HomeMy WebLinkAbout22-4420City of Zephyrhilis 7L,77,117"'7 5335 Eighth Street Zephyrhills, FL 33542 ELCMISC-004420-2022 Phone: (813) 780-0020 Issue Date: 07/14/2022 Fax: (813) 780-0021 REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies, �Mw"'Imrri IT17371' = 4XI., =W9, K%yI . accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. ........... .. . .... . . . . . . RACTOR SIGNATURE PE IT OFFICE PER IT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION '1! 1w 813-780-0020 City of Zephyrhills Permit Application Building Department Fax-813-780-0021 r, Date Received Phone Contact for Permitting - Owner's Name Barbara Malaba Owner Phone Number (401) 440-6211 11 Owner's Address k7856 Prairie Rose Lp ZephyrhiIts, FL 33542 Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 37656 Prair e Rase Lp Zephy hills, FL 33542 LOT # SUBDIVISION WALNUT GROVE TOWNHOUSES PARCEL to# 15-26-21-0210-00000-0070 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR BX ADD/ALT SIGN DEMOLISH El INSTALL REPAIR PROPOSED USE SFR COMM OTHER TYPE OF CONSTRUCTION BLOCK 0 FRAME STEEL DESCRIPTION OF WORK Installation of roof mounted photavol4aic solar system. BUILDING SIZE SO FOOTAGE HEIGHT €�Iiik-W t - C"IL x � L 'A�Ex "III tit k" ,k tlux V 't' �Ex x i.'W kX'% V-,�L"k�L't kx A W'E Ex BUILDING $ VALUATION OF TOTAL CONSTRUCTION $29,850 X ELECTRICAL $ 29,850 AMP SERVICE PROGRESS ENERGY = W.R.E C. PLUMBING $ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION GAS ROOFING = SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS �� FLOOD ZONE AREA =YES NO BUILDER COMPANY SIGNATURE REGISTERED Y / N FEE CURREN Address � License # �nT ._ _. ELECTRICIAN COMPANY Ensolar USA LLC SIGNATURE REGISTERED YIN FEE CURREN Y ( N Address License # PLUMBER COMPANY SIGNATURE REGISTERED �FE.RREN Y ( N Address License # MECHANICAL _ COMPANY SIGNATURE REGISTERED Y / N FEE CURREN Y / N_j Address License # OTHER COMPANY SIGNATURE _ _ REGISTERED Y / N FEE CURREN Y I N Address License # RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms, R-O-W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans: Stormwater Plans wl Silt Fence installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisionstlarge projects COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page, (1) set of Energy Forms, R-O-W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stornwater Plans wt Silt Fence installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required, (A/C upgrades over $7500) '* Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences (PloUSurveytFootage) Driveways -Not over Counter if on public roadways.. needs ROW 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County, TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a 'certificate of occupancy' or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances_ CONSTRUCTION MIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction lien Law —Homeowner's Protection Guide' prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner', I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner prior to commencement. CONTRACTOR'SIOWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. Southwest Florida Water Management District -Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers -Seawalls, Docks, Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency -Asbestos abatement. Federal Aviation Authority- Runways_ I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone "V" unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel: alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. OWNER OR AGENT Subscribed and sworn to (or affirmed) before me this by Who is/are personally known to me or has/have produced as identification. otary Public Commission Name of Notary typed, printed or stamped me identification. a^ Notary Public Commission No.w 1 Name o Nota typed, printed or stamped DIRECTOR'S OF PAGES PV-1 PROJECT SUMMARY PV-2 SITE PLAN PV-3 SINGLE -LINE DIAGRAM PV-4 SAFETY LABELS PV-5.1 ATTACHMENT PLAN 1 PV-5.2 ATTACHMENT PLAN 2 PV-6 ATTACHMENT DETAILS PV-7 FIRE SAFETY PLAN MODULE DATASHEET INVERTER DATASHEET ARRAY WIRING BOX DATASHEET X DISCONNECT DATASHEET w MOUNTING SYSTEM DATASHEET QMOUNTING SYSTEM ENGINEERING LETTER UL 2703 CLASS A FIRE CERTIFICATION UL 2703 GROUNDING AND BONDING CERTIFICATION ANCHOR DATASHEET PROJECT DETAILS PROPERTY OWNER BARBARA MALABA PROPERTY ADDRESS 37856 PRAIRIE ROSE LP, ZEPHYRHILLS, FL 33542 APN NIA ZONING RESIDENTIAL USE AND OCCUPANCY ONE- OR TWO-FAMILY DWELLING CLASSIFICATION GROUP (GROUP R3) AHJ CITY OF ZEPHYRHILLS UTILITY COMPANY DUKE ENERGY FLORIDA ELECTRICAL CODE 2017 NEC (NFPA 70) FIRE CODE 2020 FFPC OTHER BUILDING 2020 FL BUILDING CODE CODES I" I 32d I REYES M RL71Z DONATE PE# 88991 AN ENGINEER LICENSED PURSUANT TO CHAPMR 4M, CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL O DESIGNED APPROVEDAND USING THESNIA T' MOST RECENT VERSION O THE FLORIDA BUILDING CODE,' r Palmetto Palm 1 PARCEL PV-1 SCALE, NTS LOCALE P!{_' SCALE: ITS Prairie R fVap date @= SCOPE OF WORK THIS PROJECT INVOLVES THE INSTALLATION OF A GRID - INTERACTIVE PV SYSTEM, PV MODULES WILL BE MOUNTED USING A PREENGINEERED MOUNTING SYSTEM. THE MODULES WILL BE ELECTRICALLY CONNECTED WITH DC TO AC POWER INVERTERS AND INTERCONNECTED TO THE LOCAL UTILITY USING MEANS AND METHODS CONSISTENT WITH THE RULES ENFORCED BY THE LOCAL UTILITY AND PERMITTING JURISDICTION. THIS DOCUMENT HAS BEEN PREPARED TO DESCRIBE THE DESIGN OF A PROPOSED PV SYSTEM WITH ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITH APPLICABLE CODES AND REGULATIONS. THE DOCUMENT SHALL NOT BE RELIED UPON AS A SUBSTITUTE FOR FOLLOWING MANUFACTURER INSTALLATION INSTRUCTIONS. THE SYSTEM SHALL COMPLY WITH ALL MANUFACTURERS INSTALLATION INSTRUCTIONS, AS WELL AS ALL APPLICABLE CODES. NOTHING IN THIS DOCUMENT SHALL BE INTERPRETED IN A WAY THAT OVERRIDES THEM. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ALL DETAILS IN THIS DOCUMENT. SYSTEM DETAILS NEW GRID -INTERACTIVE DESCRIPTION PHOTOVOLTAIC SYSTEM WITH NO ENERGY STORAGE DC RATING OF SYSTEM 7.04KW AC OUTPUT RATINGS 4.64KW,19AA INVERTER(S) 16 X ENPHASE IQ8PLUS-72-2-US MODULE APTOS SOLAR DNA-144-MF26-44OW ARRAY WIRING (2) BRANCH OF 8 IQBPLUS-72-2-US MICROINVERTERS INTERCONNECTION DETAILS POINT OF NEW SUPPLY SIDE AC CONNECTION INTERCONNECTION PER NEC 705.12(A) UTILITY SERVICE 120/240V 1tp SITE DESIGN PARAMETERS ASHRAE EXTREME LOW -5°C (23°F) ASHRAE 2% HIGH 35°C (95°F) CLIMATE DATA SOURCE VANDENBERG AIRPORT WIND {ASCE 7 16j 137 MPH, EXPOSURE CATEGORY B, RISK CATEGORY 11 ) N. 88991 m STATE OF Digitally signed by Reyes Manuel Ruiz Donate Reason: Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Bate: 2022.07.11 17:22:13-04'00' 0 ra THIS ROOF CAN STAND THE LOAD OF THE WIND AND THE DEAD LOAD. 1 SITE PLAN f} PV-2 SCALE. V =10' GENERAL NOTES EQUIPMENT LIKELY TO BE WORKED UPON WHILE ENERGIZED SHALL BE INSTALLED IN LOCATIONS THAT SATISFY MINIMUM WORKING CLEARANCES PER NEC 110.26. 2417 UNESCORTED KEYLESS ACCESS SHALL BE PROVIDED TO ALL DUKE ENERGY FLORIDA EQUIPMENT. CONTRACTOR SHALL USE ONLY COMPONENTS LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY FOR THE INTENDED USE. CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL EQUIPMENT, CABLES, ADDITIONAL CONDUITS, RACEWAYS, AND OTHER ACCESSORIES NECESSARY FOR A COMPLETE AND OPERATIONAL PV SYSTEM. (E) MAIN SERVICE PANEL (MSP), OUTDOOR (E) UTILITY METER, OUTDOOR (N) AC COMBINER (Cl), OUTDOOR, OUTPUT CIRCUIT / CONDUCTORS SHALL BE RUN IN LFNC CONDUIT OVER ROOF NO CLOSER THAN 7/8" ABOVE ROOF SURFACE (N) VISIBLE -OPEN TYPE, LOCKABLE, READILY ACCESSIBLE, LABELED PV SYSTEM AC DISCONNECT LOCATED WITHIN 10 FT OF UTILITY METER (SW1), OUTDOOR (N) TRANSITION BOX (JB1), OUTDOOR, OUTPUT CIRCUIT CONDUCTORS SHALL BE RUN IN LFMC CONDUIT THROUGH THE INTERIOR OF THE BUILDING (N) PROPOSED ROOF -MOUNTED PHOTOVOLTAIC ARRAY. 4/12 (20.0-) SLOPED ROOF, 8 PV MODULES (BLACK FRAME, BLACK BACKSHEET), 270° AZIMUTH (N) TRANSITION BOX (JB2), OUTDOOR, OUTPUT CIRCUIT CONDUCTORS SHALL BE RUN IN LFMC CONDUIT THROUGH THE INTERIOR OF THE BUILDING (N) PROPOSED ROOF -MOUNTED PHOTOVOLTAIC ARRAY. 4/12 (20.0°) SLOPED ROOF, 8 PV MODULES (BLACK FRAME, BLACK BACKSHEET), 180° AZIMUTH ROADWAY ALL ARRAY CIRCUITS SHALL BE ROUTED THROUGH THE INTERIOR OF THE BUILDING, AND WHERE fl POSSIBLE, ALONG THE BOTTOM OF LOAD BEARING MEMBERS. NO CONDUIT SHALL BE INSTALLED ABOVE THE ROOF. �UEL�R(;tl�; No 88991 '7� a °m STATE OF ;per CREATOR: R.R. I r .� f PV MODULE 440W MICROINVERTER as 3 �l4 I qiq 81N 18IN a 8, CH dCN iiiI + i + y7 I I i i - JUNCTION BOX J81-2 l { 1 2 I 1 / AC COMBINER -- 2 C1 r---~ I l . /� /� U=�:� i 1 I 3 --- F1-2 PVACDISCONNECT L _ i 30A I EATON DG222NRB F I SW 4 SP W/150AMCB)LOADS T,'�16�01/L214TD 11 jj 1AILITY hI�ETER/240V 1�, 3W 1 PM1-16 1 16 1 APTOS SOLAR DNA-144-MF26-440W I 440VV 1 41OW 1 11.33A I 10T4A I 49.9V I 41.OV I-0.1452W-C (429%I°C) 1 20A I INVERTERS REF. QTY. MAKE AND MODEJ I AC VOLTAGE GROUND RATED POWER @qAX vUTPUi CURRENT MAX INPUT CURRENT I MAX INPUT VOLTAGE CEC WEIGHTED EFFICIENCY 11-16 1 16 21 NOT SOLIDLYGROUNDED 290VV t2A 15.0A 60V 97.0% DISCONNECTS OCPDS REF. QTY. MAKE AND MODEL RATED CURRENT MAK RATED VOLTAGE REF. QTY, RATED CURRENT MAX VOLTAGE SW1 1 EATON DG222NRB OR EQUIV. 60A VAC CB1-2 2 20A 240VAC F1-2 2 39A 240VAC RAPID SHUTDOWN DEVICES COPAPLIANT WITH REQUIREMENTS AS PER NEC 690.12(B)(2). PV CIRCUIT CONDUCTORS LOCATED OUTSIDE THE ARRAY BOUNDARY 4DEFINED AS 3 FEET FROM THE POiN7" OF ' '3 PENETRATION INTO A BUILDING OR MORE THAN 3 FEET FROM AN ARRAY) SHALL BE LltATEO TO NOT MORE THAN 30V W3THIN 30 SECONDS OF RAPID SHUTDOWN INITIATION. CONDUCTORS LOCATED INSIDE OF THE ARRAY BOUNDARY SHALL BE LIMITED TO NOT MORE THAN 80 VOLTS VVITHIN 30 SECONDS OF SHUTDOWN. ZL ENPHASE SYSTEM MEETS REQUIREMENT S FOR PHOTOVOLTAIC RAPID SHUTDOWN SYSTEM (PVRSS), AS PER NEC 690,12(B)(2). HE DC AND AC CONNECTORS OF THE ENPHASE 107PLUS-72-2-US AND ARE LISTED TO MEET REQUIREMENTS AS A DISCONNECT MEANS AS ALLOWED BY NEC 690.15(D). MATING CONNECTORS SHALL COMPLY WITH NEC 690.33. THE ENPHASE 107PLUS-72-2-US HAS A CLASS 11 DOUBLE -INSULATED RATING AND DOES NOT REQUIRE GROUNDING ELECTRODE CONDUCTORS (GEC) OR EQUIPMENT GROUNDING CONDUCTORS (EGO). THE RATING INCLUDES GROUND FAULT PROTECTION (GFP). TO SUPPORT GFP, USE ONLY PV MODULES EQUIPPED WITH DC CABLES LABELED PV INIRE OR PV CABLE. A MICRO€NVERTER BRANCH CIRCUIT CONDUCTORS ARE MANUFACTURED ENPHASE Q CABLES LISTED FOR USE IN 20A, OR LESS CIRCUITS OF ENPHASE IQ MICROINVERTERS. THEY ARE ROHS. OIL RESISTANT, AND UV RESISTANT, THEY CONTAIN T'V70 12 AVVG CONDUCTORS OF TYPE THHNriH%P!N-2 DRYNVET AND CERTIFIED TO UL3003 AND UL 9703. l "\ DC PV CONDUCTORS ARE NOT SOLIDLY -GROUNDED, NO DC PV CONDUCTOR SHALL BE WHITE- OR GRAY -COLORED ALL METAL ENCLOSURES, RACEWAYS, CABLES AND EXPOSED NONCURRENT -CARRYING METAL PARTS OF EQUIPMENT SHALL BE GROUNDED TO EARTH AS REQUIRED BY NEC 250.4(B) AND PART III OF ARTICLE 250 AND DC EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45. THE GROUNDING ELECTRODE SYSTEM SHALL ADHERE TO NEC 690.47(A) AND NEC 250.169 AND INSTALLED 1N COMPLIANCE WITH NEC 250.64. {� ti MAX DC VOLTAGE OF PV MODULE IS EXPECTED TO BE 54.2V AT -5°C (-4.9-C - 25°C) X -0.145V/C+49.9V = 54.2V}. ®, AC AGGREGATION PANEL BUSBAR AND THE OVERCURRENT PROTECTION PROTECTING THE BUSBA? SHALL BE SIZED IN ACCORDANCE WITH NEC 705.12(B)(2){3)(C). "1 THE ENPHASE IQ COMBINER 3 CONTAINS A FACTORY -INSTALLED COMMUNICATIONS GATEWAY WITH AN OCPD RATED NO MORE THAN 15A. POINT -OF -CONNECTION IS ON THE SUPPLY SIDE OF SERVICE DISCONNECT, AT A LOCALLY -APPROVED CONNECTION POINT, USING LOCALLY -APPROVED METHODS AND HARDWARE, IN COMPLIANCE WITH NEC 705.12(A). APV SYSTEM AC DISCONNECT SHALL BE A VISIBLE KNIFE -BLADE TYPE DISCONNECT THAT IS ACCESSIBLE AND LOCKABLE BY THE UTILITY. THE DISCONNECT SHALL BE LOCATED WITHIN 10 FT OF UTILITY METER. DISCONNECT SHALL BE GROUPED IN ACCORDANCE VVITH NEC 230.72. GROUNDED CONDUCTOR SHALL BONDED INSIDE DISCONNECT PER NEC 250.24(B) AND NEC 250.24(C). PV SYSTEM AC DISCONNECT MEETS NEC 690.12(C) REQUIREMENT FOR A RAPID SHUTDOWN iNITiAT]ON DEVICE CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS CURRENT -CARRYING MAX. TEMP.CORR. CONT. TERM. AMP.@ TERM. CONDUCTOR Dii CONDUIT /CABLE CONDUCTORS OCPD EGC FACTOR FILL FACTOR CURRENT CURRENT BASE AMP. DEBATED AMP. TEMP. RATING TEMP. RATING CONDUIT/CABLE. (125°fo) E. 1 10 AWG TH'VVN-2, COPPER IS' DIA. LFMu 2 20A 10 ANdG THAN-2, COPPER 0,76 (55-C) 1.0 9,6$A 12.1A 4flA 30.4A 90°C 40A 2 10 AWG THR(N-2, COPPER 1.0" DIA LFMC 2 20A 10 AWG THWN-2, COPPER 0T8 (55°C) 3.0 9.68A 12.1A 4CA 30.4A 90°C 40A 3 6AWGTHWN-2,COPPER 1.0"DIA. LFNC 3 30A 6AVVGTHWN-2,COPPER 0.96{35°C) 1.0 19.36A 24.2A 75A 72A 75°C 65A 4 6 A'WG Ti NN-2, COPPER I.0' DIA. LFNC I34A NtA 0.86 (35°C} 0 9.36A 24.2A 75A 72A 5°C 65A GENERAL ELECTRICAL NOTE UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC 1 SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE, CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS 2 SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE 310.10 (D), CONDUCTORS EXPOSED TO WET Uj LOCATIONS SHALL BE SUITABLE FOR 3 USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C). Of U n ej GROUNDING NOTES cy-a —� 3m ALL EQUIPMENT SHALL BE 1 PROPERLY GROUNDED PER THE REQUIREMENTS OF NEC ARTICLES 250 & 690 PV MODULES SHALL BE GROUNDED TO MOUNTING RAILS USING MODULE � LUGS OR RACKING INTEGRATED CO <c >_ GROUNDING CLAMPS AS ALLOWED 2 tt� BY LOCAL JURISDICTION, ALL OTHER EXPOSED METAL PARTS SHALL BE GROUNDED USING UL-LISTED LAY -IN LUGS. INSTALLER SHALL CONFIRM THAT CD MOUNTING SYSTEM HAS BEEN EVALUATED FOR COMPLIANCE WITH 3 UL 2703 "GROUNDING AND BONDING„ WHEN USED WITH PROPOSED PV " MODULE. `>� cEr IF THE EXISTING MAIN SERVICE N.88991 PANEL DOES NOT HAVE A = VERIFIABLE GROUNDING STATE OF xz 4 ELECTRODE, IT IS THE CONTRACTOR'S RESPONSIBILITY TO Digitally signed by Reyes Manuel Ruiz INSTALL A SUPPLEMENTAL Donate GROUNDING ELECTRODE, Reason: Printed copses of this AC SYSTEM GROUNDING document are not considered signed ELECTRODE CONDUCTOR (GEC) and sealed and the signature must be 5 SHALL BE A MINIMUM SIZE #BAWD verified on any electronic copies. Date: 2022.07.11 17:22:30-04'00' WHEN INSULATED, #6AWG IF BARE WIRE, EQUIPMENT GROUNDING SINGLE -LINE DIAGRAM CONDUCTORS SHALL BE SIZED ACCORDING TO NEC ARTICLE 690.45, 6 AND BE A MINIMUM OF #10AWG PROJECT ID: 2D81C0-1 WHEN NOT EXPOSED TO DAMAGE, DATE: 07/11/22 AND #6AWG SHALL BE USED WHEN CREATED BY: R.R. EXPOSED TO DAMAGE GROUNDING AND BONDING CHECKED BY: CONDUCTORS, IF INSULATED, SHALL REVISIONS 7 BE COLOR CODED GREEN, OR MARKED GREEN IF #4AWG OR LARGER SINGLE -LINE DIAGRAM F�V-3 SCALE: NTS PV-3 (D AC COMBINER PANEL (Cl) NEC705.12(B)(2)(3)(C) (D AC SOLAR DISCONNECT (SW1 IN NULL) EACH DISCONNECTING MEANS FOR PHOTOVOLTAIC EQUIPMENT (SW1) NEC690,13(B) (D AC DISCONNECT (SW1 IN NULL) LABELING NOTES - - ------- - P-D906FE ALL AND SIGNAGE PLAQUES AND SIGNAGE REQUIRED BY 2017 NEC PC WILL FTJAND 2020 FFPC WILL BE INSTALLED AS REQUIRED, LABELS, WARNING(S) AND MARKING SHALL COMPLY WITH ANSI Z535.4, WHICH REQUIRES THAT DANGER, WARNING, AND CAUTION SIGNS USED THE STANDARD HEADER COLORS, HEADER TEXT, AND SAFETY ALERT SYMBOL ON EACH LABEL. THE ANSI STANDARD REQUIRES A HEADING THAT IS AT LEAST 50% TALLER THAN THE BODY TEXT, IN ACCORDANCE WITH NEC 110.21(B). A PERMANENT PLAQUE OR DIRECTORY SHALL BE INSTALLED PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LLJ c/) LOCATION IN ACCORDANCE WITH NEC 690,56(8), C) Lli -------- cr- z: co LABEL(S) WITH MARKING, "TURN RAPID SHUTDOWN SWITCH TO THE'OFF' POSITION TO SHUT DOWN THE uj 0 ENTIRE PV SYSTEM,` SHALL BE LOCATED WITHIN 3 FT OFu- SERVICE DISCONNECTING MEANS THE TITLE SHALL UTILIZE CAPITALIZED LETTERS WITH A MINIMUM HEIGHT UJI OF 318" IN BLACK ON A YELLOW BACKGROUND, AND REMAINING TEXT SHALL BE CAPITALIZED WITH A Of lif MINIMUM HEIGHT OF 3/16" IN BLACK ON WHITE < < BACKGROUND fir, r1w Of LABEL(S) WITH MARKING, 'RAPID SHUTDOWN SWITCH 0 < — >- FOR SOLAR PV SYSTEM," SHALL BE LOCATED WITHIN 3 FT OF RAPID SHUTDOWN SWITCH THE LABEL SHALL 0 L0 a- HAVEHAVE 3/8" TALL LETTERS AND BE REFLECTIVE WITH Lli t, WHITE TEXT ON A RED BACKGROUND �kkjEL Rij > -'\CENS ffi0 No 88991 STATE OF 0 "',SIONAL C STRUCTURAL DESIGN PARAMETERS SEISMIC 0.061 SDS WIND (ASCE 7-16) 137 MPH, EXPOSURE CATEGORY B, RISK CATEGORY 11 GROUND SNOW LOAD 0 PSF ROOF PROPERTIES ROOF MATERIAL COMPOSITION SHINGLE (1 LAYER) SLOPE 4/12 (20.0°) MEAN ROOF HEIGHT 15.6FT ROOF DECKING 15/32" OSB CONSTRUCTION TRUSSES (2X4 TOP -CHORD), 241N OC MODULE MECHANICAL PROPERTIES MODEL APTOS SOLAR DNA-144-MF26-44OW DIMENSIONS (AREA) 82.51N X40.91N X 1AIN (23A SO FT) WEIGHT 55.3LB MOUNTING SYSTEM PROPERTIES RAIL MODEL IRONRIDGE XR100 ANCHOR MODEL ROOF TECH RT2-04-SD5-60, 2.881N AIR GAP 2,0 INCH EMBEDMENT INTO TRUSSES FASTENING METHOD OR DECKING WITH (2) 3/16IN DIA. FASTENERS GROUNDING AND INTEGRAL GROUNDING CERTIFIED BONDING TO UL 2703 REQUIREMENTS NOTES TRUSS LOCATIONS ARE APPROXIMATE, ANCHORS MAY BE FASTENED TO DECKING WHERE NEEDED, IN NO CASE SHALL THE ANCHOR SPACING EXCEED 'MAX. ANCHOR SPACING" ANCHOR PLACEMENT PARAMETERS (ASCE 7-16) }WIND PRESSURE ' MODULE WIND MAX, ALLOWABLE MAX. ANCHOR MAX. ALLOWABLE ZONE EXPOSURE RAIL SPAN SPACING CANTILEVER ZONES 1, 2E, 2R, NORMAL 72.01N 72.01N 28.81N 3 DISTANCE a IS EQUAL TO 10% OF THE BUILDING'S LEAST HORIZONTAL DIMENSION ("LHD") OR 40% OF THE MEAN ROOF HEIGHT, WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF THE LHD OR 3 FT. THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE ROOF PLANES IN ACCORDANCE WITH GUIDANCE PROVIDED BY ASCE 7-16 FIGURES 30.3-2B-1. a = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 ` LHD), 0.04 * LHD, 3 FT) 3.2 ft = max(min(0.4 * 15.6 ft, 0.1 * 31.7 ft), 0.04 * 31.7 ft, 3 ft) ♦4�4;1458B99gps No 88991 > °° STATE OF "�tt o' ,; f > i ®®p.,rS/O A � ATTACHMENT AN DATE: 7/11 /22 1 STRUCTURAL DESIGN PARAMETERS SEISMIC 0.061 SDS WIND (ASCE 7-16) 137 MPH, EXPOSURE CATEGORY B, RISK CATEGORY 11 GROUND SNOW LOAD 0 PSF ROOF PROPERTIES ROOF MATERIAL COMPOSITION SHINGLE (1 LAYER) SLOPE 4/12 (20.0°) MEAN ROOF HEIGHT 15.6FT ROOF DECKING 15/32" OSB CONSTRUCTION TRUSSES (2X4 TOP -CHORD), 241N OC MODULE MECHANICAL PROPERTIES MODEL APTOS SOLAR DNA-144-MF26-44OW DIMENSIONS (AREA) 82.51N X 40.91N X 1.41N (23.4 SO FT) WEIGHT 55.3LB MOUNTING SYSTEM PROPERTIES RAIL MODEL IRONRIDGE XR100 ANCHOR MODEL ROOF TECH RT2-04-SD5-60, 2.881N AIR GAP 2.0 INCH EMBEDMENT INTO TRUSSES FASTENING METHOD OR DECKING WITH (2) 3/161N DIA. FASTENERS GROUNDING AND INTEGRAL GROUNDING CERTIFIED BONDING TO UL 2703 REQUIREMENTS NOTES TRUSS LOCATIONS ARE APPROXIMATE. ANCHORS MAY BE FASTENED TO DECKING WHERE NEEDED, IN NO CASE SHALL THE ANCHOR SPACING EXCEED "MAX. ANCHOR SPACING" gm ANCHOR PLACEMENT PARAMETERS (ASCE 7-16) DISTANCE a IS EQUAL TO 10% OF THE BUILDING'S LEAST HORIZONTAL DIMENSION ("LHD") OR WIND PRESSURE MODULE WIND MAX. ALLOWABLE MAX. ANCHOR MAX. ALLOWABLE 40% OF THE MEAN ROOF HEIGHT, WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF THE LHD ZONE EXPOSURE RAIL SPAN SPACING CANTILEVER OR 3 FT. THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE ZONES 1, 2E, 2R, NORMAL 72.01N 72,01N 28.81N ROOF PLANES IN ACCORDANCE WITH GUIDANCE PROVIDED BY ASCE 7-16 FIGURES 30.3-2B-1. 3 a = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 * LHD), 0.04 * LHD, 3 FT) 3.2 ft = max(min(0.4 * 15.6 ft, 0.1 * 31.7 ft), 0.04 * 31.7 It, 3 ft) LIM � Xa 140EL Rt/J`3 es°® tics �e®--�C. E ft s--*,,0� No 88991 `.� �m s� s STATE OF ®mom ®p$57 - 11,1111110 ATTACHMENT PLAN DOC ID: 2D81C0-1 DATE: 7/11122 CREATOR: R.R. REVIEWER: REVISIC}NS RACKING ELEVATION JRANSVERS CIEW \)�'V SCALE: NTS 4 IRONRIDGE UNIVERSAL—, /4IRONRIDGE UNVERSAL PV MODULE FASTENING OBJECT W1 FASTENING OBJECT STOPPER SLEEVE COMP. SHINGLE ROOFING IRONRIDGE I XRl GO RAIL Ll Lil ROOF DECKING ROOF FRAMING SPACING ATTACHMENT SPAN ROOF FRAMING RACKING ELEVATION (LONGITUDINAL EJEW SCALE: NTS MOUNTING SYSTEM NOTES ELA3HlNj2 SHALL BE APPLIED IN ACCORDANCE WITH MANUFACTURERS'INSTRUCTIONS. IF THERE IS ANY CONFLICT BETWEEN WHAT IS DEPICTED HERE AND INSTRUCTIONS 2 PROVIDED BY A MANUFACTURER, THE MANUFACTURER'S INSTRUCTIONS SHALL SUPERCEDE. IRONRIDGE UNIVERSAL FASTENING OBJECT ROOF TECH RT-MINI (INSTALL AS PER MANUFACTURER'S INSTALLATION MANUAL) COMP. SHINGLE ROOFING STAINLESS WOOD SCREWS EMBEDDED INTO ROOF FRAMING IRONRIDGE XR1 00 RAIL IRONRIDGE L-FOOT APPLY ROOF SEALANT TO THE TOP & EACH SIDE OF THE BRACKET J­ROOF DECKING \1 /`­ onnr UNDERLAYMENT ROOF FRAMING ATTACHMENT DETAILLTMNSVERSE VIEW) 1\p_v-) SCALE: NTS ROOF TECH RT-MINI - --! (INSTALL AS PER MANUFACTURERS INSTALLATION MANUAL) COMP. SHINGLE ROOFING ROOF UNDERLAYMENT ROOF DECKING ROOF FRAMING, ---IRONRIDGE XR100 RAIL 7" MAX. TO TOP OF RAIL L--i- APPLY ROOF SEALANT TO THE TOP & SIDES OF THE BRACKET STAINLESS WOOD SCREWS EMBEDDED INTO ROOF FRAMING K'D-'\, ATTACHMENT DETAIL (LONGITUDINAL VIEW) SCALE: NTS �AUEL RU No 88991 STATE OF 0 .......... 'IS10NAL %NN "111111110k ATTACHMENT DETAILS =1 ACCESS AND SPACING REQUIREMENTS SHALL BE REQUIRED TO PROVIDE EMERGENCY ACCESS TO THE ROOF, PROVIDE PATHWAYS TO SPECIFIC AREAS OF THE ROOF, PROVIDE FOR SMOKE VENTILATION OPPORTUNITY AREAS, AND TO PROVIDE EMERGENCY EGRESSION FROM THE ROOF. THE AHJ SHALL BE PERMITTED TO MODIFY ROOF ACCESS BASED UPON FIRE DEPARTMENT VENTILATION PROCEDURES OR ALTERNATIVE METHODS THAT ENSURE ADEQUATE ACCESS, PATHWAYS, AND SMOKE VENTILATION. (FFPG 11.122.21) NOT LESS THAN TWO T WIDE PATHWAYS ON SEPARATE ROOF PLANES, FROM GUTTER TO RIDGE, SHALL BE PROVIDED ON ALL BUILDINGS. ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR DRIVEWAY SIDE OF THE ROOF. FOR EACH ROOF PLAN WITH A PV ARRAY, A 3' WIDE PATHWAY FROM GUTTER TO RIDGE SHALL BE PROVIDED ON THE SAME ROOF PLANE AS THE PV ARRAY, ON AN ADJACENT ROOF PLANE, OR STRADDLING THE SAME AND ADJACENT ROOF PLANES. PATHWAYS SHALL BE LOCATED IN AREAS WITH MINIMAL OBSTRUCTIONS SUCH AS VENT PIPES, CONDUIT, OR MECHANICAL EQUIPMENT. (FFPC 11A2.2.2.2.1) FOR PV ARRAYS OCCUPYING UP TO 33% OF THE PLAN VIEW ROOF AREA, A MIN, 18" PATHWAY SHALL BE PROVIDED ON EITHER SIDE OF A HORIZONTAL RIDGE. (FFPC 11.12222.2) PV MODULES INSTALLED ON ROOF WITH IRONRIDGE ROOF MOUNTING SYSTEM. THE MOUNTING SYSTEM IS UL 2703 CLASS A FIRE RATED ON THIS STEEP -SLOPED ROOF WHEN INSTALLED WITH TYPE 1 OR 2 MODULES. THE APTOS SOLAR DNA-144-MF26-440W IS UL 61730-1 CERTIFIED TYPE 1. (; 1.5 WIDE FIRE ACCESS PATHWAY, PER FFPC 11.122.2,2.1 1.5' WIDE FIRE ACCESS PATHWAY 4 ROOF ACCESS POINT ROADWAY TOTAL PLAN VIEW ARRAY AREA IS 352.3 SQ.FT, WHICH REPRESENTS 16.6% OF TOTAL PLAN VIEW ROOF AREA (2123.7 SQ.FT) THIS SYSTEM UTILIZES MICROINVERTERS, THERE ARE NO DC CIRCUITS OUTSIDE OF THE ARRAY PERIMETER OR INSIDE THE BUILDING, ALL ARRAY CIRCUITS SHALL BE ROUTED THROUGH THE INTERIOR OF THE BUILDING, AND WHERE POSSIBLE, ALONG THE BOTTOM OF LOAD BEARING MEMBERS. NO CONDUIT SHALL BE INSTALLED ABOVE THE ROOF. FIRE SAFETY PLACE PlA-7 SOLE.: V =10' •,c at��a \CEtVgdmC� q No 88991 �g o� STATEOF 0se ��t?Rgt�9a FIRE SAFETY Residential I Commercial 30 Year 1 5 3X IEC RETC Top Warranty St !lords Performer 3140 De to Cruz Blvd., Ste 200 Santa Clara, CA 95054 tOS" Irv---aptossolar,com S_, r technology info@aptossolar,com Designed & Engineered in Silicon Valley 440W I 445W 1450W Our DNA" Split Cell Series impressively combines advanced solar technologies to maximize performance. Our patented Dual Nano Absorber (DNAT`1) Technology allows the panel to operate at high -efficencies in extreme temperatures. Contact our sales team today to learn more about our line of high-efficienty solar panels. Patented DNATm technology boosts power performance Sc module efficiency Advanced split cell technology with 9 ultra -thin busbars allows for less resistance and more photon LL--J capture (�) Ideal solution for applications affected by shading All -black design for pristine aesthetics No excessive silver bussing or ribbons Robust product design is reslient in extreme weather. Up to 5400 Pa snow load and 6200 Pa wind load O(T� as c E UM Intertek C CH us *,aR 6W xWj u� UL61730-1, UL61730-2 Linear Performance Warranty 9851. 97% 9(r7% 83,7% 8o2% 76,7% 0 Aptos Warranty * Industry Standard 35m, STCrated Output P_ (W) 440W 445W 450W Module Efficiency 20.2191 20,43% 20.66Y. Open Circuit Voltage V_ (V) 49,9 50A 50.3 Short Circlut Current Isc (A) 11.33 11,40 11A7 Rated Voltage V_ (V) 41-0 412 41A Rated Current l _ (A) 10.74 10,81 10,88 Temperature Coefficients Pn_ -0-38% Temperature Coefficierits 1. +005%/Ic Temperature Coefficients V, -0.29%/C Normal Operating Cell Temperature (NOCT) 441C Maximum Series Fuse 20A Maxinturn System Voltage 1,000 VDC (UL&JEC) Maximum Load Capacity (Tested to UL 1703) 5400 Pa Snow Load/ 6200 Fla Wind Load Fire Performance Class Class C/Type I Number of Modules per Pallet 31 Number of Pallets per 40ft Container 22 Pallet Dimensions 2110 X 1120 X 2365 Pallet Weight (kg) 810A Container Weight (kg) 17823 Antos Solar Technology reserves the right to make specification changes without notice 12 a I R, >4 00 rn:: => do to ::r- 0 Z- cal A -A, 72-7 B.3 Cell Type Monocrystalline Class 3,2mm, and -reflection coating, high tra-nclsSion, low 1ron, tempered glass Frame Anodized Aluminum Alloy Junction Box IP68 Dimensions 2095 X 1039 X 35mm, output Cable 4mm2 (EU)12AWG Weight 53.131bs.(25Akg) Cable Length (47.24)1200mm Encapsulant POE (S) us Oa-usC E Intertek U161730-1, cw UL61730-2 Is , n. ENPHASE. Our newest 108 Microinverters are the industry's first microgrid-forming, software - defined microinverters with split -phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor -based microinverter is our proprietary application -specific integrated circuit (ASIC) which enables the microinverter to operate in grid -tied or off -grid modes. This chip is built in advanced 55nm technology with high speed digital logic and has super -fast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. Part of the Enphase Energy Systern, fQ8 sense Microinverters integrate With the Enphase 10 Battery,:Enphase 10 Gateway, and the Enphase App monitoring and analysis software. 111,; ,9R ; *-,A - 117 Connect PV modules quickly and sasjjjjiy to 108 Was Mlorpinvarters using the included 4-DCC-2 adapter cable with plug-n-play MC4 connectors, with various regulations, when 1 ailed according to manufacturees instn ndlons; 0 2022 Enphase Energy. Ali rights reserved. Emma", the Enphase logo, 108 necroinvernue, and other names are trademarks of Enphase Energy, I= Data subject to charge, IOBSE-DS-0001-01-EN-US-2022-03-01 Lightweight and compact with plug-n-play connectors Power Line Communication (PLC) between components Faster installation With simple two -wire cabling High productiVity and reliability Produce power even when the grid is down More than one million cumulative hours of testing Class It double -insulated enclosure Optimized for the latest high- powered PV modules Microgirld-forming - Comolles With the latest k7=0i range of lgrW proo* - Maki CA Rule 21 (UL 1741- r me . 0— -0 > 0 __4 ::10 rn 0- 00 M:rn on 00 10 sCe IN Commonly used module paldngs2 IN 235-350 235-440 260-460 295-500 320-540- 295-500- Module compatibility 60-celf/120 half-pell 60-celf/120 half -cell, 66-ceIV132 half -cell and 72-celf/144 half -cell MPPT voltage range V 27-37 29-45 33-45 36-45 38-45 38-45 operating range v 25-48 25-58 min/max start voltage V 30/48 30/58 Max input DC voltage V 50 60 Max Do current' [module Ise] A 15 Overvoltage, class DO port If DC port backfeed current mA 0 PV array configuration 1xI Ungrounded array, No additional DCside protection required; AC side protection requires max 20A per branch circuit Peak output power. VA 246 300 330 366 384 366 Max continuous output power VA 240 290 325 349 380 360 Nominal (L-L) voltage/ran 240/211-264 208/1183-250 Max continuous output current A lo t21 t35 1.45 1-58 V3 Nominal frequency. Hz 60 Extended frequency —go in, 50-68 Max units per 20 A ((-L) branch circuit/ 16 13 11 11 10 9 Total harmonic distortion .5% Overvoluige class AC port lit AC port backfeed current rk 30 Power factor setting 1.0 Grid -tied power factor (Adjustable) 0-85 leading - 0.85 tagging Pearkefficiency 915 97.6 97.6 976 97.6 97A CEC weighted efficiency % 97 97 97 97:5 97 97 Night-time power consumption MW 60 Ambient cenpicature range -40°C to +60*C (-40*F to -14OPF) MEN= Relative humidity range 4% to 100% (condensing) DC Connector type MC4 Dimensions (HxWxD) 212 mm (8,Y) x US mm (6.9") x 30.2 mm (1,21 weight 1.08 kg (2Z8 lbs) Cooling Natural comection - no fare Approved for wet locations Yea Acoustic noise at I m <60 dBA Pofftrtlon degree PD3 Enclosure Clear 11 double -insulated, corrosion resistant polymeric enclosure Erf4rom category / UV exposure rating NEMA Type 6 / out CA Rule 21 (UL 1741-W, UL 62109-1, U6.1741/ISEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-=2 Na IG7.1-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 69012 and C22A-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and Do conductors, when installed according to manufacturer's instructions. (1) The IOSH-208 variant will be operating in grid -tied mode only at 208V AC. (2) No efforced DC/AC ratio. See the compatibility calculator at httpw//Iinkenphase=m/module-compafffbirity (75) Maximum continuous input Do current is 10,6A (4) Nominal voltage range can be extended beyond nominal If required by the utility. (5) Units may vary. Refer to focal requirements to define the number of mcroinverters per branch in your area I48SE-DS-0001-01-EN-US-2022-03--01 Eriphase Networking r-11 Enphase IQ Combiner 3 (X-M-AM1-240-3) LISTED To learn more about Enphase offerings, visit enphasexom The Erlphase IQ Combiner 3_' mth Enphase 1Q EnvoY"' consolidates interconnection equipment into a single enclosure and streamlines PV and storage installations by providing a consistent, pre -wired Solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. Smart Includes IQ Envoy for comrnunication and control Flexible networking supports Wi-Fi, Ethernet, or cellular Optional AC receptacle available for PLC bridge Provides production metering and optional consumption monitoring Reduced size from previous combiner Centered mounting brackets support single stud mounting Supports back and side conduit entry Up to four 2-pole branch circuits for 240 VAC plug-in breakers (not included) 80 A total PV or storage branch circuits umm - Durable NRTL-certifiedNEMA type 3R enclosure Five-year,warranty UL listed o" ENPHASE, ',tilt I Ill,," 0 ZZ:0 w>® Mdo 0000 1-0 0 Q0 Irv, s, % Enphase IQ Combiner 3 MODEL NUMBER ACCESSORIES and REPLACEMENT PARTS (not included, order separately) Consumption Monitoring* CT CT-200-SPLIT Split core current transformers enable whole home consumption metering (+/- 2-51/.). EPLC-01 Power line carrier (communication bridge pair), quantity 2 XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3 (required for EPLC-01) XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board (PCB) for Combiner 3 ELECTRICAL SPECIFICATIONS System Voltage 120/240 VAC, 60 Hz Eaton BP, series busbar rating 125 A Max, continuous current rating (output to grid) 65A Branch circuits (solar and/or storage) Up to 'our 2-pole Eaton Be series Distributed Generation (DG) breakers onp, (Plot included) max. continuous current rating (input from Pal) 64A Max. total branch circuit breaker rating (input) 80A of distributed generation / 90A with IQ Envoy breaker included ME1113212MEEM Weight T 5 kg (16,5 ibs) Ambient temperature range -401 C to +461 C (401 to 1151 F) Cooling Natural convection, plus heal, shield Enclosure environmental rating Outdoor, NIRTL-certified, NEMA type 3R, polycarborrate construction Wire sizes 20 Ato 50 A breaker inputs: 14 to 4 Woo copper conductors 60 A breaker branch input: 4 to 1/0 ApIG copper conductors Main lug combined output: 10 to 210AVIG copper conductors Neutral and ground: 14 to 1/0 copper conductors Always follow level code requirements for conductor sizing. Attitude To 2000 meters (6,56,3 rest) INTERNET CONNECTION OPTIONS Ethernet Optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included) Compliance, IQ Envoy UL 60601-1,/CANCSA 22.2 No. 61010-1 * Consumption monitoring is required for Eriphase Storage Systems. To learn more about Enphase offerings, visit enphase.com '9, 20 1 v Ennhas,_ Ene,jy Al ngh!.�, use AH I radefnatks ),I bl-81nds n ,is doc.ument are �y lhv,ii :,,',-;rv,,,e 0'eIrw-r nENPHASE 3 aIRON RIDGE Muilt for solar's toughest roofs. Flush Mount System 1ronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 25-year warranty. Strength Tested All components evaluated for superior structural performance. Class A Fire Rating Certified to maintain the fire resistance rating of the existing roof. UL, 2703 Listed System Entire system and components meet newest effective UL 2703 standard. Pre -stamped engineering letters available in most states. 25-Year Warranty Products guaranteed to be free of impairing defects. XR Rails MW A low -profile mounting rail for regions with light snow. 6' spanning capability Moderate load capability Clear and black finish Clamps & Grounding ✓ i ter, The ultimate residential solar mounting rail. 8' spanning capability Heavy load capability Clear and black finish A heavyweight mounting rail for commercial projects. 12' spanning capability Extreme load capability Clear anodized finish a�k$�t4aa�aet�rr mZ •g�, aC C40 A ® m � m; r Oko b _ �Fplf &I46ii141 All rails use internal splices for seamless connections. Self -drilling screws Varying versions for rails Forms secure bonding jpa OF ,. ,, Universal Fastening Objects bond modules to rails. Fully assembled & lubed Single, universal size Clear and black finish Flash and mount XR Rails with superior waterproofing. Twist -on Cap eases install Wind -driven rain tested Mill and black finish R sourc;es Snap onto the UFO to turn into a bonded end clamp. Bonds modules to rails Sized to match modules Clear and black finish ��r✓ �� �i/�i lr f✓ ��r✓�%�fX�,;,r �i � fi y��//rr ✓ f✓rFr � � ,r ✓ r f✓/r✓r rr,. Flash and mount conduit, strut, or junction boxes. Twist -on Cap eases install Wind -driven rain tested Secures 3/4' or 1 ' conduit Bond modules to rails while staying completely hidden. Universal end -cam clamp Tool -less installation Fully assembled Drop -in design for rapid rail attachment. Secure rail connections Slot for vertical adjusting Clear and black finish Connect arrays to equipment ground. Low profile Single tool installation Mounts in any direction Bonding Hardware Bond and attach XR Rails to roof attachments. T & Square Bolt options Nut uses 7/16" socket Assembled and lubricated Design Assistant NABCEP Certified Training o from rough layout to fully Earn free continuing education credits, r ¢ C r; engineered system For free while learning more about our systems Go to Go bu 7 ..-%�'" ��""�, ��c- ,��=� ..�', .. ,.,-.-=„�.-..:.M. .. ✓. .?; � ,�-�`.'"-= �^ .,..ram �F% .,�..-'" . .r: .,r~-. ,. ,- .---. "Ps�"�. F. ., tY :r., ,�> ;. ,xw-"K;wu-.,-- ., �: � r - .� �.,-a-,�, w. ,..;.�r^,�-�'�*.�-�-: r"�� �� Y,�%� :mow."-=^. .��%r'` .,m., ,,.=��ir �`- ✓~,. ,.�,..,�`r>: ,..,�.,; ,.� -`�i .Y,-�'c�.�.z;�� _ � � _ _ a`r� s t ^ ���� x-� ���� �F � �.. ,. � �.. � ,f �.y_ r< ,✓ .c�" sue',. �r-�.' >.�:-= :� �� .,_:��'" -.�� /�" �� »-�.�.. �.-, -� r „�,- <w=. r�'.�.- ,sue _.= :r'-.�� ✓',.�. ..�r,- RT-MINI is suitable for mounting any rail system with a conventional L-Foot. Dual bolt design: M8 or 5/16 13 for L-Foot & 1/4" for EMC 1CC ICC ESR 3575 Now for more details 858-935-6064 Engineered to ASTM D 1761 (Standard Test Methods for Mechanical Fasteners in Wood) Components RT2-00-MINIBK PAT: PENDING MINI base :20 ea. Screw: 40 ea. Extra RT-Butyl : 10 ea. RT-Butyl is Roof Tech's flexible flashing used in 550,000 residential PV systems for the last 20 years. It is the first PV mounting system with Flexible Flashing certified by the ICC. Metal Flashing Retrofit Shedding water? 100% Waterproof ) testing UV testing (7500 hrs.) Dimensions in (mm) o 3 1/2 (90)-- 2 (50) Rafter installation Deck installation r 1,E es 3 ! " P.E. Stamped Letters available at www.roof-tech.us/support