Loading...
HomeMy WebLinkAbout22-422614 ty of Zephyrhill 5335 Eighth Street Zephyrhills, FL 33542 Phone: (813) 780-0020 Fax: (813) 780-0021 1 1111! MIMI 11!11!11111! 111 !1 11 1 11 1 !I! I I R I I I I I I F III Iff li I! 1 1! 1 BAR-00422 Issue Date: 07/1212022 Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. ---------- 112 CONT:b-: PE IT OFFICE z PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED 813480-0020 City of Zephyrhills Permit Application 1-ax-813-780-0021 Building Department Dateq;ived Phone Contact for Permitting �t Owner's Name Owner Phone Number (;21� A 3 1124— Owner's Address Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 9) C LOT # SUBDIVISION PARCEL to# IOBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD/AILT SIGN DEMOLISH El INSTALL REPAIR PROPOSED USE SFR COMM OTHER TYPE OF CONSTRUCTION BLOCK FRAME STEEL DESCRIPTION OF WORK BUILDING SIZE SCI FOOTAGE = HEIGHT [:= BUILDING L�� ELECTRICAL 1$ =PLUMBING =MECHANICAL =GAS ROOFING = FINISHED FLOOR ELEVATIONS E== VALUATION OF TOTAL CONSTRUCTION AMP SERVICE PROGRESS ENPRGY VALUATION OF MECHANICAL INSTALLATION SPECIALTY = OTHER FLOOD ZONE AREA =YES NO BUILDER COMPANY VV. R. E, C. c, c_j CUO "s SIGNATURE 4 a REGISTERED Address License # ELu. YEN COMPANY 1 1 V C-4yI! E E REGISTERED L FEE. C RREN Y/N _X_LN _J Address License# PLUMBER COMPANY E �;l �cl SIGNATURE REGISTERED N FEE � R R E N Y /��� Address License# MECHANICAL COMPANY E ;;;FEP�G.RRIII SIGNATURE REGISTERED Address License # OTHER COMPANY E ;;�IEICIRII�EN SIGNATURE REGISTERED I N�� Address Lrcense# itliatittillottistatistitillitilliffillittlitititttfttlllltltttlttli� RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans: (1) set of Energy Forms; R-O-W Pen -nit for new construction, Minimum ten H 0) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. —'PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely, Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (A/C upgrades over $7500) — Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage) Driveways -Not over Counter if on public roadways -needs ROW myr sponsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District -Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses, - Army Corps of Engineers -Seawalls, Docks, Navigable Waterways, - Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency -Asbestos abatement. - Federal Aviation Authority -Runways, I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone 'V" unless expressly permitted. - If the fill material is to be used in Flood Zone 'A", it is understood that a drainage plan addressing a . compensating volume" will be submitted at time of permitting which is prepared by a pr ssional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall, If fill material is to be used in any area, I certify that use of such fill will not adversely a act a jacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permltj�sued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an eingineered drainage plan is required. 110M ®r• 14 1 inva i .y1111ni jOjjA , '01 111WHIN ILI K211 Y— WE JACQUEUM, 80GES Commission # GG2, 76457 NotarylublicLary Public �emMb,-( 'a Name of Notary typed, printed or stamped INSTR#2022117121 OR BK PG3223 Page 1 of 1 05/25/2022 10:56 AM Ropt: 2460379 Rec: 10,00 DS: 0.00 IT: 0.00 Nikki Alvarez-Sowles, Esq., Pasco County Clerk & Comptroller Permit No. Parcel ID No A - 4 4- 11 w V% J 0 — 4),o— 1 State of County of THE UNDERSIGNED hereby gives notice that improvement will be mane to certain real property, and In accordance with Chapter 713. Florida Statutes, the totiowing information Is provided In this Notice of Commencement: 1. Description of Property: Parcel Identification No. Street Address:, 2. General Description of Improvement 3. Owner Information or Leases Information if the Lessee contracted for the improvement: Address State IrRarast in Property; Name of Fee Simple Titleholder: (if different from Owner fisted above) * ,...... Address. City Sdato * d 4. Contractor: Name Address City. State Contractor's Telephone No.: 5. Surety: Name * a' Address City Amount of Bond: $ Telephone No.: .¢. 8. Lender. Name Address City State Lender's Telephone No.: gt 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)ja)(7), Florida Statutes:. ty,} Name. va a> 0 a E Address City State 0 � Fo Telephone Number of Designated Parson: 8, In addition to himself, the owner designates of .. " to race" a copy of the Lienor's Notice as provided in Section 713.13(1 Kb), Florida Statutes. Telephone Number of Person or Entity Designated try Owner. 9. Expiration date of Notice of Commencement (the expiration date may not be before the completion of construction and final payment to the -. Q Q 0 contractor, but will be one year from the date of recording unless a different data Is specifred). ,0= p WARNING TO OWNER; ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER PART SECTION .. d1 co 713, 1, 713,13, FLORIDA STATUTES, RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY, A NOTICE OF COMMENCEMENT AND CAN MUST BE 11J. ct co q 0 0 0 E RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION; IF YOU INTEND TO OBTAIN FINANCING, WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. CONSULT p h tJ CJ �C Under penalty o4 perjury, 1 declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the treat rt' 0 gry ;d„ q1 $ of my knowledge and begot. STATE OF FLORIDA C- M COUNTY OF PASCO Signs of Otvmor or Lea , ew Owner's or Lessee`s Authorized..... Of r0ractor7PartnertManager Signatory's T flW0ffr- The foregoing Instrument was acknoMedged before me thay of , 20 by '" as (type of authority, e.g., officer, trustee, attorney in fact) for (na on behalf of om "" m .ant was o acuted). Personally Known C QR Produce Identification Notary Sig ura Type of Identification Produced Name (Print),,,,, wpdata@cs)noticeC ommencoment-pct}83Q48 z DESIGN CRITERIA: APPLICABLE CODES, REGULATIONS & STANDARDS 1. THE 2020 FLORIDA BUILDING CODE, SPECIFICALLY CHAPTER 16 STRUCTURAL DESIGN, CHAPTER 20 ALUMINUM & CH. 23 WOOD, 2. AA ASM 35 & SPECIFICATIONS FOR ALUMINUM STRUCTURES, PART 1-A OF THE ALUMINUM DESIGN MANUAL PREPARED BY THE ALUMINUM ASSOCIATION, INC, WASHINGTON D.C. 2005 ED, 3. ASCE 7-16 & SE17 4. NDS NATIONAL DESIGN SPECIFICATION FOR WOOD. 5, AC1318 CONCRETE REFERENCE MANUAL. WIND LOADS 1. BUILDING OCCUPANCY CATEGORY, PARAGRAPH 1604.5 & TABLE 1604.5: RISK CATEGORY 1, 2. BASIC WIND SPEED, TABLE 1609C, STATE OF FLORIDA DEBRIS REGION & BASIC WIND SPEED, PARAGRAPH 1609.3.1 & TABLE 1609.3.1 EQUIVALENT BASIC WIND SPEED: 130 MPH EXPOSURE CATEGORY, PARAGRAPH 1609.4.3: C 3. WIND LOADS PER FBC TABLE 2002.4 (MWFRS) VULT = 130 MPH & EXPOSURE = C FOR 20 X 20 X 0.013' MESH SCREEN HORIZONTAL PRESSURES ON WINDWARD SURFACES = 32 PSF HORIZONTAL PRESSURES ON LEEWARD SURFACES = 26 PSF VERTICAL PRESSURES ON SCREEN SURFACES = 9 PSF VERTICAL PRESSURES ON SOLID SURFACES = 27 PSF FOR 18 X 14 X 0.013" MESH SCREEN, APPLIED FACTOR = :88 FOR ALLOWABLE STRESS DESIGN, APPLIED FACTOR = 6 FOUNDATION DESIGN FOOTING SIZE EXISTING CONCRETE SLAB. NO ADDITIONAL FOOTING OR FOUNDATION SYSTEM IS REQUIRED BY THE PROPOSED CONSTRUCTION IF A MINIMUM 4" CONCRETE SLAB IS PROVIDED IN SOUND CONDITION, FREE FROM STRUCTURAL CRACKING, SPALLING & OTHER DETERIORATION. EXISTING FOUNDATION/FOOTING UNDER CONCRETE SLAB MINIMUM 8"x8" W/ (1) #5 BAR TO BE VERIFIED BY CONTRACTOR, SEE TYPICAL FOOTING DETAILS FOR NEW FOOTING DESIGN MINIMUM REQUIREMENTS. MISCELLANEOUS 1, SCREENED ENCLOSURES CONTAINING SWIMMING POOLS SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF FBC R4501.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS, 2, ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME, IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPARATE 4TH WALL SUPPORT SYSTEM IS SO TO BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. FASTENER SPECIFICATIONS 1. FASTENERS ARE REQUIRED TO BE SAE GRADE 2 OR BETTER ZINC PLATED. (CONCRETE ANCHORS ARE TO BE TAPCONS OR BETTER, INSTALLED TO MFG. SPECIFICATIONS) 2. IT IS THE OWNERS RESPONSIBILITY TO MAINTAIN THE SCREENS, FASTENERS AND SCREENS TO MANUFACTURING SPECIFICATIONS, 3, WHERE WOOD DECK IS PRESENT USE 1 /4" X 3-1/2" GALV. LAG SCREWS IN LIEU OF MASONRY ANCHORS, UNLESS OTHERWISE SPECIFIED, 4, 1"X2" NON STRUCTURAL MEMBERS ATTACHED TO HOST A, FOR MASONRY/CONCRETE APPLICATION USE GALVANIZED 1 /4" X 2-3/4" TAPCONS OR EQUAL AT 24' O.C. AND 6" FROM ENDS B. FOR WOOD APPLICATION USE # 14 X 2-3/4" WOOD SCREW AT 24' O.C. AND 6" FROM ENDS. C. FOR ALUMINUM APPLICATION USE # 10 X 1-1 /2" SMS OR TEK SCREW AT 24" O.C, AND 6" FROM ENDS D. WHERE I"X2" INSTALLED THROUGHOUT AN "OPEN VIEW' SPACING SHALL BE REDUCED TO 18" O.C. AND 6" FROM ENDS RESPONSIBILITIES 1. ALL SITE WORK SHALL BE PERFORMED BY A LICENSED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDANANCES, AND THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES. 2. FOR FASTENERS WHICH ARE NOT VISIBLE AFTER INSTALLATION, THE CONTRACTOR SHALL VERIFY AND ENSURE INSTALLATION HAS BEEN ACCOMPLISHED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS AND IN ACCORDANCE WITH THE ATTACHED DETAILS. 3, FOR"PICTURE WINDOW" MODIFICATION TO EXISTING SCREEN ENCLOSURES, ALL OTHER "EXISTING SCREEN ENCLOSURE" FEATURES ARE TO MEET THE TYPICAL DETAILS AS PROVIDED IN THESE DETAILS. CONTRACTOR IS TO VERIFY & ASSURE EXISTING SCREEN ENCLOSURE 15 STRUCTURALLY SOUND. 4, CONTRACTOR TO PROVIDE NOA'S & INSTALL ALL MATERIALS AS PER MANUFACTURER'S SPECIFICATIONS, 5, INTEGRITY OF EXISTING/ HOST STRUCTURE SHALL NOT BE COMPROMISED WITH THE ATTACHMENT OF THE PROPOSED STRUCTURE, SHEET NO. DRAWING INDEX -- - ---.-. --. S/01 GENERAL DOGES S/02 PLAN/ ELEVATIONS S/03 DETAILS I S/04 DETAILS ------------ ALL WORMSHALL Cam}MP ,f' W, ` R v�A�,,LING "ODES FLORIDA BUILDING CODE.,NiMrJONAL ELECTRIC CODE, rati te N CES !F 02=1011MMAN fEmEafflarmlEl ALUMINUM MEMBERS DIMENSIONS HOLLOW SECTIONS 2 x 2: Z x2`x0.044" 2 x 3: Z x3x0.050" 2 x 4: Z x4x0.050' 2 x 5: 2" x5` x0.059 OPEN BACK SECTIONS 1 x2: 1"x2"x0,044" 1 x 3: 1 "x3" x0.045" SNAP SECTIONS 2 x 2 SNAP: 2" x2" x0.045" 2 x 3 SNAP: Z x3" x0.050" 2 x 4 SNAP: 2" x4"x0.045" SELF MATING (SMB) 2 x 4 SMB: 2" x4"x0.044"x0,100" 2 x 5 SMB: 2"x5'x0.050"x0.100" 2 x 6 SMB: 2 x6'x0,050" x0,129' 2 x 7 SMB: 2"x7'x0.057x0.120" 2 x 8 SMB: 2"x8" x0.072"x0.124" 2 x 9 SMB: Z x9" x0.082"x0.124" 2 x 10 SMB: Z'xI0'x0.092"x0.398" o LL ` O t ,° o 4_1- X o _ ; U z =C /r OUSE MALL 1X2 I ®�D _c 2X3 X X X 1X2 81 911 RESIDENCE ---1 OST 12" cQj[flFASCIA MOUNT1 3" X °024" X 1LB COMPOSITE PANELS t L 3003-1--1154 C 1f4"-14 SLOPE (MIN.) (FL°# 7561.1-R5) 2X4SMB X 244-W i. _ x x x 00 c �I _i f 2X2 TYP. 1X2 TYP. ALUMINUM SPECIFICATIONS 1. ALUMINUM EXTRUSIONS SHALL BE 6005 T5 ALLOY UNLESS OTHERWISE NOTED. 2. ALL SELF MATING BEAM SECTIONS ARE TO BE STITCHED WITH # 12 SCREWS 6" FROM ENDS & 24" CENTER TO CENTER. # 10 SCREW 6'FROM ENDS & 12" CENTER TO CENETER. 3. THE MINIMUM NORMAL THICKNESS OF PROTECTOR PANELS (KICKPLATES) SHALL BE AN INDUSTRY STANDARD OF 0 024 INCHES. 4. VINYL AND ACRYLIC PANELS SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 MPH PER FBC. 5. SCREEN MATERIAL SHALL BE 18/14 SCREEN UNLESS APPROVED BY FLORIDA ENGINEERING LLC. 6, 1 "X2" & i "X3" NON STRUCTURAL MEMBERS MAY BE USED INTERCHANGEABLY, 7. DOOR LOCATION MAY BE DETERMINED/ RELOCATED BY CONTRACTOR IN THE FIELD, 8. INSULATED PANEL OVERHANG PER PRODUCT APPROVAL 36" (MAX.) AT FRONT, 25% OF LAST PANEL WIDTH ALONG SIDES, TYP. ii___L2X6SMB X 9R-f 91-011 i 1�1111iIlkl#fFtJ/f! 4 .� Q i C)° co a LL tJ 0III ci CNJ 5 cn tc !!/tJftttl{flf4tit''��� L3 � HOUSE 1 lALL/l/// 3X3 POST OUSE WALL/,r --711X2 2X3 < 4 x C'J 1X2 1 024 FLASHING SEALED TO WALL (TYP-) ALL # 14XI /2'S.MLS, VIS INTEGRAL 3140 WASHER AND 0 C> NEOPRENE GASKET @ I Z'O.C_ TOP & BOTTOM. 0- IF CLEARANCE PROHIBITS INSTALLATION OF TOP 7 0 FASTENERS USE #l4x4'S.M,.S. W/ 1-114'0 FENDER C> WASHER AND NEOPRENE GASKET @ 12'O.C. {3} PER PAN FOR PANS EXTRUDED OR BRAKE -FORMED ROOF HEADER OR R RECEIVING CHANNEL (0.0421"MIN. THICKNESS) WITH MIN. I- I /2'BEARING LEG. HOST STRUCTURE 14 0 x 2- /2: LONG WOOD LAG SCREW OR MASONRY OR WOOD 114 0 x 2-i 14 LONG MASONRY ANCHORS @ 24'O.C. MAX. ROOF PANEL ATTACHMENT - MASONRY SCALE: N.T.S. EXISTINGRAFTER ORTRUSS # 1 4x 1 /Z'S,E4.& W1 INTEGRAL 0 c WASHER AND NEOPRENE GASKET3/4FO @ 12'O.C., TOP & BOTTOM L {311 PER PAN FOR PANS EXTRUDED OR BRAKE -FORMED ROOF HEADER OR RECEIVING CHANNEL f0.044'lA1N. THICKNESS) SECURE FASCIA TWITH MIN, 1-1/2"BEARING LEG, IEACH RAFTER TAIL AV � I 11 114 0 x 4' LONG PAN HEAD LAG SCREWS (1) 114" 0 A ZLAG SCREW 4 24'0.C. BEFORE ATTACHING REC. CHANNEL ENTIRE LENGTH OF RECEIVING CHANNEL ROOF PANEL ATTACHMENT - WOOD FRAME SCALE: N.T.S. ALUMINUM INTERNAL OR EXTERNAL RECEIVING CHANNEL wl(4) #10A.75' INTO GIRT OR PURLIN & (2) #1 4x.75' INTO BEAM OR UPRIGHT 11.062 ANGLE (4) #IOXI-1/2'SMS INTO CLIPS MAYBE USED SCREW BOSSES PURLIN MEMBER UPRIGHT, BEAM -SNAP, SELF MATING, OR HOLLOW DETAIL "C" - GIRT OR PURLIN TO BEAM OR POST DETAIL SCALE- NTS 1/6AnZ'x ANGLE --,/A---, SELF -MATING OR SNAP SECTION TYP_ 5032 H-32 ANGLE {2) - #12 SMS INTO COLUMN - F'xZO.B. BASE PLATE-TYP. I/4'MASONRY ANCHOR EACH ANGLE - EACH SIDE COL. 1-1/4'MIN. CONC. o HOREMBEDMENT AN I L 2-114* MiN. CONIC 2' MIN. INCREASE DISTANCE AZOR EMBEDMENT WHEN GREATER THAN 2)(4 SECONDARY ANGLE UPRIGHT IS USED 3000PSI CONC. SLAB/ FTG. 6x6-I0xI 0 WWM OR FIBERMESH SIDE VIEW I CT' MASONRY ANCHOR AT EACH ANGLE (2) - #12 SIMS �1/4"TAPCON XL (RED HEAD MFG. OR EQUAL) 2-1/4 MIN. CONIC. I 2 Rv I AS BASE ANCHOR EMBEDMENT 2 @ SLAB fBEYOND) SECONDARY ANGLE S— I 'A2'BASE PLATE ANCHORED TO CONIC wl 1/4'MASONRY ANCHOR 6" MAX EACH SIDE OF POST AND 24'O,C. MAX 1-1 /4" CONIC. EMBEDMENT TYR. 3000 PSI CONC. 6" I NOTE SLAB/ FIG. WHERE PAVERS ARE PRESENT USE 5/16" TAPCON XL REDHEAD MFG.) MASONRY 6x6-1 OR 10 WWM FRONT VIEW ANCHORS TO PENETRATE UNDERLYING OR FIBERMESH CONCRETE FOOTING 2-114" (MIN.) DETAIL "B" - 2"x4" OR LARGER SELF MATING UPRIGHT TO DECK DETAILS SCALE: NTS ANCHORING UPRIGHT TO FOUNDATION NOTES: I ,- IF PAVERS ARE PRESENT, CONCRETE ANCHORS SHALL PENETRATE INTO FOOTING 2-1/4" MIN, (TYP.) 2,- WHEN FASTENING TO WOOD USE 1/4!'GALV, LAG SCREW IN LIEU OF CONIC. ANCHORS AND ENSURE 2-1/4!'MIN, PENETRATION INTO STRUCTURAL FRAMING BENEATH (TYP,) 3,- NO SECONDARY ANGLE REQUIRED FOR 2X3 UPRIGHTS OR DOOR JAMBS. (ENSURE 2-1/4!'MASONRY ANCHOR EMBEDMENT @ UPRIGHT LOCATIONS TYP.) ROOF PER PLAN #I 4x4",5'or 7" S.M.S. wl'-114'0 FENDER WASHER AND NEO-PRENE GASKET @ 12'O.C. # 12 X 9116'WI 5/W NEO-WASHER (3) PER PAN FOR PANS COVER END OF PANEL 3'X 2" X,05a'MIN, (SEE PLAN) ROOF PANEL TO CARRIER BEAM CONNECTION SCALE: N.T.S. OPTION # I FASTEN TOP OF HEADER TO INTERSECTING MEMBER w/ (4) #10 SIMS {INTERNAL) 2" MIN, INTO SCREW BOSS OF INTERSECTING MEMBER EDGE BEAM PER PLAN OPTION #2 ALUMINUM INTERNAL OR EXTERNAL RECEIVING CHANNEL wl(4) # lOx.75' INTO COLUMN & (2) # l4x.75� COL. PER INTO EDGE BEAM ('0.062 ANGLE PLAN ii COL. PER PLAN ii ji CLIPS MAYBE USED) �II II )II it III II it II 2X3/ 2X4 COL. TO 2X3/ 2X4 EDGE BEAM CONNECTION SCALE: N.T.S. #14x4` S,M S, wl 1-1/4' 0 =ENDER WASHER AND NEO-PRVNE GASKET@ 12" C.C. AX2"X1,N` ANGLE ITT TO FIT - i W/ (3 111 A,, 7�EAIII LEG ANGLE CUT TO FIT #14x4` S.M.S, K 1-1/4" 0 FENDER WASHER EACH SIDE OF UPRIGHT ryp. AND NEO­' PRENE GASKET @ 24" O.C. A/012x"75'@ I" SPACING MAX. (4) PER LEG (MINTYE, .) EACH SIDE FOR NON-LOADBEARING WALLS ALTERNATELY CLIPS MAYBE USED UPRIGHT PER PLAN ALUMINUM IM"E'RNAL OR CRT. EPINAL RECEIVING CHANNEL A4) #10x.75' INTO GIRT OR PURLIN 1, (2) #14,75' INTO REAM OR UPRIGHT 0.062 ANGLE CLIPS MAYBE USED �NGt.E PEON I RED ONE 11.1 ON 11 AT CORNER AND DOOR OPEN INGS SEE UPRIGHT TO DECK 1/4' OW. rAPCON 6`FROM ENDS CONNECTION DETAIL 24" 0,C. MAX 1 1/4" EMBEDMENT INTO UNDERLYING CONC, SIDE WALL UPRIGHT PER PLAN (4) #10x2" EMS INTO SCREW BOSSES WHERE KICK PLATE IS INDICATED FASTEN AA 910 X 9/16" EMS 6' FROM, CORNERS 18" IN FIELD OR FASTEN WE ft8 A 9/16- SMS 2" FROM CORNERS 8" IN FIELD 1/4'D. TAD IAPGON 6" FROM ENS 24" O.C.MAX A1-1/4' ENABEDMEI'4I INTO UNDERLYING CONC. 0 IS) #10,,2'SMS INTO SCREW BOSS'SOR CLIPS MAY BE USED FOUNDATION PER PLAN SCREEN ROOM END WALL DETAIL SCALE: N.T.S. —CARRIER BEAM (SEE PAGE-2 FOR SIZE) (2) 3/8!" DIA. MACHINE BOLTS THRU CARRIER BEAM & POST Im CARRIER BEAM (SEE PAGE-2 FOR SIZE) 3/9DIA. MACHINE ,LTS THRU CARRIER xM & POST li c / a',. - _/ '-'/.v "' EO-PRENE GASKET 4 12' O.C, a/l 6" W/ 5/8:'NEOWASHER PAN FOR PANS COVER END OF PANEL CARRIER BEAM (SEE PAGE-2 FOR SIZE) 3/6'DIA. MACHINE LTS THRU CARRIER \M & POST PTiONAL EXTRUDED GUTTER IS (ACHED TO 3" INSULATED ROOF #1 2xl" 6" FROM ENDS 24'O.C. BEAM TO POST CONNECTION BEAM TO POST CONNECTION POST TO CARRIER BEAM OPTION #1 SCALE: N.T.S. OPTION #2 SCALE: N.T.S. CONNECTION SCALE: N.T.S. (4) 114" DIA. FAPCON THRU BOTTOM LEG OF ANGLE 2-114"fMINJ INTO UNDERLYING CONIC. (2) 3/9'.10A. MACHINE — BOLTS w/ WASHERS 3-3/4" FROM EDGE --- OF SLAB/ FTG. MAY USE (3) #1 2-14x] TEK TOP VIEW IN LIEU OF THRUBOLTS IS) 3/9DIA MACHINE BOLTS w/ WASHERS (4) 114CIA. TAPCON THRU BOTTOM LEG OF ANGLE 2- 1 /4" (MIN.) INTO UNDERLYING CONC (2) 3/9" DIA, LDT'S THRU BOTTOM LEG OF IS) 3/8" DIA. MACHINE ANGLE 2-1/4" (MIN) BOLTS WASHERS INTO UNDERLYING CONC. 0 I 2'FROM EDGE 3-3/4" FROM EDO OF SLAB/ FTG. OF SLAB/ FG. TOP VIEW (2) 3/8' DIA. MACHINE 3X3, POST PER PLAN BOLISW/VIJASHERS 3x3'POST (SEE PAGE-2 (2) 3/9'DIA. LOTS FOR SIZE) — Azx3l /a LENGTH) ANGLE THRU BOTTOM LEG OF ANGLE 2-1/4!'IMIN.) MAY USE (3) #1 2-14x I" TEK (I (INTERNAL) INTO UNDERLYING C CONC. IN LIEU OF THRUBOLTS 3"A3'x0.125 ANGLE 3000 PSI COLIC. 3000 PSI CONC. SLAB/ FTG. SLAB/ FTG. 6x6- I Ox 10 WWM 6x6-I0x10wWM OR FIBERMESH OR FIBERMESH FRONT VIEW 3"x3" POST CONNECTION DETAIL (INTERNAL BASE) SCALE: N.T.S. 2"X2X I /9` ANGLE W/ (4) - #12 SMIS INTO COLUMN 1) - 3/9" MASONRY ANCHOR EACH ANGLE W/ 2-1/4" EMBEDMENT EACH SIDE COL. TYP. 3-3/4" FROM EDGE OF SLAB/ FTG. 3'xa'POST (SEE SHEET-02 FOR SIZE) 2'X2"XI /8!'ANGLE W1 (4) - # 12 SMS INTO COLUMN (1) - 3/6" MASONRY ANCHOR EACH ANGLE W/ 2-1/4'EMBEDMENT EACH SIDE COL. TYP. 3000 PSI CONC. SLAB/ FTC. FRONT VIEW 6x6-1 Ox 10 WWM OR FIBERMESH YxY POST CONNECTION DETAIL colawom 2X2-X.125" ANGLE W/ #1 4x3/4'THRU ANGLE LEG INTO BEAM EA. SIDE TYP. SEE TABLE FOR QUANTITY C14 4:5 - CIAJI co LL 0 LLJ CL co 0 0 0 z 0 LU uj rl FASTENER NOTES: MAINTAIN I /Z'SEPARATION BETWEEN FASTENERS. MAINTAIN 3/9'MIN, FASTENER SEPARATION FROM EDGE. FASTENERS MAY BE STAGGERED TO ENSURE PROPER QUANTITY PERMITTED (PATTERN MAY APPEAR DIFFERENT FROM ILUSTRATION) BEAM TO WALL w/ I /9'APER LEG TO WALLNGLE TABLE Z'X2'X. I 25'ANGLE W/ (3) 114" X 2-1/4" TAPCONS @ 2'o.c. QUAN HTY/ SIZE BEAM I QUANTITY ANCHOR THRU ANGLE LEG INTO HOST WALL BEAM SIZE PER LEG TO TOP VIEW -------------- 2X4 (4) # 12 - (2) # 16 I (2) 1/4:'TA 2X5 (5) #12 - (3) #16 (2) 1/4" TAPCON BEAM f PER PLAN I (2X7SMB ILLUSTRATED) 2X6 (5) #12- (3) #16 (3) 1/4" TAPCON ZXZX,125ANGLE W1 2X7 (6) #14 - (4) #16 (3) 114" TAPCON # 14x3/4" THRU ANGLE LEG EA. SIDE TYP. 2X8 (7) # 14 - (4) # I 6t�(4) 1"/�4TAPCON INTO BEAM SEE TABLE FOR QUANTITY L 2X9 (8) #14- (5) #16 (4) 1/4'TAPCON ----------- ------- -- LI 2X2'X.I25'ANGLEW/ 2XI0 (9) # 14 - (6) # 16 (5) 1/4- TAPCON f3) 114'X 2-1 /4" TAPCONS @ 2'o.c. THRU ANGLE LEG INTO HOST WALL SIDE VIEW BEAM TO HOST WALL CONNECTION SCALE: N.T.S. 1'5x2* BASE PLATE E ANCHORED TO CONC W/ I/4'MASONRY ANCHOR 6' MAX EACH SIDE OF POST AND 24'O.C, MAX 1-1 14" CONC. EMBEDMENT TYP_ FOR WOOD APPLICATION IN LIEU OF MASONRY ANCHORS USE: I IN'X S'GALV. LAGS I 'A2'BASE PLATE ANCHORED TO CONC wl 1/4'MASONRY ANCHOR 6" MAX EACH SIDE OF POST AND 24" O.C. MAX 1-1/4" CONC. EMBEDMENT TYP. 2'X2'X I /6'ANGLE W/ (4) - # 12 SIMS INTO COLUMN (T) - 3/9" MASONRY ANCHOR EACH ANGLE W/2-1/4* EMBEDMENT EACH SIDE COL. TYP. I X2'BASE PLATE ANCHORED TO CONC wl 1/4!'MASONRY ANCHOR 6' MAX EACH SIDE OF POST AND 24"O.C. MAX 1-1/4!'CONC. EMBEDMENT TYP. 3-3/4" FROM EDGE - I I -- , 4 15 OF " I � -1 1 - I '.1 - _ I I ry FRONT VIEW 3X3 POST CONNECTION DETAIL SCALE: NTS ffl�� IN CORNER POST TOP VIEW 3X3 CORNER POST CONNECTION DETAI SCALE: NTS AS BUILT SURVEY (FI AU WITH SELECTIVE SPOT ELEVATIONS LOT 175 HIDDEN RIVER PHASE 2 1 PASCO COUNTY, FLORIDA. ;fin n� � t<s �« }?pn' v" ar E-00.0' = EXISTING GRADE PREPARES) FOR & CERTIFIED TO: LENNAR TITLE, INC. FORMERLY KNOWN AS CALATLANTIC TITLE, INC. NORTH AMERICAN TITLE INSURANCE CO. LENNAR MORTGAGE, LLC JONATHAN MITCHELL WAINWRIGHT AGUILERA PCP(P) RADIUS POINT N 85'13'36" W CD ........ . .... . 63.00' ... . LY70N HALL DRIVE (PRIVATE R/W VARIES) (TRACT B) �i m �G' • GO 5 FLOOD ZONE REVISED PER LETTER OF MAP REVISION CASE No.. 20-0A-2639A DATED: APRIL. 30, 2020 DESCRIPTION: LOT 175, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE 2", AS RECORDED IN PLAT BOOK 79, PAGES 102 THROUGH 110, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. gCfAMUS����111�ARINGGEARING3,00 5 22'3955 Oq N 22`5f'02" E 36'09'16" P&M SEC. 25 TWP. 26 S. RNG, 21 E. WEST BOUNDARY OF SUBJECT PLAT BEING N 00'23'02" E THIS SURVEY IS SUBJECT TO ANY FACTS THAT MAY BE DISCLOSED BY A FULL AND ACCURATE TITLE SEARCH. ALSO SUBJECT TO SETBACKS, � T j EASEMENTS AND RESTRICTIONS OF RECORD. UNDERGROUND FOOTER, STEM WALL, AND UNDERGROUND UTILITIES ARE NOT LOCATED OR o SHOWN. DO NOT SCALE THIS PRINT. DIMENSIONS AND NOTES TAKE PREFERENCE, STRUCTURE TIES SHOWN HEREON DENOTES MEASUREMENT FROM FORM BOARDS/FOUNDATION v TO PROPERTY LINE, PURPOSE OF SURVEY; TO OBTAIN HORIZONTAL AND/OR VERTICAL DIMENSIONAL DATA TO SHOW CONSTRUCTION IMPROVEMENTS. * = 10' PUBLIC UTILITY EASEMENT PLAT I LOT 176 BOUNDARY try �w (Ur N .— �O. (P&M) 110,00, h Aye W N; Cr1 g.3' Q ` PILOT 175 TRACT "C" DRAINAGE EASEMENT HIDDEN RIVER PHASE ONE A (PLAT BOOK 74, PAGES 101-121) LOWEST FLOOR ELEVATIONS: LIVING AREA: 73,70` GARAGE AREA: 73.15' ELEVATIONS REFERENCED TO NATIONAL GEODETIC VERTICAL DATUM OF 1929. MEAN SEA LEVEL= 00.00 FT, FLOOD HAZARD ZONE: "X" COMMUNITY PANEL NO. 12101 C 0458 F EFFECTIVE DATE: 09 26 2014 Square Feet: 8135.24 LENNAR HOMES (C) = CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, q= CENTERLINE, A/C= AIR CONDITIONER, ALF= ,ALUMINUM FENCE, APU= APPARENT PHYSICAL USE, BFE= BASE FLOOD ELEVATION, COV.= COVERED, CONC.= CONCRETE, C/S= CONCRETE SLAB, COR.= CORNER, CLF= CHAIN LINK FENCE, E/P= EDGE OF PAVEMENT, F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPIP= FOUND PINCHED IRON PIPE, MAS.- MASONRY, NCF= NO CORNER FOUND OR SET, OR- OFFICIAL RECORD BOOK, PB= PLATBOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR= SET 1/2" IRON ROD & CAP No.4493, SN&D= SET NAIL & DISK No.4493, S W SIDEWALK TBM= TEMPORARY BENCHMARK V F= VINYL FENCE W F= WOOD FENCE, WIT,= WITNESS TYP = TYPICAL Drawn By: _r_ "I� �C' �1��a ��• SMS I HEREBY CERTIFY THAT THIS SURVEY WAS MADE UNDER MY tT SURVEYORS AND MAPPERS RESPONSIBLE CHARGE AND MEETS THE APPLICABLE STANDARDS OF 911 WEST ST. PETERSBURG DRIVE Checker) By: PRACTICE FOR SURVEYS AS SET FORTH BY THE FLORIDA BOARD OF ONE OLDSMAR, FLORIDA 34677 JRB LAND SURVEYORS IN CHAPTER 5J-17,051 THROUGH 5J-17,053, µAY Scale: FLORIDA ADMINISTRATIVE CODE, PURSUANT TO SECTION 472.027 (813) 854-1276 FAX (813) 855-8370 1"=30' FLORIDA ST E S TUT NOT VALID WITHOUT ORIGINAL SIGNATURE Date: AND SEAL OF A FLORIDA LICENSED FINAL 4/14/21 DWB SIGNATURE ATE SURVEYOR AND MAPPER JOHN R. EACH Revisions: FORM BOARD TIE IN 12/29/20 RTM, FOUNDATION TIE IN 1/28/21 JBS FpRIDA _ EG. SURVEYOR No. 2984 _ LB#4493 PROFESSIONAL SURVEYOR & MAPPER No. 6986