Loading...
HomeMy WebLinkAbout22-4966Address: 6828 Shelby Lynn Way ZEPHYRHILLS, FL 33542 INSTALLATION ROOF MOUNT SOLAR PV Electrical Permit Fee Issue Date: 1III /10/2022 Building Valuation: $1 .00 Electrical Valuation: $44,692,62 Mechanical Valuation: Plumbing Valuation: Total Valuation: $44,693.62 Total Fees: $263.46 Amount Paid: $263.46 Date Paid: 10/10/2022 1:22:33PM $263.46 Nq 1" ilk V, REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. I I I I I I I Jill I �11 III I � 3 ffmmwywwmmjmm=• � EEEMBM��� Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. le," CONTk&GTO-R!f1bNA7If PEJAIT OFFICE() P ERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION 09-TET T 7. .TT, T", NTTI' M'�� 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permitting (561 ) 609-2664 Owner's Name LUIS HERRERA Owner Phone Number 6616092664 Owner's Address 6828 SHELBY LYNN WAY Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 6828 SHELBY LYNN WAY, ZEPHYRHILLS, FL 33542 LOT# 69 SUBDIVISION LINKS AT CALLISA SPRING PARCEL ID# 1 04-26-21-0260-00000-0690 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD/ALT t�.J SIGN DEMOLISH e INSTALL 8 REPAIR PROPOSED USE © SFR COMM 0 OTHER I SOLAR TYPE OF CONSTRUCTION BLOCK FRAME STEEL DESCRIPTION OF WORK INSTALLATION OF SOLAR PV SYSTEM TO ROOFTOP BUILDING SIZE SQ FOOTAGE C----� HEIGHT =BUILDING VALUATION OF TOTAL CONSTRUCTION ELECTRICAL $ - AMP SERVICE PROGRESS ENERGY W.R.E.C. =PLUMBING $ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS ROOFING SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY SIGNATURE REGISTERED Y / N FEE CURREN Y / N Address License # I CVC56948 —I ELECTRICIAN COMPANY URBAN SOLAR GROUP SIGNATURE REGISTERED Y / N FEE CURREN Y / N Address 1 12 BRO N SOUND PKWY STE F BOCA RATON, FL 33487 License # EC13005324 PLUMBER COMPANY SIGNATURE REGISTERED Y / N FEE CURREN Address License # MECHANICAL COMPANY SIGNATURE REGISTERED Y / N FEE CURREN Y / N Address License # OTHER COMPANY SIGNATURE REGISTERED Y / N FEE CURREN Y / N Address I License # I tt I I I I I I I I I I I I I I I I I I I I I l I I I I I I I I I I I I I I I I I f i RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (A/C upgrades over $7500) — Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences (PlottSurvey/Footage) Driveways -Not over Counter if on public roadways..needs ROW 813-7804020 City of Zephyrhills;'Iderrriit Application Fax-813-780-0021 Building Department NOTICE OF DEED RESTRICTIONS: The undersignted understands that this permit may be subject to'deed' restrictions" wbich may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not lioensedas required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the oviner or intended contractorare uncertain as to Mat licensing requirerrm,-his may apply forthe intended vork, they are advised to contact the Pasco County Buildin rasp ion Division —Licensing Section at 727-847- 800-9. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the 'contractor Black' of this application for which they %Mll be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privis in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES, The undersigned under -stands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildinggs, or expansion of existing buildings, as specified in Pasco County Ordinance number 819-07 and 90-07, as amended. The urn dersigined also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Irnpact Fees and Resource Recovery Fees must be paid prior to receiving a 'certificate of occupancy' or firm, I power release. If the project does not involve a certif irate of occupancy or final power rek,,ase, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Watep'Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as arrended): if valuation of work is $2,5W.00 or rnore, I certify that 1, the applicant, have been provided with a copy of the "Florkla Construction Lien Law—Homeavinet's Protection Guide' prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone ofther than the "ovirrer, I certify that I have obtained a copy of the above descrbed document and promise in good faith to deliver it to I he 'owner` prior to commencernerut. CO NTRACTOR'S/OWN E R'S AF F IDAVIT: I certify that all the info rn-sa tion in this application is accurate and that all work will I be done in cornp, In rice with all applicable la%vs regulating consiny-tion, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulatioRs in thejurisdicLion. I also certify that I understand that the regulations of other government agencies may apply to the intended work, arrd that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Watern' Vest ewtiter Treatment. Southwest Florida Water Managernient District -Wells, Cypress Bayheads, Wetland Areas., Altering Watercourses. - Army Corps of Engineers -Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit - Wells, Wastevmter Treatment, Septic Tanks. - US Environmental Protection Agency -Asbestos abatement. - Federal Aviation Authority -Runways. I understand that the following restrictions apply to file use of fill: Use of fill is not allowed in Flood Zone "W unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "'A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stemwall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to comn-kencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, %-tells, pools, airconditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be license to proceed, with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official frorn thereafter requiring a correction of errors in plans, construction or violations of any codes. Every period issued shall become invalid unless the %vork authorized by such permit is comrnenced within six ninths of permit issuance, or if work authorized by the permit is suspended or abandoned fore period of six (6) months after the time the work is commenced. An extension may be recluestedin writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) Consecutive days, the job is considered abandoned. 11`0 10; 1111104011111 0.4 14 A 0 1 WN Z W�TJ ap Mv 901M OWNERORA,GENT CONTOR and sworn to (or affirmeed) before me this _ 'kafore this by b Whoisiampersonally krKvn to me or awhave prou"aQ07allntor I as identification. as identification. 11131311� Go mini ss io n No. I � k Wie—o-f Woffi- f j T�' -6-r-stifiT Corn Fission No. �_=2JJRU3C M-La- 14r N 600 56.1 � �;Rw 'Ap&fin ee Notary Public DocuSign Envelope ID: ABE6D53E-8COE-448C-9B26-BC14BOB2215A UrbanSolar �® w We Faring energy to life." CONTRACT FOR SOLAR PV SYSTEM ACCORDING TO FLORIDA'S CONSTRUCTION LIEN LAW (SECTIONS U 3Z, FLORIDA STATUTES), THOSE WHO WORK ON YOUR PROPERTY OR PROVIDE MATERIALS AND SERVICES AND ARE NOT PAID IN FULL HAVE A RIGHT TO ENFORCE THEIR CLAIM FOR PAYMENT AGAINST YOUR PROPERTY. THIS CLAIM IS KNOWN AS A CONSTRUCTION LIEN. IF YOUR CONTRACTOR OR A SUBCONTRACTOR FAILS TO PAY SUBCONTRACTORS, SUB -SUBCONTRACTORS, OR MATERIAL SUPPLIERS, THOSE PEOPLE WHO ARE OWED MONEY MAY LOOK TO YOUR PROPERTY FOR PAYMENT, EVEN IF YOU HAVE ALREADY PAID YOUR CONTRACTOR IN FULL. IF YOU FAIL TO PAY YOUR CONTRACTOR, YOUR CONTRACTOR MAY ALSO HAVE A LIEN ON YOUR PROPERTY. THIS MEANS IF A LIEN IS FILED YOUR PROPERTY COULD BE SOLD AGAINST YOUR WILL TO PAY FOR LABOR, MATERIALS, OR OTHER SERVICES THAT YOUR CONTRACTOR OR A SUBCONTRACTOR MAY HAVE FAILED TO PAY. TO PROTECT YOURSELF, YOU SHOULD STIPULATE IN THIS CONTRACT THAT BEFORE ANY PAYMENT IS MADE, YOUR CONTRACTOR IS REQUIRED TO PROVIDE YOU WITH A WRITTEN RELEASE OF LIEN FROM ANY PERSON OR COMPANY THAT HAS PROVIDED TO YOU A "NOTICE TO OWNER." FLORIDA'S CONSTRUCTION LIEN LAW IS COMPLEX, AND IT IS RECOMMENDED THAT YOU CONSULT AN ATTORNEY. TODAY'S DATE: 8/23/2022 Client Information Client Name: ui s errera HOA Name: Street Address: 6828 Shelby Lynn way HOA Phone: city, State, Zi Zephyrhi l l s FL 33542 HOA Address: Phone: (786) 372-2167 Email: ui sao o ina� . cwr Referred By: Photovoltaic PV System Details Total Investment Amount: Panel Quantity: Total Watts: Panel Manufacturer: Proposed Annual kWh Production: sonali 15082 24 10,560.00 Panel Model: SS-M-440W Reviewed By: Claudia Trujillo Inverter: 24 17PLUS-72-2-US Q BUYER'S RIGHT TO CANCEL CLIENT acknowledges that he/she has read and received a copy of this contract, including Terms & Conditions contained, attached, or on the reverse side which are incorporated herein. All work on the above -mentioned property herein will be performed in a timely and professional manner. Buyer/client may cancel this contract without any penalty or obligation within three (3) business days from the above date by providing written notice by US Certified Mail, Return Receipt Requested to Urban Solar Inc. This cancellation must be clear in intent, written in English and postmarked before midnight of the third business day after you sign this contract. For the purposes of this Contract, a "Business Day" shall include Monday through Saturday but shall not include Sundays or any legal holiday on which the Postal Service does not deliver. This contract when signed represents the entire contract between buyer and seller, is accepted as satisfied, and is binding when accepted by Urban Solar, Inc. If the right to cancel period expires, the seller's contract may not be cancelled by the homeowner or applicant. CustomerinitiaY: L—� Client's Annual kWh Usage 12669 Pace: NA Pace Estimated Monthly Payment: NA Finance Details Conventional: Dividend 44692.62 Conventional Estimated Monthly Payment:118 . 43 171.4 Cash Purchase Payment 1 (25%) - Due upon execution of this agreement. N/A Payment 2 (50%) - Prior to first day of construction. N/A Payment 3 (25%) - On final Day of construction. N/A Application ID: Customer Initial: o E Urban Solar / 990 S Rogers Circle, Suite 4, Boca Raton, FL 33487 j 888-38-SOLAR FL Licenses: CVC56948, EC13005324 DocuSign Envelope ID: ABE6D53E-8COE-448C-9B26-BCI4BOB2215A ®� We brim enemy to life." X Click here to enroll in our Express Engineering option. We will not contact you for solar panel layout changes during the engineering process unless the production of your system is negatively affected by 500 kWh's or more. ' n� Click here if there are energy efficiency products associated with this agreement. Urban Solar does not guarantee any savings X dollar amount or kilowatt hour amount for any products such as pool pumps, water heater timers, hybrid heat pump water os heaters, nest thermostats, or any product other than solar PV panels. t Click here if there are trees on the property that could potentially shade some or all of the solar panels. The client shall be X responsible for maintaining trees. Urban Solar is not responsible for solar panel production losses due to shading. } *An 'Y' above along with client initials indicates agreement/acknowledgement Additional Comments and (Votes: Nest Thermostat, Miscellaneous, 100% Production Guarantee, cell card (IQ7PLUS) 25 years roof penetration warrant of the lifetime do the roof, whichever is less The above comments or notes section is subject to company approval. No oral representations shall be honored by Urban Solar as a part of this contract unless in writing. All other terms and conditions can be found below starting on page 3. By Signing below, you agree to all terms and conditions and you certify that you are the homeowner and/or qualified decision maker of the above referenced project. DocUSigned by: Accepted By: Name: 28E8819CDECF405... Accepted By: Name: Signed by: Docu Urban Solar: A. Name: --2F285251D2E4428... -- oed by: Urban Solar: rZZ Name: 0047B304CMMC9... Luis herrera Claudia Trujillo Harold Garrido Date: 8/23/2022 Date: Date: 8/23/2022 Date: 8/23/2022 Urban Solar l 990 S Rogers Circle, Suite 4, Boca Raton, FL 33487 l 888-38-SOLAR FL Licenses: CVC56948, EC13005324 '11*00IM1,41 . - � M. MM 0-01 al`TgR R9gQj3QINP:RETURN jM Urban Sofa, Group 1225 Broken Sound Pkwy NW Suite F Boca Raton, FL 33487 PERMIT NUMBER-, The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in " Notice of Commencement, 1, DESCRIPTION OF PROPERTY (Legat description ofthe property& street addrcsS, ifavailable) TAx FOLIO No.: 04-26-21-0260-00000-0690 SUBDIVISION LINKS AT CALUSA SPRINGS BLOCK TRACT LOT69 111.00—UNIT LINKS AT CALUSA SPRINGS PB 81 PG 074 LOT 69 6828 SHELBY LYNN WAY ZEPHYRHILLS, FL 33542 2. GENERAL DESCRIPTION OF IMPROVEMENT' INSTALLATION OF SOLAR PV SYSTEM TO ROOF TOP 3, OWNER INFORMATION OR LESSEE INFORAIATION IF THE LESSEE CONTRACTED FOR THE IMPROVENIENT. a~ Name and address: REYES LUIS GUILLERMO HERRERA 6828 SHELBY LYNN WAY, ZEPHYRHILLS, FL 33542 b. Interest in property: ywrmr - c, Name and address of fee simple titleholder (if dWomm from Ouncr listed above). 4, a. colriTtAcrows NAME', Urban Solar Group Conlractor'saddrass: 1225 Broken Sound Plivot NW. Ste F. Boca Raton, FL 33487 b. Ph. ..b, 6�1-609-26641 5. SURE'" (if applicable a copy orate payment bond isallached): a. Name and address: b. Phone number. 6. IL LENDFR'SM&MR: Lender's address, c- Amount of bond: S T Persons within the Slate of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13 (1) (a) 7., Florida Stalutesi a. Name and address: b. Phone numbers ordesignmcd Wsc,m: S. a. In addition to himself or herself, Owner designates of_ toreceive a copy of the Lienor's Notice as provided in Section 713.13 (1) (b), Florida Statutes. b. Phone number ofpersa, or entity designated by Owner: 9. Expiration date of'notice of commencement (the expiration date will be I year from the dale of recording unless a different date is specifiod);__ 20 (Signature of0rivner or Lessee, or Owners or Lessee's Authorized Offlcet,/D�*"toi-/Partnei-/'i%tannger) State of n6y�� County REYES LUIS GUILLERMO HERRERA (Print Name and Provide Signatory's Title/Office) el Cj-- The foregoing instrument was adnowledged before me this 3 day ofi 20 by REYES LUIS GUILLERMO HERRERA as Owner (name of person) for (name of party on behalf of whom instrument was exec Personally Known l or Produced ldcritification-)6— VICTORIAWAGNER WCOMMMSION#H A .44 EXPIRES. 616, 2026 (type ofatttliority> ... e.g. officer, trustee, attorney in Fact) by means of_ physical presence or_ online notarization. Type of Identification Produced (Signatureflad'Not A�� �bt (Print, Type, or Stamp Co`Kmissioi ed Name of Notary Public) Rev. to-15-12 E2 Solar pmfersinov/ s"n/ooe^oo cons"m"o �~~ Urban Solar Group, INC QQOSouth Rogers Circle, #4 Boca Raton, FL33487 License #CVC56948 RE: Engineering Services Herrera Residence 0828Shelby Lynn Way, Zophyrhi||a.FL 0.S0kYVSystem Solo Job #2S4O298 TuWhom |t May Concern, 814E1475N Lehi, UT 84043 m admin@luoenteng.co We have reviewed the following information regarding the solar panel installation for this project. Alterations to these documents or plans shall not be made without direct written consent of the Engineer of Record. The following structural design regarding the proposed alterations have been prepared from these assumptions, The verification ofthe field observations isthe responsibility nfthe contractor. Prior tocommencement nf work, the contractor shall verify the framing sizes, spacings, and spans noted in the sealed plans, calculations, and/or certification letter and notify the Engineer of Record of any discrepancies. Roof Finish RoofUndedaymort Roof Profile Roof Structural System Truss Top Chord/Setup Chord/Rafter Wood Grade Tmso/Ra#erSpauing Roof Slope Max Top Chord/Rafter Span Bearing Wall Type Foundation Stories Roof Asphalt Shingle OSB Hip Gable Metal Plate Trusses 2x4/Double Fink Southern Pine #2urbetter 24" o.o. 23deg 7.U5ft ConWLt-FmmaConsk Permanent Concrete Two Code 2020FBC.7thEdV\SCE716> Risk Category U Roof Live Load 2Opsf(0mfmdpane|u) Occupancy Class R-3 Ground Snow Load Opof Roof Dead Load 0.5paf U|tWind Speed 140mph PVDead Load: 3 psf Exposure Category C Total Dead Load : 0.5paf C. Summary of Existing Structure Results Roof After review of the field observations and based on our calculations and in accordance with the applicable building codes and current industry standards, the existing roof structure supporting the proposed alterations consisting ofthe solar array has been determined tobe: - Adaquate to support the additional imposed loads. No structural upgrades are required. 1 So|orpana|oohaUbedeoigned.mounted.andinstaUodinacourdanmyvvithUhemmstnaoent''|nmridga &4onuay'.which can befound onthe |mnhdgewebnbeNftp:0mnhdge.conV. 2. Manufacturer's Panel Bracket Connection to Roof Chord/Rafter Member. Faotemer: (1)5/1O^Lag Screw per Bracket NDSVVithdmw|Value: 307lbn/inoh Min. Thread Length and Pentration Depth : 2.5" 3. Considering the existing roofs slope, size, spacing, condition, and calculated loads, the panel bracket supports shall beplaced nogreater than 48in. m±. 4. Panel supports connections shall be staggered to distribute load to adjacent trusses. E. Overall Summary Based on the information supplied to us at the time of this report, on the evaluation of the existing structure, and solar array panel bracket connection, it is our opinion that the roof system will adequately support the additional loads imposed bythe solar array. This evaluation conforms 0o2O2UF8C.7thEdand current industry standards. Should you have any questions regarding this letter or if you require further information, do not hesitate to contact me. Limits ofScope of Work andUmbldy The existing structure is assumed to have been designed and constructed following appropriate codes at the time oferection and assumed tuhave appropriated permits. The calculations performed are only for the roof framing supporting the solar array installation referenced in the stamped plans and were completed according togenerally recognized structural analysis standards and procedures, professional enUinoehng.enddeuign experience opinions and judgements. Existing deficiencies which are unknown orwere not observed during the time the site observation are not included inthis scope ofwork. All solar panel modules, racking, and mounting equipment shall be designed and installed per the manufacturer's approved installation specifications. The Engineer of Record and the engineering consulting firm assume no responsibility for misuse or improper installation. This analysis ionot stamped for water leakage. Framing was determined oninformation in provided plans and/or photos, along with engineering judgement. Prior 0ucommencement ofwork, the contractor shall verify the framing sizes, spacings, and spans noted in the stamped plans, calculations, and/or certification letter and notify the Engineer of Record of any discrepancies prior to starting construction. If during solar panel installation, the roof framing members appear unstable or deflect non -uniformly, our office should benotified before proceeding with the installation. The contactor shall also verify that there are no damage/deficiencies (i.e., dry rot, water damage, termite damage, framing member/connection damage, etc.) to framing that was not addressed in the stamped plans, calculations, and/or certification letter and notify the Engineer ofRecord ofany concerns prior tostarting construction. Page 2 of 2 Herrera Residence •.,ELILei 11111:11141 ARTICLEf. INSTALLATION OF SOLAR PHOTOVOLTAIC SYSTEM SHALL BE IN ACCORDANCE WITH NEC ARTICLE 690, AND ALL OTHER APPLICABLE NEC CODES WHERE NOTED OR EXISTING 2. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC :1. ALL WIRES, INCLUDING THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE IN ACCORDANCE WITH NEC ARTICLE 250 THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE; THIS SYSTEM IS UTILITY INTERACTIVE PER UL 1741 AND DOES NOT INCLUDE STORAGE BATTERIES OR OTHER ALTERNATIVE STORAGE SOURCES PHOTOVOLTAIC (PV) SYSTEM SPECIFIC TI � ,, a exig .l S' pi tiy9 EQUIPMENT: S AC System Size: 6.96 kW AC �' DC SYSTEM SIZE: 1056 kW DC (24) Sonal SS-M-440 PV Modules (24) Enphase IQ7PLUS-72-2-US Inverter(s) RACKING: Quick Mount L-Mount (QMLM) - 48" O.C. ��� � '9' r) p; ,`J, N� t '1 r4 Iffil 1.114 ScIlIIIII' 10111 k1l! • ! UrbanSola ]RBA\ SOLAR f11 1! t90 SOUTH ROGERS CIRCLE, BOCA 1 ! • 33487 License #CVC56948 Luis Herrera 6828 Shelby Lynn Way Zephyrhills, FL 33542 AC System Size: 6.96 kW AC DC System Size: 10.56 kW DC Lat, 28.2565506 Long,-82.2078742 (24) Sonali SS-M-440 PV Modules (24)EnphaselQ7PLUS-72-2-US Inverter(s) Duke Energy ROOF ATTACHMENTS 0, MOUNTING DETAIL PV05 LINE DIAGRAM • i, ELECTRICAL CALCS LABELS • ! 8 • •. PV,!. SITE PHOTOS F7777DRAWN BY Sol®CAD DATE: September 6, 2022 COVER PAGE - PV01 -441-311 Fj I ARRAY DETAILS: MOUNTING PLANE: AZIMUTH: TILT: MP1 1820 230 MP2 92o 23' MP3 20 23o STRING 1: 13 MODULES STRING 2: 11 MODULES EQUIPMENT LEGEND: UTILITY METER , [ VISIBLEAC DISCONNECTLOCKABLE, LABELED ,Nv INVERTER [suB] SUB PANEL [SD] SERVICE DISCONNECT El PV MODULES FIRE ACCESS PATHWAY (TTYP) MSP MAIN SERVICE PANEL LJ METORER UTILISOCKETTY PV METER) (F D COMBINER BOX E LOAD CENTER H BATTERY(JES) E I JUNCTION BOX PROPERTY LINE Mm '010 0 as 4's a 00 80 `UrbanSola URBAN SOLAR GROUP, INC 990 SOUTH ROGERS CIRCLE, BOCA RATON, FL 33487 License #CVC56948 Luis Herrera 6828 Shelby Lynn Way Zephyrhills, FL 33542 AC System Size: 6.96 kW AC DC System Size: 10.56 kW DC Lat, 28.2565506 Long, -82.2078742 (24) Sonali SS-M-440 PV Modules (24) Enphase IQ7PLUS-72-2-US inverter(s) IDuke Energy I VISIBLE, LOCKABLE, DRAWN BY: SoIoCAD LABELED AC DISCONNECT DATE: LOCATED WITHIN 10' September 6, 2022 OF UTILITY METER SITE PLAN - PV02 N I I N E, 441-311 SITE INFORMATION Luis Herrera 6828 Shelby Lynn Way Zephyrhills, FL 33542 AC System Size: 6.96 kW AC DC System Size: 10.56 kW DC Lat, 28.2565506 Long, -82.2078742 (24) Sonali SS-M-440 PV Modules (24) Enphase IQ7PLUS-72-2-US Inverter(s) I- Duke Energy EQUIPMENT INFORMATION: ROOF INFO: PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA: RAIL MANUFACTURER: IronRidge ROOF TYPE: Asphalt Shingle PV MODULE COUNT: 24 RAIL PART NUMBER: XR-10 ROOF FRAMING: Manufactured Truss ARRAY AREA: MODULE COUNT * 23.31 ft2 = 559.44 ATTACHMENTS Quick Mount L-Mount (QMLM) RAFTER/TOP CHORD SIZE: 2x4 ROOF AREA: 1911 ft, ATTACHMENT QTY: 68 RAFTER/TOP CHORD SPACING: 24" PERCENT OF ROOF COVERED: 29% SPLICE CITY: 0 ATTACHMENT SPACING: 48" ARRAY WEIGHT: MODULE COUNT * 53 lbs = 1272 lbs MIDCLAMP QTY: 30 POINT LOAD: ARRAY LBS/ATTACHMENTS = 18.71 ENDCLAMP QTY: 36 DISTRIBUTED LOAD: (lbs/ft') (ARRAY) WEIGHT/AREA = 2.27 Ibs/i DRAWN BY: SoloCAD DATE: September 6, 2022 ROOF ATTACHMENTS - PV03 0011104F.3all MR 0 END DCLAMP DETAILS� _ PV MODULE RAIL 2 MID CLAMP DETAILS®� WMK"o um QUICK MOUNT L-MOUNT 5/16" STAINLESS STEEL LAG -BOLT WITH 2-1/2" MIN. EMBEDMENT AND FLAT WASHER L r PETMOUNTING AND FLASHING AIL, 0 4 a UrbanSola V-8" MAX. k MAX." CONTRACTOR INFORMATION: FRONT VIEW (E) RAFTEP470P CHORDS URBAN SOLAR GROUP, INC 990 SOUTH ROGERS CIRCLE, #4 BOCA RATON, FL 33487 License #CVC56948 QUICK MOUNT L-MOUNT BENZ= 61FRI&TIMM 2'-8" MIN - 3'-10" MAX C EQUIPMENT INFORMATION: ROOF INFO: PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA: RAIL MANUFACTURER: IronRidge ROOF TYPE: Asphalt Shingle PV MODULE COUNT: 24 RAIL PART NUMBER: XR-10 ROOF FRAMING: Manufactured Truss ARRAY AREA: MODULE COUNT * 23.31 ft2 = 559.44 ATTACHMENTS Quick Mount L-Mount (QMLM) RAFTER/TOP CHORD SIZE: 2x4 ROOF AREA: 1911 ft2 ATTACHMENT QTY: 68 RAFTER/TOP CHORD SPACING: 24" PERCENT OF ROOF COVERED: 29% SPLICE QTY: 0 ATTACHMENT SPACING: r 48" ARRAY WEIGHT: MODULE COUNT * 53 lbs = 1272 lbs M I DCLAMP QTY: 30 POINT LOAD: ARRAY LBS/ATTACHMENTS = 18.71 ENDCLAMP QTY: 36 DISTRIBUTED LOAD: (lbs/ft') (ARRAY) WEIGHT/AREA = 2.27 IbS/ft2 0. kk Luis Herrera 6828 Shelby Lynn Way Zephyrhills, FL 33542 AC System Size: 6.96 kW AC DC System Size: 10.56 kW DC Lat, 28.2565506 Long, -82.2078742 (24) Sonah SS-M-440 PV Modules (24) Enphase IQ7PLUS-72-2-US Inverter(s) I- Duke Energy Na, 9 7. OF % DRAWN BY: SoIoCAD DATE: September 6, 2022 MOUNTING DETAIL - PV04 Sonali SS-M-440 Specs POWER MAX (PMAX): 440W OPEN CIRCUIT VOLTAGE (VOC): 41.2V MAX POWER -POINT CURRENT (IMP): 12.74A MAX POWER -POINT VOLTAGE (VMP): 34.5V SHORT CIRCUIT CURRENT (I5C): 13.54A SERIES FUSE RATING: 20 A STRING (1): 15.730 A AC 13 MODULES STRING (2): 13.310 A AC 11 MODULES EnphaselQ7PLUS-72-2-US Specs MAX INPUT VOLTAGE: 60 V MAX DC SHORT CIRCUIT CURRENT: 15 A MAXIMUM OUTPUT POWER: 290 W MAXIMUM OUTPUT CURRENT: 1.21 A M. OUTPUT VOLTAGE: 240 V MAX UNITS PER 20A CIRCUIT: 13 1-Phase, 60 HZ, UL 1741 Listed Equipment Schedule TYPE: CITY: DESCRIPTION: RATING: MODULES: (24) Sonali SS-M-440 440 W INVERTERS: (24) EnphaselQ7PLUS-72-2-US 290 W AC DISCONNECTS: (1) PV AC Disconnect, 240V, 2-Pole 60 A Conduit & Conductor Schedule TAG CITY WIRE GAUGE DESCRIPTION CONDUITSIZE (2) 12-2 PV-WIRE, USE-2 COPPER - (L1, L2) 1 (1) 10 AWG THWN-2COPPER -(GROUND) N/A -FREE AIR (2) 10 AWG THHN/THWN-2 COPPER- (Ll, L2) 2 (1) 10 AWG THWN-2COPPER -(GROUND) 1" PVC (4) 10 AWG THHN/THWN-2 (1-1, L2) 3 (1) 10 AWG THWN-2 COPPER -(GROUND) 1" PVC (3) 8 AWG THWN-2 COPPER - (L1, L2, NEUTRAL) 4 (1) 10 AWG THWN-2 COPPER -(GROUND) 1" PVC (E) GROUNDING (E) UTILITY METER ELECTRODE VISIBLE, LOCKABLE, LABELED AC DISCONNECT LOCATED WITHIN 10, OF UrbanSoLa egego 41 URBAN INC r i O C A • 33487 License • . 4 8 Luis Herrera 6828 Shelby Lynn Way Zephyrhills, FL 33542 AC System Size: 6.96 kW AC DC System Size: 10.56 kW DC Lat, 28.2565506 Long,-82.2078742 (24) Sonali SS-M-440 PV Modules (24) Enphase IQ7PLUS-72-2-US Inverter(s) L_ Duke Energy _j F77DRAWN BY: SoIoCAD DATE: September 6, 2022 LINE DIAGRAM - PV05 STRING CALCULATIONS MAX AC CURRENT: 15.73A 13.31A MICRO INVERTERS IN SERIES 13 11 NOMINAL STRING VOLTAGE: 240V 240V MAX AC OUTPUT POWER 3770W 319OW ARRAY DC POWER: 10560W TOTAL MAX AC CURRENT: 29.04A NUMBER OF CURRENT CARRYING CONDUCTORS PERCENT OF VALUES SYSTEM OCPD CALCULATIONS # OF INVERTERS: 24 MAX OUTPUT CURRENT: 1.21A I# OF INVERTERS) X (MAX OUTPUT CURRENT) X 125% <= OCPD RATING MAIN BUSBAR RATING: 200A MAIN DISCONNECT RATING: 200A (MAIN BUS RATING X 120%) - MAIN DISCONNECT RATING >= OCPD RATING Conduit & Conductor Schedule TAG CITY WIRE GAUGE DESCRIPTION CONDUIT SIZE CONDUCTOR RATING CONDUCTOR TEMP. RATE AMBIENTTEMP TEMP. DERATE # OF CONDUCTORS CONDUCTOR RATING CONDUIT FILL I. PVINVERTER BUNGROUNDED, TRANSFORMER -LESS TYPE. 2. DC GEC AND AC EGC TO BE SPLICED TO EXISTING ELECTRODE 3.ANY EXISTING WIRING INVOLVED WITH PVSYSTEM CONNECTION THAT ISFOUND T08E INADEQUATE PER CODE SHALL BECORRECTED PRIOR TOFINAL INSPECTION. 4.JUNCTION BOX QUANTITIES, AND PLACEMENT SUBJECT TDCHANGE |NTHE FIELD JUNCTION BOXES DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE TYPE TRANSITIONS. 5�ACDISCONNECT NOTED |NEQUIPMENT SCHEDULE OPTIONAL |FOTHER AIDISCONNECTING MEANS |SLOCATED WITHIN 1O'OFSERVICE DISCONNECT. l. INTERCONNECTION SIZING, LIMITATIONS AND COMPLIANCE DETERMINED IN ACCORDANCE WITH [NEC 7O5.l2]. Z.GROUND FAULT PROTECTION |NACCORDANCE WITH [NEC Z15.8]'[NEC 230.95]AND [NEC 69O.411 I ALL EQU|PMENTTD8ERATED FOR BACKFEE0NG. 4. PV BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE BUSBAR RELATIVE TO THE MAIN BREAKER. 1. DISCONNECTING SWITCHES SHALL 8EWIRED SUCH THAT WHEN THE SWITCH |SOPENED THE CONDUCTORS REMA|N|NGUVEAREC0NNECTEDTOTHETERW1|NAL5yMARKED^L|N[8DE^(TYP|CALLYTHEUPPERTERW1|NALS) 2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A V|8BLE'BREAKSVVOTH Luis Herrera 68z8Shelby Lynn Way oephy,hU|s,p/sss42 xcSystem Size: s.9sNwx[ ocSystem Size: zn.s6mwo[ Lat28.25assU8 Long,eo.2078742 (o^) sonaUss-rw-44o Pvmodukes (24)snpha,e|O7puuS-/2-2-US Duke Energy I DRAWN BY: SoloCAD TERMINALS ON r IN THE OPEl `• • DEVICE,MAIN SUPPLY OVERCURRENT • r AMPACITY OF i i a t:. LABEL 1 FOR PV DISCONNECTING MEANS WHERE THE LINE AND LOAD TERMINALS MAY BE ENERGIZED IN THE OPEN POSITION. [NEC 690.13(B)] LABEL 2 PLACED ADJACENT TO THE BACK -FED BREAKER FROM THE INVERTER IF TIE IN CONSISTS OF LOAD SIDE CONNECTION TO BUSBAR. [NEC 705.12(B)(2)(3)(c)I LABEL 3 PLACED ADJACENT TO THE BACK -FED BREAKER FROM THE INVERTER IF TIE IN CONSISTS OF LOAD I VTE OUTPUT C ECIO SIDE CONNECTION TO BUSBAR. [NEC 70S.12(13)(2)(3)(b)] 90 ki• " •IT i DEVICE LABEL 4 EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR OR CONDUCTOR SUPPLIED FROM MULTIPLE SOURCES SHALL BE MARKED TO INDICATE THE PRESENCE OF ALL SOURCES [NEC 705.12(B)(3)] LABELS AT POINT OF INTERCONNECTION, MARKED AT AC DISCONNECTING MEANS. [NEC 690.541 LABELING NOTES: 1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. 2. LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRIC CODE, OSHA STANDARD 19010.145, ANSI Z535. 3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [NEC 110.21(B)(3)] 5. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, AND PERMANENTLY AFFIXED [NEC 690.31(G)] TURN RAPID SHUTDOWN SWICH TO THE "OFF' POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY SOLAR 5LV.,V C. aV PANTLS TURN RAPID SHUTDOWN SWITCH TO THE "OFF' 1 POSITION TO SHUT DOWN I _ CONDUCTORS OUTSIDE THE ARRAY. CONDUCTORS WITHIN THE ARRAY REMAIN ENERGIZED IN SUNLIGHT I L6 JUNCTION BOX O LABEL 6 AT DIRECT -CURRENT EXPOSED RACEWAYS, CABLE TRAYS, COVERS AND ENCLOSURES OF JUNCTION BOXES, AND OTHER WIRING METHODS; SPACED AT MAXIMUM LOFT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS. [NEC 690.31(G)(3&4)] LABEL 7 FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [NEC 690.56(C)(1)(a)] LABEL 8 FOR PV SYSTEMS THAT ONLY SHUT DOWN CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [NEC 690.56(C)(1)(b)] LABEL 9 SIGN LOCATED AT RAPID SHUT DOWN DISCONNECT SWITCH [NEC 690.56(C)(3)]. PV COMBINER SUBPANEL - IF USED TO COMBINE PV OUTPUT CIRCUITS OR INVERTER O AC D�ISCONNNEECT �. / `� EXISTING SUB PANEL (ONLY IF WHERE POINT OF INTERCONNECTION IS MADE) MAIN SERVICE PANEL 0 O OR 19 no so " UrbanSola Do fa 0 fa 19's a URBAN SOLAR GROUP, ,)90 SOUTHrO, RS CIRCLE, .. BOCA RATON, FL 33487 License #CVC56948 Luis Herrera 6828 Shelby Lynn Way Zephyrhills, FL 33542 AC System Size: 6.96 kW AC DC System Size: 10.56 kW DC Lat, 28.2565506 Long,-82.2078742 (24) Sonali SS-M-440 PV Modules (24)EnphaselQ7PLUS-72-2-US Inverter(s) Duke Energy (ONLY IF PV (ONLY IF PV INTERCONNECTION INTERCONNECTION DRAWN BY: SoloCAD CONSISTS OF LOAD CONSISTS OF LOAD SIDE BREAKER) SIDE BREAKER) L-1 DATE: September 6, 2022 ** ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENATION OF ------- EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED MAY VERY DEPENDING ON TYPE OF LABELS - PV07 INTERCONNECTION METHOD AND LOCATION PRESENTED ELECTRICAL DIAGRAM PAGE. ** DIRECTORY PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM. (ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS OUTLINED WITHIN: NEC 690.56(B)&(C), [NEC 705.101) a a qp ge a 0 D 0*8 UrbanSola o URBAN SOLAR GROUP, INC 990 SOUTH ROGERS CIRCLE, #4 BOCA RATON, FL 33487 License #CVC56948 wholin Luis Herrera 6828 Shelby Lynn Way Zephyrhills, FL 33542 AC System Size: 6.96 kW AC DC System Size: 10.56 kW DC Lat, 28.2565506 Long, -82.2078742 (24) Sonali SS-M-440 PV Modules (24) Enphase IQ7PLUS-72-2-US Inverter(s) I- Duke Energy DRAWN BY: SoloCAD DATE: September 6, 2022 PLACARD - PV08 a 00 O's ge UrbanSoLa ,age gan a 11[gaulf-alm URBAN SOLAR GROUP, INC 990 SOUTH ROGERS CIRCLE, #4 BOCA RATON, FL 33487 License #CVC56948 N161HIMI1. "S Luis Herrera 6828 Shelby Lynn Way Zephyrhills, FL 33542 AC System Size: 6.96 kW AC DC System Size: 10.56 kW DC Lat, 28.2565506 Long, -82.2078742 (24) Sonali SS-M-440 PV Modules (24) Enphase IQ7PLUS-72-2-US inverter(s) I- Duke Energy I DRAWN BY: SoloCAD DATE: September 6, 2022 SITE PHOTOS - PV09 UNA SS-M-440 to 460 Series' Quality Product All Manufactured modules are tested 100% by EL (Electroluminescence) during the Production Process & Free from micro cracks. Our high-performance modules are highly efficient, reliable and provide optimal output. The company manufactures solar modules in compliance with global standard including MNRE, IEC 61215, 61730-1, 61730-2, 61701, U L 1703, U L 61730, ISO 9001:2008 & ISO 14001:2004 & 18001:2007. High Efficiency . High Module efficiency is obtaining top performance even in diffused light conditions. We are leaders in providing our customers with maximum sunlight conversion. Application Possibilities Residential and Commercial rooftops, Car ports, Solar Farming, Balconies, Awnings, Street lights, Fences, and Canopies. Our Team We have a team of qualified experts and engineers making sure that modules produce maximum power. We pride ourselves in caring for each individual customer needs with detailed attention. Our end goal is to give a highly efficient product with exceptional customer service. Guarantee Our product is durable and has 25 years performance warranty. Integrated manufacturing of cells & modules in production line guarantees optimum performance. US OFFICE: Sonali Energees USA LLC Ill Charlotte Place Suite 101A Englewood Cliffs, NJ 07632 Office Tel: 201-568-1424 info@sonalisolar.com www,sonalisolar.com SS01HCLSDE-5S01HUSDE SUNA SS-M-440 to 460 Serlles::�, Electric Performance Parameter Model SS-M-440 SS-M-445 SS-M-450 SS-M-455 SS-M-460 Nominal Maximum Power (Pmax/W) 440 445 450 455 460 Optimum Operating Voltage (Vmp/V) 34.5 34.8 35.0 35.2 35.5 Optimum Operating Current (Imp/A) 1234 12.8 12.86 12.91 12.97 Open Circuit Voltage (Voc/V) 41.2 41.4 41.15 41.8 42.0 Short Circuit Current (isc/A) 13.54 13.6 13.66 13.72 13.78 Measurement Power Tolerance on Power 0 / +% Normal Operating cell Temperature (NOCT) of irradiance of 800W/m2, 43± 2* C Under Standard Test Conditions (STC) of irradiance of 1000W/m2 Spectrum AM 1.5 and cell temperature of 25 *C Maximum System Voltage: 1500v IEC/UL Mechanical Parameter Temperature Coefficient 1910 X 1134 X 35 mm Module Dimensions Coefficient of Current +0.05% /*C 75.2 X 44.65 X 1.38 inch Weight 24 kgs / 52.91 lbs Coefficient of Voltage -0.29% /-C Cell Size (Monocrystalline) 182x91 mm / 6.53x3.27 in Coefficient of Power -0.37% /-C No Of Cell 120 (6 X 20) Tested Operating Conditions Junction Box Solar Cable Connectors Glass (Tempered & Low Iron) Encapsulate Back Cover (Black Color) Frame (Black Color) IP68, 3 Bypass diodes N 400mm (15.75 inch) P 300mm (11.81inch) length with 4mm' IVIC4 compatible 3.2mm (0.125in) ARC EVA Composite Sheet Anodized Aluminum Alloy Temperature Cycling Range -40'C to 85'C Humidity Freeze, Damp Heat Product Warranty Product Warranty Performance Warranty 85% RH 12 Years First 10 Years up to 90%, next 15 years up to 80% 1134 — -------- - ------ 1084 I-V Curve at Different Temperature T_­ 76 . .. ........ "'AL,,W 3 40 I-V/P-V Curve at Different Irradiation m. Tl 35 . .... . . .. 2 Ti www.sonalisolar.com ,)a'a Enphase IN"Alicroinverters A.,S If=—" Yfil Ph C-3 seo 1 7 a n d -7 + Mi c, r o i n v e r t e r s The high-powered smart grid -ready Enphase IQ 7 Micro' and ErIphase IQ 7+ Nlicro' dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ EnVoyT1 , Enphase IQ BatteryTM, and the Enphase EnlightenTl monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, enabling Enphase to provide an industry -leading warranty of up to 25 years. Easy to Install Lightweight and simple Faster installation with improved, lighter two -wire cabling Built-in rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable Optimized for high powered 60-cell/120 half cell and 72- cell/144 half -cell* modules More than a million hours of testing Class 11 double -insulated enclosure UL listed Smart Grid Ready Complies with advanced grid support, voltage and frequency ride -through requirements Remotely updates to respond to changing grid requirements Configurable for varying grid profiles Meets CA Rule 21 (UL 1741 -SA) * The Q 7+ Micro is required to support 72-cell/144 half cell modules. Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA (DC) 107-60-2-US IQ7PLUS-72-2-US Commonly used module pairings' 235W-350W+ 235W-440W+ Module compatibility 60-cell/120 half -cell PV modules 60-cell/120 half -cell and 72- only cell/144 half -cell PV modules Maximum input DC voltage 48V 60V Peak power tracking voltage 27V-37V 27 V - 45 V Operating range 16V-48V 16V-60V Min/Max start voltage 22 V / 48 V 22 V / 60 V Max DO short circuit current (module Isc) 15A 15A Overvoltage class DO port I 1 11 Do port backfeed current 0 A 0 A PV ai ray configuration 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) IQ 7 Microinverter IQ 7+ Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal (L-L) voltage/range7 240 V/ 208V/ 240 V / 208V/ 211-264 V 183-229 V 211-264 V 183-229 V Maximum continuous output current 1,0 A (240 V) 1,715 A (208 V) 1.21 A (240 V) 1.39 A (208 V) Nominal frequency 60 Fla 60 Hz Extended frequency range 47 - 68 Hz 47 - 68 Fiz AD short circuit fault current over 3 cycles 5,8 Arms 5,8 Arms Maximum units per 20 A (L-L) branch circuit! 16 (240 VAC) 13 (208 VAC) 13(240VAC) 11 (208 VAC) Overvoltage class AC port III [if AC port backfeed current 18 mA 18 mA Power factor selling 1,0 1,0 Power factor (adjustable) 0.85 leading ... 0.85 lagging 0.85 leading.., 0.85 lagging IFFICIENCY @240 V @208 V @240 V @208 V Peek eff dency 97.6 % 97.6 % 97.5% 973 % CEC weighted efficiency 97,0% 97.0% 97.0% 97.0% MECHANICAL DATA Wr i# -i -e-m-, p- erat —ur e' _r"an­g`e'­­ -40"C to +65°C Relative humidity range 4%to 100% (condensing) Connector type MC4 (or Amphenol H4 UTX with additional Q-DCC-5 adapter) Dimensions (HxWxD) 212 mm x 175 mm x 30.2 rom (without bracket) Weight 1,08 kg (2.38 lbs) Cooling Natw at convection - No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class It double -insulated, corrosion resistant polymeric enclosure Environmental category/ UV exposure rating NEMA Type 6 / outdoor FEATURES Cornrnunication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DO connectors have been evaluated and approved by UL for use as the load -break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class 8, ICES-0003 Class B, CAN/CSA-C22.2 NO, 1071-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer's instructions. 1. No enforced DC/AC ratio. See the compatibility calculator at h-Ups�//enphase.com/en-us/su.o.00rt/m le-Qcrapaubi-Ifty. 2. Nominal voltage range can be extended beyond nominal if required by the utility, 3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. !=,�a ENPHASE. To learn more about Enphase offerings, visit enphase.corn ENPHASE. To learn more about Enphase offerings, visit enphase.com %1_01v J1 2020 n p NiS F E .�, e'a y Arig' t es, e r Jed. E n p a s e, t e Eno Na s e c g c,, E n p �111 .se Q 7 E �c h a s, e 1 Q 7 E n p h as,-,, 1 Q B a e r y, Fnphase Effliah"e,., _riphasvo'y, af 0 01er tradct ndfKs cr sllCe, r an' -.a,ks or E, P' ase D le? gy, in;;. Cota su,,je­_ to charge, 2020-08- 1; 2 h. Enp!,Wse Networking Enphase �j- LIb I tU To barn more about Enphase offerings, visit n s€ xa The Ertipha e IQ Combirir 4/4C with Enphase IQ Gateway and integrated LTE-% l cell modem (included only with IQ Combiner 4C) consolidates interconnection equipment into a single enclosure and streamlines IQ microinverters and storage installations by providing a consistent, pre -wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. Smart Includes IQ Gateway for communication and control Includes Enphase Mobile Connect cellular modern (CELLMODEM-M2-06-SP-€I5), included only with IQ Combiner 4C Includes solar shield to match Enphase IQ Battery aesthetics and deflect heat Flexible networking supports WI-Fi, Ethernet, or cellular Optional AC receptacle available for PLC bridge Provides production metering and consumption monitoring Centered mounting brackets support single stud mounting Supports bottom, back and side conduit entry Up to four 2-pole branch circuits for 240 VAC plug-in breakers (not included) BOA total PV or storage branch circuits Durable NRTL-certified NEMA type 3R enclosure Five-year limited warranty Two years labor reimbursement program coverage included for both the ICI Combiner SKU's UL listed IQ Combiner 4C (X-IQ-AM1-24€l-4C) IQ Combiner 4C with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering (.ANSI C12.20+t-0.5`) and consumption monitoring (+t-2.5%). Includes Enphase Mobile Connect cellular modem (CELLMODEM-Ml-06-SP-05), a plug -and -play industrial -grade cell modem for systems up to 60 1 nicroinverters. (Available in the US, Canada, Mexico, Puerto Rico, and' he US Virgin islands, where there is adequate cellular service in the installation area.) Includes a silver solar sh€eld to match the IQ Battery and €Q System Controller and to deflect heat. ACCESSORIES AND REPLACEMENT PARTS (not included, order separately) Circuit Breakers Supports Eaton SR2.10. BR215. 3R220, BR230, BR240, BR260, and BR260 circuit breakers. BRK 10A-2-240V Circuit breaker, 2 pole, 10A, Eaton, BR210 9I%K-15A-2-240V circuit breaker, 2 ,pole, 15A, Eaton BR215 BRK-20A-2P-240V Circuit breaker, 2 pole, 20A Eaton BR220 SRK-15A-2P-24OV-B Circuit breaker, 2 pole, 15A, Eaton BR2158 with hold down kit support BRK-20A-2P-24OV-3 Circuit breaker, 2 pole, 20A, Eaton BR220B with hold down kill support EPLC-01 Power line carrier (communication bridge pair), quantity- one pair XA-SGLARSHIELD-ES Replacement solar shield for IQ Combiner 4i4C xA-PLUG-120-3 Accessory receptacle for Power Line Carrierin IQ Combiner 414C (sequiredfor EPLC-01) XA-ENV-PCBA-3 Replacement IQ Gateway printed circuit board (PCB) for Combiner 4l4C ELECTRICAL SPECIFICATIONS System voltage 120/240 VAC, 60 Hz Eaton BR series ousbar rating', 125 A Max. continuous current rating 65 A. Max. continuous current rating (Input from riv/s'torage) 64A Max. fuselcircuit rating (output) 90 A. Branchcircuits (solar and/or storage) no to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included) Max. total branch circuit breaker rating (input; 80A of distributed generation / 95A ;with IQ Gateway breaker included Envoy breaker 1 DA or 15A rating GEISIerrensfEaton included Production metering CT 200 A solid core pre -installed and wired to IQ Gateway Weight 7.5 kg (16.5lbs) Ambient temperature range i -40' C to+46' C (-401 to 1151 F) Cooling Natural convection, Plus heat shield Enclosure environmental rating Outdoor, NItTL-certlhed, NEMA type 3R, polycarbonate construction Wire sixes 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors: • 60 A breaker branch input: 4 to 1/0 AWG copper conductors Main lug combined output: 10 to 210 AWG copper conducive Neutral and ground:'14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. INTERNET CONNECTION OPTIONS Cellular CELLMQUEM-MI-06-SP-05, CELLMODEM-M l- i6-AT-05 (4G based LTE-M1 cellular modem). Note that an Enphase Mobile Connect cellular modem is required for all Ensemble installations - Ethernet Optional, 802.3,CaiSE (or Cat 6) UTP )ethernet cable (not included) COMPLIANCE Compliance, lit Gateway UL 60601-1(CANCSA 212 No, 61010-1 To learn more about Enphase offerings, visit 2022 "-phase Energy. All rights reserved. Enphase, the Enphase ogc, IQ Combiner 4I4C, and other names are t;aden-:arks of -r.phase Energy, Inc. Data subject to change. 02-'4-2022 _IFWI� IRONRIDGE Over their lifetime, solar panels experience countless but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. XR Rails are the structural backbone preventing these results. They resist uplift, protect against buckling and safely and efficiently transfer loads into the building structure. Their superior spanning capability requires fewer roof attachments, reducing the number of roof penetrations and the amount of installation time. ISM NX0,M Sloped roofs generate both vertical and lateral forces on mounting rails which can cause them to bend and twist. The curved shape of XR Rails is specially designed to increase strength in both directions while resisting the twisting. This unique feature ensures greater security during extreme weather and a longer system lifetime. Compatible with Flat & Pitched Roofs XR Rails are IronRidge offers compatible with a range of tilt leg FlashFoot and options for flat 0',_ A other pitched roof roof mounting attachments. applications. All XR Rails are made of 6000-series aluminum allay, then protected with an anodized finish. Anodizing prevents surface and structural corrosion, while also providing a more attractive appearance. ..... . . ....... ­"­ N 1',la, ......... XR10 XR10 is a sleek, low -profile mounting rail, designed for regions with light or no snow. It achieves spans up to 6 feet, while remaining light and economical. 6'spanning capability Moderate load capability Clear & black anodized finish Internal splices available W# 1 0 92 9 NUMN XR100 is the ultimate residential mounting rail. It supports a range of wind and snow conditions, while also maximizing spans up to 10 feet. 10'spanning capability Heavy load capability Clear & black anodized finish Internal splices available XR1000 is a heavyweight among solar mounting rails. It's built to handle extreme climates and spans up to 12 feet for commercial applications. 12'spanning capability Extreme load capability Clear anodized finish Internal splices available 0 to, 0 . . M # N W. 11 op lo9w9 9 9 - KZW .44, IRONRIDGE UFO Family of Components System Diagram Simplified Grounding for Every Application The UFO family of components eliminates the need for separate grounding hardware by bonding solar modules directly to lronRidge XR Rails. All system types that feature the UFO family —Flush Mount, Tilt Mount and Ground Mount —are fully listed to the UL 2703 standard. I 51167INT module and the rail, resulting in many parallel grounding paths throughout the system. This leads to safer and more rek.-ble instQ*-.bon-,.—_ Stopper Sleeve The Stopper Sleeve snaps onto the UFO, converting it into a bonded end clamp. BOSS" Splice Bonded Structural Splice connects rails with built-in bonding teeth. No tools or hardware needed. N• • �-T A single Grounding Lug connects an entire row of PV modules to the grounding conductor. Universal Fastening Object (UFO) The UFO securely bonds solar modules to XR Rails. It comes assembled and lubricated, and can fit a wide range of module heights. The bonding bolt attaches and bonds the L-foot to the rail. It is installed with the same socket as the rest of the system. 0 UFO (5,,"1" Stopper Sleeve e Grounding Lug ED BOSS- Splice Ground Wire 9 Approved Enphase microinverters can provide equipment grounding of lronRidge systems, eliminating the need for grounding lugs and field installed equipment ground conductors (EGC). A minimum of two microinverters mounted to the same rail and connected to the same Engage cable is required. Refer to installation manuals for additional details. The lronRidge Flush Mount, Tilt Mount, and Ground Mount Systems have been listed to UL 2703 by Intertek Group plc. 11L 2703 is the standard for evaluating solar mounting 5*%�P• mechanical connections over an extended period of time in extreme outdoor environments. z 7", �Go to IronRidge.com/UFO ElevatedL-Mount I QMLM / OMLM-ST Water Seat• •s 2,00 ,08 — i.0 . pti< n 90 �s.Tv s '.. O „O 1542.50 . QMLM IT NO. EM DESCRIPTION QTY. i 1 FLASHING, ROUNDED CORNERS, 9" X 12' X .040", .438" HOLE, 5052, 1 MILL 2 L-FOOT, 2" X 3.30" FOR .438" O.D. FASTENER, 2-1 /16" SLOT, 6061- 1 T6/6005A-T61, MILL 3 WASHER, SEALING, 5/16" ID X 3/4" OD, EPDM BONDED SS 1 4 LAG SCREW, HEX HEAD, 5/16" x 4", 18-8 SS 1 *5 STRUCTURAL SCREW, QMPV, T-30 HEX WASHER HEAD, 5/16" X 4-1/2", 1 18-8SS 4.. 34 QMLM-ST ft .ETAPYANC .IR,EHTII THE INFORMATION CONTAINED IN THIS DRAWING E THE SOLE PROPERTY OF QUICK MOUNT PY. ANY REPRODUCTION N PART OR AS A WHOLE WITHOUT THE wxmFN PCRMas QN QF Qu cc MGUNr Pv¢PxoHnTr-D. COPYRIGHT 02"79 QUICK MOUNT PY 5 BI 7.2.3-44 4 * STRUCTURAL SCREW AVAILABLE ON QMLM-ST VERSIONS ONLY AVAILABLE IN MILL, AND BLACK FINISHES Quick Mount W TITLE: QMLM & QMLM-ST: L-MOUNT, 2- 1 / 16" SLOT DIMENSIONS ARE IN INCHES TOLERANCES: -- FRACTIONAL- 1/8 DO NOT SCALE DRAWING TWO PLACE DECIMAL t,19 THREE PLACE DECIMAL -.094 3 2 SIZE DRAWN BY: AAP - REV .DATE: 4/4/2019 11 SCALE: 1:4 WEIGHT:0.7565 SHEET 1 OF I 1 Quick Mount PV RESPECT THE ROOF I=1 Ti 6tZ�j Gl `.Z: �I:1 Installation Tools Required: tape measure, roofing bar, chalk line, stud finder, caulking gun, sealant compatible with roofing materials, drill with 7/32" or 1/8" bit, drill or impact gun with 1/2" socket. Locate, choose, and mark centers of rafters to be mounted. Select the courses of shingles where mounts will be placed. If attaching with tag bolt use a 7/32" bit (Lag). Use a Ya" bit (ST) for attaching with the structural screw. Drill pilot hole into roof and rafter, taking care to drill square to the roof. Do not use mount as a drill guide. Drill a 2" deep hole into rafter. Prepare lag bolt or structural screw with sealing washer. Using a 1/2-inch socket on an impact gun, drive prepared lag bolt through L-foot until L-foot can no longer easily rotate. DO NOT over -torque. NOTE: Structural screw can be driven with T-30 hex head bit. BI7.2.3-44 Carefully lift composition roof shingle with roofing bar, just above placement of mount. Remove nails as required and backfill holes with aproved sealant. See "Proper Flashing Placement" on next page. Insert flashing between 1st and 2nd course. Slide up so top edge of flashing is at least 3/4" higher than the butt -edge of the 3rd course and lower flashing edge is above the butt -edge of 1st course. Mark center for drilling. Clean off any sawdust, and fill hole with sealant Place L-foot onto elevated flute and rotate L-foot to compatible with roofing materials. desired orientation. You are now ready for the rack of your choice. Follow all the directions of the rack manufacturer as well as the module manufacturer. NOTE: Make sure top of L-Foot makes solid contact with racking. Apr-2019 Rev 6