HomeMy WebLinkAbout22-4718City of Zephyrhillst�1�p
5335 Eighth Street
Zephyrhills, FL 33542
GR-0 471 g_ ®22
Phone: (813) 780-0020
Fax: (813) 780-0021
Issue Date: 09/01/2022
r
24 26 21 0090 00000 1110 3130 Moulden Hollow Drive
k
3t,w�.i,.:'�, 003, .? 3 >i^.-t
;
i. ,.., ,',? v �+�\ , .. t>-.,
�' i�t �4{t. icx, .ta= ,
Name: ANTHONY LAMBERTI Permit Type: Building General (Residential) Contractor: HOMETOWN POOLS AND
Class of Work: In Ground Swimming Pool PAVERS
Address: 3130 Moulden Hollow Dr Building Valuation: $40,000.00
ZEPHYRHILLS, FL 33540 Electrical Valuation: $15,000.00 ""
Mechanical Valuation: $1.00a:
Phone: (352) 437-9266 �-
Plumbing Valuation: $15,000.00
Total Valuation: $70,001.00
Total Fees: $705.00
Amount Paid: $705.00L o" a
Date Paid: 9/1/2022 2:41:23PM s..,,,, `,.• ..
INSTALLATION INGROUND SWIMMING POOL W/ PAVER DECK40 X 40
Building Plan Review Fee
Plumbing Permit Fee
Electrical Permit Fee
$120.00 Electrical Plan Review Fee
$115.00 Building Permit Fee
$115.00 Plumbing Plan Review Fee
$57.50
$240.00
$57.50
REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection, whichever is greater, for each subsequent reinspection.
Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies.
• •. •. ...... , i is . . .. •: •.: . ...
Complete Plans,Specifications add fee MustAccompany Application. lwork. beperformed in
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE
1
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
i . �■
Owner's Name or Phone Number 407 - 9 Z40(o
Owner's Address IS 110 IPAOkJeA.r "' Owner
Fee Simple Titleholder Name Owner Phone Number
Fee Simple Titleholder Address ADDRESS zA + y♦;a.
♦• D 1110. P.PERTY
DEMOLISH
F�r INSTALL
REPAIR
PROPOSED USE
SFR F-1
COMM OTHER
TYPE OF CONSTRUCTION
BLOCK E]
FRAME STEEL [5? .r
TAJo
POIDI Paver l y
DESCRIPTION ♦ OF tR
M
I W I [�� [��
BUILDING SIZE
x �p SQ FOOTAGE
HEIGHT
=BUILDING
VALUATION OF TOTAL CONSTRUCTION 70/ ow
M
...,.
OF •
ROOFING
SPECIALTY = OTHER
FINISHED=GAS
FLOOR ELEVATIONS
FLOOD ZONE AREA =YES NO
BUILDER
SIGNATURE
Address
%/
�
� IIIMIrr Ir �►
r
SIGNATJR S t TERED g Y� II NN f FEE CURREN YI t N ) h �f �y a
Add s - I's IS S+ License # [ a00 {d 2,474 J
PLUMBER a COMPANY
SIGNATURE REGISTERED Y / N FEE CURREN Y ( N
Address Or/ C` License#
MECHANICAL COMPANY __
SIGNATURE REGISTERED Y (NM FEE CURREN Y i N
Address License #
OTHER � COMPANY E _
SIGNATURE REGISTERED Y 1 N FEE CURREN Y 1 N —
Address License #
RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction,
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster, Site Work Permit for subdivisionsflarge projects
COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction.
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance
SIGN PERMIT Attach (2) sets of Engineered Plans.
*—PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner & Contractor sign back of application, notarized
If over $2500, a Notice of Commencement is required. (A/C upgrades over $7500)
— Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage)
Driveways -Not over Counter if on public roadways -needs ROW
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to'deed" restrictions" which may be more restrictive
than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions,
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they
may be required to be licensed in accordance with state and local regulations. If the contractor Is not licensed as required by law, both the owner and
contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements
may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009.
Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this
application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not property licensed and is
not entitled to permitting privileges in Pasco County.
TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or
expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that
such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery
Fees must be paid prior to receiving a 'certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final
power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior
to permit issuance in accordance with applicable Pasco County ordinances,
CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant,
have been provided with a copy of the 'Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of
Agriculture and Consumer Affairs. If the applicant is someone other than the "owner', I certify that I have obtained a copy of the above described
document and promise in good faith to deliver it to the 'owner" prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with
all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as
indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all
laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I
understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I
must take to be in compliance. Such agencies include but are not limited to:
- Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, WaterNVastewater Treatment.
- Southwest Florida Water Management District -Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
Army Corps of Engineers -Seawalls, Docks, Navigable Waterways.
Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency -Asbestos abatement,
- Federal Aviation Authority -Runways.
I understand that the following restrictions apply to the use of fill:
- Use of fill is not allowed in Flood Zone "V" unless expressly permitted.
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to
commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or
other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as
authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from
thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work
authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a
period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to
exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered
abandoned,
dal as luentilludilun.
Notary Public Notary Public
Commission No. 01 C1500
Commission No, 014 0195oo
_-GLe—An.'s -joan 4AWek-
ii is lens r°,
Name of Notary typed, printed or stamped Name of Notary typed, printed or stamped
'00 a Notary Public State of Florida
OPP Glennis M Daniels
My Commission Hi 019500
Expires 07108/2024
04'"Na GlennNotary is M PublicDaniels State of Florida
MY Commission HH 019500
Expires 07/08/2024
INSTR#2022170278OR BK10664PG1911 Page lofl
08/02/2022 10:04 AM Rept: 2486772 Roe: 10.00 DS: 0.00 IT: 0.00
Nikki Alvarez-Sowles, Esq., Pasco County Clerk & Comptroller
Perm" NO, �q-441-00qo-oolw-//Jo
NOTICE OF COMMENCEMENT
Ste" Of County Of :7!As5Q
THE UNDERSIGNED hereby gives mks tat Impmvement will be made to certain mal property, " in accordanos vft Chapter 713, Florida Statutes,
the kAwkV Information Is prvAdod In #ft Nollice of Commonownent
I Description of PmpWParcel kJontillicatiori No.
Sb)W Address:
WIR" f ,,
2. GwwW Description of Improvement shafctd?. �Lz
3. 1 or Less" k0ormation If the Losses contracted for the Improvement
01 —A 11
14,b 14Lu 0e; e= z0" Its
Address city tote
Interest In PmpmV.
Contmctw% Toleph on*No.: w!)
5. Surw.
Name
Address city State
Amount of Bond: S Tolia*mne No.:
6. Lander.
Name
Address Clty Fiat*
Landoes Telephone No.;
7. Pars" within the State of Florida des!"Ited by Ow owner upon whom notion or other documents may be served as VvAded by
Season 713.13(lXaXn Fiords Stallutes:
Name
Address CRY S
Telephone Number of DoWgriated Person:
Ste
8. In addition to h1moolil, the mw designates Of
— to rec*ve a copy of the LW%xls Notice as prodded in Section 713.13(lXb), Florida Statu
Telephone Number of Person or Entity Dod"ted by Owner
9. Expiration date of NoIas of CommencomeM (Me worstion date may not be before the completion of construc:000 and ffmi JpW"ymant to
ey an te
contractor, but will be one yew ftm the date of recording unless a different daft Is specilled):
WA04PUP; Ti. A'kV PW.49tM, .#&TF RY 7kAE O%tft-E"--2rn?, ldF- F-VII91TICIV OF THE NOTICE OF COMMINICEME
Under penalty of I declare that I he" read the fict"olng noldoes Of oommer*m~ W that tthe facts therein are Irus lo it* beat
of my know . Wge=be,W,
STATE OF FLORIDA
COUNTY OF PASCO L
Ignature of Owrw aaasAuthc
0 er .W rtr�adar
"ftww0rector brtnermanaw
4- - . i AwLeRIM O—wAer
Sighitory's Title/Ofilice
The ftnigohV insitument was solmowledged before me this It 5"offf
yj,_L, 2OZ; by
0- (typo of authoifty, e.g., ~, trust", otlorney In fad) for
�f � — hh" J -4— tnaburtent was executed).
Personal Kno" Produced Identification 0 Notary S10%ature
N�-' - Sri mjiig7a; ME=
Fir
wPd*18/bcWhQ44QC*W1mww@mwd_pc05304$
WITHLAC 00CHEE RIVER ELECTRIC
MD
MCO 0 !PE R A =TI V E, INN
Your Touchstone Friergay Partncr "ZI
...........
1 101111111 1
Date : July 18, 2022
Address 3130 Moulden Hollow Dr
M, mul Eff
Approved: Yes [_
N] No
If "No", reason:
MIMM
Approved by: Dale Antoine
1-imm, -tvz���
Date : July 18, 2022
Date: _July 18, 2022 —1
NOTE : This approval is only a confirniation that the described pool location conforms to the "National Electrical Code"
concerning clearances between pools and electrical conductors. For identification of W.R.E.C. facilities, notify
Sunshine State One -Call @ 1-800-432-4770 or 811.
P.O. Box 1278, San Antonio, FL 33576 Phone: (352) 588-5115 1 Fax: 352) 567-4376
INSTR#2022170278 OR BK10664 PG1911 Page 1 of 1
08102/2022 10:04 AM Rept: 2486772 Rec: 10.00 DS: 0.00 IT: 0.00
Nikki Alvarez-Sowles, Esq., Pasco County Clerk & Comptroller
All liiiilll
hafICE OF COMMENCEMENT
$let. f Floo-91 06 County of pAll
I
Orm 6MA,
-7 City
S. Surety:
Namo
Address
CRY
State
AmountofBond: S
Telal No.:
Name
City
Seta
Ad*m
Lerl Telephone No.:
7. Psmons will* ft State of Fl*fW& desIgnated by the owl upon whom notion or o#w docullvente may be served as provkled by
SecWn 71I3A3(iX*X) FWWe Statuteer.
city state
Telephone Number of Designated Person:
8. In adMon to hImeahl, the owner designates —of—
to rel a CM of ft Usnofs Notice as pll In Sell 71 3.13(1)(b} Florkle Sfttutes.
TelNumber of Person or Entity Designated by Owner
9. E*ftbon data of W*x of Comm (ft elpirellon date may not be before the complellon of consingdon end flnel Payment to the
contral but wM be one yew flan ft dated recording unless a dffWwd deft is specillel:1):
weln the
n olly go.1 -0y that I hl read the fareong nolice of commenoement wO lhett:h;e �fsft#W It we hm to
STATE OF FLORIDA
COUNTY OF PASCO
Ature Of Il 5FOl Lns*WFAW*rtW
TNGKXNM
The f0ml irshmWo was admowledglild beflom me this J)!�sy of gA&Y_, 20?jby _Q4rkbQOW L--1QM6!drab
83 owner 0(suill O.V~, haltel eftmey in fed)
—(nWn#ofpwVonb6W0f. -.711nabumentwooexeouteld).
t
1lllllllMLZ11" TI�Mk -W
9W]
Ill
0
WITHLAC00CHEE RIVER ELECTRIC
MD
K
070 P E "RA
Your Touchstone Energy' Partner
r1r1`00L CLEARANCE'APPROVAL-
I I
2
Approved: Yes X No
If "No", reason:
Date : July 18, 2022
Date : July 18, 2022
mr, =11` �,- !'1
NOTE : This approval is only a confirmation that the described pool location conforms to the "National Electrical Code"
concerning clearances between pools and electrical conductors. For identification of W.R.E.C. facilities, notify
Sunshine State One -Call @ 1-800-432-4770 or 811.
P.O. Box 1278, San Antonio, FL 33576 Phone: (352) 588-5115 / Fax: 352) 567-4376
a
n
m
0.4
9
m
M,j
CI
=III �►' a�.�ll.� � ��. ���"�"" '«
DESCRIPTION:
JOHIN R. BEACH ASSOCIATES. INC.
w
n
r- m
30
UNDERWATER SEAT
(OVTIONAL SWI04OUT
OR LADDER)
FOR ALL DEPTHS > 5 FT.
0 NOT DESIGNED FOR
DIVING OPTIONAL HANDRAIt
0 L(sw FAD
.s
MIN. BELOW WATER = 18 IN.
NO LIMITATION TO SHAPE
CO
GENERAL POOL & SPA PLAN
-
P(I" I"
AaIO FA' E E w'
fir_ Tr.Y=t...,,. WATERLINE
(DEEP END) (SHALLOW END)
i
t
I
SEP aj_
P v
PAVERS OR DECK
t
SKIMMER
(REQUIRED IF SPA
;f4in
PIT
STEM)
SPILLOVER
UCTION INLETS
R(SEE NOTES)
FROM TO
FI��LTTE�R PUMP
PLUMBING SPA PLAN
N.T.S.
0-4
a i "RJX� i
W
7
I
6° MIN.
i
POOL t
U.T.S.
EN
## (OPTONAL)
BOND BEA
a., (OPTIONAI
WALL #FLOOR:
#. CO#3 BARS NCRETE
DIRECTION.
#
# # #
IE _ i ` •'
r
SPA
DECK, BOND BEAM, WALL %0X FLOOR
* DESIGN, CONSTRUCTION AND WORKMANSHIP SHALL BE IN CONFORMITY WITH THE REQUIREMENTS OF
r
POOL CONTRACTOR IS RESPONSIBLE#. FURNISHING ALL DETAIL DESIGN REQUIREMENTSINCLUDING
TOTAL DYNAMIC HEAD FOR EACH INDIVIDUALPOOL IN ACCORDANCEFLORIDA BUILDING ;s
AND ALL CONSTRUCTION ODES INCLUDING PLUMBING, ELECTRICAL AND
- PIPING SHALL BE SCH, i, PVC NSF-PW.
SLIDES,r SHALL BE INSTALLED IN ACCORDANCE
SPECIFICATION.
- ALL POOLS SHALL BE PROVIDED WITH A LADDER OR STEPS IN THE SHALLOW END WHERE WATER DEPTH
EXCEEDS 24 IN. WHERE WATER DEPTH EXCEEDS 5 FT, THERE SHALL BE LADDERS, STAIRS OR UNDERWATER
BENCHES/SWtMOUTSDEEP END.
- PROVIDE A COMPLETE TURNOVER OF POOL WATER IN 12 HOURS OR LESS.
- FILTER SHALL HAVE AN AIR RELEASE.
- PUMPS 5 HP r1081.
TOTAL DYNAMIC HEAD DEVELOPED BY THE COMPLETE SYSTEM.
* PRESSURE FILTER SYSEMS WITH A CLEANABLE STRAINER OR SCREEN SHALL BE PROVIDED
POOOL AND CIRUCULATION PUMP(S) TO REMOVE SOLIDS,DEBRIS,#
INSTALLATION INSTRUCTIONS. SKIMMERS SHALL BE INSTALLED ON OF ONE PER
8W SQUARE FEET OF SURFACE OR FRACTION THEREOF, AND SHALL BE DESIGNED FOR A FLOW RATE OF AT
LEAST 25 GPM PER SKIMMER.
• APPROVED MANUFACTURED INLET FITTINGS FOR THE RETURN OF RECIRCULATED POOL WATER SHALL BE
PROVIDED ON THE BASIS OF AT LEAST ONE PER 3DO FT2 OF SURFACE AREA. WHERE MORE THAN ONE INLET IS
REQUIRED, THE SHORTESTDISTANCE BETWEEN ANY TWO REQUIRED
• HEATER SHALL MEET . OR UL 1261 OR
COMPLY• CIRCULATION SYSTEMS SHALL s EDITIONS OF i AND THE
POOL PIPING SHALL BE TESTED ANDPROVED TIGHT TO THE SATISFACTION;ADMINISTRATIVE
AUTHORITY, UNDERSTA11C WATER OR AIR PRESSURE TEST OF ;, 15 MINUTES.
• POOL PIPING SHALL BE DESIGNED SO THE WATER VELOCITY WILL NOT EXCEED 10 FPS FOR PRESSURE PIPING
• 8 FPS FOR•.. PIPING, MAIN SUCTIONOUTLET VELOCITYCOMPLY
RESIDENTIAL• #COMPLY
• WASTE WATER DISPOSAL REQUIREMENTS SHALL COMPLY WITH R4501.10.
• SUBMERGED OT14ER THAN SKIMMERS, WHEN USED, SHALL BE SIZED AND INSTALLED IN
SUBMERGEDACCORDANCE WITH THE LATEST PUBLISHED EDITIONS OF ANSI/APSP/ICC-7 AND ANSI/APSP-16,
• SUCTION OUT -LET• • ASSOCIATED
FITTINGS, FASTNERS r COMPONENTS SHALL BE TESTED AND CERTIFIED BY A THIRD -PARTY
ACCREDITED BY THE INTERNATIONAL LABORATORY ACCREDITATION COOPERATION (ILAC) TO TEST AND
CERTIFY PRODUCTS AS CONFORMING TO ANSI/APSP-16.
• DUAL OR MULTIPLE SUCTIONOUTLETS PIPED IN A SINGLE SUCTION SYSTEM THROUGHa COMMON SUCTION
LINE TO + ISOLATED BY VALVES.
OF THE SUCTION OUTLET COVER/GRATE OR LOCATED ON TWO (2) DIFFERENT PLANES. SUCTION OUTLETS
SHALL • DUAL SUCTION OUTLETS SHALL BE SEPERATED BY A MINIMUM Of 3 FT MEASURED FROM CENTER TO CENTER
REMOVABLE• SUCTION OUTLET FITTING FASTENERS SHALL BE NOT BE # OF •#
• THE MAX. WATER DEPTH SHALL BE 4 FT.
•MAX- SEAT DEPTH SHALL BE 28 IN.
• MAIL FLOOR SLOPE %1e12j.
• STEPS, SEATS, LADDERS, OR RECESSED TREADS SHALL BE
PROVIDED FOR DEPTH GREATER THAN 24.
• STEPS SHALL HAVE TREADS MIN. HORIZONTAL DEPTH OF 10
IN AND UNOBSTRUCTED WALKING SURFACE OF 240 IN',
RISERS SHALL HAVE A MAX. UNIFORM HEIGHT OF 12 IN;
BOTTOM RISER HEIGHT IS ALLOIAIED TO VARY.
• OPTIONAL HANDRAIL SHALL BE INSTALLED SO THEY CANNOT
BE REMOVED ED WITHOUT TOOLS.
• OPTIONAL SEATS OR BENCHES ARE NOT PROHIBITED FROM
BEING PART Of THE STEPS-
• THE SYSTEM SHALL BE DESIGNED TO TURN OVER THE ENTIRE
WATER CAPACITY AT A MfN. OF ONCE EVERY HOUR.
• MAX_ TEMPERATURE OF 104 DEGREES'°F_
• CIRCULATION SYSTEM PIPING SHALL BE SUBJECT TO AN
INDUCED STATIC HYDRAULIC PRESSURE TEST AT 25 PSI FOR
SO MINUTES OR AT THE TEST CONMITION SPECIFIED BY THE
AUTHORITY HAVING JURIICT
• ELECTRICAL EQUIPMENT WIRING AND INSTALLATION,
INCLUDING THE BONDING AND GROUNDING OF POOL
COMPONENTS SMALL COMPLY WITH CHAPTER 27 OF THE
FLORIDA BUILDING CODE — BUILDING & NEC 2017.
• A RECEPTACLE IS REQUIRED NOT LESS THAN 6 FT AND NOT
MORE THAN Zia FT FROM POOL WALL
• ALL RECEPTACLES WITHIN 20 FT OF POOL WALL SHALL HAVE
GFO PROTECTION.
• O`WERHEAD POWER OR RECEPTACLE ABOVE POOL OR WITHIN
5 FT FROM POOL WALL MUST BE INSTALLED AT LEAST 12 FT
ABOVE WATER LEVEL_
• UNDERWATER LUMINAIRES MOUNTED IN WALLS SHALL BE
INSTALLED WITH THE TOP OF THE WMINAIRE LENS NOT LESS
THAN 18 IN BELOW THE NORMAL WATER LEVEL OF THE
POOL.
CERTIFIEDIT HAS BEEN THAT THESE DESIGN
VS. 11019ri,101011
r # i
•
Haven Engineering LLC
4704 W. Price Ave., Tampa, FL 33611
SUCTION OUTELTS
TAMPERPROOF (SEE TES)
havenengineeringllc@gmaii.com
813.943.6950
Hometown Pools & Pavers
5 Lake Ray Dr.
Dade City, FL 33525
INLET
CLEANER LINE
Standard esi ental Pool
and/or Spa Design
0■FROM FILTER IF PRESSURE CLEANER
STATE OF
0 t Houston P.E. 86052