Non -Fused Disconnect I 30A Breaker 2 20A 2P Breaker I Enphase Combiner Box Zone 1: Max cantilever is 16" as per manufacturer spec. Max Cantilever = Max Span * (31)=48 (13)= 1611 Zone 2e: Max cantilever is 16" as per manufacturer spec. Max Cantilever = Max Span * (11)=4811*(11)=I6t1 Zone 2r: Max cantilever is 16" as per manufacturer spec. Max Cantilever = Max Span * 3 (31)=48"*(1)=l611 Zone 3: Max cantilever is 16" as per manufacturer spec. Max Cantilever = Max Span * (31)=48"*(11)=l6?1 3 Inverter Type: PV Panel: Rackinv,: Total Wattage: Roof Type: Wind Load: Fastener Type: (V ­o Proposed Mounting locations R-1 Modules (22 Pitch: 20' Azimuth: 1801' Enphase IQ7-60-2-US (22) DNA-120-MF26-36OW Iron Ridge XR- 10 7,920W Composition Shingle 7 to 20 Deg Use 5/16" Dia 4" Lags MARCUS LUGO & LERIANIS VEGA 7870 BROAD POINTE DRIVE ZEPHYRHILLS, FL 33540 n Plans satisfy zones 143C-1510.7.1 Install will be done to ManUfacturer Spec C Go/// Godwin Engineering and E JVS�i �, Design, LLC 8378 Foxtail Loop Pensacola, FL 32526 OF D. Chad Godwin, PE to # Chadggodwineng.com NAL Green House Solar & Air 14451 60th Street N 60, Clearwater, FL 337 844-987-6527 Date: 3/4/2022 Drawn by: VK Mjwfffr� am Resicentiall or-rimercia 30 Year 3X IEC I RETC Top Warranty Standards Performer -. f 3140 De La Cruz Blvd.. Ste 200 Santa Clara, CA 95054 atoS"-vjwvjaptossolar.com solar rPwMnoicgy info@aptossolar.com Designed & Engineered in Silicon Valley 370W 1 365W 1 36 Our DNA'' Split Cell Series imps essively combines advanced solar technologies to maximize performance. Our patented Dual Nano Ab orber (DNA"') lechr olo gy allovis r.he panel to operate ,it high effflcencies in ex"rerne temherattes. CO n taC i o U I Sc?les te,�fn iroda/ to lE rn If to 1 e 1'l0uT 0 UI" Iltie Of high -efficiency solar panels. Patented DNATI technology boosts power performance & module efficiency Advanced split cell technology with 9 ultra -thin busbars allows for less resistance and more photon capture Ideal solution for applications affected by shading All -black design for pristine aesthetics No excessive silver bussing or ribbons ,c Robust product design is reslient in extreme weather. Up to 5400 Pa snow load and 210 mph 094 wind speeds 98% 97% 90.7% 83.7 0 80.2 % 76.7 0 Linear Performance Warranty 87.8'/0 85 82 F, 1 1 year 10 years 20 years 25 years 30 years 0 Aptos Warranty ® industry Standard 35mm 1039mm Temperature Coefficients P le,npe°ature Coefficients k Temperature Coefficients V -0.36% 0.05 / /`C oar% Number of Modules per Pallet 31) `Dumber of Pallets Der 41.t, Container 26 Pallet n rnenvon; 740 X 1 14D X 11165 Pallet Weight (<g) 640 Container weight (kg) 16640 Aptos Solar Technology reserves the right to make specification changes without notice n-A 12:1 'x 12.1 i S$. 4 [_)aTa Sheet Enphase Microinverters Enphase IQ 7 and IQ 7+ Microinverters (D CER11F[ED The high-powered smart grid -ready Enphase IQ 7 Micro'" and Enphase IQ 7+ tificro" dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy"', Enphase IQ Battery", and the Enphase Enlighten'" monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, enabling Enphase to provide an industry -leading warranty of up to 25 years. Lightweight and simple Faster installation with improved, lighter two -wire cabling Built-in rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable Optimized for high powered 60-cell/120 half -cell and 72- cell/144 half -cell* modules More than a million hours of testing Class 11 double -insulated enclosure UL listed Sm art Grid Ready Complies with advanced grid support, voltage and frequency ride -through requirements Remotely updates to respond to changing grid requirements Configurable for varying grid profiles Meets CA Rule 21 (UL 1741-SA) I The IQ 7+ Micro is required to support 72 cel 1/ 144 half cell modules Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA (DC) IQ7-60-2-US IQ71PLUS-72-2-US Commonly used module pairings' 235W-350W+, 235W-440W+ Module compatibility 60-cell/I 20 half -cell PV modules 60-cell/120 half -cell and 72- only cell/144 half -cell PV modules Maximum input DO voltage 48, V 60V Peak power tracking voltage 27 V - 37 V 27 V - 45 V Operating range 16V-48V 16V-60V Min/Max start voltage 22 V / 48 V 22 V / 60 V Overvoltage class DO port PV array configuration 1 x 1 ungrounded array, No additional DO side protection required, AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) IQ 7 Microinverter IQ 7+ Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nomi I (L-L) volt, 24OVI 209V/ 240 V 1 208V/ 211-264 V 183-229 V 211-264 V 183-229 V Maximum continuous output current 1.0 A (240 V) 1.15 A (208 V) 1.21 A (240 V) 1.39 A (208 V) Nominal frequency 60 Hz 6OHi Extended frequency range 47 - 68 Hz 47 - 68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5A ' �Arms Maximum units per 20 A (L-L) branch circuit' 16 (240 VAC) 13 (208 VAC) 13 (240 VAC) 11 (208 VAC) Overvoltage class AC, port fit, AC port backfeed current 18 mA 18 mA Powei factor setting 1.0 1.0 Power factor (adjustable) 0.85 leading... 0.85 lagging 0.85 leading ... 0.85 lagging FFFICIFNCY @240 V @208 V @240 V @208 V Peak effirciency' 97 5,%, 97-3 % CEC weighted efficiency 9T0 % 97.0 MECHANICAL DATA Ar;�bfnj _temperature Fang`;_ -400C to +650C Relative humidity range 4% to 100% (condensing) Connector type Mt4 (or Arrollenot H4 UTX'with additional Q-DCC-5 adapter) Dimensions (HxWx[l) 212 mm x 175 mm x 30.2 mm (without bracket) Weight Cooling Natural convection - No fans Approved forwet locations yes Pollution degree PD3 Enclosure Class 11 double -insulated, corrosion resistant polymeric enclosure Environmental category UV exposure rating NEMA Type 6 / outdoor FEATURES —Pow—er L—ine—C—omm—u—nication Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DO connectors have been evaluated and approved by UL for use as the load break disconnect required by NEC 696, Compliance CA Rule 21 (UL 1741-SA) UL62109-1, UL1741/lEEE1547, FCC Part 15 Class 8, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2011 5 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DO conductors, when installed according manufacturer's instructions. I No enforced DC/AC ratio. See the compafibihty calculator at _dnjQ-_c - rinnlhadroLlty 2 Nominal voltage range can be extended beyond nominal if required by the utility. 3 Limits may vary. Refer to local requirements to define the number of rnicroinverters per branch in your area "`�ENPHASE To learn more about Enphase offerings, visit enphase.com To learn more about Enphase offerings, visit enphilase.com ENPHASE / Al r,Lht i E: 1:;,� n IC) on it I'i -n��­­ nku,tin, i(" n,()y, d ad _m_ir­ r ;."r r-ri,s o.­ Fr -,, "i kv, her"" Data Sheet Enphase Networking '1" 1-20®3®ES m1 p 1-2 0-3 -ES l""1 J X-IQ-AMI-240-3-ES LISTED To learn more about Enphase offerings; visit enphasexom The Enishase IQ Combiner 3-E / 3 S"' with Enphase IQ Envoy"' and integrated !_TE-M1 cell modem (included only with lQ Combiner 3C- ES) Consolidates interconnection equipment into a single enclosure and streamlines PV and storage installations by providing a consistent, pre -wired solution for residential applications. it offers Up to four 2-pole input Circuits and Eaton BR series busbar assembly. Includes IQ Envoy for communication and control Includes LTE-M1 cell modern (included only with IQ Combiner 3C-ES) Includes solar shield to match Ensemble esthetics and deflect heat Flexible networking supports Wi—Fi, Ethernet, or cellular Optional AC receptacle available for PL.0 bridge Provides production metering and consumption monitoring Reduced size from IQ Combiner+ (X-IQ-AM1-240-2) Centered mounting brackets support single stud mounting Supports back and side conduit entry Up to four 2-pole branch circuits for 240 VAC p3ug-in breakers (not included) 80 A total PV or storage branch circuits Durable NRTL-certified NEMA type 3R enclosure Five-year limited warranty Two years labor reimbursement program coverage included for both the Combiner SKU's UL listed .01 Enphase IQ Combiner -ES 13 ®ES MODEL NUMBER IQ Combiner 3C-ES (X-IQ-AM1-240-3C-ES) IQ Combiner 3C-ES with Enphase IQ Envoy printed circuit board for integrated revenue grade PV production metering (ANSI C12.20+/-0.5°i) and consumption monitoring (+/-2.5%). Includes Enphase Mobile Connect LTE-M1 (CELLMODEM-MI), a plug -and -play industrial -grade cell modem for systems up to 60 microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area.) Includes a silver solar shield to match the Encharge storage system and Enpower smart switch and to deflect heat. ACCESSORIES and REPLACEMENT PARTS (not included, order separately) Circuit Breakers Supports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers. BRK-10A-2-240 Circuit breaker, 2 pole, 10A, Eaton BR210 BRK-15A-2-240 Circuit breaker, 2 pole, 15A, Eaton BR215 BRK-20A-2P-240 Circuit breaker, 2 pole, 20A, Eaton BR220 EPLC-01 Flower lure carrier (cor annunicatian bridge pair), quantity -cane pair XA-SOLARSHIELD-ES Replacement solar shield for Combiner 3-ES / 3C-ES A-PLL3C 124w3 Accessory receptaclefor Power Line Carrier to IQ ornbiner 2l-ES / 3C-ES (required for EPLC-03) XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board (PCB) for Combiner 3-ES / 3C-ES ELECTRICAL SPECIFICATIONS Production metering CT 200 A solid core pre -installed and wired to IQ Envoy Consumption monitoring CT (CT-200-SPLIT) 'A pair of 200 A split care current transformers, MECHANICAL DATA Weight 7.5 kg (16.5 Ibs) Ambient temperature range -401 C to a461 C (-400 to 115° F) Cooling Natural convection plus heat shield Enclosure environmental rating Outdoor, tRTL-certified, NEMA type 3R, polycarbanate construction Wire sizes 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors 60 A breaker branch input: 4 to 1/0 AWG copper conductors Main lug combined output: 10 to 2/0 AWG copper conductors Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. Attitude To 200O meters (6,560 feet) INTERPRET CONNECTION OPTIONS Cellular CELLMODEM-Ml-06 4G based LTE-M1 cellular modem (included only with IQ Combiner 3C-ES). Note that an Enphase Mobile Connect cellular modem is required for all Ensemble installations. Compliance, IQ Envoy UL 60601-1/CANCSA 22.2 No, 61010-1 To I learn more about En phase offerings visit enphaseerrs nENPHASE ,i; F- -rr �, 'igt 7 c E„ ;r4 n,, >e. ,r�:�r, I,. t�i .,i•us _ ...... ,�. ., .>_ ,i.. rues � 26 AW IRON RIDGE XR Rail Family XR Rail Family Solar Is Not Always Sunny Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. A XR Rails are the structural backbone preventing these results. They resist uplift, protect against buckling and safely and efficiently transfer loads into the building structure. ` Their superior spanning capability requires fewer roof attachments, reducing the number of roof penetrations and the amount of installation time. Sloped roofs generate both vertical and lateral forces on mounting rails which can cause them to bend and twist. The curved shape of XR Rails is specially designed to increase strength in both directions while resisting the twisting. This unique feature ensures greater security during extreme weather and a longer system lifetime. Compatible with Flat & Pitched Roofs XR Rails are IronRidge offers 2 compatible with a range of tilt leg I FlashFoot and options for flat other pitched to of roof mounting attachments. applications. I I All XR Rails are made of 6000-series aluminum alloy, then protected with an anodized finish. Anodizing prevents surface and structural corrosion, while also providing a more attractive appearance. I K. XR10 is a sleek, low -profile mounting rail, designed for regions with light or no snow. It achieves spans up to 6 feet, while remaining light and economical. 6'spanning capability Moderate load capability Clear & black anodized finish Internal splices available NXIMM47 mo XR100 is the ultimate residential mounting rail. It supports a range of wind and snow conditions, while also maximizing spans up to 10 feet. 10' spanning capability Heavy load capability Clear & black anodized finish Internal splices available MIT= XR1000 is a heavyweight among solar mounting rails. It's built to handle extreme climates and spans up to 12 feet for commercial applications. 12'spanning capability Extreme load capability Clear anodized finish Internal splices available 'Table is meant to be 3 simplified span chart for conveying general rail capabilities. Use approved certification letters for actual design guidance.