Loading...
HomeMy WebLinkAbout22-4243City of Zephyrhills Phone: "": 0. 780-0021 � tt L I C-004243- 022 Issue Date: 06/10/2022 REINSPECTION i.4' Reinspection fees will comply local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent reinspection. Notice: In addition to the requirements of - be ♦ • - to this property that foundmay be in the publiccounty,♦ there may be •governmental federalentities such as water management, state agencies or • `; � 'M i i . 4 • " ;1 :...� k it .� s i l' ' ' .: 4 ! i 4 accordance with City Codes and Ordinances. N6"OCCUPANCY 13EFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SI RE PE IT OFFICE THOUT APPROVED INSPECTION "` NOTICE REQUIRED 813-780-0020 City of Zephyrhills (permit Application Building Department . Y: Fax•813-780-0021 , , t U Date Received 06/10/22 Phone Contact for Permitting (727 2 4 v 7218 Owner's Name Juan Manautou Owner Phone Number 813-469-3556 Owner's Address 6214 Silver Oaks Dr. Owner Phone Number Fee Simple Titleholder Name ^� Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 6214 Silver Oaks Cyr. Zephyrhills, FI 33542 LOT# 10 SUBDIVISION Siyer Oaks PARCEL ID# 03-26-21-012A-00000-0100 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD(ALT = SIGN DEMOLISH 11 INSTALL D REPAIR PROPOSED USE SFR COMM OTHER sma�Pa,�ls TYPE OF CONSTRUCTION BLOCK a FRAME STEEL DESCRIPTION OF WORK Installation of PV Solar panels. BUILDING SIZE So FOOTAGE HEIGHT ®� =BUILDING �� VALUATION OF TOTAL CONSTRUCTION ELECTRICAL $27 317.00 AMP SERVICE PROGRESS ENERGY W.R.E.C. PLUMBING 1$ 1 =MECHANICAL 1$ 1 VALUATION OF MECHANICAL INSTALLATION [GAS ROOFING u SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY SIGNATURE REGISTERED Y / N FEE CURREN Y ( N Address License # ELECTRICIAN f~ COMPANY Freedom Forever .... SIGNATURE REGISTERED Y / N FEE CURREN Y / N Address 010 51 st A E #111 Palmetto FI 34221 License # I FC13008056 PLUMBER COMPANY SIGNATURE REGISTERED Y (N �CURR.N Address License # MECHANICAL COMPANY SIGNATURE REGISTERED Y / N FEE CURREN Y / N Address License # 7 �T OTHER COMPANY SIGNATURE REGISTERED Y / N FEE CURREN Y ( N Address _ License #--� RESIDENTIAL Attach (2) Plot Plans: (2) sets of Building Plans, (1) set of Energy Forms, R-O-W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page, (1) set of Energy Forms, R-O-W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. —PROPERTY SURVEY required for all NEW construction. Directions. Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (A/C upgrades over $7500) — Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences (PloUSurvey/Footage) Driveways -Not over Counter if on public roadways..needs ROW 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions, UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County, TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" orfinal power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid poor to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" poor to commencement, CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction, I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. Southwest Florida Water Management District -Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers -Seawalls, Docks, Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency -Asbestos abatement. Federal Aviation Authority- Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone W" unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended of abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. FLORIDA JURAT (F,S. 117.03) OWNER OR AGENT Subscribed and sworn to (or affirmed) before me this _b Who is/are personally known to me or has/have produced as identification. Notary Public Commission No. Name of Notary typed, printed or stamped Subscribed and me this Cl as identification, k Notary Public CommissicNo. Name of Notary typed, printed or stamped RMSIERRA C GRAY Notary Public - State of Florida ",,,A Commission # HH 114656 my Comm. Expires Apr 6, 2025 Bonded through National Notary Assn. THIS INSTRUMENT PREPARED'BY: Name: Address: 2619consulate m,Ste Boo Orlando, FL 32819 PhOTICE OF COMMENCEMENT Perrrait Number Parcel ID Number: 03-26-21-012A-00000-0 100 The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes 1,1e following information is provided in this Notice of Commencement. 1, DESCRIPTION OF PROPERTY: (Legal description of the property and street address if available) 2. GENERAL DESCRIPTION. OF IMPROVEMENT: installation of photovoltaie solar panels an rooftop. 3. OWNER INFORMATION OR LESSEE INFORMATION IF THE LESSEE CONTRACTED FOR THE IMPROVEMENT: Interest in property: owner Address: 4, CONTRACTOR: Name: Freedom Forever, LLC Phone Number: 727-294-7218 Address: 2010 51stAve E Ste ill Palmetto F1 34221 S. SURETY (if applicable, a copy of the payment bond is attached)* Name: Address:.— Amount of Bond:—___., 6o LENDER: Name: Phone Number: Address: 7. Persons within the State offlorida Designated by Owner upon whom notice or other documents maybe served as provided by Section 713,13(1)(a)7., Florida Statutes. Address: 8. In addition, Owner designates of to receive a copy of the Lienor's Notice as provided in Section 713. 13(l)(b), Florida Statutes, Phone number- 9. Expiration Date of Notice of Commencement (The expiration is 1 year from date of recording unless a different date is specified) WARNING TO OWkER.. ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT, "RF CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713,13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION, IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORV__Y BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. X VAO V� an -Li ct (Sid�tvry of , ort6h'M- �J— (Print Name and Provide Signatory a TitivOlffice) _Cmna, , or Owner's or LeNsee State 01 r5ofida County of Pasco The foregoing instrumen I twas acknowledged before me by means of [)a physical presence or C ] online notarization, this 12th day of May 20_4 , by (name of person acknowledging), who is personally known to me; or has produced as identification. 'kW C GRAY Notary Nblic - Stitt of Florida Signature of Notary iblic Cotnintislon # HH 114656 My Com. Expires Apr 6, 2025' Bonded through National Notary Assn, 13 State Of Florida, Count Of Pasco This is to certify that the foregoing Is a true and correct copy of the document • on file or of public record in this office, press my hands d official seal this .214 a^.,, day C�9!I b Nikki.7arez owlo w Clerk omptroller Pat5tdrlty,l� n �` y ,g putt' Clerk Current Renewables Engineering Attn: To Who It May Concern, Pr(�ject Name;JUAN MANAUTOU Project Address: STAMPED 06/h/tOA EXPZ28/2023 Per Florida Statute(F.S.) 377.705 (revised 7/1/2017), 1, Methode Maniraguha,PE (* 85003) an engineer licensed pursuant to Chapter 471, certify that the PV electrical system and electrical components are designed and approved using the code requirements and standards contained in the Florida Building Code. If you have questions regarding this matter, please do not hesitate to contact me directly. Prepared by: Current Renewables Engineering Inc. Riverside, CA Projec.ts@currentrenewableseng.com i 96o, Chicago Ave, Sitite 'Riverside, CA 92,507 ww%,v,,c,ti,i,rei,it:i-ei'tewableseiig.co,il'I ��%�L25 ,6!7 1N'1'E,GR1T'Y` PRO Fi�',SSTONAI,,IS'c%I"Ct"S'I'OMER'l-"�X,1"11�IgR,11,,All�"IN4'Cl',"I Current Renewables Engineering NOM Subject: Structural Certification for Installation of Residential Solar re job: JUAN MANAUTOU, 6214 SILVER OAKS DRIVE, ZEPHYRHILLS, FL, 33542 Attn,: To Whom It May Concern Afield observation was performed todocument the existing framing ufthe above mentioned address. From the field observation,theex|st|n'roofstructurewasmbsmrvedas: ROOF1: Shingle roofing supported by 2x4 Truss @ 24 in, OC spacing. The roof is sloped at approximately 22degrees and has amax beam span of6ftbetween supports. Code: 2OZ0F[Building Code s7thEdition (ASCE7-1G) U|tWind Speed: -145rnph Ground Snow: Opsf Exposure Cat: C Min Roof Snow: NA psf After review oYthe field observation and based onour structural capacity calculations inaccordance with applicable building codes, the existing roof framing supporting the proposed solar panel - layout has been determined tobe� � ' ROOF 1: adequate to support the imposed loads. Therefore, no structural upgrades are required, Current RenemeNesEngineering Inc. Professional Engineer pro]ects@cnan8.so|ar STAMPED06/W3/2022 EXP 2/28/2023 z��Avi,',SummD15,�dm,A�6� m�mA"wr"'n"'n 1 951,254�565,13 1NTE131 IN > PR(1'-,z,SSnONeU�A V cusT0xxsnsXwFm|FwCs urrent Renewables Engineering Freedom Forever LLC 43445 Business Park Dr Suite 110 Temecula, CA 92590 Attn,: To Whom It May Concern re job: JUAN MANAUTOU 6214 SILVER OAKS DRIVE, ZEPHYRHILLS, FL 33542 The following calculations are for the structural engineering design of the photovoltaic panels and are valid only for the structural info referenced in the stamped plan set. The verification of such info is the responsibility of others. After review, I certify that the roof structure has sufficient structural capacity for the applied PV loads. All mounting equipment shall be designed and installed per manufacturer's approved installation specifications. code Live Load: U It Wind Speed: Exposure Cat: Ground Snow: 2020 FL Building Code 7th Edition ASCE 7-16 20 psf 145 mph C 0 osf Min Roof Snow: NA Current Renewables Engineering Inc. Professional Engineer projects@ cren g.sola r I % k,,, a g c i d" 9 2 'S 0 7 960 C Ave, Suite D, \�` om 951,254,5655 IN 'T'i", G R H"Y PROFEWONAUSM C L IS TO Pvl [,, R ',-,X P E R I E N C L ^Current 'Engineering ` RoofType= RoofPkzh(deu)= Mean Roof —Height (fd= Attachment TribVVidth (t)= Attachment Spacing (ft)= Framing Type Framing Size " Framing OCSpacing (|nj- Section Thickness, h(in.)= SectionDepth, d (|n.) = Section Modulus, Sx(in .^3)= Moment ofInertia, |x(in .^4)= FraminA8pon(ft)= Defection UmitD+L (|n.) Deflection Limit So (in.) Framing Upgrade : Sister Size = Wood Species = Wood Fb(psi)= Wood Fv(pd)= Wood E(po|)= CD (Wind) ^ CD (Snow) [w=Ct=CL =Ci Cf" Cr F'b mdnd(ps|) F'b_snmvv(psi) Fnd(ps8 F'v_snow(psi) M_aUovvab\e_wind(|b4t M—allowable_snow(|b-ft) V_aUowable_wihd(|bd V_aUovvab|e_snow(|ba) E'(ps|) Load Calculation: l�Q0�h�a�mAve SumleD,11,,,��,,("A�2507 Job Code: ]UANMANAUTOU ,Current Dead Load Calculations: Job Code: JUANyWANAUTOU Panels Dead Load (psf)= 3.0 Roof I Roofing Weight (psD= 80 Decking Weight (psH= 2�0 Framing Weight (psH=. 06 Misc. Additional Weight (psf) = . 1.0 Existing Dead Load (pd)=' 6.6 Total Dead Load (psf)= 9,5 lWind Load Calculations: Ultimate Wind Speed (mph)= 145 Directionality Factor, kd= Q.85 Topographic Factor, kzt= 1.0 Roof 1 Velocity Press ExpFactor, kz =` 0.05 Ground Elevation Factur,ke= 1.00 Velocity Pressure, qz(psf)=' 30.8 Array Edge Factor, yE= 1,25 Solar Equalization Factor, ya= 038 External Pressure Up, GCp_1= -1.5 External Pressure Up, GCp_2 =' -2.2 External Pressure Up, BCp_3= -23 External Pressure Down, GCp= O�G ` Design Pressure Up, p_1(ps8= -51.0 Design Pressure Up, p_2 (psf)=` ~74.8 Design Pressure Up, p_3(psf)=' -78.2 Design Pressure Down, p (psf)=' 20.4 Ref VVidthravvo|Value, VV(|b/in)= 265 (Cm = C,= {'m= 1.0) C, = 1.6 Adjusted VVidthrama|Value, Ny(|bAn)=` 426 Lag Penetration, pOnj= 2.6 Allowable VVidt''� Force, VV'p(|bs)= 1064 Applied Uplift Fnrce(|bs) = -462 ' hc""I"'g,,n A ���,�hm������A 9,2,1,507 �M""KXwHNr�r�r�n�����me���o� current Renewables Engineering Ref. Lateral Value, Z (lbs) = 270 (CM = Ct = C6 = C'g = 1-0) CD = 0:9 Adjusted Lateral Value, Z' (lbs) = 243 Applied Laeral Force (lbs) = 15 Angle of Resultant Force, ex (deg) = 88 djusted Interaction Lateral Value, Z',. (lbs) = 1060 Lateral DCR = 0.01 Roof Framing rhprkqe Job Code: JUAN MANAUTOU 4 of 6 Force Checks: Roof I LC1: D+S Applied Moment (lb-ft) = 58 Applied Shear (lbs) = 58 Allowable Moment (lb-ft) = 524 Allowable Shear (Ibs) = 725 Moment DCR = 0.11 Shear DCR = 0.08 LC2: D+0.6W Applied Moment (lb-ft) = 131 Applied Shear (Ibs) = 131 Allowable Moment (lb-ft) = 729 Allowable Shear (Ibs) = 1008 Moment DCR = 0.18 Shear DCR = 0.13 LC3: D+0.75(S+0,6W) Applied Moment (lb-ft) = 113 Applied Shear (lbs) = 113 Allowable Moment (lb-ft) = 729 Allowable Shear (Ibs) = 1008 Moment DCR = 0.15 Shear DCR = 0.11 LC4: 0.6D+0.6W Applied Moment (lb-ft) = 149 Applied Shear (lbs) = 149 Allowable Moment (lb-ft) = 729 Allowable Shear (lbs) = 1008 Moment DCR = 0.20 Shear DCR = 0.15 I 'K 1960 "m"te, Rivt,,�skle, CA 9,2,,5("),7 `5 i"i 5 Job Code: JUAN MANAUTOU Current 5of6 }�� i\:��Y1 ihw \nib'' x'l`'z �`��2��� �,�. U� � e `pggp�lrn �k� "`.\� ��*M12 i ��v. `�eN Engneering Deflection Checks Service Level ; Roof 1 LCl: D+L Deflection (in.) = 0.02 Deflection Limit (in.) = 1.38 Deflection DCR = 0.01 LC2: S Reflection (in.) = 0.00 Deflection Limit (in.) = 0.92 Deflection DCR = 0.00 LC3: W (Down) Deflection (in.) = 0.01 Deflection Limit (in.) = 0.92 Deflection OCR = 0.01 LC4: W (Up) Deflection (in.) = -0.03 Deflection Limit (in.) = 0.92 Deflection DCR = 0.03 Seismic Check: Existin Wei" ht: Wall Weight (psf) = " 17 Tributary Wall Area (ft) = 1000 Total Wall Weight (lbs) = 17000 Roof Weight (psf) = 7 Roof Area (ft) = 2400 Total Roof Weight (lbs) = 15844 Total Existing Weight (lbs) = 32844 Additional PV Weight: Total Additional PV Weight (lbs) = 926 Weight lncrease: (Existing W + Additional W)/(Existing W) = 103% The increase in weight as a result of the solar system is less than 10% of the existing structure and therefore no further seismic analysis is required. Limits e�f 5co�a of Work ertd Liabilii�� Existing structure is assumed to have been designed and constructed following appropriate codes at M, ?.)a., ek °"i�,.4. Avi,% St. xk`C CA u .5{.e„7 .',., 951 P.; u iN T k.("'R'ITY P P, 0 ltl5,{'., N A L ,:fir'} t.U; S i',, N"If,lt CAN,,iRIE vt,.k<:. Job Code: JUAN MANAUTOU Current 6 of 6 Renewables Engineering time of erection, and assumed to have appropriate permits. The calculations produced are only for the roof framing supporting the proposed PV installation referenced in the stamped planset and were completed according to generally recognized structural analysis standards and procedures, professional were not observable during time of inspection are not included in this scope of work, All PV modules, racking, and mounting equipment shall be designed and installed per manufacturer's approved installation specifications, The Engineer of Record and the engineering consulting firm assume no responsibility for misuse or improper installation. This analysis is not stamped for water leakage. Framing was determined based on information in provided plans and/or photos, along with engineering judgement. Prior to commencement of work, the contractor s all veri t e raming sizes, spacings, an spans noted in the stamped plans, calculations, and cert letter (where applicable) and notify the Engineer of Record of any discrepancies prior to starting construction, Contractor shall also verify that there 'is no damaged framing that was not addressed in stamped plans, calculations, and cert letter (where applicable) and notify the Engineer of Record of any concerns prior to starting construction. 19f,5 i VV 'IN" ,J� 11,11nteb1c, sw iq,,,, oo flN,-I,'E,,'S'IIP'YfY P,R (,) f E S S � -0 N A iJ S KII CUSTONI�',',R i,-,XPEI'-RiEN0,,, SYSTEM CODES:PHOTOVOLTAIC CONSTRUCTION NO THIS PROJECT COMPLIES WITH THE FOLLOWING: 2020 7TH EDITION FLORIDA BUILDING CODE: BUILDING CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND a.. 2020 7TH EDITION FLORIDA BUILDING CODE: RESIDENTIAL ARE NOT MEANT TO LIMIT UP -SIZING AS REQUIRED BY FIELD CONDITIONS. 2020 7TH EDITION FLORIDA BUILDING CODE: MECHANICAL ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE MAXIMUM EXTENT 2020 7TH EDITION FLORIDA BUILDING CODE: PLUMBING POSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR TO THE SURFACE UPON WHICH THEY ARE 2020 7TH EDITION FLORIDA BUILDING CODE: FUEL GAS MOUNTED. 2020 7TH EDITION FLORIDA BUILDING CODE: ENERGY CONSERVATION MODULES SHALL BE TESTED AND 1NDENTiF1ED WITH FIRE CLASSIFICATION 1N 2020 7TH EDITION FLORIDA BUILDING CODE: EXISTING BUILDING ,LISTED ACCORDANCE WITH UL 2703. SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PER 2020 7TH EDITION FLORIDA BUILDING CODE; ACCESSIBILITY SECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD. 2020 7TH EDITION FLORIDA FIRE PREVENTION CODE (NFPA) 2017 NATIONAL ELECTRIC CODE (NEC) DIG ALERT (811) TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY PRIOR TO ANY AS ADOPTED BY CITY OF ZEPHYRHILLS EXCAVATION TAKING PLACE - PHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT MAIN SERVICE FROM DC DISCONNECT/INVERTER AS PER 2017 NEC SEC 250.166(A). TAMPE ib fti3/2022 EX 2/28/2023 SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF ART. 690 OF THE 2017 NEC ICI THE MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROD OR LIFER UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEM SOLAREDGE OPTIMIZERS ARE LISTED TO IEC 62109-1 (CLASS 11 SAFETY) AND UL 1741 STANDARDS CLIENT: JUAN MANAUTOU INSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUIT 6214 SILVER OAKS DRIVE, zEPHYRHILLS, FL ATTACHED TO THE ROOF USING CONDUIT MOUNT. 33542 AHJ: CITY OF ZEPLiYRHiLLS 4s UTILITY: DUKE ENERGY (FL) fr' 1. Prig to commencement of error:, the contractor shalt verify the framing sizes, PHONE: $13469$556 spacings, and spans noted in the stamped plans and accompanying calculations = and notify the Engineer of Record of any discrepanr ses prior to starting construction. 2, These plans are stamped for structural code compliance of the mof framing supporting the proposed PV installation referenced only. These plans are not stamped for water leakage. PV modules, racking, and attachment components SYSTEM: must foi3o3nrrrranu#acturetguideliaaesand requ,eerlenis- :17 X 415 DC = 7,055 kto SYSTEM SIZE (DC): S, Please see accompanying Structural Calculations report for details regarding SYSTEM SIZE (AC): 5.000 kW @ 240V calculations as well as limits of scope of work and iiauility. MODULES: 17 X CANADIA# SOLAR: CS3N-415MS OPTIMIZERS: 17 X SOLAREDGE S440 '.. THIS SYSTEM IS DESIGNED FOR INVERTER: SOLAREDGE SE500OH-US [SI1] WIND SPEED: 145 MPH CATEGORY C EXPOSURE --- --- — ----- ---------------- ---------------------------------- DOTE TO INSTALLERS: VERIFY THE ROOF FRAMING INFO BEFORE INSTALLATION AND NOTIFY SITE LOCATION THE FOR AT IF THERE IS ANY INCONSISTENCY BETWEEN SITE VERIFICATION AND FOLLOWING: WITH MAXUNSUPPORTED I�AP� T F CONTENTS: EQUAL OR LESS THAN 6 FT,CI PV-1 SITE LOCATION REVISIONS PV-2 SITE PLAN NO. REVISED BY {SATE PV-2A ROOF PLAN WITH MODULES LAYOUT PV-2B STRUCTURAL CALCULATIONS - - - PV-3 MOUNTING DETAILS freedom PV-4 THREE LINE DIAGRAM F 0 R, v r .. PV-5 CONDUCTOR CALCULATIONS FREEDOM FOREVER 0 LC 2619 CONSULATE DR SUITE $Ofl, ORLAND6, PV-6 EQUIPMENT & SERVICE LIST Tel: FL3z$1s ($00) 3$5-5075 PV-7 LABELS GREG ALBRIGHT F PV-7A SITE PLACARD , Iz PV-8 OPTIMIZER CHART :. PV_9 SAFETY PLAN CONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR PV-10 SAFETY PLAN EC13008056 APPENDIX MANUFACTURER SPECIFICATION SHEETS SITE LOCATION JOB NO: DATE: DESIGNED BY: [SHEET: 230674 5130/2022 A.MS- PV_q I LEGEND: BOB WILL BE AS CLOSE AS POSSIBLE TO MSP WITHIN 10' THIS SYSTEM DESIGNED WITH: L,__111 OBSTRUCTION WIND SPEED: 145 0 PIPE VENT MODULES CONDUIT SETBACK AC] F AC C-1 DISCONNECT 1; Fspl MSP 0 JUNCTION BOX FINV] INVERTER P—M] [ PRODUCTION METER PV-SYSTEM 7.055 kW -DC 5.000 kW -AC (E) MAIN SERVICE PANEL (IN GARAGE) (E) UTILITY METER (N)AC DISCONNECT EATON DG221URB (OR EQUIVALENT) (N) SOLAREDGE SE500OH-US [Sji] INVERTER WITH RAPID SHUTDOWN (N) JUNCTION BOX (N) 17 CANADIAN SOLAR: CS3N-415MS (415W) 4 PROPERTY LINE I ROOF AREA: 3089 SO FT i CLIENT, JUAN MANAUTOU 6214 SILVER OAKS DRIVE. ZEPHYRHiLLS, F 33542 AHJ: CITY OF ZEPHYRHILLS UTILITY: DUKE ENERGY (FL) PHONE: 8134698556 SYSTEM SIZE (DC): 17 X 415 = 7.055 kW SYSTEM SIZE (AC): 5.000 kW @ 240V MODULES: 17 X CANADIAN SOLAR: CS3N-415MS OPTIMIZERS: 17 X SOLAREDGE S440 INVERTER: SOLAREDGE SE500OH-US [S11 REVISIONS I I NO. REVISED BY I DATE I freedom C, I v I R FREEDOM FOREVER LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 GREG ALBRIGHT CONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 SITE PLAN JOB NO: I DATE:DESIGNEDBY. SHEET: 230674 5/30/2022 A.M, PV-2 LEGEND: MODIFIED SETBACKS PROPOSED AT RIDGE: TOTAL ARRAY AREA = 372.13 SF TOTAL ROOF AREA = 3089 SF OBSTRUCTION TOTAL ARRAY AREA AS A % TO ROOF AREA = 12.05% 12.05% < 33% 0 PIPE VENT 11 MODULES BOS WILL BE AS CLOSE AS POSSIBLE TO MSP WITHIN 10' CONDUIT r/2 SETBACK F- AC] AC DISCONNECT Fm -sp] MSP JUNCTION BOX I 7NV INVERTER Fp-ml PRODUCTION METER PV SYSTEM 7.055 kW -DC 5.000 kW -AC THIS SYSTEM DESIGNED WITH: WIND SPEED: 145 m ROOF PLAN ' SCALE: 3/321f 1r-o-0- 11 ROOF AREA: 3089 SO FT CLIENT: JUAN MANAUTOU 6214 SILVER OAKS DRIVE, ZEPHYRHILLS, FL ESS 33542 Ifs AHJ: CITY OF ZEPHYRHILLS UTILITY: DUKE ENERGY (FL) PHONE: 8134698556 NOTES: 1, EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNTS 2. ATTACHED CLAMPS AT 25% FROM THE EDGE AND 50% FROM THE CENTER OF THE MODULES 3. JUNCTION BOX IS MOUNTED TO THE RAIL. SYSTEM SIZE (DC): 17 X 415 = TOSS kW SYSTEM SIZE (AC): 5.000 kW @ 240V MODULES: 17 X CANADIAN SOLAR: CS3N-415MS OPTIMIZERS: 17 X SOLAREDGE S440 INVERTER: SOLAREDGE SE500OH-US [Sill REVISIONS '10- REVISED BY DATE freedom FREEDOM FOREVER LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 GREG ALBRIGHT CONTRACTOR K E- CERTIFIED ELECTRICAL CONTRACTOR EC13008056 ROOF PLAN WITH MODULES LAYOUT JOB NO: DATE: DESIGNED BY: SHEET: 230674 5/30/2022 A.M.PV-2A -ffEi!!m ARRAY FLOOR PLAN WITH MODULES LAYOUT Scale- NTS ii6CT OR STRUCTURAL SCREW WITH 2-1/2" MIN. EMBEDMENT AND FLAT WASHER PV ARMY SECTION VIEW So JMle- NTS MAX ATTACHMENT SPAN - TA GEED NOTE TO INSTALLERS: VERIFY THE ROOF FRAMING IN BEFORE INSTALLATION AND NOTIFY THE ECIR AT IF THERE IS ANY INCONSISTENCY BETWEEN SITE VERIFICATION AND FOLLOWING: 2x4 TRUSSES @ 24" SIC SPACING WITH MAX UNSUPPORTED SPAN 0), ull S�V_` TRIMRAIL CANADIAN SOLAR: CS3N-415MS SLIDER AND TRIMRAIL ROOF ATTACHMENT ROOF DECK MEMBRANE !ING STAINLESS STEEL LAG OR STRUCTURAL SCREV 12-112" MIN. EMBEDMEN FLAT WASHER BUILDING STRUCTURE ATTACHMENT DETAIL Scale: NTS ffiffiffm tt ed S_ _4 ICRORAIL :ANADIAN SOLAR: :S3N-415MS ROOF / DECK MEMBRANE ;LIDERS 9FOAMIRM /16" STAINLESS STEEL AG BOLT OR ;TRUCTURAL SCREW VITH 2-1/2" MIN. ,MBEDMENT AND FLAT VASHER CLIENT: JUAN MANAUTOU 6214 SILVER OAKS DRIVE, ZEPHYRHILLS, 33542 AHJ: CITY OF ZEPHYRHILLS UTILITY: DUKE ENERGY (FL) PHONE: 8134698556 SYSTEM: SYSTEM SIZE (DC): 17 X 415 = 7.055 kW SYSTEM SIZE {AC}: 5.000 kW @ 240V MODULES: 17 X CANADIAN SOLAR: CS3N-415MS OPTIMIZERS: 17 X SOLAREDGE S440 INVERTER: SOLAREDGE SE500OH-US [SI11 I I REGIONS I NO, I REVISED IY 1 DATE freedom FREEDOM FOREVER LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385- 1075 GREG ALBRIGHT CONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 G DETAILS MOUNThIN,.d JOB NO: I DATE: I DESIGNED BY. SHEET: 230674 5/3012022 1 AM, PV-3 BACKFEED BREAKER SIZING MAX. CONTINUOUS OUTPUT 21.00A @ 240V 21.00 X 1,25 = 26.25AMPS 30A BREAKER - OK SEE 705.12 OF 2017 NEC 150 X 1.20 = 180 180 - 150 = 30A ALLOWABLE BACKFEED PVSYSTEM T055 kW -DC 5.000 kW -AC STRING-1 ^S3 415MS(4151,'V) SOLAREDGE S440 POWER OPTIMIZERS 2 - #10 AWG, _ PV WIRE 1 STRING-2 I 9 CANADIAN SOLAR: CS3N-415MS(4151P1) ] I JUNCTION BOX I (�1 ---------------- SOLAREDGE S440 POWER OPTIMIZERS 2 - #10 AWG, PV WIRE 1 - #6 AWG IN FREE AIR OR #8 AWG MUST BE IN EMT CONDUIT (N)SOLAREDGE SE500OH-US [SI1] \INVERTER F \A7C _ RAPID SHUTDOWN 4 #10 AWG, THWN-2 SWITCH 1 - #8 EGG THWN-2 IN 3/4" OR LARGER EMT CONDUIT (N)30A RATED AC DISCONNECT EATON DG221URB (OR EQUIVALENT) KNIFEBLADE, LOCKABLE, NEMA 3R, UL LISTED a 3 - #10 AWG. THWN-2 1 - #8 EGO, THWN-2 IN 314" OR LARGER EMT CONDUIT 3 - #10 AWG, THWN-2 1 -#6 EGG, THWN-2 IN 3!4" OR LARGER EMT CONDUIT IN) 30A! 2P PV BREAKER STAMP 06/0 3t202 EXP 2/2812 2 (E) UTILITY METER (E) 150A RATED MAIN SERVICE PANEL 1PH, 120/240V 60HZ (E) 150A ! 2P MAIN BREAKER (BOTTOM FED) ICONNECT TO EXISTING UFER NOTE: CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP -SIZING AS REQUIRED BY FIELD CONDITIONS JUAN MANAUTOU 6214 SILVER OAKS DRIVE, ZEPHYRHILLS, 33542 AHJ: CITY OF ZEPHYRHILLS UTILITY: DUKE ENERGY (FL) PHONE: 8134698556 SYSTEM: SYSTEM SIZE (DC): 17 X 415 = 7.055 kW SYSTEM SIZE (AC): 5,000 kW @ 240V MODULES: 17 X CANADIAN SOLAR: CS3N-415M S OPTIMIZERS: 17 X SOLAREDGE S440 INVERTER: SOLAREDGE SE500OH-US [SI1j REVISIONS UO. REVISED BY DATE freedom FREEDOM FOREVER LLC 2619 CONSULATE DR SUITE 800, ORLANDO. FL 32819 Tel: (800) 385-1075 GREG ALBRIGHT fi 1 ' n. f CONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 THREE LINE DIAGRAM JOB NO: I DATE: I DESIGNED BY: SHEET: 230674 5!30!2022 A.M. PV-4 MODULE INFO MAKE/MODEL: CANADIAN SOLAR: CS3N-415MS Voc: 45A V Vmp: 37.8 V ISO: 11,68 A Imp: 10.98 A STC RATING: 415 W RTC RATING: 415 W MAX DC CURRENT: Imax = 1.25 X (OPTIMIZER OUTPUT CURRENT) = 1.25 X 15 = 18.75A MAX AC CURRENT: Imax = 1.25 X (SUM OF MAX CONTINUOUS OUTPUT CURRENT FROM INVERTERS) = 1.25 X (21,00) = 25.25A AMPED 0603/2 2 EX 2/28/2023 WIRE SCHEDULE CLIENT: JUAN MANAUTOU RACEWAY # EQUIPMENT WIRE LOCATION CONDUCTOR QTY. AWG WIRE SIZE STARTING ALLOWABLE AMPACITY @ 90°C 310.15(B)(16) STARTING CURRENT APPLIED TO CONDUCTORS IN RACEWAY TEMPERATURE CORRECTION FACTOR FACTOR 310,15(B)(2)(a) ADJUSTMENT FACTOR FOR MORE THAN 3 310.15(B)(3)(a) ADJUSTED CONDUCTOR AMPACITY @ 90°C MAXIMUM CURRENT APPLIED TO CONDUCTORS IN RACEWAY 6214 SILVER OAKS DRIVE, ZEPHYRHILLS, FL 33542 AHJ: CITY OF ZEPHYRHILLS UTILITY: DUKE ENERGY (FL) PHONE:8134698556 1 2 DC DC MODULE OPTIMIZER TO TO OPTIMIZER JUNCTION BOX ROOF / FREE -AIR ROOF I FREE -AIR 2 2 10 10 40 40 14.60 15,00 1 1 1 1 40.00 40.00 18.25 18.75 3 DC JUNCTION BOX TO INVERTER EXTERIOR WALL 4 10 40 15.00 1 0.8 32:00 18,75 SYSTEM; SYSTEM SIZE (DC): 17 X 415 = 7.055 kW 4 AC INVERTER TO AC DISCONNECT EXTERIOR WALL 3 10 40 21.00 1 1 40.00 26.25 zOLARR: MODULES: 17 X SYSTEM SIZE CA 5.000NADIAN SOLAR: 5 AC AC DISCONNECT TO POI EXTERIOR WALL 3 10 40 21.00 1 1 40.00 26,25 Cs3N-415Ms OPTIMIZERS: 17 X SOLAREDGE 5440 INVERTER: SOLAREDGE SE500OH-US [SH REVISIONS NO. REVISED BY DATE freedom FREEDOM FOREVER LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 GREG ALBRIGHT r CONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 CONDUCTOR AMPACITY CALCULATIONS IN ACCORDANCE WITH NEC 690.8. CONDUCTOR CALCULATIONS JOB NO: I DATE; I DESIGNED BY: I SHEET: 230674 5130/2022 AM- PV5 BREAKER SIZES: SERVICE LIST: 30A PV BREAKER MATERIAL LIST: QTY.jPART PART # 17 MODULES 116-415 17 OPTIMIZERS S440 I JUNCTION BOX 480-276 2 CONNECTORS 240-300 2 CONNECTORS 240-301 I INVERTER 120-501 1 AC DISCONNECT 321-030 67 ROOF ATTACHMENT 1 261-602 13 SFM TRIM 1 241-253 33 SFM SLIDER 1 261-603 10 BONDING CLAMP 1 221-100 4 BONDING CLAMP 1 241-404 18 MOUNT ASSEMBLY 1 241-405 11 SFM SPLICE 1 261-604 3 SFM ATTACHED SPLICE 1 211-101 14_ TRIMRAIL 1 261-606 5 TRIM SPLICE 1 261-605 8 TRIMRAIL 1 211-115 17 GROUND LUG I 260-585 17 F --TRIM END CAPS I 221-200 DESCRIPTION CANADIAN SOLAR: CS3N-415MS SOLAREDGE S440 POWER OPTIMIZER - FRAME MOUNTED MODULE ADD -ON 600VDC NEMA 3R UL LISTED JUNCTION BOX STAUBLI I MULTI -CONTACT MC4 CONNECTORS (FEMALE) STAUBLI / MULTI -CONTACT MC4 CONNECTORS (MALE) SOLAREDGE SE500OH-US [S11] 240V INVERTER UL1741 SA CERTIFIED INTEGRATED ARC FAULT PROTECTION AND RAPID SH '30A RATED 240VAC NEMA 3R UL LISTED SFM INFINITY \ ROCKIT MICRORAIL FLASHKIT SFM I ROCK -IT TRIM COMP DARK PA*T FLASHKIT SFM / ROCK -IT SLIDER COMP DARK NUMBER PART TYPE N/S BONDING CLAMP TRIM BONDING CLAMP MLPE MOUNT ABBY SFM / ROCK -IT SPLICE ATTACHED SPLICE 8 INCH TRIMRAIL UNIV CLIP W/ HOW TRIM SPLICE DRK TRIMRAIL UNIV DRK ILSCO GROUND LUG UNIRAC SFM / ROCK -IT TRIM END CAPS DESCPIPTION SUGMTED QUANTITY QUANINTY STAMPM) 06/0312022 EXP 2/28/2023 JUAN MANAUTOU 6214 SILVER OAKS DRIVE, ZEPHYRHILLS, FL 33542 AHJ: CITY OF ZEPHYRHILLS UTILITY: DUKE ENERGY (FL) PHONE: 8134698556 SYSTEM: SYSTEM SIZE (DC): 17 X 415 = 7.055 kW SYSTEM SIZE (AC): 5.000 kW @ 240V MODULES: 17 X CANADIAN SOLAR: CS3N-415MS OPTIMIZERS: 17 X SOLAREDGE S440 INVERTER SOLAREDGE SE500OH-US [Sill REVISIONS ASED BY freedom FREEDOM FOREVER LLC 2619 CONSULATE DR SUITE 800, 5RLANDO, FL 32819 Tel: (800) 385-1075 GREG ALBRIGHT CONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 EQUIPMENT & SERVICE LIST JOB NO: DATE: DESIGNED BY: I SHEET: 230674 15/30/2022 �PV-6 ------- --- 705,12(B)(2)(3)(b) mmmz�� TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN ENTIRE PSI SYSTEM N I INVERTER H you have any questions about your rilasm, please call our Custome r Support Teafn at 1388.557-6431 or vlaft This War FV SYMM r Inemli" by fmtedom- 690.53 ARRAY CLIENT: JUAN MANAUTOU 6214 SILVER OAKS DRIVE, ZEPHYRHILLS, 33542 AHJ: CITY OF ZEPHYRHILLS UTILITY: DUKE ENERGY (FL) PHONE: 8134698556 SYSTEM SIZE (DC): 17 X 415 = 7,055 kW SYSTEM SIZE (AC): 5,000 kW @ 240V MODULES: 17 X CANADIAN SOLAR: CS3N-415MS OPTIMIZERS: 17 X SOLAREDGE S440 INVERTER: SOLAREDGE SE500OH-US fS111 REVISIONS N0. �--REVISED BY DATE freedo"', FREEDOM FOREVER LLCM 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 GREG ALBRIGHT J CONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 LABELS NFPA 11,12.2.1,111 JOB NO: DATE: I DESIGNED BY: SHEET! E 230674 5/30/2022 A.M.V, PV-7T 1. NEC ARTICLES 690 AND 705 AND FBC SECTION R324 MARKINGS SHOWN HEREON, 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING, B. RED BACKGROUND COLOR WHITE TEXT AND LINE WORK. C. AERIAL FONT, 3, ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE HAND-WRITTEN, 4, SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP -RIVETS OR SCREWS, STAMPED 0610,3/2 2 EXP 2/28/2023 CLIENT: JUAN MANAUTOU 6214 SILVER OAKS DRIVE, ZEPHYRHILLS. 33542 AHJ: CITY OF ZEPHYRHILLS UTILITY: DUKE ENERGY (FL) PHONE: 8134698556 SYSTEM: SYSTEM SIZE (DC): 17 X 415 = 7.055 kW SYSTEM SIZE (AC): 5.000 kW @ 240V MODULES: 17 X CANADIAN SOLAR: CS3N-415MS OPTIMIZERS: 17 X SOLAREDGE S440 INVERTER: SOLAREDGE SE500OH-US (Sill I I REVISIONS 1 I NO.. REVISED BY I DATE freedom FREEDOM FOREVER LLC 2619 CONSULATE DR SUITE 800, ORLANDO. FL 32819 Tel: (800) 385-1075 GREG ALBRIGHT f 3 CONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 SITE PLACARD JOB NO: 1 DATE: DESIGNED BY: SHEET: 230674 5/30/2022 A.M, I PV-7A SAFETY PLAN MARK UP KEY INSTRUCTIONS-- 1 . USE SYMBOLS IN KEY TO MARK UP THIS SHEET. � PER ANENT A CHOR 2. SAFETY PLAN MUST BE MARKED BEFORE JOB STARTS AS PART OF THE PRE -PLAN 1 DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE TEMPORARYANCHOR & MAKE NOTES ON THE JHA SHEET IN CASE OF IL EMERGENCY INSTALLER LADDER NEAREST HOSPITAL OR OCCUPATIONAL/INDUSTRIAL CLINIC FI3 1 JUNCTION / COMBINER BOX Co NAME: 0 STUB -OUT ADDRESS: SKYLIGHT SAFETY COACH CONTACT INFORMATION LADDER ACCESS (STEEP CLIENT: .IUAN MANAUTOu NAME: , <' GRADE OR GROUNDLEVEL 36214 35421LVEROAKSDRIVE,ZEPFYRHILLS FL I l AHJi CITY OF ZEPHYRHILLS PHONE NUMBER, \ OBSTRUCTIONS) UTILITY: DUKE ENERGY (FL) PHONE:8134698555 ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THE SAFETY PLAN AND SIGN INDICATING THAT THEY ARE RESTRICTED ACCESS AWARE OF THE HAZARDS ON -SITE AND THE PLAN FOR \ WORKING SAFELY. `� � ' � � �� CONDUIT °*�q#�gD � `1. 1a�.J["dt,.Jl..9T SYSTEM: "+..0 SYSTEM SIZE (DC): 17 X 435 = 7.055 kW SYSTEM SIZE (AC): 5,000 kW @ 240V NAME SIGNATURE MODULES: 17 X CANADIAN SOLAR: GAS SHUT OFF CS3N-415MS , OPTIMIZERS 17 X SOLAREDGE 5440 INVERTER: SOLAREDGE SE5000H-US [Sill H2OrvATER SIT OFF g 171 SERVICE DROP POWER LINES REVISIONS NO. REVISED BY DATE freedom FREEDOM FOREVER LLC 2619 CONSULATE DR SUITE 800. ORLANDO, FL 32819 Tel: (800) 385-1075 DATE: TIME; GREG ALBRIGHT re CONTRACTOR L#CENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 SAFETY PLAN .JOB NO: DATE: I DESIGNED BY: SHEET: 230674 5130/2022 A, , PV-9 JOB HAZARD ANALYSIS Crew leader to fill out all sections below, hold a pre -job safety meeting with all personnel, and upload this completed document and the Safety Plan to Site Capture Ladder Access ® Ladders must be inspected before each use. • Extension ladders must be set up on a firm and level surface at a 4-to-1 rise to run angle (or 75 degrees) and the top must be secured to the structure. Extension style ladders placed on uneven, loose or slippery surfaces must additionally have the base firmly anchored or lashed so the base will not slip out. ® Extension ladders must be used with walk-through devices or the ladder must extend 36" above the stepping off point. • A -frame ladders must only be climbed with the ladder spreader bars locked in the open position-, A -frame ladders shall not be climbed while in the closed position (ex, closed and used while leaned against a structure). 0 Additional notes: Mobile Equipment ® Only Qualified operators will operate equipment; operators must maintain a certification on their person for the equipment being operated. • Type(s) of mobile equipment (Type/Make/Model): Crew leader responsible for communication with the client: 1 Heat Related Illness Prevention NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE 0 Employees shall have access to potable drinking water that is (add as many as necessary by using additional sheets) Client and public is excluded from work area by barricades (N/A, fresh, pure, and suitably cool. The water shall be located as Define the Hazard: Method/steps to prevent incident: Yes, No): close as practicable to the areas where employees are working. Water shall be supplied in sufficient quantity at the beginning of Traininq and Pre -Job Safety Briefing the work shift to provide at least one quart per employee per • All employees onsite shall be made aware of the specific hazards hour for drinking for the entire shift. Employees may begin the of this project and review this HJA during a pre -job briefing, and shift with smaller quantities of water if they identify the location Define the Hazard: Method/steps to prevent incident: their signature indicates awareness of site conditions and the and have effective means for replenishment during the shift to plan to eliminate any hazards identified prior to and during the allow employees to drink on quart or more per hour. The project. frequent drinking of water shall be encouraged. 0 Shade shall be present when temperature exceeds 80 degrees • Crew leader (nameftitle): Fahrenheit. When the outdoor temperature in the work exceeds Define the Hazard: Method/steps to prevent incident: 80 degrees Fahrenheit, employees shall have and maintain one Crew member (narneftitle): or more areas with shade at all times. New employees must be acclimatized. New employees will be ® Crew member (name/title): monitored by their Crew Leader (site supervisor) for the first two (2) weeks of employment or longer when necessary, Define the Hazard: Method/steps to prevent incident:I I a Crew member (name/title): Employees will be allowed and encouraged to implement scheduled breaks during each shift. Employees must take Crew member (name/title): cool -down breaks in the shade any time they feel the need to do Qualified operator(s): I I so to protect them from overheating. Supervisors are Crew member (na ffitla): REQUIRED to allow employees any break period they need LLIENT Material Handlingand,�a a during high heat conditions. JUAN MANAUTOU Materials will be staged/stored in a way that does not present a Airborne Contaminants: a Cool Vests are encouraged for all employees at all times during 6214 SILVER OAKS DRIVE, ZEPHYRHILL hazard to client, personnel or public. Materials stored on the 0 Asbestos -containing (Transite) piping (ACP) - Do not disturb periods of high heat, 33542 AHJ: CITY OF ZEPHYRHILLS roof will be physically protect from failing or sliding off. (move, drill, cut fracture, etc.) 0 Identify the location of the closet Occupational/Industrial Clinic LITILITY� DUKE ENERGY (FL) ® Asbestos -containing thermal insulation (ACI) and or Hospital in case a crew member becomes ill. PHONE: 8134698556 Fall Protection • A site -specific plan for fall prevention and protection is required prior to starting work and must remain onsite at all times until work is complete; a fall rescue plan must be outlined and discussed among the crew prior to work start. • First -person -Up (FPU) must install their anchor and connect before any other task, including installing other anchors. The Last -Person -Down (LPD) must be the only person on a roof uninstalling fall protection. FPCP (name and title): FPU and LPD (name and title): Electrical §afety * The Electrical Qualified Person (EQP) is required onsite to perform electrical work, * All electrical work will be performed with equipment in an electrically safe condition (de -energized) unless approval has been granted prior to work. * Service drops and overhead electrical hazards will be indentified and protacted from contact, as neccessary. 0 EQP (name and tile): Public Protection • The safety of the Client and Public must be maintained at all times. • The Client and the Public shall be prevented from entering the work zone through the use of barriers and/or signage, as required. • Company, Client and Public property shall be protected from failing objects. • Pets (including dogs) shall be secured by their owners prior to work start. • The Client should not leave pets, family members, or others in charge or care of Employees, Contractors, or Temporary Workers. Asbestos -containing duct wrapping (ACW) - do not disturb, no attic or crawlspace access is allowed if work to be performed could cause exposure to personnel, client or public. 9 If yes, list specific tasks and protection in place: Weather and Environment * The site supervisor shall forecast the weather conditions at the job site, prior to crew arrival, in order to mitigate any hazards associated with inclement weather (heat, cold, wind, rain, etc.) * The site supervisor will utilized a portable wind meter (anemometer) to verify actual onsite wind conditions, by checking at the ground and on any elevated work surface (ex, rooftop) prior to work start, at midday and prior to solar panel staging on a roof. ® Elevated work involving the moving or maneuvering of solar panels shall cease at 25mph (sustained wind) until wind subsides, * Forecasted weather maximum temp (degrees f): What is the specific plan to provide and replenish sufficient water for all employees on site? If offsite replenish is necessary, where will you go to replenish water (location/address), " Who will replenish the drinking water (name): Restroom facilities a Employees shall have access to restroom facilities with hand -washing stations. Use of onsite restroom is at the client's discretion (location is annotated below). If client does not give permission, location of suitable restroom facilities with hand -washing stations offsite will be provided. The onsite supervisor will identify location and make arrangements to ensure all employees have access at any point, 9 Restroorn facilities will be (circle one): Onsite - Offsite If Offsite, add location name and address: Incident Reporting Procedure Contact your Site Su ervisor Name: EPhone: Contact your Manager Name: Contact your Site Supervisor Name: Phone: With: Your full name, phone number, office location, brief description of what happen and when, F Current o Y' ,S Y�ts l�� l� \ 4 Y 1 Ys� s * `5 q R 18 5 ^ f` y 4 S.ak Engineering w t n Junl,2022 a t k Attn: To It May Concern, Project A re z6 14 SILVER OAKS DRIVE, ZED HILLS FL 33542 Per Florida Statute(PeS®) 377.705 (revised 7/1/01), I Methode Maniraguha,PE (# 85003) an engineer licensed pursuant to Chapter 471, certify at the PV electrical system and electrical components are designed and approved using the wide requirements and standards contained in the Florida Building Loden If you have questions regarding this matter, please do not hesitate to contact me directly; Sincerely, Prepared by: Current Renew tiles Engineering Inc. Riverside, CA Projects@currentrenewableseng.com ,i.96 (,"hic g e pit 1)15 Ri'%;,"er side, CA 92507 Current Renewabi Engineeringes 6/1/2022 Freedom Forever LLC, 43445 Business Park Or Suite 110, Temecula, CA 92590 Subject: Structural Certification for Installation of Residential Solar re job: JUAN MANAUTOU, 6214 SILVER (OAKS DRIVE, 2EPHYRHILLS, FL, 33542 Attn.: To Whom It May Concern A field observation was performed to document the existing framing of the above mentioned address. From the field observation, the existing roof structure was observed as: ROOF 1: Shingle roofing supported by 2x4 Truss @ 24 in. OC spacing. The roof is sloped at approximately 22 degrees and has a max beam span of 6 ft between supports. 2esin Criteria: Code: 2020 FL Building Code 7th Edition (ASCE 7-16) Ult Wind Speed. 145 mph Ground Snow: 0 psf Exposure Cat: C Min Roof Snow: NA psf After review of the field observation report and based on our structural capacity calculations in accordance with applicable building codes, the existing roof framing supporting the proposed solar panel layout has been determined to be: ROOF 1: adequate to support the imposed loads; Therefore, no structural upgrades are required. Current Renewables Engineering Inc. Professional Engineer projects @creng.solar 9 53,. t 53. .5 )N i E. toRI Y kR0 $' t.,u, t NA1,t`tIV; urrent Renewables Engineering Freedom Forever LLC 43445 Business Park Dr Suite 110 Temecula, CA 92590 Attn.: To Whom It May Concern re job: JUAN MANAUTOU 6214 SILVER OAKS DRIVE, ZEPHYRHILLS, FL 33542 The following calculations are for the structural engineering design of the photovoltaic panels and are valid only for the structural info referenced in the stamped plan set. The verification of such info is the responsibility of others. After review, I certify that the roof structure has sufficient structural capacity for the applied Pit loads. All mounting equipment shall be designed and installed per manufacturer's approved installation specifications, Code: 2020 FL Building Code 7th Edition ASCE 7-16 Live Load: 20 psf Ult Wind Speed: 145 mph Exposure Cat: CitoW I �N` V N1 A X6 Ground Snow: 0 psf Min Roof Snow: NA tV Ot� % Current Renewables Engineering Inc. Professional Engineer projects @creng. solar 196() 9 5 1, 2 54,5, N 11', C',`4\UTY tl\",\,���,,�')F,-n'S,ea �""",�t\�",\"",�,,�,.,,,St,,<t 0JST0-PVVFR Job Code: JUANK8A@AUTOU urrent Renewables Engineering RnofType= Roof Pitch (deB)= Mean Roof Height (ft)= Attachment TribWidth (ft) = Attachment Spacing (ft)= rrmnoog Tywe= Framing Size= r Framing OCSpacing (inj= Section Thicknessb (in.) = ` Section Depth, d (in.) = Section Modulus, Sx(in.^3) = Moment ofInertia, |x(in.^4)= Framing Span (t) = Deflection Limit D+L(ipj= Deflection Limit SoryV(in.) = Framing Upgrade = Sister Size = Wood Species = Wood Fb(po|)= Wood Fv(pd)= Wood E(p^)= Co(VVind)= CD(Sn �)= CM=Ct=[L=Ci= Cr= C*= Cr= Pb_wind(pmi)= F'b_snow (psi) = F'v wind(pmU= F'v_snow (psi) = K8_aUowab|e_vvind(}b4ft)= M_e!Iowa b|e_snow(|b~ft)= V_aU Ne wind (|bo) = V_a|lovvable snow(|ba)= E' (psi) = Job Code: ]UANMANAUTOU Current 3 of 6 Renewables Engineering Panels Dead Load (psf) = 10 Roof 1 Roofing VVeight(psf) = 3.0 Decking Weight (ps0= 2.8 Framing Weight (pmh = 0.6 Misc. Additional Weight (�f)= 1�0 � Existing Dead Load ( = 6.6 Wind Load Calculations: Ultimate Wind = 145 Directionality Factor, hd= 0.85 Topographic Factor, kzt= 1�0 Roof 1 Velocity Press Exp Factor, kz= 0.85 Ground Elevation Factor, ke= 1.00 Velocity Pressure, qz(ps )= 3&8 Array Edge Factor, yE= 1�25 Solar Equalization Factor, ya= 030 External Pressure Up, 5[p_l= -1.5 External Pressure Up, GCp_2= 2.2 External Pressure Up, GCp_3= '23 External Pressure Down, GCp= 0.6 Design Pressure Up, p_1 (psf) = -51.0 Design Pressure Up, p_Z (psf)= '74�8 Design Pressure Up, p_3 (pmf)= -78.2 Design Pressure Down, p(psf)= 20.4 Roof Ref. VVidthrawa|Ve|ue, VV (lb/in) = 266 (CM =Ct={e«=I-O)C»= 1�6 Adjusted VVidthrmwm|Va|ue, VV' (|b/in) = 426 Lag Penetration, p(in.)= 2.5 Allowable VVidthrawa|Force, VV'p(|bu)= 1064 Applied Uplift Force (|bs)= -462 Uplift DCR= 0,43 111,11-1-,�,, A��� ��AIV "I~������� R V, P E f"' II t,� N (" x", Job Code: JUAN MANAUTOU Current 4of6 R a;,ltis n ew1 - � nc esEngineering x Ref. Lateral Value, Z (lbs) = 270 (CM =Ct=CA=Ce8=1.0)CD= 0.9 Adjusted Lateral Value, Z' (lbs) = 243 Applied Laeral Force (Ibs) = 15 Angle of Resultant Force, o (deg) = 63 djusted Interaction Lateral Value, Z',, (Ibs) = 1060 Lateral DCR = 0.01 Roof Fr mi Checks; Force Checks: Roof 1 LC1: D+ Applied Moment (lb-ft) = 58 Applied Shear (Ibs) = 58 Allowable Moment (lb-ft) = 524 Allowable Shur (Ibs) = 725 Moment DCR = 0.11, Shear DCR = 0.08 LC2: D+0:6W Applied Moment (lb-ft) = 11 Applied Shear (Ibs) = 131 Allowable Moment (lb-ft) = 729 Allowable Shear (Ibs) = 1008 Moment DCR = 0«1 Shear DCR = 0.1 LC3 D+0.75(S+0.6W) Applied Moment (lb-ft) = 113 Applied Shear (Ibs) = 113 Allowable Moment (lb-ft) = 729 Allowable Shear (Ibs) = 1008 Moment DCR = 0.15 Shear DCR = 0.11 LC4: 0.6D+0:6W Applied [moment (lb-ft) = 149 Applied Shear (Ibs) = 19 Allowable Moment (lb-ft) = 729 Allowable Shear (Ibs) = 1003 Moment DCR = 0.20 Shear DCR = 0.15 ,' .. �,z, ,,.1 .' P r"'O . 10", ,' Ak,t��'A 1 P..`;ii�t`t ip,34.,F ,..,�PER)t, .<,. a. Current Renewables 'Engineering Deflection Check, (cArvirp I Roof UCl:D+L Deflection (inj= 0.02 Deflection Limit (inj= 138 Deflection DCR= 0.01 LC2/S Deflection (in.)= <lOO Deflection Limit (in.)= O.92 Deflection DrR= 0.00 LC3:VV(Down) Deflection (in.) = 0.01 Deflection Limit (in.)= K92 Deflection DCR= 0\01 LC4:VV(Up) Deflection (in.) = -0.03 Deflection Limit (|nj= 0i9I Deflection = 0J03 M-- Wall Weight () = 17 Tributary Wall Area (ft)= IOOO Total Wall Weight (|bm)= �)= 17000 Roof Weight (p 7 Roof Area (ft)= 2400 Total Roof Weight (|bs)= 15844 Total Existing Weight Ubs = 32844 Total Additional PVWeight (!bm)= 926 Weiaht Increase: Job Code: JUA@&1A0AUTOU The increase Ynweight msaresult ufthe solar system is less than l0%ofthe existing structure and ' therefore nofurther seismic analysis is required. g Job Code: JUAN MANAUTOU Current 6 of 6 Re1�. ,; paxw a ba es Engineering time of erection, and assumed to have appropriate permits. The calculations produced are only for the roof framing supporting the proposed PV installations referenced in the stamped planset and were completed according to generally recognized structural analysis standards and procedures, professional engineering and design experience, opinions and judgements. Existing deficiencies which are unknown or were not observable during time of inspection are not included in this scope of work. All PV modules, racking, and mounting equipment shall be designed and installed per manufacturer's approved installation specifications. The Engineer of Record and the engineering consulting firm assume no responsibility for misuse or improper installation. This analysis is not stamped for water leakage. Framing was determined based on information in provided plans and/or photos, along with engineering judgement. Prior to commencement of work, the contractor shall verify the framing sizes, spacings, and " spans noted in the stamped plans, calculations, and cert letter (where applicable) and notify the Engineer of Record of any discrepancies prior to starting construction, Contractor shall also verify that there is no damaged framing that was not addressed in stamped plans, calculations, and cert letter (where applicable) and notify the Engineer of Record of any concerns prior to starting construction. ��, ` ,"l lntiaCA�.., a.ca`- Freedom Forever 2010 51 st Ave E #111, Palmetto, FL 34221, USA Attn, CITY OF ZEPHYRHILLS: 6/30/2022 REV #1 The changes outlined in Revision Details have been applied to the plans corresponding to the following customer: JUAN MANAUTOU 6214 SILVER OAKS DRIVE, ZEPHYRHILLS, FL 33542 Revision stalk® 1. POI changed to Line side tap inside existing MSP, TLD revised (page PV-4) All corresponding changes are notated on the plans by revision clouds. Thank you for your time in reviewing these plans. Please reach out if you have any additional questions or concerns. Construction Engineering Freedom Forever N"-, Mc __1 M­_� CODES: CONSTRUCTION NOTES: � THIS PROJECT COMPLIES WITH THE FOLLOWING; 2020 7TH EDITION FLORIDA BUILDING CODE: BUILDING CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND 2020 7TH EDITION FLORIDA BUILDING CODE: RESIDENTIAL ARE NOT MEANT TO LIMIT UP -SIZING AS REQUIRED BY FIELD CONDITIONS, 2020 7TH EDITION FLORIDA BUILDING CODE: MECHANICAL ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE MAXIMUM EXTENT 2020 7TH EDITION FLORIDA BUILDING CODE: PLUMBING POSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR TO THE SURFACE UPON WHICH THEY ARE x 2020 7TH EDITION FLORIDA BUILDING CODE. FUEL GAS MOUNTED. 2020 7TH EDITION FLORIDA BUILDING CODE: ENERGY CONSERVATION ��� MODULES SHALL BE TESTED, LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION IN - 2020 7TH I EDITION FLORIDA BUILDING CODE; EXISTING BUILDING ACCORDANCE WITH UL 2703. AND CARBON MONOXIDE ALARMS ARE REQUIRED , 850 Y. 2420 7TH EDITION FLORIDA BUILDING CODE: ACCESSIBILITY SMOKE PER SECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD, 2020 7TH EDITION FLORIDA FIRE PREVENTION CODE (NFPA) 2017 NATIONAL ELECTRIC CODE (NEC) DIG ALERT (811) TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY PRIOR TO ANY � n AS ADOPTED BY CITY OF ZEPiYRHILLS EXCAVATION TAKING PLACE PHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT FAIN SERVICE FROM Q) ._ DC DISCONNECTfINVERTER AS PER 2017 NEC SEC 250.166(A). -x � x SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF ART. 690 OF THE 2017 NEC VICINITY Pa THE MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROD OR LIFER � 1t22 EXP; 2128/23 UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEM SOLAREDGE OPTIMIZERS ARE LISTED TO IEC 62109-1 (CLASS II SAFETY) AND UL 1741 STANDARDS CLIENT: 11 JUAN MANAUTOU INSTALL. CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUIT 6214 SILVER OAKS DRIVE, ZEPNYRNILLS, FL ATTACHED TO THE ROOF USING CONDUIT MOUNT. 33542 AHJ: CITY OF ZEPHYRHlLLS 1, Prior to commencement of work, the contractor shall Verify the framing sizes, UTILITY: DUKE ENERGY (FL) spacings, and spans noted in the stamped glans and accompanying calculations PHONE: 8134698556 and notify the Engineer of Record of any discrepancies prior to starting construction, Zi v 2_. These plans are stamped for structural code compliance of the roof ¢raming supporting the proposed PV installation referenced only. These plans are not �V stamped for water leakage, PV modules, racking, and attachment components SYSTEM: must folfow anufacturer uide€manes and rer uirements. 9 ` SYSTEM SIZE (DC): 17 X 415 = 7.055 kW 3. Please See accompanying Structural Calculations report for details regarding SYSTEM SIZE (AC): 5.000 kW @ 240V Malc3uiatio ns as well as limits of scope of work and liability. MODULES: 17 X CANADIAN SOLAR: CS3N-415MS 1 THIS SYSTEM IS DESIGNED FOR OPTIMIZERS: 17 X SOLAREDGE S440 INVERTER: SOLAREDGE SE500OH-US [S!1] WIND SPEED: 145 MPH CATEGORY C EXPOSURE NOTE TO INSTALLERS: VERIFY THE ROOF FRAMING INFO BEFORE INSTALLATION AND NOTIFY THE FOR IF THERE IS ANY SITE LOCATION INCONSISTENCY BETWEEN SITE VERIFICATION AND THE TABLE OF CONTENTS: FOLLOWING: 2x4 TRUSS @ 24" OO SPACING WITH MAX UNSUPPORTED SPAN EQUAL TO OR LEES THAN 6 FT, PV-1 SITE LOCATION -- REVISIONS PV-2 SITE PLAN NO.. REVISEC7 BY DATE PV-2A ROOF PLAN WITH MODULES LAYOUT ""12022 PV-2B STRUCTURAL CALCULATIONS _-- — 1=--- PV-3 MOUNTING DETAILS freedom PV-4 THREE LINE DIAGRAM PV-5 CONDUCTOR CALCULATIONSFREEDOM FOREVER LLC 2619 CONSULATE DR SUITE 800, ORLANDO, PV-6 EQUIPMENT & SERVICE LIST FL 32819 Tel 180€) 385-1075 PV-7 LABELS DREG ALBRlGHT PV-7A SITE PLACARD, PV-8 OPTIMIZER CHART /4 PV-9 SAFETY PLAN CONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR PV-10 SAFETY PLAN EC13008056 APPENDIX MANUFACTURER SPECIFICATION SHEETS SITE LOCATION JOB Nd r DA ET DESlGNEfl BY: SHEET: 230674 1 6/30/2022 1 A.M, PV-1 LEGEND: BOS WILL BE AS CLOSE AS POSSIBLE TO MSP WITHIN 10' THIS SYSTEM DESIGNED WITH: - OBSTRUCTION WIND SPEED, 145 PIPE VENT MODULES CONDUIT SETBACK HAC DISCONNECT Fs P] MSP JUNCTION BOX Iv INVERTER PRODUCTION Fml METER PV SYSTEM 7.055 kW -DC 5000 kW AC (E) MAIN SERVICE PANEL (IN GAR/ (E) UTILITY ME (N) AC DISCONNECT Ed (c (N) SOLAREDGE,' INVERTER WITH RA (NI (N) 17 CANADIAN SOLI 1� SITE PLAN PROPERTY LINE Stamped: 1/1122 EXP: 2/28/23 I ROOF AREA: 3089 SQ FT CLIENT: JUAN MANAUTOU 6214 SILVER OAKS DRIVE, ZEPHYRHILLS, FL 33542 AHJ: CITY OF ZEPHYRHILLS UTILITY: DUKE ENERGY (FL) PHONE: 8134698556 SYSTEM SIZE (DC): 17 X 415 = 7.055 kW SYSTEM SIZE (AC): 5.000 kW @ 240V MODULES: 17 X CANADIAN SOLAR: CS3N-415MS OPTIMIZERS: 17 X SOLAREDGE S440 INVERTER: SOLAREDGE SE500OH-US [Sill REVISIONS REVISED BY DATE A.M. 6/30/2022 freedom F 0 R, E, v FREEDOM FOREVER LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 GREG ALBRIGHT a' A I tA 1 u'J' — CONTRACTOR LICENSE CERTIFIED ELECTRICAL CONTRACTOR EC13008056 SCALE 1/16" ® V-0" SITE PLAN 1 JOB NO: DATE- I DESIGNED By I SHEET 230674 I 1/3112122 A_M_ I MODIFIED SETBACKS PROPOSED AT RIDGE: ILEGEND: I OBSTRUCTION 0 PIPE VENT MODULES CONDUIT SETBACK ac 17-1 AC DISCONNECT MSP JUNCTION BOX Ilav INVERTER PRODUCTION METER PV SYSTEM 7,055 kW -DC: 5.000 kW -AC TOTAL ARRAY AREA = 372.13 SF TOTAL ROOF AREA = 3089 SF TOTAL ARRAY AREA AS A % TO ROOF AREA = 12.05% 12.05% < 33% BOS WILL BE AS CLOSE AS POSSIBLE TO MSP WITHIN 1, THIS SYSTEM DESIGNED WITH: WIND SPEED: 145 LAYOUT SUBJECT TO CHANGE (E) UTILITY METEF z dk E;N 4,1 3 No, f/3,500 IROOF AREA: 3089 SQ FT CLIENT: JUAN MANAUTOU :ESS 6214 SILVER OAKS DRIVE, ZEPHYRHILLS, FL 33542 (S AHJ: CITY OF ZEPHYRHILLS UTILITY: DUKE ENERGY (FL) PHONE: 8134698556 SYSTEM: SYSTEM SIZE (DC): 17 X 415 = 7,055 kW SYSTEM SIZE (AC): 5.000 kW @ 240V MODULES: 17 X CANADIAN SOLAR: CS3N-415MS OPTIMIZERS, 17 X SOLAREDGE S440 INVERTER: SOLAREDGE SE500OH-US [Sill REVISED BY DATE A.M. -----T-6/3M2022 freedom FREEDOM FOREVER LLC 2619 CONSULATE DR SUITE 800. ORLANDO, FL 32819 Tel: (800) 385-1075 GREG ALBRIGHT - Ij CONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 ROOF PLAN NOTES: 1. EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNTS SCALE: 3/32" ® 1 2. ATTACHED CLAMPS AT 25% FROM THE EDGE AND 50% FROM THE CENTER OF THE MODULES ROOF PLAN WITH MODULES LAYOUT 3. JUNCTION BOX IS MOUNTED TO THE RAIL. JOB NO: DATE: DESIGNED BY: SHEET 230674 6/30/2022 R.M. PV-2A ARRAY FLOOR PLAN WITH MODULES LAYOUT Scale- NTS NOTE TO INSTALLERS: VERIFY THE ROOF FRAMING INFO BEFORE INSTALLATION AND NOTIFY THE EOR IF THERE IS ANY INCONSISTENCY BETWEEN SITE VERIFICATION AND THE FOLLOWING: 2x4 TRUSS @ 24" OC SPACING WITH MAX UNSUPPORTED SPAN EQUAL TO OR LESS THAN 6 FT, CANADIAN SOLAR: CS3N-415MS TRIMRAIL SLIDER AND TRIMRAIL ROOF ATTACHMENT FLASHING S/16" STAINLESS STEEL LAG BOLT OR STRUCTURAL SCREW WITH 2-1/2" MIN. EMBEDMENT AND FLAT WASHER MICRORAIL 5' 01- PLASHING SLIDERS ROOF / DECK MEMBRANE 2X4 TRUSS @ 24'O.C. MAX ATTACHMENT SPAN - 4'STAGGERED TRIMRAIL CANADIAN SOLAR: CS3N-415MS SLIDER AND TRIMRAIL ROOF ATTACHMENT ROOF DECK MEMBRANE uffo STAINLESS STEEL LAG OR STRUCTURAL SCREV 12-1/2" MIN. EMBEDMEA FLAT WASHER BUILDING STRUCTURE 32M M*dulo (Raof Zones) FM Zxl'ty 3 sFf-j c*Mpanants. Mw Q Atnzach-mn,;e�,, Mw If= IICRORAIL -ANADIAN SOLAR: :S3N-415MS ;LIDERS 9� /16" STAINLESS STEEL AD BOLT OR TRUCTURAL SCREW VITH 2-1/2" MIN. MBEDMENT AND FLAT MASHER M/22 EXP: 2128/23 JUAN MANAUTOU 6214 SILVER OAKS DRIVE, ZEPHYRHILLS, 33542 AHJ: CITY OF ZEPHYRHILLS UTILITY: DUKE ENERGY (FL) PHONE: 8134698556 SYSTEM: SYSTEM SIZE (DC): 17 X 415 = 7.055 kW SYSTEM SIZE (AC): 5.000 kW @ 240V MODULES: 17 X CANADIAN SOLAR: CS3N-415MS OPTIMIZERS: 17 X SOLAREDGE S440 INVERTER: SOLAREDGE SE500OH-US [SH] REVISED BY A.M. 6/3012022 freedom FREEDOM FOREVER LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 GREG ALBRIGHT CONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 SOLAR PV ARRAY SECTION VIEW ATTACHMENT DETAIL Scale- NTS Scale- NTS MOUNTING DETAILS JOB MC: I DATE: I DESIGNED BY I SHEET 230674 6/30/2022 A.M. PV-3 �B.ACKFEED BREAKER SIZING M � MAX, CONTINUOUS OUTPUT 21.00A @ 240V 21,00 X 1,25 = 26.25AMPS 30A BREAKER - OK SEE 705.12 OF 2017 NEC 150 X 1,20 = 180 180 - 150 = 30A ALLOWABLE BACKFEED PV SYSTEM 7,055 kW -DC 5.000 kWAC INTERCONNECTION METHOD SUBJECT TO CHANGE STRING-1 S3N-415MS(415VV) STRING-2 9 CANADIAN SOLAR CS3N-415MS4415N) I I L SOLAREDGE S440 — POWER OPTIMIZERS 2 - #10 AWG, PV WIRE 1 - #6 AWG IN FREE AIR OR #8 AWG MUST BE IN EMT CONDUIT SOLAREDGE S440 POVIER OPTIMIZERS 2-#IOAWG, PV WIRE M (N)SOLAREDGE SE500OH-US IS11 I INVERTER F�A7C 4 - #10 AWG, THWN-2 1 - #8 EGC, THWN-2 IN 3/4" OR LARGER EMT CONDUIT ---------- RAPID SHUTDOWN SWITCH _41 (N) 60A FUSED AC DISCONNECT EATON DG222NRB (OR EQUIVALENT) 2 - 30 AMP FUSES 3 - #10 AWG. THWN-2 I - #8 EGC, THWN-2 IN 3/4" OR LARGER EMT CONDUIT (E) 150A RATED MAIN SERVICE PANEL I PH, 120/240V 60HZ (E) 150A / 2P MAIN BREAKER (BOTTOM FED) EXP: 2/28/23 CLIENT: JUAN MANAUTOU (E) UTILITY 6214 SILVER OAKS DRIVE, ZEPHYRHILLS, F METER 33542 AHJ: CITY OF ZEPHYRHILLS UTILITY: DUKE ENERGY (FL) PHONE: 8134698556 (N) LINESIDE TAP VIA I LISTED CONNECTORS ■ --------------------- 3 - #6 AWG, THWN-2 IN 3/4" OR LARGER EMT CONDUIT 1 -#6 GEC, BARE COPPER FREE AIR BONDED EXISTING LIFER TIE IN A TAPBOX MAY BE USED IN LIEU OF PERFORMING THE LINESIDE TAP IN THE MAIN SERVICE PANEL. THIS IS DEPENDENT UPON SITE CONDITIONS- F-r-ONNECT TO EXISTING UFER SYSTEM: SYSTEM SIZE (DC): 17 X 415 = 7.055 kW SYSTEM SIZE (AC): 5,000 kW @ 240V MODULES: 17 X CANADIAN SOLAR: CS3N-415MS OPTIMIZERS: 17 X SOLAREDGE S440 INVERTER: SOLAREDGE SE500OH-US [Sill REVISIONS REVISED BY A.M. DATE 6/30/2022 % freedom FREEDOM FOREVER LLC 2619 CONSULATE DR SUITE 800. ORLANDO, FL 32819 Tel: (800) 385-1075 GREG ALBRIGHT CONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 NOTE: CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT THREE LINE DIAGRAM TO LIMIT UP -SIZING AS REQUIRED BY FIELD CONDITIONS JOB NO DATE, I DESIGNED BY: SHEET: M 230674 1.130/2022 A.M. PV-4 MODULE INFO MAKE/MODEL: CANADIAN SOLAR: CS3N-415MS Voc: 45.1 V Vmp: 37.8 V Isc: 11.68 A Imp: 10.98 A STC RATING: 415 W RTC RATING: 415 W MAX DC CURRENT: [max = 1.25 X (OPTIMIZER OUTPUT CURRENT) = 1.25 X 15 = 18.75A MAX AC CURRENT, Imax = 125 X (SUM OF MAX CONTINUOUS OUTPUT CURRENT FROM INVERTERS) = 1.25 X (21.00) = 26.25A WIRE SCHEDULE RACEWAY # EQUIPMENT WIRE LOCATION CONDUCTOR CITY, AWG WIRE SIZE STARTING ALLOWABLE AMPACITY @ 90°C 310A5(B)(16) STARTING CURRENT APPLIED TO CONDUCTORS IN RACEWAY TEMPERATURE CORRECTION FACTOR 310.15(B)(2)(a) ADJUSTMENT FACTOR FOR MORE THAN 3 CONDUCTORS 310.15(B)(3)(a) ADJUSTED CONDUCTOR AMPACITY @ 90-C MAXIMUM CURRENT APPLIED TO CONDUCTORS IN RACEWAY I DC MODULE TO OPTIMIZER ROOF / FREE -AIR 2 10 40 14.60 1 1 40,00 18,25 2 DO OPTIMIZER TO JUNCTION BOX ROOF / FREE -AIR 2 10 40 15.00 1 1 40,00 1&75 3 DC JUNCTION BOX TO INVERTER EXTERIOR WALL 4 10 40 15.00 1 0.8 32.00 1&75 4 AC INVERTER TO AC DISCONNECT EXTERIOR WALL 3 10 40 21,00 1 1 40.00 26.25 5 AC AC DISCONNECT TO POI EXTERIOR WALL 3 6 75 21.00 1 1 75.00 26.25 7/1/22 UP: 2/28/23 CLIENT: JUAN MANAUTOU 6214 SILVER OAKS DRIVE, ZEPHYRHILLS, FL 33542 AHJ: CITY OF ZEPHYRHILLS UTILITY: DUKE ENERGY (FL) PHONE: 8134698556 SYSTEM: SYSTEM SIZE (DC): 17 X 415 = 7.055 kW SYSTEM SIZE (AC): 5.000 kW @ 240V MODULES: 17 X CANADIAN SOLAR: CS3N-415MS OPTIMIZERS: 17 X SOLAREDGE S440 INVERTER: SOLAREDGE SE5000H-US [SH] REVISIONS wl 6/30/2022 freedom 0 P" z v E FREEDOM FOREVER LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 aREG ALBRIGHT V CONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 CONDUCTOR AMPACITY CALCULATIONS IN ACCORDANCE WITH NEC 690.8. 1 CONDUCTOR CALCULATIONS JOB NO: DATE. DESIGNED BY: SHEET 230674 6/30/2022 A.M. PV-5 FBREAKER SIZES: SERVICE LIST: NONE T�- ,: u„ r 07 ,� Jr sd l6. ✓.. Jry yh MATERIAL LIST: CITY. PART PART # DESCRIPTION 17 MODULES 116-415 CANADIAN SOLAR: CS3N-415MS 17 OPTtMIZERS S440 SOLAREDGE S440 POWER OPTIMIZER - FRAME MOUNTED MODULE ADD -ON Stamped: 711 2 EXP: 2t28123 i 1 JUNCTION BOX 480-276 60OVDC NEMA 3R UL LISTED JUNCTION BOX 2 CONNECTORS 240-300 STAUBLI / MULTI -CONTACT MC4 CONNECTORS (FEMALE) 2 CONNECTORS 240-301 STAUBLI / MULTI -CONTACT MC4 CONNECTORS (MALE) 1 INVERTER 120-501 SOLAREDGE SE500OH-US [Sill 240V INVERTER UL1741 SA CERTIFIED INTEGRATED ARC FAULT PROTECTION AND RAPID SHUTDOWN 1 AC DISCONNECT 323-061 60A RATED 240VAC NEMA 3R UL LISTED CLIENT: JUAN MANAUTOU 2 FUSES 330-030 30A FUSE 1 PH 240VAC 6214 SILVER OAKS DRIVE. ZEPHYRHILLS, FL 1 FUSE REDUCER 330-530 30A-60A FUSE REDUCER 33542 67 ROOF ATTACHMENT 1 261 -602 SFM INFINITY 1 ROCKIT MICRORAIL i AHJ: CITY OF ZEPHYRHILLS NUMBER PART TYPE OFSUTTUTILITY- DUKE ENERGY (FL) 13 SFM TRIM 1 241-253 FLASHKIT SFM J ROCK -IT TRIM COMP DARK PHONE: 8134698556 33 SFM SLIDER 1 261-603 FLASHKIT SFM / ROCK -IT SLIDER COMP DARK 10 BONDING CLAMP 1 221-100 N/S BONDING CLAMP 4 BONDING CLAMP 1 241-404 TRIM BONDING CLAMP 18 MOUNT ASSEMBLY 1 241-405 MLPE MOUNT ASSY 11 SFM SPLICE 1 261-604 SFM / ROCK -IT SPLICE SYSTEM: 3 SFM ATTACHED SPLICE 1 211-101 ATTACHED SPLICE 8INCH ` _ SYSTEM SIZE (DC): 17 X 415 = 7.055 kW SYSTEM SIZE (AC): 5.000kW @ 240V 14 TRIMRAIL 1 261-606 TRIMRAIL UNIV CLIP W/ HOW MODULES: 17 X CANADIAN SOLAR: 5 TRIM SPLICE 1 261-605 TRIM SPLICE DIRK CS3N-415MS OPTIMIZERS: 17 X SOLAREDGE S440 S TRIMRAIL 1 211-115 TRIMRAIL UNIV DIRK INVERTER: SOLAREDGE SE5000H-US [Sill 17 GROUND LUG 1 260-585 ILSCO GROUND LUG I 17 TRIM END CAPS 1 221-200 UNIRAC SFM / ROCK -IT TRIM END CAPS M> __4 ,, ' REVISIONS NO-1 REVISED BY DATE-- 1 A A E 6/30/2022 _ ,., S .L _,D.L. _ A freedom FREEDOM FOREVER LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 TeL (800) 385-1075 -' 1 GREG ALBRIGHT CONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 '2 , k EQUIPMENT & SERVICE LIST Eno 'A ..'_., A S u JOB NO: ': DATE: DESIGNED BY SHEET: 230674. 6/30/2022 A.M. PV-G 7- 690:54 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN kR PV SYSTEM EQUIPPED THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE HAND-WRITTEN. t fITH RAPID SHUTDOWN 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP -RIVETS OR SCREWS 3212�� __ 111mm- -.1 I INVERTER I I - 690. 13 (B) /1/22 EXP: 2/28/23 6214 SILVER OAKS DRIVE, ZEPHYRHILLS, 33542 AHJ: CITY OF ZEPHYRHILLS UTILITY: DUKE ENERGY (FL) PHONE: 8134698556 �SYSTEM; SYSTEM SIZE (DC): 17 X 415 = 7.055 kW SYSTEM SIZE (AC): 5,000 kW @ 240V MODULES: 17 X CANADIAN SOLAR: CS3N-415MS OPTIMIZERS: 17 X SOLAREDGE S440 INVERTER: SOLAREDGE SE500OH-US [Sill REVISIONS I NO. REVISED BY ! DATE 16/3012022 ---------- I I LABELS NFPA 1 t122tttl JOB NO: 1DATE DESIGNED BY I SHEET. 230674 . /30/2022L UTILITY METER --/ AC DISCONNECT INVERTER EQUIPPED --J \ \ / / WITH RAPID SHUTDOWN L 17 PV MODULES WARNING JUNCTION BOX TURN OFF PHOTOVOLTAIC AC DISCONNECT 1 . NEC ARTICLES 690 AND 705 AND FBC SECTION R324 MARKINGS SHOWN HEREON, 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO—PLATING. Be RED BACKGROUND COLOR WHITE TEXT AND LINE WORK. C. AERIAL FONT, 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE HAND—WRITTEN. 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP —RIVETS OR SCREWS. 7/1/22,FXP: 2/28/23 �CLIENT: JUAN MANAUTOU 6214 SILVER OAKS DRIVE, ZEPHYRHILLS, 33542 AHJ: CITY OF ZEPHYRHILLS UTILITY: DUKE ENERGY (FL) PHONE: 8134698556 SYSTEM: SYSTEM SIZE (DC): 17 X 415 = 7.055 kW SYSTEM SIZE (AC): 5.000 kW @ 240V MODULES: 17 X CANADIAN SOLAR: CS3N-415MS OPTIMIZERS: 17 X SOLAREDGE S440 INVERTER: SOLAREDGE SE500OH-US [SI1] I NO. I REVISED BY I DATE I 1 1 1 A.M. 16/30/2022 1 freedom 0 R E 11 E R FREEDOM FOREVER LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 DREG ALBRIGHT CONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 SITE, PLACARD JOB NOi . 1ATE: I DESIGNED BY: SHEET: 230674 /D30/2022 A.M_ I PV-7A SAFETY PLAN MARK UP KEY INSTRUCTIONS: t USE SYMBOLS IN KEY TO MARK UP THIS SHEET. PERMANENT ANCHOR 2. SAFETY PLAN MIST BE MARKED BEFORE JOB STARTS AS PART OF THE PRE -PLAN 1 DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE TEMPORARY NCHOR & MAKE NOTES CAI THE JHA SHEET IN CASE OF EMERGENCY FL] INSTALLER LADDER NEAREST HOSPITAL OR OCCUPATIONAL/INDUSTRIAL CLINIC ���� JUNCTION / COMBINER BOX NAME: 0 STUB -OUT ADDRESS: SKYLIGHT SAFETY COACH CONTACT INFORMATION NO LADDER ACCESS (STEEP CLIENT: NAME: JUAN MANAUTOU GRADE DE OR GROUND D LEVEL 6 6214 SILVER OAKS DRIVE, ZEPHYRHiLLS, FL y t 9Ld6J V 1® 33542 PIICCTi�IE NUMBER: % OBSTRUCTIONS) AHJ:CITYOFZEPHYRHILLS UTILITY: DUKE ENERGY (FL) PHONE: 3134698556 ALL EMPLOYEES CAI SITE HALL BE MADE AWARE OF THE RESTRICTED ACCESS SAFETY PLAN AND SIGN INDICATING THAT THEY ARE AWARE OF THE HAZARDS ON -SITE AND THE PLAN FOR WORKING SAFELY. - -.- - C�l�1T SYSTEM: \\ �� SYSTEM SIZE (DC): 17 X 415 = 7,055 kW NAME SIGNATURE �: SYSTEM SIZE (AC): 5.000 kW @i 240V MODULES. 17 X CANADIAN SOLARr SAS GAS SHUT OFF OPTI I15MS 17 X SOLAREDGE 5440 INVERTER: SOLAREDGE SE500OH-US (Sill 20 WATER SHUT OFF ISERVICE DROP POWER LINES --- REVISIONS NO. REVISED BY _DATE 1 'A.M.-6130/2022 freedom FREEDOM FOREVER LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 MATE: TIME: GREG ALBRIGHT ry CONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 SAFETY PLAN JOB NO: I DATE: DESIGNED BY: SHEET: 230674 1 6/30/2022 AM. PV-9 JOB HAZARD ANALYSIS Crew leader to fill out all sections below, hold a pre -job safety meeting with all personnel, and upload this completed document and the Safety Plan to Site Capture Ladder Access 0 Ladders must be inspected before each use. Extension ladders must be set up on a firm and level surface at a 4-to-1 rise to run angle (or 75 degrees) and the top must be secured to the structure, Extension style ladders placed on uneven, loose or slippery surfaces must additionally have the base firmly anchored or lashed so the base will not slip out. Extension ladders must be used with walk-through devices or the ladder must extend 36" above the stepping off point. A -frame ladders must only be climbed with the ladder spreader bars locked in the open position; A -frame ladders shall not be climbed while in the closed position (ex, closed and used while leaned against a structure). Additional notes: Mobile Equipment Only Qualified operators will operate equipment" operators must maintain a certification on their person for the equipment being operated. 0 Type(s) of mobile equipment (Type/Make/Model): Crew leader responsible for communication with the client.- Heat Related Illness Prevention NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE 0 Employees shall have access to potable drinking water that is (add as many as necessary by using additional sheets) Client and public is excluded from work area by barricades (N/A, fresh,pure, and suitably cool. The water shall be located as Yes, No): close as practicable to the areas where employees are working. Define the Hazard: Method/steps to prevent incident: Water shall be supplied in sufficient quantity at the beginning of Training and Pre -Job Safety Briefing the work shift to provide at least one quart per employee per All employees onsite shall be made aware of the specific hazards hour for drinking for the entire shift. Employees may begin the of this project and review this HJA during a pre job briefing, and shift with smaller quantities of water if they identify the location Define the Hazard: Method/steps to prevent incident,- their signature indicates awareness of site conditions and the and have effective means for replenishment during the shift to plan to eliminate any hazards identified prior to and during the allow employees to drink on quart or more per hour. The project. frequent drinking of water shall be encouraged, 0 Shade shall be present when temperature exceeds 80 degrees Crew leader (name/title): Fahrenheit. When the outdoor temperature in the work exceeds Define the Hazard-, Method/steps to prevent incident: 80 degrees Fahrenheit, employees shall have and maintain one Crew member (name/title): or more areas with shade at all times. - New employees must be acclimatized. New employees will be Crew member (name/title): monitored by their Crew Leader (site supervisor) for the first two (2) weeks of employment or longer when necessary. Define the Hazard: Method/steps to prevent incident: Crew member (name/title): a Employees will be allowed and encouraged to implement scheduled breaks during each shift. Employees must take Crew member (nameltitle): I* cool -down breaks in the shade any time they feel the need to do I Qualified operator(s): so to protect them from overheating. Supervisors are I Crew member (narrie/title): REQUIRED to allow employees any break period they need Material Handling and ,�a a 1 1 during high heat conditions, CLIENT: JUAN MANAUTOU Materials will be staged/stored in a way that does not present a Airborne Contaminants: 0 Cool Vests are encouraged for all employees at all times during 6214 SILVER OAKS DRIVE, ZEPHYRHILL,' hazard to client, personnel or public. Materials stored on the 0 Asbestos -containing (Transite) piping (ACP) - Do not disturb periods of high heat. 33542 roof will be physically protect from failing or sliding off, (move, drill, cut fracture, etc,) 0 Identify the location of the closet Occupational/industrial Clinic AHJ: CITY OF ZEPHYRHILLS UTILITY: DUKE ENERGY (FL) ® Asbestos -containing thermal insulation (ACI) and or Hospital in case a crew member becomes ill. PHONE: 8134698556 Fall Protection A site -specific plan for fall prevention and protection is required prior to starting work and must remain onsite at all times until work is complete; a fall rescue plan must be outlined and discussed among the crew prior to work start. First -person -Up (FPU) must install their anchor and connect before any other task, including installing other anchors. The Last -Person -Down (LPD) must be the only person on a roof uninstalling fall protection, FPCP (name and title): FPU and LPD (name and title): Electrical Saf ety ® The Electrical Qualified Person (EQP) is required onsite to perform electrical work. * All electrical work will be performed with equipment in an electrically safe condition (de -energized) unless approval has been granted prior to work. * Service drops and overhead electrical hazards will be indentified and protected from contact, as neccessary. EQP (name and tile). - Public Protection • The safety of the Client and Public must be maintained at all times, ® The Client and the Public shall be prevented from entering the work zone through the use of barriers and/or signage, as required. ® Company, Client and Public property shall be protected from failing objects, • Pets (including dogs) shall be secured by their owners prior to work start, • The Client should not leave pets, family members, or others in charge or care of Employees, Contractors, or Temporary Workers. Asbestos -containing duct wrapping (ACW) - do not disturb, no attic or crawlspace access is allowed if work to be performed could cause exposure to personnel, client or public. Weather and Environment • The site supervisor shall forecast the weather conditions at the job site, prior to crew arrival, in order to mitigate any hazards associated with inclement weather (heat, cold, wind, rain, etc,) • The site supervisor will utilized a portable wind meter (anemometer) to verify actual onsite wind conditions, by checking at the ground and on any elevated work surface (ex, rooftop) prior to work start, at midday and prior to solar panel staging on a roof. • Elevated work involving the moving or maneuvering of solar panels shall cease at 25mph (sustained wind) until wind subsides. * Forecasted weather maximum temp (degrees What is the specific plan to provide and replenish sufficient water for all emDlovees onsite? If offsite replenish is necessary, where will you go to replenish water (location/address): Who will replenish the drinking water (name): Restroorn facilities * Employees shall have access to restroom facilities with hand -washing stations. Use of onsite restroom is at the client's discretion (location is annotated below), If client does not give permission, location of suitable restroom facilities with hand -washing stations offsite will be provided. The onsite supervisor will identify location and make arrangements to ensure all employees have access at any point. * restroom facilities will be (circle one): Onsite - Offsite * If Offisite, add location name and addres& Incident Reporting Procedure Contact your Site Supervisor Name: Phone: Contact your Manager Name: Phone: a Contact your Site Supervisor Name: Phone: With: Your full name, phone number, office location, brief description of what happen and when. Mono PERC 400 W - 425 W CS3N-4001405'1 15 15 MERNEREM Module power up to 425 W Module efficiency up to 20.9 % Lower LCOE & BOS cost Comprehensive LID J LeTID mitigation -"N technology, up to 50% lower degradation Better shading tolerance Minimizes micro -crack impacts Heavy snow load LID to 5400 Pa, f enhanced wind load up to 2400 Pa* For detailed information, please refer to the installation Manuai. Canadian! 25 Industry Leading Product Warranty on Materials years and Workmanship* 2-5 Linear Power Performance Warranty* Years 111 year power degradation no more than 2% Subsequent annual power degradation no more than 0.55% *Subject to the terms and conditions contained in the applicable Canadian Solar Limited Warranty Statement. Also this 25 year limited product warranty is available only for products installed and operating on residential rooftops in certain regions. MANAGEMENT SYSTEM CERTIFICATES* ISO 9001: 20151 Quality management system ISO 14001: 2015 / Standards for environmental management system ISO 45001: 2018 / International standards for occupational health & safety PRODUCT CERTIFICATES* IEC 61215 / IEC 617301 CE FSEC (US Florida) UL 61730 / IEC 61701 1 IEC 62716 UNI 9177 Reaction to Fire: Class 1 / Take-e-way F ovc AcousiC ( CUD IWEE 99 The specific certificates applicable to different module types and markets will vary, and therefore not all of the certifications listed herein will simultaneously apply to the products you order or use. Please contact your local Canadian Solar sales representative to confirm the specific certificates available for your Product and applicable in the regions in which the products will be used. CANADIAN SOLAR (USA), INC. is committed to providing high quality solar products, solar system solutions and services to customers around the world, Canadian Solar was recognized as the No. I module supplier for quality and performance/price ratio in the IHS Module Customer Insight Survey, and is a leading PV project developer and manufacturer of solar modules, with over 55 GW deployed around the world since 2001 ENGINEERING DRAWING (MM) CS3N-41OMS 1-V CURVES R, wr V�evv A 12 A 12 180 A -A 3-6 11 is 10 35 25 \e-14X9 m unclog on f Un 7 6 7 6 on 4 4 3 3 2 Mu, n t Ho'r, I 0 v1_ v P. 5 10 15 20 25 30 35 40 -5 50 55 60 5 10 15 20 25 30 35 41 15 so 55 so 0 1 goo W/m' F"c 0/0 goo arm, 25'C a 60OW/m' 45'C 400 W/1' 65°C is ELECTRICAL DATA STC* MECHANICAL DATA CS3N 40MIM"s 40-5Al NOMS E 420MS 4251r, 5 E-1 Specificatkim Data Nominal Max. Power (Pmax) 400W 405W 410W 415W 420W 425W Cell Type Mono -crystalline Opt. Operating Voltage (Vmp) 37.2 V 37AV 37.6V 37.8V 38.0V 38.2V Cell Arrangement 132[2X(I1 X6)] Opt, Operating Current (Imp) 10,76 A 10.83 A 10.92 A 10.98 A 11.06 A 11.13 A 1940 X 1048 X 35 mm Dimensions Open Circuit Voltage (Vac) 44.5 V 44,7 V 44,9 V 45.1 V 453 V 453 V (76.4 X 41.3 X 1.38 in) Short Circuit Current (Isc) 11.50 A 11.56 A 11,62 A 11,68 A 11.74 A 11.80 A Weight 22.5 kg (49.6 lbs) Module Efficiency 19.7% 19,9% 20.2% 20A% 20.7% 20.9% Front Cover 3.2 mm tempered glass Operating Temperature -40'C - +85'C Frame Anodized aluminium alloy Max. System Voltage 1500V (IEC/UL) or 1000V (IEC/UL) J-Box IP68, 3 bypass diodes Module Fire Performance TYPE 1 (UL 61730 150OV) or TYPE 2 (UL 61730 Cable 4 mm' (IEC), 12 AWG (UL) 1 OOOV) or CLASS C (IEC 61730) Portrait: 400 mm (15.7 in) (+) 1280 Cable Length mm (11.0 in) (-) (supply additional Max. Series Fuse Rating 20 A (Including Connector) cable jumper: 2 lines/pallet); land - Application Classification Class A scape: 1250 mm (49,2 in)* Power Tolerance 0 - + 10 W Connector T4 series or MC4 I I Under Standard rest Conditions (STC) cif irradiance of 1000WIml, spectrum AM 1.5 and cell tempera Per Pallet 30 pieces ture of 25'C. Per Container (40' HQ) 720 pieces * For detailed information, please contact your local Canadian Solar sales and technical representatives. ELECTRICAL DA,,TA I NMOT* CS3N 400NIS 40 MS „1, 0 fMl S 4 15 f,,fi, S 4 2 0 1`0115, 4290 S Nominal Max. Power (Pmax) 300 W 304 W 308 W 311 W 315 W 319 W TEMPERATURE CHARACTERISTICS Opt. Operating Voltage (Vmp) 34.9 V 35,1 V 35.2 V 35.4 V 35,6 V 35,8 V Specificailor", Data Opt. Operating Current (Imp) 8.60 A 8.66 A 8.73 A 8.78 A 8.84 A &90 A Temperature Coefficient (Pmax) -0.34 % / *C Open Circuit Voltage {Vac) 42.1 V 42.3 V 424 V 42.6 V 42.8 V 43.0 V Temperature Coefficient (Voc) -026 % / 'C Short Circuit Current (Isc) 9.27 A 9.32 A 937 A 9,42 A 9.47 A 931 A Temperature Coefficient (Isc) 0.05 % / 1C * Under Nominal Module Operating Temperature (NM07), irradiance of800 W/nn7 spectrum AM1.5, Nominal Module Operating Temperature 41 ± 3'C ambient temperature 20'C, wind speed 1 mrs. The specifications and key features contained in this clatashert may deviate slightly from our actual products due to the on -going innovation and product enhancement. CS1 Solar Co., Ltd. reserves the right to make necessary adjustment to the information described herein at any time without further notice. Please be kindly advised that Fry modules should be handled and installed by qualified people who have professional skills and please carefully read the safety and installation instructions before using our PV modules. PARTNER SECTION CANADIAN SOLAR (USA), INC. CANADIAN SOLAR (USA), INC. July 2021 1 All rights reserved I PV Module Datasheet v2.9C25_F30J1_NA 3000 Oak Road, Suite 400, Walnut Creek, CA 94597, USA I www.csisolar.com/na I service.ca @csisolar.com PV power optimization at the module level I Specifically designed to work with SolarEdge residential inverters I Detects abnormal PV connector behavior preventing potential safety issues* I Module -level voltage shutdown for installer and firefighter safety I Superior efficiency (99,5%) I Mitigates all types of module mismatch loss, from manufacturing tolerance to partial shading I Faster installations with simplified cable management and easy assembly using a single bolt I Flexible system design for maximum space utilization I Compatible with bifacial PV modules Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Shutdown System (PVRSS) solaredge.com Power Optimizer For North America S440,S500 EM DC --owe x 4"- Aosc)", Max ­'t' 'D I Vo :VJ':, V; ')of-,-,, rc vaX - ­0 1 V V"c_ o15 VaX W A 98 E OUTPUT DURING OPERATION vax OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) SaVy, 0a„p per Pov/e, V;y STANDARD COMPLIANCE V,gar.3 s cl, 6 6' 00 V A INSTALLATION SPECIFICATIONS VaX ­_ A;,S­ Sys'e­ Vc 'aoc x x A X A W 7 4, vp v- ij C J T`3 C11— V,, o Vj- (r"­ Sg 'Do 1 �1, A ieA' 1-C -'a'X :c vo� 4 So a,119, --I, Ai'l .,igd SO'. ARi i ti,, 5.1dg,, o9o, OP I VHZ I D BY SOLARHX, i A, t s—'Ld- 1-1-1'9101, i,, Ad ..he, vde,,, I, e­ — o I ­r, r,,pe­,,, o e s 0m, Febrja,/8 7O)z DS WOUIR NA Su­t to 0—co, wtn ­� ­­ RoHS Intertek singie Phase Inverter w ith HD-Mve Technology I Optimized installation with HD -Wave technology I Specifically designed to work with power optimizers I UL1741 SA certified, for CPUC Rule 21 grid compliance I Record -breaking 99% weighted efficiency I Small, lightweight, and easy to install both outdoors or indoors I Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp I Built-in module -level monitoring I Fixed voltage inverter for longer strings I Optional: Faster installations with built-in consumption metering (1% accuracy) and I Integrated arc fault protection and rapid shutdown production revenue grade metering (0,5% accuracy, for NEC 2014, NEC 2017 and NEC 2020 per article ANSI C12.20) 690.11 and 690-12 solaredge.com solar =@v z Single Phase Inverter with HD -Wave Technology for North America SE300OH-USJ SE380OH-US / SE500OH-US / SE600OH-US/ SE760OH-USJ SE1000OH-US / SE1140OH-US Single Phase Inverter with HD -Wave Technology for North America SE300OH-US SE380OH-US / SE500OH-US / SE600OH-US/ SE760OH-US SE1000OH-US / SE1140OH-US ADDITIONAL FEATURES — - - --- - - - - ---- --- - ------ -------------------------------- ----- --- - ... - ---- - STANDARD COMPLIANCE INSTALLATION SPECIFICATIONS How to Enable Consumption Monitoring By simply wiring current transformers through the inverter's existing AC conduits and connecting them to the service panel, homeowners will gain full insight into their household energy usage helping them to avoid high electricity bills Single phase inverter with HD -wave technology and built-in RGM and Service Panel consumption monitoring Afl­��-, SO_AREDGE �r,Sd,rE,1q­,0 0P­4VRFD B­,) 'LFH,' Ea;c,��,,,,�,,�o,,��,�,P,�d�!�,j�,,�,,,,,�'� �NG NAV S,bo, ­P'l ­�, 11,. RoHS pe. e a ton,com, Eaton general duty cartridge fuse safety switch DG222NRB UPC:782113144221 Dimensions- * Height: 14,37 IN * Length: 7.35 IN * Width- 8.4 IN Weight: 10 LB Notes:Maximurn hp ratings apply only when dual element fuses are used, 3-Phase hp rating shown is a grounded B phase rating, UL listed. Warranties- - Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first, Specifications: * Type: General duty, cartridge fused * Amperage Rating- 60A * Enclosure: NEMA 3R * Enclosure Material: Painted galvanized steel * Fuse Class Provision: Class H fuses * Fuse Configuration: Fusible with neutral * Number Of Poles: Two -pole * Number Of Wires: Three -wire * Product Category: General duty safety switch * Voltage Rating: 240V Supporting documents: * Eatons Volumie 2-Cornmercial Distr�bu."Joln * Eaton Specification,, Sheet - DG222NRB Certifications: - UL Listed Product compliance- No Data @ 2016 Eaton, All rights reserved, EcoFaste For InstaLLers, By Installeir ar The Rock|tsystemisthe |ndustry'spremierrail-less PVrackingsystem forcompos|don shing|e, ti|e, and me1a| roofs. Designed in cor�unct|onwiththe needsof installers, Rock|tquickly & easily installs withosingle tooi Fea'turinganeasy-to-pos|donaH,gnnnentslide and atop' down |eveUngsystem' Rock|tis |oQ|st|caUy inteUigentvv|th noneadtoship ortransport long rails, [ompot, ents-are available 'in ablack finish that como|ementsboth commen|a| and residential app||cat|ons,Conforms toULZ7O3 FEATURES & BENEFITS ' PatentedvijaterUa-Ntechno|ogy ' Fu|yintesrated bonding ^ Top) 'Umwn !eve Ungsystf-_m ' Nor-Lh�outhacUuerabiUty ' Sing|etoo| install ^ ` ` Composition Shingle Tile, Metal rxesleek nszaxsnrI nd acrs asan ao@nmeo��u/de rnrrxeenurea',ay rheskirl, end capgoesuouu|euu�yasa ykirtcoupxnl- dev|ceaeymeucaxy- SFM INFINITY w "UNIRAC a's fan BETTER SOLAR STARTS HERE Take your business to filhie nwxt level ivdit'll SFM INFINITY, UNIRAC's rail -loss PV rnounting system for flush nniount installatioln's on comp shirngle aind file roofs, An advanced 3rd gernerationi product platfonruii ill usee, by top solar conitractors natiori- ide, SFM INFINITY optimizes you"r operafloinis oni and off the roof, with approximately 40% less labor, 30% logistics savings, and 20% fewer roof, attachinnients than tradiflonnal r cki .fin i us8% omneow rD1 f - -iers prefer SFM INFINITY's aest'Ic 'lefis. solara, 7of hi SUPERIOR PERFORMANCE EASY INSTALLATION HOMEOWNER PREFERRED Enhance your business with two installs per day Pre -assembled components, 20% fewer roof attachments, Vlore than 4 out of -3 homeowners prefer SFM INFINITY'S and 30% less cost, and level array in seconds with post height adjustment. aesthetics over a leading rail brand, SFM INFINITY DESIGN GUIDELINES "OUNIRAC sign SIR BETTER SOLAR STARTS HERE W[die �,vou will see advanitages simiply frorin switching to SFM INFINITY, the, fdowing guid,elinies will help you to ri"de its bffitsaxifZele, DEFAULT TO LANDSCAPE N MIX MODULE ORIENTATIONS S F M SFM v :M CONSULT THE QUICK TIPS VIDEOS tj M �fiq SFM -//u;yirac.cem/`Sf M-Infinity' https. DESIGN IN U-BUILDER U oilder -B, S-M I�Nll�­,'_: , "_"In il�o-o',,,dic or 1,qp,� -iund idesign.unirac,com/ https-fl, Unirac The product covered by this report is the Sun Frame Micro Rail roof mounted Photovoltaic Rack Mounting System, This system is designed to provide bonding and grounding to photovoltaic modules. The mounting system employs anodized or mill finish aluminum brackets that are roof mounted using the slider, outlined in section 4 of this report. There are no rails within this product, whereas the 3" Micro Rail, Floating Splice, and 9" Attached Splice electrically bond the modules together forming the path to ground. The Micro Rails are installed onto the module frame by using a stainless steel bolt anodized with black oxide with a stainless type 300 bonding pin, torqued to 20 ft-lbs, retaining the modules to the bracket. The bonding pin of the Micro Rail when bolted and torqued, penetrate the anodized coating of the photovoltaic module frame to contact the metal, creating a bonded connection from module to module. The grounding of the entire system is intended to be in accordance with the latest edition of the National Electrical Code, including NEC 250: Grounding and Bonding, and NEC 690: Solar Photovoltaic Systems. Any local electrical codes must be adhered in addition to the national electrical codes, The Grounding Lug is secured to the photovoltaic module, torqued in accordance with the installation manual provided in this document. Other optional grounding includes the use of the Enphase UL2703 certified grounding system, which requires a minimum of 2 micro -inverters mounted to the same rail, and using the same engage cable. pJamalmm Report No. 102393982LAX-002 Page 3 of 107 Issued: 11 -Apr-2016 Unirac, Inc Revised: 20-Mar-2019 me Module Orientation: Portrait or Landscape Maximum Module Size: 17.98 ft' UL2703 Design Load Rating: 33 PSF Downward, 33 PSF Upward, 10 PSF Down -Slope Tested Loads - 50 psf/2400Pa Downward, 50psf/2400Pa Uplift, 15psf/720Pa Down Slope Trina TSM-255PD05,08 and Sunpower SPR-E20-327 used for Mechanical Loading Increased size ML test: Maximum Module Size: 22.3 ft' UL2703 Design Load Rating: 113 PSF Downward, 50 PSF Upward, 30 PSF Down -Slope LG355S2W-A5 used for Mechanical Loading test. Mounting configuration: Four mountings on each long side of panel with the longest span of Mounting configuration: Six mountings for two modules used with the maximum span of 74.5" Fire Class Resistance Rating-, - Class A for Steep Slope Applications when using Type I Modules. Can be installed at any interstitial gap. Installations must include Trim Rail, - Class A for Steep Slope Applications when using Type 2 Modules. Can be installed at any interstitial gap. Installations must include Trim Rail. - Class A Fire Rated for Low Slope applications with Type 1 or 2 listed photovoltaic modules. This system was evaluated with a 5" gap between the bottom of the module and the roof's surface See section 7.0 illustraction # I and la for a complete list of PV modules evaluated with these W ED 16 3 15 (20-Apr-1 7) Mandatory ED 16.3.15 (20-Apr-17) Mandatory intertek AUTHORIZATION TO MARK Total Qualft. Assured. This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report, This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. Applicant.- Unirac, Inc Manufacturer: Cixi Emeka Aluminum Co. Ltd No. 688 ChaoSheng Road Address.- 1411 Broadway Blvd NE Address; CW City Albuquerque, NM 87102 Zhejiang Province 315311 Country: USA Country: China Klaus Nicolaedis Jia Liu Contact: Tom Young Contact: Robin Luo 505-462-2190 +86-15267030962 Phone: 505-843-1418 Phone: +86-13621785753 FAX: NA FAX: NA klaus.nicolaedis@unirac.com jiu@cxymj.com Email: toddg@unirac,com Email: buwan.luo@cxymj.com Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office-, Lake Forest, CA U.S.A. Control Number: 5003705 Authorized by: for Dean Davidson, Certificate onager us 4 01TS - Teo Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark is for the exclusive use of Intertek a Client and a provided pursuant to the Certification agreement between hiterbsk and its Client, friterelk's responsibility and habdry are limited io the ',arms and conditions of the agreement, m.1prok assumes no liability to any early, other than to the Chent in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in Is entirety, Use of oteriek's Certification mark is restricted to the conditmns laid out in the agreement and in this Authorization to Mark. Any further use of the pitertek name for the sale or ai:hredisomen' afire, tested material, product or service most first be approved in writing by i-tertak, Initial Factory Assessments and Follow up Services are for the purpose of assunng appropriate usage of the Certification mark �accordance with the agreement, they are not for the Purposes of production quality control and do not relieve the Client at their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Standard(s): Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat - Plate Photovoltaic Modules and Panels [UL 2703: 2015 Ed.1] Product- Photovoltaic Mounting System, Sun Frame Microrail - Installed Using Unirac Installation Guide, Rev PUB2019MAR01 with Annex North Row Extension Installation Guide Rev PUB2019FEB20 Brand Name: Unirac Models: Unirac SFM ATM for Report 102393982LAX-002 Page 1 of 1 ATM Issued: 9-Apr-2019 FD 163 15 (20-Alp-17) Mandatory