HomeMy WebLinkAbout22-50875335 Eighth Street
Zephyrhills, FL 33542
Phone: (813) 780-0020
Fax: (813) 780-0021
oww"am
1AFOM I
Issue Date: 10/27/2022
REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection, whichever is greater, for each subsequent reinspection.
Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies.
MIRM-Tr-T MWIVIF 01 � if. — . 0
Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
A
—7y, rid_
44
CONTRACTOR SIGNATURE PEfAIT OFFICEt)
PER
0
9 %tel I!, WTANN 0 �W
813-780-0020 City of Z phyrhillS Permit Application Fax-813-780-0021
Building Department
,. .,.
..�:: • wit �.�.�� � r �.,r,► � - ii: ��, i #
#
WORK PROPOSED
NEW r
INSTALL L�j
REPAIR
PROPOSED USE
SFR [:D
COMM OTHER
TYPE OF CONSTRUCTIONEl
.FRAME
DFSCRMLTM-9r,4MZK
Fin-stallation of a roof -mounted photovoltaic solar panel system.
SUILtaINGSIZE So FOOTAGE HEIGHT
c'_�]BUILDING $ VALUATION OF TOTAL CONSTRUCTION
ELECTRICAL $ , z AMP SERVICE PROGRESS ENERGY W.R.E.C.
PLUMBING $
MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION
GAS ROOFING SPECIALTY = OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO
rSunrun Installation Services, Inc.
i.. #W. itSunrun Installation Services, Inc,
1 !
•�-,�
. i
a • w
�.�;, c A. : #i it ! 4.. • „.. �..
i Directions:
Fill out application completely.
Owner & Contractor back of application,
If over $25M, a Notice of Commencement Is require4d. (AfC upgrafte over 1
Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same
COUNTER
OVER THE
Reroots if shingles Sewers Service Upgrades AIC Fences (Plot(Survey/Footage)
813-780-0020 City of Zephyrhilis Peit Application Fax-813-780-0021
BuiAing Department
n eniftled to permitting privileges In Paw�o nty.
114-awwwal
all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do we* and Installation as
indicated, I certify that no work or installation has commenced prior to issuance of a per and that all work will be performed to meet standards of all
laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I
understand that the regulations of other government agencies may of to the intended work. and that it is my responsibility to identify what actions I
must take to be in compliance. Such agencies include but are not limited to:
Department of Environmental Protection -Cypress Bayheads, Wetiand Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment,
Southwest Florida Water Management District -Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
Army Corps of Engineers -Seawalls, Docks, Navigable Waterways.
Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment,
Septic Tanks,
US Environmental Protection Agency -Asbestos abatement.
Federal Aviation Authority -Runways.
I understand that the following restrictions apply to the use of fill:
Use of fill is not allowed in Flood Zone 'V" unless expressly permitted.
If the fill material is to be used in Flood Zone "A, it is understood that a drainage plan addressing a
. compensating volume' will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Flodda.
If the fill material is to be used in Flood Zone "X in connection with a permitted building using stem wall
construction, I certify that fill Will be used only to fill the area within the stem wall.
If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to qdversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to
U. cin tru I n- I n * t n th t mnit m v n
JILUM T1filtal 101MAIlMiN
"(14WAIM
I 210"VIR&I mvz'l 4 4,
Who War�lly orally to me or has/have produced
s identification.
Nom
598munrl
..............
Astra v.1.725
September 9, 2022
s"'unrun
WS
CAT 1
Subject :Structural Certification for Proposed Residential Solar Installation.
VAE
James Matthew Walsh, Stale of Florida,
Job Number: 802R-962PERE; Rev Al
,,"o. E
Professjonat Engineer. License No. 84923
Client: Amaury PerezCompanioni
-7
No 84Q
This item has keen digtolly signed and seated
Address: 39962 Harmon Grove Ct, Zephyrhills, FL, 33540
/ 36-
9.2
V James Matthew Walsh PE on 91 / OZ! using
a -
Digital Printed
-qi
STA-4 'OF 41 Z-
a Signature. copies of this
document ate net conside,ed signed and sealed
0
A-t.-
and the SHA aulthenticalion code must oe
verilteci or, electronic copies.
Whom To WhoIt May Concern
t ORM
10NAV-�\\\
/OutailtitO
Afield observation of the existing structure at the address indicated above was performed by a site survey team from
Sunrun. Structural
evaluation of the loading was based on the site observations and the design criteria
listed below,
Design Criteria:
2020 FBC (7th Ed.) AMENDMENTS TO 2018 IRC/IBC/IEBC, 7-16 ASCE & 2018 NDS
Basic Wind Speed V = 138 mph, Exposure B
Ground Snow Load = 0 psf
Based on this evaluation, I certify that the alteration to the existing structure by the installation of the PV system meets the requirements of the
applicable existing and/or new building code provisions referenced above.
Additionally, I certify that the PV module assembly including all attachments supporting it have been reviewed to be in accordance with the
manufacturer's specifications.
225 Bush St. Suite 1400 San Francisco, CA 94104
SCOPE OF WORK
GENERAL NOTES
LEGEND AND ABBREVIATIONS
TABLE OF CONTENTS
PAGE # DESCRIPTION
• SYSTEM SIZE: 760OW DC, 600OW AC
• ALL WORK SHALL COMPLY WITH 2O20 FBC (7TH ED.) AMENDMENTS TO 2018
SOLAR MODULES
PV-1.0
• MODULES: (19) HAN A Q-CELLS: Q.PEAK DUO BLK
IRC/IBC/IEBC, MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND
SE
SERVICE ENTRANCE
COVER SHEET
ML-G10+ 400
INSTALLATION INSTRUCTIONS.
PV-2.0 SITE PLAN
• INVERTERS: (1) SOLAREDGE TECHNOLOGIES:
SE600OH-USSN
• PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017.
MP
MAIN PANEL
HNT
PV-3.0 LAYOUT
• RACKING: RL UNIVERSAL, SPEEDSEAL TRACK ON COMP,
• ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017.
PV-4.0 ELECTRICAL
SEE DETAIL SNR-DC-00436
M 0 U
• ADD NEW 200A MAIN BREAKER TO SUB -PANEL.
• PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY
ASP
SUB -PANEL -SNR MONR
UNT &SKIRT
PV-5.0 SIGNAGE
GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35.
• MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.
Fol
PV LOAD CENTER :m,:
�.� CHIMNEY
• INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741.
S
SUNRUN METER
• CKING CONFORMS TO AND IS LISTED UNDER UL 2703.E
ATTIC VENT
• SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE 11
s
DEDICATED PV METER :n�� FLUSH ATTIC VENT
MODULES, ARE CLASS A FIRE RATED.
0 PVC PIPE VENT
RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL
NV
F
INVERTER(S) 01 METAL PIPE VENT
CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1).
20 T-VENT
AC
• CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G).
AC DISCONNECT(S)
,
`• ° � SATELLITE DISH
• ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT.
DC
DC DISCONNECT(S) 7_7
• 11.14 AMPS MODULE
IEEII
FIRE SETBACKS
SHORT CIRCUIT CURRENT.
• 17.4 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (A) & 690.8 (B)].
CB
IQ COMBINER BOX HARDSCAPE
F 7
INTERIOR EQUIPMENT — PL— PROPERTY LINE
L
SHOWN AS DASHED
__1
SCALE: NTS
A
AMPERE
i sunrun
AC
ALTERNATING CURRENT
AFCI ARC FAULT CIRCUIT INTERRUPTER
gp� AZIMUTH
E M M
DRESS
ENGINEER22BUSH SD, SUITE 1400
SAN FRANCISCO, CA 94104
P: 949-383-0993
VICINITY MAP
COMP
DC
COMPOSITION
DIRECT CURRENT
EC13007964
(E)
EXISTING
5208 TAMPA W BLVD, TAMPA, FL 33634
ESS
ENERGY STO GE SYSTEM
NE
F X 0
FAX D
EXT
EXTERIOR
INT
INTERIOR
CUSTOMER RESIDENCE:
MAG
MAGNETIC
AMAURY PEREZCOMPANIONI
MSP
MAIN SERVICE PANEL
39962 HARMON GROVE CT,
IN)
NEW
ZEPHYRHILLS, FL, 33540
NTS
NOT TO SCALE
OC
ON CENTER
TEL. (786} 328-2964
�1j11\BBilii!/,/
I) A, (/f`/6j/,,,
PRE-FAB PRE -FABRICATED
APN:24-26-21-0110-00000-2070
\ N F l q�G�,,�
PSF
PV
POUNDS PER SQUARE FOOT
PHOTOVOLTAIC
PROJECT NUMBER:
802R-962PERE
RSD
RAPID SHUTDOWN DEVICE
_ No.85111$ s
TL
TRANSFORMERLESS
DESIGNER: (415) 580 6920 ex3
TYP
TYPICAL
STATE OF i
V
VOLTS
DANIEL KNUDSON
�o % �4�
W
WATTS
SHEET
REV
NAME DATE COMMENTS
COVER SHEET
/ps PO N A I-
1
EXPIRES: 2/28/2023
REV: Al 9/9/2022
signed: 09/9/2022
PAGE
SITE PLAN - SCALE = 1116"° = V- "
■
\\\\1t#IIII//,,
o 923 _
a
STATE F 9> Z
L
t 2122
G�
C>
fit,
ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA
Name Type Height Type Max I OC Detail Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD: 3 PSF
Span Spacing OC Spacing Overhang OC Spacing Overhang NO LOAD: 0 PSF
RL COMP, SEE DETAIL SNR-DC-00436 oUNIVERSAL, SPEEDSEAL TRACK ON ll WIND SPEED:
AR-01 COMP SHINGLE - RLU 1-Story 2X4 PRE -FABRICATED TRUSSES 81 - 11" 24'l 6' 2'- 4" 4'- 0" 2'- 0" STACKED 138 MPH 3-SEC GUST.
S.S.LAG SCREWS:
RL UNIVERSAL. SPEEDSEAL TRACK ON 5116"x4.5": 2.5" MIN EMBEDMENT
AR-02 COMP SHINGLE - RLU 1-Story 2X4 PRE -FABRICATED TRUSSES 4'- 8" 24" 6'- 0" 2'- 4" 4' - 0" 2'- 0" STACKED
COMP, SEE DETAIL SNR-DC-00436 STRUCTURAL NOTES:.
INSTALLERS SHALL NOTIFY
D1 - AR-01 - SCALE: 1/8" = V-0" ENGINEER OF ANY
AZIM: 237' 14'-7' 6'-2" 64" POTENTIAL STRUCTURAL
PITCH: 23'
ISSUES OBSERVED PRIOR
j TO PROCEEDING W/
INSTALLATION,
IF ARRAY (EXCLUDING
SKIRT) IS WITHIN 12"
BOUNDARY REGION OF ANY
10'-10"
ROOF PLANE EDGES
(EXCEPT VALLEYS), THEN
ATTACHMENTS NEED TO BE
ADDED AND OVERHANG
REDUCED WITHIN THE 12"
BOUNDARY REGION ONLY
AS FOLLOWS:
B
ALLOWABLE ATTACHMENT
SPACING INDICATED ON
PLANS TO BE REDUCED BY
5%
- Fol
6'TYP 0
ALLOWABLE OVERHANG
INDICATED ON PLANS TO
BE 1/5TH OF ALLOWABLE
V-2"
ATTACHMENT SPACING
7'- 10" INDICATED ON PLANS
D2 - AR-02 - SCALE: 1/8" = V-0"
AI: 147'
PITCH: 22' sunrun
ENGINEER ADDRESS
- - - - - - - - - - - - - - - - - - - - - - S_ - - - - - - - - - - - - 225 BUSH SUITE 1400
SAN FRANC ISCD CA941GA
P 94lA,M_Q993
EC13007964
ATTACHMENT ALTERNATE OPTION
5208 TANIPAA" BLVD. TAMPA,.-L 33534
DECK MOUNT DETAIL: SNR-DC-00453 PHiON ' E C'
ATTACHMENT SPACING 1 OVERHANG FAX
Portrait: 2'- 0"/0'- 6"
Landscape: 3'- 6"/0'- 6" CUSTOMER RESIDENCE:
14'- 10" 1 ATTACHMENTS PATTERN = STAGGERED AMAURY PEREZCOMPANIONI
T 39962 HARMON GROVE C
OFFSET ATTACHMENTS V-0" WTUIRQ
ZEPHYRHILLS, FL, 33540
#14 S.S.WOOD SCREWS I\A EW
INTO DECK ETEL. (786) 328-2964
i
E3 � s rNo 84923 APN: 24-26-21-0110-00000-2070
61 TYP PROJECT NUMBER:
6-1 ill F
'A 'Z 802R-962PERE
4tj
jp�
DESIGNER: (415) 580-6920 ex3
/NAI
0 DANIEL KNUDSON
E FN I A,_
SHEET
LAYOUT
8'-7" 24'-10"
REV: Al 9/9/2022
PAGE PV-10
Y
UTILITY
GRID
FACILITY '—
LOADS
(N) 35A PV _\
BREAKER AT .—
OPPOSITE END
OF BUSBAR
s
Y •
N 0110".-MR1910NIIIIIIIIIIIIIIIII
LOCKABLE
BLADE s
NEW 200A SQUARE D
'—
MAIN DU222RB
BREAKER 3R, 60A,2P
120/240VAC
FACILITY
'ROUND
EXISTING
—a ®—
200A SUB
PANEL
CONDUIT SCHEDULE
#
CONDUIT
CONDUCTOR
NEUTRAL GROUND
1
NONE
(4) 10 AWG PV RE
NONE (1) 6 AWG BARE COPPER
2
3/4" EMT OR EQUIV.
(4) 10 AWG THHNITHWN-2
NONE (1) 8 AWG THHNITH -2
3
3/4" EMT OR EQUIV.
(2) 8 AWG THHN/TH -2
(1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/TH -2
E
EXISTING
EXISTING
EXISTING EXISTING
JUNCTION BOX PV MODULES
OR EQUIVALENT HANWHA Q-CELLS: Q.PEAK DUO BLK
+ /l M L-G 10+ 400
(19) MODULES
V OPTIMIZERS WIRED IN:
(1) SERIES OF (11) OPTIMIZERS
(1) SERIES OF (8) OPTIMIZERS
SOLAREDGE POWER OPTIMIZERS
P401
-
r w�+►
OPTIMIZER
OPEN CIRCUIT VOLTAGE:
45 3 V INPUT VOLTAGE:
8 VDC
MAX POWERMIN
VOLTAGE:
MAX INPUT* ,
*0 VDC
SHORT CIRCUIT CURRENT:
Y
11. 14 A
MAX OUTPUT CURRENT:
15 ADC
- fi
i TT
SYSTEM OPEN CIRCUIT VOLTAGE:
11 V
SYSTEM OPERATING VOLTAGE:
380 V
MAX ALLOWABLE DC VOLTAGE:
{ VV..
SYSTEM OPERATING CURRENT:
a
i
SYSTEM SHORT
A. V 11
p No. 85119
STATE OF
�p e 044
FI 0 R
EXPIRES: 2/28/2023
signed: 09/9/2022
LABEL LOCATION:
DISCONNECT(
• ;
.•r
• •
PER OD 2019:
0 . 0
LABEL LOCATION:
PHOTOVOLTAIC AC COMBINER (IF
APPLICABLE),
;s r • r
r
SOURCES:,
f' PV SOLAR
SYSTEM
LABEL LOCATION:
UTILITY SERVICE METER AND MAIN
SERVICE PANEL.
PER CODE(S): CEC 2019: 705.12(B)(3), NEC
2017: 705.12(B)(3)
LOCATION:LABEL
-•- s -•-s •.s ;
c• •
.r
LABEL LOCATION:
INTERCONNECTION.
PER s r • . r r
Q
LABEL LOCATION:
INVERTER(S), DC DISCONNECT(S).
PER CODE(S): CEC 2019: 690.53, NEC 2017: 690.53
LOCATION:LABEL
INSTALLED WITHIN TOFRAPID SHUT DOWN
r .•r r 0
r 0
-•• 1r s•
SVVITCH TO •
•• • s•
SHOCK
LOCATION:LABEL
CONNECTED,ARE
PER ; r , . r
•r
13
SIGNS —MAID• V•BELS SnALL rTlEET TnE REQlIF?MTfMl; r
REQUIRED110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE BY SECTION .•r OR
IF REQUESTED BY LOCAL
• SIGNS s LABELS SHALL ADEQUATELYOF HAZARDS USING EFFECTIVE
AFFIXEDWORDS, COLORS AND SYMBOLS.
• LABELS SHALL BE PERMANENTLY EQUIPMENT OR WIRING
METHOD AND SHALL NOT BE HAND WRITTEN.
61 ' L TT TCIFIVM-I;MLIIPI
SIGNS • LABELS SHALL COMPLY WITH ANSI Z535.4-201 1, PRODUCT
SIGNS s LABELS,OTHERWISE SPECIFIED.
s; NOT COVERLABELS.
�110%1111s1r1/1/1/ i
k.
s No,85111
STATE OF f
LpORi?,���v��
�O NM- C 1J��
EXPIRES: /28/2023
signed: 09/9/2022