HomeMy WebLinkAbout22-3995Name: SVB Housing, LLC
Address: 2310 West Bristol Ave
Tampa, FL 33609
Phone: (443) 622-6651
6419 Simons Rd 04 26 21 0000 00200 0000
SYSTEMS
C c
City of Zephyrhills
5335 Eighth Street
'W"W
Zephyrhills, FL 33542
FIRE-003995-2022
Phone: (813) 780-0020
Fax: (813) 780-0021
Issue Date: 05/11/2022
Permit Type: Fire
Class of Work: Fire Alarm
Building Valuation: $38,000.00
Electrical Valuation:
Mechanical Valuation:
Plumbing Valuation:
Total Valuation: $38,000.00
Total Fees: $200.00
Amount Paid: $200.00
Date Paid: 5/11/2022 3:26:44PM
REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the
local government shall impose a fee of four times the amount of the fee imposed for the inal inspection or
first reinspection, whichever is greater, for each subsequent reinspection.
Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies.
--
Lh� ra ijg Ivir h4jie-a I
Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
2
CONTRACTOR SIGNATURE��'
PEfIT OFFICEO
2 60,101 IT, STA : A" -
813-780-0020 City of Zephyrhills Permit Application
Fax a 780-0021'
Building Department
t
Date Received —�
Phone Contact for Permitting
S11B Housing, LLC
Owner's Name Owner IS "P uffilder._
Ownees Address 2310 W. Bristol Aue Tampa, FL Owner Phone Number
Fee Simple Titleholder Name N/Owner Phone Number
Fee Simple Titleholder Address
JOB ADDRESS 6419 Simons Rd Zephyrhills, FL 33541 LOT
UJ
SUBDIVISION PARCEL tD# 04_26_21-0000-00200-0Og��
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED \f.! NEW CONSTR ADD/ALT SIGN
INSTALL REPAIR
DEMOLISH
PROPOSED USE SFR COMM OTHER M��-R�slae�crai
0
TYPE OF CONSTRUCTION BLOCK 0 FRAME STEELLLAI
Install i�eW Fire Alarm System
DESCRIPTION OF WORK Y
BUILDING SIZE 3 3tOry � SQ FOOTAGE 32=3g2 HEIGHT 35: �
BUILDING $ VALUATION OF TOTAL CONSTRUCTION
=ELECTRICAL
=MECHANICAL
=GAS ROOFING
FINISHED FLOOR ELEVATIONS
AMP SERVICE PROGRESS ENERGY C._m_J W.R.E.C.
qq.._
VAL-UArION OF MECHANICAL INSTALLATION T
A OTHER Fire Alarm Syst iTl ' � C11 V_
FLOOD ZONE AREA =YEs NO
BUILDER COMPANY
SIGNATURE REGISTERED Y / N FEE CURREN Y / N
AddressLicense #
ELECTRICIAN (! COMPANY
SIGNATURE REGISTERED Y!N eaeuRReh �Y/N
Address License # mmm
PLUMBER ( COMPANY
SIGNATURE I REGISTERED ��Y/NFEE CURREN Y/ N
Address License #
MECHANICAL COMPANY
SIGNATURE REGISTERED [::;; FEE CURREN
Address License # C
OTHER $ c�MPANY Florida Low lJe�itge systems LLB
SIGNATURE d STEREO Y/ N FEE CURREN Y I N
Address 4'02 Cayuga St Tampa, FL 33614 License # �F26Ci017$6
RESIDENTIAL Attach (2) Plot Plans, (2) sets of Building Plans, (1) set of Energy Forms, R-O-W Permit for new construction.
Minimum ten {10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster, Site Work Permit for subdivisions/large projects
COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page, (1) set of Energy Forts. R-O-W Permit for new construction.
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stounwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance
SIGN PERMIT Attach (2) sets of Engineered Plans.
*"'PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner & Contractor sign back of application, notarized
If over $2500, a Notice of Commencement is required. (A/C upgrades over $7500)
Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Remote if shingles Sewers Service Upgrades A/C Fences(PIOVSurvey/Footage)
Driveways -Not over Counter if on public roadways..needs ROW
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive
than County regulations, The undersigned assumes responsibility for compliance with any applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they
may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and
contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements
may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009.
Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this
application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is
not entitled to permitting privileges in Pasco County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or
expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that
such fees, as may be due, Wit be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery
Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final
power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior
to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant,
have been provided with a copy of the "Florida Construction Lien Law —Homeowners Protection Guide" prepared by the Florida Department of
Agriculture and Consumer Affairs, If the applicant is someone other than the "owner', I certify that I have obtained a copy of the above described
document and promise in good faith to deliver it to the "owner' prior to commencement,
CONTRACTOR'$/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with
all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as
indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all
laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I
understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I
must take to be in compliance. Such agencies include but are not limited to:
Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, WaterfWastewater Treatment.
Southwest Florida Water Management District -Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
Army Corps of Engineers -Seawalls, Docks, Navigable Waterways.
Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment,
Septic Tanks.
US Environmental Protection Agency -Asbestos abatement.
Federal Aviation Authority -Runways.
I understand that the following restrictions apply to the use of fill:
Use of fill is not allowed in Flood Zone W" unless expressly permitted.
If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
„compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If Use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued Linder the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the deporting conditions set forth in this affidavit prior to
commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or
other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as
authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a pennit prevent the Building Official from
thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work
authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a
period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to
exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered
abandoned,
OWNER OR AGENT
Subscribed and sworn to (or affirmed) before me this
Who islare personally known to me or has/have produced
as identification.
Public
Commission
Name of Notary typed, printed or stamped—
Preparrd by and after
recording return to-,
I hornas K. Morrison,
12W W Plan St- Skote 100
Tampa_ FL 33006
20220480"152
2', , 2022
4
c"4 b
0 00
Niikki E%q,
P,A,,,ckj C tf"rk Ca�Ialptra I iev
- --- ------
PERMITNO, Parcel I.D.
N OTJ C E CIF COM M V NC Fryl F NY
THE UNDERSIGNEI) hereby gives Notice that improvernents will be ma de to certain real
(aropci-ty, and in accordance with Section 713.13, Florida Statutes, file following information is provided
with this Notice of Coniniencement, 'Mis notice shall k- void and of tit) forceind cfTect if construction is
not cornmenced within ninety (QO) (lays after recordation.
L Description of the Real Property: 6419-6429 Simons Road, Zephy'rhills, Fl, 33541, more
particularily described on l-'xhibit A,
2. General Description of the Improvement: construct a new 33,000 +/- SF apartment building with
site preparation and itistallation of functionally related facilities, equipment and parking, t(gethcr
Nvith varions amenities and related irriprovenients, constructed or to be constructed in connectiou
therv%kilh, upon the Real Property,
3. Name of the Owner-, SVI3 liousing, LLC., as Florida limited liability company.
Owner's Address: 23 10 W, Bristol Ave., Tampa. U1, 33609
Owner's intercst in the site of the improvement: Fec Sirriplc.
4, Name of Fee Simple Title Holder (if other than Owner)- N/A
Address: N/A
5. Name of Contruefor : Park & I'leazer Construction, 1-1-k'
Contractor's Address: 2363 Gulf to Bay Blvd., Suite 200, Clearwater, Ft., 33465
6, Name of the surety on the payment bond under Section 713.23, Florida Statutes:
None
Surety's Address: NA
Amount of tire Bond:
A copy of the Payment Bond (if any) is attached hereto (if applicable).
7, Lender (persons or entities making a loan for construction of the improvements):
REPUBLIC BANK & TRUIST(.70MPANY
1300 N. Westshore Blvd.. Suite 150
Tainpa, Fl, 33607
Tel, (813) 720-4190
Attention: Casey Roth
8. Name and address of the person within the State of Florida designated by Owner as
the person upon whom notices or other documents may be served as provided by
Section 713.13(t)(a)(7):
Name- Todd S. Lovinn er
Adelm-,vc 2310 W. Bristol Ave.,Tampa, 14, 3360(4
9. The Owner has designated the following persons, in addition it) Owner, to receive a
copy (if the Tien is notice as provided by Section 713.13(l)(b), Florida Statutes:
REPUBLIC BANK & TRUST COMPANY
661 S. Hurstbourne Pkwy, "floor
ATTN: Liz Radford
Louisville, KY 40207
(502) 561-7192 - Construction Loan Administration
10. Ex to ration Date of the Notice of Comniencvnient (the expiration date is one (I) year frorn the date
of w-cording unless a differeni date is specilted): 2021'----�
WUNINGTOOWNER: ANV:4YIft'iVTVAI,-IDERYTHf-'Olf,'iVFRAFTFRTHf,EXPI'It TIOAI
OF THE NOTICE OF COAMIENCENIENTARE COMVIDERED IMPROPER PA YMENTS IINDER
('11APTER 713, PART 1, SECTION 713.13, FLORIDA SIATUFTES, A,?VD CAN RESULTIN YOUR
PAYING TIVICE' FOR L41PROVEMLNIS TO YOUR PROPERTY A NOM,"I' OF
COMMENCEMENT I"T" BE RECORDED A" POSTED ON TUE JOB SITE BEFORE THE
"RSTINSPECTION, IF YOU LNTEND TO ORT4IN FINANCING, CONSULT WITH YOUR
LEAWER OR ANA TTORIVEY BEFORE COMAILAXING WORK 01? RL'CORDIINIG YOUR NOTICE
OF COALIVENCEIVEIVT
(SEE NEXT PAGE FOR SIGNATURE BLOCK AND ACKNOWLEDGMENT)
N
SVB HOUSING, LLC'.,
A Florida limited liability company
i
.n
Name: Todd S. f,ovin er
As its: Manager
S'i`ATE, OF FLORIDA
COUNTY OF HILLBOFtCiUGH
THE I'OREGOIlslt;i INSTRUMENT was acknowledged before me by means of : physical
presence or 0 canline: notarizaation dais m .�' . 0aay of February, 2022, by `Ladd S. Lovinger, in his capacity
as as cfcal} appointed and aantFacarireal 1uf<aaaaa er of SVB Housing, . LC, as Florida limited liability company,
n e haalf of stacla company. ` hell le either 1plcwse check (L� u pplac able) C is personally known to me or
presented a valid Florida driver's license as identification.
(11hf.t`,IV I'Adtlrtl, St-'A1.
X M S, t.2ia?2
9, .
r
NOTARY RY I'(. BLIC' [Signature Above]
Print Name: Thomas K. Morrison
Striate- of Florida
My ('011anaissicaaa
Verification
(Pursuant to Section 92-525. Florida Statutes)
hider penalties of perjury, I c ee laare. that I have read the foregoing arid that the facts stated in it
are true to the. hest ol'aaay knowledge and belief.
aaaae I`odd S Loving
SIGNATURF I AGv, FOR Ni)'1'tcv,� 01, Ct3?VlMUMI AIF \NT
EXHIBIT"A""
The Real Property Collateral is comprised of Parcel A and flareel 13, described as fioljowsl-
AH, THA'r TRACT OR PARCEL OFLAND LYIN(j IN SE"CTION 04,TOWNSHIP 26 SOUTH, RANGE 21
EAST, PASCO COUNTY, FLORIDA, BEING A POR HON 01" LANDS IN'SCRI BUD IN OF RECORDS
BOOK 7896, PACE 1672 01" FIJI: PUBLIC RFCORDS OF PASC() ('01 INTY, FlA.MODA, AND IIFIN(j MORI",
PARTICULARLY DESCRIBED AS FOLLOWS:
COMIMENCU ATTI IL NORTI IFAS FCORNFIR OF SECTION 04,TOWNSIIIP 26 SOUTIL RAW.A21 ("AS F
PASCO COUNTY, FLORIDA, SAID POINT MANG A FOUND 4"X4" CONCRETE MONUMENT WITI I DISK
STAMPE,13 "PASCO CO. Stl-.C, COV': HIENCI," SOUTH 01'55'09" WEISTALON01 [IF UASTLINE OFTHE
NORTHEAST 1,14 01" SAID SF CTION 04, A DISTANCEOF 2623,15 FUTTO`THE FAST 1/4 CORNER OF
SAID SEC'I ION 04, SAID POIN'r 141"'ING A FOUND 5/8" IRON ROD, NO IDE'NTIFICATION; THENCF:
SOUTH 8905619" WUSTALONGTJ It", SOU I'll LINE, OFT) IUNORTHEASTi/4 OF SAID ".CTON St- ' 'CTION 04, A
DISTANCL OF 1333.53 FFF I'TOTHEPOINTOF INTRS! EIOF SASOU ID FII LINE AND F"AST
LINE OF LANDS DFIS CR I B I"11) IN OFF'ICIIAL RECORDS BOOK 7890, PAGE 1672 OFTHE PUBLIC
RECORDS OF PASCO COUNTY. 02"07'06" WVS FALONG SAID LASSTLINE,
A
DISTANCE OF 347.471 FEET` TOTI EL: POIN CONTINUL SOUTI1 02*07'06"
WESTALON6 SAID A DISTANCE OF 313,49 f,Fl-T'1'0'1'111,'SOtJl'[iEAs,r CORNF'R OF SAID
LANDS; TFIFNCE SOUTH 90'00'00" WL'Sl ALONGTHE SOU11 LINU OF SAID LANDS, A DISTANCE 01:
700,00 FEET` 'roaw, sou'virwEs'j, c,(JRNI1-1'R OF SAID I,ANDS;TIII*.NCFNORTIf 02*07'06" FAST ALON6
THE WEST LINEOFSAID LANDS, A DISTANC1`01"549,84 1-4-1-1,:1-1-0 A I10INT-,THENCF, NOR"I'l I
90000'00" EASTALON6 A LINF230 FEETSOUT11 OF AND PARALLFL,roFnE NORTII DINE; OFSAID
LANDS, A DISTANCE CIF' 261,17 I"I"I'I'VO A 02'07'06" WFST A1,0NO A FINI'
200,99 FLE"YEASTOF AN DPARALLE'LTOSAID WFSFIANE', A DISTANCLI'01`17998 FFIETTO A
POINT.- TFIENCE SOUTH 89'58'29" FAST, A DISTANCEOF 179.57 FF'FITTO A POINTTIIEN("J`. SOUTH
02'07'06" WEST ALONG A LINFI 440.44 FFF"I'FIASTOl"ANT) PARALLF.LTO SAID WES'l LINE, A
DISTANCE OF 49,27 FUL'I'VO A POINT,111FINCE sount 88'26'52" FAST, A DISTANC!", OF 259. I0
FUUT YO VI IF' POINT oi, BEXANNINC,,
CONTAINING 6.703 ACRES, MORF, OR LESS,
ThisSikice hwenlionvlTv 1,c,!,fi Bluek
Legal Nscription ql'Parcel 13 is on the Fofiowin',,, Page
Fr) IIIIArr"A"
ALI,, THAT 'TRAC' OR PARCEL 01' LAND LYIN(; IN SECTION 04, FOWNSHIP 26 SOUTIE RANGE , 21
EAST. PASCC O OUNTY, FLORIDA, 1311"INFJ A PORTION OF LANDS DESCRIBFD IN OFFICIAL Rl"'CORDS
BOOK 7896, I'MIL' 1672 01"ll 11"1'UBLIC RECORDS 01" PASCO COUNTY, FLORIDA, AND BEING MORE,
PARTICULARLY DESCRIBED AS FOLLOWS°
COMMENCt,'ATTHE NOR TIJFASFCORNER OF SECTION 04, T0\V`NSJIIP 26 SOUTIL RANOE' 21 FAST'„
PASCO COU'NTY, FLORIDA, SA ID POINTBEING A FOUND 4"X4" CONCRETE M0NLPMF.,'N1.WITJI DISK
STAMPED "PASCO CO. SEC, COR,",TJ It,"NCESOUTH 01055'09" M",.S"FALONG THE EAST LINF, OFTHF,
NORTHEAST 1,4 OF SAID SECTION 04, A DISTANCE OF 262115 FEEFTO THE EAST LA CORNFIR 01;
SAID SECTION 04, SAID POINT BEING A FOUND 51" IRON ROD, NO IDENTIFICATIM, THEINCE'
sot-FITI 89'56'18" WESTALONGTIR',, SOIFFII LINE OF` THEN0RT1JF,WSJ 1/4 OF SAID SECTION 04, A
DISTANCE OF 1333,53 FEET TOTHE POIN'FOFINTERSECTION 01" SAID soum LINE AND TI IF LASJ
1ANE OF LANDS DESCRIBED IN OFFICIAL RECORDS BOOK 7896, PAGE 1672 OF THE PUBLIC
RECORDS OF PASCO COUNTY, FLORIDA, SAID POINT ALSO BEING THE POINT CAI` BFGINNIN(,J;
TI-IFNCE SOUTH 02'07'06" WEST ALONG SAID EAST LINE, A DISTANCt", OF3,47,47 FEETTO A POINT,
`rill"NCE NORTH 88026'52" WF'1S L A DISTANCE OF259. 10 1"FETTO A POIN 1'.111ENCE NORITt
0207'06` EASTALONG A LINE 440,44 FF`F1TEAST 0F' AND l�'ARAt,t,[,"L'1'0'1'111,.WESI'[,,INF OF SAID
LANDS. A DISTANCE OF 229,33 FLJ,,'TTO A POIN'l`,THENCF SOUTH 90'00'00" WEST ALONG A LINE'
230 FEETSOUTH OF AND PARALLE'LTO THE NORTH LINE' OF SAID LANDS, A DISTANCI.-l' OF 131.54
FF"ET VOA PC)INT; THENCE, NORTH 02'07'06" LAST ALONG A FINE 309 FEET EAST OF AND
PARALLEL TO SAID WESTLINE, A DISTANCEOF230.10 FSET' TOA POINT ON11111-1. NOR III LINt"'OF
SAID LANDS, THENCE NORTH 90'00'00" EAST ALONG SAID NORTII LINE, A DlS'FANCE 01: 390M
FT , ETTOTIIE' NORTHEASTCORNEROF SAID LANDS, TE1I,',NCF SOUTIl 02'07'06" WEST ALONG TI11"
1: THEIGINT FB NN N(
,ASTLINF OF SAID LANDS, A DISTANCE 01, 119,04 FELTI-0 1 0 EGI 1 3.
CONTAINING3,448 ACRFS,N,,IORI-- OR LESS,
Parcel A and Parcel
ALL HIA 1_TRAC'FOR PARCE11, OF LAND LYING IN SECTION 04, TOWNSHIP 26 S01-1111, RAN6E 21
L'AST, PASCO COUNTY, FLORIDA, BEING A PORTION OF LANDS DESCRIBED IN OFFICIA1, mXORDS
BOOK 7846, I'MIE 1672 OFTIIF� PUBLIC RFICORDS OlPASCOCOUNTY, FLORIDA, AND BLlN6, MORt"
PAR FICt,11,ARLY DESCRIBED AS 1`01 J,OWS:
(_'OMMI-`NCF'AIFIIF NORTHEASTCORNI"R OF SFCJION o4,,roWNSIJIP 26 SOUTIL RANGI,"21 FAS F,
PASCO COUNTY, FLORIDA, SAID P()INTBEING A FOUND 4"M" CONCRETI, MONUMENT Wl I'll DISK
STANIPED "I"ASCO CO, SFCCOR."THENCE SOUTH 01*55'09" WFISTALONO Il IFEASTI-INLOF THL,
NORT1111"'AST114 01: SAID SECTION 04, A DISTANCE" OF 2623,15 FEE TTO 1111" EAST IA CORNER Ot','
SAID SECTION 04, SAID POINT BEING A FOUND 5/8"IRON ROD, NCB IDENTIFJCATION; IF ILNCL,
SOUTH 89'56'18" WLSTALON0 I'M'. SOT11 LINE, OFTFIF NORTHEAST 114 OFSAID SECTION (fl, A
DISTANCE OF 1333.53 OF SAID SOLI'll LINE AND THE FAST
LINE 01"LANDS DESCRIBED IN OFFICIAL RECORDS BOOK 7896, MOE" 1072 OF THE PUBLIC
RECORDS OFPASC0 COUNTY, FLORIDASAID
SOUTH 02007'06" WESTALON(i SAID EAST LINE, A DISTANCE OF 660.% FEET 1-0 T14E SOUTHEAST
CORNER OF SAID LANDS.' THENCE SOUTH ()0'00'00" WEST ALONG THE SOUTH LINE OF SAID
LANDS, A DISTANCE OF 700,00 FEIFT TO THE SOUTHWEST CORNER OF SAID LANOS; '11111"'NCL
NORTH 02*07'06" EAST ALONGTHIi. WLI'Sl- LINE' OFSA I D I -ANDS, A DISTANCE OF549A4 1,1`11`1' R) A
POIN"Y:THENCE NORTH 90'00'00" FASTALON(j A LINE 230 s(:)t7-ri-i OF AND PARALLEJ, TO
NOKTH LINF OF SAID LAND,,*, A DISTAW , 'I," OF261,17 FEETTO A POINT; THENCE SOUTH 02'07'00"
WEST ALONG A LINE', 260,99 I`FLTF'AST OF AND PARALLELTO THE WEST LINE OF SAID LANDS, A
DISTANCE'OF 179M FEETTO A 89'58'29" EAST, A DISTANCE OF 179.57
FELTTO A POIN'r;THENCE' NORTI 102*07'06" EAST ALONG A LINE 440.44 FEETEAST OF AND
PAR ALLELTOT) It," WFST LINE OF SAID 1.,ANDS, A DISTANCE 01" 180,06 A POINT,'I'l ILNCL
SOUTH 90000'00" WFST ALONG A LINE' 230 FEET SOUTH OF AND PARALLELTOTHE NORTH LINE OF
SAID LANDS, A DISTANCI.-'01`131.54 FEF"TTO A POINTTUNCE NORTH 02"07'06" EAST ALONG A
LINE 309 f-tlJl,'I'I:'AS'l'OF AND PARALLEL TO SAID WESTLINE, A DISTANCE, 01: 230,16 FLETTO A
POINT' C)N THE NORTH LINEOI: SAID LANl)S;TIIFNCF NORTH 90*00'00" F'ASTALONCY SAID NORTH
LINE, A DISTANCL' 01, 390,80 FEF' r'I'O'FHE NOR THEASTCORNER OF SAID LANDS,' THENCE SOUTH
02'07'06" WF'IST ALONG SAID FASTUNI", A DIS'J'AN(J", 01"119.04 FEETTOTHE POINTOF
BEGINNIN(J.
CONTAINING 10. 152 ACRI"IS, 1\4ORFOR LESS
n
r ALARM
Ar1r
7-QUIPMENT SUBMITTAL
Apartment Building
11►Simons d
4020 Cayuga
Tampa, FL ► 4
0
PART#
MANUFACTURERG
I TI
AFC-100
Potter
Addressable FACP
UD-2000
Potter
Digital Alarm Communicator
RA-650OF
Potter
Remote Annunciator
PSN-1000E
Potter
NAC Power Expander
PAD100-PSDA
Potter
Addressable Pull Station
PAD100-PD
Potter
Addressable Smoke Detector
PAD100-HD
Potter
Addressable Heat Detector
PAD100-6B
Potter
Addressable Detector Base
PAD-SIM
Potter
Addressable Monitor Module
PAD100-DIM
Potter
Addressable Dual Monitor Module
PAD100-RM
Potter
Addressable Relay Module
HS-24WR-WP
Potter
WP Wall Mounted Horn Strobe
HS-24
Potter
Wall Mounted Horn Strobe
S-24
Potter
Wall Mounted Strobe
LFHS
Potter
Wall Mounted Low Frequency Horn Strobe
LFH-24W
Potter
Wall Mounted Low Frequency Horn
DTK-2MHLP
Ditek
SLC & NAC Surge Protector
DTK-120HWLOK
Ditek
120v Surge Protector
100 addresses available on this analog addressable system
Additional system capacity achieved via multi -point SLC modules
99 software zones
NTPA 72 Compliant Smoke Sensitivity Test Built -In
System Operates as Class A or Class B for SIX, P-Link and NACs
® 5 Amp Power Supply, Expandable to 310 amps
= 2 NACS;, Regulated, Rated at 3 Amps each, expandable to 188
2lnput/Output (I/0) Circuits for system flexibility rated at 1 Amp
each
Strobe Synchronization and System Wide Sync for Gentext.
AMSECOS, Cooper Wheelocktk and System Sensort strobes
Dedicated Alarm, Supervisory and Trouble Relays
4,000 Event history Buffer
Optional two tine DACT with tJD-2000 that can report General,
Zone or Point Information
Built in IP Communicator
Ethernet Port for Programming and Network Connectivity
E-Mail System Status, Reports and Event information
Product includes 5 year warranty
PTr
The AFC-100 is an analog/addressable fire alarm system with a total
system capacity, of 100 addresses, Additional capacity on the system is
achieved using multi -point SLC modules. The control panel utilizes the
exclusive Potter protocol that includes a complete line of sensors and
modules, Each SLC may be comprised of any combination of smoke
sensor, heat detectors or modules and allows for a total of 50 ohms of
impedance and may use any wire compliant with the National Electrical
Code (NEC).
The AFC-100 has a 5 Amp power supply with two Notification
Appliance Circuits (NACs) and two Inpu /Output (1/0) circuits. The
NACs are rated at 3 Amps each and the I/Os are rated at 1 Amp each.
Each output is regulated and power limited. In addition, each output is
uniquely programmable and may be configured for steady signal, strobe
synchronization, constant power,_ door holder power, or releasing. The
strobe synchronization includes Crcntex, AMSEC01, System Sensor and
Cooper/Wheelock and with the exclusive Quadrasync each output may
have a unique brand and all strobes will flash together.
The NACs inky be expanded using the PSN-1000 series intelligent power
supplies. Each P SN-1000 adds another 10 Amps of power, 2 additional
input circuits and the AFC-100 will support up to 31 power supplies. The
system will synchronise the strobes system wide. In addition, the PSN-
1000E has space to allowthe installation of up to six loop expansion cards.
The cards mount on a stacker bracket that allows access to all SLC circuit
connections.
r
NYC; Fire Dept. �
FM > Certificate Approval
of
6256. _ji
LISTED
APPROVED 7165-0328:0509
S735
IgI
16"W x 17"11 x 3 7/s"D
3.0 Amps i; 120 VAC 50/60 HZ
2.0 Amps t 240 VAC 50/601
16 gauge cold rolled steel with removable
locked door with Lexan view-inz window
Standby Current- 130 rnA
Alarm Current-200 mA
5 Amps power for NACs, 1/0, and P-I.ink
3 Amps per NAC, regulated
I Amp per 1/0 circuit, regulated
m Battery Charger range 8-55 Ah
= Battery Charger voltage 27.3 VDC
® P-Link maximum current of I Amp
32' to 120' (0°C to 49°C) with a maximurn
humidity of 93%non-condensing.
Potter Electric Signal Company, LLC St. Louis, MO = Phone: 800-325-3936 www.pottersignal.com
8830134 - REV E • 9/19
PAGE I OF 4
(E)POTTER
The Symbol of Protection Fire ,Alarm Control panel
SLC Loop Accessories
The control Panel may be connected with up to 100 addressable devices or modules in any combination. The SLC is not restricted by any special wire
requirements and may be wired with army wire that complies with the NEC.
C Loop Devices
Device Descriptions
PADI00-PD, Analog Photo Electric Smoke Detector is a smoke detector with a listed obscuration of 1.02 to 3.93 percent per foot.
PAD] 00 PHD Combination Analog Photo Electric Smoked leaf Detector -- a smoke detector with a listed obscuration of 1.02 to 3,83 percent
obscuration and a fixed temperature 135' Fahrenheit heat detector.
PAD100_HI) Analog Fixed (135d-185dF) or Rate -of Rise heat Detector (software selectable)
PAD100-l)I C T'R Addressable Duct Smoke Detector with Form C Relay. Addressable Duct Smoke Detector with Form C relay rated at l 0a (a.
250/120VAC or 8amps at 30VDC.
PAD100-DUCT Addressable Duct Smoke Detector.
PADI00-6I 6" round base that is mounted to an electrical box and wired for connection of one of the above sensors.
PAD100-4133 4" round base that may be mounted to an electrical box and wired for connection to the above sensors.
—... — - ...... -._..
PADIO� Isolator base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop.
PAD 100-RB i Addressable Relay Base that contains one relay controlled by the SLC. Relay is rated at rated at 2 amps at 30 VDC or 0.5A at 125VAC. i
PAD100-SB Addressable Sounder Base that contains an addressable sounder module that may be configured for local, group and all call.
PADI00-CD 1 Addressable CO gas detector.
------------------------------- ------ - -------- -----------
PAD] 00-DD Addressable photo electric smoke detector for use in DUCT iDUCTR enclosure.
PAI)100-L1a""SIT Addressable Low Frequency Sounder Base that contains an addressable sounder .module that may be configured for local, group and all
call. The LFSB complies with the Low Frequency Signal Requirements (520 Hz)
PADI00-SPKB Speaker base is a wall or ceiling mount speaker capable of25 or 70.7 VRMS and is field selectable From 118ik%to 4W
Modules
_� _. ... ... _ .
�� DcrMp'tEon
PAD100-MINI 1 Micro Input Module provides a small foot priest contact module for mounting; inside an enclosure. j
PADltlO l'SSA Single Action Addressable Pull Station.
PAD100-PSDA ; Dual Action Addressable Pull Station.
Single Input Module is a standard contact module with an LED that mounts into a 4" square electrical box.
�PAD100-DIM Dual Input Module is a device that can monitor two distinct inputs with a single device or in a Class A mode.
PAD100-TRTI Two Relay Two Input module provides two form C, relays that are individually controlled by the control panel Each relay is rated for 2
amps at 30VDC, or 0.5 amps at 125NIAC. Also provides two contact inputs.
PAD100-NAC I Notification Appliance Circuit module is an addressable remote appliance circuit controlled by the panel.
PAD100-7M Zone Module is used to connect conventional 2-wire smoke detectors to the system. - -- -- -- -
I'Ai100-IM Isolator Module mterruptvs a short on the SI.0 and prevents the short from -affecting protected devices on the loop._ - - - -}
PADI00-R Yt flay Module that provides one form Crc lay controlled by the control panel. Relay- is rated for 2 amps at 30VDC` fir 0.5 amps at 125VAC.
_........... -- -_--
PADl00 t.ED Module provides a single addressable LED that is controlled by the control panel
PAD100 SM Speaker Module provides switching for two audio channels.
PA6100-LEDK 1 Addressable LED and key switch that mounts in a single gang box.
PAD 100-DRTS DtJCTR Remote test Switch that mounts in a single gang box and optionally supervised, For use with the PAD 100-DUCTR only.
PADl00-ORCtI One Relay One Input Module provides one form C relay and one input, the relay is rated at 2 amps at 30VDC or 0.5 amps at 125VAC. ...._
Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersigiial.com
8830134 - REV E a 9119 R GE 2 OF 4
(E)POTTER AFC-1 00
The Symbol of Protection Fire Alarm Control Panel
SLC Features
The Potter protocol is a digital protocol with a proven design for
reliability and noise immunity. The system does not require special
cable or conductors for connection of the Signaling Line Circuit
as long as the cable is compliant with NFPA 70and NFPA 72.
The system allows for Class A or Class B installations as well as
"T-Taps", with a toss wiring distance of 107000 Ft.
The sensors through the fire alarin control panel provide a real
time status as to the condition of the system. The smoke detector
sensitivity, beat detector temperature level and drift compensation
are all programmable options. The system also allows for a day/night
mode where the panel automatically adjusts the sensitivity depending
on the time of day. To assist in the reduction of alse alarms, the
smoke detectors also have a maintenance warning that sends a trouble
signal when a detector is dirty to the point that it can no longer
maintain the programmed sensitivity.
User Interface
The fire alarm control panel has a 2 x 16 LC `D display to provide
information to the system status. The keypad has navigation keys
to allow manipulation of the Menu on board the panel. The panel is
shipped standard with the following LEDs:
AC Power - Green
Alarm - Red
Earth Fault - Amber
Supervisory - Amber
Silenced - Amber
Trouble - Amber
Pre -Release -Amber
Release - Red
The common buttons include a Silence, Reset, Acknowledge,, and
Drill. All of the buttons are accessible once the locked door is
opened.
P-Link
The AFC -I 00 has a proprietary communication protocol that
communicates through a RS-485 connection to field devices. Up
to 32 devices may be connected to a single P-Link connection. The
P-Link includes the communication terminals and regulated 24 VDC
connection for the field devices. The field devices may be any of the
following:
SLCE-127 -Nohmi addressable loop expansion module for retrofit
applications.
RA-6500R(F) — 4 x. 40 LCD annunciator with a key pad in a locked
metal enclosure. Flush mount Version available.
LED-16(F) — 16 LED annunciator with common indicators in a
locked metal enclosure. Flush mount version available.
PSN-1000(E) — 10 amp, remote intelligent power supply with
6 NACs, 2 Inputs and a P-Link repeater. This panel is listed in
conjunction with the AFC-100 as releasing circuits,
CA-6075 — Class A convertor that converts the SLC, NACs and
P-Link connection
UD-2000 — UL listed, Dual line telephone alarm communicator
DRNI-50 — LED driver expander, used to connect up to 50 LEDs in a
graphic display
FCB-1000 — Fire communication bridge, provides remote mounting
of the Ethernet connection
FIB-1000 — Fiber interface module, used to extend P-Link to multi -
mode fiber (2 required)
RLY-5 — Relay module, provides 5 form C relay contacts rated at 3.0
amps 24VDC/ I 25AC
SPG-1000 — Serial parallel gateway, allows for the connection to a
serial or parallel printer
The FIB-1000, FCB-1000 and the SPG-1000 may be installed in the
stacker bracket or ordered with the optional rack mount enclosure.
MC-1000 Multi -Connect allows tip to sixty-three AFC series panels
to share a single reporting technology.
JDC-6 — Initiating device circuit provides 6 programmable inputs
AE-2 —Two card expansion cabinet
AE-8 — Eight card expansion cabinet
The AFC- 100 is shipped standard with an E..themet connection.
This connection is the programming port and may be connected
to a building Wide Area Network (WAN) or Local Area Network
IJAN), Once connected to the Internet, the panel may be selectively
programmed to e-mail alarm conditions, trouble conditions,
supervisory conditions, test, Event History and detector status. An
e-mail may be sent to the panel and the panel will e-mail the event
history, detector status, configuration file or server status to an
authorized E-mail account. In addition, reminders may be set to send
an e-mail for service, testing or other conditions.
In addition, the Ethernet connection is UL listed as an IP
communicator. The IP communicator is listed to report to the 1.111,
listed Sur -Gard III IP receiverAhe IP con-imunicator replaces the
traditional less reliable alarm communicator transmitter that utilized
telephone lines. The IP communicator is an active method of
connection and communication to the monitoring station.
Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 w www.pottersigiial.com
8830134 - REV E - 9119 PAGE 3 OF 4
LEFT SIDE
0 o
TOP DEPTH = 3.75 "
0 0
i
DOOR = 16.07"
BACKBOX = 15.77" DEPTH = 3.84"
BOTTOM
Ordering Information
DescriptionWj���,pla�,rn,m Board �Al, 0
um
i
N E)
RIGHT SIDE
MG N193 1
Potter Electric Signal Company, LLC " St. Louis, MO Phone: 800-325-3936 0 www.pottersignal.com
8830134 - REV E e 9/ 19 PAGE 4 OF 4
(E)POTTER UD-2000
The Symbol of Protection Digital Alarm Communicator
Features
Allows for communication to Monitoring Station
m Communicates using SIA-DCS or Ademco Contact ID Protocols
For use with IPA, AFC, and ARC series Addressable Panels and
PFC-4064 Conventional Panel
Status LEDs indicate operation of DACT card
Installs with ease behind main panel LCD display via User
Interface bracket
• Device address is set internally to address 1
Includes two (2) RJ45 phone cords
<`FLISTED
.
Technicali ti
The UD-2000 Digital Alarm Communicator Transmitter (DACT)
provides for up to two (2) phone fines for communication to a
monitoring station. The UD-2000 communicates using the SIA-
DCS or Ademco Contact ID protocols. When enabled, the DACT
automatically monitors each phone line or voltage and has the
ability to seize the line and connect with a remote receiver. Once the
communication is complete, the DACT will hang up.
The DACT is provided with terminal blocks for each phone line and
two RJ45 cords. In order for the DACT to work properly, it must be
installed on a plain old telephone service (POTS) line or equivalent
deemed by the authority having jurisdiction. The DACT must be
installed before any other equipment to ensure it can seize the phone
line.
Phone lines are high voltage and should be run in a separate conduit
from other circuits. The wire conductors connecting the DACT to the
phone system should be 26 AWG or larger.
Potter Electric Signal Company, LLC s St. Louis, MO • Tech Support: 866-956-1211 l Customer Service: 866-572-3005 - www,pottersigual.com
8830146 - REV B ® 6119 PAGE 1 OF 3
(E)POTTER
The Symbol of Protec
J31 X Phone Jack to Z..,TD-2000
Plain Old Telephone (POTS) lines
Tip (Brown) Ring (Grey)
Out to Premises Phones
Line In From Telco
a
Out to Premises Phones
Line In From Telco
Installation
The UD-2000 DACT is connected to the control panel using the provided four -wire cable connection (P1N 5210514) between P4 and UD-2000 PI.The
connection is power limited and supervised.
1. Power system down.
1 Slide the LTD-2000 into the card guides located under the User interface bracket.
3, Secure the UD-2000 to the User Interface bracket using the provided #6-32x3/8" screw
4. Install the provided four -wire conductor jumper between UD-2000 PI and P4.
Potter Electric Signal Company, LLC . St, Louis, MO - Tech Support: 866-956-1211 / Customer Service: 866-572-3005 a www.pottersignal.com
8830146 - REV B a 6/19 PAGE 2 OF 3
1.
lit
Slides in guides under main board(1 4 o v.. DWG#593-32A
P Connector on
small platform
control panel
1�
a a
connector
main board
Ordering Information
Model (Description Stock No.
UD-2000 Digital Alarm Communicator 3992769
Potter Electric Signal Company, LLC ° St. Louis, N10 m Tech Support: 866-956-1211 l Customer Service: 866-572-3005 - www.pottersignal.com
8830146 - REV B m 6119 PAGE 3 OF 3
(E)POTTER
The Symbol of Protection
• industry leading 4 line by 40 Character LCD
• Common buttons for navigation
• Common LEDs ,for status indication
• 31 annunciator per panel
• Maximum wire length of 6,500 feet
• Available in 4 colors
• Product includes a 5 year warranty
• UUKL Listed f'or Smoke Control
<S>
_k
x"
&
APPROVED
�.v�
LISTS
escription Technical Specifications
The RA-650OF is a flush mount LCD remote annunciator for various
Potter fire control panels. The RA-650OF communicates using a RS-
485 connection to the main panel providing common indication of
Alarms, Supervisory, Trouble and other system status and control.
functions.
The RA-650OF features a 4x40 LCD display with L ED's for Power,
Alarm, Supervisory, Trouble, Silence, Pre -Release, and Release
conditions. It can be flush mounted or surface mounted. The
annunciator is enclosed in a sheet metal enclosure and has a Potter
lock securing the key -pad.
Potter Electric Signal Company, LLC • St. Louis, MO Phone: 800-325-3936 www,pottersignal.com
8830094 - REV D • 1/21 PAGE I OF 4
Installation
`The RA-650OF is connected to the PFC series or IPA series fire control panels using a four wire RS-485 connection, The connection is power limited
and supervised. Up to thirty-one (3 1) RA-650OF LCD annunciators can be connected using Class B or Class A wiring. Class A wiring requires an
optional Class A Expander.
RA - 6.50OF Class B Wiring Example
Fig I
To the next device
RA-6504F Front New
Fig 3
Potter Electric Signal Company, LLC
RA-6500F Class A Wiring Example
Fig 2
St. Louis, MO • Phone: 800-325-3936
• www.pottersignal.com
8830094 - REV D • 1/21 PAGE 2 OF 4
i 2 }
w
( I
2.37 5.00
PLCS 2 PLCS
f
9
.65
4 PLCS
Potter Electric Signal Company, LLC St. Lotus, MO Phone: 800-325-3936 a www.pottersigiial.com
8830094-REV D a l/21 1'A€3E 3 OF 4
(E,)POTTER RA-650OF
The Symbol of Protection LCI3Annunciator F"lush Mount
Dip SwitchSettings
Refer to the table
below for
dip switch
settings per Annunciator
Address.
Annunciator
Dip Switch Settings
Address
SNV-1
SW-2
SW-3
SW-4
SW-5
1
On
Off
OF
oir
OF
2
Off'
On
Off'
Off'
Off
3
On
On
Off
Off
Ott
4
Oft
Off
On
tiff
Off
5
On
Off
On
Off"
Off
6
Ofi
On
On
Oil
Off'
7
Oil
On
Oil
Off
Off
S
Off
Off
Off
On
Off`
9
0n
Oft
Off
On
Off
10
Ofr
On
Off'
On
Off'
11
On
Oil
Off
On
Off.
12
Off
Off
On
On
Off
13
On
Oft'
On
On
off
14
Oft
0,
On
On.
Off
15
On
On
Orl
On
Off'
16
Off
I Off
Off
Off
On
TWodei
Description
Stock No.
RA-65001,
LCD Annunciator Flush Mount'- RED
3992725
RA-6500F
LCD Annunciator Flush Mount - BLACK
3992741
RA-6500F
LCD Annunciator Flush Mount - GRAY
3992742
RA-6500F
LCCAnnunciatorFlushM®U27t-L1CsHTG1Y
3992743
Annunciator
Dip Switch Settings
Address
SW -1
SW-2
73
SW
SW-4
SW-5
17
On
Off
Off
Oft'
On
18
Off'
Or
Off
Off
On
19
On
On
Off
Off
On
20
Off
Off
On
Off
Oaz
21
On
Off
On
Off
Oil
22
Oft
0,
On
Off'
On
23
On
On
On
Off
Oil
24
Off
Off
Off
On
On
25
On
Off
Off
On
On
26
Off
On
Off'
On
On
27
On
On
Off'
On
On
28
Off
Off'
On
On
On
29
On
Off
On
On
On
30
Off
On
On
0n
On
31
On
On
On
On
On
Potter Electric Signal Company, LL.0 St. Louis, MO Phone: 800-325-3936 a www.pottersignal.com
8830094- REV D > 1/21 PAGE 4 OF 4
(E)POTTER PSN-1 OOO(E)
The Symbol of Protection Fewer Expander
Features
® 10 Amp Power Supply
• 3 Amps, regulated per NAC.
• 6 NACs Class B or 3 NACs Class A
• 2 dry contact inputs
• Fully programmable and monitored through control panel
• Isolated P-Link repeater connection, Class A or B
• Up to 31 power supplies per control panel with system wide
sync
• Quadrasync feature synchronizes strobes from.AMSECO,
Gentex, Cooper -Wheelock and System Sensor.
The PSN-1000 series is a UL listed intelligent '10 arnp notification
power supply and P-Link (RS-485) repeater. The power supply
connects to the P-Link bars from the control panel and is operated and
supervised from the panel. The power supply may be installed 6,500
feet from the control panel. The PSN-1000 then repeats the P-Link
communication for another 6,500 feet.
The power supply has six (6) Class B or three (3) Class Apower
outputs. Each output is regulated and power limited with a 3
Amp maximum rating, In addition, the PSN-1000 has two (2)
programmable dry contact inputs. The dry contact inputs are Class B,
supervised inputs.
The power supply operates on either 120 or 220 VAC power and
has a regulated 24 VDC output. 1n addition, the panel can charge
up to 55 All batteries and will house 18 All batteries. The cabinet
is constructed out of 18 gauge cold rolled steel with a durable
red powder coat finish. A standard Potter key lock is provided for
securing the door. Electrical conduit knockouts are provided on the
sides and top providing installers with multiple options for installing
conduits and providing proper power separations.
'the PSN-1000 is a self contained intelligent power supplyfP-Link
repeater complete with cabinet. The PSN-1000E is the intelligent
power supply/P-Link repeater with additional cabinet roomfor
mounting stacker bracket modules including P.AD 100-SLOE loop
expanders. Both cabinets include space for 18 AH batteries.
FM
APPROVED
7165-0328: 0195 S2930
The power supplies are programmed and controlled through the main
control panel P-Link bus. The: panel displays any troubles or off
normal conditions of the power supply and the events are stored in
the parcel history buffer.
Each output can be independently configured to provide one of four
synchronization patterns, Amsecolb, Center, Cooper WheelockV
and System Sensor. The ouputs can be also configured for constant
power, resettable power, sounder base power, door holder power
(with or without a low AC drop out), ANSI temporal Code 3, Cite Tie
or be a releasing circuit for 24vdc solenoids.
Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.potters ignal.eom
8830032 - REV E • 04/20 PAGE I OF 2
IBM RIM ME
Model Description Stock No.
PSN-1000 Power Expander Standard 3992662
Cabinet
PSN-1000(E) Power Expander Large Cabinet 3992665
Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 a www.pottersignal.com
8830032 - REV E ° 04/20 PAGE 2 OF 2
Single or Dual Action versions
Durable die-cast construction
Reset key matches the [ire alarm control panels
Compatible with IPA Series panels
a SEC Class A, Class X & Class B
Product includes a year warranty
UUKL Listed for Smoke Control
k ;y
The PAD100-PSSA (Single Action) is activated by simply pulling
the white "'C" bar handle down. The PAD100-PSDA (Dual Action)
is activated by lifting the front cover and then pulling the white "T"
bar handle down. Once activated, the "T' bar cannot be reset without
opening the front cover. Opening the front cover will also activate the
pull station. To reset the PAD 100-PS Series, use the Potter WS-93 key
to unlock and open the front cover. Once the cover is open, push the
"T" bar back into the normal position and re -secure the front cover.
The PAD 100-PSSA/PSDA is compatible with Potter's IPA and AFC/
ARC series addressable fire alarm control panels. It is a non -coded
addressable pull station available in either a single or dual action
model and installs on a',single gang box or surface mounts using the
P32-BB or P32-DBB (deep) back box.
9
FM .N,
APPROVED
Technicalfi i
Potter Electric Signal Company, LLC St. Louis, MO a Phone: 800-325-3936 www,pottersigiial.com
8830097 - REV D • 12/18 PAGE 1 OF 2
Pull Station Front Hew
Fig 1
J
III 1i�10
U L� QPo
PAD 100-PSDA
Pull Station Back View and Wiring
Fig 2
FROM FACP OR
PREVIOUS DEVICE
TO NEXT DEVICE
-D-
Ordering Information
Model Description Stock No.
PAD100-PSSA Addressable Pull Station, Single Action 3992721
PAD100-PSDA Addressable Pull Station, Dual Action' 3992720
PAD 100-PSSA
FACTORY WIRED CONTACTS
Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 m www.pottersignal.com
8830097 - REV D , 12/18 PAGE 2 OF 2
(E)POTTER, The Symbol of Protection Photoelectric .,Smoke Sensor°
I
® Low profile, less than 2 inches with the base
• 'Wide selectable sensitivity range of 1..0 to 3.7%1 Foot
Sensor communicates sensitivity to control panel
UL listed smoke calibration and sensitivity
Optional locking tab to prevent unwanted removal
g Simple DIP switch address setting, no programming tool
required
LED alarm indicator
Product includes a 5 year warranty
g I3IJKL Listed for Stroke Control
I
The Photoelectric Smoke Sensor is a listed Analog Addressable smoke
sensor compatible with fire alarm control panels that utilize the Potter
Addressable Device (.AD) protocol. The PAD 100-PD is a low profile
smoke sensor with a wide sensitivity range. The sensor and base (not
included) are made of a durable plastic in an off-white color to blend
in with the ceiling.
'lhe ITAD I00-PD has a sensitivity range of 1.0 to 17 % per foot and
is UL. The PADI00-PD features drift compensation and has built in
dirty detector warning as well as. The PADI00-PD and the control
panel cortununicate over a proven and robust digital comriumication
path and the system analyzes the information at the particular device.
The total polling speed is Less than five (5) seconds, well under the UL
requirements.
The sensor is compatible with any of the PAD series sensor bases and.
simply twists on. The PADI00-PD is addressed using DIP switches
in the rear of the sensor and can be easily programmed in the field
without special tools.
Setting Address
Each addressable device on the SLC loop must have a unique address
from 1 to 127 to function properly. The address is set using DIP
switches.
Before connecting a device to the SLC loop, take the following
precautions to prevent potential damage to SLC or device. Verify the
following:
1. Power to the device is removed
2. Field wiring is, correctly installed.
3. Field wiring has no open or short circuits.
��.M'g4
AVPHF
V
APPROVED _`:. FISTED
Technical Specifications
Potter Electric Signal Company, LLC s St. Louis, MO Phone: 800-325-3936 www.pottersignal.com
8830108 - REV D • 12/18 PAGE 1 OF 2
Y
tsh
Air Velocity Ratings
The PAD I00-PD has an Open Area of Protection air velocity rating of 0 to 300 feet per minute:
The system has a maximum of 30 LEDs that can be turned on simultaneously. If the system already has 30 LEDs on, the PAD 100-PD will operate even
though the LED may not illuminate.
�
The PAD I00-PD is an analog addressable sensor that uses one address on the Signaling Line Circuit (SLQ of a compatible fire alarm control panel.
The unit communicates with the control panel as it is polled. The LEDs flash every time the unit is polled and they will flash at a fast rate if the writ is
in an active status. The polling LED can be turned off if' desired for less conspicuous operation.
The PAD 100-PD with the PAD 100-4DB or PAD 100-6DB has a low profile of less than two (2) inches to blend into the surrounding environment. The
sensor includes an insect screen to prevent foreign objects from reaching the chamber and the can be cleaned to restore operation of a dirty detector.
The PAD I00-PD and the compatible control panel work in tandem to keep the sensitivity consistent. As the sensor is installed over time, the sensor
compensates for the dirt in the unit until it is out of range. At that time, the panel will indicate a dirty sensor. 'Fhe sensor will then have to be cleaned
or replaced.
The PAD I00-PD can be programmed to provide a maintenance alert prior to reaching the dirty sensor level which will allow for intervention prior to
the sensor going into trouble. This allows for sensor replacement or cleaning prior to a nuisance trouble occurs.
. 'OT Lr As required by NP'PA, do not install the sensors until all construction is complete and the work area has been thoroughly cleaned. If the sensors
have been installed in a construction environment, they should be cleaned or replaced before the system is placed into service.
Spacing
The PAD I00-PD is UL listed with a recommended maximum spacing of 30 feet. Refer to NFPA 72 for specific information regarding detector spacing,
placement and special applications.
Compatible Bases
All bases will mount on a single gang, double gang, octagon, 4" square or mud ring electrical box
Device
Description
Stock No.
PADI00-4DB
4" Standard Base
3992731
PAD100-61)13
6" Standard Base
3992732
PAD 100-1B
6" base with an isolator module included.
3992730
PAD I00-RB
6" base with one Form-C relay contact. 2A a 30VDC, 0.5A ,.d., 125VAC
3992728
PAD100-SB
6° base with sounder module included. Sound pattern is provided from external source.
3992729
PAD100-SPKB
6" base with speaker included
3992762
' �:
M
odel D
escription Stock No.
00-Pa moke Sensor 3992733
Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com
8830108 - REV D • 1218 PAGE 2 OF 2
(E)POTTER
The Symbol of Protection
• Selectable hate of Rise and/or Fixed 11eat Detector
• Low profile
• Reliable detection technology
• LED Alarm Indicator
• Ambient temperature listing of 32' F to 150' F
• Simple DIP switch address setting, no programming tool
required
• Product includes a 5 year warranty
• UUKL Listed for Smoke Control
r^—
FM
APPROVED _.`4-'_ 1 LISTED
Technical Specifications
The PADI00-HD is a listed Analog Addressable rate of rise and/or
fixed temperature heat sensor compatible with any fire alarm control
panel that has the Potter Addressable Device (PAD) protocol. The heat
sensing portion utilizes a proven thermistor for accurate and reliable
heat detection. The sensor and base (not included) are made of a
durable plastic in an off white to blend in with the ceiling.
The PADI00-HD is UL listed with a selectable fixed temperature
point from 135' to 1.85' Fahrenheit and can be used for rate of rise
applications. See detector spacing limitations below. This flexibility
allows the installer to cover a wide variety of applications with a single
unit.
The PADI00-I11) and the control panel communicate over a proven
and robust digital communication path and the system analyzes the
information at the particular device. The total polling speed is less than
five (5) seconds, well under the UL requirements.
The sensor is compatible with any of the PAD series sensor bases and
simply Hoists on. The R D100-E11) is addressed using DIP switches
in the rear of the sensor and can be easily programmed in the field
without special tools.
Each addressable device on the SLC loop must have a unique address
from I to 127 to function properly. The address is set using DIP
switches.
Before connecting a device to the SIX loop, take the hallowing
precautions to prevent potential damage to SIX or device. Verify the
hallowing:
1. Power to the device is removed
2. Field wiring is correctly installed.
3. Field wiring has no open or short circuits.
Potter Electric Signal Company, LLC St. Louis, MO • Phone: 800-325-3936 www.pottersignal.com
8830110 - REV E 6/20 PAGE I OF 2
(E)POTTER
The Symbol of Protection Recut Detector
,` ;r: ;t?
The PAD1O0-11D is an analog addressable sensor that uses one address on the Signaling Line Circuit (SLC) of a compatible fire alarm control panel.
The unit communicates with the control panel as it is polled. The LED flashes every time the unit is polled and will flash at a last rate if the unit is in
an active status. The polling LED can be turned off if desired for less conspicuous operation.
The PAD10O-111) with the PAD10O4DB or PAD] 00-6DB has a low profile to blend into the surrounding environment. The system has a maximum
of 30 LEDs that can be turned on simultaneously. If the system already has 30 LEDs (in, the PAD 1O0-gam} will operate even though the LED will not
illuminate.
The ANSFUL listed spacing limitations of PAD10O-HI) smooth ceiling are dependent on alarm set point.
Alarm Set -Point Rate of Rise Spacing Fixed Temperature Spacing
135°F to 160°F Max. 70 ft. Max. 70 ft.
(57°C to 71°C)
161 °F to 17411
Max.
(72°C to 79°C) 60 ft. Max. 60 ft.
1751%to 1851F ::Max.5 fi. Max�ft,
(A0°C to 85°C)
Compatible Bases
All bases will mount on a single gang, double gang, octagon, 4" square or mud ring electrical box.
Device Description Stock No.
PAD1O04DB 4" Standard rase 3992731
PADI,00-6DB'' 6" Standard Base 3992732
PAD1O04B 6" base with an isolator module included. 3992730
PAD1O0-RB 6" base with one Form-C relay contact. 2A n 30VDC, O.SA (u; 125VAC 3992724
PAD1OO-SB 6" base with sounder module included. Sound pattern is provided from external source. 1 3992729
PAD100-SPKB 6" base with speaker included 13992762
Ordering Information
so 11�
NUM0111111111111111111111 ii�
Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com
8830110 - RE V E • 6120 PAGE 2 OF 2
D B16 QB
The Symbol of (E)POTTER� rotection / 1 Detector r.
Terminals Marked with Polarity to assist with installation
Duplicate terminals for in and out SLC wiring
'Terminals accept 22 to 12 AWG wire sizes
Installs on single gang, double gang, octagon or 4" square box
Locking tab prevents unauthorized detector removal
Product includes 5 year warranty
41-161 ME
APPROVED t_. B LISTED
Il'1 � I ;.> .C• T�
The Potter PAD100-6DB and PAD100-4DB detector bases are used
to install Potters addressable smoke and heat detectors. The PAD100-
6DB will mount on a single gang, double gang, octagon or 4" square
electrical box.
The PAD100-6DI3 and PA.DI00-4DB are low -profile, surface mount
bases used with Potter's addressable detectors. The base uses screw -
clamp terminals that accept wire ranging from 22 to 14 AWG, When
installed on recessed electrical boxes the PAD 100-6DB is wide enough
to completely cover the back box and the immediate surrounding area.
The base is equipped with a locking tab to deter unauthorized removal
of the attached detector.
Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com
PRINTED IN USA 8830107 - REV C ® 12/18 PAGE I OF 2
7
s
t �
Locking eature
The PADlOO-6DB and PAD1004DB include a locking feature that
prevents removal of the detector without using a tool.
1. To eliminate this feature, break off the locking tab (refer to Figure
1), and then install the detector.
Fig. I
2. To remove the detector from the base when the locking feature has
been enabled, insert a small screw driver into the slot on the base to
push the plastic tab while simultaneously turning the detector head
counter -clockwise.
Fig, 2
Insert small serewdr
into slot to remove
detector from base.
Potter Electric Signal Company, LLC
St. Louis, MO
.t [� f � s r r t ♦'�
To FA(
Loop (
Ordering Information
Model Description Stock No.
PAD100-6DB 6" Sensor Base' 3992732
PAD100-4DB 4"Sensor Base 3992731
Phone: 800-325-3936 www.potters ignal.coin
PRINTED IN USA 8830107 - REV C: ` 12/18 PAGE 2 OF 2
® One (1) Class B monitoring input
SIX Class A, Class X & Class B
Mounts in a standard 4" or double gang box
® Wiring terminals accessible when mounted in box
® All wiring terminals accept 22 to 12 AWG
s Product includes a 5 year warranty
UUKI, Listed for Smoke Control
tlt TE. This addressable module does not support 2-wire smoke
detectors.
Technical
The PAD100-SIM uses one (1) SEC loop addresses when monitoring
one (1) Class B circuit. The module mounts on either a 4" square or
double gang box. The module is capable of monitoring one (1) Class
B circuit. The PAD100-SIM includes one red LED to indicate the
module's status. In normal condition, the LED flashes when the device
is being polled by the control panel. When the input is activated, the
LED will flash at a fast rate.
1M =
The PAD100-SIM is compatible with Potter's IPA and AFC/ARC
series addressable fire alarm control panels. The PAD100-SIM is an
interface module used to monitor dry contact devices such as sprinkler
watertlow, valve tamper switches, or conventional pull stations. The
module is capable of monitoring one Class B circuit.
Setting the Address
Each addressable SIX device must be assigned an address. The address
is set using the DIP switch located on the PAD 100-SIM.
Before connecting a device to the SLC loop, take the Following
precautions to prevent potential damage to the panel or device:
1. Power to the device is removed.
2. Field wiring is correctly installed.
3. Field wiring has no open or short circuits.
�; 7 S
FiVa`81
i
APPROVED
Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www,potters ignal.com
8830083 - REV D - 12/18 PAGE 1 OF 2
(E)POTTER PAD100-SIM
The Symbol of Protection Single Input Module
r
Wiring' r
PAD10O-SIM With Class P Circuit
Fig 2
FROM FACP
PREVIOUS A
TO NEXT M,
END -OF -LINE RESISTOR
5.1KOHM l W
Part #3005013
Ordering Information
gMod&e1jEE rDesEcription E�tnel� �'o. put Mc clule< 3992704
Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 e www.pottersignal.com
8830083 - REV D ° 12/18 PAGE 2 OF 2
(2,)POTTER PAD100-DIM
The Symbol of Protection Dal Input Module
Single module with dual contact monitoring inputs
Two (2) Class B or one (1) Class A monitoring inputs
® SLC Class A, Class X & Class B
® Mounts in a standard 4" or double gang box
Wiring terminals accessible when mounted in box
All wiring terminals accept 22 to 12 AWG
• Product includes a 5 year warranty
UUKL Listed for Smoke Control
NOTE: This addressable module does not support 2-wire smoke
detectors.
FM
i
APPROVED
Technical Specifications
The PAD100-DIM uses one (1) SLC loop address when monitoring
tvvo (2) Class B circuits or one (1) Class A circuit. The module mounts
on either a 4" square or double gang box. The module is capable
of monitoring two (2) separate class B circuits making it ideal for
monitoring sprinkler waterflow and valve tamper switches when they
are located in the same proximity. The PAD I00-DIM includes one red
LED to indicate the module's status. In normal condition, the LED
flashes when the device is being polled by the control panel. when an
input is activated, the LED will flash at a fast rate.
M. = y
The PAD100-DIM is compatible with Potter's IPA and AFC/ARC
series addressable fire alarm control panels. The PAD100-DIM is an
interlace module used to monitor dry contact devices such as sprinkler
waterflow, valve tamper switches, or conventional pull stations. The
module is capable of monitoring two separate Class B or one Class A
circuits.
gmtj�tmy
Each addressable SLC device must be assigned an address. The
address is set using the DIP switch located on the PAD 100-DIM. When
the PADI00- DIM is used to monitor two individual Class B circuits
a single device address is assigned, each input is then identified as a
sub -point of the module address. For example, if the address number
is assigned as "8", the first input will be "8.1" and the second input
will be "8.2".
Before connecting a device to the SLC loop, take the following
precautions to prevent potential damage to the panel or device:
1. Power to the device is removed.
2. Field wiring is correctly installed.
3. Field wiring has no open or short circuits.
01
Potter Electric Signal Company, LLC a St. Louis, MO Phone: 800-325-3936 www.pottersignal.com
8830082 - REV D ® 12/18 PAGE I OF 2
Miring Diagrams
Xj.1kUb1-1j-MLwAtb t
Q NOTE:
END -OF -LINE RESISTOR
15 NOT REQUIRED
P9D]00-DIM With Two Class B Circuits
Fig 3
END -OF -LINE
RESISTOR
5.1KOHMyzW
Part#3005013
END -OF -LINE
RESISTOR
5.iKOHMyW
Part #3005013
Ordering Information
Model Deserip,ti®n SI�ck No.
PAD100-DIM; Dual Input Module 3992703
MOVE THE"CL-A"DIP SWITCH
TO "UP" POSITION
FOR CLASS A WIRING
MOVE THE "CL-A" DIP SWITCH
TO "DOWN" POSITION
FOR CLASS R WIRING
Potter Electric Signal Company, LL.0 a St. Louis, MO Phone: 800-325-3936 www.pottersignal.com
8830082 - REV Q 12/18 PAGE 2 OF 2
(E)POTTER
The Symbol of Protection
One (1) Form C relay contact
SLC Class A, Class X & Class B
Mounts in a standard 4" or double gang box
® Wiring terminals accessible when mounted in box
All wiring terminals accept 22 to 12 AW t
Product includes a 5 year warranty
® UUKL Listed for Smoke Control
FM f IN
APPROVED --}
Technicalifi ti
The PAD100-RM uses one (1) SLC loop address to provide one (1)
Form C relay contact. The module mounts on either a 4" square or
double gang box. The PAD100-RM includes one red LED to indicate
the module's status, in normal condition, the LED hashes when the
device is being polled by the control panel.
Application
The PAD100-RM is compatible with Potter's IPA and AFC/ARC
series addressable fire alarm control panels. 'The PAD100-RM is an
interface module providing one (1) Form C relay contact.
Each addressable SLC device must be assigned an address. The
address is set using the DIP switch located on the P_AD100-RM. The
PAD100-RM uses a single device address to identify relay contacts.
Before connecting a device to the SLC loop, take the following
precautions to prevent potential damage to the panel or device:
I. Power to the device is removed.
2. Field wiring is correctly installed.
3. Field wiring has no open or short circuits,
Potter Electric Signal Company, LLC St. Louis, MO a Phone: 800-325-3936 www.pottersignal.com
8830084 -REV D ° 12/ 18 PAGE I OF 2
0�0
C� 0
� '
Wiring Diagram
PATH00-RMRelay Circuit
rig 2
FROM FACP OR
PREVIOUS MODULE
TO NEXT MODULE
1) FORM C
'CONTACTS
It is possible, that the internal relay in the PAD 100-RM may be shipped in the non -normal f activated state. To ensure that the internal relay is sci to the
normal state, connect the module to the SLC loop and reset the control panel before terminating the wiring to the modules output.
Ordering Information
[gPA�D�100-RM�
�RelyModule
ption Stock No,
3992705
Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com
8830084 - REV D 1 12/18
PAGE 2 OF 2
I
24VDC units have Geld selectable candela options of 15, 30, 607
75 & 110
Super -Slidell Bracket - Ease of Supervision Testing
Checkmate(k - Instant Voltage Verification
® Synchronize strobe and/or horn with AVSM Control Module
Prewire entire system, install mounting bracket, then install
signals
Documented lower installation and operating costs
Switch selection for high or low dBA
• Switch for chime, whoop, mechanical and 24001-1z tone
• Tamperproof re-entrant style grill
Switch for continuous or temporal 3 tone (not available on
whoop tone)
Silence audible while visual appliance will remain flashing (for
use in accepted jurisdictions)
® Faceplate available in red or off-white
Description
The S424/11S-24 Series is a low profile: strobe and hornl
strobe combination that offers dependable audible and visual
alarms and the absolute lowest current available. The S-24
& HS-24 Series 24VDC offers tamperproof field selectable
candela options of 15, 30, 60, 75, and L10 candela. The
Strobe and Horn/Strobe offers a continuous or sync temporal.
three in 2400Hz and mechanical tone, a chime and whoop
tone. All tones are easy .for the professional to change in the
field by the use of switches. The S-24 & IIS-24 Series has a
minimal operating current and has a minimurn flash rate of
IHz regardless of input voltage.
This Series is shipped with a standard 4" metal mounting
plate which incorporates the popular Super -Slides feature
that allows the installer to easily test for supervision. "The
product also features a locking mechanism which secures the
product to the bracket without any screws showing.
The S-24/1-IS-24 also features the patented Checkmated -
Instant Voltage Verification feature which allows the installer
to check the voltage drop draw and match it to the blueprint.
The S-24 & 1 [S-24 Series appliances are AN SI/UL 464 and
ANSVUL 1971, 'listed for use with fire protective systems
and are warranted for three years from date of purchase.
0,
Technicalis ti
Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com
8830054-REV C 6/17 PAGE 1 OF 4
SWITCH POST i'ION
y
TO1Vl:s
3
4
5
Mechanical Temporal 3
ON
ON
ON
Mechanical Continuous
OFF
ON
ON
2400 Ilz Temporal 3
ON
OFF
ON
2400 FIz Continuous
OFF
OFF
ON
Chine Temporal 3
ON
ON
OFF
Chime Continuous
OFF
ON
OFF
Whoop
ON
OFF
OFF
Whoop
OFF
OFF
OFF
Switch Positions 1The
and 2 in the OFF
position to select
isolated horn and Strobe power inputs
• Switch Position 6 ON =
HIGH d13A
• Switch Positron 6 OFF
= LOW d13A
CandelaSelection
Super Slide@ Mounting Bracket
Allows the installer to pre -wire the system, test for system
supervision, remove the signal head until occupancy, switch
out signals without changing mounting brackets and has
locking edge connector for snap -in -place installation.
Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 m www.pottersignal.com
8830054R V C 6/17 PAGE 2 OF 4
S-24 24 VDC Selectable Candela, Lew
Profiletr
Model Nominal
Candela (ANS11UL
fart Number
Number Voltage
1971)
S-24WR 4890010 24 VDC
15, 30, 60, 75, 110
-24WW4890011 24 VDC
1.5, 30, 60, 75, 110
n
Candela (ANSI./
Reverberant dBA at 10
In Anechoic Room at
Model Number Part Number
Nominal Voltage
UL 1971)
ft, perANSI/Fil, 464
10 It
HS-24WR 4890030
24 VDC 15, 30, 60, 75, 110
62-82
100
HS-24WW 4890031
24 VDC 15, 30, 60, 75, 110
62-82
100
S-24 & HS 24 Strobe Current Ratings
24 VDC (16 - 33 Volts)
4
Model Designations:
W = Wall mount
R = Red Faceplate W=White Faceplate
All units are available in plain (no lettering)
Plain units are non -returnable,
"ALERT" bezel available for order.
"A(r11NT"' bezel available for order,
Horn Mode
Florn Decibel Levels
Minimum SPL. at 10 ft. per Minimum SPL, at 1.0 It,
ANSI(UL, 464 (HIGH) per ANSUUL. 464 (LOW)
Horn Current Ratings
Regulated 24 VDC; Max
Operating r High Setting (mA)
Temp 3 (24001iz)
78 dBA
71* dBA
28 rnA
'Temp 3 (Mechanical)
76 dBA
70* dBA
25 mA
Temp 3 (Chime)
70* dBA
66* dBA
15 rnA.
Continuous (2400 Ilz)
81 dBA
74* dBA
28 mA
Continuous (Mechanical)
80 dBA
72* dBA
25 mA
Continuous (Chime)
70* dBA
66* dBA
15 mA
Whoop
82 dBA
69* d13A
56 mA
For nominal and peak ckirrent across ANSllt.!h regulated voltage range for filtered I)C power and unfiltered (FWR [Full Wave
Rectified]) power see installation manual.
= Potter does not recommend using a coded or pulsing signaling circuit with any of our strobe products.
* The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While
the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode.
* Operating the horn in this spode at this voltage will result in not meeting the minimum ANSI/Ul— 464 reverberant sound level
required for public mode fire protection service. ''hese settings are acceptable only for private mode fire alarm use. Use the high dBA
setting for public mode application (not applicable when using the chime tone, 'The chime tone is always private mode).
Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com
8830054-REV C 6/17 PAGE 3OF4
JI �
UL Listed
Control Signal
Panel
S.
S+ S- H+ H-
Supervised 8 0
Signal Circuit
n
UL Listed
Control
Signal
Panel
S- H+ H-
Supervised
Circuit
MSignal
END LINE
RESISTOR
Signal I Signal
S- H+ H- I S- F
END OF LINE
RESISTOR
END OF LINE
RESISTOR
Notes:
All strobes are designed to flash as specified with continuous applied voltage. Strobes should not be used on coded or pulsing signaling circuits.
However, use of the Potter AVSM control module or Gentex synchronization protocol is permitted to synchronize the strobe, horn, and/or mute the horn.
® FOR SYNCHRONIZATION WIRING INFORMATION, REFERENCE AVSM CONTROL MODULE DATA SHEET (8830050) AND/ORAVSM
CONTROL MODGLE MANUAL FOR 5YNCEIRONIZATION M()DUI,E WIRING DIAGRAMS. AVSM CONTROL MODULE DATA SHEET AND
Iv1ANLiAL. CAN BE OBTAINED AT http://pottersignal.coni OR CALL POTTER ELECTRICTEC;IINICAL SUPPORTAT 1-366-956-1211
The audible and/or visible signal shall be Potter S-24 strobe and Potter lIS-24 horn/strobe Series or approved equal and shall be
listed by Underwriters Laboratories, Inc. per ANSIAJL 1.971 and/or ANSI/[TL 464. `The notification appliance shall also be listed with
Factory Mutual Listing Service (FM) and the California State lire Marshal (CSFM).
The notification appliance (combination audible/visible) shall produce a peak sound output of I OOdDA or greater at 24VDC as
measured in an anechoic chamber. The signaling appliance shall also have the capability to silence the audible signal while leaving the
visible signal energized with the use of a single pair of power wires. Additionally, the user shall be able to select either continuous or
temporal tone output with the temporal signal having the ability to be synchronized.
Unit shall be capable of being installed so that any unauthorized attempt to change the candela setting will result in a trouble signal at
the fire alarm control panel.
The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of I liz or up to 2Hz regardless of power
input voltage. The strobe appliance shall have an operating current of 42mA or less at 24VDC for the 15Cd strobe circuit.
The appliance shall be polarized to allow for electrical supervision of the system wiring. The unit shall be provided with a mounting
bracket with terminals and barriers for input/output wiring and be able to mount to a single gang or double gang box or double
workbox without the use of an adapter plate. The unit shall have an input voltage range of 16-33 volts with either direct current or full
wave rectified power for 24VDC models.
The appliance shall be capable of testing supervision without disconnecting wires, verify voltage without removing unit and be
capable of mounting to a surface back box.
Potter Electric Signal Company, LLC St. Louis, MC Phone: 800-325-3936 www.pottersignaLcom
8830054-REV C 6/17 �� PAGE 4 OF 4
Fixed candela options: 15, 110, and 177
Jumper Selection for normal or loud dBA
Input terminals accept 12 to 18 AWG
Super -Slide Bracket - Ease of Supervision Testing
Check-matek - Instant Voltage Verification
Temporal 4 pattern available when used with compatible panels
Prewire entire system, install mounting bracket, then install
signals
Silence signal while visual appliance will remain flashing (for
use in accepted jurisdictions.
Faceplate available in red or off-white
Wall mount
Five year warranty
Description
The LFHS is a high quality, low profile., low frequency audible
and visible appliance that offers a dependable audible and visual
alarm, The LFHS is ideal for any occupancy that requires low
frequency notification appliances. The LFHS horn offers a 520
Hz square wave.. temporal 3 tone., . jumper selection is available
for normal or loud decibel tone. The LEAS is available in a fixed
15, 110 and 177 candela strobe. Atemporal 4 pattern is available
when used with compatible panels or GTsm sync module. "The
LFHS is available in a fixed 15, 110, or 177 candela strobe,
'The LHIS is shipped with a standard 4" metal mounting
plate which incorporates the Super-Slide0k) feature that allows
installers to easily test for supervision. The product also features
a locking mechanism which secures the product to the bracket
without any screws showing.
The LFHS also features the patented Checkmate - Instant
Voltage Verification feature which allows the installer to check
the voltage drop and match it to the blueprint.
The LFHS series appliances are ANSI/ITI, 464 and ANSI/
UL 1971 listed for use with fire protective systems and are
warranted for five years from date of purchase,
Technical Specifications
LISTED
Potter Electric Signal Company, LI-C St. Louis, MO a Phone: 800-325-3936 www.pottersignal.coni
8830119-REV A 2117 PAGE 1 OF 4
00=110"
00 C�D
RED WIRES
0 BLACK WIRES 0.
0
0 CAUTION: A jumper card
provided to test for correct
iwiring in the supervisory
[mode only.
WORCE PROVER —INSTALLATION OF
iBRACKET IS AS SHOWN IN ABOVE 5NO-MCCOPTIONAL L—OUD-1
IDIAGRAM. WIRE TERMINAL BLOCK 'DECIBEL INSTALL JUMPER.
[FEATURED ON RIGHT
It is often necessary to confirm the voltage drop along a line of
devices. The access holes are provided in the back of the terminal
block to allow the voltage to be measured directly without removing
the device. Typically this would be done at the end of the line to
confirm design criteria. Most measurements will be taken using the
S+ And S- locations although access is provided to other locations.
Notice: Care should be taken to not short the test probes.
Allows the installeor r to pre-wi re
the system, test fsystem
supervision, remove the signal
head until occupancy, switch
out signals without changing
mounting brackets and has
in -place installation
Potter Electric Signal Company, LLC
To remove bezel,
squeeze top and
bottom of bezel
St. Louis, MO
8830119-REV A 2117
Phone: 800-325-3936 www.pottersignal.com
PAGE 2 OF 4
(E)POTTER LFHS Series
g the Symbol of Protection Low Frequency HornlStrobe
Ordering Information
Model Part Nominal Candela
Number Voltage (VDC)
LFHS-177W 4890075 24 VDC 177 Cd
LFHS-177R 4890076 24 VDC 177 Cd
LFIIS-11aW 4890077 24 VDC 110 Cd
L.FI1S-110R 4890078 24 VDC 110 Cd
LFHS-15W 2489EO080
79 24 VDIC 15 C.d
LFHS-15R 24 VDC 15 Cd
Note: R = Red faceplate, W = White faceplate. All units are plain (no
lettering).
ALERT and FIRE bezels available for order.
Horn/Strobe Current Ratings
24VDC Nominal Horn/Strobe Current Ratings (mA) Over Input Voltage Range of 16-33V (mA)
Regulated Regulated Regulated Regulated
24VDC 24VDC. 24VFWR 24VFWR 24VDC; 24VDC; 24VI�WR 24VFWR
Candela horn Mode Operating Operating Operating Operating Max. Max:. Max. Max.
Current Current Current Current Operating Operating Operating Operating
(NORMAL) (LOUD) (NORMAL) (LOUD) Current Current Current Current
(NORMAL.) (LOUR) (NORMAL) (LOUD)
15 'temporal 3 112.0 mA 144.0 nub 163.0 mA 198.0 mA 124.0 mA 1810 mA 201.0 mA 252.0 mA
520 I°Iz
15 Temporal 4 158.0 mA 175,0 mA 210 0 mA 269 0 mA 195,0 mA 2910 mA 273,0 mA 339.0 mA
520 Hz
110 Temporal 3 193.0 mA 223.0 mA 259,0 mA 295.0 nuA 280.0 mA 326.0 mA 348.0 mA 427,0 nut
520 1 [z
110 Temporal 4 241.0 mA 29 1. 0 mA 325.0 mA 383.0 mA 384,0 mA 474.0 mA 470n mA 555,0 mA
520 Hz
177 Temporal 3 268,0 mA 293.0 mA 325.0 mA 329.0 mA 365.0 mA 393.0 mA 465.0 mA 478.0 mA
520117
177 Temporal 4 337.0 mA 391.0 mA 428.0 mA 477.0 mA 427.0 mA 525.0 mA 693.0 mA 759.0 mA
520 Hz,
Minimum SPL at Minimum SPL at
Horn Mode l 01't. Per ANSI/1? 1, 1 Oft. Per ANSI/
464 (NORMAL) UL 464 (LOUD)
Temporal 3 520 Rz 76.3 dBA 78.8 dBA
Temporal 4 520 Hz 80.6 dBA 82.0 dBA
Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com
88,0119-REV A 2/17 PAGE 3 OF 4
.'A
4
� N
UL Listed
Control Signal Signal
Panel
Supervised B 0 0
Signal Circuit
\ it END
LINE
RESISTOR
//Vo NOT Ifd�lll@I II /
OOP
\ o
Red Wires
S+
0 Black Wires S-
Optional Loud
�i+
Bi-
Decibel Install
um per
OQ
\ l i
" �.i` O
,Voles
The LFHS is not listed for outdoor use.
For nominal and peak current across ANSI/UL regulated voltage range for filtered 13C; power and unfiltered (FWK [hull Wave
Rectified]) power, see installation manual.
The sound output for the temporal 3 tone is rated lower since: the time the horn is off is averaged into the sound output rating,
This appliance is not recommended for use on coded or pulsing signaling circuits and is NEPA 72 Compliant.
Architect and EngineeringSpecifications
The audible and visible appliance shall be Potter Electric Signal Company model LFHS. The appliance shall be listed with Underwriters
Laboratories (ANSI/t II ) for use with fire protective signaling systems (ANSI,`IJL 1971 and ANSTIUL 464) and with CAN/ULC S526 and
CAN/ULC S525 with intended use in fire alarm systems. The LFIiS will produce a peak sound output of at least 75 d13A as measuredd in
an anech,oic chamber. The EMS shall also maintain a minimum flash rate of I Hz or up to 2 Hz regardless of power input voltage, The
strobe appliance shall have an operating current of 365 mA or less for the 177 candela strobe circuit with the horn set at the N(OPMAL,
setting. TThe appliance shall be polarized to allow for electrical supervision of the systetn wiring, The unit shall be provided with a
mounting bracket with terminals and barriers for input/output wiring and be able to mount to a single gang or double gang box or double
workbox without the use of an adapter plate. The LF1IS shall be mounted on the wall. 'The unit shall have an input voltage range of 16-
33 volts with either direct current or full suave rectified power at 24 'v DC. The appliance shall be capable of testing supervision without
disconnecting wires, verify voltage without removing unit and he capable Of Mounting to a surface back box.
Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com
8850114-REV A 2(] 7.� PAGE 4 OF 4
m
50
(E)POTTER LFH Series
The Symbol of Protection Low Frequency Audible Sounder°
Features
® Super-ShdeR Bracket — Ease of Supervision 7:esting
'Walt or Ceiling mount
Check mateV, — Instant Voltage Verification
Synchronize from with Potter OTSM module
Produces a 520flz square wave, temporal 3 tone
Jumper selection for normal or loud dBA
• Temporal 4 pattern available when used with GTSM module
Tamperproof re-entrant style grill and locking screw (Optional)
® Faceplate available in red or off white
5 year warranty
Application
The LFFI Series is a high quality, low profile, audible appliance
designed to meet the NFPA 72 requirements to install low :frequency
(520Hz) signaling in sleeping rooms.
�rhe LFFI horn offers a 520Hz square wave, temporal 3 tone. A jumper
selection is available for normal or loud decibel tone. A temporal 4
pattern is available when used with the Potter C=TSM Synchronization
Control Module.
The Ull is equipped with a universal 4" metal mounting bracket
which incorporates the popular Super-Slidet feature that allows the
installer to easily pre -wire the system and test for supervision. 'Fhe
product also features a locking mechanism that secures the signal to
the bracket without showing any screws and the Check-matek - Instant
Voltage Verification Feature which allows the installer to check the
voltage drop, currant draw, and match against the blue print.
Product Listings
® Listed to ANSIfUL 464 and CAN/LILC S525
CSFNI: Pending
Technical Specifications
SIGNALING
�L
LISTED
S3247
Potter Electric Signal Company, LLC - St. Louis, MO w Tech Support: 866-956-1211 / Customer Service: 866-572-3005 • www.pottersignal.com
8830068 - REV A , 4115
PAGE 1 OF 3
i
Ordering Information Model Designations
"R" = Red
Model Number Stock Number Body Color
LFIi-24,R 4890070 Red "W" = White
LF11.24W 4890071: Off -While 11 units are plain (no lettering)
Horn Levels: Reverberant Room
Minimum dBA at
Minimum dBA at
horn Setting 10, Per UL 464
10, Per Ul:., 464
(NORMAL)
(111GII)
Temporal 3 520 liz 77.8 dBA
79.8* dBA
Temporal 4* 520 Hz 81.5 dBA
83,4* dBA
24VDC Normal Horn Current Rating (mA)
Horn Setting
24VDC Operating
Current (NORMAL)
24VDC Operating
Current (LOUT`)
24VFW R Operating
Current (NORIVIAL)
I24VFW'R Operating
Current (LOUD)
'Temporal 3 520 flz
72.1 mA
120.I nrA
104.6 mA
158A mA
Temporal 4* 520Itz
75.9 mA
116.0 mA
108.1 mA
182.0 rnA
Horn Current Ratings Over Input Voltage Range of 16-33V (mA)
Regulated 24VDC
Regulated 24VDC
Regulated 24V17WR
Regulated 24VFWR
Rom Setting
Max Operating
Operating Current
Max, Operating
Max. Operating
Current (NORMAL)
(LOu ))
Current (NORMAL)
Current (LOUD)
Temporal 3 52011z
99.4 mA
155.8 mA
152.1 mA
213.5 mA
Temporal 4* 520 liz
100,1 mA
157.2 tnA
1611 nvA
235.2 m-A
'Temporal 4 520 Hz, measured per AN SFUL 2075
® For nominal and peak current across ANSI/U-L, regulated voltage range for filtered DC power and unfiltered (FWR [Full. Wave Rectified]) power,
see installation manual.
® The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating.
RMS current ratings are per AN S11UL average RMS method. ANSI/UL max current rating is the maximum RMS current within the listed voltage
range (16-33VOC for 24VDC units). For unfiltered FWR ratings, see installation manual.
* Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/t L 464 reverberant sound level required for public mode
fire protection service. These settings are acceptable only for private mode fire alarm use. Use the high dBA setting For public mode application (not
applicable when using the chime tone. The chime tone is always private mode).
Potter Electric Signal Company, LLC m St. Louis, MO ° Tech Support: 866-956-1211 / Customer Service: 866-572-3005 - www.pottersignal.com
8830068 - REV A , 4/ 15 PAGF 2 OF 3
UL Listed
Control Signal Signal
PanelS-
H+ H-
SupervisedLT�Lft
C 0 @ 0
Signal Circuit
Eno of urvE
RESISTOR
Checkmate® Instant Voltage
Verification
It is often necessary to confirm the
voltage drop along the line of devices.
The access holes are provided in
the back of the terminal block to
allow the voltage to be measured.
directly without removing the device.
Typically, this would be done at the end
of the line to confirm design criteria.
Most measurements will be taken.
using the S+ and S- locations although
access is provided to other locations.
AOTL'. Care should be taken to not
short the test probes,
This appliance is not recommended for use on coded or pulsing signaling
Circuits.
The four pulse temporal pattern (temporal 4) can only be obtained on this
product when used in conjunction with the Potter GTSM Synchronisation
Module
• See GTSM Control Module Manual (???) for synchronization module
fairing diagram. GTSM Manual can be obtained at
wow.PottersignaLcom/fzre or call Potter Technical Support 1866-956-1211
s # t hocking S
# (optional)
Nonuaal-loud decibel
jumper. For loud
decibel install jumper
Super Slide® Mounting Bracket
Allows the installer to pre -wire the
system, test I,or system supervision, Locking S,
remove the signal head until (optional)
occupancy, switch out signals without
changing mounting brackets and has
locking edge connector for snap -in -
place installation.
Slide onto bracket
The alarm horns shall be Potter model LFII. The appliance shall be listed with Underwriters Laboratories (_> NSI/UL) for use with fire protective
signaling systems (AINTSh'tsL 464) and with CAN/lJLC S525 with intended use in fire alarm systems. The LFH will produce a peak sound output of
88.3 dBA as measured man anechoic chamber. The appliance shall be polarized to allow for electrical supervision of the system wiring. The unit shall
be provided with a mounting bracket with terminals and barriers for input/output wiring and be able to mount to a single gang or double gang box. or
double workbox without the use of an adapter plate. The unit shall have an input voltage of 16-33 volts with either direct current or full wave rectified
power at 24 VDC. The appliance shall be capable of testing supervision without disconnecting wires, verity voltage without removing unit and be
capable of mounting to a surface back box.
Potter Electric Signal Company, LLC a St. Louis, MO . Tech Support: 866-956-1211 / Customer Service: 866-572-3005 - www.pottersignal.com
ISO 9001. nnn I DESIGNING, MANUFACTURING,
` ' 8 DISTRIBUTING QUALITY SYSTEMS 8830068 - REV A , 4/15 PAGE 3 OF 3
D -HW Seide-%,s
TK 1-
Parallel Coinffiected Suirge Protective Device
DITEK's DTK-HW Series of surge protective devices art
designed and manufactured to meet the standards of the life
gafety industry. These compact, parallel -mount SPD's are
v.vailable for 120V, 240V and 120/240V systems; and are widely
used to protect fire alarm panels and other dedicated branch
circuit loads. Their small footprint enables installation in a variety
if locations.
Product, Features
> Approved for 20A circuit breakers
NEMA 4X weatherproof enclosure
allows for use in harsh environments
Diagnostic LED provides positive
indication of system power and SPD
function
> Complies with ANSI/IEEE C62.41
and C62.45 Category B standards
Applications
> Fire Alarm Control Panels
> Residential Electrical Panels
>- Equipment Panels
�- Pumps, Motors, Lift Pump Stations
Accessories
> DIN Rail Mounting Kit, p/n DTK-DRK
1-1 MADE IN
jjj;�C I. US
LISTED 7-s.A'
Every precaution has been taken to ensure that this literature is accurate and complete. DITEK Corporation assumes no responsibility and disclaims all liability for damages resulting from the use of this information a for any errors or omissions
Series
Modilj,,:�r Lc,,,',,�w Voiltlagcsi�`.3.-,urge Protectors
DITEK's DTK-2MHLPB Series of low voltage surge
This series was designed for ease of installation, with
convenient field -replaceable modules and a Snap -Track
base system, allowing the installer to protect multiple
circuits while utilizing a common ground point.
101111WAAAMINVO
Product Features
x Protects (2) low voltage circuit pairs
per module
Hybrid design utilizing SAD and GDT
technologies
> Shorts to ground when compromised
> Field -replaceable modular design
with single point ground for fast and
easy installation
voltage configurations available
to protect various types of circuits
>- Hardwired multi -base mounting
system allows protection for up to
(10) pairs with a common ground
> Suitable for use on both AC and DC
low voltage circuits
Applications
)v Fire Alarm Panel NAC, SLC, PIV and
IDC Circuits
> Burglar Alarm Panel NAC and IDC
Circuits
> 70V Speakers and Audio Equipment
Low -Voltage Landscaping Lighting
and Lighting Control Circuits
4-20mA Current Loops
Accessories
> To order module with base, add
"WB" to end of part number
Test Module Kit, pin DTK-2MHLPTM
JW PA LISTED
Every precaution has been taken to ensure that this literature is accurate and complete. DITEK Corporation assumes no responsibility and disclaims all liability for damages resulting from the use of this information or for any errors or omissions.
Base Part Numbers and Dimensions
uI'K-2MHLPB Series
Modular Low Voltage SUrge Pnc,,,tectors
011m,"'Ar