HomeMy WebLinkAbout22-4783City of Zephyrhills
. .... .. .... .. . . ......
.04"M
5335 Eighth Street
Zephyrhills, FL 33542
BAR-004783-2022
Phone: (813) 780-0020
Fax: (813) 780-0021
Issue Date: 10/05/2022
k=tt 0011471affirif"A M
10 26 21 0120 00000 0490
Name: STEVE & ELAINE PLOURDE
Address: 37350 Cornwall Dr
ZEPHYRHILLS, FL 33542
Phone: (864) 796-5777
Permit Type: Add/Alter (Residential)
Class of Work: Add/Alter Residential
Building Valuation: $7,000.00
Electrical Valuation: $1.00
Mechanical Valuation: $1.00
Plumbing Valuation: $1.00
Total Valuation: $7,003.00
Total Fees: $112.50
Amount Paid: $112.50
Date Paid: 10/5/2022 11:17:50AM
CONSTRUCT SCRN RM 176 SQ FT /EXISTING SLAB
37350 Cornwall Drive
Contractor: SUNSTATE ALUMINUMN IN
Building Permit Fee $75.00 Building Plan Review Fee
$37.50
REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection, whichever is greater, for each subsequent reinspection.
Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies.
IIIII 11111�1111 •1� III 111�1111111111111 III I
rt TTfT-T =— M3���E
Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
A 1
C- TRACTOR SIGNATURE PE IT OFFICEt)
101ERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIOK
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
813-780-0020 City of Zephyrhills Permit Application Fax-81 3-780-0021
Building Department
Date Received I / t — I Phone Contact for Perm
Owner's Name
1" I
Owner Phone Number
Owner's Address
jO
e, 33-�
Owner Phone Number
Fee Simple Titleholder Name
I
Owner Phone Number
JOBADDRESS l
SUBDIVISION "Mak PARCEL ID e9 6
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED e NEW CONSTR F—I ADD/ALT SIGN = DEMOLISH
INSTALL
REPAIR
PROPOSED USE
SFR
COMM OTHER
TYPE OF CONSTRUCTION
BLOCK
FRAME STEEL
DESCRIPTION OF WORK
C) 1k,
BUILDING SIZE SQFOOTAGE;HEIGHT
UILDING VALUATION OF TOTAL CONSTRUCTION
=ELECTRICAL 1$ AMP SERVICE PROGRESS ENERGY W. R. E. C.
1 =PLUMBING $
�=MECHANICAL VALUATION OF MECHANICAL INS2' 14� 0-1
GAS ROOFING 0 SPECIALTY = OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA YES NO
L X,
BUILDER COMPANY
SIGNATURE REGISTERED IT _] FEE CURREN I Y/N
Address License# aw in
ELECTRICIAN COMPANY E�;;;
SIGNATURE REGISTERED FEE CURREN
Address License #
PLUMBER COMPANY
SIGNATURE REGISTERED L_YI_N] FEE CURREN I Y/N
Address License#
MECHANICAL COMPANY
SIGNATURE REGISTERED L_YLNj FEE CURREN
Address License #
OTHER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREN I Y/N
Address License#
RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction,
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans wl Silt Fence installed,
Sanitary Facilities & I dumpster; Site Work Permit for subdivisions/large projects
COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction.
Minimum ten (10) working days after submittal date. Required onste, Construction Plans, Stormwater Plans wl Silt Fence installed,
Sanitary Facilities & 1 dumpster, Site Work Permit for all new projects. All commercial requirements must meet compliance
SIGN PERMIT Attach (2) sets of Engineered Plans.
****PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner & Contractor sign back of application, notarized
If over $2500, a Notice of Commencement is required. (A/C upgrades over $7500)
Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage)
Driveways -Not over Counter if on public roadways..needs ROW
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or
final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances,
CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I
certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law —Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the "owner" prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be per -formed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
- Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment,
- Southwest Florida Water Management District -Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers -Seawalls, Docks, Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency -Asbestos abatement.
- Federal Aviation Authority -Runways.
I understand that the following restrictions apply to the use of fill:
Use of fill is not allowed in Flood Zone "V" unless expressly permitted.
If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension
may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate
justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
FLORIDA JURAT (F.S. 111M
OWNER OR AGENT C,DNTRACTOR/4_,�W_2�4 I"
Subscribed and sworn t; —(or affirmed)lefore me this S I Je �,.I;,v ffir)ied) before met this
by
's are p
Who Ware personally known to me or has/have produced o is are pe onally knovyrr to me or has/have produced
as identification. as identification.
ry Public
Commission
Name of Notary typed, printed or stamped
Name of Notary typed, printed or stamped
INSTR# LO222O9699 OR 13KI0696 PG 1 70 Page 1 of 1
09/22/2022 01:18 PM Ropt: 2506655 Rec: 10.00 DS: 0.00 IT: 0.00
Nikki Alvarez-Sowles, Esq., Pasco County Clerk & Comptroller �+ 1
Permit
Parcel ID No
NOTICE OF COMMENCEMENT
State of t /D!i !T fj® County of elen f U
THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property, and In accordance with Chapter 713, Florida Statutes.
the Ong Information is provided In We Notice of Commencement
1. Description of Property: Parcel IdentlficgQon No. 0/-. O — 4 Ci
Street Address: 2Z. 41
2, General Description of Improvement
3. Owner information or Lessee information If the Lessee contracted for the improvement
�%3 SiNamB/jd/nr41Q /// e 7_Pk,Fil
Addroaa �, City ' state
Interest In Property: l,!%J f
Name of Fee Simple Titleholder.
(If different from Owner listed above)
Add 4. n tar �i x �a �u tvr i rr w � City state
Name
Address 754
7 C city state
Contractor's Telephone No.: U 75 Qo
5. Surety:
Address City State
Amount of Bond: $ Telephone No.:
6. Lender.
Address City State
Lenders Telephone No.:
7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by
Section 713.13(1Xa)(7), Florida Statutes:
Address City state
Telephone Number of Designated Person:
8. in addition to himself, the owner designates of
to receive a copy of the Llenors Notice as provided in Section 713.13(1 Xb), Florida Statutes.
Telephone Number of Person or Entity Designated by Owner:
9. Expiration date of Notice of Commencement (the expiration date may not be before tine completion of construction and final payment to the
contractor, but will be one year from the date of recording unless a different date is specified):
OF THE NOTICE OF COMMENCEMENT
3.13, FLORIDA STATUTES, AND CAN
TICE OF COMMENCEMENT MUST BE
END TO OBTAIN FINANCING, CONSULT_ _
—1. IV 4G.1---N 11--- I v-1— V11,44V,wnvV 1-11 vv „v,.. v, wvonor,aya�muv,.
Under penalty of perjury, I declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best
of my knowledge and belief.
STATE OF FLORIDA
COUNTY OF PASCO L
S ,lure of Owner or Lessee, or Owners or Lesaee's Authorized
Ofilcar/Dlrector/PartneriManager
Signatory's Tttia/OMce
The foregoing instrument was acknowledged before me this day of,
a8 a/s (type of authority, e.g., officer. trustee, allomay in fact) for
(name party on behalf of wjnom In rrygnt s e eel).
Personally Known ® Q8 Produce1jidendlicationI
Notary Signature
Type of idettiflrstion Produced Y r f Name (Print)
SHIRDEti K. DEL COTTO
uM"NGG
:.:
is
MYt
EXPIRES: June 25, 2024
„h°''
Bortdcd ilvu Notary f+
w
wr
E w ++
•
i
e •
• .
tr
01
wpdauVbcshwtloecommencenent_ >oO53048
c
General Notes
A. CONCRETE & FOUNDATION DESIGN:
I ALL CONCRETE GRADE BEAMS AND FOOTINGS SHALL BE 3000
PSI MINIMUM.
2 ALL CONCRETE FILLED SUPPORTED SLABS SHALL BE 2500 PSI
MINIMUM, 3 1/2" NOMINAL, THICKNESS.
3. 3000 PSI FIBERMESH (3/4" PER CUBIC YARD MIN) MEETING
APPROPRIATE ACI AND ASTM REQUIREMENTS MAY BE USED
IN LIEU OF WELDED WIRE MESH
4, ALL SLABS ON GRADE SHALL BE 4" THICK WITH FIBERMESH.
'TERMITE TREATMENT OF SOIL BENEATH SLAB IS NOT
REQUIRED IF SLAB DOES NOT ABUT A WOOD FRAME
STRUCTURE. NO WOOD FRAME STRUCTURE MAY BE BUILT
ADJACENT TO OR ON TOP OF A SLAB WITHOUT TREATING THE
SOIL FOR WOOD DESTROYING ORGANISMS,
5. ALL REINFORCING SHALL CONFORM TO ASTM A615, BE GRADE
60 (60 KSI MIN,) DEFORMED BARS, 93 BARS MAY BE GRADE 40
6. ALL OVER POUR CONCRETE FILLED SUPPORTED SLABS SHALL.,
BE 3000 PSI MIN., 2" MINIMUM. THICKNESS.
T SOIL BEARING PRESSURE SHALL BE A MINIMUM OF 1500 PSF.
8. THE CONCRETE SHALL CONFORM TO ASTM C94 FOR THE
FOLLOWING:
OPC (PORTLAND CEMENT TYPE I,- ASTM C 150).
AGGREGATES - 96 STONE, ASTM C 33 SIZE NO.67 LESS THAN
3/4".
AIR ENTRAINING +/- 1% - ASTM C 260.
WATER REDUCING AGENT - ASTM C 494.
CLEAN POTABLE WATER.
OTHER ADMIXTURES SHALL NOT BE PERMITTED.
9. METAL WELDED WIRE SHALL CONFORM TO ASTM A 185,
10. PREPARE & PLACE CONCRETE ACCORDING TO AMERICAN
CONCRETE INSTITUTE MANUAL STANDARD PRACTICE, PART L
2, & 3 ALONG WITH HOT WEATHER CONDITIONS
RECOMMENDATIONS.
11. IF UTILIZING EXISTING CONCRETE FOR FOUNDATION,
CONCRETE SHALL BE A MINIMUM OF 4" IN THICKNESS,
VISIBLY FREE OF ANY STRUCTURAL EXCESSIVE CRACKING,
SPALLING OR OTHER DETERIORATION.
B. MASONRY:
i CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD
HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON
TYPE M OR S MORTAR.
2.ALL MORTAR SHALL BE OF TYPE M OR S.
3_ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE
MAXIMUM COARSE AGGREGATE SIZE OF 3/8".
4.PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING
REINFORCEMENT WHEN GROUT POUR EXCEEDS Y-0° IN
HEIGHT.
C. ALUMINUM:
I . ALL STRUCTURAL ALUMINUM SHALL CONFORM TO THE.
MINIMUM REQUIREMENTS OF 6005-T5 FOR ALLOY WITH A
MINIMUM THICKNESS OF 0,040" FOR SUPPORTING MEMBERS.
2, WHERE KICK PLATES ARE USED A MINIMUM THICKNESS OF
0.024" SHALL APPLY.
3, STRUCTURAL ALUMINUM DESIGN CONFORMS TO "PART 1-A -
SPECIFICATIONS FOR ALUMINUM STRUCTURES - ALLOWABLE
STRESS DESIGN" OR "PART I-B - SPECIFICATIONS FOR
ALUMINUM STRUCTURES - BUILDING LOAD AND RESISTANCE
FACTOR DESIGN" OF THE CURRENT ALUMINUM DESIGN
MANUAL PREPARED BY THE ALUMINUM ASSOCIATION,
INC.WASHINGTON D.C_ THE FLORIDA BUILDING CODE, 7TH
EDITION ( CHAPTER 16 STRUCTURAL DESIGN & CHAPTER 20
ALUMINUM).
4. WHERE ALUMINUM COMES INTO CONTACT WITH STEEL, OR
PRESSURE TREATED LUMBER PROVIDE DIELECTRIC
SEPARATION.
5. ALUMINUM MEMBERS SHALL BE STITCHED WITH NO LESS
THAN #10 SMS 6" FROM THE ENDS AND 12" ON CENTER, IF
USING 512 SPACING MAY BE 24" ON CENTER.
6. VINYL AND ACRYLIC PANELS SHALL BE REMOVABLE THEY
SHALL BE IDENTIFIED WITH A DECAL ESSENTIALLY STATING
"REMOVABLE PANEL SHALL BE REMOVED WHEN WIND
SPEEDS EXCEED 75 MPH" DECAL SHALL BE PLACED SO IT IS
VISIBLE WHEN PANEL IS INSTALLED.
D. FASTENERS:
i, ALI, LAG BOLTS SHALL CONFORM TO STAINLESS STEEL TYPE
300 18-8, WITH STANDARD FLAT WASHER UNLESS
MANUFACTURER GALVANIZES BOLTS SPECIFIES FOR USE
WITH ACQ PRESSURETREATED ED WOOD.
2_ HEX BOLTS HAS TO BE ASTM A 325, PLATED WITH STANDARD
FLAT WASHERS AND NUTS.
3_ ALL CONCRETE SCREWS SHALL BE, SIMPSON, HILTI, RAWL,
TAPCON, REDHEAD, DYNABOLT, OR APPROVED EQUAL,
4_ ALL METAL TIES AND ASSOCIATED ACCESSORIES SHALL BE
HOT DIPPED GALVANIZ,,,,ED.
5. ALL LAG BOLTS SHALL HAVE A MINIMUM EMBEDMENT OF 8X
BOLT DIAMETER INTO STRUCTURAL FRAMING (G=.42 MIN.).
6. LAG BOLTS AND SCREWS INTO WOOD FRAMING SHALL BE
PROVIDED WITH PILOT HOLES HAVING A DIAMETER NOT
GREATER THAN 70 PERCENT OF THE THREAD DIAMETER OF
THE BOLT OR SCREW. ALL LAG BOLTS AND SCREWS SHALL BE
INSERTED IN PILOT HOLES BY TURNING AND UNDER NO
CIRCUMSTANCES BY DRIVING WITH A HAMMER
7. ALL EXPANSION ANCHORS SHALL BE DESIGNED IN
ACCORDANCE WITH THE SPECIFIC MANUFACTURER'S
REQUIREMENTS AND ALLOWABLE LOADS AND SHALL ONLY
BE APPLIED IN CONDITIONS ACCEPTABLE TO
MANUFACTURER. FASTENERS SHALL BE A MINIMUM OF SAE
GRADE #5 OR BETTER ZINC PLATED.
8, ALL FASTENERS CONNECTING ALUMINUM COMPONENTS OR
PRESSURE TREATED LUMBER ARE STAINLESS STEEL TYPE 300
18-8, UNLESS MANUFACTURER GALVANIZED BOLTS SPECIFIES
FOR USE WITH ACQ PRESSURE TREATED WOOD, OR
OTHERWISE NOTED ON PLANS.
9. ALL FASTENERS SHALL COMPLY WITH ASTM A153.
10, ALL CONNECTORS SHALL COMPLY WITH ASTM A653 CLASS
G-185,
11.FOR SMS, THE MINIMUM CENTER -TO -CENTER SPACING SHALL
BE 3/4" AND MINIMUM CENTER -TO -EDGE SHALL BE 1/2"
UNLESS NOTED OTHERWISE.
E. REFERENCE STANDARDS:
ASTM E 119
ASTM E 1300
ASCE 7 -16
AA ASM35, AND SPEC. FOR ALUMINUM PART 1-A, & 1-B
ASTM C94
ASTM CI50
ASTM C33
ASTM C260
ASTM C494
ASTM A615
ASTM A185
FLORIDA BUILDING CODE (CHAPTERS 16,20 AND 23)
7TH EDITION
CURRENT ALUMINUM DESIGN MANUAL
F. ABBREVIATIONS:
THE FOLLOWING LIST OF ABBREVIATIONS IS NOT INTENDED
TO REPRESENT ALL THOSE USED ON THESE DRAWINGS, BUT
TO SUPPLEMENT THE MORE COMMON ABBREVIATIONS.
1. TYP -- TYPICAL
2. SIM--SIMILAR
3. UON -- UNLESS OTHERWISE NOTED
4. CONT-- CONTINUOUS
5. VIF -- VERIFY IN FIELD
G. RESPONSIBILITY:
1. ALL SITE WORK SHALL BE PERFORMED BY A LICENSED
CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING
CODES, LOCAL ORDINANCES, ETC.
2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND DETAILS,
NOTIFYING ENGINEER OF ANY DISCREPANCIES BETWEEN
DRAWINGS, FABRICATED ITEMS, OR ACTUAL FIELD
CONDITIONS.
3. THESE DRAWINGS REPRESENT THE ACCEPTABILITY OF THE
'SUNROOM' ROOM ADDITION ELEMENTS AS PROVIDED BY THE
CONTRACTOR.
4. ALL DETAILS ON THESE DRAWINGS ARE ENGINEERED BASED
ON INFORMATION PROVIDED BY THE CONTRACTOR AND
MANUFACTURER,
5. ANY DETAILS NOT SHOWN ARE TO BE ENGINEERED BY A
LICENSED P.E. IN ACCORDANCE WITH STANDARD
ENGINEERING PRACTICES.
H. MISCELLANEOUS:
1. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A
MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME
WITHOUT A MANUFACTURER'S HOST BEAM.
IF NO HOST BEAM IS PRESENT A SEPARATE 4TH WALL SUPPORT
SYSTEM SHALL BE ENGINEERED SO THAT NO ADDITIONAL
LOADING IS PLACED ON THE MANUFACTURED HOME.
2. IF ENCLOSURE CONTAINS A SWIMMING POOL OR SPA, THE
ENCLOSURE SHALL COMPLY WITH RESIDENTIAL SWIMMING
BARRIER REQUIREMENTS OF THE FBC 7TH EDITION
R 4501.17.1 IN ITS ENTIRETY.
3. DOOR LOCATIONS MAY BE DETERMINED IN THE FIELD BY
CONTRACTOR.
4. IF PAVERS ARE UNDER ALUMINUM MEMBERS THEY SHALL
HAVE EPDXY ADHESIVE TO CONCRETE OR IF USING GROUT,
ENSURE BONDING AGENT IS USED FIRST.
S. SCREENING MATERIAL SHALL BE 18X14X0.013 OR
EQUIVALENT DENSITY SCREEN MESH ONLY UNLESS NOTED
OTHERWISE.
6. EMERGENCY ESCAPE & RESCUE OPENING PER FBC R310.1
SHALL BE VERIFIED BY CONTRACTOR & BUILDING OFFICIAL
7. ENCLOSED ADDITIONS TO MANUFACTURED HOMES SHALL NOT
CHANGE THE EXIT FACILITIES FOR EGRESS PER HUD 3280,105, (a)
THROUGH (a)(2)(iv), SO THAT THE DISTANCE TO EXIT DIRECTLY
OUTSIDE FROM ALL BEDROOMS IS LESS THAN 35', AND, SO THAT
TWO EXITS DIRECTLY OUTSIDE ARE STILL MAINTAINED. A CARPORT
OR SCREEN ROOM SHALL BE CONSIDERED AS OUTSIDE. NON -HABITABLE
SUNROOMS OR HABITABLE LIVING SPACE MAY BE ADDED WHERE AN EXIT
DOOR WAS LOCATED AS LONG AS A NEW EXIT DOOR IS ADDED AND MEETS
THE REQUIREMENTS OF HUD 3280.105,
DESIGN DATA:
1. ULTIMATE DESIGN WIND SPEED Vult, (3 SECOND GUST): 130 MPH
NOMINAL DESIGN WIND SPEED Vasd: 101 MPH
2. RISK CATEGORY: I
3. WIND EXPOSURE: B
4, INTERNAL COEFFICIENT:
SCREEN ROOM (OPEN STRUCTURE): 0.0
S. WIND LOADS:
FACTOR APPLIED TO WIND LOADS FOR ALLOWABLE STRESS DESIGN: 0.6
SOLID ROOF (MWFRS): 20 PSF
SCREEN WALLS: 23 PSF
COMPONENT & CLADDING PRESSURES:
ROOF ZONE 1: 12.4/-48.4 PSF, ZONE 2: 12.4/-63.9 PSF, ZONE 3: 12.4/-87.1 PSF
6. FOUNDATIONS PER "A" OF GENERAL NOTES AND SITE SPECIFIC DETAIL.
EXISTING 4" CONCRETE SLAB, 2500 PSI CONCRETE W/ 6"X6"-410WWM OR 3000
PSI FIBERMESH AND FOOTER SHALL BE ADEQUATE TO RESIST THE UPLOADS FOR
THE PROPOSED STRUCTURE.
7. SOLID ROOF TYPE: 3"X4W COMPOSITE PANELS, FL 7561 OR EQUIV,
ALUMINUM STRUCTURAL MEMBERS
HOLLOW SECTIONS
2 x 2:---------------------------------------2"
x 2" x 0.044"
3 x 2:---------------------------------------3"
x 2" x 0.050'
2 x 3:---------------------------------------2"
x 3" x 0.050„
2 x 3:---------------------------------------2"
x 3" x 0.070„
2 x 4:---------------------------------------2"
x 4" x 0.050„
2 x 5:---------------------------------------2"
x 5" x 0.050„
3 x 3:---------------------------------------3
x 3" x 0.072„
3 x 3:---------------------------------------3
x 3" x 0.093"
3 x 3:---------------------------------------3
x 3" x 0.125„
4 x 4:---------------------------------------4
x 4" x 0.125"
OPEN BACK SECTIONS
1 x 2: ----------------------------------------
1" x 2" x 0.040„
1 x 3:----------------------------------------1"
x 3" x 0.045„
SNAP SECTIONS
2 x 2 Snap :----------------------------------2"
x 2" x 0.045"
2 x 3 Snap:
---------------------------------2" x 3" x 0.050"
2 x 4 Snap:---------------------------------
2" x 4" x 0.045"
SELF MATING (SMB)
2 x 4 SMB:----------------------
2" x 4" x 0.044" x 0.100"
2 x 5 SMB:----------------------
2" x 5" x 0.050" x 0.118"
2 x 6 SMB:---------------------
2" x 6" x 0.050" x 0.120"
2 x 7 SMB:----------------------
2" x 7" x 0,057" x 0,120"
2 x 8 SMB:---------------------
2" x 8" x 0.072" x 0.224"
2 x 9 SMB:----------------------
2" x 9" x 0.072" x 0.224"
2 x 10 SMB:-------------------
2" x 10" x 0.092" x 0.374"
1 HEREBY CERTIFY THAT I HAVE REVIEWED
THIS PLAN AND FOUND IT TO BE IN
COMPLIANCE WITH ASCE 7-16 AND FBC 7TH
EDITION RESY Rft4TIALIANP, XISTING
BUhLDi�� � F 0,���
S
STATE OF'11> �
d7jttl1t991@9&1111\\l
PROFESSIONAL ENGINEER SEAL
ENGINEER OF RECORD
David W. Smith P.E.
FLORIDA LICENSE NUMBER: 53608
Thomas L. Hanson P.E.
FLORIDA LICENSE NUMBER: 38654
Ian J. Foster P.E.
FLORIDA LICENSE NUMBER: 93654
Joel Falardeau P.E.
FLORIDA LICENSE NUMBER: 70667
Erik Stuart P.E.
FLORIDA LICENSE NUMBER: 77605
FBC Plans & Engineering
Services, Inc.
6272 Abbott Station Drive Unit 101
Zephyrhills, fl. 33542
Phone:(813)788-5314
Fax:1-(866)-824-7894
Email: erb@fbcplans.com
Website: www.fbcplans.com
C,O.A. - 429054
DATE: 09/08/2022
DRAWN BY: DENNIS W. DUNN
4, - �499i;
K �„ REVISION: DATE:
.TfY � '` 4
RO 1
> I";` -' rr „.�II`.1 ✓ x �� :fir
U gym' { U, n, RO 2
F 7V`$ p, RO3
RO 4
a
'h�°' J
JOB # 22 09XX XXX
JOB NAME & ADDRESS:
PLOURDE
37350 CORNWALL DR.
y "
ZEPHYRHILLS, FL. 33542
3
., ,� ,
r �,-- �
CONTRACTOR:
SUNSTATE ALUMINUM
INDEX:
S-9 GENERAL NOTES
S-2 PLANS AND ELEVATIONS
S-3 SCREEN ROOM DETAILS
S-4 SCREEN ROOM DETAILS
MCI
NFRINION&MV "Re
— ( s
EXISTING
HOME
1 1 '2X3 2X3 i
EXISTING
HOUSE OVERHANG LU
(D X
12X3 0
PROPOSED
x SCREEN ROOM
V) 2X3�
12X3
X
J
2X3
EXISTING
HOME I?
a,
4' 1 4' 1 4' 1 4'
PROPOSED
LEDGER BOARD (WOOD OR ALUMINUM)
TO RUN ALONG RAKE OF COMPOSITE
ROOF, UP AND DOWN, BOTH SIDES
----PROPOSED
3" X ' 024" COMPOSITE PANEL
ROOF FL 7561 OR EQUIV.
W/ GLUE DOWN SHINGLES
--EXISTING
CONCRETE SLAB W/ FOOTER
2X6 SMB
RIDGE
PROPOSED
_L3" X.02�4" COMPOSITE PANEL
0 ROOF FL 7561 OR EQUIV.
0 W W/ GLUE
GLUE DOWN SHINGLES
r —2X3
I 2X2 MIN. 11 2X2 MIN. L 2X2 MIN, 11 2X2 MIN
L1X2 MIN 115X2 MIN1 EX2 MIN:] 1X2 MIN
PROPOSED EXISTI[IG CONCREJ SLAB AND FtOTER
ALUMINUM COIL KICK PLATE 41 4' 4' 4'_
TYPICAL
16,
REAR ELEVATION
0
I HEREBY CERTIFY THAT I HAVE REVIEWED
THIS PLAN AND FOUND IT TO BE IN
COMPLIANCE WITH ASCE 7-16 AND FBC 7TH
EDITION RESJYNJ'fji��,4N1) EXISTING
F 0 S
I
654
% OF
1111�1111SIO6 NA-
f11111111"110
PROFESSIONAL ENGINEER SEAL
ENGINEER OF RECORD
David W. Smith P.E.
FLORIDA LICENSE NUMBER: 53608
Thomas L. Hanson P.E.
FLORIDA LICENSE NUMBER: 38654
Ian J. Foster P.E.
FLORIDA LICENSE NUMBER: 93654
Joel Falardeau P.E.
FLORIDA LICENSE NUMBER: 70667
Erik Stuart P.E.
FLORIDA LICENSE NUMBER: 77605
FBC Plans & Engineering
Services, Inc.
6272 Abbott Station Drive Unit 101
Zephyrhills, fl. 33542
Phone; (813)788-5314
Fax: 1-(866)-824-7894
Email: erb9fbcpIans.com
Website: www.fbeplans.com
C.O.A. - #29054
DATE: 09/08/2022
DRAWN BY: DENNIS W. DUNN
REVISION: DATE:
RO I
RO 2
RO 3
RO 4
JOB# 2209XX — XXX
1013 NAME &ADDRESS:
PLOURDE
37350 CORNWALL DR.
ZEPHYRHILLS, FL. 33542
SUNSTATE ALUMINUM
PLANS AND ELEVATIONS
S-2
#10 TEK SCREW AND 1-1/4"0
#10 TEK SCREW AND 1-1/4"0
1 HEREBY CERTIFY THAT I HAVE REVIEWED
NEOPRENE WASHER AT 8" O.C. (USE
COMPOSITE NEOPRENE WASHER AT 8" O.C. (USE
COMPOSITE
THIS PLAN AND FOUND IT TO BE IN
COMPLIANCE WITH ASCE AND FBc 7TH
ALUMINUM RIDGE CAP
FASTEN COMPOSITE PANEL TO
SCREW LENGTH EQUAL TO COMPOSITE
PANEL ROOF SCREW LENGTH EQUAL TO COMPOSITE
PANEL ROOF
EDITION I�>���tl>£AIYktip�F,XISTING
P E
FLASHING FASTENED TO
BEAM W/ #10 TEK SCREW AND 1-1/4"0
PANEL THICKNESS PLUS 1" MIN.)
PANEL THICKNESS PLUS 1" MIN.)
BUIL (�
R
COMPOSITE PANEL W/#8 X 3/4"
NEOPRENE WASHER AT 8" O.C. (USE
TEK SCREW AT 12" O.C.
SCREW LENGTH EQUAL TO COMPOSITE
0 S
PANEL THICKNESS PLUS 1" MIN.)
- - -
_ 34
CE RpOF
COMPOSlTS ROpp
- — — — - - —
—
47
pO�pOgl
2X3 PATIO
2X3 PATIO
OF
EDGE / END BEAM
ATE a>
EDGE/END BEAM
2X6 SMB
RIDGE BEAM
(3) 3/8" THRU BOLTS,
WASHERS, AND NUTS,
2X3 UPRIGHT
2" X 2" X 0.125" ANGLE
W/ (3) #10 X 3/4" TEK SCREW
>, t O R VD
�ii �° `.....°' t
S10
CORROSION RESISTANT
j
EACH LEG, EACH SIDE OF UPRIGHT
//,/e
t�tttaG
ALUMINUM POST
INTO SCREW OSSREW
2X3 UPRIGHT
PROFESSIONAL
ESSIO NAL ENGI NEER SEAL
PER PLAN
it
EXISTING
WOOD FRAME HOM
LEDGER BOARD (WOOD OR ALUM.)
ATTACH TO WOOD WALL W/ (2) 1/4"0
LAG SCREWS AT EACH STUD 16" O.C.
W/ 2-1/2" EMBEDMENT MIN.
COMPOSITE PANEL ATTACHED
TO HEADER CHANNEL W/ #10 X 3/4"
TEK SCREW AND VO NEOPRENE
WASHER AT 8" O.C. TOP AND BOTTOM
APPLY FLASHING AT WALL AND ATTACH
TO COMPOSITE PANEL W/ #8 X 3/4" TEK
SCREW AT 12" O.C. CAULK ALL SEAMS
OR STRIP SEALANT BETWEEN WALL
AND HEADER CHANNEL
FASTEN HEADER CHANNEL
TO WOOD WALL WITH 1/4"0 LAG
SCREW AT EACH STUD 16" O.C.
W/ 2-1/2" EMBEDMENT MIN,
pit I NJ 9 04 11120 1A were]• 1 k
sr' .*• �s
i 119 a
OPTION (INTERNAL) OPTION (EXTERNAL)
ATTACH RIDGE BEAM TO LEDGER
BOARD PER'BEAM TO ALUMINUM' OR
'BEAM TO WOOD' CONNECTION DETAILS
ATTACH SHINGLES TO COMPOSITE ROOF WITH
PL 2000 PREMIUM ADHESIVE OR EQUIV. AND
RIDGE BEAM PROVIDE (2) 3/8" TO 1/2" THICK CONTINUOUS
PER PLAN ADHESIVE LINES PER SHINGLE SPACED 4"-6" APART.
ASPHALT -OR-
SHINGLE ADHESIVE MEMBRANE APPLIED TO METAL, SHINGLES
SCREWED OR NAILED THROUGH MEMBRANE PER NOTE.
COMPOSITE STANDARD ROOFING NAIL
PANEL ROOF �'� �, OR WAFER HEAD SCREW
COMPOSITE p (6 PER SHINGLE)
PANEL ROOF
NOTES:
1. FOR STARTER ROWS, ADHESIVE LINE SHALL
—0.060" MIN. BE PLACED WITHIN 1" OF PANEL EDGE.
HEADER CHANNEL 2. ASPHALT SHINGLES ADDED FOR AESTHETIC PURPOSES.
SCREEN ROOM SHINGLE DETAIL
CONNECTIONS TO HOST WOOD
2X3—11
��UPRIGHT 10
r-
2" X 2" X 0.125" ANGLE
(2) #12 X 3/4" TEK SCREW
FASTENING UPRIGHT TO
ANGLE IF 1X2 O.B. USED OR
(3) #12 X 3/4" TEK SCREW
IF 1X3 O.B. USED
(TYPICAL EACH SIDE)
1X2 OR 1X3 O.B. BASE MEMBER
(TYPICAL EACH SIDE)
(1) 3/8" O CONCRETE SCREW
ANCHOR THRU ANGLE AND O.B.
INTO CONCRETE AS SHOWN OR
THRU ANGLE INTO CONCRETE AND
1/4" O CONCRETE SCREW ANCHOR
THRU O.B. 6" FROM ENDS AND
24" O.C. BETWEEN UPRIGHTS.
MIN. EMBEDMENT SHALL BE 2-3/4"
AND 3" EDGE DISTANCE MIN.
(TYPICAL EACH SIDE)
(2) 3/8"0 MACHINE BOLTS,
NUTS AND WASHERS OR
(4) #14 X 3/4" TEK SCREWS EACH SIDE
EXTERNAL BASE
OPTION 2
ALUMINUM 3X3 POST
1K1TPRAIAI RACP
VrIJUN 1
11 GA. INTERNAL ALUMINUM BASE
PREDRILL VERTICAL FLANGES
2" X 2" X .125" ANGLES EXTERNAL
OR EQUIVALENT POST BASE
(4) 1/4"0 CONCRETE ANCHORS
W/ 3" EMBEDMENT, 3" MIN. EDGE
(2) 3/8"0 CONCRETE ANCHORS PER
DISTANCE AND 2" MIN. SPACING
EXTERNAL FLANGE WITH 2" O.C. SPACING,
2-3/4" MIN. EMBEDMENT AND 3" MIN.
CONCRETE EDGE DISTANCE
CONCRETE.
4
3X3 POST CONNECTION TO CONCRETE DETAIL
ENGINEER OF RECORD
David W. Smith P.E.
FLORIDA LICENSE NUMBER: 53608
Thomas L. Hanson P.E.
FLORIDA LICENSE NUMBER: 38654
Ian J. Foster P.E.
FLORIDA LICENSE NUMBER: 93654
Joel Falardeau P.E.
FLORIDA LICENSE NUMBER: 70667
Erik Stuart P.E.
FLORIDA LICENSE NUMBER: 77605
FBC Plans & Engineering
Services, Inc.
6272 Abbott Station Drive Unit 101
Zephyrhills, fl. 33542
Phone:(813)788-5314
Fax: 1-(866)-824-7894
Email: erb@fbcplans.coni
Website: www.fbcplans.com
C.O.A. - #29054
I DATE: 09/08/2022 1
I DRAWN BY: DENNIS W. DUNN I
I REVISION: I DATE: I
JOB ' I`
i k_ 11 rfV
PLOURDE
37350 CORNWALL DR.
ZEPHYRHILLS, FL. 33542
CONTRACTOR:
SCREEN ROOM
DETAILS
-3
ALUMINUM
POST
PER PLAN
FASTEN RECEIVING CHANNEL
TO SMB W/ #10 X 3/4" TEK SCREW
(1 SCREW PER INCH OF BEAM HEIGHT)
FASTEN SMB TO RECEIVING
STAGGERED, BOTH SIDES
CHANNEL W/ #10 X 3/4" TEK SCREW
1-1/2" X 2-1/8" K 1-1/2" X 0.062"
(1 PER INCH OF BEAM HEIGHT)
INTERNAL OR EXTERNAL
STAGGERED, BOTH SIDES
RECEIVING CHANNEL
— --
---
o
2X SMB PER PLAN
°
°
0
� Z
2X SMB PER PLAN
0
°
°
z Q
o
-- —
°
d
W
o z
.062 MIN. RECEIVING CHANNEL
¢ IL
FASTEN RECEIVING CHANNEL
o 2
FASTENED TO POST W/ #10 X 3/4" TEK
TO STRUCTURAL WALL MEMBER
�: 9
SCREW (1 PER INCH OF BEAM
WITH 1/4"0 X 2" LAG SCREW
HEIGHT) STAGGERED
(1 SCREW PER 2INCHES OF
BEAM TO ALUMINUM CONNECTION
BEAMAMHEIGHT)
BEAM TO WOOD CONNECTION
EXISTING WOOD
®® FRAME WALL
2X EDGE /END BEAM
PER PLAN
]
Q'17=OLAG SCREW
9
W/ 1-1/2" EMBEDMENT
MIN. 6" FROM TOP AND
2" X 2" X 1/8" X 'BEAM DEPTH'
BOTTOM AND 24" O.C.
RECEIVING CHANNEL
W/ (1) 1/4" LAG SCREW
NM
W/ 1-1/2" EMBEDMENT MIN.
INTO WALL W/ (4) #10 X 3/4" TEK
1X OR 2X
SCREW EACH SIDE INTO BEAM
PER PLAN
EDGE / END BEAM TO HOST STRUCTURE DETAIL
1X OPEN BACK
FASTEN 1X OPEN
BACK TO ALUMINUM
POST W/ #10 X 1-1/2"
TEK SCREW, 3" FROM
TOP AND BOTTOM
AND 12" O.C.
ly"Nahlo212103011 ' i
II
II
ALUMINUM COIL II
OR -
VINYL SIDING
KICKPLATE
ALUMINUM COIL OR
VINYL SIDING KICK
PLATE ATTACHED TO
ALUMINUM MEMBER
W/ (1) #10 X 3/4" TEK
SCREW AT 8" O.C.
UPRIGHT OR BEAM
SNAP OR SELF
MATING OR HOLLOW
n
II IF VINYL SIDING USE MIN.
11 2X2X.044" VERTICAL
11 UPRIGHTS AT 24" O.C. MAX.
II ATTACHED WITH 062" MIN.
II ® ANGLE W/ (2) #10 X 3/4"
TEK SCREW PER FLANGE,
TOP, BOTTOM AND ON EACH
SIDE OF UPRIGHT, TYPICAL.
• s-21HINNIF2121
1.54 Lai I'm1 WIN
L : •
HINGE LOCATION
_Z _Z
IL =CL j z0-
HINGE LOCATION
HINGE LOCATION
NOTES:
1. HINGES SHALL BE ATTACHED TO STRUCTURE W/ (3) #10 X 3/4"
TEK SCREW MINIMUM.
2. DOOR SHALL BE ATTACHED TO ENCLOSURE W/ (2) HINGES
MINIMUM.
3. HINGES SHALL BE ATTACHED TO DOOR WITH (3) #10 X 3/4"
TEK SCREW. FASTEN A 1"X2"X0.044" TO UPRIGHT
W/#12 X 1-1/2" TEK SCREW @ 12" O.C. AND WITHIN 3" FROM
END OF THE UPRIGHT,
noTlnW 40
0.062" MIN. ALUM. INTERNAL
OR EXTERNAL RECEIVING
CHANNEL W/ (4) #10 X 3/4"
TEK SCREWS INTO UPRIGHT
AND (2) #12 X 3/4" TEK SCREWS
EACH LEG INTO GIRT
I
2X ALUM. PER PLAN I I 1 2X ALUM. PER PLAN
- — — — — — — — — — a — — — — — — — — — —
0.062" MIN, ANGLE CLIP J 1 I ALUM. UPRIGHT
W/ (2) #12 X 3/4" TEK I I PER PLAN
SCREWS EACH LEG I 1
1 I
OPTION #1
CHAIR RAIL AND GIRT CONNECTIONS
I HEREBY CERTIFY THAT I HAVE REVIEWED
THIS PLAN AND FOUND IT TO BE 1N
COMPLIANCE WITH ASCE 7-16 AND FBC 7TH
EDITION RESIDENTILAND EXISTING
BUILDINGx1V0011 I111j/��
�LCiitC��
PROFESSIONAL ENGINEER SEAL
ENGINEER OF RECORD
David W. Smith P.E.
FLORIDA LICENSE NUMBER: 53608
Thomas L. Hanson P.E.
FLORIDA LICENSE NUMBER: 38654
Ian J. Foster P.E.
FLORIDA LICENSE NUMBER: 93654
Joel Falardeau P.E.
FLORIDA LICENSE NUMBER: 70667
Erik Stuart P.E.
FLORIDA LICENSE NUMBER: 77605
FBC Plans & Engineering
Services, Inc.
6272 Abbott Station Drive Unit 101
Zephyrhills, fl. 33542
Phone:(813)788-5314
Fax:1-(866)-824-7894
Email: erb@Ebcplans.com
Website: www.fbcplans.corn
C,O.A, - #29054
I DATE: 09/08/2022 1
I REVISION: I DATE: I
RO 4
O: # 22 i•
L6114, r::rr
PLOURDE
37350 CORNWALL DR.
ZEPHYRHILLS, FL. 33542
CK0 1710#116 e�
SUNSTATE ALUMINUM