HomeMy WebLinkAbout22-3893City of Zephyrhills
1,00
V 10
1111.
5335 Eighth Street
Zephyrhills, FL 33542
ELCMISC-003893-2022
Phone: (813) 780-0020
Fax: (813) 780-0021
Issue Date: 04/12/2022
12 26 21 006B 00000 0220 5644 Cypress Street
Name: STACY & STEVEN PFENNIG Permit Type: Electric Service Replacement/M Contractor: MERAKI INSTALLERS LLC
Class of Work: Add/Alter Residential
Address: 5644 Cypress St Building Valuation: $0.00
ZEPHYRHILLS, FL 33542 Electrical Valuation: $21,000.00
Phone: (813) 708-2045 Mechanical Valuation: ....... . ..
Plumbing Valuation:
2 . ... ..
Total Valuation: $21,000.00
4—
Total Fees: $145.00
Amount Paid: $145.00
Date Paid: 4/1212022 12:22:03PM
REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection, whichever is greater, for each subsequent reinspection.
Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies.
jgz��� 11 1 11 lll�pllplill I lli�lllp I I 111 !111 1 Jill "1740 NJ=. = �
23131•��
Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CONTRACTOR I oR SIGNATURE
-�- WA� Z -
PEfFT&FIFI'6E19
THOUT APPROVED INSPECTION
,W rT 1111 F;T*- I j I Z 1 .1 : I
WKSMER4 TIM M"��
DocuSign Envelope ID: 374BCB14-57F2-4C20-835E-DB8286CF688FN Y, hills Permit Application
u `� Building Department
Fax-813-780-0021
Date Received
Phone Contact for Permitting )
tt ttttt t
Owner's Name Steven Pfenni g Owner Phone Number (813) 708-2045
Owner's Address 5644 Cypress St. Zephyrhills, FL 33542 Owner Phone Number
Fee Simple Titleholder Name Owner Phone Number—�
Fee Simple Titleholder Address
JOB ADDRESS 5644 Cypress St. Zephyrhills, FL 33542 LOT#
SUBDIVISION YINGLING ADDITION PARCEL ID# 12-26-21-0063-00000-0220
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED B NEW CONSTR 8 ADD/ALT SIGN DEMOLISH
INSTALL REPAIR
PROPOSED USE F_x__1 SFR COMM OTHER
TYPE OF CONSTRUCTION BLOCK FRAME STEEL
DESCRIPTION OF WORK PV Solar Installation / System Size: 7.665 kW DC
BUILDING SIZE I i SO FOOTAGE HEIGHT [�=
CXXXL£-€VLtt;:.J.tC
=BUILDING ($ VALUATION OF TOTAL CONSTRUCTION
=ELECTRICAL $ { AMP SERVICE PROGRESS ENERGY W.R.E.C.
! ? m rt
=PLUMBING
=MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION JI'
GAS ROOFING SPECIALTY = OTHER~
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO 14- 3
V51, .;
BUILDER l" — --_
COMPANY
SIGNATURE
I REGISTERED
Address 21 NWrrin ton Rd
ELECTRICIAN
COMPANY
SIGNATURE
REGISTERED
Address 21 N New Warrington d
PLUMBER
COMPANY
SIGNATURE
REGISTERED
Address
MECHANICAL
COMPANY
SIGNATURE
REGISTERED
Address
OTHER
COMPANY
SIGNATURE
REGISTERED
Address
Meraki Installers
Y/ N FEE CURREN Y I N
License # CVC57044
Merck, Installers
Y L N FEE CURREN I Y/ N
License # EC0000525
Y / N
FEE CURREN
Y� / N
License #
Y / N
FEE CURREN
Y / N
License #
Y / N
FEE CURREN
Y / N
License #
iYiii#lFi3iit#ti�i#ititi#ilk[#iti#lEii�lEllia!#iEiBlilttiiilltltitEiitt�t
RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms, R-O-W Permit for new construction.
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects
COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction.
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance
SIGN PERMIT Attach (2) sets of Engineered Plans.
****PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner & Contractor sign back of application, notarized
If over $2500, a Notice of Commencement is required. (A!C upgrades over $7500)
Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage)
Driveways -Not over Counter if on public roadways..needs ROW
DocuSign Envelope ID: 374BCB14-57F2-4C20-835E-DB8286CF688Fr y hills Permit Application
Building Department
Fax-813-780-0021
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive
than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they
may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and
contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements
may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009.
Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the 'contractor Block" of this
application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is
not entitled to permitting privileges in Pasco County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or
expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that
such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery
Fees must be paid prior to receiving a 'certificate of occupancy' or final power release. If the project does not involve a certificate of occupancy or final
power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior
to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant,
have been provided with a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide' prepared by the Florida Department of
Agriculture and Consumer Affairs. If the applicant is someone other than the "owner, I certify that I have obtained a copy of the above described
document and promise in good faith to deliver it to the "owner" prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with
all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as
indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all
laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I
understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I
must take to be in compliance. Such agencies include but are not limited to:
Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
Southwest Florida Water Management District -Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
Army Corps of Engineers -Seawalls, Docks, Navigable Waterways.
Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment,
Septic Tanks.
US Environmental Protection Agency -Asbestos abatement.
Federal Aviation Authority -Runways.
I understand that the following restrictions apply to the use of fill:
Use of fill is not allowed in Flood Zone W" unless expressly permitted.
If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to
commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or
other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as
authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from
thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work
authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a
period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to
exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered
abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
(F.S. 117.03)
OWNER OR AGENT
Subscribed and sworn to (or affirmed) before me this
Who is/are personally known to me or has/have produced
as identification.
Notary Public
Commission No
CONTRACTOR
Subscribed and sworn t or affirmed) before me this
by
Who is/are personally known to me or has/have produced
as identification.
Notary Public
Commission No. GG950846
Coti Miller
Name of Notary typed, printed or stamped Name of Notary typed, printed or stamped
.,COTI MILLER
Notary Pioblic-State of Florjdj
g iurt1rrtil31kn E GC;"0640
et'Z AEy C r�rrar,a3er )`aprrfgi
Januery 26, Z024
76 North Meadowbrook Drive
Alpine, UTB4004
office (20Y)874-3483
awynaling@w9om&nDoonsuftinA.00m
Jacob Humpherys, COO
Meraki Solutions
Re: Engineering Services
Pfenning Residence
5844 Cypress Street, ZephyrhiUaFL
7.665 kW System
To Whom It May Concern:
We have received information regarding solar installation on the roof ofthe above referenced
structure. Our evaluation of the structure is to verify the existing capacity of the roof system and its ability
to support the additional loads imposed by the proposed solar system.
1 Site visit documentation identifying attic information including size and spacing of framing
for the existing roof structure.
Z Design drawings of the proposed system including e site plan, roof plan and connection
details for the solar panels. This information will beutilized for approval and construction
ofthe proposed system.
Roof Framing:
Prefabricated wood busses with all buea members constructed of x4
dimensional lumber at24^nncenter.
Roof Material:
Composite Asphalt Shingles
Roof
23degneea
Attic Access:
Accessible
Foundation:
Permanent
� Dead Load
o Existing Roofing and framing 7 psf
o New Solar Panels and Racking =3psf
o TDTAL=10PSF
° Live Load =20 psf (reducible)—Opsf at locations of solar panels
° Ground Snow Load =Dpa
• Wind Load based onASCE74G
o U|dmateV0nd Speed = 160 mph (based on Risk Category ||)
u Exposure Category C
Analysis performed of the existing roof structure utilizing
1. The solar panels shall be mounted in accordance with the most recent Ironridge installation
manual. If during solar panel installation, the roof framing members appear unstable or deflect
non -uniformly, our office should be notified before proceeding with the installation.
2. The maximum allowable withdrawal force for e5/m~lag io235|bsper inch ofpenetration an
identified in the National Design Standards (NDS) of timber construction specifications. Based on
minimum ena1ration depth of21/2" the allowable capacity per connection is greater than the
design withdrawal force (demand). Considering the variable factors for the existing roof framing
and installation to|enanoee, the connection using one 5//6^ diameter lag screw with e minimum of
2'/2"embedment will beadequate and will include aouffinientfecbzrof
3. Considering the wind speed, roof slopes, i and spacing of framing membero, and condition of
the roof, the panel supports shall baplaced nn greater than 48^oncenter.
4. Panel supports connections shall be staggered to distribute load to adjacent framing members.
Based onthe above evaluation, this office certifies that with the racking and mounting specified, the existing
roof system will adequately support the additional loading imposed by the solar system. This evaluation is in
conformance with the FBC 20207m Edition, current industry standards, and is based on information supplied
touoat the time ofthis report.
Should you have any questions regarding the above or if you require further information do not hesitate to
contact me.
luly
A__ ?. U
Scott E. Wyssli PE
Florida License �Noo
Date signed 4/7/22
F-11ULAMILTIMMI
• k �
EQUIPMENT1. INSTALLATION OF SOLAR PHOTOVOLTAIC SYSTEM SHALL BE IN ACCORDANCE WITH NEC ARTICLE
690, AND ALL OTHER APPLICABLE NEC CODES WHERE NOTED OR EXISTING.
2. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL
COMPLY'
WIRES,1 ALL r GROUNDING ELECTRODE • r •R SHALL BE PROTECTED FROM
PHYSICAL DAMAGE IN ACCORDANCEARTICLE
4. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE; THIS SYSTEM IS UTILITY INTERACTIVE PER
UL /. t . . D DOES NOT INCLUDERA BATTERIES O • OTHER ALTERNATIVE STORAGE SOURCES.
5. ALL DC WIRES SHALL BE SIZED ACCORDING TO .'f
.81
. DC CONDUCTORSABE PROTECTED RACEWAYS IN ACCORDANCE •.r
.311
TO :; PLACED IN ACCORDANCE i.L JURISDICTIONAL BUILrCODE.
Meraki Installers I
484-663-3792
Warrington -•
Pensacola, f
SITE INFORMATION
Steven Pfennig
5644 Cypress St
Zephyrhills, FL 33542
AC SYSTEM SIZE: 6 kW AC
yr;
DC SYSTEM SIZE: 7.665 kW DC
Lat, 28.240086
Long,-82.1684101
r
(21) Suntech STPXXXS - B60/Wnhb 365 PV
{
MODULES
(11SolarEdge SE600OH-US (240V) INVERTER(S)
PHOTOVOLTAIC (PV) SYSTEM SPECIFICATIONS TE OF
k a
DC SYSTEM SIZE: 7.665 kW DC Wyssling Consulting, PLLC
SolarEdge 600O/ INVERTER(S)
/ Date signed 4/7/22
2017 NEC
2020FFPC
2020 FBC 7TH EDITION, BUILDING
2020 FBC 7TH EDITION, RESIDENTIAL
2020 FBC 7TH EDITION, EXISTING BUILDING
•: /
• r:
Duke Energy
r
PV01
COVERPAGE
PV02
SITE PLAN
PV03
ROOF ATTACHMENTS
•/
MOUNTING DETAIL
PV05
LINE DIAGRAM
r f•
ELECTRICAL CALCS
PV07
LABELS
V 0
PLACARD
PV09
SITE PHOTOS
DRAWN BY: SOIoCAD
DATE:
April 4, 2022
COVER PAGE - PV01
ARRAY DETAILS:
MOUNTING PLANE:
AZIMUTH:
TILT:
in
EQUIPMENT LEGEND:
VISIBLE, LOCKABLE, LABELED —V] INVERTER SUB PANEL FIRE ACCESS PATHWAY (TTYP) [BA� BATTERY(I
m I UTILITY METER IN ES)
E AC DISCONNECT F FBI
METER SOCKET
MAIN SERVICE PANEL PV I COMBINER BOX LOAD CENTER PROPERTY LINE
LOCATED WITHIN 10'
OF UTILITY METER
ffleraki Installers
484-663-3792
Pensacola, FL 32507
StevenPfenrig
5644Cypress St
zcpxv/hiUs'pL33S4z
ACSYSTEM SIZE: 6 kvvAc
oCSYSTEM SIZE: 7.665WwoC
uatz8.24OO86
Long''8zz684zUz
(zz) suntech5rpxxxs a60/vvnhb365 pv
xxOoU/B
(1)so|arEuaeSc600on'us(240v)|mvsnTen(s)
DRAWN BY: SoloCAD
DATE
SITE PLAN - PV02
W-11411
111114MINK414EM, MID] ".*
0__jND CLAMP DETAILS�
MID CLAMP
PV MODULE FRAME
IRONRIDGE XR-100 RAIL
D
PV MODULE
IRONRIDGE XR-100 RAIL
19W.1y'll .1 MlIM-11110 1,11141121610 1
(E) COMP SHINGLE ROOF (1 LAYER)
FLASHVUE ATTACHMENT
(E) RAFTER/TOP CHORD
FLASHING (SEE DATASHEET FOR DETAILS)
5/16" STAINLESS STEEL LAG BOLT
WITH 2-1/2" MIN. EMBEDMENT
(PER MANUFACTURER)
(E) RAFTER/TOP CHORD
DETAIL, MOUNTING AND FLASHING I
9
EQUIPMENT INFORMATION:
ROOF INFO:
PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA:
RAIL MANUFACTURER:
IronRidge
ROOF TYPE:
Asphalt Shingle
PV MODULE COUNT:
21
RAIL PART NUMBER:
XR-100
ROOF FRAMING:
Manufactured Truss
ARRAY AREA:
MODULE COUNT* 19.64 ft2 = 412.44
ATTACHMENTS
FlashVue
RAFTER/TOP CHORD SIZE:
2x4
ROOF AREA:
2520.222 ft2
ATTACHMENT CITY:
45
RAFTER/TOP CHORD SPACING:
24"
PERCENT OF ROOF COVERED:
16%
SPLICE CITY:
6
ATTACHMENT SPACING: 4(3:
48"
ARRAY WEIGHT:
MODULE COUNT * 45 lbs = 945 lbs
MIDCLAMP CITY:
34
DISTRIBUTED LOAD:
ARRAY LBS/ATTACHMENTS = 21
ENDCLAMP CITY:
16
POINT LOAD: (IbS/ft2)
(ARRAY) WEIGHT/AREA = 2.29 ]bS/ft2
MEFRAKI
ZERO DOWN SOLAR
CONTRACTOR INFORIVIATION'
[Tieraki Installers
484-663-3792
21 N New Warrington R4
Pensacola, FIL 32507
License # CVC57044
SITE INFORMATION
Steven Pfennig
5644 Cypress St
Zephyrhills, FL 33542
AC SYSTEM SIZE: 6 kW AC
DC SYSTEM SIZE: 7.665 kW DC
Lat, 28.240086
Long, -82.1684101
(21) Suntech STPXXXS - B60/Wnhb 365 PV
MODULES
(1) SolarEdge SE600OH-US (240V) INVERTER(S)
ergy
ItIII,
Duke
't
Suntech STPXXXS - B60/Wnhb 365 Specs
POWER MAX (PMAX):
365W
OPEN CIRCUIT VOLTAGE (VOC):
38.5V
MAX POWER -POINT CURRENT (IMP):
10.71A
MAX POWER -POINT VOLTAGE (VMP):
34.1V
SHORT CIRCUIT CURRENT (ISC):
11.42A
SERIES FUSE RATING:
20 A
STRING (1): 15.0 A DC
SolarEdge SE6000H-US(240V)Specs
MAX INPUT VOLTAGE:
480 V
MAX INPUT CURRENT:
16.5 A
NOMINAL DC INPUT VOLTAGE:
380 V
MAXIMUM OUTPUT POWER:
6000 W
NOM. OUTPUT VOLTAGE:
240 V
MAX OUTPUT CURRENT:
25 A
1-Phase, 60 HZ, UL 1741 Listed
Equipment Schedule
TYPE:
QTY:
DESCRIPTION: RATING:
MODULES:
(21)
Suntech STPXXXS - B60/Wnhb 365 365 W
INVERTERS:
(1)
SolarEdge SE6000H-US (240V) 6000 W
AC DISCONNECTS:
(1)
PV AC Disconnect, 240V, 2-Pole 60 A
DC OPTIMIZERS:
(21)
SolarEdge P370 15 Adc
Conduit & Conductor Schedule
TAG
QTY
WIRE GAUGE
DESCRIPTION
CONDUIT SIZE
(2)
10 AWG
PV-WIRE, USE-2, COPPER (Ll, L2)
i
(1)
6AWG
THWN-2COPPER -(GROUND)
N/A -FREE AIR
(2)
10AWG
THHN/THWN-2,- (L1,12)
2
(1)
10 AWG
THWN-2 COPPER - (GROUND)
3/4"EMT
14)
10 AWG
THHN/THWN-2, COPPER -(L1, L2)
3
(1)
10 AWG
THWN-2 COPPER - (GROUND)
3/4^EMT
(3)
8 AWG
THWN-2 COPPER - (Ll, L2, NEUTRAL)
4
(1)
10 AWG
THWN-2 COPPER - (GROUND)
3/4" EMT
(E) UTILITY METER
(E) GROUNDING
ELECTRODE
E = 1 � M
LOCATED WITHIN 10'
OF UTILITY METER
Meraki Installers
III I III �
II.. •
Pensacola,
er
License # i
l
Steven Pfennig
5644 Cypress St
Zephyrhills, FL 33542
AC SYSTEM SIZE: 6 kW AC
DC SYSTEM SIZE: 7.665 kW DC
Lat, 28.240086
Long,-82.1684101
(21) Suntech STPXXXS - B60/Wnhb 365 PV
MODULES
(1) SolarEdge SE600OH-US (240V) INVERTER(S)
Duke En y
7rr22s
°F
DRAWN BY: SOIOCAD
DATE:
April 4, 2022
LINE DIAGRAM - PV05
STRING CALCULATIONS
SolarEdge SE6000H-US (240V)
STRING #1
STRING #2
OPTIMIZER MAX OUTPUT CURRENT
15A
15A
OPTIMIZERS IN SERIES:
11
10
NOMINAL STRING VOLTAGE:
380V
380V
ARRAY OPERATING CURRENT:
11A
10A
ARRAY DC POWER:
7665W
TOTAL MAX AC CURRENT:
25A
NUMBER OF CURRENT CARRYING CONDUCTORS
PERCENT OF VALUES
4-6
.80
7-9
.70
10-20
.50
SYSTEM OCPD CALCULATIONS
INVERTER MODEL(S):
SolarEdge SE6000H-US (240V)
# OF INVERTERS:
1
MAX OUTPUT CURRENT:
25A
(# OF INVERTERS) X (MAX OUTPUT CURRENT) X 125% <= OCPD RATING
(1 X 25A X 1.25) = 31.25A <= 35A, OK
BUSBAR CALCULATIONS - 120%RULE
MAIN BUSBAR RATING: 200A
MAIN DISCONNECT RATING: 200A
PV BREAKER RATING: 35A
(MAIN BUS RATING X 120%) - MAIN DISCONNECT RATING >= OCPD RATING
(200A X 1.2) - 200A = 40A, >= 35A, OK
Conduit & Conductor Schedule
TAG
CITY
WIRE GAUGE
DESCRIPTION
CONDUIT SIZE
CONDUCTOR RATING
CONDUCTOR TEMP. RATE
AMBIENT TEMP
TEMP. DERATE
# OF CONDUCTORS
DERATE
CONDUCTOR RATING
W/DERATES
CONDUIT FILL
1
(2)
10 AWG
PV-WIRE , USE-2, COPPER (L1, L2)
N/A - FREE AIR
40A
90°C
33°C
0.96
N/A - FREE AIR
38AA
N/A - FREE AIR
(1)
6 AWG
THWN-2 COPPER - (GROUND)
2
(2)
10 AWG
THHN/THWN-2, COPPER - (L1, L2)
3/4" EMT
40A
90°C
33°C
0.96
1
38.4A
11.9%
(1)
10 AWG
THWN-2 COPPER - (GROUND)
3
(4)
10 AWG
THHN/THWN-2,COPPER -(L1,L2)
3/4" EMT
40A
90°C
33°C
0.96
0.8
30.72A
19.$%
(1)
10 AWG
THWN-2 COPPER - (GROUND)
4
(3)
8 AWG
THWN-2 COPPER - (L1, L2, NEUTRAL)
3/4" EMT
50A
75°C
33°C
0.96
1
48A
24.6%
(1)
10 AWG
-
I THWN-2 COPPER (GROUND)
GROUNDING & GENERAL NOTES:
1. PV INVERTER IS UNGROUNDED,TRANSFORMER-LESS
2. DC GEC AND AC EGC TO BE SPLICED TO EXISTING ELECTRODE
3. ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION• •
INADEQUATEBE •• •.. • PRIOR TO FINAL INSPECTION.
JUNCTION4. BOX QUANTITIES,AND PLACEMENT
JUNCTION• DEPICTED ON DIAGRAM
TRANSITIONS,
5. AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER
AC DISCONNECTING MEANS IS LOCATED WITHIN 10'OF SERVICE DISCONNECT.
INTERCONNECTION NOTES:
1. INTERCONNECTION SIZING, LIMITATIONS AND COMPLIANCE DETERMINED IN ACCORDANCE WITH [NEC
705.121, AND [NEC 690.64].
2. GROUND FAULT PROTECTION IN ACCORDANCE WITH [NEC 215.9], [NEC 230.95] AND [NEC 690.51
3. ALL EQUIPMENT TO BE RATED FOR BACKFEEDING.
4. PV BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE BUSBAR RELATIVE TO THE MAIN BREAKER.
DISCONNECT NOTES
1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS
REMAINING LIVE ARE CONNECTED TO THE TERMINALS MARKED "LINE SIDE" (TYPICALLY THE UPPER TERMINALS)
2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A
VISIBLE -BREAK SWITCH
Meraki Installers
+s s
Warrington
License # 1
Pensacola,4
Steven Pfennig
5644 Cypress St
Zephyrhills, FL 33542
AC SYSTEM SIZE: 6 kW AC
DC SYSTEM SIZE: 7.665 kW DC
Lat, 28.240086
Long,-82.1684101
(21) Suntech STPXXXS - B60/Wnhb 365 PV
MODULES
(1) SolarEdge SE600OH-US (24CV) INVERTER(S)
, *r zq
J y� ✓
o.
STATE OF °yam
R 1 „< °'°
ys ling Consulting, PLLC
76 N Meadowbrook Drive Alpine UT 84004
Florida license # RY34412
Date signed 4/7/22
DRAWN BY: SoloCAD
DATE:
April 4, 2022
ELECTRICAL CALLS - PV06
ELECTRIC SHOCK HAZARD
• l I
• . a
MAIN SUPPLY OVERCURRENT
DEVICE, tt{{ •
T EXCEED
J..It `
ACITY OF BUSBAR.
LABEL 1
FOR PV DISCONNECTING MEANS WHERE THE LINE AND
LOAD TERMINALS MAY BE ENERGIZED IN THE OPEN
POSITION.
[NEC 690.13(B)]
LABEL 2
PLACED ADJACENT TO THE BACK -FED BREAKER FROM
THE INVERTER IF TIE IN CONSISTS OF LOAD SIDE
CONNECTION TO BUSBAR.
[NEC 705.12(B)(2)(3)(b)]
(tT LABEL 3
Y� PLACED ADJACENT TO THE BACK -FED BREAKER
FROM THE INVERTER IF TIE IN CONSISTS OF LOAD
!INViRTER OUTC ECTI SIDE CONNECTION TO BUSBAR.
[NEC 705.12(13)(2)(3)(c)]
DO ROT RELOCATE
THIS OVERCURRENT
DEVICE
LABEL 4
EQUIPMENT CONTAINING OVERCURRENT
DEVICES IN CIRCUITS SUPPLYING POWER TO A
BUSBAR OR CONDUCTOR SUPPLIED FROM
MULTIPLE SOURCES SHALL BE MARKED TO
INDICATE THE PRESENCE OF ALL SOURCES
[NEC 705.12(B)(3)]
LABELS
AT POINT OF INTERCONNECTION, MARKED AT
AC DISCONNECTING MEANS.
[NEC 690.54, NEC 690.13 (B)]
LABELING NOTES:
1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT
REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS.
2. LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRIC CODE, OSHA STANDARD 19010.145, ANSI
Z535.
3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION,
4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [NEC 110.21(B)(3)]
5. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, AND
PERMANENTLY AFFIXED [IFC 605.11.1.11
INTEGRATED DC DISCONNECT
MAIN SERVICE PANEL
y
' i ► ii
SWICH TO i
POSITION i SHUT ii '
PV SYSTEM AND
REDUCE
SHOCK HAZARD IN ARRA
11
LABEL 6
AT DIRECT -CURRENT EXPOSED RACEWAYS, CABLE TRAYS, COVERS AND
ENCLOSURES OF JUNCTION BOXES, AND OTHER WIRING METHODS; SPACED
AT MAXIMUM 10FT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS,
PARTITIONS, CEILINGS, OR FLOORS.
[NEC 690.31(G)(3&4)]
LABEL 7
FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING
THE ARRAY:
SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE
DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND
SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN
SWITCHES IF NOT AT THE SAME LOCATION.
[NEC 690.56(C)(1)(A)]
LABEL8
AT EACH DC DISCONNECTING MEANS [NEC 690.53]
LABEL 9
SIGN LOCATED AT RAPID SHUT DOWN
DISCONNECT SWITCH [NEC 690.56(C)(3)].
O(4
LABELING DIAGRAM:
EXISTING SUB PANEL PV COMBINER
(IF WHERE POINT OF SUBPANEL -
INTERCONNECTION IF USED TO COMBINE
IS MADE) AC DISCONNECT PV OUTPUT CIRCUITS
INVERTER (S)
❑❑❑
O O O CQ
CO
00 a
4
O
HDC
JUNCTION BOX
OR COMBINER BOX
(ONLY
(ONLY IF PV
0
INTERCONNECTION
ECC TION
CONSISTS OF LOAD
INTERCONNECTION
CONSISTS OF LOAD
�� O
(D O
SIDE BREAKER)
SIDE BREAKER)
*ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS
PRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON THE ELECTRICAL DIAGRAM PAGE.
r � a
Meraki Installers
484-663-3792
Warrington R4
Pensacola, 0
License # •• !••
Steven Pfennig
5644 Cypress St
Zephyrhills, FL 33542
AC SYSTEM SIZE: 6 kW AC
DC SYSTEM SIZE: 7.665 kW DC
Lat, 28.240086
Long,-82.1684101
(21) Suntech STPXXXS - B60/Wnhb 365 PV
MODULES
(1) SolarEdge SE600OH-US (240V) INVERTER(S)
STATE OF
r"
OR
pr'
DRAWN BY: SOIoCAD
DATE:
April 4, 2022
LABELS - PV07
CAUTION
POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR
ARRAYS WITH SAFETY DISCONNECTS AS SHOWN:
N
AC DISCONNECT
INVERTER & RAPID
SHUTDOWN DC
r M TAC NDISCONNECT SWITCH
MAIN DISTRIBUTION
QSP 0
UTILITY DISCONNECT
0
0
0
0
00
0
U-
0
0
00
z
0
0
LL-
PV ARRAY
5644 Cypress St, Zephyrhills FL 33542
!1�Ii Ill ImqiII!1q;
•x kill- I im leiiiiaivitinvii
(ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS OUTLINED WITHIN:
NEC 690.56(B)&(C), [NEC 705.10])
Meraki Installers
484-663-3792
21 N New Warrington Rd
a
Pensacola, FL 32507
License # CVC57044
k1ft4[ffm*1aI&+ #X11
Steven Pfennig
5644 Cypress St
Zephyrhills, FL 33542
AC SYSTEM SIZE: 6 kW AC
DC SYSTEM SIZE: 7.665 kW DC
Lat, 28.240086
Long, -82.1684101
(21) Suntech STPXXXS - B60/Wnhb 365 PV
MODULES
(1) SolarEdge SE600OH-US (240V) INVERTER(S)
4 " , I
N( 11' V'8
STATE OF
$
,,,S/ONA6o"
, /1111111111101110
Wyssling Consulting, PLLC
76 N Meadowbrook Drive Alpine UT 84004
Florida License # RY34912
Date signed 4/7/22
DRAWN BY: SoloCAD
DATE:
Apri14,2022
PLACARD - PV08
CONTRACTOR INFORMATION:
Meraki Installers
484-663-3792
21 N New Warrington Rd
Pensacola, FL 32507
StevenPfen,ig
s644Cypress m
zephv,hi||s'p|sss42
AC SYSTEM SIZE: 6 kW AC
oCSYSTEM SIZE: 7.665kwoc
Lor�-82.16B410z
(21) suntechSTPxxxS o60/vvohb365 pv
xxoou|Es
STATE OF
Florida License # RY34912
Date signed 4/7/22
DRAWN BY: SoloCAD
SITE PHOTOS - PV09