Loading...
HomeMy WebLinkAbout22-4600Name: PEDRO MIGt I Address: 5202 18Th St EPHYRHILLS, FL 33542 Phone: (813) 297-2996 MM e _ •; . w . issue ServicePermit Type: Electric � Class of Work: Add/Alter Residential Xw 101 rM10112 I i'll Let fillm Building Valuation: $1.00 Electrical Valuation: $63,318.00 Mechanical Valuation: Plumbing Valuation: Total Valuation: $63,319.00 Total Fees: $36.59 Amount Paid: $356.59 Date `Paid: 8/15/2022 3:26:30PM L REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553,80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first remspection, whichever is greater, for each subsequent reinspection. Notice♦ • the requirements♦ • property .r agenciesmay be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state +agencies. JQ�� 1A Ir 813-780-0020 City cat /-epnyrrinlS r-tG[ ruts Building Department Date Received Phone Contact for Permitting 813 687 __ 8040 Owner's Name Pedro Fernandez Owner Phone Number 813.297,2996 Owner's Address 5202 18tia St Zeph chills, FL 33542 Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 5202 1 atilt �eiJi1 chills, Fi 33542 LOT# SUBDIVISION City Of ZephyrhlliS PARCELID# 11-26-21-0010-1�a00-0140 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD/ALT SIGN DEMOLISH e INSTALL REPAIR PROPOSED USE SFR COMM L�J OTHER TYPE OF CONSTRUCTION BLOCK 0 FRAME STEEL DESCRIPTION OF WORK Install i.6S5kW calif mounted SOlcar S 5t8rYi ® BUILDING SIZE. SQ FOOTAGE HEIGHT =BUILDING $ I VALUATION OF TOTAL CONSTRUCTION ✓ ELECTRICAL $�} AMP SERVICE PROGRESS ENERGY W.R,E.C. 63,318 PLUMBING $= =MECHANICAL. $ VALUATION OF MECHANICAL INSTALLATION =GAS ROOFING SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDERE:== COMPANY SIGNATURE REGISTERED YIN ®r �G.R.NY /N Address License # E===:= ELECTRICIAN COMPANY Modern Cahce tS Solar and Roofin SIGNATURE ._" *"' REGISTERED YIN FEE GUPREN Y / N Address 01 N Franklin St #2200 Tafnpa, FL 33602 License# EC13011433 PLUMBER _...._._. ..®� COMPANY SIGNATURE REGISTERED � Y / N FEE CURREN Address License # MECHANICAL COMPANY SIGNATURE REGISTERED YIN FEE CURREN Y ( N Address License #� OTHER COMPANY SIGNATURE REGISTERED YIN FeF C.RRIN Y 1 N Address License # E�� RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans wl Silt Fence installed, Sanitary Facilities & 1 dumpster, Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (A/C upgrades over $7500) Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage) Driveways -Not over Counter if on public roadways..needs ROW Bui,dingoepartmem NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations, The undersigned assumes responsibility for compliance with any applicable dead restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the. owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 80M Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting, It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to pen nit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law —Homeowners Protection Guide." prepared by the Florida Department of Agriculture and Consumer Affairs, If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner"poor to commencement, CONTRACTOR'SIOWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development, Application is hereby made to obtain a permit to do work and installation as indicated, 1 certify that no work or installation has commenced prior to issuance of a pennit and that all work Wil be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction, I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I Must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally SensitivE Lands, VVatarMuatewamrTreatment. - Southwest Florida Water Management Distriot-meb, Cypress 8ayhoada, Wetland Areas, Ak*hog Watercourses, Army Corps ofGngin*ors-Seawa||n.Docks, Navigable Waterways. - onpomnmnt of Health & Rehabilitative SorWoea/Envimnmo^ta| Health Unb4wo|ls. vvastewate, Treatment, Septic Tanks. ' VSEnvironmental Protection Agency -Asbestos abatement. - Federal Aviation Authority- Runways, / understand that the following restrictions apply tothe use mfill: - Use nffill iunot allowed inFlood Zone 'V' unless expressly permitted. If the fill mou*rie| in to be used in Flood Zone ''A^, it in understood that a drainage plan addressing a ^compensating volume" will be submitted aktime ofpermitting which is prepared by professional engineer licensed »ythe State orFlorida. ' |fthe fill material is to be used in Flood Zone ^A" in connection with u permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall, ' If fill material is to he used in any area. | certify that use of such fill will not adversely affect adjacent properties, If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1 acre which are elevated by fill, is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing mmamctim/ understandthat m o, other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension, If work ceases for ninety (90) consecutive days, the job is considered OWNER OR AGENT CONTRACTOR_ Subscribed and sworn to (or affirmed) before me this bacritLeft.�nd sworn Who is/are personally known to me or has/have produced Wh i / 11 -W t 0 as identification. K�-| r x �as mvmmuati", _ ~ Commission No_HH_&M4y15__ Commission Name of Notary typed, printed or stamped 76 AJorth Meadowbrook Drive Alpine, UT 84004 office (201) 874-3483 swyssling@tArysslingcor)stilting,com • Suite 2200 T 1 ampa, FL 33602 Re: Engineering Services Fernandez Residence 5202 181h Street, Zephyrhills, FL 7.695 kW System To Whom It May Concern: 1. Site visit documentation identifying attic information including size and spacing of framing for the existing roof structure, Z Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels, This information will be utilized for approval and construction of the proposed system. 3 Roof Framing: Assumed prefabricated wood trusses at 24" on center. All truss members are constructed of 2x4 dimensional lumber, Roof Material: Composite Asphalt Shingles Roof Slope: 23 degrees Attic Access: Inaccessible Foundation: Permanent Dead Load * Existing Roofing and framing = 7 psf * New Solar Panels and Racking = 3 psf * TOTAL = 10 PSF • Live Load = 20 lost (reducible) — 0 psf at locations of solar panels ® Ground Snow Load = 0 psf ® Wind Load based on ASCE 7-16 * Ultimate Wind Speed = 140 mph (based on Risk Category 11) * Exposure Category B Analysis performed of the existing roof structure utilizing the above loading criteria is in accordance with the FBC 2020 (7th Edition) including provisions allowing existing structures to not require strengthening if the new loads do not exceed existing design loads by 1051 for gravity elements and 110% for seismic elements. This analysis indicates that the existing framing will support the additional panel loading without damage, if installed correctly. to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to r,ontact me, Florida License # RY34912 Date Signed08/0Q/2O22 W,VSSUNG CONSTULTING ° 19 X JINKO SOLAR: JKM405M-72HL-V 405W MONO MODULES ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES DC SYSTEM SIZE: 19 x 405 = 7.695KW DC AC SYSTEM SIZE: 19 x 290 = 5.51OKW AC EQUIPMENT SUMMARY 19 JINKO SOLAR:JKM405M-72HL-V 405W MONO MODULES 19 ENPHASE IQ6PLUS-72-2-US 290W MICROINVERTERS EQUIPPED WITH RAPID SHUTDOWN ROOF ARRAY AREA #1:- 411.54 SO FT. NOTE: VISIBLE, LOCKABLE, LABELED AC DISCONNECT LOCATED WITHIN 10' OF UTILITY METER a rl z M SITE PLAN PV-2 SCALE: 1/16" = 1'-0" (N) ENPHASE COMBINER BOX ROOF #1 (19) JINKO SOLAR: JKM405M-72HL-V 405W MONO MODULES WITH ENPHASE • i (E) MAIN SERVICE PANEL (OUTSIDE) - (E) UTILITY METER g 1 , PROPERTY LINE (E) GATE (TYP.) L - (E) FENCE I— (E) TREES DESIGN SPECIFICATION OCCUPANCY: FI CONSTRUCTION: SINGLE-FAMILY ZONING: RESIDENTIAL GROUND SNOW LOAD: REFER STRUCTURAL LETTER WIND EXPOSURE: REFER STRUCTURAL LETTER WIND SPEED: REFER STRUCTURAL LETTER S A MODERN CONCEPTS SOLAR 201 N. FRANKLIN ST. SUITE 2200 TAMPA, FL 33602 REVISIONS DESCRIPTION 1 DATE 'REV INITIAL DESIGN 08/04,2022 8 0 lilt," t STATE ORI a ��rtltr€s3t��ti��= Wyssling Consulting, PLLC 76 N MeadawbrookDrive Alpine UT 84004 Florida License # RY34912 Date Signed 08/09/2022 PROJECT NAME & ADDRESS Uj I— LL T —J3 00 CL Lj I N DRAWN BY ES SHEET NAME SITE PLAN SHEET SIZE ANSI 11" X 17° SHEET NUMBER ITV- MODULE TYPE, DIMENSIONS & WEIGHT NUMBER OF MODULES = 19 MODULES MODULE TYPE = JINKO SOLAR: JKM405M-72HL-V 405W MONO MODULES MODULE WEIGHT = 49.0 LBO / ZZ.DNizl. MODULE DIMENSIONS = 79.06" x 39.45" = 21,66 SF (N) EVEREST K2 SYSTEMS CROSSRAIL 44-X (36) EVEREST K2 SYSTEMS SPLICE FOOT XL ATTACHMENT ROOF #1 (19) JINKO SOLAR:JKM405M-72HL-V 405W MONO MODULES WITH ENPHASE IQ8PLUS-72-2-US 290W MICROINVERTERS ROOF #1 PITCH - 23' AZIM. - 270 ROOF PLAN & MODULES PV-3 SCALE: 3/16" = l'-O" ROOF DESCRIPTION ROOF TYPE ASPHALT SHINGLE 1 LAYER ROOF AZIMUTH TRUSS TRUSS S PITCH SIZE SPACING 23' 270' 2"X4" 24" ARRAY AREA & ROOF AREA CALC'S TOTAL PV ARRAY TOTAL ROOF ROOF AREA AREA AREA COVERED BY (SQ. FT,) (Sq. Ft.) ARRAY 411,54 1565-05 26 33 9 4 5 C) JINKO SOLAR: JKM405M-72HL-V 405W MODULES 'END - JUNCTION BOX -SOLADECK - INVERTER - COMBINER BOX - AC DISCONNECT - UTILITY METER - MAIN SERVICE PANEL - VENT, ATTIC FAN (ROOF OBSTRUCTION) - ROOF ATTACHMENT - ------ -RAFTER - CONDUIT S,,LAR MODERN CONCEPTS SOLAR 201 N. FRANKLIN ST. SUITE 2200 TAMPA, FL 33602 REVISIONS DESORPTION DATE I REV 1NITIAL DESIGN 08/04/2022 1 Date Signed 08/09/2022 PROJECT NAME & ADDRESS N w U) co z LLJ uj co uJ < 0 z z LL Lu w LL co 0 uj cy C14 >_ C) 04 Lo w w 0— N PAWN B ESR SHEET NAME ROOF PLAN & MODULES SHEET SIZE ANSI B 11 " X 17" SHEET NUMBER PSI- DO SYSTEM SIZE, 19 x 405 = 7.695KW DO AC SYSTEM SIZE. 19 x 290 = 5.510KVJAC (19) JINKO SOLAR: JKM405M-72HL-V 405W MONO MODULES WITH (19) ENPHASE IQ8PLUS-72-2-US 290VV MICROINVERTERS cuuIrr7-u WITH m mArlu SHUTDOWN L)ljvvN LOCATED UNDER EACH PANEL (240V) CIRCUIT LEGENDS CIRCUIT#1 CIRCUIT #2 (19) ENPHASE IQ8PLUS-72-2-US 29OW MICROINVERTERS EQUIPPED WITH RAPID SHUTDOWN LOCATED UNDER EACH PANEL (240V) 1 ELECTRICAL PLAN somommmommsm PV-4 SCALE: 3/16" = 9'-0" -- BILL OF MATERIALS EQUIPMENT QTY 1 DESCRIPTION SOLAR PV MODULES 19 1 JINKO SOLAR: JKM405M-72HL-V 405W MODULE S LAR 7 7-- MODERN CONCEPTS SOLAR 201 N. FRANKLIN ST. SUITE 2200 TAMPA, FL 33602 REVISIONS DESCRIPTION DATE REV INITIAL DESIGN r8)0-12022 I Date Signed 08/09/2022 PROJECT NAME & ADDRESS N C14 ui It 0 1-2 Lo m z ui uj uj z Z u- or- LEI ui C) T 00 LL cn 00 0 ui T- 0 04 U-) uj Lli CL N DRAWN BY _____� ESR SHEET NAME ELECTRICAL PLAN SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-4 Ili Will! SCALE: EVEREST K2 SYSTEMS CROSSRAiL 44-X 3) EVEREST K2 SYSTEMS PUCE FOOT XL ATTACHMENTS -) ASPHALT SHINGLE ROOF MODERN CONCEPTS SOLAR 201 N. FRANKLIN ST. SUITE 2200 TAMPA, FL 33602 REVISIONS DESCRIPTION DATE REV INITIAL DESIGN M04t2022 i0 EfIf1/dP "�df STAIrE 0~` 4oqxD°ro& Wyssling Consulting, PLLC Yb N Meadowbrock Drive Alpine UT 84004 Florida License # RY3412 Date Signed 08/09/2022 PROJECT NAME & ADDRESS C\1 LO EL L,s DRAWN BY ESIR SHEET NAME STRUCTURAL [DETAIL SHEET SIZE ANSI B 11" X 17" SHEET NUMBER - DC SYSTEM SIZE: 19 x 405 = 7,695KW DC AC SYSTEM SIZE: 19 x 290 = 5.510KW AC I (19) 31NK0 SOLAR: JKM405M-72HL-V 405W MONO MODULES WITH (19) ENPHASE IQ8PLUS-72-2-US 290W MICROINVERTERS EQUIPPED WITH RAPID SHUTDOWN LOCATED UNDER EACH PANEL (240V) (1) BRANCH CIRCUIT OF 9 MODULES AND (1) BRANCH CIRCUIT OF 10 MODULES CONNECTED IN PARALLEL JINKO SOLAR:JKM405M-72HL-V 405W MODULES BRANCH #1 1 I 2 3 o 0 0 8 9 s s i o 0 o s I BRANCH #2 � 1 2 3 0 0 0 9 10' L, INTERCONNECTION MOTES: 1. INTERCONNECTION SIZING, LIMITATIONS AND COMPLIANCE DETERMINED IN ACCORDANCE WITH [NEC 705.12], AND (NEC 690.591 2. GROUND FAULT PROTECTION IN ACCORDANCE WITH [NEC 215.91, (NEC 230,951. 3. ALL EQUIPMENT TO BE RATED FOR BACKFEEDING. 4. PV BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE BUSBAR RELATIVE TO THE MAIN BREAKER. DISCONNECT NOTES: 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THE TERMINALS MARKED "LINE SIDE" (TYPICALLY THE UPPER TERMINALS) 2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE -BREAK SWITCH 3. DISCONNECT MEANS AND THEIR LOCATION SHALL BE IN ACCORDANCE WITH (NEC 225.311 AND [NEC 225,321. ENPHASE IQ COMBINER X-iQ-AM1-240-4/4C 120/240VAC, 1+ , 3W 125A RATED BUS BAR, NEMA 3R SOLAR LOADS ONLY UL 1741 COMPLIANT IQ ENVOY : PER MANUFACTURER SPECIFICATIONS, EITHER IQ ENVOY 10A OR 15A BREAKER IS SUITABLE FOR USE 15A/2P SOLADECK, 20AI2P 600V, NEMA 3R, o d UL LISTED � 20A/2P BRANCH TERMINATOR - _- (ET -TERM) ENPHASE IQ8PLUS-72-2-US 29OW MICROINVERTERS EQUIPPED WITH RAPID SHUTDOWN r" ' LOCATED UNDER EACH PANEL (240V) 1 ELECTRICAL LINE DIAGRAM PV-6 SCALE: NTS GROUNDING & GENERAL NOTES: 1. PV GROUNDING ELECTRODE SYSTEM NEEDS TO BE INSTALLED IN ACCORDANCE WITH [NEC 690.431 2. PV INVERTER IS UNGROUNDED, TRANSFORMER -LESS TYPE. 3, DC GEC AND AC EGC TO REMAIN UNSPLICED, OR SPLICED TO EXISTING ELECTRODE 4, ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT IS FOUND TO BE INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINAL INSPECTION. 5. SOLADECK QUANTITIES, AND PLACEMENT SUBJECT TO CHANGE IN THE FIELD - SOLADECK DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE TYPE TRANSITIONS. 6. AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER AC DISCONNECTING MEANS IS LOCATED WITHIN 10' OF SERVICE DISCONNECT. 7. RACEWAYS AND CABLES EXPOSED TO SUNLIGHT ON ROOFTOPS SHOULD BE INSTALLED MORE THAN 7/8" ABOVE THE ROOF USING CONDUIT SUPPORTS. RACKING NOTE: 1. BOND EVERY RAIL WITH #6 BARE COPPER PV AC DISCONNECT L1 240V, 1�, 3W L2 30A RATED N NEMA 3R G LINE _ _r LOAD 2 N --- VISIBLE, LOCKABLE, LABELED AC DISCONNECT LOCATED WITHIN 10' OF UTILITY METER 30A/2P aq N G GEC EXISTING GROUNDING ELECTRODE SYSTEM TO EARTH REF. NEC 250.52, 250.53(A) TO UTILITY GRID m ;—L2 —N BI-DIRECTIONAL UTILITY METER 120/240V, 1�, 3-W (E) MAIN BREAKER TO HOUSE 240V, 150A/2P (E) MAIN SERVICE PANEL, GE 150A RATED, 240V LOAD/LINE SIDE INTERCONNECTION AT MAIN PANEUSUB-PANEL PER ART. 705.12 BACK -FEED BREAKER REF 2017 NEC 705.12(B)(2)(3)(b) QTY CONDUCTOR INFORMATION CONDUIT TYPE CONDUIT SIZE (4) #12AWG _ ENPHASE ENGAGE CABLE f (L1 & L2 NO NEUTRAL) N/A NIA (1) #10AWG - CU,THWN-2 GND r (4) #10AWG- CU,THWN-2 (1 } #10AWG - CU,THWN-2 ONO EMT OR LFMC IN ATTIC 314" (2) #10AWG- CU,THWN-2 r (1) #10AWG - CU,THWN-2 N EMT, LFMC OR PVC 3/4" {9} #10AWG - CU,THWN-2 GND (2) #10AWG CU,THWN-2 (1) #10AWG- CU,THWN-2 N EMT, LFMC OR PVC 3f4" (1) #10AWG- CU,THWN-2 GND MODERN CONCEPTS SOLAR 201 N. FRANKLIN ST. SUITE 2200 TAMPA, FL 33602 REVISIONS ( DESCRIPTION `DATE REV INITIAL DESIGN 08104/2022 STATE 012 pry, �� ,V; N ` iiPI3i94§?ttt yg Consulting, PLLC 76 N MeadubrookDrive Alpine UT 34004 Florida License # RY34912 Date Signed 08/09/2022 PROJECT NAME & ADDRESS pp�q� 0� co co w _j F- a LL w Uj N DRAWN BY =—SR SHEET NAME ELECTRICAL LINE DIAGRAM SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-6 INVERTER SPECIFICATIONS SOLAR MODULE SPECIFICATIONS AMBIENT TEMPERATURE SPECS RECORD LOW TEMP -1' MANUFACTURER / MODEL # MANUFACTURER ENPI- ASE IQ MICROINVERTERS S 29OSHUTDOWN MANUFACTURER / MODEL # JINKO SOLAR:JKM405M-72HL-V 405W MODULE i AMBIENT TEMP (NIGH TEMP 2%) I 33' WITH RAPID SHUTDOWN RAPID S MODULE TEMPERATURE COEFFICIENT OF Voc -0.281/d°C MINIMAX DC VOLT RATING 22V MIN/ 60V MAX VMP 42.OV PERCENT OF NUMBER OF CURRENT MAX INPUT POWER 235W-440W IMP 9.65A VALUES CARRYING CONDUCTORS IN EMT NOMINAL AC VOLTAGE RATING 240V/ 211-264V VOC 50AV .80 4-6 MAX AC CURRENT 1.21A ISO 10.48A 70 7-9 MAX MODULES PER CIRCUIT 13 (SINGLE PHASE) TEMP, COEFF. VOC -0.28%/°C 50 10-20 MAX OUTPUT POWER 290 VA MODULE DIMENSION 79.06"L x 39.45"W x 1.57"D (In Inch) j AC,CALCULATIONS �. DERATION FACTOR DERATION FACTOR 90'C CIRCUrr FULL LOAD VOLTAGE FLA*1,25 OCPD CONDUCTOR 35'C AMPACITY AMBIENT ii3TALCC 901C ( FOR AMBIEN T FOR C{iNDUCTORS AMPACITY AMPACITY FEEDER CONDUCTOR VOLTAGE CONDUIT CONDUIT ! CIRCUIT ORIGIN DESTINATION AMPS "FLA" (V) (A) SIZE (A) NEUTRAL SIZE GROUND SIZE SIZE � AMPACITY � CHECK #1 TEMP. (°C) CONDUCTORS AMPACITY (A) TEMPERATURE NECTER RACEMIAY NEC DERATED CHECK #2 l33£i,15{B)(2)(a) LENGTH RESISTANCE DRf3P AT SIZE FILL (%) I (A) (A) IN RACEWAY i 313,1E{8}(3)(a) (p) (FEET) (OHM/KFT) FLA (4} CIRCUIT 7 SOLADECK 240 10,89 13.61.2E 20 N/A CU #610 AWG CU #12 AWG 25 DA65 33 2 30 0,96 i 1 28.8 PASS 0,38 Fi/A CIRCUIT 2 SOLADECK 240 12.1 15.125 l 20 N/A CU #1€7 AWG CU #12 AWG 25 PASS 33 2 30 v i 0,96 1 28.8 PASS 0.4E N/A SOLADECK COMBINER PANEL 2 240 121 15.125 20 N/A CU #10 AWG Cu #10 AWG 35 PASS 1 33 4 40 0,96 0,8 30,72 PASS 25 1.24 1 0-313 3/4" EMT COMBINER PANEL 1 AC DISCONNECT 240 22:99 1 28.737E 1 30 CU #10 AW6 CU #Zi? AWG CU #10 A G 35 { 455 33 2 40 0,96 3 38A SAS 5 ?.2= 0,119 j 3/4„ EMT ! AC DISCONNECT pot 240 22.99 1 28.733E 1 30 CU #f10 A1Ji CU #10 AWG CC #10 Ai IG 1 35 PASS 33 2 4 0.96 I 1 38.4 ? 57 5 1.24 1 03 119 3/4" EMT Circuit 1 Voltage Drop 0.930 Circuit 2 Voltage Drop 1 1,010 I . ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED 1 WIRING, CONDUIT, AND RACEWAYS 2. ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. AS POSSIBLE TO THE NEAREST RIDGE, r , OR VALLEY. . WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 5. DRAWINGS INDICATE THE GENERAL ARRANGEMENTCONTRACTOR SUPPORTS, WHERE6. RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, 7. ALL AP PROPRIATELY r VISIBLE. CLIPS& MODULE GROUNDING O BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE 9. MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA GROUNDING CLIP MANUFACTURER'S INSTRUCTION. LUG OR ILSCO GBL-4DBT LAY -IN LUG. 10. TEMPERATURE PAT INGS OF ALL CONDUCTORS, TERMINATIONS, BREAKERS, OR OTHER DEVICES ASSOCIATED WITH THE SOLAR PV SYSTEM SHALL BE RATED FOR AT LEAST 75 DEGREE C. MODERN CONCEPTS SOLAR 201 N. FRANKLIN ST. SUITE 2200 TAMPA, FL 33602 REVISIONS DESCRIPTION DATE REV INITIAL DESIGN 08/04/2022 } 58 STATE D Wyssling Consulting, PLLC Meadowbrook Drive Alpine 07 84004 lodda License # RY34912 Date Signed 08/09/2022 PROJECT NAME & ADDRESS w co L L! co 0 l— CINI LIJ 0— N DRAWN BYESR SHEET NAME WIRING CALCULATIONS SHEET SIZE ANSI 11" X 17" SHEET NUMBER V®7 S LAR LABEL-t LABEL LOCATION: AC DISCONNECT OMM ME 1- mg, ON ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL- 2: LABEL LOCATION AD DISCONNECT COMBINER MAIN SERVICE PANEL SUBPANEL MAIN SERVICE DISCONNECT CODE REF: NEC 690,13(B) TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL LABEL- 4 LABEL LOCATION: MAIN SERVICE PANEL SUBPANEL MAIN SERVICE DISCONNECT COMBINER CODE REF: NEC 11 0.27(C) & OSHA 1910.145 (0 (7) LABEL- 5: LABEL LOCATION: MAIN SERVICE PANEL (ONLY IF SOLAR IS BACK -FED) SUBPANEL (ONLY IF SOLAR IS BACK -FED) CODE REF: NEC 705.12(B)(3-4) & NEC 690,59 LABEL- 6- LABEL LOCATION: MAIN SERVICE PANEL (ONLY IF SOLAR IS BACK -FED) SUBPANEL (ONLY IF SOLAR IS BACK -FED) CODE REF: NEC 705.12(B)(3)(2) TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS LABEL- 7 LABEL LOCATION: AC DISCONNECT CODE REF: FFPC 11,12.1.1.1.1 &NEC 690,56(C) LABEL- 8: LABEL LOCATION: AD DISCONNECT CODE REF: NEC 690,56(C)(2) 0 LABEL- 10: LABEL LOCATION: MAIN SERVICE PANEL SUBPANEL AC DISCONNECT CODE REF: NEC 690.54 MODERN CONCEPTS SOLAR 201 N. FRANKLIN ST, SUITE 2200 TAMPA, FL 33602 REVISIONS DATE I REV DESCRIPTION I INITIAL DESIGN 1 W04/2022 1 1 1558 Z STATE NAX, Imm0l, Wyssling Consulting, PLLC 76 N Meadowbrook Drive Alpine UT 84004 Florida License # RY34912 PROJECT NAME & ADDRESS N C14 Uj ` Q U) co z w w co w < 0 W cr- Lu 0(6 IL C) T I.- LL — 0 CO 0 Uj T- 0 C14 U-) LLJ Uj a_ N DRAWN BY ESR SHEET NAME LABELS SHEET SIZE ANSI B 11 " X 17" SHEET NUMBER PV-8 € O ER TO THIS BUILDING IS ALSO SUPPLIED FROM MULTIPLE SOURCES OF POWER WITH SAFETY DISCONNECTS AS SHOWN: E COMBINER BOX 'CONNECT V SERVICE PANEL DE) ILITY METER mmopmalm 5202 13TH STREET, ZEPH'YRHILLS, FL, 33542 (ALL PLAQUES AND SIGNAAE WILL BE INSTALLED AS OUTLINED WITHIN - EC 690.56(R)&(C), [NEC 705.101) PER FFPC 11.12.2.1.4 LABELING NOTES 1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. 2. LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRIC CODE, OSHA STANDARD 19010,145, ANSI Z535. 3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [NEC 110.211 5. LABELS TO BE A MINIMUM LETTER HEIGHT OF 318", WHITE ON RED BACKGROUND; REFLECTIVE, AND PERMANENTLY AFFIXED FFPC 11.12.2.1.1.2 ___ _ -_. 1 1 MODERN CONCEPTS SOLAR 201 N. FRANKLIN ST. SUITE 2200 TAMPA, FL 33602 REVISIONS DESCRIPTION DATE REV INITIAL DESIGN OW0412022 ��§�qbE dt###pPtfgF 5 STATE Wysst 4w � ig Consulting, PLLC Yb N Meadowbrook Drive Alpine UT 84004 Florida license # RY34912 PROJECT NAME & ADDRESS LL LLl < 0 0 co T £� CO Cq CL DRA'JVN BY E SIR SHEET NAME PLACARD SHEET SIZE ANSIB 11" X 17" SHEET NUMBER V_ 71 v' 1EI�-07Y,� �-rEE6 pn, WWI 1 OW 72HL --V ------- - -- ...... ........ .... .. - - --------------- - - ------- - - --- c@us CE LISTED '11 K0 KEY FEATURES Diamond Ceff Technology High Voltage 1 aanc' v"4 �r HigheylModule Power Shade ToWfance 'N',c'e, � "ad'e --ienwce d, e zc an, PID FPEE ----- - --- -- I I r7777 Strength and Dwabifity LINEAR P"Ek-WORMANCE 141-1. IRRAN' 70 Yew producl 'Afarfwdy - 25 yeaUneaf w-'eter %plar-an"y W wwo I'm rR11900 N" "?HL V I XN'tt—rt NiftAmun Auxwar *,RaT,Mp; 41IV >f 7y' U 4L r 1 M- AV 42,2,V, 40 TV 7 P 96,11, Z �21'11 9 - Q= 5�v 48, 2111V 4'N,9,1 4&W 50'tV Ar"?v 5GAiV 4&W Xb A !`,A I LA S 14coik, FOk"iv ry -�!C &311%,Fsn .,6,h % R) set,-- R'�' Z STC NO CTA M - 5 -Nzi-icJ ' A— S,,,LAR --- MODERN CONCEPTS SOLAR 201 N. FRANKLIN ST. SUITE 2200 TAMPA, FL 33602 REVISIONS DESCRPTION DATE REV INITIAL DESIGN 08104/2022 PROJECT NAME & ADDRESS N N w Ilzr Q LO c z w ui co ui < Z z LL 0� w w 0 F- u- — co CO 0 Lu C14 c:) c) U-) w ui DRAWN BY ESR SHEET NAME EQUIPMENT SPECIFICATION SHEET SIZE ANSI B 11 " X 17" SHEET NUMBER Pv-1 1 LA R x NHE Our revues`K28 groin /orl r are the ndtotty'sftrst,microgri form€r ,: sftware- didineamicusinv rters with split -Phase power conversion Capability tcconvert DO =. aver to A r power e entiy. The brain of the se.?nip;onduc tor-ba sead microinverter c our proprietary applicat on-sptc=ftc Jrftxeg.axed circuit CtSiC `,sch# enables the micro -In erter to operate iogrid-tied of Off-gh modes, T ,4 s nobi:p is Iu.:T in advaYiced s, m tscx nolcgy rai th Ngh speed dtip tal logic and new s per-fdmt resp r st times charging loads arJgrid events, a,lematin Constraints on battlery sizingf'.x home -energy Systems, MOO- r"oft eE-ophase.EIeggySystem K0 Seas 4 ESeriesWc_ yeti t--, rflne;,;E.aUkry ra.:rd4z8 err Pandardsrthmaca,thano e <„i&vt":.e;wTuiatY-. En"'phizie, K1, GeFoay,a,w„ the E',-rhas. S„,z...., i a,,,N v=recnswmbiog, a. dsur: d- a.�. V.-in , warrarth& 7,25 A-s,s, ^e i £4:. t '�., i". L' 3Pt tF C F ..., .„e' Sr. { r`sa` 5�'�S" F 4 - u+,'xF4, 0C2 a>-.,r 0 -,,fa,treer s t er =trorra, 2d22 Erphase Emtizf .l gh. s r--erved,'--nphose, he EnPhaSeogo, _a sr d ct1' er oiS_ ',0303-C,fix. Uw-2G2z 03-17 Easy to install Lic hvssa ht a,s-I Compact Faith, plug-ti play connectors Porter Line Communication (PLC) beteeen components Faster ,inztallation e ,th ample trio -wire- sibling High productivityand r iabllity Produce purer evens wher, the id is doeirf' More than one million n currnulats`ve hours of testing Class ii doubte-€noulatcd er`C.iz`;s4_re Optimized'or t is est ha Microgrid-forming mi Complies trith. the .atest advanced grid support — Remote autorn abc updates for the latest grid requirements insQ. g(radlS to support a YtSFS-fib-' range of gnd Profiles Meets CA Rule 21 (UL 1741-SA) requirements ents ors, „ 'UL 1741, 5u,fauons ,.i^ and C5 cemr,cv'N cset cdr; t .r is, W 23 350 a'.a- 0 uti n? 'kz s'+.J' .i€ sS.Ct and I 144 Medu... .,.- 3.,L:cL4 PO-c, .,w...0 .. .ie3,r o,» artge 27 -a. w -4a aperar,ilnvrange 25- 48 .-n315 50 60 MaxC aur,eralfmadubt # _io '' _, Dcpert , Do . b kfsra. c,,,vAnt •,h O {aE a'4: ., +dts,t:,{,.,;., ,Y,>uu.,gXGu'Y%''uF`a: ?s,.✓?E.iC E'Ia.,EDC as{.`,..CJ.,,,..t.±,....,.:gL.t......,'r,.: ^sU`?p,".. ,....,...;,:, lecL9fs^2fi 'Y 3 Na'..0 Gf^Y ,..,,..�..:< Max n;tn xrtjo outDot currefq -, t/j rraroi /er,uen y Ha. Sr; WCehi,$t,. u_ LaAtcurrpjaz �,qer vu Ar!z 23 o � v ,e 0 A ._ L, a a, -- _;,,zr,>°rt' 0,c< dofta e srIa"SAC i wer-car..ueS currore. -A vu Gfia- . 70 pcwaccf s+, tat, re) 03.5 ea r;c 85 agq' Pea t. efhci smi ... 9T5 W's N,,r, ,rrr,e par.,, oars •niptica:n effif 60 Aaib;ent tempeesurevartge -40 G%,,.6C•"G, 4CP€ 1,ox1401= Do rs r r type P„,jr`4 E2ma, A'3 fxi,t.,. , o-92 x 30. 2.,, t 1.08k.E. 42,78n, Roofs,,,. vs. ..,fans x,for water ry t UN . xpo""�tre einq ?'x.EMA y` ,;--6 / a.»#`, oo,, & Rue, 210tea ' ; S.A), UL 62109-1,,Uv, JR3. EEE1547 FCC Psirtl,5 tOass 8, ICES-0-003 Coss, B, : ANICSs C2o2 NO.IUM-01 Ties R, .= _ UL Lioe.: a; RV Napo Shot Doane Equipment asyd conforms,,vith NEC220g 2 IEC 20177, <„al NEC 2020s: ---i*n 6E0.12aP;x: C-72.r?tb"SRus,60 -21a Rapid etyatdawmofPVSwmam,fee X0, and Do ,onz'io...,.,, wisam fnPfl6daacxxding to r c _.S's... a "4,,.R.�.,-, r .u.,; C--cu .n, ,--Eii ,.. crli:�,>, hsge A.a. ..�c, ,.N�,., .n_dnV~:r*i.., r,, ,.... G.- .0 vP' o,Vs lury va-r. Refer toocalrf;..r..ure en -Ts -7 .,.>,n. the numbery,;,o„r Drarch a vw, are, Q5PDS-,ja22-x .,a2022-t3-Ti _ __ : _ ,. v? OWN - MODERN CONCEPTS SOLAR 201 N. FRANKLIN ST, SUITE 2200 TAMPA, FL 33602 REVISIONS DESCRIPTION DATE REV INTIAL DESIGN 0810,412022 PROJECT NAME & ADDRESS co co Uj gig net 0. DRAWN BY E.SR SHEET NAME EQUIPMENT SPECIFICATION SHEET SIZE ANSI B 11" X 17` SHEET NUMBER Phi-12 I S LAR U-1 I Enphase A 17 4 A X-IQ-AMI-240-4 X-IQ-AMl-240-4C 0 , .1 _1r a'r- Pb EPHSE Enphase lQ Combiner 4,1AIC", MODEL WJ XISER 7� J, z' "c' a- 2 "o J�flem' nea� V AD 0 ESS 0 R I E 3 AND A E P L ACE N1 ENT PARI, S CiUMIDDEM, M� 0'6 Sle os' T"dcff" �Vt"S' '-Ow S'Nm dat" -�)3an' U "R 3 2 e v K 2 x 4c x A - i r20 3 X4, -NAWHID-125A 4aMicc-wr kg ELECTRIC AL SPECIFICATIONS mg "g- re-C, cvts �so;a� ar / "'lax ',val _. 4--ur'er"-> 1'n'G� . .... . mptoon A - A, �i�Aol vurmv"� r�an-'�-urrn MECHANICAL DATA I, m"enskwos ... ....... 3,7 -5 49 x �6 2, x '9 5" x s 'W f53,5 .,,r�w�-'-' ;*�'ug"�Vna ng NR 'ed, NEIMA' pc'oyr;avb'��"eik-" -4 4 A?iG cl INTERNET CONNECTION OPTIONS --- -------- bu 2, 3 b COMPLIANCE ia "2 ENPHASE MODERN CONCEPTS SOLAR 201 N. FRANKLIN ST. SUITE 2200 TAMPA, FL 33602 REVISIONS DESCRIPTION DATE REV INITIAL DESIGN 03104/2022 PROJECT NAME & ADDRESS N w z ui uj co ui < () of z z �— u- cr- Lu u) u� �— —j u- 00 Dui c\j C) T- Q C14 Lo CL LLI LLJ 0- N DRAWN B ESR SHEET NAME EQUIPMENT SPECIFICATION SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-1 3 LAR 40f-,G06C,, 4000061, 400-00-57 4 0 0 00,38 410,01"D-14,33, 40U�04311 jSSIRail LILI-X Mechanical Properties 34,8 ks� i,",240 MPa' I ... 4 0 2 87 Dimensions in Imml inches MODERN CONCEPTS SOLAR 201 N. FRANKLIN ST. SUITE 2200 TAMPA. FL 33602 REVISIONS DESCRIPTION DATE REV WTIAL DESIGN 0810412022 PROJECT NAME & ADDRESS N w 0 LO m z ui uj co w z Z L.L O� Lij Lli C) -J LL co m o LLJ C14 >- 0 04 LO LLJ CL IN 44 X E-d C o DRAWN BY Sb-1 7ctural vali-jes and span chart, de�errrdned in accordance ,m: 1 Akffi- nurr! Des-Ign Nrlan ual and ASI-2 7- 16 1 OR AM6,08amp stiver tar D-arlk 4006601 -H,, �,WY),4,0244 7 4o- ESR UL21 03 List-d Sys-em and 8-ondlitng SHEET NAME �3 CS, E, d Ciamp, Si!-,,e,,- o, Dar,,,< 40Cf0e,42940,00430 EQUIPMENT SPECIFICATION 14 1 E, d alil, , ddo: 40, Ou SHEET SIZE ANSI B 11" X 17" SHEET NUMBER Pit-14 We support PV systems Formerly Everest Solalr Systems 0� Splice Foot XL P&&n Pending N We support PV systems Formerly Everest Solar S',,TSteMSO% Units: [in] mm IS, LAR =17- 0-11-l'-N MODERN CONCEPTS SOLAR 201 N. FRANKLIN ST. SUITE 2200 TAMPA, FL 33602 REVISIONS DESCRIPTION DATE REV INITIAL DESIGN 08/04/2022 PROJECT NAME & ADDRESS N 04 w 't LO co z w Li! Ct3 Uj z z LL C6 LIJ c) U- U) 00 0 Uj T- CK w C14 >- 0 04 LLI Uj CL N DRAWN BY ESR SHEET NAME EQUIPMENT SPECIFICATION SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-1 5 A' R . . . . . . . . . . . . . . I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Basic Features 0 Stamped Seamless Construction # 18 Gauge Galvanized Steel * Powder Coated Surfaces 0 Flashes into the roof deck 0 3 Roof deck knockouts 5', 75% 1 0 5 Centering dimples for entry/exit fittings or conduit * 2 Position Ground lug installed * Mounbrig Hardware Included "Fuse ho' ders and terminal added in the field must be UL listed at recogr,oed and rneet 500 VIDG, 30 ANIP 110Gfor wse holder,, 600V 50-AMP 90C for rail mounted ieumnal bioilo; and 600 V 175 AMP 90C for Pcmver Distfibibor, ftcks, Use Copper V'4re ctinduvom S c alaDeck klode[ SD 0783 AvailableNlodefs: Model SD 0783 - (3'fixed Din Rail) Model SD 0786 - (6' slotted in Rail) SolaDeck UL 1741 Combiner/Enclosures Madek; SD 0783-41 and SD 0786-411 ai e labeled and ETL listed UL S TJD 1741 according to 'he UL STD 1-7-41 for Phohnioltaic cornbiner ericjosvres, Max Rated - 60OVDC, 120AMPS Model SID 0783-41 3" Fixed Din Rail fastened using Norlock Systern. **Typical System Configuration 4- Din Rail Mounted Fuse Holders,600VDC 30 AMP 1- Power Distribution Block 600VOIC 175AMP 1 - Bus Bar tmith UL lug Model SD 078641 6"Slofted Din Rail fastened using steel studs "Typical System Configuration 4- Din Rail Mounted Fuse Holders 600V1 30 AMP 4- Din it Mounted Terminal Blocks Bus Bars With U11 lug Conduit or fiffings, dase- i-s mntpr difnped T f -,affing locations M r Model Srj Q786-41, Ydred w-fth, lode[ S- 078:3-41, mledwiz.h Din Red rnouved fuse nidders, Din Rail mounted fuse hcklers- bus baT and power dIsn-ibuborl tf-ffninal hiodk-N and bus bars, Nook. RSTG- Enterprises, Inc . 2219 H-eimstead Road . Eau Cliare, W1 54703 For product information call 1(866) 367-7782 201 N. FRANKLIN ST. SUITE 2200 TAMPA, FL 33602 REVISIONS DESCRIPTION DATE REV INITIAL DESIGN 08104/2022 PROJECT NAME & ADDRESS N W 0 U') co Z Lli Uj co LU < cr, Z Z LL W 0 LL00 — U) 00 T- 0 Uj Lij LLj 0- N DRAWN BY ESR SHEET NAME EQUIPMENT SPECIFICATION SHEET SIZE ANSI B 11 " X 17" SHEET NUMBER PV-16