HomeMy WebLinkAbout22-3905it of Zephyrhill s
M
5335 Eighth Street
Zephyrhills, FL 33542
BGC-003905-2022
Phone: (813) 780-0020
Fax: (813) 780-0021
Issue Date: 06/13/2022
k=j, agril 11•1q
... .. . ... .
1126 210010 16700 0055
38434 5Th Avenue
Name: AGHAPY PROPERTIES LLC
Permit Type: Building General (Commercial)
Contractor: SIGN A RAMA OF NEW
Class of Work: Wall Sign
TAMPA
Address: 445-21 St Ct Sw
Building Valuation: $2,400.50
VERO BEACH, FL 33542
Electrical Valuation: $1.00
Phone: (352) 678-8609
Mechanical Valuation: $1.00
Plumbing Valuation: $1.00
Total Valuation: $2,403.50
I
Total Fees: $78.00
Amount Paid: $78.00
Date Paid: 6/13/2022 2:22:49PM
INSTALLATION WALL NON -ILLUMINATED SIGNAGE PLANET JUNIPER
Building Plan Review Fee $26.00 Building Permit Fee $52.00
REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection, whichever is greater, for each subsequent reinspection.
Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies.
CONTRACTOR SIGNATURE
M-TU T-71 17 10, MMITI 17-7 TIA
g"
PEfIT OFFICEU
I Fee $;m*IPT1lehoIfr4A4
P Owner Phone Number
Fee Simple Titleholder Address �-k5A CT 'FL
JOB ADDRESS 38438 5th Ave. Zephyrhills, FL 33542 LOT #
SUBDIVISION PARCEL ID# 11-26-21-0010-16700-0055
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED NEW CONSTRe
ADD/ALT SIGN DEMOLISH
R INSTALL REPAIR
PROPOSED USE SFR � Comm OTHER
TYPE OF CONSTRUCTION BLOCK F--] FRAME STEEL
DESCRIPTION OF WORK Nan Illuminated Wall Sign
BUILDING SIZE $Q FOOTAGE I HEIGHT
[X--]BUILDING $ 2,400.50 VALUATION OF TOTAL CONSTRUCTION
=ELECTRICAL
=PLUMBING
=MECHANICAL
= GAS
N E R GYj W.R.E.C.
C 4(
4s,
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO
BUILDER f COMPANY _5janarama of New Tampa
REGISTER
ED RED L)�l �N FEE CURREN Y/N
Address�,�] 1917 Passes Ave. Lutz, FL 33559 License #
ELECTRICIAN COMPANY
SIGNATURE REGISTERED Ly LIN FEE CURREN Y/N
Address License #
PLUMBER COMPANY I
SIGNATURE REGISTERED Y/N FEE CURREN
Address License #
MECHANICAL COMPANY
SIGNATURE REGISTERED YIN FEE CURREN Y/N
Address License#
OTHER COMPANY I
SIGNATURE REGISTERED Y/N FEE CURREN Y/N
Address License #
RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction,
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects
COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction.
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance
SIGN PERMIT Attach (2) sets of Engineered Plans.
****PROPERTY SURVEY required for all NEW construction.
1114 4-fr * Ik %44% S *4 % S S4 41 6+44
Directions:
Fill out application completely.
Owner & Contractor Sion back of armlication. notarized
AMP SERVICE PROGRESS
-4k � "
VALUATION OF MECHANICAL INSTALLATION
ROOFING = SPECIALTY = OTHER
-._''-
pu�»onnova.nmeown",xaxmedaovntracm,mcontrxomrs.oeinauvsoumxavomeuonoanmr(s)nign portions mthe "contractor Block" ofthis
6ppkm6tivn for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is
not entitled topermitting privileges i^Pasco County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or
expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that
such fees, aomay uodue, will ueidentified at the time nrpermitting. kiofurther understood that Transportation Impact Fees and Resource Recovery
Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the projectd not involve acertificate oxoccupancy u,final
power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior
topermit issuance inaccordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant,
have been provided with a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of
Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that | have obtained acopy o,the above described
document and promise in good faith to deliver it to the "owner" prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with
all applicable laws regulating construction, zoning and land development. Application ivhereby made tnobtain apermit »ouvwork and installation ao
indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all
laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I
understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I
must take tnhoincompliance. Such agencies include but are not limited to:
- Department ofEnvironmental Protection -Cypress Beyheado, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
- Southwest Florida Water Management District-Wo||s, Cypress Bayheade, Wetland Areaa, Altering
Watercourses.
- Army Corps ofEngin*era'Soawa||s. Docks, Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-VVe||e, Wastewater Tneatment,
Septic Tanks.
USEnvironmental Protection Agency -Asbestos abatement.
- Federal Aviation Authority-Runvvaya.
| understand that the following restrictions apply tnthe use offill:
Use offill isnot allowed inFlood Zone ''V~unless expressly permitted.
- If the 0| mabahe| is to be used in Flood Zone 'YY', it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which in prepared by professional engineer
licensed bythe State ofFlorida.
- If the DU material is to be used in Flood Zone "A' in connection with a permitted building using stem vvaU
construction, | certify that fill will be used only hofill the area within the stem wall.
If fill material is to be used in any area. | certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent propertien, the nvvn*/ may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots |eea than one (1)
acre which are elevated byfill, anengineered drainage plan ierequired.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to
commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or
other installations not specifically included inthe application. 4permit issued shall ueconstrued \obralicense mproceed with the work and not ov
authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from
thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work
authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a
period o[six (8)months after the time the work iscommenced. An extension may be requested, in writing, from the Building Official for a period not to
exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered
abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT |@YOUR
PAYING TWICE FOR IMPROVEMENTS TOYOUR PROPERTY. |F YOU INTEND TO OBTAIN FINANCING, CONSULT
FLORIDA JUrwn'(rS11703)
Subscribed and sw rr 70-(praffirmed) before me4fiii Subscr� , ibed,;s n to or affirmed) before me this'-'
as identification. r!!� as identification.
OWNER OR AGENT CONTRACTOR
No
Kli
STEPHANIE DAVIS
MY COMMISSION 9GG 333567
EXPIRES: May 13,2023
E:: =
Commission No.
Name of Notary typed, printeo orstamped
20
81EPHANIE DAVIS
ONIMISSION
Conforms to the requirements of the 7th Edition (2020) of the Florida Building Code sections 1609 and 3107, V(ult) = 140 mph, Exposure category= C, Risk category= 11
John J. Orlando T LLC - 165 Old Ridge Road -Macon, GA 31211 -478 731 5394-jjoriando@cox.net - Florida registration# 0044089 job 5322STB sheet I of 2
—1
Elevation Color & Material
=C-O, � Digital Print Vinyl
I
1 1/2"=1'-0"
E:Q:UANTITY: 1 12 SQFT
9 N MOM
p."
sR, 3/8" GALVANIZED LAG 01
B LTS ITH AT LEAST 5"
F E BED ENT INTO
3/8-16 SS TOGGLER ZIP
TOGGLE ANCHORS (BCS)
OR EQUIVALENT
Existing Bldg.
overhang. —
1/4'Thick
aluminum mounting
plate welded to top
of tube frame. Mount
to underside of
building overhang
with fasteners per
fastener schedule.
6 Places per Mounting Detail
Sfll 3mm MaxMetal
Panel with DP
vinyl graphics.
Mount panel to
2" sq. aluminum
frame.
2" sq. aluminum
frame.
Side View 2
1 1/2"=1'-0" L)
A
11.. ST.. iggaramd
The way to grow your business
1917 Passero Ave
Lutz, FL 33559
813.994.0101
www.5 igna ra m a-Newtampa.com
This design is protected by copyright.
Use .1'any part .fthis drawing, either
by concept or duplication is prohibited
without written authorization.
SIGNS WILL COMPLY TO
FLORIDA BUILDING CODE
2020 (7TH EDITION)
UNDERWRITERS ---
U LABORATORIES
nee c
ELECTRIC SIGN f
ES12001403 2017
4e�_ 2mff
I REV. I Description I
Sales Person:
Jeremiah Hoch
Proje
ct Manager:
DD
Designer:
RIF I
E] Approved
E] Approved as Noted
El Revise and Resubmit
Date:
File Name:
14448--Planet Jupiter Max Metal
Sign with Square Tube Frame
Quote #
14448 1
lng►li7►l►imggym
V
0
Job name
Job#
Sign company:
Installation location:
Section 3107 and 1609 of Florida Building Code 2020 and Chapter 30 ASCE 7-16 applies.
Application of wind pressures using the alternative all heights method for components and cladding
Type of structure: ACM under canopy blade sign
Occupancy Category:
Wind velocity (3 sec gust), FBC 2020, section 1609.3:
Wind pressure (qz)
tt
140 i mph
50.2 psf
Net Pressure Coeficient (Cnet) from Figure 30.7-2
Components and cladding not in areas of discontinuity - walls and parapets -1.09
Wind Pressure -54.7
Wind load applied between wall and structure, pulling structure away from wall
Load carried by tension in fasteners connecting structure to wall
maximum height of structure to be attached
- maximum width of structure to be attached
effective projected area factor
projected area of each component to be attached
wind load
allowable tension load per fastener to
even number of fasteners minimum of 2
number of fasteners practically required due to structure shape
weight of structure is approximately
- allowable shear load per fastener to
average shear load per fastener =
Mounting surface construction is:
Use methods:
Method 1 - 3/8-16 SS Toggler zip toggle anchors (BCS)
allowable pull out load = 250 Ibs
allowable shear out load = 125 Ibs
htt s:flto ler.comf dfs/SNAPTOGGLE°laC2%AE-Heavv-C}uty-Toggle-Bolts.gdf
NOTE:. Design assumes that fasteners are installed according to manufacturer's
instructions, using correct size drill.
Method 2 - Lag bolts into framing members.
-use 3/8" galvanized lag bolts with at least 5" of embedment into framing members.
allowable pull out load = 436 pounds
allowable tension load = 680 pounds
Method 3 - 3/8-16 Gr5 through bolts
htt :llwww.tataolsonline.com/u loadsi2661safot data bolt stren the identification. df
clamp load = 4950 Ibs
Method 4 - Hilti 3/8" x 2-1/8" KWIK BOLT TZ2 SS304 WEDGE ANCHOR
ultimate tension load = 1520 Ibs
allowable tension load = 760 Ibs
ultimate shear load = 1685 Ibs
allowable shear load = 842 Ibs
NOTE:. Design assumes at fasteners are installed according to manufacturer's
instructions, using correct �ize drill.
ife k- g :
C Y -1 ,
BUILDING OFFIC
John J. Orlando PE LLC 004408-9
165 Old Ridge Road
Macon, GA 31211 f
(478)731-5394
jjorlando@cox.net
2.00 ft
6.00! ft
2:00
24.0 ft^2
-1313 Ibs
250 I Ibs
-6_
6i
6 Ibs
125 Ibs
16.0 Ibs
C . ;
the Florida Building Cfde NO 0044089
psf
ATE OF
�� � sheet: 2 of 2
rrrrrrrw������