HomeMy WebLinkAbout22-5035City of Zephyrhills g­ I, 5335 Eighth Street amss " Zephyrhills, FIL 33542 BAR-0 -2022 Phone: (813) 780-0020 Fax: (813) 780-0021 Issue Date: 11/01/2022 REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies, accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNATURE PE iT6-FF-jCEfV It V ITHOUT APPROVED INSPECTION 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department +I III 1 .� %► i� Foe Simple Titleholder Name Fee Simple Titleholder Address WORK PROPOSED NEW CQNSTR ADD/ALT SIGN DEMOLISH INSTALL REPAIR PROPOSED USE SFRCOMM OTHER PE OF CONSTRUCTION SLACK FRAME STEEL DESCRIPTiON OF WORK 'v n e BUILDING SIZE SQ,FOOTAGE L% HEIGHT ILDING ®� ®� VALUATION OF TOTAL CONSTRUCTION ELECTRICAL $ AMP SERVICE PROGRESS ENERGY W.R.E.C. PLUMBING itf MECHANICAL $ VALUATION OF MECHANICAL'INST`ALLATiON } GAS ROOFING SPECIALTY OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY Gf k� i�f. SIGNATURE REGISTERED�FEECUFtR�EN��� .Address License c1 ?�S ELECTRICIAN COMPANY SIGNATURE t REGISTERED Y / "N FEE CURREN Y / N Address License PLUMBER COMPANY SIGNATURE REGISTERED Y / N FEE CURREN Y / N Address License #f MECHANICAL COMPANY SIGNATURE REGISTERED ;;Y;/N��FEEC�URREK Address License:# OTHER COMPANY SIGNATURE REGISTERED ;;N �FEECUR�REKY 1 N Address License IIIII1111// gill 11INN III INN 11/l1/111111111 all INN 111III 111111oil 1//11111 ESIDENiTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new' construction, Minimum ten (10) working days after submittal date. Required onsite,' Construction Plans, Stormwater Plans w/ Slit Fence Installed, Sanitary Facilities & 1=dumpster; Site Work Permit for subdivisions/lairge projects COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Rage; (1) set of Energy Forms. R-O-W Permit for new: construction: Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster, Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions, Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (AIC upgrades over $7500) ** Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER *(copy Reroofs if shingles Sewers Service Upgrades e.P INSTR#2022233946OR BK10715 PG3349 Page 1 of 1 10/31/2022 12:44 PM Rcpt: 2519008 Rec: 10.00 DS: 0.00 IT: 0.00 Nikki Alvarez-Sowles, Esq., Pasco County Clerk & Comptroller Permit No Parcel to No 2NOTICE OF COMMENC�MENIT' Stale of _10 r �i county of _ qSC THE UNOERVONCO hereby "a notice that Improvement v" he Made to Canan Tool PrOWY, and in accordance with Chaptar 713, Fladda Storms, the following Information Is provided in this Witt of Cenamenn. I 1. Description at Property. Parcel Identification No. 75: Street Address:, 2, Gonerof Description of Imenovemetit rbx 2) ne 1 Ovnor Informall or L" Internal! I If the LOS%ft contracted for the improvement: Address State Interest In Propkody:ift Name of Fee Slavic, Titleholder. (it different from Owner listed above) Contractor. 4� —a Address y "Is'. 'a...,. T.,ision.". No n 5, Surely: Address -- ---- state Amount of Bonci; Telephone No.; 6. Lender: Name Address Ctry State Lender's Telephoto No,: 7 Polcons Within the stain Of Florida designated by the owner upon vsiom nollcou or other documents may be served as Provided by Section 713.13(1)(e)(7). Flards Stabiles: Address .City State Telephone Number of Designated Person: 8, In n(I to himself, the owner designates Of to resolve a Copy of the Lionor's Notice as provided In Section 713.13(i)(b), Florida Statutes. Telephone Number of Person or Entity Designated by Owner! 9. Expiration date of Notice of Cornmencernerit(the wtairlition date may not in before,tho Completion of construction and final payrnerit to the contractor. but vAlf be one year from the date of recording artless a different date is sascffied): WAFtN1NG TO OWNER: ANY PAYMENTSMADE BY; MNER'ArTER THE EXPIRATION Of THE NOTICE. OF COMMENCF;f.*,NT Under ponalty of perjury, I declare that I have road the foregoing "011co, ofcomnastriceffion! and that the facts %tatedinarein are true to the best of my knowledge and balst, STATE OF FLORIDA COUNTY OF PASCO Sig of or or Losses, r a or Lessee's Authorized Signal 1, 0 The foregoing instrument was ackn000dge 0 me 87 day of '20WAS as (type of authority. e,g., , oiifco'; trustee. attomoy, In fact) for mam. alI M h-h-V of whom Mwas a d) Inauturrie -1 Personally Knom 0 QB Produced�l on"cabon Notary Signature V Type of Idenlification Produced Name (Print) wpdsialbWnQk*wm"loncement_pcOS3048 APPLICATION FOR WEDGEWOOD ARCH ITECTU RA L/LAN SC PI NG Date Received--ff Application Number_-A�-24----- Before making any alterations, additions, or improvements to the exterior of a residence or lot by repairing, reconstructing, rebuilding, or improving after the house is built or any landscaping alteration, additions or improvements, THE HOMEOWNER MUST SUBMIT AN APPLICATION TO THE ARCH ITECTU RAL/LAN DSCAPI NG COMMITTEE FOR APPROVAL. APPROVED REQUESTS WILL EXPIRE SIX (6) MONTHS AFTER DATE OF State, what you wish to do. Applications are required to meet all current state, county and city requirements. All direct and indirect costs associated with the project are the homeowner's responsibility. Sketch a drawing of your proposal on the back of this application it needed. APPLICANT ----- - - NUMBER le ADDRESS—, —;7- PHONE NUMBER Signature of Applicant 'J, ARCH ITECTURAL/1-ANDSCAPING COMMITTEE APPROVED PROJECT — DATE DENIED PROJECT - DATE COMMIT -TEE CONTACT ASSIGNED TO PROJECT -tom— "­—­-111-­­­­­ Homeowner needs to contact this person when project is completed. Tel. APPROVED COMPLETED PROJECT DATE COMMENTS Signature of inspecting Committee member HARMON IUS--WORKAB LE— NEIGHBOR FRIENDLY BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Yli Fi r 1911 Product Approval USER: Public User b Product Approval Menu > Product or Applicatipn Search > Application List > Application Detail FL # FL10477-R8 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer James Hardie Building Products Address/Phone/Email 10901 Elm Ave Fontana, CA 92337 (909) 641-0498 rathisha.sabaratnam@jhresearchusa.com Authorized Signature Rathisha Sabaratnam rathisha.sabaratnam@jhresearchusa,com Technical Representative Rathisha Sabaratnam Address/Phone/Email 10901 Elm Avenue Fontana, CA 90631 (909) 641-0498 rathisha.sabaratnam@jhresearchusa.com Quality Assurance Representative Rathisha Sabaratnam Address/Phone/Email 10901 Elm Avenue Fontana, CA 92337 (909) 614-0498 rathisha.sabaratnam@jhresearchusa.com Category Panel Walls Subcategory Siding Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the V. Andrew Tan Evaluation Report Florida License PE-81662 Quality Assurance Entity Intertek Testing Services NA, Inc, - QA Entity Quality Assurance Contract Expiration Date 12/31/2023 Validated By John Southard, P.E. I Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By FL10477 R8 COI 2001_:_I�Letter of Indepgndence.pdf Standard Year ASTM C1186 2012 ASTM E330 2014 Sections from the Code Product Approval Method Method 1 Option D Date Submitted 12/14/2020 Date Validated 01/05/2021 Date Pending FBC Approval 01/06/2021 Date Approved 02/09/2021 Summar y ry of Products FL # Model, Number or Name Description 10477.1 Artisan® Lap Siding 5/8 inch thick fiber -cement lap siding with tongue and groove I end joints. Limits of Use Approved for use in HVHZ: Yes 1 Installation Instructions I FL10477 R8 II Artisan-LAP-Install-Instr,12-ft Approved for use outside HVHZ: Yes Verified By: V. Andrew Tan 81662 Impact Resistant- No Created by Independent Third Party: Yes Design Pressure- N/A Evaluation Reports Other: For use in HVHZ install in accordance with Miami Dade FL10477 R8 AE 2001-10.1.2 Artisan Lock Joint Siding County Florida NOA 20-0730,07; For use outside HVHZ install i Analysis_CMQ P�df in accordance with manufacturer's installation instructions. is.p FL10477 R8 AE 2001 10.1 1 Artisan Lap Analysis.pdf FL10477 R8 AE_1001-14,4 NOA Letter of Compliance -Artisan Lap.pff Created by Independent Third Party: Yes i 10477,2 Artisan@ Siding with Lock Joint #tem 5/8 inch thick fiber -cement siding with interlocking horizontal System and vertical joints --------- ....... . . ... .............. . ..................... . .. I Limits of Use Installation Instructions Approved for use in HVHZ: Yes 1 FL10477 R8 II Artisan-Lock-Joint-Install-Instr.pdf Approved for use outside HVHZ: Yes i Verified By: V. Andrew Tan 81662 Impact Resistant, No created by independent Third Party: Yes j Design Pressure: N/A 1 Evaluation Reports Other: For use in HVHZ install in accordance with Miami Dade 1 FL10477 R8 AE 2001-10,1.2 Artisan Lock joint Siding County Florida NOA 20-0730,05; For use outside HVHZ install Analysis CMU.pff in accordance with manufacturer's installation instructions. FL10477 R8 AE 2001-10,1.1 Artisan Lock Joint System Ana ly isp f FL10477 R8 AE 2001-14,2 NOA Letter of Compliance Artisan LJS&Lf Created by Independent Third Party: Yes F-7;7 EEI Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. 2007-2013 State of Florida.:: 2 Copyright Privacy Statement :: Accessibility. Statement :: Refund Statement L _ _ Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487,1395, -Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The smalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: M ON *9 Ed M Credit Card Safe Florida Product Approva'-I ArtisanO Lap Siding I o Artisan Lap Siding fastener types, fastening schedule, and installation shall be in accordance with the Miami -Dade County Florida NOA 20-0730.07. Consult the Artisan Lap product installation instructions on the follow pages for all other installation requirements. For use outside of HVHZ, o Artisan Lap Siding fastener types, fastening schedule, and installation shall be in accordance with CAE Engineering Reports No.:2001-10.1.1. Consult the Artisan Lap product installation instructions on the follow pages for all other installation requirements. aX Z ; ZI"•, Artisan® Lap Siding and Trim IMPORTANT: FAILURE TO FOLLOW JAMES HARDIE WRITTEN INSTALLATON INSTRUCTrONSAND COMPLY'WITHAPPLICABLE BUILDING CODES %4.AYVIOLATE LOCAL LAWS, AFFECT BUILDI'NGENVELOPE PERFORMANCE AND IMAYAFFECT`AIARRANTYCOVERAGE, FAILURE TOCONIPLY` ITHALLHEALTHANDSAFETYREGULATIONSWHENCUTTINGANDINSTALiING THIS PRODUCT MAY RESULT IN PERSONAL INJURY, BEFORE INSTALLATION, CONFIRM YOU ARE USING THE CORRECT HARDIEZONES, PRODUCT INSTRUCTIONS BY VISITING HARDIEZONE.COM OR CALL 1-866-942-7343 (366-9-HARDiE) B n L r? STORAGE E I IStore flat and keep dry and covered priorto installation (fig 1). Installing siding wet or t saturated may result in shrinkage atjoints. Protect edges and corners from breakage. James Hardie is not responsible for damage caused by improper storage and handling of the product HANDLING A When working with Artisan' siding and trim products, carry the product on edge. If only one P (� J t person is carrying the product, hold it in the middle and spread arms apart to better support jj,)t t � the product (fig 2). If two people are carrying the product, hold it near each end and on edge q (fig 3). Do not lift or carry Artisan products flat (fig 4). Figure Figure2 Figure Figure Figure 5 24 in o.c. max 1. Position cutting station so that wind wi I I blow dustaway from user and others in working area. 2. Use one of the following methods: a. Best: Circular saw equipped with aHardieBladea saw blade and attached vacuum dust plywood collection system OSB Shea b. Better: Circular saw equipped with aHardieBlade saw blade and a dust collection feature barrier sis b (e.g. Roam Saw) C.Good: Ci rcularsaw equipped with a HardieBlade saw blade Installa11/Zin off stud tongue foundation — NEVER grind or cut with a power saw indoors. starter stripto and groovejoint — NEVER dry sweep dust; use wet dust suppression or vacuum to collect dust. ensure a consistent plank angle For maximum dust reduction, James Hardie recommends using the "Best" cutting practices. For best performance when cutting with a circularsaw, James Hardie recommends using HardieBlade saw blades. sr, iate -r __...__.I planks and trim, then caulk' NOTE: James Hardie makes no representation orwarranty that use ofa particular cutting As option will assure yourcompliance with applicable laws and safety requirements. Apply caulk in accordance with 0 t, L E" _- T I O N Ifyou are unsure which cutting option is bestforyourjobsite, consulta qualified industrial caulk manufacturers' written by JamesHardie hygienist orsafety professional, or contact you rJames Hardie representative for assistance. application instructions. GENERAL REQUIREMENTS - Artisan siding can be installed over braced wood or steel studs, 20 gauge (33 mils) minimum to 16 gauge (54 mils) maximum, spaced a maximum of 24 in o,c, or directly to minimum 7116 in thick OSB sheathing. See General Fastening Requirements, Irregularities in framing and sheathing can mirror through the finished application. Correct irregularities before installing siding. - Information on installing James Hardie products overnon-nailable substrates (ex: gypsum, foam,etc.) can be located in JH Tech Bulletin 19atwww.jameshardiepros,corn - A water -resistive barrier is required in accordance with local building code requirements. The water -resistive barrier must be appropriately installed with penetration and junction flashing in accordance with local building code requirements. James Hardie will assume no responsibility for water infiltration. HardieWrapO'Weather Barrier, a non -woven non -perforated housewrap, does comply with building code requirements. - All flashing and clearance details in figs. 6-18 MUST be followed when installing James HardieO products. - Adjacent finished grade must slope away from the building in accordance with local building codes - typically a minimum of 6in. in the first 1 Oft. - Do not use Artisan lap siding in fascia or trim applications. - Do not install James Hardie products such that they may remain in contact with standing water, - Artisan lap siding may be installed on flat vertical wall applications only. - DO NOT use stain, oil/alkyd based paint, or powder coating on James Hardie products, - For larger projects, including commercial and multi -family projects, wherethe span of thewall is significantin length, the designerand/or architect should take into consideration the coefficient of thermal expansion and moisture movement of the product in their design. These values can be found in the Technical Bulletin #8 "Expansion Characteristics of James Hardie Siding Products" at www.lameshardiepros,com. - James Hardie Building Products provides installation /wind load information for buildings with a maximum mean roof height of 85 feet. For information on installations above 60 feet, please contact JH technical support. • Artisan lap butt joints are designed to be installed off stud. Do not nail within 2 in. of tongue and groove at end of planks, • James Hardie recommends cutting tongue or groove off when butting into trim boards (fig. 18), -When ending Artisan lap atthe bottom of a windoworatthe topof a wall, a finishing strip similartoa starterstrip maybe necessaryto achieve a properplankangle.Also when cutting Artisan lap around doors, windows, or other horizontal trim applications, an additional starter strip may be necessary to achieve proper plank angle (fig. 7), Figure 6 Figure 7 Figure 8 Figure 9 Roof to Wall Horizontal Flashing Kickout Flashing Slabs, Path, Steps to Siding Figure 10 DecktoWall Figure 15 Drip Edge Figure 11 Ground toSiding Figure 12 Gutter to Siding Figure 13 Sheltered Areas Figure 14 Mortar/Masonry Figure 16 Figure 17 Figure 18 Block Penetration Valley/Shingle Extension Butting to Trim remove tongueor correct groove when method butting trim ART1701 P2/8 07118 Artisan Lap and Beaded Lap siding require atrim thickness nf11/2infor proper aesthetics (fig 21), ~ When installing Artisan" Accent Trim all clearance & flashing details figs 8through 18must befollowed. ~2'1/2inminimum 10ge. finish nails may be used to attach Artisan Accent Trim to wood frame construction. ET&F or equivalent fasteners or screws may be used to attach Artisan Accent Trim to steel frame construction. - Fastening instructions are similarfor all applications. When using finish nails, position nails no closerthan 1/2 in from the edges of thetrimandform||othorfast*namnoo|nnerthan3/4in. Fasteners mumtbonoo|oaerthan1in.frnmanduoftrimand spaced e maximum of 16 in o.c. Ensure trim is adequately fastened, Note: James Hardie recommends installing trim boards sothatseams are not visible from the front facing orstreet curb view (fig.2U). ~ Flashing is required over all horizontal protruding and exposed trim. Figure20 Figure21 1,5 in thick trim Board Pre -built corner Site Built Corners Other areas (e.g. window trim, idth band boards and fasci 4 in I nail every 16 in to attach boardstogether+ 2 nails every 16 in 2 nails every 16 in 2 nails every 16 in each board 6 in I nail every 16 in to attach boards together + 3 nails every 16 in 3 nails every 16 in 3 nails every 16 in each board ;I I For Corners, Band Boards, Windows, and Door Applications: Artisan Accent Trim boards can beinstal|edwithPlatTabsandCorner Tabs, which provide concealed fastening. Only Hard leTrim~Fb$and ComerTabscanb* used with Artisan Accent Trim boards to create a concealed fastening, Fastener spacing will vary based on application. Referto fastanertah|eonpage 5.Refer to specific sections in these instructions for required fastener spacing by application (window, band board, etc,) Step1:Attach F|atTobetuthe backside uf the trim using four(4)18 ga . 1/2 in L x 1 A in W narrow crown corrosion resistant staples, equally spaced in one row, positioned no closer than 1/2 in from trim edges using a pneumatic staple gun, (Figure 22) Step2: Forwood frame construction, attach thetrim tothe building with minimum 2, 6d siding nails fastened thmuQhthe HardieTrimFlatTabs. ET&Forequkmlentfastenem may boused toattach the Flat Tabs tosteel frame construction. Installation ofHardieThmtabs inCoastal Regions: James Hardie equirmutha stainless steel staples &astenesbeused when installing MandieThmTabs incoastal regions. Installation ofHundioThm Tabs over Pressure Treated Lumber: HardieTrim tabs must motomneindirect cuntacwithACQmCApren mativ*-treatedwood. Referto the General Fastening section of this document forfurther information, Figure 22 Min 2 in Fasten 4 staples to the center of the nailing ridge, 1.12 in nrn Fla -4­16 in Cc max Figura23 Fasten HardieTrim Flat Tab to minimum 2, 6d siding nails mRT1701p31807118 When using MandieThmtabs pmhuldoutside corners off the wall: - Attach HardieTrim CornerTabsto the back side of the trim using eight (8) - 18 ga. 1/2 in Lx 1/4 in W narrow crown corrosion resistant staples using a pneumatic stapler. Ensure the HardieTrim CornerTabs are fastened tight and straightto the trim boards. (Figure 24) - Forw4odframe construction, attachthotrim tothehui|ding*ith8dsiding nai|ufantenodthmughthoCom*,Tahu.ET&Forequivalent fasteners maybe used toattach the Corner Tabs bosteel frame construction. (Figure 25) ~ Attach aHandieThmCorner Tab 1infrom each end and every 20ino.o. ~ TIP: Creating a jig for the workstation is recommended to ensure the corners are fastened securely and straight. (Figure27) Figure 25 Figure 20 Figuna27 Corner studs Corner Tabs o.5o*5o _— woamorout Siding nail Corner Tab Artisan Accent Trim boards can also be installed directly to the building (fig.31)around corners using 2-1/2inlong minimum 18ga.galvanized finishing nails every 10inu.o. 2-1/2 in Finish nail For Jig: Fasten 2m,4m Der blocks to a work bench Amwo oustud Accent Trim to the timberl blocks ����&� APPLICATION ���� ��0������ ������� �� ������ �����I����* ""^~,,��" " °~~~~"�""~~., FOR ,~..,~~~~,,�' ~~~~~~~~~ _~ OTHER OPENINGS* Trim the opening prior mthe installation of the siding (Figure 29). FiQuna31 »am'mmntiv« oamp 1wmgap Place aF|atTabatthe end m[each trim board and one tab every 10inOC. Flashing neem to be Do notcaulk tucked under the water between tbe Attach thetrimboards and Flat Tabs around the opening aoshown in mn/swauameranu over --s-IdTina and Figures 29and 3O L__—/ munatrauo. the flashing. Figure 30 Figuna2S Side trim pieces go to Header the window including theside trim pieces. *Follow your window/door manufacturers installation instructions for caulking guidance between window/door trim, ART170/P4/8 07118 Aflashing is required over the trim and MardieTrimFlat Tabs. (Figure 34)Terminate ends of the Band Board into Trim or Siding ormiter cut the edges of the trim at the corners oythe building. Place aMardieThmFlat Tab at the end o[each trim board and one tab every stud atamaximum of1&ino,o,The MerdieThmFlat Tabs should be attached to thetrimin an alternating pattern to the top and bottom of the band board (Figure 3203). Use 16ga. galvanized 2 in long finish nails ioensure proper fastening ifneeded, Figure 32 Fasten 4 staples to the center of the nailing ridge -HardieTrinn Flat Tabs Weather - resistive barrier Figure33 FLUSH Flat and oumorabo Flat and ComerTao Siding nail attaches Donot under Only use staples to fasten tab uothe wall. | drive nails. Flat and Corner Tabs to the trim boards, APPLICATION FRAMING MATERIAL FASTENER FASTENER MAX TAB SPACING TAB IS NAILED INTO (TAB TO FRAMING) (TAB TO ARTISAN ACCENT TRIM) ONCHES ON CENTER) Wood Stud (minimurn G=0.42) One 6d corrosion resistant siding nail installed through center of flange into framing FLAT TAB Four 18 go, X 1/2 in long X 1,14 in wide corrosion resistant crown 16 Minimum APA rated Two4d ring shan�c_orrosionresistant siding nails equallystraced installed 7/16 in OSB through flange inteframing staples, equally spaced in onerow Minimum 20 One No,8X I in long XO.323 in head diameter screw (corrosion resistant) gauge steel installed through flange into framing Wood Stud On each flange, Install one 6d corrosion resistant siding nail through flange into framing (minimum G=0,42) For each piece of trim, install Four 20 CORNERTAB Minimum APA rated Oneachflange, Install two 4d ring shank corrosion resistant siding nails through 18ga.X 1/2 in long X 1/4inwide 7/16 in OSB I flange into framing corrosion resistant crown staples, equally space in two rows Minimum 20 On each flange, Installone No. 8X I in long XO.323 in head diameter screw (corrosio gauge steel resistant) through flange into framing Wind -Borne Debris Region: Additional fasteners maybe necessarywhen installing tabs in a Wind -Borne Debris Region, please call Technical Services Figure 36 JOINT PLACEMENT Artisan Lap and Beaded Lap siding butt joints are designed to be installed off stud. Butt joints must not fall within 4 inches of a stud,(fig. 38). Do not nail within 2 in, of the end of planks. JOINT TREATMENT Install factoryfinished tongue and groove edges together at buttjoi nts using JointFlashing (fig 36) STARTER STRIP Install a 1-1/2 in starter strip to ensure a consistent plank angle (fig 5) FASTENER REQUIREMENTS Figm"mmr BLIND NAILING (required) ` I �ater­resistive barrier Wood Framing -Siding nail (0.88inohankx0.221 in HDx2 1/4in long) Steel Framing -Ribbed Bugle Head screw (No.8-18xO.323 in HD x 1 5/8inlong) GENERAL FASTENING REQUIREMENTS * As required by local building code ZMEM PROPER NAIL PLACEMENT 24 in nailing line stud DONOTUSE NAIL LINE water -resistive AS LAPLINE barrier Buttjoints must not fall within 4 inches of a St 11/4 in min, blind nail overla barrier - Use the nailing line provided on the board for proper nail placement. Faotenersmustbecorroaonesistar¢gaIva nizpd.mstnin|easstee. Boctm-gaIva nizuUare anoepta blebutmay exhibit prom utumoonnoion JamouHordinreoommendntheuneofque||ty.hot-dippodge|vanizednaiIs. JomoaHerdieianot eeponsib|ofor the corrosion muistancmof fasteners. Stainless steel fasteners are recommended when inoto||ingJames Hardie prod uctoneorthe uonen.|argebudianofwater, nrinvery humiddimaioo. Manufacturers of ACQ and CA wood recommend spacer materials orother physical barriers toprevent direct contact ofACOmCA preservative -treated wood and aluminum products. Fasteners used toattach HandieThmTabs \opreservative-treated wood shall beu(hot dipped zinc -coated galvanized steel nrstainless steel and inaccordance to2810 PNEUMATIC FASTENING James Hardie products can be hand nailed mfastenedwith aprieumatichool. Pneumatic fastening iohighly recommended. Set air pressure sothat the fastener is driven snug with the surface of the siding. Aflush mount attachment nnthe pneumatic tool |arecommended. This will help control the depth the nail is driven. If setting the nail depth proves difficult, choose a setting that under drives the nail, (Drive under driven nails snug with a smooth faced hammer - Does not apply for installation to steel framing). - Consult applicable product evaluation or listing for correct fasteners type and placement toachieve specified design wind loads. ~ NOTE: Published wind loads may not boapplicable tuall areas where Local Building Codes have vpocifiojuhadicdonConsult James Hardie Technical Services ifyou are unsure nfapplicable compliance documentation. ~ Drive fasteners perpendicular Losiding and framing. ~ Fastener heads should fit snug against siding (no airspoma>. (fig �A) ~Donot over -drive nail heads urdrive nails atonangle. ~|fnail iocountersunk, fill nail hole and add enail, (fig.B) ~Fmwuodframing, under driven nails should behit flush tuthe plank with a hammer (For steel framing, remove and replace na||). ~NOTE:Whonevorustructural membariopresent, Artisan lap should be fastened with even spacing mthostructural member. The tables allowing d|mcttoO8Bo,plywood should only boused when traditional framing ia not available. ~Donot use aluminum fasteners, staples, orclipped head nails. I —A Countersink, snug DONOT DO NOT CAULKING 8t PAINTING For best results, use anElastomeric Joint Sealant complying with ASTM C920 Grade NS,Oass 25 or highermaLatex Joint Sealant complying with ASTM C834. Cau|Nng/Saalammustboapplied inaccordance with the uaulkinQ/suubnmunufactum/ whtt*ninumxtiona,Note:GomecaulNnQmanufacturersdonot allowkmhng. DO NOT use stain moil/alkyd base paints on James Hardiel� products. Factory -primed James Hardie Products must be painted within 180 days of installation]00%mrylic topcoats are recommended. Do not paintwhen wet. Forapplication rates, referto paint manufacturer'svpeoificationa.8aok+oling is recommended ifthepaint bsprayed. CUT EDGE TREATMENT Caulk, paint mprime all field cut edges, James Hardie touch-up kits are required 0otouch-up Colodquuproducts. �����P���O��������N������8����� ��8����~KK��:���W����� ~~~~~~~~.~~~~~— .~~~~...,~~_.,~`~. ~~~.~__.~~..,~_� TOUCH-UP ~~�~�,.~.,~.~._ ~Care should betaken when handling and cutting James Hardie ColorP|usproducts, During installation, use awet soft cloth ormoft brush to gently wipe off any residue orconstruction dust left onthe product, then rinse with ugarden hose, - Touch upnicks, scrapesand nail heads usingthe ColorPI us Technologytouch-up applicator. Touch-up should be used sparingly. If large areas require touch-up, replace the damaged area with a new piece of siding with ColorPlus Technology. - Laminate sheet must be removed immediately after installation of each course. - Terminate non -factory cut edges into trim where possible, and caulk. Color matched caulks are availablefrom your ColorPlus product dealer. - Treat all other non -factory cut edges using the ColorPlus Technology edge coaters, available from Your ColorPlus product dealer. Note: James Hardie does not warrant the usage of third party touch-up or paints used as touch-up on James Hardie ColorPlus products. When repainting ColorPlus products, James Hardie recommends the following regarding surface preparation and topcoatapplication: ~ Ensure the surface isclean, dry, and free ofany dust, dirt, ormildew. ~ Rephming isnormally not necessary. ~1OOY6acrylic topcoats are recommended. ~DDNOT use stain oroil/alkyd based paints unJames Hardie products. o Applyfinish coat in accordancewith paint man ufactu re rs'written instructions regarding coverage, application methods, and application temperature. - DO NOT caulk nail heads when using ColorPlus products, refer to the ColorPlus touch-up section. CARE Ft MAINTENANCE Recommended maintenance includes, but isnot limited to: - Washing down the exterior surfaces every 6 to 12 months with a garden hose or low pressure water spray to remove dirt and debris.* -Re-applying ofexterior finishoa.^ - Maintaining the exterior envelope and connections includingjoints, penetrations, flash ings, and sealants (caulking)that mayprovidea means ofmoisture entry beyond the exterior cladding, ~ Cleaning out gutters, blocked pipes, and overflows mnrequired. o Pruning back vegetation that is touching the building, Clearance between the siding and shrubs is recommended. - Ensuring required external ground clearances and drainage slopes are maintained. °Refer to your paint manufacturerfor washing and mcoatingrecommendations. ARTI 701p71807n8 High pressure water blast and sandblasting may damage the surface of the fiber cement product. Low pressure water spray, a soft medium bristle (nonmetal) brush is most suitable for cleaning fiber cement products. Acid washing can damage the fiber cement surface and is not recommended. Note: If using a pressure washer, care must be taken to ensure that the water stream does not damage the surface of the siding. Damage to siding arising from improper cleaning or maintenance may not be covered by the James Hardie warranty. Using wide fan tips that are kept a minimum of 6 feet from the wall and at pressures under 1500 psi will minimize the chance of damaging the siding. This coverage chart is meant as a guide. Actual usage is subject to variables such as building design. James Hardie does not assume responsibility for over or under ordering of product. uoverage iii-ea LeSS Upel Lap Width 5114 71/4 81/4 1 SQ = (11 00sq. ft.) Exposure 4 6 7 Note: Number of 12 ft planks, 1 27 18 15 Includes 5% waste factor. 2 53 35 30 79 5 3 45 4 105 70 60 5 132 88 75 6 158 105 90 7 184 123 105 8 210 140 120 9 237 158 135 10 263 175 150 11 289 193 165 12 315 210 180 13 342 228 195 14 368 245 210 15 394 263 225 16 420 280 240 17 447 298 255 18 473 315 270 19 499 333 285 A WARNING :Thisr)to(jijctcariexpos(,,yo€i to chernoalsincluding resk)irablecrystallinesilic,,i,whi{.h is known"othe state of Cilifornia to causecancer. Formoreinformifion go to RECOGNITION: In accordancewith OC-ES EvaluatIon Roper, ESR-2290, Artisan,,'�'Iap is recognize as a suitable alternate to that specified in: the 2006, 2009, 2012 & 20 15 International Residential Codefor One and Two -Family Dwellings, and the 2006, 2009 2012 & 2015 International Building Code, Artisan iari is also recognized for application in the following State of Florida listing Fl-#1 0417, Dade County, Florida NOA No.15-0122.03.02 and T xas Department of Insurance Product Evaluation EC-55. Thesedoew rents shouldalso be consulted fc,,r additional informatio? , concern,ng t; a suitab.lizy of this orocluct for specific appIir,'af0on$' .a M HardieTrim(c-, boards may b.�' Installed as an equal alternative to corrventional trim permitted for use In: 2006, 2009: 2012 & 2015 intimations' Building Code, Section 1403.1, and the 2006, 21009, 2012 & 2015 International Residence Code. for One - and Two - Family - Dwellings, Section R703.11. @ I 2018,lames Hardie Building Products, Inc. All ralits reserved TM, SM and 0 denote trademarks or registered trademarks of James Hardie Technology Limited, ART1 701 P8/8 07/18 Productwarranties, safetyinformation and additional Installation information are available atjameshardiepros.coni Film- :1 ZAMM 0741=1 - MIMMEMMM BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search dProduct Approval b ro USER: Public User Product Approval Monti > Product or Application search > Application List > Application Detail FL # FL39780-Rl Application Type Revision Code Version 2020 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer GAF Address/Phone/Email 1 Campus Drive Parlsppany, NJ 07054 (800) 766-3411 mstieh@gaf.com Authorized Signature Michael Stich mstieh@gaf,corn Technical Representative Michael Stich Address/Phone/Email I Campus Drive Parsippany, NJ 07054 (973) 628-3000 mstieh@gaf.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Product Evaluation Entity Evaluation Entity Miami -Dade BCCO - EVL Quality Assurance Entity Miami -Dade BCCO - CER Quality Assurance Contract Expiration Date 02/21/2027 Validated By Miami -Dade BCCO - VAL Certificate of Independence Referenced Standard and Year (of Standard) Standard Year ASTM D3462 2010 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option C Date Submitted Date Validated Date Pending FBC Approval Date Approved u 01/31/2022 02/07/2022 02/12/2022 FL # Number or Name 39780A ........ ... . ... Timberline HD@, Timberlme@ Natural Shadow@, Timberline NS@, Timberline American@ Harvest@, Timberline AH(§, Timberline@ HDZ­, Timberline CS& and FortitudeTM Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: No Impact Resistant: No Design Pressure. N/A Other. Description ......... . . .... .............. . Fiberglass reinforced asphalt roof shingle with a laminate profile. Installation Instructions FL39780 R1 II 21-1209.01.pjdf Verified By: Miami -Dade BCCO - EVL Created by Independent Third Party: Evaluation Reports FL39780 R1 AE 21-1209.01,p.df !Contact Us :: 2,601 Blair Stone Road Tal a assee FL 32399 Phone: 850-487-182 , The State of Florida is an AA/EEO employer. _QopyLight 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395, -Pursuant to Section 455,275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, ES., please click here . Product Approval Accepts: mWondo MIAMI-DADE COUNTY MIAMI- PRODUCT CONTROL SECTION OEM 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) NvNN-w.mianiidade.2ov/econotiiv UAF I Campus Drive' P-arst nanv.VJ 0705� 0�.,, This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The Z� documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Timberline HD', Timberlineo Natural Shadow®, Timberline® NS, Timberline® American Harvest', Timberline® AH, Timberline HDZO, Timberline® CS and Fortitude® Shingles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA # 19-0312.04 and consists of pages 1 through 6. The submitted documentation was reviewed by Alex Tigera. NOA No.: 21-1209.01 MIAM 1!�ADE COUNTY Expiration Date: 02/21/27= Approval Date: 01/06/22 Page 1 of 6 Category: Roofinc, Sub -Category: Asphalt Shingles Materials: Laminate Deck Type: Wood This approves GAF Timberline HD®, Timberlineo Natural Shadow"', TimberlinOAS, Timberline American® Harvest', Timberline" AH, Timberline HDZ', Timberline' CS and Fortitude' Shingles as manufactured by GAF as described in this Notice of Acceptance. PRODUCT DESCRIPTION Product Dimensions Test Product Description Specifications GAF Timberline RDe 13 '/4" x 39 TAS 110 Fiberglass reinforced heavy weight asphalt roof Manufacturing shingle, with a laminate profile Locations #1, 2, 3, 4, 5, 6, 7 GAF,rimberlineo Natural 13 '/4" x 39 3/8" TAS 110 Fiberglass reinforced heavy weight asphalt roof Shadow' and Timberline' NS shingle, with a laminate profile Manufacturing Locations #1, 2, 3, 4, 5, 6, 7 GAF TimberlineD' American 13 '/4"x 30/8" TAS 110 Fiberglass reinforced heavy weight asphalt roof Harvest° shingle, with a laminate profile Manufacturing Locations #2, 4 , 6 GAF Timberline"' AH 13 '/4" x 39 3/8" TAS 110 Fiberglass reinforced heavy weight asphalt roof Manufacturing shingle, with a laminate profile Locations #2, 4, 6, 9 GAF Timberline HDZ® 13 1/4" x 39 3/8" TAS 110 Fiberglass reinforced heavy weight asphalt roof Manufacturing shingle, with a laminate profile Locations #1, 2, 3, 4, 5, 6, 7, 8, 9, 10 GAF FortitudO' 13 '/4" x 39 3/8" TAS 110 Fiberglass reinforced heavy weight asphalt roof Manufacturing shingle, with a laminate profile Location #4 GAF Timberline'—" CS 13 '/4" x 39 3/8" TAS 110 Fiberglass reinforced heavy weight asphalt roof Manufacturing shingle, with a laminate profile Location #9 NOA No.: 21-1209.01 Expiration Date: 02/21/27 Approval Date: 01/06/22 Page 2 of 6 MANUFACTURING LOCATION 1. Tampa, FL 2. Michigan City, IN 3. Baltimore, MD 4. Myerstown, PA 5. Ennis, TX 6. Tuscaloosa, AL 7. Dallas, TX 8. Shafter, CA 9. Fontana, CA 10. Minneapolis, MN Test Agency Test Identifier Test Name/Report Date Underwriters Laboratories, LLC ASTM D3462 4788932264 1.2/13/19 ASTM D3462 4788717529 01/31/19 ASTM D3462 4787344101 07/25/16 TAS 107 4789225984 I1/l/19 TAS 107 4788717529 01/31/19 TAS 107 OINK45803 04/13/94 TAS 107 06NK05159 08/09/06 TAS 107 04NK04273 02/20/04 TAS 107 05CA42840 1.1111105 TAS 107 02NK41811 11 / 11 /02 TAS 107 03CA35209 10/17/03 TAS 107 04CA13850 08/30/04 PRI Asphalt Technologies, Inc. TAS 100 GAF-912-02-01 12/17/18 TAS 100 GAF-044-02-01 01/13/04 TAS 100 GAF-098-02-01 11/08/05 TAS 100 GAF-101-02-01 11 /09/05 TAS 100 GAF-116-02-02 03/23/06 TAS-100 ELK-083-02-01 10/ 16/02 ELK-084-02-01 10/15/02 ELK-085-02-01 10/14/02 ELK-086-02-01 10/24/02 ELK-087-02-01 10/21 /02 ELK-088-02-01 10/16/02 ELK-107-02-01 10/09/03 ELK-108-02-01 10/09/03 ELK-109-02-01 10/09/03 NOA No.: 21-1209.01 MIAP91•C?ADECOUNTY Expiration ]Date: 02/21/27 Approval Date: 01/06/22 Page 3 of 6 LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product, 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. INSTALLATION 1. Shingles shall be installed in compliance with Roofing Application Standard RAS It 5. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail'A', attached. 5. Nailing shall be in compliance with Detail U, attached. Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility, and following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. 1. Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to property evaluate the installation of this system. NOA No.: 21-1209.01 Expiration Date: 02/21/27 Approval Date: 01/06/22 Page 4 of 6 DETAIL A COURSE LAYOUT NOA No.: 21-1209.01 Expiration Date: 02/21/27 Approval Date: 01/06/22 Page 5 of 6 OVERALL DIMENSIONS AND NAILING PATTERN FOR GAF TIMBERLINE HD"�'TimBERLINENATURAL SIIADOW' AND TFBERLINE0 39-3/811 - 14-112" - 17-1/2" (3M - 445mm) 6-112- - 9-1/2" (1 66 - 241 Y12 2-TE 14-1/2" - 17-1/2" 368-4 4 5rnm) 6-1/2" - 9-1/2" ENHANCED NAILING PATTERN - six nails per shingle* required by some local codes and required for enhanced wind coverage on certain products, See limited warranty for details. Nail guide line 5-34'- 6-1/4" (146mm - 159mm) from bottom of shingle Self seal adhesive on back OVERALL DIMENSIONS AND NAILING PATTERN FOR TIMBERLINE HDZO, TIMBERLINEO CS, TIMBERLINEAH, AND FORTITUDE"�' 6-1,12'- 91Z (165 rum -241 T . 11T - 2-t,72' (13 rpun - 64 mm) 13-1/4' (337 mm) 5-1 3,116 -6-1 4" 48 mm -1 -59 111m) For Mansard Roots 39-3/8" (1 m) 1/2' - 2--V2-' (13 mm - 64 -® TARGET NAIL ZONE 5-13116'- 7-5' 18' (148 mm - 194 mm) NOA No.: 21-1209.01 �MIJAMIOADE:j�CQUNTY a Expiration Date: 02/21/27 Mffiffl Approval Date: 01/06/22 Page 6 of 6 Florida Building Code Online Page 1 of 2 Comments Archived Ej Product Manufacturer Custom Window Systems Inc. Address/Phone/Email 1900 SW 44th Avenue Ocala, FL 34474 (352)368-6922 Ext291 jlathrop@cws.cc Authorized Signature Jay Lathrop jlathrop@cws.cc Technical Representative Jay Lathrop Address/Phone/Email 1900 SW 44th Ave Ocala, FL 34474 (352)368-6922 Ext291 jlathrop@cws.cc Quality Assurance Representative Jay Lathrop Address/Phone/Email 1900 SW 44th Ave. Ocala, FL 34474 (352)368-6922 Ext291 jlathrop@cws.cc Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer __ Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Lucas A. Turner the Evaluation Report Florida License PE-58201 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 07/21/2028 Validated By Steven M. Urich, PE CI Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By FL161 R7 COI EvalReport176G. Standard ASTM E283 ASTM E330 ASTM E331 Year 2004 2002 2009 Sections from the Code f 7 _ /l /l l T_ - __. /T---TAT 9 / A - 1 /T 1 /T 1T /T'9rs-- - 9 , 1 11 1 /n !a /'e 9 Florida Building Code Online Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 08/27/2020 08/30/2020 09/18/2020 12/15/2020 FL At Model, (dumber or Name Description 161.1 Guardian Hinged Door Guardian Hinged Door w/Glazed Insert. Limits of Use Installation Instructions Approved for use in HVHZ: No FL161 R7 II CWS-176G.Ddf Approved for use outside HVHZ: Yes Verified By: Lucas A. Turner 58201 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +40/-40 Evaluation Reports Other: Not for use in HVHZ. Primarily used with Screen FL161 R7 AE EvalReDort176G,odf Rooms. Created by Independent Third Party: Yes 161.2 Guardian Hinged Door Guardian Hinged Door w/Solid Core. Limits of Use Installation Instructions Approved for use in HVHZ: No FL161 R7 II CWS-242F.Ddf Approved for use outside HVHZ: Yes Verified By: Lucas A. Turner 58201 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +40/-40 Evaluation Reports Other: Not for use in HVHZ. Primarily used with Screen FL161 R7 AE EvaIReport242F.Ddf Rooms. Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road Tallahassee FL 32399 Phone; 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850,487,1395. *Pursuant to Section 455.275 (1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: vga <, ,; WN 99 M Credit Card Safe file:///C:/TJsers/FBCPF,R-1 /AnnData/T,deal/Temn/T,nw/T7ZCOFMC_htm 5/1 1/7.0?.1 TABLE OF CONTENTS GENERAL NOTES & ELEVATIONS........1 CONFIGURATIONS ................................2 SECTION VIEWS ................ - ............... 3 BOM & EXTRUSIONS ..............................4 ANCHOR SCHEDULE & NOTES ............. 5 INSTALLATION DETAILS................ ...... 6 PRIME DOOR - NON -IMPACT (SHOWN WALUM. SINGLE HUNG) 37 1/4" ---1 OVERALL WIDTH MAX. UNIT SIZE GENERAL NOTES 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE FLORIDA BUILDING CODE (FBC), CURRENT EDITION, 2. GLAZING OPTIONS: (SEE SHEET 2) 3. CONFIGURATIONS: OUTSWING, LEFT OR RIGHT HINGED. 4. DESIGN PRESSURE RATING: -NEGATIVE DESIGN LOADS BASED ON, TESTED PRESSURE AND GLASS TABLES ASTM E-1300-04e01/09. -POSITIVE DESIGN LOADS BASED ON, TESTED PRESSURE, WATER INFILTRATION TEST PRESSURE AND GLASS TABLES ASTM E-1300-04e01/09. 5, ANCHORAGE: f HE 33 1/3% STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT. SEE SHEET 6 FOR ANCHOR DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 6. NOT APPROVED FOR IMPACT RESISTANCE. IMPACT PROTECTIVE ;TYP.) SYSTEM IS REQUIRED IN WIND BORNE DEBRIS REGION. 7. ALL FRAMES SCREWED TOGETHER. SMALL JOINT SEAM SEALANT USED AT ALL FRAME JOINTS. Lucas Turner 2020.08.21 11:22:35 -05'00' WINDOW SYSTEMS E 1900 SW 44TH AVE. OCALA, FLORIDA 34474 www.Cws'cc I I A * UffiezI MO # WN' MINC kq a I kyl I —Z < I— owo <O)w 0 b . w 2 ,� w � >- 0 W LL I- w Z i-- �:E 0 Z OZl-0T 2 < Q w 0 0 U ow-Z6a-"T' 'o� 0 Z Z-� Z 0 Dw < —ZooZ2!'0_ �- — LL:E 0 0 LL CZ) < w M 0 a� 2 Z w 0 U) Ww U) LU 0 � U) 0� 0 �� 0 w 0 CL a: > cc maww ui H 8/18/2020 LUCAS A. TURNER, P.E. FL PE # 58201 2428 Old Natchez Trcjrl Camden, TIN 3832' PH, 941-380-1574 GENERAL NOTES AND ELEVATIONS AIDE 09/08/08 TG _# _REV.: CWS-176 G ALE: SHEET 1:15 1 OF WINDOW SYSTEMS 1900 SW 44TH AVE. ' OCALA, FLORIDA 34474 WWW.CWS.CC 27 3/4" MAX UNIT WIDTH 1000 ALUM. 23 1/2" GLASS DLO GUARDIAN DOOR NON -IMPACT z ¢z EELA a o0 z w zoz �-z O OI- OLja=If= 2612" U o ULt-z PU)a- z-� z n GLASS DLO z ¢ O- P:: 00=z ��4Qy>0wp=O— ppl-7> 57" / I-- -�3:0 Lij ll MAX CG d z� OJu�) =a =OL n UNtT x w ud w a> HEIGHT a ° D. 1`�yb11t9Stit/tlli GLASS GLASS DLO No. 58201 �j -0 STATE OF ai�g 8/1812020 22" LUCAS A. TURNER, P.E. GLASS DLO FL PE # 58201 2428 Old Natchez Trc Trl SH-3500 (SEE SEPARATE APPROVAL) Camden, TN 38320 ALL GLAZING DSS TEMPERED MIN. PH. 941-380-1574 SHEET DESCRlPTON: DOOR CONFIGURATIONS DRAWN BY: DATE'. AIDE 09/08/08 DWG#: CWS-176 G SCALE: SHEET 1:10 2 OF 6 15 12 WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA, FLORIDA 34474 INTERIOR gwww.CWs.CC 13 r 1000 ALUM. 0E] GUARDIAN DOOR El NON -IMPACT 37 14 3 14 28 29 10 3 Z w Z I-- �:'5 Zx:5<wwb0 0 a-Frnd SECTION VIEW B-B 0 1- 0 0 LL > cc 0 Zw w uj U) w J U) a- a- 0 cr� 0 �� w 0 n- T , > T Lu:'�: Lu 11) aw CIS A- I'tj�// ri No, 58201 19 STATE rri Ott 8/18/2020 16 7 LUCAS A. TURNER, P.E. FL RE # 58201 5 2428 Old Natchez Trc Tri -T Camden, TN 38320 PH. 941-380-1574 -SHEET -DESCRIPTION 23 SECTION VIEWS 6 (1193) ALT. THRESHOLD (1186) ALT. THRESHOLD (1126) THRESHOLD DESCRIPTION MAX. POS.DP DRAWN _BY DATE SECTION VIEW A -A 1126 BUMPER THRESHOLD NONE AIDE 09/08/08 1186 STANDARD THRESHOLD 140 DWG #: REV, 11_93 SADDLE THRESHOLD NONE ITEMS NOT SHOWN FOR CLARITY: NOTE: INSTALLATION w/1 126 OR 1193 THRESHOLDS ONLY ALLOWED CWS-176 _sZ_ALE G 1:2 __SHEET 9, 11, 17-19, 24-26, 31, 36 WHERE NO WATER INFILTRATION RESISTANCE IS NEEDED. 3 OF 6 OUTSWING 3 1 S-1374 IJAMB, Z BAR, OUTSWING ALUM 5 S-1186 THRESHOLD ALUM 6 S-1193 SADDLE THRESHOLD ALUM 7 S-1126 BUMPER THRESHOLD ALUM 8 H-1001 DOOR CORE ALUM 9 S-1002 CORNER KEY ALUM 10 P-3008 HINGES SS 11 P-3376 POP RIVET ss 12 P-3280 DEADBOLT - 3127-A-Q SS 13 P-3280 LOCKSET - 3127-A-Q SS 14 P-3302 WSTP, .330 x .187 FIN, BLACK SOFT TOUCH 15 P-3310 WSTP, .350 x .187 BULB VINYL 16 P-3224 WSTP., THRESHOLD VINYL 17 P-3087 GASKET, DOOR KNOB FOAM 18 P-3204 GASKET, DEADBOLT FOAM 19 P-3584 FOAM CORE 23 P-3214,BUGSWEEP 24 P-3539 8 x 3/4, QUAD PAN TEK STEEL 25 P-3329 FOAM BLOCK, DOORKNOB FOAM 26— P-3350 FOAM BLOCK, FILLER DOOR PLUNGER SS 29 P-3370 I CYLINDER. DEAD BOLT ss 6 CORNER KEY - S-1 002 4 DOOR CORE - H-1001 36 OUTER FRAME ASSEMBLY 11 PANEL FRAME ASSEMBLY 32 P-3214 IBUGSWEEP PLASTIC 2 3/8" 33 5-IWO ADJUSTABLE SWEEP ALUM 2 3/8' 2 5/8' 34 '�'R STRIKE SS —7 35 P-3368 I DEADBOLT STRIKE SS [Z3/4' 3/4" —3-6 P-3612 18 x 1-1/4 QUAD PAN W/ 114" LEAD STEEL III--L SX --L 1 13/16" 1/16" 5L 1 37 P-3776 IBACKER PLATE 33 1 1 1/16" 6; LINE ITEMS NOT USED: I I ADJUSTABLE SWEEP S-1300 OUTSWING HEAD S-1377 OUTSWING JAMB S-1 374 NOTE: SINGLE HUNG B.O.M. NOT SHOWN, SEE SEPARATE APPROVAL. 2 15/16" LE-1-1 5 1 1/2" L(w—wF 1/16" STANDARD THRESHOLD S-1 186 NOTE: ALL ALUMINUM EXTRUSIONS ARE 6063-T6 UNLESS OTHERWISE NOTED. A--� BUMPER THRESHOLD S-1 126 3 7/16" T- 13/ 16" SADDLE THRESHOLD S-1 193 THRESHOLD DESCRIPTION MAX. POS. DP 1126 BUMPER THRESHOLD NONE WINDOW SYSTEMS L 1900 SW 44TH AVE. OCALA, FLORIDA 34474 www.Cws.CC MuTIT11ma1l a A. TU%, No. 58201 STATE OF 8/18/2020 LUCAS A. TURNER, P.E. FL RE # 58201 2428 Old Natchez Trc TrI Camden, TN 38320 PH. 941-380-1574 BOM AND EXTRUSIONS AIDE DWG# CWS-176 NOTE: INSTALLATION w11 126 OR 1193 THRESHOLDS ONLY ALLOWED -S—CALE. WHERE NO WATER INFILTRATION RESISTANCE IS NEEDED. 1:2 09/08/08 G SHEET 4 OF 6 12 3/4" MA> 6" MAX. (Tl 6" MAX. (T`r 17" MAX. O.C. (TYP.) INSTALL ONE #8 ANCHOR THRU EACH HINGE INTO SUBSTRATE (TYP, ucsr0 ANCHOR LAYOUT ,IOTE 2 JSTALLATION NCHOR(TYP.) INSTALL TWO #8 ANCHORS THRU STRIKE PLATE AND DEADBOLT STRIKE PLATE INTO SUBSTRATE(TYP.) 1. INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION. SILL ANCHOR SPACING SAME AS HEAD. 2. SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX. ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16" IS PRESENT. LOAD BEARING SHIMS SHALL BECONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. WOOD SHIMS ARE NOT ALLOWED. 3. ANCHOR TYPE, SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS, SEE TABLE 1, SHEET 6. 4. ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING, DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST BE PROTECTED TO PREVENT REACTION, 5. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM SPECIFIED IN TABLE 1. SHEET 6. 6. ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. 7. A MINIMUM CENTER -TO -CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS: 3" FOR MASONTRY, 1" FOR WOOD AND METAL. 8. WOOD OR MASONRY OPENINGS, BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLE1, SHEET 6. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED, 9. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: FMA/AAMA 100(FIN WINDOWS), FMA/AAMA 200(FLANGE WINDOWS), FMAPWDMA 250(BOX WINDOWS), FMA/AAMAPWDMA 300(EXTERIOR DOORS) WINDOW SYSTEMS lS 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC Z � ¢z3: t- ow0 Cojw--oo w ZZZ �CZIw o- O 0---06<T,X Uwt-zn ��a d Off,, -K DW U� U ¢ d ow 0 jJ O U) w w0 0 w CL 0 w O a iO> Ziw� 2 n No. 58201 STATE OF L'Izo tX 8/18/2020 LUCAS A. TURNER, P.E. FL PE # 58201 2428 Old Natchez Trc Td Camden, TN 38320 PH.941-380-1574 ANCHOR SCHEDULE AND NOTES AIDE 09/08/08 JG #: REV,; CWS-176 G TLE; SHEET 1:20 5 OF 6 TYPICAL HEAD ANCHORAGE MIN. EMBEDMENT SEE TABLE 1 SUBSTRATE BY OTt SEE TABLE 1 PERIMETER SEALAI BYINSTALLER INSTALLATION ANC SEE TABLE 1 SEALANT BEHIND FLANGE BY INSTAL MIN. EDGE DIST. SEE TABLE 1 4" MAX. SHIM INTERIOR INSTALLATION ANCHOR SEE TABLE 1 SEAL OR SET IN CONCRETE OR MASONRY PERIMETER SEALANT BYINSTALLER qi n 6 MIN. EMBEDMENT SUBSTRATE BY OTHERS -I ( SEE TABLE ? SEE TABLE 1 I MIN. EDGE DIST. SEE TABLE 1 A VERTICAL SECTION 6 TYPICAL SILL ANCHORAGE_ TABLE I: APPROVED INSTALLATION FASTENERS SUBSTRATE TYPE ANCHOR TYPE MIN. EMBEDMENT MIN. EDGE DIST. CONCRETE (2.0 KSI MIN.) 3/16" ITN TAPCON 1" 1-1/8" CONCRETE (2.85 KSI MIN.) 3116" ELCO ULTRACON T. 1" 2XMIN. SOUTHERN PINE (G=0.55) #10 WOOD SCREW 1-318" 1/2" 0.045" ALUM. (6063-T5 MIN.) OR 0.045" STEEL (33 KSI MIN.) #10 GRADE 5 SELF -TAPPING ( DRILLING SCREW FULL THREAD THRU 0.045" 1/2" HINGE AND STRIKE PLATE ANCHORS 2XMIN. SOUTHERN PINE (G=0.55) #8 WOOD SCREW 1-318"' 7/8" MIN. EDGE DIST. SEE TABLE 1 NTERIOR 1/4" MAX. SHIM HINGE/STRIKEPLATE HINGE/STRIKEPLATE VN1hHD47V1/ SYSTEMS S�—J 1900SW 44THAVE. OCALA, FLORIDA 34474 WWW.CWS.CC -- 1000 AI -UM. MIN. EMBEDMENT MIN. EDGE DISTANCE GUARDIAN DOOR SEE TABLE 1 SEE TABLE 1 NON -IMPACT MIN. EMBEDMENT ¢ z Q z O HINGE/STRIKE PLATE SCREW SEE TABLE 1 z o w O Q- a w�a SEE TABLE 1 w o. U- zpz t-Z� qtn_ Pw�zt-�2= z z=2Q�wp0 INSTALLATION ANCHOR SUBSTRATE BY OTHERS 0 00 U j d p S- SEE TABLE 1 SEE TABLE 1 o z- z z r 1) cc SEALANT BEHIND PERIMETER SEALANT z ¢ 2z i6��— 1-- , 2 O p "- z FLANGE BYINSTALLER BYINSTALLER < 2 O � O _ Cr��Or�w ( B HORIZONTAL SECTION � oioww z w O cn � ccuj 6 TYPICAL JAMB ANCHORAGE w0 w H 0 a-= 2 na. ­- a� a � Na. 58201 r6 STATE OF 8/18/2020 LUCAS A. TURNER, P.E. FL PE # 58201 2428 Old Natchez Trc Tri Camden, TN 38320 PH,941-380-1574 INSTALLATION DETAILS DRAWN BY: DATE: ADE 09/08/08 DWG#: REV.: NOTE: GLAZED WINDOW FRAME ATTACHMENT SHALL FOLLOW ALUMINUM CWS-176 G ANCHORAGE AS SHOWN IN TABLE 1. SCALE : SHEET 1:2 6OF6 Florida Building Code Online Page I of 2 Comments Archived Product Manufacturer Custom Window Systems Inc. Address/Phone/Email 1900 SW 44th Avenue Ocala, FL 34474 (352) 368-6922 Ext 291 jlathrop@cws.cc Authorized Signature Jay Lathrop jlathrop@cws.cc Technical Representative Jay Lathrop Address/Phone/Email 1900 SW 44th Ave Ocala, FL 34474 (352) 368-6922 Ext 291 jlathrop@cws.cc Quality Assurance Representative Jay Lathrop Address/Phone/Email 1900 SW 44th Ave. Ocala, FL 34474 (352) 368-6922 Ext 291 jlathrop@cws.cc Category Windows Subcategory Single Hung Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer '-� Evaluation Report - Harccopy Received Florida Engineer or Architect Name who developed Lucas A. Turner the Evaluation Report Florida License PE-58201 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 07/21/2028 Validated By Steven M. Urich, PE dl Validation Checklist - Hardcopy Received Certificate of Independence fLjZaZZ_E6COI lReport109-.Rdf Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Standard AAMA/WDMA/CSA 101/LS.2/A440 year 2011 I .. I / I - I 1 -I I - / / I , I - - -1 - I - I - I I - - 1- 1 1 1 1 1 1 . I- I I I Florida Building Code Online Page 2 of 2 Product Approval Method Method 1 Option D Date Submitted 08/24/2020 Date Validated 09/14/2020 Date Pending FBC Approval 09/15/2020 Date Approved 12/15/2020 Summary of Products I I FL # Model, Number or Name Description 17822,1 SH-610 Vinyl Single Hung, Non- Max. size 53 1/8" x 76", Fin, Flange, DP 35 PSF, Glass Impact complies with ASTM E1300. Limits of Use Installation Instructions Approved for use in HVHZ: No FL17822 R6 II CAS-1099D.pdf Approved for use outside HVHZ: Yes Verified By: Lucas Turner, PE FL PE 58201 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +35/-35 Evaluation Reports Other: FL17822 P6 AE EvalRenortI099D,odf Created by Independent Third Party: Yes Back Ka Contact U :: 2601 Blair Stone _Road _.Tallahassee _FL 3239_9 fborte. 850-487-L _18 4 The State of Florida is an AA/EEO employer. Copyright 2007:2013 State of Florida.:: Privacy Statement :: Accessibility Statement Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455,275 (1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails, provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: MMMERM M63rom httn,-,://www-florl dabi ii] din P - nrp/-nr/nr ann dtl-,g,-,nx?nnram=wCTFVXOwtT)nt?ZO-K6B?YITT 1/4/?O?1 SINGLE HUNG — NON —IMPACT (SHOWN WIDIFFERENT OPTIONS) S 3 FLANGE WIDTH 53 i/8" MAX UNIT WIDTH GLASS PLO A I i!4' V4GE IGI T p i C f I ]6' MAX UNIT HEIGHT / I I I I I I A MXSASH HEIGHT 4. I I 4 X D ' I I I it TABLE OF CONTENTS GENERAL NOTES& ELEVATIONS.....1 GLAZING DETAILS.. .............................2 SECTION VIEWS..........................._.....3 EXTRUSIONS & B.O,M...................._...4 ANCHOR SCHEDULE & NOTES__.....5 INSTALLATION DETAILS..................6-7 i C I A 47' GLASS DLO 49 i6)16' MAX. SASH WIDTH I B 34 b/16' GLASS DLO --s 8 6 6 D 6 F 34 7 GLASSSDLO i I GENERAL NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE FLORIDA BUILDING CODE (FBC), CURRENT EDITION- 2. GLAZING OPTIONS: (SEE SHEET 2) 3. CONFIGURATIONS: "O/X". 4. DESIGN PRESSURE RATING: -NEGATIVE DESIGN LOADS BASED ON, TESTED PRESSURE AND GLASS TABLES ASTM E-1300-04e01/09. -POSITIVE DESIGN LOADS BASED ON, TESTED PRESSURE, WATER INFILTRATION TEST PRESSURE AND GLASS TABLES ASTM E-1300-Q4e01/09. 5, ANCHORAGE: THE 33 113% STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT. SEE SHEETS 6-7 FOR ANCHOR DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS, 6. NOT APPROVED FOR IMPACT RESISTANCE. IMPACT PROTECTIVE SYSTEM IS REQUIRED IN WIND BORNE DEBRIS REGION, 7. ALL FRAMES AND VENTS FULLY WELDED. SMALL JOINT SEAM SEALANT USED AT FIXED MEETING RAIL AND JAMB. 8. SERIES / MODEL DESIGNATION SH-610. 9. THE DESIGNATION X AND O STAND FOR THE FOLLOWING: X = OPERABLE SASH, O = FIXED SASH 111 SECTION CALLOUTS APPLY TO ALL ELEVATIONS IN A SIMILAR LOCATION. 11. EXTERNAL WEEP SLOT = 114 x 1-1/2" LOCATED 5" FROM BOTH ENDS, Lucas Turner 2020.08.21 09:58:09 -05'00' MAX. UNIT rSIZE DESIGN PRESSURE RATING IMPACT RATING 53-118" x 76" +(- 35 PSF NONE 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWSOC z 3 ¢zQ Z OWO w ao W 20Z CL�ZH Z Zxi¢pp O ONOLj LinH O O��z Z=Um r Q3pwQ�pz Z w 20wo0wQw n4 0_1 0 w'c wxa_xwN a`,`XyJAi�I!!I!!t! :mot No. $8201 � STATE OF d "xoaor r yfjd !1 NA411��X��+, 8/1 M020 LUCAS A. TURNER, P.E. FL PE # 58201 2428 ON Natchez Trc Ti Camden, TN 38320 PH. 941-380-1574 HEET DESCRIPTION. GENERAL NOTES AND ELEVATIONS PAWN BY: DATE: EMK 06/19115 WGd: REV.: CWS-1099 D CALF: SHEET 1:15_.. 1 OF. 7.. _. NISOW SY$7EMS 1900 SW 44TH AVE. OCALA, FLORIDA34474 www,cws,cc 610 PVC SINGLE HUNG NON -IMPACT 718" OVERALL 7/8' OVERALL 718" OVERALL 7/8' OVERALL < 'z 7 0 u 0 z< I- 0 _z Z' < Z 0 ' "o ' Z z0z X ­§� . § , 0 x Id-�z . z ­ 3t z x d' <woo Z Z _ n 0 Z — n 0 p- i 2 z 0 0 < w 0— o; a- —.w w 1/8' ANNEALED --5/8" AIRSPACE —118' ANNEALED f—QUANEXDQRASEALor, CARDINALX EDGE., RODS ACE 4SG TPS I.G.SPACER 46 SIKAFLEX 552 OR 1URIE-GLAZEW StS' GI -ASS SITE IIW TEMPERED 518' AIRSPACE —118' TEMPERED f—QUANEX DURASEAL., CARDINAL XL EDGE or, KODISPACE 48G TPS I.G.SPACER SIKAILEX 112 OR n4S PURFECT GLAZE 518' GLASS SITE 3116' ANNEALED — I/T AIR SPACE —3116' ANNEALED QUANEX OURASEAL or, CARDINAL M_ EDGECARDINAL KODISPACE 4SG TPS I.G. SPACER SIKAFLEX 552 OR 46 PURE ECT GLAZE 'H' CLASS ITS —3116' TEMPERED — 1/2' AIRSPACE —3116* TEMPERED f— QUANEX DURASEAL or, XL EDGE or KODISPACE 48G TPsl I.G. SPACER PUR11CT G E 'H' 518' GLASS SITE 19 o.58201 GLASS TYPE A GLASS TYPE B GLASS TYPE C GLASS TYPED 8/1812020 LUCAS A. TURNER, P.E. FL PE # 58201 2428 Old N.L,h- TP, Trl C.ordl,P, TN 38320 PH. 941-380-1574 SHEET DESCRIPTION: GLAZING DETAILS DRAWN 8y WATE: EMK 06/19/15 t SETTING BLOCKS PER FBC 2411,3.3.11 CWS-1099 D CArA SHEET 2 OF 7 INTERIOR 13 or 42 WINDOW SYSTEMS LLB 1900 SW 44TH AVE. 44 14 4 1 9 32 44 OCALA, FLORIDA 34474 WWW CWs.CC 34 610 PVC SINGLE HUNG NON -IMPACT UMtS z z 20? x- iz <0 36 z 37 10 1 . § E, 10 3w; o 9'X86<�<TU SECTION B-B 0 0 NOTE LEFT SIDE SHOWS FIXED SECTION VIEW, z 0 cz ' u. RIGHT SIDE SHOWS SASH SECTION VIEW. li - w�!� 2 m X 2 � 0 < O�Cfwo w 27 6 3 mw 0 0, l-, 0 w10 E It W=:E . V�. I INTERIOR ri!79ulll 45 Tu 7 43 ri N 32 58201 Au- ii 01 S z TA AL H F 31 8/1812020 17 i 10 32 32 LUCAS A. TURNER, P.E. SECTION D-D FL PE # 58201 ALT 562 POCKET UNI-FRAME 2428 Old Natchez Tpo TrI C—IBB, TN 33320 4,1 3 PH, 941-380-1574 25 S SHEET DESCRIPTION SECTION VIEWS SECTION A -A SECTION C-C NOTES: ­WN BY: DATE ALTERNATE MEETING RAIL FIN FRAME AVAILABLE FOR BOTH UNI-FRAME EMK 06119/15 AND SLOPE SILL -FRAME AND STANDARD FRAME TYPES. DwG' PRY. 880 BALANCERS AND DEEP POCKET UNI-FRAME CWS-1099 D (H-6193) REQUIRED FOR LARGER SASHES. SHEET NOTE ITEMS NOT SHOWN FOR CLARITY: 38-41 1:2 3 OF 7 ITEM T PART DESCRIPTION MATERIAL 3 71W lir ----------- FRAME CORNER CONSTRUCTION (L-�UZW I H-6125 --LvC 16' 2 H-6125 �IAMIII, OUTEIFIAMI PVC WINDOW SMEMS EVE 1900 SW 44TH AVE- H-6132 SASH SIDE RAIL ED, '21116* 2 318' tqO .. OCALA, FLORIDA 3"74 WWW.CWs'cC 5 H-6136 ISASH BOTTOM RAIL ---EV—C L HEINE. SRHD 6 H-6137 FIXED MEETI p 006 1 AIL EVE NG RAIL. --LV—C 3 9116' 3 718' 7 H-6 OF I CORNER WELD (ALL SIDES) 610 PVC 38 SASH 0 8 S-6141-tGAWITNOPBREAD PVC 114 9 5-6142 SASH STOPPVC SINGLE HUNG NON -IMPACT WSTP, LONBULB VINYL PVC FRAME HEAD & JAMB WSTP, QLON BULB VINYL H-6125 PVC FRAME SILL H-61 26 INTERLOCK < 13 BALANCERS - CONSTANT FORCE RT 562 NYLON 51 S-2001 '� � z S116 -14 P-5392 SASH TILT LATCH C-' NYLON -z MEETIN —1-5 75393 PIVOTCARRIER SCREEN ADAPTOR PVC L -T6 -5396 PIVOT BAR Ss I D �1'p' z Q RAIL C) — _73515 lo SCREWED TOGETHER WITH #8�58PHILFLATWHITESMS STEEL I G u .', . 177 .074' UTERFRAM, z-�-'zQ 18 P-4146 PVC GLAZING BEAD i:a oo'�-Du 19 P'5615 S_61 PVC SASH STOP PVC SCREEN ADAPTOR < Fz SETTING BLOCK RUBBER 41 3-6138 S-6143 0 20 5,2001 INTERLOCK RAIL ALUM < z 21 1 S-2006 REINF, SASH SIDE RAIL. HD ALUM 2 ia 2 118— 00. 22 5,2007 R§ OM RAIL 71_� REINF, BOTTOM —AL—um 2' .; I OR wo i W-. 23 5-2008 R N FMR . . ..... ............ ..... ALUM C T'O jl� I T 1 5 24 S-2009 REINF TOP _RAIL ALUM 7116 1 26 P-5388 LOCKS NYLON 1116, 27 _5389 KEEPERS NYLON 28 P-4779 WEEP COVER _NYLON PVC SIDE RAIL PVC SASH STM RAIL PVC SASH FMR PVC SASH TOP RAIL 31 LIKA FLEX SS2 OR PU�FECT GLAZE I-P SIUCONE H-6132 H_6136 H-6137 H-6138 32 P-330S WSTP., .270X 187,SOFTTOUCH FIN P�".S 33 P,5425_��ITI,,IOIXII�"XII�"IISTPWG 34 HOLE' NYLON 35 GLASS LEESHEET2 36— P 4-638 STEEL "ATF DIF A-� 37 P-3218 SCREEN FRAME ALUMPVC SCREEN RETAINER 38 P-4754 SCREEN CORNER KEY --NYLON REINF. BTM RAIL REINF. FMR REINF. TOP RAIL S_62 1 7 39 F-322 8 SCREEN SPLINE S-2007 S-2008 S-2009 jO P-3029 SCREEN LIFTS 3 7116' 41 P-3033 SCREEN SPRINGS 8/1812020 43 H-6157 HD FIXED MEETING RAIL 44 44 H- 1 UNI-FRAME 880 BALANCERS 2 1/16' E, 2118, LUCAS A. TURNER, P.E. 42 BALANCERS- CONSTANTFORCE RT 880 3t1 PV PVC 45 H-21Y5 REINF HD FMR AALUCM -111 �713/1s•� 13116, FL PE # 58201 PVC 3E 1 2428 Old Natchez T,c Td 46 JN -11A L E1.1N ERT C—deiT TN 38320 I :1 SAME �CFEPIG T NS LE 4� 1 1-B12121 N NCI`E IS PVC PH, 941-380-1574 PVC SILL POCKET INSERT PVC HD FMR REINF. HD FLAIR S-6239 H-6157 H-2115 6005A-T5 DOM AND EXTRUSIONS PVC FRAME oRnwn.1DATE: H-6193 EMK 06/19/15 —01 REV. : D LINE ITEMS NOT USEp: ---SIIET 25, 29-30NOTE: ALL ALUMINUM EXTRUSIONS ARE 6063-TS UNLESS OTHERWISE NOTED. 1:2 40F7 ANCH 6' MA 6' MA. IN ANCHOR LAYOUT - (FLANGE) INO SILL ANCHORS RE—REDI 4' MAX. NOTE 2 4' MAX. 8' MAX. C (TYT) ANCHOR LAYOUT - {PINT NOTES: 1. INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION. SILL ANCHOR SPACING SAME AS HEAD. 2. SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX. ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN IM6" IS PRESENT. LOAD BEARING SHIMS SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. WOOD SHIMS ARE NOT ALLOWED. 3. ANCHOR TYPE, SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS, SEE TABLE 1, SHEET 6. 4. ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST BE PROTECTED TO PREVENT REACTION. 5. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM SPECIFIED IN TABLE 1, SHEET 6. 6, ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETEICMU OPENINGS, EMBEDMENT SHALL BE BEYOND WOOD BUCKS, IF USED, INTO SUBSTRATE - 1 X BUCKS ARE OPTIONAL. 7. A MINIMUM CENTER -TO -CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS: 3" FOR MASONRY, 1" FOR WOOD AND METAL, 8. WOOD OR MASONRY OPENINGS, BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET, SHEET 6. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. 9. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: FMA/AAMA 100(FIN WINDOWS), FMAIAAMA 200(FLANGE WINDOWS), FMANVDMA 250(BOX WINDOWS), FMA/AAMAIWDMA 300(EXTERIOR DOORS) 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC Q Z � aZs z W Q ¢ W p m w zOQ �Gzf 1 3z103�x z 2x oatrW Op o 0 o a=�� ca ��i--zar-cna O pIn —5 z?U N < FzLL�z ou.0 T O ¢30wQx z x is I—o�z 0 w Q.�c'now<nw �a RO OO d F a �3a Tu =.� Na.58201 �^ a *° Ui srAreOF OR `11111110 \\�� 811812020 LUCAS A. TURNER, P.E. FL PE # 58201 2428 Old Natchez Trc Td Camden, TN 38320 PH. 941-380-1574 REST DESCRIPTXDN: vNCHOR SCHEDULE AND NOTES RAWN BY: DATE: EMK 06/19/15 WG#: REV.: CWS-1099 D DAB' SHEET 1:25 5OF7 SUBSTRATE BY SEE TABLE 1 PERIMETER SEA BYINSTALLER INSIDE AND OUT SEALANT BEHINi. FLANGE BY INST INSTALLATION A... _.. _.. SEE TABLE 1 TYPICAL HEAD ANCHORAGE MIN. EMBEDMENT SUBSTRATE SEE TABLE 1 BY OTHERS 1/44R��RDAETER SEE TABLE 1 �I[ MIN. EDGE DIST. SEE TABLE 1 INSTALLATION ANSEE TABLE 1 SEALANT STALLER E AND OUT ANT BEHIND FLANGE BY INSTALLER g HORIZONTAL SECTION 6 TYPICAL JAMB ANCHORAGE CONTINUOUS DEL V F BEAD OF SEALANT AROUND PERIMETER'@) ALL INDICATED POINTS BETWEEN FRAME AND SUBSTRATE BYINSTALLER FLALANTBENSTINDLLER FLANGE BY INSTA P I_IL.(- PERIMETER SEALANT 1/4' MAX SHIM BYINSTALLER INSIDE AND OUT SUBSTRATE BY OTHERS SEE TABLE i VERTICAL SECTION 6 TYPICAL SILL ANCHORAGE & NO SILL ANCHORS REQUIRED TABLE 1: APPROVED INSTALLATION FASTENERS FRAME TYPE SUBSTRATE TYPE ANCHOR TYPE MIN. EMBEDMENT MIN. EDGE DIST, FLANGE CONCRETE (2.0 KSI MIN.) 3/16" ITW TAPCON 1" 1-1/8" FLANGE HOLLOW OR GROUT -FILLED CMU (117 PCF MIN.) 3/16" IPV TAPCON 1" T FLANGE CONCRETE (2.85 KSI MIN.) 3/16" ELCO ULTRACON 1" 1" FLANGE GROUT -FILLED CMU (ASTM C-90) 3116" ELCO ULTRACON 1-114" 2-1/2" FLANGE 2X MIN. SOUTHERN PINE (G=0.55) EMS, ITW TAPCON OR ELCO ULTRACON 1-3/8" 718" FLANGE 2X MIN. SOUTHERN PINE (G=0.55) #10 WOOD SCREW 1-318" 7(8" FLANGE 16 GAUGE (0.060") MIN. STEEL STUD (33 KSI YIELD MIN) #10-16 HILTI KWIK-FLEX OR ITW TEKS SELF -DRILLING SCREW FULL THREAD THRU 0.060" 7/y6" FLANGE i18" ALUM. (6063-TS MIN.) OR y18" STEEL (33 KSI MIN.) #10 GRADE 5 SELF -TAPPING / DRILLING SCREW FULL THREAD THRU 0.125" 7111" FIN 2XMIN. SOUTHERN PINE (G=0.55) #10 WOOD SCREW 1-172" 112" NOTE: SLOPE SILL FRAME OPTION NOT SHOWN wlNDOW kglbsrsr e MIN. EDGE DIST. SEETABLET SUBSTRATE BEE TABLE SW44TH AVE. SEE TABLEI OCA 3 1/4" MAX SHIM WWW WS.CcFLORIDA34474 WWW.CWgS.CC 610 PVC p SINGLE HUNG SEE TA88EED1 NON -IMPACT PERIMETER SEALANT d F- z¢ Z U W O Q IW- O Oz L� LS BY INSTALLER INSIDEANDOUT W O 2 O ~ = ¢tJJ3}ODC >y ¢1 INSTALLATION ANCHOR z 2 2 g 6 it W q 0 SEE TABLE O Q DI-QUQyF� N0 Z SEALANT BEHIND FIN BY INSTALLER z z z' n y C 0 -' U U- C HORIZONTAL SECTION 6 TYPICAL `x F- =1y O O U- z K O H FIN ANCHORAGE HEAD AND SILL SIMILAR FOR FIN INSTALLATION "� }W-!- B, } . U N 00¢.C`W.w S~0 W3�W PERIMETER LANT BYINSTALLERALLER INSIDE AND OUT D HORIZONTAL SECTION 6 BOX FRAME INSTALLATION SIMILAR FOR SILL AND JAMBS FOR BOX INSTALLATION FLANGE REMOVAL NOTE: PARTIALLY OR FULLY REMOVING THE FLANGE, UP TO AND INCLUDING A BOX -FRAME APPLICATION IS ACCEPTABLE PROVIDED: - MIN. 1/4" FILLET OF CONSTRUCTION -GRADE ADHESIVE CAULK IS APPLIED INSIDE AND OUT, FULL PERIMETER, BY INSTALLER. -PRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS SHOWN FOR FLANGE WINDOWS. NXXX11 %I A'ITUIL✓<, y �9CEM$P� zr ^,Q N6. 58201^'. Au- '•�Al $fAiE S9f 2ttl,Fjw��k`lyYXX� 8/1812020 LUCAS A. TURNER, P.E. FL PE # 58201 2428 Old Natchez Trc TH Camden, TN 38320 PH. 941380-1574 - INSTALLATION DETAILS ixnW .Y: DAr: EMK 06/19/15 WGu: REV: CWS-1099 D °A[ff SHEET 1:2 60F7 1 518' MIN. EMBEDMENT — JN'MAXSHIM---, MAX 'HIM I- IN .1.. DIE, TYPICAL HEAD ANCHORAGE INSTALLATION ANCHOR 'OR N 3116' ELCO ULTRACON V MIN, EDGE DIST. CONCRETE CONTINUOUS DEL 1/4'BEAD OF US TRATE BY OTHERS SUBSTRATE SEALANT AROUND PERIMETER SEE TABLE 1, BHT 6 I> AT ALL INDICATED POINTS BETWEEN INSTALLER THE FRAME AND SUBSTRATE By INSTALLER 1 5/8' MIN. EMBEDMENT PERIMETER SEALANT B SEALANT BEHIND FLANGE BYINSTALLER INSIDE AND OUT a BYINSTALLER SEALANT BEHIND FLAN4GE114' MAX SHIM PERIMETER SEALANT SYINSTALLER— SOLID CONCRETE BYINSTALLER INSIDE AND OUT SUBSTRATE BY OTHERS SEE TABLE 1, BUT E HOPI 'ONTA.L SECTION INSTALLATION ANCHIC, IN, TYPICAL JAMB ANCHORAGE 16' ELCO ULTRACON CONTINUOUS DEL 114* BEAD OF SEALANT AROUND PERIMETER @ ALL INDICATED POINTS BETWEEN THE FRAME AND SUBSTRATE BYINSTALLER 114'MAX SHIM_ SEALANT BEHIND FLANGE �U BYINSTALLER PERIMETER SEALANT BYINSTALLER INSIDE AND OUT a 1/4' MAX SHIM EXTERIOR FINISH BY OTHERS SOLID CONCRETE OTHERLISS SUBSTRATE BY SEE TABLE 1, SHT 6 E VERTICAL SECTION 7 TYPICAL SILL ANCHORAGE NO SILL ANCHORS REQUIRED NOTE SLOPE SILL FRAME OPTION NOT SHOWN INSTALLATION ANCHOR 3116' ELCO ULTRACON CONTINUOUS DSL 1W BEAD OF SEALANT AROUND PERIMETER AT ALL INDICATED POINTS BETWEEN THE FRAME AND SUBSTRATE BY INSTALLER I- MIN, EDGE GIST. 1' MIN. EDGE DIST. 1900 SW 44TH AVE, OCALA, FLORIDA 34474 WWW'CWS.CC 610 PVC SINGLE HUNG NON -IMPACT WQ H2 2 .1 10 B' :�a� z x Z ou 0 z 0-Z':)' :2zou 11Z on '0 5 w X lc a 44, .50201 m pm 8/1812020 LUCAS A. TURNER, P.E. SOLID CONCRETE FL RE # 58201 SEALANT BEHIND FLANGE SUBSTRATE BY OTHERS 2426 ON! N' tchez TIC Tri BYINSTALLER SEE TABLE 1, BHT 6 Camden, TN 38320 PERIMETER SEALANT BY INSTALLER WOOD SUPPORT BY OTHERS PH. 941 -380-1574 INSIDE AND OUT SHEET DESCRIFT—ION, INSTALLATION DETAILS G'� HORIZONTAL SECTION POURED WALL I, �7C TYPICAL JAMB ANCHORAGE WOOD SUPPORTS HEAD AND SILL SIMILAR (NO SILL ANCHORS) — DATE. ORA"'Y EMIl � 06/19/15 .wG REV.: NOTE: INSTALLATION ON THIS SHEET ARE FOR SOLID POURED WALLS USED cWS-109 Z-1 D I SPECIFICALLY IN THE VILLAGES, FL. OR FOR SIMILAR SOLID POURED �71 SHEET WALL INSTALLATIONS 7 OF 7 General Notes A. CONCRETE & FOUNDATION RESIGN: L ALL CONCRETE GRADE BEAMS AND FOOTINGS SHALL BE 3000 PSI MINIMUM. 2. ALL CONCRETE FILLED SUPPORTED SLABS SHALL BE 2500 PSI MINIMUM, 3 I/2" NOMINAL THICKNESS. 3. 3000 PSI FIBER -MESH (3/4" PER CUBIC YARD MIN.) MEETING APPROPRIATE ACT AND ASTM REQUIREMENTS MAY BE USED IN LIEU OF WELDED WIRE MESH 4. ALL SLABS ON GRADE SHALL BE 4" THICK WITH FIBERMESH. TERMITE TREATMENT OF SOIL BENEATH SLAB IS NOT REQUIRED IF SLAB DOES NOT ABUT A WOOD FRAME STRUCTURE. NO WOOD FRAME STRUCTURE MAY BE BUILT ADJACENT TO OR ON TOP OF A SLAB WITHOUT TREATING THE SOIL FOR WOOD DEST ROYING ORGANISMS. 5. ALL REINFORCING SHALL CONFORM TO ASTM A615, BE GRADE 60 (60 KSI MIN.) DEFORMED BARS, 93 BARS MAY BE GRADE 40 6. ALL OVER POUR CONCRETE FILLED SUPPORTED SLABS SHALL BE 3000 PSI MIN., 2" MINIMUM_ THICKNESS. 7, SOIL BEARING PRESSURE SHALL BE A MINIMUM OF 1500 PSF. 8. THE CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING: OPC (PORTLAND CEMENT TYPE L- ASTM C 150). AGGREGATES - #6 STONE, ASTM C 33 SIZE NO. 67 LESS THAN 3/4". AIR ENTRAINING +/- 1 % - ASTM C 260. WATER REDUCING AGENT - ASTM C 494. CLEAN POTABLE WATER. OTHER ADMIXTURES SHALL NOT BE PERMITTED. 9. METAL WELDED WIRE SHALL CONFORM TO ASTM A 185. 10. PREPARE & PLACE CONCRETE ACCORDING TO AMERICAN CONCRETE INSTITUTE MANUAL STANDARD PRACTICE, PART 1, 2, & 3 ALONG WITH HOT WEATHER CONDITIONS RECOMMENDATIONS. 11. IF UTILIZING EXISTING CONCRETE FOR FOUNDATION, CONCRETE SHALL BE A MINIMUM OF 4" IN THICKNESS, VISIBLY FREE OF ANY STRUCTURAL EXCESSIVE CRACKING, SPALLING OR OTHER DETERIORATION. B. MASONRY: I. CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR. 2.ALL MORTAR SHALL BE OF TYPE M OR S. 3.ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 3/8". 4.PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS 5'-0" IN HEIGHT. C. ALUMINUM: I . ALL STRUCTURAL ALUMINUM SHALL CONFORM TO THE MINIMUM REQUIREMENTS OF 6005-T5 FOR ALLOY WITH A MINIMUM THICKNESS OF 0.040" FOR SUPPORTING MEMBERS. 2. WHERE KICK PLATES ARE USED A MINIMUM THICKNESS OF 0.024" SHALL APPLY. 3. STRUCTURAL ALUMINUM DESIGN CONFORMS TO "PART I -A - SPECIFICATIONS FOR ALUMINUM STRUCTURES - ALLOWABLE STRESS DESIGN° OR "PART I-B - SPECIFICATIONS FOR ALUMINUM STRUCTURES - BUILDING LOAD AND RESISTANCE FACTOR DESIGN" OF THE CURRENT ALUMINUM DESIGN MANUAL PREPARED BY THE ALUMINUM ASSOCIATION, INC.WASHINGTON D.C. THE FLORIDA BUILDING CODE, 7TH EDITION ( CHAPTER 16 STRUCTURAL DESIGN & CHAPTER 20 ALUMINUM). 4. WHERE ALUMINUM COMES INTO CONTACT WITH STEEL, OR PRESSURE TREATED LUMBER PROVIDE DIELECTRIC SEPARATION. 5. ALUMINUM MEMBERS SHALL BE STITCHED WITH NO LESS THAN #10 SMS 6" FROM THE ENDS AND 12" ON CENTER, IF USING #12 SPACING MAY BE 24" ON CENTER, 6. VINYL AND ACRYLIC; PANELS SHALL BE REMOVABLE. THEY SHALL BE IDENTIFIED WITH A DECAL ESSENTIALLY STATING "REMOVABLE PANEL SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 MPH". DECAL SHALL BE PLACED SO IT IS VISIBLE WHEN PANEL IS INSTALLED, D. FASTENERS: i. ALL LAG BOLTS SHALL CONFORM TO STAINLESS STEEL TYPE 300 18-8, WITH STANDARD FLAT WASHER UNLESS MANUFACTURER GALVANIZES BOLTS SPECIFIES FOR USE WITH ACQ PRESSURE TREATED WOOD. 2. HEX BOLTS HAS TO BE ASTM A 325, PLATED WITH STANDARD FLAT WASHERS AND NUTS. 3, ALL CONCRETE SCREWS SHALL BE, SIMPSON, HILTI, RAWL, TAPCON, REDHEAD, DYNABOLT, OR APPROVED EQUAL. 4. ALL METAL TIES AND ASSOCIATED ACCESSORIES SHALL BE HOT DIPPED GALVANIZED. S. ALL LAG BOLTS SHALL HAVE A MINIMUM EMBEDMENT OF 8X BOLT DIAMETER INTO STRUCTURAL FRAMING (G=.42 MIN.). 6. LAG BOLTS AND SCREWS INTO WOOD FRAMING SHALL BE PROVIDED WITH PILOT HOLES HAVING A DIAMETER NOT GREATER THAN 70 PERCENT OF THE THREAD DIAMETER OF THE BOLT OR SCREW. ALL LAG BOLTS AND SCREWS SHALL BE INSERTED IN PILOT HOLES BY TURNING AND UNDER NO CIRCUMSTANCES BY DRIVING WITH A HAMMER. 7. R RLI, EXPANSION ANCHORS SHALL BE DESIGNED IN ACCORDANCE WITH THE SPECIFIC MANUFACTURER'S REQUIREMENTS AND ALLOWABLE LOADS AND SHALL ONLY BE APPLIED IN CONDITIONS ACCEPTABLE TO MANUFACTURER FASTENERS SHALL BE A MINIMUM OF SAE GRADE #5 OR BETTER ZINC PLATED, 8. ALL FASTENERS CONNECTING ALUMINUM COMPONENTS OR PRESSURE TREATED LUMBER ARE STAINLESS STEEL TYPE 300 18-8, UNLESS MANUFACTURER GALVANIZED BOLTS SPECIFIES FOR USE WITH ACQ PRESSURE TREATED WOOD, OR OTHERWISE NOTED ON PLANS, 9, ALL FASTENERS SHALL COMPLY WITH ASTM A153. 10. ALL CONNECTORS SHALL COMPLY WITH ASTM A653 CLASS G-185. 11. FOR SMS, THE MINIMUM CENTER -TO -CENTER SPACING SHALL BE 3/4" AND MINIMUM CENTER -TO -EDGE SHALL BE 1/2" UNLESS NOTED OTHER WISE. 5. SCREENING MATERIAL SHALL BE 1.8X14X0.013 OR EQUIVALENT DENSITY SCREEN MESH ONLY UNLESS NOTED OTHERWISE, 6. EMERGENCY ESCAPE & RESCUE OPENING PER FBC R310.1 SHALL BE VERIFIED BY CONTRACTOR & BUILDING OFFICIAL T ENCLOSED ADDITIONS TO MANUFACTURED HOMES SHALL NOT CHANGE THE EXIT FACILITIES FOR EGRESS PER HUD 3280.105, (a) THROUGH (a)(2)(iv), SO THAT THE DISTANCE TO EXIT DIRECTLY OUTSIDE FROM ALL BEDROOMS IS LESS THAN 35', AND, SO THAT TWO EXITS DIRECTLY OUTSIDE ARE STILL MAINTAINED. A CARPORT OR SCREEN ROOM SHALL BE CONSIDERED AS OUTSIDE. NON -HABITABLE SUNROOMS OR HABITABLE LIVING SPACE, MAY BE ADDED WHERE AN EXIT DOOR WAS LOCATED AS LONG AS A NEW EXIT DOOR IS ADDED AND MEETS THE REQUIREMENTS OF HUD 3280.105. E. REFERENCE STANDARDS: ASTM E 119 ASTM E 1300 ASCE 7 -16 AA AS 5L f$ FN LUIIHc1I�iv(F TA 1B "'`r I/ .rU K4G ASTM ASTM ES FLORIDA B`U DING r . " ASTM T�f �}s A 4� i ASTM 6 i` f ASTM � I s € °.o� :' r.�:. 4. ..._... ASTM JI��ANCE�- , ASTM A28 FLORIDA BUILDING CODE (CHAPTERS 16,20 AND 23) 7TH EDITION CURRENT ALUMINUM DESIGN MANUAI, ABBREVIATIONS: THE FOLLOWING LIST OF ABBREVIATIONS IS NOT INTENDED TO REPRESENT ALL THOSE USED ON THESE DRAWINGS, BUT TO SUPPLEMENT THE MORE COMMON ABBREVIATIONS. 1. TYP -- TYPICAL 2. SIM --SIMILAR 3. DON --UNLESS OTHERW -4.6oE t KW & 4. CONT--CONTINUOUS S. VIF--VERIFY IN FIELD ( 6 f' -I-- r1 RESPONSIBILITY: DLAN L ALL SITE WORK SHALL BE PERFORMED BY A LICENSED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING/ CODES, LOCAL ORDINANCES, ETC. 2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND DETAILS, NOTIFYING ENGINEER OF ANY DISCREPANCIES BETWEEN DRAWINGS, FABRICATED ITEMS, OR ACTUAL FIELD CONDITIONS. 3. THESE DRAWINGS REPRESENT THE ACCEPTABILITY OF THE 'SUNROOM' ROOM ADDITION ELEMENTS AS PROVIDED BY THE CONTRACTOR, 4. ALL DETAILS ON THESE DRAWINGS ARE ENGINEERED BASED ON INFORMATION PROVIDED BY THE CONTRACTOR AND MANUFACTURER. S. ANY DETAILS NOT SHOWN ARE TO BE ENGINEERED BY A LICENSED P.E. IN ACCORDANCE WITH STANDARD ENGINEERING PRACTICES. H. MISCELLANEOUS: 1. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME WITHOUT A MANUFACTURERS HOST BEAM, IF NO HOST BEAM IS PRESENT A SEPARATE 4TH WALL SUPPORT SYSTEM SHALL BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. 2. IF ENCLOSURE CONTAINS A SWIMMING POOL OR SPA, THE ENCLOSURE SHALL COMPLY WITH RESIDENTIAL SWIMMING BARRIER REQUIREMENTS OF THE FBC 7TH EDITION R4501.17.1 IN ITS ENTIRETY. s. DOOR LOCATIONS MAY BE DETERMINED IN THE FIELD BY CONTRACTOR 4. IF PAVERS ARE UNDER ALUMINUM MEMBERS THEY SHALL HAVE EPDXY ADHESIVE I'D CONCRETE OR IF USING GROUT, ENSURE BONDING AGENT IS USED FIRST. 1. ULTIMATE DESIGN WIND SPEED Vult, (3 SECOND GUST): 130 MPH NOMINAL DESIGN WIND SPEED Vasd: 101 MPH 2. RISK CATEGORY: I 3. WIND EXPOSURE: B 4. INTERNAL COEFFICIENT: SUNROOM (ENCLOSED STRUCTURE): +/- 0.18 5. WIND LOADS: FACTOR APPLIED TO WIND LOADS FOR ALLOWABLE STRESS DESIGN: 0.6 SOLID ROOF (MWFRS): 20 PSF COMPONENT & CLADDING PRESSURES: ROOF ZONE 1: 12.4/-48.4 PSF WALLS ZONE 4: 30.4/-33.0 PSF, ZONE 5: 30.4/40.7 PSF 6. FOUNDATIONS PER "A" OF GENERAL NOTES AND SITE SPECIFIC DETAIL. 7. SOLID ROOF TYPE: T X48" COMPOSITE PANELS, FL 7561 OR EQUIV. 2 x 2:---------------------------------------2" x 2" x 0.044„ 3 x 2:---------------------------------------3" x 2" x 0.050" 2 x 3:---------------------------------------2" x 3" x 0.050„ 2 x 3:---------------------------------------2" x 3" x 0.070" 2 x 4:---------------------------------------2" x 4" x 0.050„ 2 x 5:---------------------------------------2" x 5" x 0.G50° 3 x 3:---------------------------------------3 x 3" x 0.072" 3 x 3:---------------------------------------3 x 3" x 0.093„ 3 x 3:---------------------------------------3 x 3" x 0.125„ 4 x 4:---------------------------------------4 x 4" x 0.125„ OPEN BACK SECTIONS 1 x 2:---------------------------------------- 1" x 2" x 0.040„ 1 x 3:----------------------------------------1" x 3" x 0.045" 2 x 2 Snap: ---------------------------------- 2" x 2" x 0.045" 2 x 3 Snap:---------------------------------2" x 3" x 0,050" 2 x 4 Snap:--------------------------------- 2" x 4" x 0.045' .6 ■ li ' i s 2 x 4 SMB:---------------------- 2" x 4" x 0.044" x 0.100" 2 x 5 SMB:---------------------- 2" x 5" x 0.050" x 0.118" 2 x 6 SMB:---------------------- 2" x 6" x 0.050" x 0.120" 2 x 7 SMB:---------------------- 2" x 7" x 0.057" x 0.120" 2 x 8 SMB:---------------------- 2" x 8" x 0.072" x 0,224" 2 x 9 SMB:---------------------- 2" x 9" x 0.072" x 0.224" 2 x 10 SMB:------------------- 2" x 10" x 0.092" x 0.374" INDEX: S-1 GENERAL NOTES S-2 PLANS AND ELEVATIONS S-3 SUNROOM DETAILS S-4 SUNROOM DETAILS I HEREBY CERZjkYVftI4hfl1 I144yy REV IEWED THIS PLA B7$ COMPAE ANDp 7TH F s S ING EDIT R" I'J°E dT2�%s4¢°4b EXj°T BU. ° �s U S 7"I" 111 11 w,10 PROFESSIONAL ENGINEER SEAL ENGINEER OF RECORD David • #. Thomas!; P.E. Ian J. Foster P.E. FLORIDA LICENSE NUMBER: 93654 Joel Falardeau P.E. FLORIDA LICENSE NUMBER: 70667 Erik Stuart P.E. FLORIDA LICENSE NUMBER: 77605 FBC Plans & Engineering Services, Inc. 5344 9th St. Zephyrhills, Fl. 33542 Phone:(813)838-0735 Email: erb@fbcplans.com Website: www.fbcplans.com C.O.A. - #29054 I DATE: 10/12/2022 1 INNEFORULWA �tTt1111�1�'. � i ► _: 1/ lid %. r � Ii � i� JONES 37417 TEABERRY LOOP WEDGEWOOD MANOR ZEPHYRHILLS, FL. 33542 CONTRACTOR: SUNSTATE ALUMINUM GENERAL NOTES EXISTING�/ HOUSE OVERHANG EXISTING PROPOSED HOME LEDGER BOARD (WOOD OR ALUMINUM) TO RUN ALONG RAKE OF COMPOSITE ROOF, UP AND DOWN, BOTH SIDES �0 Ji 2A013 Q 2k3 X X - 3 2, x 2,3. Q+1 1 2' -11" L 31-111i V 12' PROPOSED 3" X.024" COMPOSITE PANEL ROOF W/ SHINGLES FL 7561 OR EQUIV. 4" CONCRETE SLAB W/ 12"X 18" FOOTER PROPOSED SUNROOM CAT III 2X6 SMB RIDGE PROPOSED SINGLE -HUNG PROPOSED GLASS WINDOW HARDIE-PLANK TYPICAL SIDING, TYPICAL PROPOSED PROPOSED SINGLE -HUNG 3" X.024" COMPOSITE GLASS WINDOW [TYPICAL PANEL ROOF W/ SHINGLES I 2X3 FL 7561 OR EQUIV. 2X3 2X3 2X3 EXISTING F _2X3 2X3 _2X3 2X3 0) HOME 1 0 0 C� co EXIST. HOME x X U') �0 �o x x M ---------- --- ---------- --- �/ rx_1/ Cj r x x C'j x -x co L_J 2X3 2X3 2X3 2X3 2X3 2X3 /IX3 IX3 1X3 1X3 - -- — — — — — — — — — GRADE —GRADE PROPOSED 4'CONCR7-TESLAB /12'X1j'FOOTERj t 3'-6" 3' T- HARDIE-PLANK SIDING KICK PLATE 3'-1" 2 T-l" 10, TYPICAL 12' SIDE ELEVATION REAR ELEVATION NOTES: 1. WINDOWS AND DOORS TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 2. WINDOWS AND DOORS ARE NON -IMPACT. 3. ALL SEAMS OF SUNROOM TO BE SEALED WITH SILICONE CAULKING, ISYMBOLLEGEND I (DI TEMPERED GLASS I HEREBY CERTIFY THAT I HAVE REVIEWED THIS PLAN AND FOUND IT TO BE IN COMPLIANCE WITH ��3qWrlp NDFBC7TH EDITION RESIDIkN'�N BUILDING LO Sind 41- '0111111111W0 PROFESSIONAL ENGINEER SEAL ENGINEER OF RECORD David W. Smith P.E. FLORIDA LICENSE NUMBER: 53608 Thomas L. Hanson P.E. FLORIDA LICENSE NUMBER: 38654 Ian J. Foster P.E. FLORIDA LICENSE NUMBER: 93654 Joel Falardeau P.E. FLORIDA LICENSE NUMBER: 70667 Erik Stuart P.E. FLORIDA LICENSE NUMBER: 77605 FBC Plans & Engineering Services, Inc. 5344 9th St. Zephyrhills, Fl. 33542 Phone: (813)838-0735 Email: erb@fbcplans.com Website: www.fbcplans.com C.O.A. - #290S4 DATE: 10/12/2022 DRAWN BY: DENNIS W. DUNN REVISION: DATE: RO 1 RO 2 RO 3 RO 4 JOB # 22 1007 083 JOB NAME & ADDRESS: JONES 37417 TEABERRY LOOP WEDGEWOOD MANOR ZEPHYRHILLS, FL. 33542 CONTRACTOR: SUNSTATE ALUMINUM PLANS AND ELEVATIONS S-2 #10 TEK SCREW AND 1-1/4" O #10 TEK SCREW AND 1-1/4"0 1 HEREBY CERTIFY THAT I HAVE REVIEWED NEOPRENE WASHER AT 8" D.C. (USE COMPOSITE NEOPRENE WASHER AT 8" D.C. (USE COMPOSITE THIS PLAN AND FOUND IT TO BE IN COMPLIANCE WITHAL 7-16 AND FBC 7TH FASTEN COMPOSITE PANEL TO ALUMINUM RIDGE CAP SCREW LENGTH EQUAL TO COMPOSITE PANEL ROOF SCREW LENGTH EQUAL TO COMPOSITE PANEL ROOF EDITION R,�SlpENTIAL AND EXISTING BEAM W/ #10 TEK SCREW AND 1-1/4"0 FLASHING FASTENED TO PANEL THICKNESS PLUS 1" MIN.) PANEL THICKNESS PLUS 1 MIN.) BU��QW 1 11111,// NEOPRENE WASHER AT 8" D.C. (USE COMPOSITE PANEL W/ #8 X 3/4" ()ST SCREW LENGTH EQUAL TO COMPOSITE TEK SCREW AT 12" O.C. PANEL THICKNESS PLUS 1" MIN.) /Z S CE OOF Co""OS/TFRoop CO�A?OSi 2X3 PATIO 2X3 PATIO 0 0 EDGE / END BEAM EDGE / END BEAM 0, 2X6 SMB (3) 3/8" THRU BOLTS, 2X3 UPRIGHT 2" X 2" X 0.125" ANGLE 11 140 FL RIDGE BEAM WASHERS, AND NUTS, CORROSION RESISTANT W1 (3) #10 X 3/4" TEK SCREW EACH LEG, EACH SIDE OF UPRIGHT �pl °e® x, rrrrr (4) #10 X 4"TEK SCREW ALUMINUM POST INTO SCREW BOSS 2X3 OR 3X3 UPRIGHT L—Av� W"IMWI, ENGINEER SEAL PER PLAN ENGINEER OF RECORD COMPOSITE PANEL ROOF, UPRIGHT, AND COMPOSITE PANEL ROOF, UPRIGHT, AND COMPOSITE PANEL ROOF, BEAM EDGE END BEAM CONNECTION DETAIL EDGE / END BEAM CONNECTION DETAIL E David W. Smith P.E. AND POST CONNECTIONS AT RIDGE OPTION (INTERNAL) OPTION (EXTERNAL) FLORIDA LICENSE NUMBER: 53608 F— Thomas L. Hanson P.E. RIDGE BEAM TO LEDGER EXISTING BOARD PER'BEAM TO ALUMINUM' OR FLORIDA LICENSE NUMBER: 38654 WOOD FRAME HOME [ATTACH 'BEAM TO WOOD' CONNECTION DETAILS Ian 1. Foster P.E. ATTACH SHINGLES TO COMPOSITE ROOF WITH FLORIDA LICENSE NUMBER: 93654 LEDGER BOARD (WOOD OR ALUM.) — — — — — — — — - PL 2000 PREMIUM ADHESIVE OR EQUIV. AND ATTACH TO WOOD WALL W1 (2) 1/4"0 RIDGE BEAM PROVIDE (2) 3/8" TO 1/2" THICK CONTINUOUS E Joel Falardeau P.E. LAG SCREWS AT EACH STUD 16" D.C. PER PLAN ADHESIVE LINES PER SHINGLE SPACED 4%6" APART. W/ 2-1/2" EMBEDMENT MIN.—\ — — — — — — — — ASPHALT -OR- FLORIDA LICENSE NUMBER: 70667 SHINGLE ADHESIVE MEMBRANE APPLIED TO METAL, SHINGLES COMPOSITE PANEL ATTACHED SCREWED OR NAILED THROUGH MEMBRANE PER NOTE. Erik Stuart RE, TO HEADER CHANNEL W/ #10 X 3/4" TEK SCREW AND 1"0 NEOPRENE—\— COMPOSITE STANDARD ROOFING NAIL FLORIDA LICENSE NUMBER: 77605 WASHER AT 8" D.C. TOP AND BOTTOM PANEL ROOF OR WAFER HEAD SCREW (6 PER SHINGLE) FBC Plans & Engineering APPLY FLASHING AT WALL AND ATTACH COMPOSITE PANEL ROOF Services, Inc. TO COMPOSITE PANEL W1 #8 X 3/4" TEK SCREW AT 12" D.C. CAULK ALL SEAMS 5344 9th St. OR STRIP SEALANT BETWEEN WALL Zephyrhills, Fl. 33542 AND HEADER CHANNEL NOTES: Phone: (813)838-0735 1. FOR STARTER ROWS, ADHESIVE LINE SHALL Email: erb@fbcplans.com FASTEN HEADER CHANNEL 0.060" MIN. BE PLACED WITHIN V OF PANEL EDGE. Website: www.fbcplans.com TO WOOD WALL WITH 1/4"0 LAG HEADER CHANNEL 2. ASPHALT SHINGLES ADDED FOR AESTHETIC PURPOSES. C.O.A. - #29054 SCREW AT EACH STUD 16" O.C. W/ 2-112" EMBEDMENT MIN, SCREEN ROOM SHINGLE DETAIL DATE: 10/12/2022 COMPOSITE PANEL ROOF, RIDGE BEAM AND LEDGER BOARD DRAWN BY: DENNIS W. DUNN CONNECTIONS TO HOST WOOD WALL REVISION: DATE: RO 1 R02 4I I 2" X 2" X 0.125" ANGLE (0 GRADE (3) 912 X 3/4" TEK SCREW (2) 3/8"O MACHINE BOLTS, ALUMINUM 3X3 POST RO 3 CONCRETE 2X3 FASTENING UPRIGHT TO ANGLE NUTS AND WASHERS OR (4) #14 X 3/4� TEK SCREWS EACH SIDE INTERNAL BASE RO 4 1�� BELOW GRADE UPRIGHT 0 0 (TYPICAL EACH SIDE) OPTION I JOB# 22 1007 083 (2) #5 REBAR CONTINUOUS, IX3 O.B.BASE MEMBER EXTERNAL BASE 11 GAINTERNAL ALUMINUM BASE OPTION 2 . "12 25" MIN. OVERLAP ALL JOINTS, (TYPICAL EACH SIDE) PREDRILL VERTICAL FLANGES JOB NAME & ADDRESS: ON 3" HIGH CHAIRS TYPE 11 MONOLITHIC SLAB p (1) 3/8" 0 CONCRETE SCREW 2" X 2" X.125" ANGLES EXTERNAL OR EQUIVALENT POST BASE (4) 1/4"0 CONCRETE ANCHORS JONES MODERATE SLOPE FOOTING ANCHOR INTO ANGLE AND O.B. W/ 3" EMBEDMENT, 3" MIN. EDGE 37417 TEABERRY LOOP SLOPE: 2": 12" - 3": 12" INTO CONCRETE AS SHOWN OR (2) 3/8"0 CONCRETE ANCHORS PER DISTANCE AND 2" MIN. SPACING THRU ANGLE INTO CONCRETE AND EXTERNAL FLANGE WITH 2" D.C. SPACING, WEDGEWOOD MANOR TYPE 11 MONOLITHIC SLAB FOOTING 3" (MIN.) 1/4"0 CONCRETE SCREW ANCHOR THRU O.B. 6" FROM ENDS AND 2-3/4" MIN. EMBEDMENT AND 3" MIN. CONCRETE EDGE DISTANCE ZEPHYRHILLS, FL. 33542 NOTES FOR ALL FOUNDATION TYPES: 24" D.C. BETWEEN UPRIGHTS. CONCRETE,,* CONTRACTOR: 1. THE FOUNDATIONS SHOWN ARE BASED ON A MIN. EMBEDMENT SHALL BE 2-3/4" MINIMUM SOIL BEARING PRESSURE OF 1500 PSF. AND 3" EDGE DISTANCE MIN. . SUNSTATE ALUMINUM 2. THE SLAB / FOUNDATION MUST BE CLEARED OF (TYPICAL EACH SIDE) ALL DEBRIS, AND COMPACTED PRIOR TO POURING 3X3 POST CONNECTION TO CONCRETE DETAIL OF ANY CONCRETE. 2X3 UPRIGHT W/ 1X3 O.B. MEMBER SUNROOM DETAILS 3. CONCRETE SHALL MEET THE SPECIFICATIONS CONCRETE BASE CONNECTION IN THE S-1 GENERAL NOTES PAGE. - S3 I HEREBY CERTIFY THAT I HAVE REVIEWED THIS PLAN AND FOUND IT TO BE IN 1/4" STRUCTURAL GRADE THERMO-PLY ATTACH RECEIVING CHANNEL COMPLIANCE WITH ASCE 7-16 AND FBC 7TH EDITION RESIDENTIAL AND EXISTING z SHEATHING OR.024 MIN. ALUMINUM W/ #10 X 3/4" TEK SCREW AT 12" O.C. BUILDING VA1IHIIjf,, COIL FASTENED TO ALUMINUM FRAMING 0.062" MIN, RECEIVING CHANNEL W1 #10 X 3/4" TEK SCREW AT 8" O.C. COVER OS ER 0.062" MIN, RECEIVING w (OPTIONAL AT TOP OR BOTTOM OF POST) ........ a- WITH HARDIE-PLAMK SIDING PER MFGR'S SPECS. CHANNEL TOP AND E FASTEN EACH POST TO RECEIVING Jr - BOTTOM OF POST 2X ALUM PER PLAN CHANNEL W1 (2) #10 X 3/4" TEK D . SCREWS, BOTH SIDES ExIS7- PAv 0 a LJ 0.062" MIN. ANGLE !..I 2X PER PLAN JK ATTACH RECEIVING W/ (2) #10 X 3/4" TEK SCREWS CHANNEL W/ #10 X 3PER FLANGE EACH SIDE3/4" TEK SCREW AT 12" O.C. TOP AND BOTTOM OF POST 2X ALUMINUM ---- , 1 1/4" STRUCTURAL GRADE THERMO-PLY /0 F L `1�2X ALUM. POST AT 16" D.C. POST AT 16" D.C. SHEATHING OR.024" MIN. ALUMINUM FASTEN TOP AND BOTTOM TYPICAL OF EACH POST TO RECEIVING 1 X 0. B. PER PLAN COIL FASTENED TO ALUMINUM FRAMING rts's 10 MIN. ANGLE W1 #10 X 3/4" TEK SCREW AT 8" O.C. COVER PR�/ftWjqqA4 M0 EER SEAL CHANNEL W/ (2) #10 X 3/4" 0.062" MIN. ANGLE TEK SCREWS, BOTH SIDES W/ (2) #10 X 3W TEK WITH HARDIE-PLANK SIDING PER MFGR'S SPECS. CONCRETE CONCRETE SCREWS PER FLANGE ENGINEER OF RECORD EACH SIDE OF POST (OPTIONAL AT TOP OR D PER PLAN E David W. Smith P.E. RECEIVING CHANNEL ANGLE BOTTOM OF POST) FLORIDA LICENSE NUMBER: 53608 OPTION OPTION ABOVE BELOW WINDOWS Thomas L. Hanson P.E. WINDOWS ALUMINUM INFILL FRAMING FLORIDA LICENSE NUMBER: 38654 AND VINYL SIDING DETAIL Ian J. Foster P.E. FLORIDA LICENSE NUMBER: 93654 FASTEN SMB TO RECEIVING Joel Falardeau P.E. CHANNEL W/ #10 X 3/4" TEK SCREW EXISTING WOOD FLORIDA LICENSE NUMBER: 70667 (1 PER INCH OF BEAM HEIGHT) — — — — — — — — — — — — FRAME WALL STAGGERED, BOTH SIDES 2X EDGE / END BEAM 00 Erik Stuart P.E. 1 0' FLORIDA LICENSE NUMBER: 77605 E2X EDGE I END PER PLAN 0 77710WO LAG SCREW O�— W/ 1-1/2" EMBEDMENT FBC Plans & Engineering 2XSMB PER PLAN MIN. 6" FROM TOP AND o 2" X 2" X 1/8" X'BEAM DEPTH' BOTTOM AND 24" O.C. Services, Inc. 0 I-D< L z _j RECEIVING CHANNEL can 5344 9th St 0i 5� CL W/ (1) 1/4" LAG SCREW Zephyrhills, Fl. 33542 Uj W/ 1-1/2" EMBEDMENT MIN. Phone: (813)838-0735 062 MIN. RECEIVING CHANNEL < a- INTO WALL W1 (4) #10 X 3/4" TEK In Email: erb@fbcplans.com j I 1X OR 2X FASTENED TO POST W/ #10 X 3/4" TEK SCREW EACH SIDE INTO BEAM J PER PLAN Website: wv,,w.fbcplans.com SCREW (1 PER INCH OF BEAM C.O.A. - #29054 HEIGHT) STAGGERED EDGE / END BEAM TO HOST STRUCTURE DETAIL BEAM TO ALUMINUM CONNECTION DATE: 10/12/2022 DRAWN BY: DENNIS W. DUNN REVISION: I DATE: FASTEN RECEIVING CHANNEL TO SMB W/ #10 X 3/4" TEK SCREW (1 SCREW PER INCH OF BEAM HEIGHT) STAGGERED, BOTH SIDES 1-1/2'X 2-1/8" X 1-1/2"X 0.062"-� INTERNAL OR EXTERNAL RECEIVING CHANNEL 2XSMB PER PLAN I.: 0 oz FASTEN RECEIVING CHANNEL C) :E TO STRUCTURAL WALL MEMBER I i� � LL WITH 1/4"0 X 2" LAG SCREW (I SCREW PER 2 INCHES OF BEAM HEIGHT) BEAM TO WOOD CONNECTION 2X ALUM. — PER PLAN --------- no,rinfli 41) 0.062" MIN. ALUM. INTERNAL OR EXTERNAL RECEIVING CHANNEL W/ (4) #10 X 3/4" TEK SCREWS INTO UPRIGHT AND (2) #12 X 3/4" TEK SCREWS EACH LEG INTO GIRT 2X ALUM. PER PLAN 0.062" MIN. ANGLE CLIP— I I ALUM. UPRIGHT W/ (2) #12 X 3/4" TEK i I PER PLAN SCREWS EACH LEG OPTION #1 — CHAIR RAIL AND GIRT CONNECTIONS 11=1 JOB # 22 1007 083 JOB NAME &ADDRESS: JONES 37417 TEABERRY LOOP WEDGEWOOD MANOR ZEPHYRHILLS, FL. 33542 CONTRACTOR: