Loading...
HomeMy WebLinkAbout22-5023WR?111.III "MIII 5335 Eighth Street Zephyrhills, FL 33542 Phone: (813) 780-0020 Fax: (813) 780-0021 BAR-005023-2022 Issue Date: 11/01/2022 REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. ffm(!- I =0 I �411- I 11111iii U.omplete Plans, Specifications add fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNATURE PE IT OFFICEV PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER I INSTR#2022233945OR BK10715 PG3348 Page 1 of 1 10/31/2022 12:44 PM Rcpt: 2519008 Rec: 10.00 DS: UID IT: 0.00 Nikki Alvarez-Sowles, Esq., Pasco County Clerk & Comptroller 4 Parmil No. Parcel 10 No NOTICE OF COMMENCEMENT State of CourIty, Of THE UNDERSIGNED hereby gives notice that Improvement will be made to certain real property, and in accordance with Chapter 713, Florida $tamrrs, the following information is provided in this Notice of Commencement I Description of Property: P Street Address: Flb I 2. General 3. Owner If the Lessaa,6antrvcled for the enprovement: Interest in Property: r-, r fLC4, Name of Fee Simpte Tftleholder�. (it different from Owner Wed above) City Stsie 4. Contractor: It r- 11 ---- - -- — ------- Address CRY State Contractors Telephone No.: S. Surely: Name Address- Cily State Amount of Bond: S Telephone No,: 6. Lender. Nam Address city stale Lenders Telephone No.: 7. Persons vAthin the State of Florida designated by the owner upon whom notices or other documpro enis may be served as pvided by E Section 713.13(1)(a)(7), Florida Stalutes:, Name Address Telephone Number 61 Designated Person: 8, In addition to himsell, the ovener designates of — to recetvir a copy or the Lienorii Notice as provided in Section 713.134 Mb). Florida Stamm Telephone Number of Person or Entity Designated by Owner, 9. Expiration date of Notice of Commencement (the expiration date may not be before the completion of construction and final payment to the contractor, but will be one year from the dale of recording unless a different date is spechieft WARNNG TO OWNER: ANY PAYMENTS MADE.BYTHE OWNEWAFTER THE EXPIRATION Of THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER-CRAPTER713. PARTI, SECTIGN71113, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR�IMPROVEMENTS To YOUR PROPERTY. A.NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION: IF YOU INTEND TO OBTAIN FINANCING. CONSULT VWTH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. E 0 Umynder knowPenalty alge Of err I declare that I have read Me foregoing notice of commencement and Met the facts stated therein are true to the best of leanlrekef0 J) E STATE OF FLORIDA 0 C U) OUNTY OF PASCO 0 a or Lessee's Authorized M Sqjname of Owner Or 0 Cy LIUJ signaler 'ys TWO/ofte M The foregoing irmtrunvent was acknowl difed W this at 4j, Mu 0 M 2. - I 0 as 4i � I' " (type of authority, e.g., 6flic4r,'trustee, attorney in fact) for V 0 U- L4 {name on affof hom-Instrument 0) M Z" .,a 1 �c Personally Known 0 QB Produced I Notary signature 0 E (0 0 IV t4 Type of Iderafficalren Produced Name (Print) 0 01 0 4 z 0 Cl. CO K DEL C07TO My COMMISSION # GG 963M Nawy ES-* JW* 20,2024 T?wu v.pdataftsMoticecommencement 813-780-0020 City of ZephyrhillS Permit Application Fax-813-780-0021 Building Department 1 INSTALL REPAIR PROPOSED USE SFR Comm TYPE OF CONSTRUCTION BLOCK =BUILDING $ `'tit ✓' a A �i ✓ td ELECTRICAL PLUMBING $ MECHANICAL $ GAS ROOFING SIGN ® ® DEMOLISH OTHER STEEL VALUATION OF TOTAL CONSTRUCTION AMP SERVICE PROGRESS ENERGY W.R.E.C. + i--- - I I i P goneo-te v4ftnotarized letter from owner authorizing same OVER (copyof contract required) General Notes A. CONCRETE & FOUNDATION DESIGN: 1, ALL CONCRETE GRADE BEAMS AND FOOTINGS SHALL BE 3000 PSI MINIMUM. 2- ALL CONCRETE FILLED SUPPORTED SLABS SHALL BE 2500 PSI MINIMUM, 3 1/2" NOMINAL THICKNESS. 3. 3000 PSI FIBERMESH (3/4" PER CUBIC YARD MIN.) MEETING APPROPRIATE ACI AND ASTM REQUIREMENTS MAY BE USED IN LIEU OF WELDED WIRE MESH 4. ALL SLABS ON GRADE SHALL BE 4" THICK WITH FIBERMESH. TERMITE TREATMENT OF SOIL BENEATH SLAB IS NOT REQUIRED IF SLAB DOES NOT ABUT A WOOD FRAME STRUCTURE. NO WOOD FRAME STRUCTURE, MAY BE BUILT ADJACENT TO OR ON TOP OF A SLAB WITHOUT TREATING THE SOIL FOR WOOD DESTROYING ORGANISMS. 5. ALL REINFORCING SHALL CONFORM TO ASTM A615, BE GRADE 60 (60 KSI MIN.) DEFORMED BARS, #3 BARS MAY BE GRADE 40 6. ALL OVER POUR CONCRETE FILLED SUPPORTED SLABS SHALL BE 3000 PSI MIN., 2" MINIMUM. THICKNESS. 7. SOIL BEARING PRESSURE SHALL BE A MINIMUM OF 1500 PSF. & THE CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING: OPC (PORTLAND CEMENT TYPE ],- ASTM C 150). AGGREGATES - #6 STONE, ASTM C 33 SIZE NO. 67 LESS THAN 3/4". AIR ENTRAINING +/- 1% - ASTM C 260. WATER REDUCING AGENT - ASTM C 494. CLEAN POTABLE WATER. OTHER ADMIXTURES SHALL NOT BE PERMITTED. 9. METAL WELDED WIRE SHALL CONFORM TO ASTM A 185. 10. PREPARE & PLACE CONCRETE ACCORDING TO AMERICAN CONCRETE INSTITUTE MANUAL STANDARD PRACTICE, PART 1, 2, & 3 ALONG WITH HOT WEATHER CONDITIONS RECOMMENDATIONS. 11. IF UTILIZING EXISTING CONCRETE FOR FOUNDATION, CONCRETE SHALL BE A MINIMUM OF 4" IN THICKNESS, VISIBLY FREE OF ANY STRUCTURAL EXCESSIVE CRACKING, SPALLING OR OTHER DETERIORATION. B. MASONRY: i. CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR. 2.ALL MORTAR SHALL BE OF TYPE M OR S. 3.ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 3/8". 4.PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS 5'-0" IN HEIGHT. C. ALUMINUM: I. ALL STRUCTURAL ALUMINUM SHALL CONFORM TO THE MINIMUM REQUIREMENTS OF 6005-T5 FOR ALLOY WIT14 A MINIMUM THICKNESS OF 0.040" FOR SUPPORTING MEMBERS. 1 WHERE KICK PLATES ARE USED A MINIMUM THICKNESS OF 0.024" SHALL APPLY. 3. STRUCTURAL ALUMINUM DESIGN CONFORMS TO "PART I -A - SPECIFICATIONS FOR ALUMINUM STRUCTURES - ALLOWABLE STRESS DESIGN" OR "PART I -B - SPECIFICATIONS FOR ALUMINUM STRUCTURES - BUILDING LOAD AND RESISTANCE FACTOR DESIGN" OF THE CURRENT ALUMINUM DESIGN MANUAL PREPARED BY THE ALUMINUM ASSOCIATION, INC.WASHINGTON D.C. THE FLORIDA BUILDING CODE. 7TH EDITION (CHA-PTER 16 STRUCTURAL DESIGN & CHAPTER 20 ALUMINUM). 4. WHERE ALUMINUM COMES INTO CONTACT WITH STEEL, OR PRESSURE TREATED LUMBER PROVIDE DIELECTRIC SEPARATION. 5. ALUMINUM MEMBERS SHALL BE STITCHED WITH NO LESS THAN #10 SMS 6" FROM THE ENDS AND 12" ON CENTER, IF USING #12 SPACING MAY BE 24" ON CENTER. 6. VINYL AND ACRYLIC PANELS SHALL BE REMOVABLE. THEY SHALL BE IDENTIFIED WITH A DECAL ESSENTIALLY STATING "REMOVABLE PANEL SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 MPH". DECAL SHALL BE PLACED SO IT IS VISIBLE WHEN PANEL IS INSTALLED. D. FASTENERS: i. ALL LAG BOLTS SHALL CONFORMTO STAINLESS STEEL TYPE 300 18-8, WITH STANDARD FLAT WASHER UNLESS MANUFACTURER GALVANIZES BOLTS SPECIFIES FOR USE WITH ACQ PRESSURE TREATED WOOD. 2, HEX BOLTS HAS TO BE ASTM A 325, PLATED WITH STANDARD FLAT WASHERS AND NUTS. 3, ALL CONCRETE SCREWS SHALL BE, SIMPSON, HILTI, BAWL, TAPCON, REDHEAD, DYNABOLT, OR APPROVED EQUAL. 4, ALL METAL TIES AND ASSOCIATED ACCESSORIES SHALL BE HOT DIPPED GALVANIZED. 5. ALL LAG BOLTS SHALL HAVE A MINIMUM EMBEDMENT OF 8X BOLT DIAMETER INTO STRUCTURAL FRAMING (G=.42 MIN.). 6. LAG BOLTS AND SCREWS INTO WOOD FRAMING SHALL BE PROVIDED WITH PILOT HOLES HAVING A DIAMETER NOT GREATERTHAN 70 PERCENT OF THE THREAD DIAMETER OF THE BOLT OR SCREW, ALL LAG BOLTS AND SCREWS SHALL BE INSERTED IN PILOT HOLES BY TURNING AND UNDER NO CIRCUMSTANCES BY DRIVING WITH A HAMMER. 7. ALL EXPANSION ANCHORS SHALL BE DESIGNED IN ACCORDANCE WITH THE SPECIFIC MANUFACTURER'S REQUIREMENTS AND ALLOWABLE LOADS AND SHALL ONLY BE APPLIED IN CONDITIONS ACCEPTABLE TO MANUFACTURER FASTENERS SHALL BE MINIMUM OF SAE GRADE #5 OR BETTER ZINC PLATED. 8. ALL FASTENERS CONNECTING ALUMINUM COMPONENTS OR PRESSURE TREATED LUMBER ARE STAINLESS STEEL TYPE 300 18-8, UNLESS MANUFACTURER GALVANIZED BOLTS SPECIFIES FOR USE WITH ACQ PRESSURE TREATED WOOD, OR OTHERWISE NOTED ON PLANS. 9. ALL FASTENERS SHALL COMPLY WITH ASTM A153. 10. ALL CONNECTORS SHALL COMPLY WITH ASTM A653 CLASS G-185. 11. FOR SMS, THE MINIMUM CENTER -TO -CENTER SPACING SHALL BE 3/4" AND MINIMUM CENTER -TO -EDGE SHALL BE 1/2" UNLESS NOTED OTHER WISE. E. REFERENCE STANDARDS: ASTM E 119 ASTM E 1300 ASCE 7 -16 AAASM35, AND SPEC. FOR ALUMINUM PART 1-A, & 1-B ASTM C94 ASTM C150 ASTM C33 ASTM C260 ASTM C494 ASTM A615 ASTM A185 FLORIDA BUILDING CODE (CHAPTERS 16,20 AND 23) 7TH EDITION CURRENT ALUMINUM DESIGN MANUAL F. ABBREVIATIONS: THE FOLLOWING LIST OF ABBREVIATIONS IS NOT INTENDED TO REPRESENT ALL THOSE USED ON THESE DRAWINGS, BUT TO SUPPLEMENT THE MORE COMMON ABBREVIATIONS. 1. TYP TYPICAL 2. SIM SIMILAR 3. CON -- UNLESS OTHERWISE NOTED 4. CONT -- CONTINUOUS S. VIE -- VERIFY IN FIELD G. RESPONSIBILITY: i. ALL SITE WORK SHALL BE PERFORMED BY A LICENSED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDINANCES, ETC. 1 CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND DETAILS, NOTIFYING ENGINEER OF ANY DISCREPANCIES BETWEEN DRAWINGS, FABRICATED ITEMS, OR ACTUAL FIELD CONDITIONS, 3. THESE DRAWINGS REPRESENT THE ACCEPTABILITY OF THE 'SUNROOM'ROOM ADDITION ELEMENTS AS PROVIDED BY THE CONTRACTOR- 4. ALL DETAILS ON THESE DRAWINGS ARE ENGINEERED BASED ON INFORMATION PROVIDED BY THE CONTRACTOR AND MANUFACTURER, 5 ANY DETAILS NOT SHOWN ARE TO BE ENGINEERED BY A LICENSED P.E. IN ACCORDANCE WITH STANDARD ENGINEERING PRACTICES. H. MISCELLANEOUS: 1. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME WITHOUT A MANUFACTURER'S HOST BEAM. IF NO HOST BEAM IS PRESENT A SEPARATE 4TH WALL SUPPORT SYSTEM SHALL BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. 2. IF ENCLOSURE CONTAINS A SWIMMING POOL OR SPA, THE ENCLOSURE SHALL COMPLY WITH RESIDENTIAL SWIMMING BARRIER REQUIREMENTS OF THE FBC 7TH EDITION R 4501_17.1 IN ITS ENTIRETY. 3. DOOR LOCATIONS MAY BE DETERMINED IN THE FIELD BY CONTRACTOR, 41 IF PAVERS ARE UNDER ALUMINUM MEMBERS THEY SHALL HAVE EPDXY AD14ESIVE TO CONCRETE OR IF USING GROUT, ENSURE BONDING AGENT IS USED FIRST. 5. SCREENING MATERIAL SHALL BE 18X14X0.0I3 OR EQUIVALENT DENSITY SCREEN MESH ONLY UNLESS NOTED OTHERWISE. 6. EMERGENCY ESCAPE & RESCUE OPENING PER FBC R310.1 SHALL BE VERIFIED BY CONTRACTOR & BUILDING OFFICIAL 7. ENCLOSED ADDITIONS TO MANUFACTURED HOMES SHALL NOT CHANGE THE EXIT FACILITIES FOR EGRESS PER HUD 3280.105, (a) THROUGH (a)(2)(iv), SO THAT THE DISTANCE TO EXIT DIRECTLY OUTSIDE FROM ALL BEDROOMS IS LESS THAN 35% AND, SO THAT TWO EXITS I-RECTLY OUTSIDE ARE STILL MAINTAINED. A CARPORT OR SCREEN ROOM SHALL BE CONSIDERED AS OUTSIDE. NON -HABITABLE SUNROOMS OR HABITABLE LIVING SPACE MAY BE ADDED WHERE AN EXIT DOOR WAS LOCATED AS LONG AS A NEW EXIT DOOR IS ADDED AND MEETS THE REQUIREMENTS OF HUD 3280.105. Mill! 131112111 1. ULTIMATE DESIGN WIND SPEED Vult, (3 SECOND GUST): 130 MPH NOMINAL DESIGN WIND SPEED Vasd: 101 MPH 2. RISK CATEGORY: 1 3. WIND EXPOSURE: B ,t INTERNAL COEFFICIENT: COVERED PATIO, SCREEN ROOM (OPEN STRUCTURE): 0.0 S. WIND LOADS: FACTOR APPLIED TO WIND LOADS FOR ALLOWABLE STRESS DESIGN: 0.6 SOLID ROOF (MWFRS): 20 PSF SCREEN WALLS: 23 PSF COMPONENT & CLADDING PRESSURES: ROOF ZONE 1: 12.4/-48.4 PSF, ZONE 2: 12.4/-63.9 PSF, ZONE 3: 12.4/-87.1 PSF 6. FOUNDATIONS PER 'A` OF GENERAL NOTES AND SITE SPECIFIC DETAIL. EXISTING 4" CONCRETE SLAB, 2500 PSI CONCRETE W/ 6"X6"-#10WWM OR 3000 PSI FIBERMESH AND FOOTER SHALL BE ADEQUATE TO RESIST THE UPLOADS FOR THE PROPOSED STRUCTURE. 7. SOLID ROOF TYPE: 3"X48" COMPOSITE PANELS, FL 7561 OR EQUIV. utsuffelfilm 2 x 2: ---------------------------------------2" x 2" x 0.044" 3 x 2: ---------------------------------------3" x 2" x 0.050" 2 x 3: --------------------------------------- 2" x 3" x 0.050" 2 x 3: ---------------------------------------2" x 3" x 0,070" 2 x 4: ---------------------------------------2" x 4" x 0.050" 2 x 5: ---------------------------------------2" x S" x 0.050" 3 x 3: ---------------------------------------3 x 3" x 0.072" 3 x 3: ---------------------------------------3 x 3" x 0.093" 3 x 3: --------------------------------------- 3 x 3" x 0.125" 4 x 4: --------------------------------------4 x 4" x 0.125" OPEN BACK SECTIONS 1 x 2:---------------------------------------- 1" x 2" x 0.040" 1 x 3: ----------------------------------------1" x 3" x 0.045" 2 x 2 Snap: ---------------------------------- 2" x 2" x 0,045" 2 x 3 Snap: ---------------------------------2" x 3" x 0.050" 2 x 4 Snap:---------- --------- --------- 2" x 4" x 0.045" 2x4SMB: ---------------------- 2" x 4" x 0,044" x 0.100" 2x5SMB: ---------------------- 2" x S" x 0.050" x 0.118" 2x6SMB: ---------------------- 2" x 6" x 0.050" x 0.120" 2x7SMB: ---------------------- 2" x 7" x 0.057" x 0.120" 2 x 8 SMB: ---------------------- 2" x 8" x 0.072" x 0.224" 2x9SMB: ---------------------- 2" x 9" x 0.072" x 0.224" 2 x 10 SMB: ------------------- 2" x 10" x 0.092" x 0.374" ALL WORK SHALL UDAIPLY'VVIII-H PREVAX CODES r-L'ORIDA BUILICANG CODE, NAT MAL ELECTRIC CODE. AND THE Cl*r--( OF ZEF+AYRH US ORDINANCESS' REVIEVIVDA,-,,'E� CITY OP, zpp;-mp�_n PLAN EKA INDEX: S-1 GENERAL NOTES S-2 PLANS AND ELEVATIONS S-3 COVERED PATIO DETAILS S-4 SCREEN ROOM DETAILS I HEREBY CERTIFY THAT I HAVE REVIEWED THIS PLAN AND FOUND IT TO BE IN COMPLIANCE WITH ASCE 7-16 AND FBC 7TH EDITION RESIDENTIj�WfjlST11NGBUILDING a 1 v -4, \C E z 0, OF NA 1,, k ` PROF SSIOA 11SE 4 1 "AL ENGINEER OF RECORD David W. Smith P.E. FLORIDA LICENSE NUMBER: 53608 Thomas L. Hanson P.E. FLORIDA LICENSE NUMBER: 38654 Ian J. Foster P.E. FLORIDA LICENSE NUMBER: 93654 Joel Falardeau P.E. FLORIDA LICENSE NUMBER: 70667 Erik Stuart P.E. FLORIDA LICENSE NUMBER: 77605 FBC Plans & Engineering Services, Inc. 5344 9th St. Zephyrhills, Fl. 33542 Phone: (813)838-0735 Email: erb@fbcplans.com Website: www,fbcplans.com C.O.A. - #29054 DATE: 10/14/2022 Igo REVISION: I DATE: I JOB# 221011108 1013 BOYCE 3107 KRESTERBROOKE LN ZEPHYRHILLS, FL. 33540 SUNSTATE ALUMINUM M S.M.B. DEPTH S.M.B. WEB TUBE WALL CORROSION RESISTANT UPLIFT I HEREBY CERTIFY THAT I HAVE REVIEWED "W WALL "T" SIZE CAPACITY THIS PLAN AND FOUND IT TO BE IN 4- .045" .06' (2) 3/8- BOLTS, NUTS, WASHERS 1,720 LBS COMPLIANCE WITH ASCE 7-16 AND FBC 7THEDITION RESIDENTIAL AND EXISTING 5. .050, .06' (2) 318- BOLTS, NUTS, WASHERS 2,550 LBS BUILDING — %10 4 t j 61, .0501, .061 (3) 3/8- BOLTS, NUTS, WASHERS 2,550 LBS 7" 055" .0611 (3) 3/8' BOLTS, NUTS, WASHERS 3,500 LBS . 7' .05511 1 .09, (3) 3/8" BOLTS, NUTS, WASHERS 3,600 LBS 011 1 7" .0551, .125" (3) 3/8- BOLTS, NUTS, WASHERS 4,500 LBS 4\ 81 .072" 06.' (4) 3/8" BOLTS, NUTS, WASHERS 5,500 LBS " I 0 d I * 8- .072" .091, (4) 3/8'BOLTS, NUTS, WASHERS 7,000 LBS jo .072' .125" (4) 3/8"BOLTS, NUTS, WASHERS 7D LBS 6" MIN. 0� a RECOMMEND ALUMINUM FLASHING .072" 9" & .061, (4) 3/8" BOLTS, NUTS, WASHERS 7,000 LBS INSTALLED BELOW DRIP EDGE. 91, .072" (4) 3/8" BOLTS, NUTS, WASHERS .091, 8,900 LEE CAULK ALL SEAMS. 91, .082" 125" (4) 318- BOLTS, NUTS WASHERS 9,500 LES — 00 10" .092 M1 5- �(4) 3/8" BOLTS, NUTS, WASHERS I 1,OOOLBS I #Te ALUMINUM FLASHING ATTACHED NOTE: OTHER BOLT SIZES AND QUANTITIES MAY BE USED PER V W/ #8 X 3/4" TEK SCREW AT 12" O.C. SITE SPECIFIC PLANS AND CALCULATED UPLIFT CAPACITY REQUIRED A L COMPOSITE PANEL ROOF PROFESS O 0FESSI ENGINEER OF RECORD FASTEN PANELS TO 0�060" MIN. HEADER z w David W. Smith P.E. F- 2 CHANNEL W/ #10 X 3/4" TEK SCREW AT FASTEN COMPOSITE PANEL TO ALL BEAMS 0 8" O.C.TOP AND BOTTOM W/ # 10 TEK SCREW AND 1-1/4"0 NEOPRENE FLORIDA LICENSE NUMBER: 53608 w WASHER AT 8" O.C. (USE SCREW LENGTH EQUAL COMPOSITE FASTEN HEADER CHANNEL TO FASCIA TO COMPOSITE PANEL THICKNESS PLUS 1" MIN.) PANEL ROOF Thomas L. Hanson P.E. W/ 1/4"0 X 2-1/2" LAG SCREW AT 24" O.C., 2 ROWS STAGGERED. STRIP SEALANT FLORIDA LICENSE NUMBER: 38654 BETWEEN FASCIA AND HEADER CHANNEL Ian J. Foster P.E. COMPOSITE PANEL ROOF 2X SMB PER PLAN FLORIDA LICENSE NUMBER: 93654 CONNECTION AT FASCIA \\—(N) 3/8"THRU BOLTS, WASHERS, Joel Falardeau P.E. AND NUTS, CORROSION RESISTANT, FLORIDA LICENSE NUMBER: 70667 TYPICAL (SEE CHART) ALUMINUM POST / COLUMN PER PLAN E Erik Stuart P.E. FLORIDA LICENSE NUMBER: 77605 COMPOSITE ROOF, POST AND BEAM CONNECTION F13C Plans & Engineering Services, Inc. 5344 9th St. Zephyrhills, Fl. 33542 Phone: (813)838-0735 Email: erb@fbcplans.com Website: www.fbcplans.com C.O.A. - #29054 DATE: 10/14/2022 DRAWN BY: DENNIS W. DUNN FASTEN SMB TO RECEIVING CHANNEL W/ #10 X 3/4" TEK SCREW REVISION: DATE: (1 PER INCH OF BEAM HEIGHT) (2) 3/8"0 MACHINE BOLTS, ALUMINUM 3X3 POST STAGGERED, BOTH SIDES NUTS AND WASHERS OR (4) #14 X 3/4" TEK SCREWS EACH SIDE INTERNAL BASE RO 1 OPTION 1 R02 EXTERNAL BASE of— OPTION 2 11 GA. INTERNAL ALUMINUM BASE R03 o —U) PREDRILL VERTICAL FLANGES 2X SMB PER PLAN 01—pa z 2" X 2" X.125" ANGLES EXTERNALR04 a o 1-2i (4) V4"O CONCRETE ANCHORS 0 —D OR EQUIVALENT POST BASE W1 3" EMBEDMENT, 3" MIN. EDGE JOB# 22 1011 108 LU (2) 3/8"0 CONCRETE ANCHORS PER DISTANCE AND 2" MIN. SPACING 062 MIN. RECEIVING CHANNEL - CIA EXTERNAL FLANGE WITH 2" O.C. SPACING, JOB NAME &ADDRESS: FASTENED TO POST W/ #10 X 3/4" TEK <C 2-3/4" MIN. EMBEDMENT AND 3" MIN BOYCE SCREW (1 PER INCH OF BEAM CONCRETE EDGE DISTANCE HEIGHT) STAGGERED CONCRETE .' 3107 KRESTERBROOKE LN. ZEPHYRHILLS, FL. 33540 BEAM TO POST CONNECTION 3X3 ALUMINUM POST CONNECTION CONTRACTOR: TO CONCRETE BASE OR HEADER DETAIL SUNSTATE ALUMINUM COVERED PATIO DETAILS S-3 I HEREBY CERTIFY THAT I HAVE REVIEWED #10 TEK SCREW AND 1-1/4"0 #10 TEK SCREW AND 1 -1/4"0 THIS PLAN AND FOUND IT TO BE IN NEOPRENE WASHER AT 8- O.C. (USE COMPOSITE NEOPRENE WASHER AT 8" O.C. (USE COMPOSITE COMPLIANCE WITH ASCE 7-16 AND FBC 7TH 6" MIN. RECOMMEND ALUMINUM FLASHING SCREW LENGTH EQUAL TO COMPOSITE PANEL ROOF SCREW LENGTH EQUAL TO COMPOSITE PANEL ROOF EDITION RESIDENTIAL D EXISTING BUILDING % INSTALLED BELOW DRIP EDGE. PANEL THICKNESS PLUS I" MIN.) PANEL THICKNESS PLUS 1" MIN.) 'El `EXISTING O'CAULK ALL SEAMS. 4f 10 -ALUMINUM FLASHING ATTACHED V W/ #8 X 3/4" TEK SCREW AT 12" O.C. 360,9 _,2 COMPOSITE PANEL ROOF T 2X3 PATIO 2X3 PATIO EDGE 11 EDGE / END BEAM EDGE / END BEAM 0 0 "X 2" X 0.125" ANGLE z w \-FASTEN PANELS TO 0.060" MIN. HEADER 2X3 UPRIGHT 2ee -, �-%l - 11 V" -011 - I CHANNEL W/ #10 X 3/4" TEK SCREW AT W/ (3) #10 X 3/4" TEK SCREW 0 8" O.C.TOP AND BOTTOM EACH LEG, EACH SIDE OF UPRIGHT C/) 57< Uj FASTEN HEADER CHANNEL TO FASCIA (4) #10 X 4" TEK SCREW 2X3 OR 3X3 UPRIGHT PROFESSION AL O.C., 1/4"0 X 2-1/2" LAG SCREW AT 24" O�CINTO SCREW BOSS —A� - 2 ROWS STAGGERED. STRIP SEALANT ENGINEER OF RECORD BETWEEN FASCIA AND HEADER CHANNEL COMPOSITE PANEL ROOF, UPRIGHT, AND COMPOSITE PANEL ROOF, UPRIGHT, AND COMPOSITE PANEL ROOF EDGE END BEAM CONNECTION DETAIL EDGE / END BEAM CONNECTION DETAIL David W. Smith P.E. CONNECTION AT FASCIA OPTION (INTERNAL) OPTION (EXTERNAL) FLORIDA LICENSE NUMBER: 53608 E Thomas L. Hanson P.E. FLORIDA LICENSE NUMBER: 38654 Ian J. Foster P.E. - ALUMINUMCOILOR 2X2 MIN. OPTION #2 FLORIDA LICENSE NUMBER: 93654 VINYL SIDING KICK PLATE ATTACHED TO 0.062" MIN. ALUM. INTERNAL HINGE LOCATION------' t- Z E Joel Falardeau P.E. IX OPEN BACK ALUMINUM MEMBER OR EXTERNAL RECEIVING T < < --------- 7 -i ALUMINUM--�, 0 W1 (1) #10 X 3/4" TEK LD _j CHANNEL W/ (4) #10 X 3/4� a_ LD D- FLORIDA LICENSE NUMBER: 70667 C� POST - - - - - - - - af SCREW AT 8"O.C. TEK SCREWS INTO UPRIGHT a_ Uj LIJ of PER PLAN UPRIGHT OR BEAM AND (2) #12 X 3/4" TEK SCREWS LL E Erik Stuart P.E. FASTEN 1X OPEN il SNAP OR SELF EACH LEG INTO GIRT HINGE LOCATION FLORIDA LICENSE NUMBER: 77605 BACK TO ALUMINUM ALUMINUM COIL 11 MATING OR HOLLOW POST W/ #10 X 1-1/2" OR 11 0 TEK SCREW, 3" FROM VINYL SIDING IF VINYL SIDING USE MIN, FBC Plans & Engineering TOP AND BOTTOM 11 2X PER PLAN 2X PER P�LAN:j KICKPLATE 2X2X.044" VERTICAL Services, Inc. AND 12" O.C. UPRIGHTS AT 24" O.C. MAX. S344 9th St. II ATTACHED WITH 062" MIN. I HINGE LOCATION------' Zephyrhills, Fl. 33542 CLIP 1F Phone: (813)838-0735 1 Vj_ ANGLE W/ (2) #10 X 3/4" 0.062" MIN. ANGLEI 2X ALUM. NOTES: Email: erb@fbcplans,com TEK SCREW PER FLANGE, W1 (2) #12 X 3/4" TEK I UPRIGHT Website: www,fbcp1ansxom TOP, BOTTOM AND ON EACH SCREWS EACH LEG I PER PLAN 1. HINGES SHALL BE ATTACHED TO STRUCTURE W/ (3) #10 X 3/4" SIDE OF UPRIGHT, TYPICAL OPTION #1 1 TEK SCREW MINIMUM. C.O.A. - #290S4 1X OPEN BACK TO ALUM POST 2. DOOR SHALL BE ATTACHED TO ENCLOSURE W/ (2) HINGES MIN. ALUMINUM COIL OR VINYL SIDING 3. HINGES SHALL BE ATTACHED TO DOOR WITH (3) #10 X 3/4" DATE: 10114/2022 KICK PLATE TO ALUMIUM MEMBER CHAIR RAIL AND GIRT CONNECTIONS TEK SCREW. FASTEN A 1"X2"XO.044" TO UPRIGHT W/ #12 X 1-1/2" TEK SCREW AT 12" O.C. AND WITHIN 3" FROM END OF THE UPRIGHT. DRAWN BY: DENNIS W. DUNN TYPICAL SCREEN DOOR CONNECTION DETAIL REVISION: DATE: RO 1 2" X 2" X 0. 125" ANGLE 2X3 UPRIGHT (2) 2" X 2" X 0.125" ANGLE RO 2 (2) #12 X 3/4" TEK SCREW (TYPICAL EACH SIDE) RO 3 FASTENING UPRIGHT TO 1X2 OPEN BACK EXISTING (2) #12 X 3/4" TEK SCREW RO 4 ANGLE IF IX2 O.B. USED OR (1) 1/4" 0 CONCRETE I FASTENING UPRIGHT TO BLOCK WALL (3) #12 X 3/4" TEK SCREW ANGLE MIN. EMBED L-V- SCREW ANCHOR INTO EACH ANGLE 2X END BEAM 2X3 ----I IF 1X3 O.B. USED MENT (TYPICAL EACH SIDE) JOB # 22 PER PLAN UPRIGHT I (TYPICAL EACH SIDE) SHALL BE 2-3/4" 0 JOB NAME & ADDRESS: 4"0 MASONRY ANCHOR 1 0 0 08 =,7 (TYPICAL EACH SIDE) 0 1X2 O.B, BASE MEMBER EMBEDMENT MIN. I IX2 OR 1X3 O.B. BASE MEMBER (TYPICAL EACH SIDE) BOYCE [6 TOP AND BOTTOM (TYPICAL EACH SIDE) . . . .... ..; 2" X 2" X 1/8" X'BEAM DEPTH' -� A O.C. 3107 KRESTERBROOKE LN. 3/8" 0 CONCRETE SCREW RECEIVING CHANNEL 3/8" 0 CONCRETE SCREW W/ 1/4"0 MASONRY ANCHOR C so ANCHOR THRU ANGLE AND O.B. ZEPHYRHILLS, FL. 33540 ANCHOR THRU ANGLE AND O.B. W/ 2" EMBEDMENT MIN. INTO INTO CONCRETE AS SHOWN OR INTO CONCRETE AS SHOWN OR THRU ANGLE INTO CONCRETE AND WALL AND (4) #10 X 3/4" TEK 1X O.B. PER PLAN THRU ANGLE INTO CONCRETE AND CONTRACTOR: SCREW EACH SIDE INTO BEAM -LAL (MIN.} 1/4"0 CONCRETE SCREW ANCHOR 3" (MIN.) 1/4" 0 CONCRETE SCREW ANCHOR THRU O.B. 6" FROM ENDS AND THRU O.B. 6" FROM ENDS AND SUNSTATE ALUMINUM END BEAM TO HOST STRUCTURE DETAIL 24" O.C. BETWEEN UPRIGHTS. 3" (MIN.) 24" O.C. BETWEEN UPRIGHTS. MIN. EMBEDMENT SHALL BE 2-3/4" MIN. EMBEDMENT SHALL BE 2-3/4" SCREEN ROOM (TYPICAL EACH SIDE) (TYPICAL EACH SIDE) DETAILS 2X3 UPRIGHT W/ 1X2 OR I X3 O.B. BASE MEMBER 2X3 CORNER UPRIGHT AND 1X2 O.B. BASE MEMBER I I S-4