Loading...
HomeMy WebLinkAbout22-4036City of Zephyrhills{€ a\taa t 2?�\'€iz�titi 5335 Eighth Street Zephyrhills, FL 33542 BGR-004036-2022 Phone: (813) 780-0020 Fax: (813) 780-0021 Issue Date: 05109/2022 12 26 21 0280 00000 0470 39418 Kennedy Avenue .,4 €.a. `4z 'ti.\i'.. X.,:.;�.> tz.ti x;�, zi �;,gr�,,a t 4't wg MIL t to\ty��r `�C ��i � ��tit *3 , i t ",1 j�;S k31 t1 . \ is s t \ 4J \ \ t =d;t ,, \u , z\lk\ xn \t., ,1 % { 7 l' y \ Name: ELIZABETH DAFFRON Permit Type: Building General (Residential) Contractor: TITAN SOLAR POWER FL Class of Work: Electric Service Replacement/ INC Address: 39418 Kennedy Ave ZEPHYRHILLS, FL 33542 Building Valuation: Electrical Valuation: $14,400.00 Mechanical Valuation: Plumbing Valuation: Total Valuation: $14,400.00 Total Fees: $112.00 Amount Paid: $112.00 Date Paid: 5/9/2022 12:25:48PM INSTALL ROOF MOUNTED PV SOLAR SYSTEM. Electrical Permit Fee $112.00 REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent reinspection. •' r•• i. • ^• •. •' rii • • r•• 1i • • •i'-.. may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal ri i ,,,.. • .. `• ! , i i is ♦ ! • .:... i i . is ;. ! • • i.. •: accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C. NO OCCUPANCY BEFORE CONTRACTOR SIGNATURE PEfIT OFFICE() • n A r ri r WAA, r' 81s-78o-002o City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contactfor Permittin DAFFRON ELIZABETH_M Owner's Name C 39418 KENNEDY AVENUE, ZEPHYRHILLS, FL 33542 Owners Address C Fee Simple Titleholder Name C Nner Phone Number 813 369-1285 Airier Phone Number_ rimer Phone Number Fee Simple Titleholder Address JOB ADDRESS 39418 KENNEDY AVENUE, ZEPHYRHILLS, FL 33542 LOT # 47 SUBDIVISION LINCOLN HEIGHTS SUB PARCELID# 12-26-21-0280-00000-0 770 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR (X1 ADD/ALT SIGN DEMOLISH INSTALL REPAIR PROPOSED USE SFR 0 COMMOTHER TYPE OF CONSTRUCTION BLOCK FRAME STEEL DESCRIPTION OF WORK PV Solar Installation BUILDING SIZE I SO FOOTAGE HEIGHT =BUILDING VALUATION OF TOTAL CONSTRUCTION $38 000 =ELECTRICAL $ j (p AMP SERVICE PROGRESS ENERGY W.R E.C. PLUMBING =MECHANICAL $ d VALUATION OF MECHANICAL INSTALLATION =GAS 4 I ROOFING = SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO 1 BUILDERF I COMPANY SIGNATURE REGISTERED YIN FEE CURREN Y r Ni Address � v License # L ELECTRICIAN COMPANY �S ��° a _ SIGNATURE REGISTEREC Y1Nf FEECURREN� YiN - Address Y License# PLUMBER COMPANY SIGNATURE REGISTERED YIN I FEE CURREN Y I N Address License# MECHANICAL COMPANY I _ SIGNATURE REGISTERED YIN FEE CURREN Y! N Address License #— OTHER COMPANY SIGNATURE REGISTERED Y I N� FEE CURREN E YImN� - Address License # E� RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans wl Silt Fence installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans, —PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement Is required, (A)C upgrades over $7500) Agent (for the contractor) or Power of Attomey (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Remofs if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage) Driveways -Not over Counter if on public roadways..needs ROW 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not property licensed and is not entitled to permitting privileges in Pasco County, TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. if the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500,00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department or Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction.. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection --Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. Southwest Florida Water Management District -Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers -Seawalls, Docks, Navigable Waterways, Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency -Asbestos abatement. Federal Aviation Authority -Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone W" unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT FLORIDA JURAT (F.S 11 T03) r� OWNER OR AGENT CONTRACTOR' Subscribed and swom to (or affirmed) before me this Subscribed and sworn to (or affirmed) before me this by by Who is/are personally known to me or has/have produced VVho islare parsanall known to e or has/have produced as identification. as Identification. Notary Public Commission No, Na—of Notary typed, panted or stamped __ Notary Public Commission No. 241/Z4 Z110 Name of Notary typed, printed or stamped Notary Publici State as 201201 SYSTEM CAPACITY: 7.2 KW DC / &0 KW AC PV PANELS: (18) Q. PEAK DUO BLK ML-G 1 0+400W BY QCELL OPTIMIZERS: (18) P401 BY SOLAR EDGE INVERTER: (1) SE6000H-US BY SOLAR EDGE RACKING SYSTEM: CROSS RAIL SYSTEM 44-X BY K2 SYSTEMS PROJECT INFORMATION PROJECT LATITUDE 28.234783 :: MIN AMBIENT TEMP -1 .1 PROJECT LONGITUDE 1 82 MAX AMBIENT TEMP 34 -C TZ j­'"B_�-P-SURE C AHJ EPHYRHILLS CI � DESIGN WIND SPEED 138 MPH E-1 I ONE LINE RISER DIAGRAM E-2 SAFETY LABELS S-1 STRUCTURAL PLAN S-2 RACKING PLAN S-3 RACKING PLAN D-3 I INVERTER DATA SHEET 11110": 1 z I: I Zf 1-1 PER FL. STATUTE 377.705 (REVISED 7/1/2017), 1 RAFAEL A. GONZALEZ SOTO, P.E.83104 AN ENGINEER LICENSED PURSUANT TO CHAPTER 471, CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE. APPLICABLE CODES: 2020 FLORIDA BUILDING CODE 7TH EDITION, ASCE 7_16 MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES, FFPC 7TH EDITION, NFPA 2018, NFPA 70 AND NEC 2017, CONTRACTOR SHALL ENSURE ALL ROOF PENETRATIONS TO BE INSTALLED AND SEALED PER 2020 FLORIDA BUILDING CODE 7TH EDITION OR LOCAL GOVERNING CODE. ALL WIRING METHODS AND INSTALLATION PRACTICES SHALL CONFORM TO THE NATIONAL ELECTRICAL CODE (NEC) 2017. LOCAL STATE CODES. AND OTHER APPLICABLE LOCAL CODES. MEANS SHALL BE PROVIDED TO DISCONNECT ALL CURRENT CARRYING CONDUCTORS OF THE PHOTOVOLTAIC POWER SOURCE FROM ALL OTHER CONDUCTORS IN THE BUILDING. CONNECTORS TO BE TORQUED PER DEVICE LISTING, OR MANUFACTURERS RECOMMENDATIONS. NON -CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING. REQUIRED SAFETY SIGNS AND LABELS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE, OR OTHER MECHANICAL MEANS, LABELS SHALL COMPLY WITH ARTICLE 690 VI OF THE NEC 2017 OR OTHER APPLICABLE STATE AND LOCAL CODES. SEE LABELS AND MARKING PAGE FOR MORE INFORMATION. RACKING ROOF MOUNT SYSTEM SHALL BE INSTALLED FOLLOWING MANUFACTURERS INSTRUCTION SPECS, INCLUDING ALL GROUNDING WEEB CLIPS, GROUND LUGS, AND RAIL SPLICE KITS FOR ELECTRICAL CONTINUITY MECAWIND TOOL IS BASED ON THE C&C VIAND LOADS FOR ENCLOSED BUILDINGS. DESIGN WIND PRESSURES ARE CALCULATED USING ASCE 7-16 EQUATION 30.6-1. ALL NOTES IN FIGURES ASCE 7-16 30A-1 AND 304-2(A,B AND /67C) HAVE BEEN INCORPORATED MEAN ROOF HEIGHT MUST BE LESS THAN 60 FEET. DOCUMENT CONTROL DATE AB ' I ISSUED FOR PERMIT .7.722 �A. 1� REV DESCRIPTION DATE [CAD[ C (LOCATION MAP �) / WIND ZONES IRRADIANCE MAP 3D RENDERING N.T.S. "PROPERTY SIDE FACING STREET" PROPERTY LINE 1_� Al G01V,> < Lp 0 —9,3104 :0 ,4A s',�'I,V; I '"%OPTIDA m FE < z c) M m ROOF PLAN VIEWI BOS LOCATION ENGINEER CONTACT INFORMATION ENGINEERING STAMP CONTRACTOR CONTACT INFORMATION ENGIPARTNERS LLC Rafael A TITAN SOLAR POWER FL C.A. 32661 ...... Gonz I a ez 12221 N US HIGHWAY 301 255 GIRALDA AVE Soto CORAL GABLES, FL33134 THONCTASASSA, FL 33592 2022.05.04 DESIGN@ENGIPARTNERS COM (813) 982 -9001 11-44-49 833 - 888 - 3644 -04'00' #EC13008093 CONTRACTOR LOGO (&T I TA N S 0 L A R P 0 W E R FENCE PROPERTY LINE ELIZABETH DAFFRON 39418 KENNEDY AVE ZEPHYRHiLLS FL 33542 12 26-21-0280 00000-0470 SHEET NAME ROJECT ID ENGINEER OF RECORD: ENS RAFAEL A. GONZALEZ SOTO, PE TSP1228 30 DATE. SHEET TITLE: C-1 DATE: 05-03-� Em "PROPERTY SIDE r q r FACING I �pi r PROPERTY� ISSUED FOR PERMIT REV DESCRIPTION NORTH N 's���%/ f 0 * � I of w } iy 01 m —I I m <; Z r- I C Z m PLAN I (D.SqAFETY M.T.S. I DOCUMENT CONTROL DATE JCAC QC I ENGINEER CONTACT INFORMATION 0"4-22 AD JC ENGIPARTNERS LLC DATE CAD QC C.A. 32661 255 GIRALDA AVE CORAL GABLES, FL 33134 DESIGN@ENGIPARTNERS.COM 333 - 888 - 3644 FENCE PROPERTY LINE ENGINEERING STAMP CONTRACTOR CONTACT INFORMATION Rafael A TITAN SOLAR POWER FL Gonzalez 12221 N US HIGHWAY 301 Soto THONOTASASSA, FL 33592 -2022.05.04 1 1:44:59 (813) 982 -9001 -04'00' #EC13008093 I CONTRACTOR LOGO O A S O L A R P O W E R LOCATION OF NEAREST URGENT CARE FACILITY NAME: ADDRESS: PHONE NUMBER: NOTES: 1. INSTALLERS SHALL DRAW IN DESIGNATED SAFETY AREA AROUND HOME 2. INSTALLERS SHALL UPDATE NAME ADDRESS AND PHONE NUMBER OF NEAREST URGENT CAR FACILITY RELATIVE TO THE SITE BEFORE STARTING WORK ELIZABETH DAFFRON SAFETY P LA N 39418 KENNEDY AVE ZEPHYRHILLS FL 33542 PROJECT ID: ENGINEER OF RECORD: ENG. RAFAELA GONZALEZ SOTO, PE TSP122830 DATE: 12-26-21-0280-00000-0470 Jl-a3-22 0 1 WIRE SIZES, QUANTITY & TYPE RACEWAY SIZE, TYPE & LOCATION ADDITIONAL INFORMATION WIRE AMPACITY CALCULATIONS WIRE DE -RATED CALCULATION RACEWAY 125% OF VOLTAGE CONE) CONDUCTOR N UTRAL OUND I HAULWAY RACEWAY HEIGHT OUTPUT OUTPUT N AMBIENT #OF DIST. VOLTAGE QTY. SIZE & TYPE QTY. SIZE & T SIZE &TYPE SIZE & TYPE LOCATION CURRENT OCPD WIRE i DE -RATES WIRE TAG ABOVE ROOF CURRRENT MI TEMPERATURE CONDUCTORS 1 E OR I COEFFICIENT COEFFICIENT DC (BEFORE JB) (4) #10 AWG PV WIRE N/A (1) #8 AWG BARE COPPER :i NOT APPLICABLE UNDER ARRAY 1/2" TO 3-1/2" 15A 18.8A LVERTER TO METER) (2) #8 AWG THWN-2 (1) #8 AWG THWN-2 (1) #8 AWG THWN-2 3/4" EMT CONDUIT 1 EXTERIOR WAL 2 3125A 1 55A 5 FT240V 0.1% 7.7% - - --- -I-,--,- � I ---I'-,-- - ---- - - - I ---- - -- -I--,--,-------- _ _ _ __h - -- 11 -- - I , - -- - - - , - - ---- - - -- STRING #1 5 STRING #2 041 8 NEW UNDERGROUND SERVICE 24U\V12OV 3#3/0 THVVN-2 TER INVERTER TOTAL OUTPUT: 25A SAFETY RATING (12596): 31.25A TOTAL PVSYSTEK8 {}CPD: 40A ~ K�A|NBREAKER RAT|N��: 150A BUS BAR RATING: 200A 2#4THVvN-2GROUND GROUNDING ROD SHALL N|�U�8FT NOT BELESS THAN (50IN) METAL WATER PIPING SYSTEM SHALL BE BONDED AS REQUIRED IN PER CODE NEC 25O1VuAC DISCONNECT MUST BE `- KAILE, VISIBLE ADJACENT TO AND V0 THIN | 3 NEMA3R JUNCTION BOX REFER TO D-1 SHEET 2 1 #8 BARE WIRE GROUND 3/4" MT CONDUIT 4 1 #8 THV\/N-2 GROUND 5 6 REFER TO D-3 SHEET 1 #8 THWN-2 NEUTRAL 3/4" EMT CONDUIT 7 1 PV SYSTEM DISCONNECT - 60A RATED 8 PV INTERCONNECTION POINT - PV BREAKER 9 NEW NUTILITY ELECTRICAL SERVICE DOCUMENT CONTROL DATE CADIQCI ENGIN ER CONTACT INFORMATION ENGINEERING STAMP CONTRACTOR CONTACT INFORMATION CONTRACTOR LOGO A CUSTOMER: ELIZABETH DAFFRON SHEET NAME: ONE LINE RISER DIAGRAM ISSUED FOR PERMIT 05-04-22 AD ENGIPARTNERS LLC CA32661 Rafael A TITAN SOLAR POWER FL Gonzalez 12221 N US HIGHWAY 301 REV DESCRIPTION DATE _:LC CAD QC PROJECT ADDRESS: PAL GABLES, FL 33134 THONOTASASSA, FL 33592 11-45-09 PARCEL NUMBER: TURN RAPID SHUTDOWN SWITCH TOne"O= POSIT ION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD mTHE ARRAY. . . LABEL AC DISCONNECT, POINT OFINTERCONNECTION PER CODE: NEC 89O]3(B) /^PPI /nr^rx`m- ACDGC0NNECTMAINPANEL PER CODE: NEC 110.27 (C) OSHA 1910.145(f)(7) /^Pp /m^^nom- ACD|SCONNECT, MAIN PANEL PER CODE: NECO3O.56(C)(5) /^nP/ /or^nnm- m�,umumvmo~/ POINT 0FINTERCONNECTION PER CODE: NEC 690.5G(C) ACDISCONNECTMAINPANEL POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: LABEL LOCATION: INVERTER PER CODE: NEC 690.52 LABEL LOCATION: INVERTER PER CODE: NEC 89O.53 /^on /nr^nnm� M,u/o^m"wo./ PER CODE: NEC 690.54 LABEL LOCATION: AC DISCONNECT /uun /nrunom. wm/mocnviuco DISCONNECT, DCCONDUIT \\\\\)//A/ /^PP/ /nrxr/nm- rum/ur INTERCONNECTION LABEL LOCATION: POINT OF INTERCONNECTION PER CODE: NEC /uuP/ /m-unom, MAIN SERVICE PANEL PER CODE: NEC GAU.45(B)(5) POINT OF INTERCONNECTION PER CODE: NEC 09O33(E)(2)&NEC LABEL LOCATION: POINT 0FINTERCONNECTION PER CODE: NEC 69015, NEC 690.13(B) LABEL LOCATION- ADJACENT TOMAIN DISCONNECT (OTITZ.3L N , O GENERAL NOTE: ADHESIVE FASTENED SIGNS: —110. �THELABEL SHALL BEVISIBLE, REFLECTIVE AND SUITABLE FOR '� = HEENV|RONK8ENTVVHERE|T|SINSTALLED [WFPA1.11122.1] of WHERE REQUIRED ELSEWHERE |NTHIS CODE, ALL FIELD APPLIED LABELS, WARNINGS, AND MARKINGS SHOULD � ~~ 0100, COK4PLY��THANSI Z535.4[NEC 11O.21(B)FIELD MARK|N(�]. ��10��x�'/>` ADHESIVE FASTENED SIGNS MAY BEACCEPTABLE |F PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [|FC8O5.11j.3] DOCUMENT CONTROL DATE CADJQCJ ENGINEER CONTACT INFORMATION ENGINEERING STAMP C NTRACTOR CONTACT INFORMATION CONTRACTOR LOGO CUSTOMER: ELIZABETH DAFFRON _PROJ ADDRESS (&T I TAN PARCEL NUMBER: SHEET NAME: SAFETY LABELS ISSUED FOR PERMIT ENGIPARTNERS LLC Co Rafael A TITAN SOLAR POVVER FL REV DESCRIPTION DATE CALICO DATE SOLAR MODULE UL 1703 CERTIFIED MAX DESIGN LOAD 56 psf APPLIED WIND LOAD-45.61 psf NOTES Q.PEAK DUO -INSTALL MID CLAMPS BETWEEN BLK ML-G10MODULES AND ENDS CLAMPS AT THE - 40OW I END OF EACH ROW OF MODULES. -ALUMINUM RAILS SHOULD ALWAYS BE SUPPORTED BY MORE THAN ONE FOOTING ON BOTH SIDES OF THE SPLICE, WORST CASE MODULE: ZONE 1: 33% ZONE 2r: 67% -45.61 (0.33) + -45,61(0.67) _ -45.61 psf ULTIMATE WIND SPEED 1401mph DESIGN WIND SPEED 1381mph RISK CATEGORY 11 EXPOSURE CATEGORY C ROOF SLOPE 14 ROOF TYPE GABLED MATERIAL ROOF TYPE ASPHALT SHINGLES PRESSURE ZONE: 1&2 MEAN ROOF HEIGHT 11.569' 0.5 MEAN ROOF HEIGHT 5.78450b 2H2 8 PERIMETER WIDTH: 3.00_' KID 0.85 KZT 1.0 KH 0.849 VELOCITY PRESSURE (q) = 0.60*0.00256* KHKZTKDV' VELOCITY PRESSURE (ASID) 21.72 NON EXPOSED EDGE FACTOR: 1 0 YE= EXPOSED EDGE FACTOR, 1.5 tE= ARRAY EQUALIZATION IFACTOR: I Ya =10.7 EXTERNAL PRESSURE COEFFICIENT Z1 0.7 -2.0 EXTERNAL PRESSURE COEFFICIENT Z2e 0.7 .0 EXTERNAL PRESSURE COEFFICIENT Z2n 0.7 _-2 -3,0 EXTERNAL PRESSURE COEFFICIENT Z2r 0.7 -3.0 EXTERNAL PRESSURE COEFFICIENT Z3e 0.7 -3.0 EXTERNAL PRESSURE COEFFICIENT Z3r 0.7 -3.6 INTERNAL PRESSURE COEFFICIENT 0.18 ZONES PRESSURES (PSF) NON EXPOSED PRESSURES (PSF) EXPOSED PRESSURES (PSF) MAX SPAN (FT) MAX CANT]- LEVER (IN) 1 -47.36 -30.41 -45.61 4' 16 1 2el -47.36 -30.41 -45.61 4' 16' 2110M -69.08 -45.61 -68,42 4' 16 -69.08 1 -45.61 -68,42 4 16 _Le 3'M -82,11 1 -54.73 -82.10 2 8 TOTAL ROOF AREA 1661,91 sq.-ft TOTAL MODULES: 18 TOTAL PHOTOVOLTAIC AREA 380.44 sq.-ft TOTAL PERCENTAGE AREA OF PV SYSTEM 22.891% WIND LOAD (PSF): -45.61 TOTAL WIND LOAD (LBS): -17,351.87 TOTAL ROOF MOUNTS: 58 TENSION FORCE PER MOUNT (LBS): -2T9.17 -LEGEND & SYMBOLS OBS ROOF OBSTRUCTIONS ARRAY # XxMODULE# -'<------STRING # NON -EXPOSED MODULES EXPOSED MODULES EDGE MODULES TRUSSES OR RAFTERS ROOF MOUNTS & RAIL > ROOF SLOPE ROOF'S GENERAL NOTES: 1- CONTRACTOR/INSTALLER TO VERIFY ROOF CONDITIONS FOR PROPER INSTALLATION OF THE PV SYSTEM. 2- CONTRACTOR/INSTALLER TO NOTIFY THE OWNER IMMEDIATELY OF ANY ROOF DEFICIENCIES AND/OR REPAIR REQUIRED TO INSTALL THE PV SYSTEM. 3_ FOR DOES NOT ASSUME ANY RESPONSIBILITY FOR THE INSTALLATION OF ANY PV SYSTEM ON DEFICIENT ROOFS. 4-CONTRACTOR/INSTALLER ASSUMES ALL RESPONSIBILITY TO INSTALL AS PER MANUFACTURER STANDARDS. A PANEL IS DEFINED AS EXPOSED IF D1 TO THE ROOF EDGE >0.5H AND ONE OF THE FOLLOWING APPLIES: 1. D1 TO THE ADJACENT ARRAY > 4 FT (1.2 M) OR Z D2 TO THE NEXT ADJACENT PANEL> 4 FT. (1.2 M) ASCE 7.16 - 29A-7 DESIGNED WIND PRESSURES. p = qh (GC P) (YE) ( Ya) 1 10 100 1000 Effective Wind Area, ft2 V ELECTRIC METER )ISCONNECT STRING INVERTER #1 i BOX - TYP. SEE D-1 LOCATED AT CENTER LOCATION - INSTALLER OF ROOF TRUSS - TYR MUST VERIFY IN FIELD LARRAY A TILT=14 AZIMUTH= 180' (S) H,= 4" In DOCUMENT CONTROL DATE [CAID QC ENGINE ER CONTACT INFORMATION ENGINEERING STAMP CONTRACTOR CONTACT INFORMATION CONTRACTOR LOGO CUSTOMER ELIZABETH DAFFRON PROJECT ADDRESS: . 118 KENNEDY AVE *TIT AN SHEET NAME STRUCTURAL PLAN ISSUED FOR PERMIT 05�04-22 AD 2C I ENGIPARTNERS LLC Rafael A C A. 32661 Gonzalez 255 GIRALDA AVE Soto TITAN SOLAR POWER FL 12221 N US HIGHWAY 301 REV DESCRIPTION DATE CAD QC 7� PROJECTID:ENGINEER OF RECORD: SHEET TITLE: CORAL GABLES, FL 33134 THONOTASASSA, FL 33592 ZEPHYRHILLS FL 33542 2022.05.04 S 0 A R P 0 W E R ��H R�FA F FLA GONZALEZSOTO PE S-1 DESIGN@ENGIPARTNERS.COM 11:45:3 0 (813) 982 -9001 PARCEL NUMBER: DATE: 833 - 886 - 3644 -04'00' #EC13008093 12-26-21 0280-00000-0470 05-03-22 ATTACHMENT DIAGRAM 2 ROWS OF RAILS PER MODULE LENG�N ct0���� K2 SYSTEMS CROSS RAIL CROSSRAIL YETI END 13MM HEX BOLT LOCK WASH 2X4 RAFTERS 24" O.0 SPLICE FOOT j \- -- ASPHALT SEE DATA SHEET ABOVE SHINGLES P - SPECIFY MIN. EMBEDMENT OF 2.5" NOTE: 5/16" SS LAG BOLT SEAL BASE MOUNT TO EXISTING 5/16" SS FENDER WASHER ROOF UNDERLAYMENT WITH ROOF SEALANT AND MEMBRANE SEALANT SHINGLE ROOF MOUNT DETAIL & DATA N.T.S. DOCUMENT CONTROL I DATE CAD QC ENGINEER CONTACT INFORMATION ENGINEERING STAMP CONTRACTOR CONTACT INFORMATION ISSUED FOR PERMIT 1 05-04-22AO Jc ENGIPARTNERS LLC Rafael A TITAN SOLAR POWER FL REV DESCRIPTION DATE CAD OCR„ C.A. 32661 ur Gonzalez 12221 N US HIGHWAY 301 255 GIRALDA AVE =Soto CORAL GABLES, FL 33134 N>;' 2022.05.04 THONOTASASSA, FL 33592 -- DESIGN@ENGIPARTNERS. COAA ;45:40 (813) 982 -9001 833 - 888 3644 04 00'... #EC13008093 y Everest Ground Lug 140 mph Array Interior 72 72 72 62 62 62 58 0 psf C 7 to 20 Array Edge 62 62 62 52 52 52 47 LAG BOLT PULL OUT CALCULATIONS Spruce, Pine, Per inch Thread Depth 26611as SS Lag Bolt 5/16" x 4" Min, Thread Depth 0'-3" Wood Strength x Thread Depth = Pull Out Strength 266 lbs, x 3 in = 798 lbs. Allowable Pull Out Strength per Lag Boll 798 lbs. Max. Pull Out Strength Required per Lag Bolt 299A7 Lag Bolt Pull Out Strength Safety Factor 2 67 ASCE 7-16 Velocity Pressure gz10 = 0.00256Kz Kzt Kd V2 Where DISTRIBUTED LOAD CALCULATIONS PV MODULES & RACKING WEIGHT = (INDIVIDUAL MODULE WEIGHT + 3.5 LBS) " (MODULE CITY) = (52.00 LBS)' (18) = 936.00 LEIS PER SQUARE FEET (PSF) ARRAY LOAD = PV MODULES & RAC_KI_N_G A _ WEIGHT I TOTALARRAY AREA = 936.00 LES / 380.44 SOFT 2, 46 PSF' HENCE ROOF WILL CARRY THE ADDITIONAL SOLAR SYSTEM_ LOAD gz10 = ASCE 7-16 velocity pressure evaluated at mean roof height (psf) Kz = velocity pressure exposure coefficient Kzt — topographic factor Kd = wind directionality factor V = basic wind speed (mph) from ASCE 7-16 maps referred to as ultimate wind speed maps in 2020 FBC. As an example, for an array having an area of 158.04 sq.-ft., the total uplifting (resultant) force acting on the array would be -39.1 psf x 158.04 sq. ft. =-6,179.364 lb. Knowing this resultant force, the design engineer can now determine the number of attachment points and the size of the mounting hardware necessary to safely carry this load. Live Loads Live loads associated with photovoltaic systems are usually assumed to be distributed uniformly and are small, on the order of 4 psf or less. BOLT EXIST. 2x WD. TRUSSES OR RAFTERS PLACE BOLT AT C.L. OF TRUSS OR RAFTER SECTION "A -A" _._.... _ N T.S. Lag pull-out (withdrawal) capin, typical roof Lumber Douglas Fir, Larch Douglas Fir, South Engelman Spruce, Lodgepole Pine (MSR 1650 f & higher) Hem, Fir, Redwood (close grain) Hem, Fir (North) Southern Pine Spruce, Pine, Fir STAINLESS STEEL Lag screw specifications Specific s/a" shalt, " gravity per inch thread depth 0,50 266 046 235 0,46 235 0,43 0,46 0.55 0.42 212 235 307 205 (E of 2 million psi and higher grades of MSR and MEL) 0.50 266 Sources: American Wood Council. NDS 2005, Table 11. 2A, 11 3A. CONTRACTOR LOGO CUSTOMER: SHEET NAME: EL17ABETH DAFFRON %� (�'! %� %TITAN PROJECT ADDRESS: R/"�� KING PLA 39418 KENNEDY AVE ZEPHYRHILLS FL 33542 PROJECT O: ENGINEER OF RECORD: SHEET TITLE: S D L A. R P O W E R SP122830 ENG. RAFAELA GONZAL EZ SOTO, PE S-2 PARCEL NUMBER: TDATE: `�n• 12-26-21-0280-00000 0470 05 03-22 1 N +T70 I Lag Screw Installation Guidelines E1IAE,EL7ADE " "- We SnpP rt PV Systems 'ro�.a�i9 v-t-I so We it em=±9 t 1. Determine location for the Mount on roof by drilling through 0 o c: 9on o I t t .... N01ICE OEACCEPIANCE(NQ.A) the center of truss from bottom with 5/32" drill bit. K2 Systems, LLC 2. Mark mounting holes for Mount on underlayment. Mounting holes should be centered on the trusses. A'"08, h.bu d pt d by M fJ i C ttNit ., " 3. Drill 15/64" pilot hole. 4. Apply sealant to bottom of Mount. P NOA 10 b.. M Il I } { t d b i n N O d Iy P d fl 61 Dd N, d h Ill( th t DI D d y, "I� 4�® �'j, I, tt .uc p i _. i t II I _} t h Lh al3l } M, 5. Place Mount over roof underlayment with holes in roof. tt. tt p d h f I p t W 7llR t 'th `� z T✓' lh t b p t 1 I by 1i iM�d P d t C I Ilia ihi,p.. i wrc .d A, t _ 6. Apply sealant to bottom of Mount, apply sealant to lag screws g Splice Foot X and fasten Mount securely to trusses. DESCRI I Ki 1,F tE f I FtI,hi.gAi Star A9 t r 1PPR01 1L DOCUMENT: D N d I F d f RI h .0 p - I tb ) 7. Apply additional sealant to top assembly to be sure all P9f >I IL ,Iz a d Id rp IK �n t f P I tr 1 t 1 .d, i I t 4 a p p p penetrations are .Sealed. ARSSILE IMPACT RATING NUJ LABELING: F h b-,11til M< 1 6 1 ' IIt, Thread t II wi b t M D d C. [ N ( tni ipp,. d M17➢( l(1 1 :: h W "y > Notes: (1) must be embedded in the side gram of a Trusses or other structural member inte ral with the g RENEW11 fth VOA hll f ppi K hn. h- TERAllN ATTON fti BOA 'll }F h d Lth 6 1 building structure. p g r l P M fthi, NO NOA I­>i G h I II IIY tv t I NOA F t s&" v pcodu nd pry c m)tiY h Ilion ft NdA.h Iir f d .. NOA- hn `�'F b (2) Lag Bolts must be located in the middle third of the ADIERIISENENJ:I NOA,un,Ir cud�db,t,�w �Y,�,m,-D � ,,,,,FhCO.nndoli.wcd �'°a3 , a structural member. b :hay k d ma}Md'i. pin 1 N' . 7 y fh i�'01' {pin., cd t s entvi hD4 hull l,poe iddrothe itaer CTION opy tt Acul+y th or't 9i m.txor LN5PESh E , G+I'.Ca�la -� (3) These values are not valid for wet services. ul b1 ` p R, �D}T I sNOA -l- T[I p g I -dc $ C 1>It pl; nl duc 1 ned vM�ve ,—b Cadet IT. U-n, P.E. '�%+�`: .Firxry'p� htheeCrtkatzn'.B",k-a (4) This table does not include shear capacities. If,� addocnmcnit n "—d.y - Y<"., N� ExI D P i '1 MJ zza .-dr k5 :`n:ax mays necessary, contact a local engineer to specify lag ���"d�"W�- AIP 1Daw:heh ° e.. bolt size with regard to shear forces. (5) Install lag bolts with head ad washer flush to surface „z (no gap). Do nor over -torque. PART BI,.L OF MATFR ALS r SCR TOE AL:A Bonding and Grounding (6) Withdrawal design values for lag screw connections `ATel,,;; yi. COMPLETE ASSEMBLY - - - } _< 1 = liICE x iX_ I AT KJ A shall be multiplied by applicable adjustment factors 2 S L OC BU YI 3:TZ P N/A 0S REll' $JNIs 3 I 7A 1 3 2 1 �vN SCREW " r-. WASHER I SSAy. r +✓� WA 3 - T--° �1°x- SS FIN' $SS " N ^_- ?H if necessary.See table 10.3.1 in the American -.51 c ���Al J lSALN ;: ..„ GFNLT_E�P' 1., _ 5�AIN Ea>STEEl Wood Council NDS for Wood Construction. a, :. '.. 2X Fes:. q^ f - 2i( 744.00 i I 0 / r i EXPLCOED ASSEMBLY 2� v '. �-' SPLICE SOOT X OW'cN$(ESNS b N tf sa au ZflC ' , fi � it,_'-g4 '.�, PRODUCT APPROV EDa ms'�od•W21-D]2_.03 �p '=�*t NO-735`CL Noa ,. Ft'- - .,$,• - m 02/1712022 w� 'i ,. "'• �^rSlArEDF PL 9ATF' iPES-GNATURE: I 't�S, LORi�N 0 rf�tAi'9:I _- 01 4}2022 t SHINGLE ROOF MOUNT DETAIL & DATA K S nscnlP Ian. - - SFaCc' FOOT X KIT ASSEM$L'Y „ N.T.S. DOCUMENT CONTROL DATE CAD OC ENGINEER CONTACT INFORMATION ENGINEERING STAMP CONTRACTOR CONTACT INFORMATION CONTRACTOR LOGO CUSTOMER: ELIZABETH DAFFRON PROJECT ADDRESS: 39418 KENNEDY AVE ZEPHYRHILLS FL 33542 S O L A R P O Af E R PARCEL NUMBER: 12-26-21-0280-00000-0470 SHEET NAME: RACKING PLAN ISSUED FOR PERMIT 05-04-22 AO JC ENGIPARTNERS LLC C.A.32661 211 GIRALDA AVE CORAL GABLES, FL 33134 DESIGN@ENGIPARTNERS.COM 833 - 888 - 3644 Rafael A TITAN SOLAR POWER FL Gonzalez 12221 N US HIGHWAY 301 `Soto .. THONOTASASSA. FL 33592 2022.05.04 ,P 11:45:55 (813) 982 -9001 -04'00' #EC13008093 REV DESCRIPTION DATE GAD OC PROJECT ID: TSP122830 ENGINEER OF RECORD: NO RAFAELA GONZALEZ SOTO, PE SHEET TITLE: S-�+^S DATE: 05-03-22 ., 140n..411i , L26in ,odunng frame) (1F79 mrrK L045mm>t 32mm)-- ;i't 485Ibs,22.0 KgY co-, 0t3 m(3.1rI ltherrally 6jlasswMh arti-r,flactioir techoology 'a 6 a k aood eo al m,norr 4 22 Q AN f U te s.hr ILL s„,. I u, 2 09 3.98Ir 1-2e-226 x 0"09-0 /r n (_3 101f— 32-60 15-16mru)IP67, wi th hyiudss Uioaes _ 4rnm'Suarcable: .-)= 492 TA(1250 mrr)!, )� 49 n(1253M-) 6ubti Mr'A 1p53 POWERCLASS 385 390 395 400 405. 385 350 095 Qt,U 405._ ,.._ — .. .._..,w._ I. IAJ �104 11C, _.A 1117 i ,$.-..i F5j ". tr "'�.'r�,.,. r .. ,. J ✓] ._ 7�1`J n5 3 4�i. o C ,534 ,. .._ )" O a.3 J f 1L 7 + 1083 - - ...._._. it TII''IP 3636 aU 3568 37 3 ' 3 9 6P61$ftz Cu ✓) a _ _q [ 1:6 >199 _ 01- >- G 206 111­) Warranty QZi QCELLS ;) bay. _ ?90 9 J2 89 �a 9/ %Z SLOO c/ 1 a r _ 5 - HE 2 nlltllt _ __.. Q AN I UM DUO 7 Tcchno oc with zero gap cell layout ` rI 34 s9 81 a� 2 3r 4a boostsmodu,eefficiencyupto20,9h. e3=� cm c _ u �I , �r r _�rtl ro o r e a s -'a ,�fr rMOF Gi CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE F O ,w!E rt f _ _ P L r a Ca CELLS lathe fYs'solar r odule manufacturer o pass the rno t comprehen- sive quality programme In the industry* The new "Quality Controlled PV' of ' Al 91 _ 3f uorr a to i ! r t he independent certification icsf_ut TUV hernland_ _av 5,.-r ,r.r<IP vr:rPT « . _ e.3 ,EA..V_ `U.-W_A, ,a e Optimal yields, whatever the weatnE vf;th excelien: ow -light and temperature behaviorr ,,p "t- >s ,J1t-,'s .x ..s c`f„a.- ...�K."., ?:..,... comF,.r,� "COGP �...... b d secur 1 with A t ID Technology, Ant. PID _---- : g y ` gy. TEMPERATURE COEFFICIENTS bong -ten �I ec,.noro v", Hot -Spot Protect and Traceable Qu�ity Tra.Q" - _ _ __ a - <, u34 �i. ,, y (r'41 C34 ..,, .„<i+ ��. „ ,• „ -, UN"3r - 119tj ne 3 ,,C _ , °aHf . ATIN ,...-. ._ ,- High-tech aiummPROPER al ov frame eribied for T s FOR SY. tv3 r �� 1 high sooJi (54G0'e, and wind loads {4000Pe). _, - _ - - -- - _ lA C I- r3 U a5 t b { Inclusive 25/ear product warranty and 25-year - - linear performance warranty - sec 04 a tx i Y 0 1S:�`aN1 C EERs . ,E�+ P ,F K?t P AA 9 I r .M �.., ru ,.. 4 ,,, � .� .�. .{ire.•. ..s.a f 3 �o d� THE IDEAL SOLUTION FOR: ° ? E it 43 n:r 2 C _6561b,kq 4 �.a 32 "' - 1 -- - --- ^, ri t i .I Cal _ . .'dLA- . _- (. SUS rx a i>u i ,aa: e -- •. � — . c g 01 CE Lo H nwfi OCELLS A- - lnc. Engineered in Germany a,,+U Stx tr, p,,,,,le 1-1u. e, c 126 ua4 , :- 194a,48 �93Y6ti;� .� w via. �_,_ r�rNE9 r,A,p ti t T, e DOCUMENT CONTROL DATE CAD OC ENGINEER CONTACT INFORMATION iE6qP4EIjNG'tAMP CONTRACTOR CONTACT INFORMATION CONTRACTOR LOGO CUSTOMER: SHEET NAME: ISSUED FOR PERMIT os-o4sz ao Jc ENGIPARTNERS LI Rafael TITAN SOLAR POWER FL ELIZABETH DAFFRON �� MODULES DATA SHEET — _ �VI lJ t1 L_ REV DESCRIPTION DATE CAD DO PROJECT ADDRESS: C.A. 32661 Gonzalez 12221 N US HIGHWAY 301 Ilk I 255 GIRALDA AVE SOtO AN 39418 KENNEDY AVE CORAL GABLES, FL 33134 .r - THONOTASASSA, FL 33592 ZEPHYRHILLS FL 33542 PROJECT ID: ENGINEER OF RECORD: SHEET TITLE: 7. , -' - 2022-05.04 S D L A R P 0 W E €i pp ENG. RAFAEL A. GONZAL EZ SOTO. PE ---- DESIGN@ENGIPARTNERS.COM e 11:46:05 (813)9$2 -9001 PARCEL NUMBER: ----' TSPI Z2HJO DATE: ®-1 12-26-21-0280-00000-0470 os-oazz 833 - 388 - 3644-04'00' #EC13008093 MMIMZ��� I Specifically designed to work with SolarEdge inverters I Up to 25% more energy I Superior efficiency (99.5%) 1 Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading I Flexible system design for maximum space utilization solaredge.com I Fast installation with a single bolt I Next generation maintenance with module - level monitoring I Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Shutdown System (PVRSS) I Module -level voltage shutdown for installer and firefighter safety rl% Power Optimizer For North America P320 / P340 / P370 / P4047/_P_40_1_/k05 / P485 / P505 OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) �3 ehC,;fpul volt',r), P', PC;','0- uli­rn Zet STANDARD COMPLIANCE Z'j'.7 41- 1'lo j" qui J_ ;d 'fl, P 40, P ­Icyr, P 4(,01, p '11 -- --- --- --- - --- --- -- -- -- 60,.' UV, P­d, I 'A�';,, of t it Z' IV ......... . � dq, T -ey­md t,,d, -,f SA,Edg� T­,­�, 1,, �,N,,y. i Id Alt ,,,M . ...... .. l 101,1­6�. Ir" Sd,,'F­ 1�9, VIDTIMlZE BY SOLAREX� , , -A, RoHS f .aW C15 �O� I z t� 'h_" , 11"'tInterfek aPl EZ DOCUMENT CONTROL DATE CAD I QC I ENGINE ER CONTACT INFORMATION ENGINEERING STAMP CONTRACTOR CONTACT INFORMATION CONTRACTOR LOGO A k 11 T I TA N CUSTOMER: ELIZABETH DAFFRON --- PROJECT ADDRESS. 39418 KENNEDY AVE SHEET NAME: SMART MONITORING DATA SHEET ISSUED FOR PERMIT 05-04-22 AD I JC ENGIPARTNERS LLC C k32661 255 GIRALDA AVE Rafael A Gonzalez --Soto TITAN SOLAR POWER FL. 12221 N US HIGHWAY 301 REV DESCRIPTION DATE CADJQC PROJECT 10: ENGINEER OF RECORD: SHEET TITLE: CORAL GABLES, FL 33134 THONOTASASSA, FL 33592 ZEPHYRHIULS FL 33542 DESIGN@ENGIPARTNERS COM 11:46:16 (813) 982 -9001 S 0 L A R P it W E R TSP122830 NO RAFAEL A GONZALEZ SOTO, RE DATE: D-2 PARCEL NUMBER: _T_ 833 - 888 - 3644 - 04'00' #EC13008093 12-26-21-0280-00000-0470 05-0322 Single Phase Inverter with HD -Wave Technology for North America SE300OH-US / SE3800H-US / SE500OH-US / E6000H US/ j SE760OH-US / SE1000OH-US / SE1140OH-US Single Phase Inverter with HD -Wave Technology for North America SE300OH-US / SE380OH-US / SE5000H-US SE6000H-US/ SE760OH-US / SE1000OH-US / SE1140OH-US .: � ADDiFiONRi FEAFURES ,• � tad t'. x xt 6. „ rs ,a', � o r I 1UTPUT ^Ix{ _ ,., ��t ��( ',.9, Iry 4 ,. F I Cc I 0., ;^ ✓ fl - _ - u;`A' ? 11 ti -------- .— - _— _ ---- r STANDARD COMPLIANCE - _ '-. .. .- ... - t. A' J I L r.1 r - -..-...... tIJ ra V d INSTALLATION SPECIFICATIONS g8 �. A.1 > tr � 9 z 3 YPUT _ � n �s r How to Enable Consumption Monitoring By simply wiring current transformers through the inverter's existing AC conduits and connecting them to the service panel, homeowners will gain full insight into their household energy usage helping them to avoid high electricity bills Single phase inverter with Optimized installation with HD -Wave technology HD- wave technology and built-in RGM and 2 Specifically designed to work with power optimizers I UL1741 SA certified, for CPUC Rule 21 and compliance� z°� Service Panel consumption monitoring ' .gg Z S 0 TO y Record -breaking 99 % weighted efficiency I Small, lightweight, and easy to Install both '� ,tom , . " ' ' ' - " , oo, Grid ,. outdoors or indoors ' , i I Quick and easy inverter commissioning directly from , I rI a smartphone using the SclarEdge SetApp Built-in module -level monitoring s 4d cAT a61Q i y Fixed voltage inverter for longer strings y Optional Faster Instaliatlons with built in 8 ; L1N consumption metering (1 / accuracy) and I Integrated arc fault protection and rapid shutdown production revenue grade metering {0 5% accuracy, Sr for NEC 2014, NEC 2017 and NEC 2020 per article ANSI C12201 " � a p ACCU t w 690.11 and 690.12 _ e �r " a1;1' ,, ., s Iaiedye.cr-m s o I a / , a € OHS DOCUMENT CONTROL DATE ICADI GC. ENGINEER CONTACT INFORMATION ENGINEERING STAMP CONTRACTOR CONTACT INFORMATION CONTRACTOR LOGO CUSTOMER: UZABETH SAFFRON PROJECT ADDRESS: 39418 KENNEDY AVE (&T I TAN ZEPHYRHILLS FL 33542 s e L A a P O W E R PARCEL NUMBER: 12-26-21-0280-00000-0470 SHEET NAME: INVERTER T SHEET ISSUED FOR PERMIT 05- 4-22 AOIJC ENGIPARTNERS LLC Rafael A TITAN SOLAR POWER FL C.A. 32661 Gonzalez 12221 N US HIGHWAY 301 266 GIRALDA AVE CORAL GABLES, FL 33134 Soto THONOTASASSA, FL 33592 2022.05.04 DESIGN@ENGI PARTNERS.COM '11:46:26 (813)982-9001 - 888 - 3644-04'00' #EC13008093 REV DESCRIPTION DATE CAD OC PROJECT i0: q pn} TSP122830 rNGINEER OF RECORD SHEET TITLE: RAFAEL A GON ALEz solo. PE E:®—v833 3-22 —