HomeMy WebLinkAbout22-4194City of Zephyrhills
5335 Eighth Street
Zephyrhills, FL 33542
Phone: (813) 780-0020
Fax: (813) 780-0021
milwam
BGR-004194-2022
Issue Date: 05/31/2022
REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection, whichever is greater, for each subsequent reinspection.
Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies.
•a 11• ............. I•I z,r,•. • -- . i r T s.- .. - ..... . .
23131���
Complete Plans, Speccations add fee Must Accompany Application. All work shall be performed in
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CONTRACTOR SIGNATURE PE IT OFFICEV
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER i
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
Date Received Phone Contact for Permitting
Owner's Name Sixth Avenue LLC C/0 DUfi & Phelps, A oll &e Number
Owner's Address 917 W Washington MS 316 Chicago IL 6 607ownerPhoneNumber
Fee Simple Titleholder Name Owner Phone Number
Fee Simple Titleholder Address
JOB ADDRESS 39462 Tabetha Drive Unit 116 LOT#
SUBDIVISION PARCEL ID# 12-26-21-0028-00500-0000
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED e NEWCONSrRB ADD/ALT = SIGN DEMOLISH
INSTALL REPAIR
PROPOSED USE Q SFR COMM OTHER
TYPE OF CONSTRUCTION 0 BLOCK FRAME STEEL
DESCRIPTION OF WORK demo and legal disposal of SF mobile home
BUILDING SIZE I SQ FOOTAGE 9®0 HEIGHT
=BUILDING $5900.00 VALUATION OF TOTAL CONSTRUCTION
=ELECTRICAL 1$
PLUMBING $ '_....._._....__.._
MECHANICAL 1$�
=GAS 0 ROOFING
FINISHED FLOOR EL ONS
BUILDER
SIGNATURE
Addres
ELECTRICIAN
SIGNATURE
Address
PLUMBER
SIGNATURE
Address
MECHANICAL
SIGNATURE
Address
OTHER
SIGNATURE
Address
11IIIIII
RESIDENTIAL
COMMERCIAL
SIGN PERMIT
AMP SERVICE 0 PROGRESS ENERGY 0 W.R.E.C.
VALUATION OF MECHANICAL INSTALLATION $
SPECIALTY = OTHER (�
FLOOD ZONE AREA =YES NO
( �.Py'�, e Cf �(w✓� ,ntt��° p -;'°' REGISTERED
1706 E. Tr pry d"'ant City FL 33566
COMPANY
REGISTERED
I
COMPANY
REGISTERED
COMPANY
�a REGISTERED
�- --� COMPANY
REGISTERED
I/IIIIIIIIIIIIII11111/I111111
Johnson's Excavation & Services, Inc.
Y / N FEE -CUR -RE -I` Y / N
License# CBC059540
Y / N FEE CURREN
License # a
Y/ N FEE CURREN Y I N
License #
Y / N FEE CURREN _Y / N
License # �®
Y / N FEE CURREN I Y / N
License #^�
I I I I I III I I I I I I I I I I I I/ I I I I I I I
Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forays; R-O-W Permit for new construction,
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects
Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction.
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance
Attach (2) sets of Engineered Plans.
-PROPERTY SURVEY required for all NEW construction.
.
Directions:
Fill out application completely.
Owner & Contractor sign back of application, notarized
If over $2500, a Notice of Commencement is required. (A1C upgrades over $7500)
— Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences (PloUSurvey/Footage)
Driveways -Not over Counter if on public roadways -needs ROW
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions"
which may be more restrictive than County regulations, The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or
final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I
certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law —Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the "owner', I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the "owner" prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
Southwest Florida Water Management District -Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
Army Corps of Engineers -Seawalls, Docks, Navigable Waterways.
Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment,
Septic Tanks.
US Environmental Protection Agency -Asbestos abatement.
Federal Aviation Authority -Runways.
I understand that the following restrictions apply to the use of fill:
Use of fill is not allowed in Flood Zone'V'unless expressly permitted.
If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
If the fill material is to be used in Flood Zone "K in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension
may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate
justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned.
16-104 kIL"912 I ILIA 1 ..0
Notary Public
Commission No.
Commission
typed, printed
NT MAY RESULT IN YOUR
AIN FINANCING, CONSULT
rimed) before me this
.Johnson
me or has/have produced
as identification.
Ufflkf��X5 s ff I k7 ,t7l�
Ell QW
IN
I mm—Mmme I igimm,
INSTR#2022118027OR BK10621 PG1984 Page 1 of 1
05/26/2022 09:27 AM Rcpt: 2460878 Reo: 10.00 DS: 0.00 IT: 0.00
Nikki Alvarez-Sowles, Esq., Pasco County Clerk & Comptroller
Permit Numbor,
Mate of Rorlda, County NO =ICIE OF COMMENCEMENT
of
The undersignea harery give nojffh-jt�MPMVamont will be mode to certain real proporty, and in aomrdanoo
with Chaptw 713, n- 004 Stalifts, the followinp l*rmollon Is mvicled In this Nod o of Commencement.
11
Z
9
AcIdmss
4, Conftctor
15. Surety (, applicable, a copy
Xalephc�v Number 113��752-709�7
_Telephone Wuhiber�__
7, ftrsom - w , I , t - h1i , n . th I e Ir Side -of Florida desil kry owl nor up - on Wbom notice$ or other 400"monts MM
be servod as provided by Flodda StAbAoa,
Name-- 7alephone Number_ 'A
8, Inadtliftv to himself or horself, Owner doslonates the follomdag to Moolvo a CORYOM* L110nors
Notlov as proielded in §713.1�(I)(b), F1041da -SWIAWS.
_-Telephone Nurnber_
FlW'di" be! year ffm ft date (x
unless a different datt Is'spooffied)
SUSAN'— KOWAL
4s011ally Known JO R Produced ID
EXPIRES: October 12,2023
Type of ID Produced _-------�-
oFlorida Department of DEP Form 62-257.900(l)
lx Effective 10-12-08
ronmrio
Page 1 of 2
Enviental Potectn
Division of Air Resource Management
NOTICE OF DEMOLITION OR ASBESTOS RENOVATION
TYPE OF NOTICE (CHECK ONE ONLY): Z ORIGINAL [:] REVISED ❑ CANCELLATION El COURTESY
TYPE OF PROJECT (CHECK ONE ONLY): Z DEMOLITION El RENOVATION
IF DEMOLITION, IS IT AN ORDERED DEMOLITION? []YES M NO
IF RENOVATION:
IS IT AN EMERGENCY RENOVATION OPERATION? MYES [I NO
IS IT A PLANNED RENOVATION OPERATION? FIYES M NO
I. Facility Name Sixth Avenue LLC
Address 39462 Tabetha Dr
City Zephyrhills —State FL
Site Unit 116
Building Size 900
Zip 33542
Consultant Inspecting Site
County Pasco
Terracon
(Square Feet) #of Floors 1 Building Age in Years 50
Prior Use: ❑ School/College/University El Residence E] Small Business M Other
Present Use: ❑ School/College/University M Residence M Small Business M Other
II. Facility Owner Sixth Avenue LLC Phone ((813) 52-7097
Address 917 W. Wasington IVIS 316 C/o Duff & Phelps, A Kroll Business
City Chicago State IL Zip 60607
Ill. Contractor's Name JOHNSON'S EXCAVATION& SERVICES, INC. - DONATHAN A JOHNSON Phone ((813) ,�52-7097
Address 1706 E Trapnell Rd
City. Plant City State FL Zip 33666
Is the contractor exempt from licensure under section 469.002(4), F.S.? E] YES ❑ NO
IV. Scheduled Dates: (Notice must be postmarked 10 working days before the project start date)
Asbestos Removal (mm/dd/yy) Start: Finish: — Demo/Renovation (mm/dd/yy) Start: 06/13/2022 Finish: 06/30/2022
V. Description of planned demolition or renovation work to be performed and methods to be employed, including demolition or renovation techniques
to be used and description of affected facility components, demo done by excavator and legal disposal of removed product by roll off
Procedures to be Used (Check All That Apply):
VI. Procedures for Unexpected RACM: Stop, Contain area, call environmental compliance services
VII. Asbestos Waste Transporter: Name JOHNSON'S EXCAVATION & SERVICES, INC. - DONATHAN A JOHNSON Phone ((813) 52-7097
Address 1706 E Trapnell Rd
City Plant City — State FL —Zip 33566 4936
VIII. Waste Disposal Site: Name ENTERPRISE LF & RECYC (FKA SID LARKIN & SON, INC.) Class
Address 41111 Enterprise Rd
City Dade City State FL Zip 33525 1589
IX RACM or ACM: Procedure, including analytical methods, employed to detect the presence of RACM and Category I and 11 nonfriable ACM.
physical assessment, sampling and analysis for suspect material
Amount of RACM or ACM* X. Fee Invoice Will Be Sent to Address in Block Below: (Print or Type)
0 square feet surfacing material
0 linear feet pipe
0 cubic feet of RACM off facility components
0 square feet cementitious material
0 square feet resilient flooring
0 square feet asphalt roofing
*Identify and describe surfacing material and other materials as applicable:
0
Other materials or facility components description:. (R)ACM to remain in place during demolition:
I certify that the above information is correct and that an individual trained in the provisions of this regulation (40 CFR Part 61, Subpart M) will be on -site
during the demolition or renovation and evidence that the required training has been accomplished by this person will be available for inspection during
normal business hours.
Donathan Johnson 05/23/2022
(Print Name of Owner/Operator) (Date)
05/23/2022
(Signature of Owner/Operator) (Date)
Mr. Nicholas Eilerman
Environmental & Compliance Project Manager
Realty Systems, Inc.
c/o Equity LifeStyle Properties
5100 W. Lemon Street
Tampa, Florida 33609
Re: Pre -Demolition Asbestos Survey
6 1h Ave MHP (Loc. #7800)
Unit 116
39345 6th Ave
Zephyrhills, FL 33540
Project No. H4217407
Dear Mr. Eilerman:
W,
r-: (813) 282-5973
E: nicholas eiIerman15__u;41tff--'1, le.com
Terracon conducted pre -demolition asbestos sampling associated with the planned demolition of
Unit 116. As requested through a task order, dated October 25, 2021, our scope of service
included the collection of bulk samples of suspect asbestos -containing materials (ACM). Samples
were submitted to an accredited laboratory for analytical analysis and reporting of results.
F*ksbestos sampling was performed on November 11, 2021 by Mr. Karl Kologiski, an AHE -
accredited building inspector. Twenty-six (26) bulk samples were collected from thirteen (1
homogeneous areas of suspect ACM. Bulk samples were submitted under chain of custody 01
Cates Laboratories, Inc. for analysis by polarized light microscopy with dispersion staini
techniques per EPA/600/R-93/116. I
Based on the results of laboratory analysis of the designated, suspect materials, the followin*
materials were found to contain asbestos:
-A NESHAPOSHA Work
Location SaMpje!� Description Asbestos Classification Est Quantity Class
Kitchen F1-5 12" Square Pattern 65%
Bathroom F1-6 Vinyl Shoot Flooring 2 nd Layer Non -Friable Cat 1 200 S.F Work Class 11
r_ior_T rim 60 S.F
Windows - E11-111 Gray Sealant Gasket 10% Non -Friable Cat 11 2 Entry Doors, Work Class 11
Doors frames E1-12 Under Trim 11 Windows
Original Roof 112-19 White/Tan 5% I Non -Friable Cat 1 500 S.F Work Class 11
R2-20 Roof Coating
Roof Drip Rail Gray Sealant Gasket 3 OSI. F
Cap R3-22 Under Trim 10% Non -Friable Cat 11 1 Work Class 11
Terracon Consultants, Inc. 5463 West Waters Avenue, Suite 830 Tampa, Florida 33634
P [8131221 0050 F [8131221 0051 terracon.com
Pre -Demolition Asbestos Survey
SmAve K0HP(Loc#78OO)Unit 11Gm Zephyrhi|ls.F|ohda
s.t=Square Feet
[)ChrysotileAobesta
(l Estimated quantities are to be verified by contractor prior to disturbance and not to be relied upon
for bidding urnotification purposes.
|naddition tOhaving the ACM properly abated, vverecommend contacting your local regu
for confirmation of their pre -demolition requirements and to maintain a copy of the survey onsite.
Asbestos sampling was conducted |Oamanner consistent with the level of care and skill ordinarily
exercised by members ofthe profession currently practicing under similar conditions in the same
locale. The naauU3, findings, condueionS, and recommendations expressed in this report are
based On conditions observed during the S80p|iOg event If other suspect A(3WY are identified,
please CODtaotT8rrgcoO S0that vve can aSs8SS the implications. This letter report has been
prepared on behalf of and exclusively for use and reliance by Realty Systems, Inc. This report is
not a bidding document. Contractors or consultants reviewing this Smrnp|inQ report must draw
their own conclusions regarding further investigation or remediation deemed necessary. Tern3coD
does not warrant the work of regulatory agencies, laboratories or other third parties supplying
infOrnlaUOO, vvh|oh may have been used in the preparation of this report. No vvarn3ntv. expressed
or implied, is made.
Tenac0n appreciates the opportunity to provide this service to R88Uv Systems, Inc. If you have
any questions regarding this asbestos survey r8pOrt, please contact the undersigned at /813\
221-OO5U.
Sincerely,
Florida Asbestos Business License Number ZA-337
Prepared by:
Karl Kologiski
AHERA Building Inspecti
Attachments: Analytical Results
Reviewed by.
Tom Holley, C] H.
Florida Licensed Asbestos Consultant AX75
Authorized Project Reviewer
PLM REPORT SUMMARY
Cates Laboratories NVLAP Lab No. 200569-0
1339 Motor Circle TDSHS License No. 30-0287
Dallas, Texas 75207 (214) 920-5006
Client: Terracon Lab Job No.: PLM-27689
Proj ect (Line 1): 6th Ave. M H P, U n it 116 Set No.: 40426
Project (Line 2): 39345 6th Ave., Zephyrhills, Florida Report Date: 11/16/2021
Project No: H4217407 Sample Date: 11/11/2021
Identification: Asbestos, Bulk Sample Analysis
Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS)
EPA Method 600/R-93/116 Pagel of`3
On 11/12/2021, twenty-six (26) bulk samples were submitted by Mr. Karl Kologiski of Terracon for asbestos analysis by PLM/DS.
Copies of the lab data sheets are attached, additional information may be 'found therein. The results are summarized below:
Lab
Client
Sample Description/Location
Asbestos Content
Sample No.
Field I.D.
CL966419
Cl-I
Textured Ceiling Panel - Living Room
None Detected
CL966420
C 1-2
Textured Ceiling Panel - Kitchen
None Detected
CL966421
WI-3
Wall Panels - Kitchen
None Detected - Paper
None Detected - Wallboard Material
CL966422
WI-4
Wall Panels - Hallway
None Detected - Paper
None Detected - Wallboard Material
CL966423
FI-5
12" White Square Pattern VFT - Kitchen
None Detected - Floor Tile
None Detected - Yellow Mastic
None Detected - Sheet Flooring
65% Chrysotile - Fibrous Backing
CL966424
FI-6
12" White Square Pattern VFT - Bathroom
Not Analyzed - Positive Stop
CL966425
F2-7
12" White Diamond Pattern VFT- Kitchen Cabinets
None Detected - Floor Tile
None Detected - Clear Adhesive
CL966426
F2-8
12" White Diamond Pattern VFT - Front Steps
None Detected - Floor Tile
None Detected - Clear Adhesive
CL966427
MI-9
Interior Caulking - Bathroom
None Detected
CL966428
MI-10
Interior Caulking - Bathroom
None Detected
CL966429
EXI-11
Grey Gasket Material - Entry Door Frame
10% Chrysotile
CL966430
EXI-12
Grey Gasket Material - Side Window
Not Analyzed - Positive Stop
CL966431
EX2-13
Black Spray -On Sealant - Porch Ceiling
None Detected
CL966432
EX2-14
Black Spray -On Sealant - Porch Ceiling
None Detected
CL966433
EX3-15
Black, White Caulking - Porch Roof, Wall Joint
None Detected - Black Sealant
None Detected - Caulking
CL966434
EX3-16
Black, White Caulking - Porch Roof, Wall Joint
None Detected - Caulking
These samples were analyzed by layers. The overall percent asbestos for the sample is reported when relevant. The EPA considers a material to be asbestos containing
only if it contains greater than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing
Materials (RACM) — materials that are friable or may become friable — be further analyzed by point counting when the results indicate less than ten percent asbestos by
CVAE. CatesLab utilizes CVAE on a routine basis and does not include point counting unless specifically requested by the client. The results may not be reproduced
except in ful I.
PLM REPORT SUMMARY
Cates tones NVLAP Lab No. 200569-0
SO 1339 Motor Circle W TDSHS License No. 30-0287
Dallas, Texas 75207 (214) 920-5006
Client: Terracon Lab Job No.: PLM-27689
Project (Line 1): 6th Ave. MHP, Unit 116 Set No.: 40426
Project (Line 2): 39345 6th Ave., Zephyrhills, Florida Report Date: 11/16/2021
Project No: H4217407 Sample Date: 11/11/2021
Identification: Asbestos, Bulk Sample Analysis
Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS)
EPA Method 600/R-93/116 Page 2 of 3
On 11/12/2021, twenty-six (26) bulk samples were submitted by Mr. Karl Kologiski of Terracon for asbestos analysis by PLM/DS.
Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below:
Lab
Client
Sample Description/Location
Asbestos Content
Sample No.
Field I.D.
CL966435
RI-17
Roof Coating, Black, White - New Roof Overlay
None Detected - Surfacing Material
None Detected - Roofing Tar
CL966436
RI-18
Roof Coating, Black, White - New Roof Overlay
None Detected - Surfacing Material
None Detected - Roofing Tar
CL966437
R2-19
Roof Coating, White/Tan - Original Roof Deck
None Detected - White Coating
5% Chrysotile - Silver Paint
CL966438
R2-20
Roof Coating, White/Tan - Original Roof Deck
Not Analyzed - Positive Stop
CL966439
R3-21
Roof Seam Gasket, Grey - Roof Drip Rail
10% Chrysotile
CL966440
R3-22
Roof Seam Gasket, Grey - Roof Drip Rail
Not Analyzed - Positive Stop
CL966441
EX4-23
Concrete - Porch Slab
None Detected
CL966442
EX4-24
Concrete - Carport
None Detected
CL966443
EX5-25
Brick & Mortar - Planter Box
None Detected - Brick
None Detected - Mortar
CL966444
EX5-26
Brick & Mortar - Crawlspace Barrier
None Detected - Brick
None Detected - Mortar
These samples were analyzed by layers. The overall percent asbestos for the sample is reported when relevant. The EPA considers a material to be asbestos containing
only if it contains greater than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing
Materials (RACM) — materials that are friable or may become friable — be further analyzed by point counting when the results indicate less than ten percent asbestos by
CVAE. CatesLab utilizes CVAE on a routine basis and does not include point counting unless specifically requested by the client. The results may not be reproduced
except in full.
49 Cates Laboratories
1339 Motor Circle
Dallas, Texas 75207 (214) 920-5006
Client: Terracon
Project (Line 1): 6th Ave. MHP, Unit 116
Project (Line 2): 39345 6th Ave., Zephyrhills, Florida
Project No: H4217407
Identification: Asbestos, Bulk Sample Analysis
Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS)
EPA Method 600/R-93/116
On I I / 12/202 1, twenty-six (26) bulk samples were submitted by Mr. Karl Kologiski of Terracon for asbestos analysis by PLM/DS.
Copies of the lab data sheets are attached, additional information may be found therein.
NVLAP Lab No. 200569-0
TDSHS License No. 30-0287
Lab Job No.: PLM-27689
Set No.: 40426
Report Date: 11/16/2021
Sample Date: 11 /11 /2021
Page 3 of 3
The samples were analyzed in general accordance with the procedures outlined in the Method for the
Determination of Asbestos in Bulk Building Materials, EPA/600/R-93/116 or the U.S. Environmental
Protection Agency EPA 40 CFR Appendix E to Subpart E of Part 763, Interim Method of the Determination of
Asbestos in Bulk Insulation Samples, by polarized light microscopy. The results of each bulk sample relate
only to the material tested and the results shall not be used by the client to claim product certification, approval,
or endorsement by NVLAP, NIST, or any agency of the Federal Government.
Specific questions concerning bulk sample results shall be directed to the Laboratory Director.
Analyst: Kathy Schosek
Laboratory Director: John R. Cates, P.G.
Approved Signatory:
A
NVLAP LAB CODE 200569-0