HomeMy WebLinkAbout22-5199Uft-y—&-Ze ph yrh i I IS 5335 Eighth Street Zephyrhills, FIL 33542 Phone: (813) 780-0020 Fax: (813) 780-0021 ELCMISC-005199-2022 Issue Date: 11/14/2022 REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. I 11MIRWIF11 111!11 111111 1 � :1 11 1111 11 , a 0 WOMEN= ZTIMMZMi = 2320911= . # ; TMT-Tr��� Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNATURE Fy PE IMIT OFFICEV 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department 1W Owner's Name a Phone Number KOMI Owner's Address t-11A) V46S 0 IT, 1) V. Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address F- JOB ADDRESS 5 now'soo (%Tc 1Y. LOT SUBDIVISION n P� IA Rl PARCELID#[� -0100 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR F--] ADD/ALT SIGN DEMOLISH INSTALL REPAIR PROPOSED USE E;2] SFR COMM OTHER TYPE OF CONSTRUCTION BLOCK FRAME STEEL DESCRIPTION OF WORK tI t4min poot inuali itw, ruiourraw qsirxir Il BUILDING SIZE SQ FOOTAGE HEIGHT BUILDING 1$ (2 1-71Qq� VALUATION OF TOTAL CONSTRUCTION EbELECTRICAL AMP SERVICE 0 PROGRESS ENERGY W.R.E.C- =PLUMBING 1$ —1 =MECHANICAL VALUATION OF MECHANICAL INSTALLATION =GAS ROOFING SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY e,...._.. ___ xs r 9 t' SIGNATURE REGISTERED Y/N FEE CURREN Address 4Zz e- 7-0y- 40 License # 3 ELECTRICIAN COMPANY = SIGNATURE REGISTERED --FEE —CURREN --- Address License #_� PLUMBER COMPANY SIGNATURE REGISTERED Y/N FEE CURREN L_X1 N _J Address License# �m� MECHANICAL COMPANY SIGNATURE REGISTERED N FEE CURREN E= Address License III OTHER COMPANY SIGNATURE REGISTERED [_Y±_Nj FEE CURREN L_YLN_j Address License # RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Sift Fence installed, Sanitary Facilities & 1 dumpster, Site Work Permit for subdivisions/large projects COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction. Minimum ten (10) working days after submittal date- Required onsile, Construction Plans, Stormwater Plans wt Sift Fence installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction, 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contracter(s) sign portions of the 'contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County, TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant, have been provided with a copy of the 'Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner' prior to commencement. CONTRACTOR'SIOWNFR'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection -Cypress Bayheads, Welland Areas and Environmentally Sensitive Lands, WaterANastewater Treatment. Southwest Florida Water Management District -Wells, Cypress Bayheads, Welland Areas, Altering Watercourses. Army Corps of Engineers -Seawalls, Docks, Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency -Asbestos abatement. Federal Aviation Authority -Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be Submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida, - If the fill material is to be used in Flood Zone 'A:' in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. if use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. 01, •1 - . 0 1 , go 4ff 91111ii-AFFLEIMEOM- OWNER OR AGENT CONTRACTOR-__=;-� I Subscribed and sworn to (or affirmed) before me this So Q,,ye this A I Iscri d and swom to (or affirmed) hater _b 114?11j��by Who is/are personally known to me or has/have produced Who islare aer.S222��e or has/have produced as identification. personally as identification. Notary Public Notary Public Commission No. Commission I d44c11c, Name of Notary typed, printed or stamped Name of Notary typed, printed or stamped o_JT EXD PPAIIBRREEEL SSL..: A MMA. rr. ddVitA �4L, E 2N0T21I,Nsee.� M COMMISSION GG 3075 07 Bonded That Notary Public t U=ndenvrltanA Q117425 Bridge Hill Ct. Tampa, FL 33647 0v, License # E130013 P7w,f­,m Softf Tel. # (813)-565-1443 Property Owner Info: Hector Roman 39555 Dawson Chase Dr Zephyrhills, FL 33540 Inverter: Pal Module: Rail: System Wattage Roof Material: Wind Load: Fastener(s): 3 =� Ac, u, n Chimney Utility Meter ro Satellite PV Disconnect Vent Pipe Aerial Compass Reference Enphase IQ8PLUS-72-2-US (43) Canadian Solar CS3U-39OMS Sunmodo 16.770W Composition Shingles R-4 21 to 27 Deg # Mod (1) 5/16" x 4-3/4" or Pitch: (4) #14 x 3" Lags Azimu S-1 Site Details S-2 Mounting Equipment S-3 Mounting Plan E-1 Line Diagram E-2 Electrical Code N-1 Project Notes Date: 10/28/2022 Drawn by: DL Revised ---- Rev #,. Rev Page: S-1 General Notes: -Enphase IQ8PLUS-72-2-US Micro Inverters are located on roof behind each module. -First responder access maintained and from adjacent roof, -Wire run from array to connection is 40 feet. Requirements Met: -2020 Florida Residential Code & FBC, 7th Edition (2021 International Residential Code) - 2nd Printing modified by the FL Building Standards -2020 Florida Building Energy -Conservation Code 7th edition -City of Zephyrhills Code -2017 National Electric Code -2021 International Building Code -2015 International Energy Code -2021 International Fire Code Chad Widup, P.E. 39905 Grays Airpod Road Lady Lake, FL 32159 P.E. No. 60302 36" Pathway R_ 1 # Modules (21) Pitch: 240 Azimuth-, 2700 '16" Pathway Systemnneets the requirements effNITTA" 70,11, T-'-';�l tion, Chapter 11, 12 Meets All Editions of Florida Fire Prevention Code 2020 7th Edition Meets all requirements of NFPA-1 7th Edition and NFPA-101 1st Responder Access minimum of 36" unobstructed as per Section R324 of the 2020 IRC Ground Access Points are a minimum of 36" x 36" AC Disconnect will be Visible, Lockable, Labeled, Accessible and within 10ft of the Utility Meter. -3 Modules (15) itch: 240 ,zimuth: 900 ­100 En,,phase Cornbiner Box -am Non -Fused PV Disconnect ­o titflfty Meter -Main Combo les (4) 40 Azimuth: 1800 F R, 0%�' IN T rl F HI 0 IU S E Layoudt Subject to Change Based on Site Con6tions Qlov� ,ransfimrn &Mar POWER Property Owner Info: 17425 Bridge Hill Ct. Tampa, FL 33647 License # EC13008213 Tel. # (813)-565-1443 TONY COOPER 2590 GRANADA CIR E ST PETERSBURG, FL 33712 Inverter: PV Module: Rail: System Wattage Roof Material: Wind Load: Fastener(s): Enphase IQ8PLUS-72-2-US (44) CS1Y-400MS Iron Ridge XR-10 17,60OW Composition Shingles 8 to 20 Deg (1) 5/16" x 4-3/4" or (4) #14 x 3" Lags 2020 FBC Roof Mounted PV Design Criteria: ® Height: 15' in Speed(Vult): 150mph 3 sec gust -Exposure Category: C -Designed as per ASCE7-16 -Snow Load: Opsf Date: 10/27/2022 Drawn by- FL Revised byw ---- Rev #: ---- Rev Date -,---- Page: S-3 Chad Widup, P.E. 39905 Grays Airpod Road Lady Lake, FL 32159 P.E. No9 60302 14' Iron Ridge XR-10 Rail 17' 1001ROMMENOWNHURVANKEEN 16 MUNLIMMITMOMEWASAMMMM WMIN RAN N 41 14 110 100 24 2 6 44 44 1 4 1 0 31 — �01 -1 Splice Bar ci Sunmodo an Mounts Iron Ridge UFO's Iron Ridge Sleeves/End Caps Roof Top Combiner Iron Ridge Ground Lugs CS1Y-400MS Enphase IQ8PLUS-72-2-US Enphase Combiner Box 20A 2P Breakers 100A Fused Disconnect 70A Fuses No Exposed or Edge Placements Allowed Mi All max cantilevers per manufacturer spec, Max Cantilever = Max Span * (13) Plans satisfy zones F-B& 1111-5,11,11 0,7, 1 im Mount Attachment locations Ir­�stail will be do,ne 1[o Manufacturer Spec R-1 # Modules (24) Pitch: 180 Azimuth: 2150 # Modules (20) Pitch: 180 Azimuth: 351 Rafter Zone 1: Max Span = 48" Max Cantilever = 16" Zone 1: Zone 2e: Max Span = 48" Max Cantilever = 16" Max Span = 24" Zone 2n: Max Cantilever = 81' Zone 2r: Max Span = 24" Max Cantilever = 8" Zone 3e: Max Span = 24" Max Cantilever = 8" Zone 3r: Max Span = 24" Max Cantilever = 8" Max Span = 24" Max Cantilever = 8" Zone 2e: Max Span = 24" Max Cantilever = 8" Zone 2n, No mounts to be isntalled Zone 2r: No mounts to be isntalled Zone 3e: No mounts to be isntalled Zone 3r: No mounts to be isntalled 1742 ridge Hill t. Label dire Type V�ire Size (A�IC�) Ground (A te) Min. Conduit Size; Overcurrent Protection Crevice (OCP®) Calculation L 33647 AC Cable & Bare Copper 12 N/A License 13008213Max AC Output Current 1.21A r a*g Tel, (13)-565-1443vo. NM-B Cable 12 12 /4"- of Inverters 44 Oas, ,.�. — — — gq�y��j 9 L Total Output Current 53.24A ® TH H N 4 N/A 1,a �� �r �� Info: Total * 125°�� 66o55A OCPD Size 70A TONY COOPER Conductor Size #4AWG No. Current Carrying Conductors <4 ST , FL 33712 Photovolaice Inverters Enphase IQ8PLUS-72-2-US (44)CSlY-40OMS Pv Module: (44) CS1Y-400MS Systems Wattage: 17,50 Inverters: (44) Enphase I 8 LUS-72-2-US Micro Inverters Circuits: Noted (2) circuits of (10) Inverters -All wiring to meet the 2017 NEC and (2) circuits of (12) Inverters Florida electric codes. -Type of conduit to be determined Maximum Inverters Per 20A Circuit (13) on site by contractor. Number of rooftop Junction Boxes to be determined on site and are at least MA � - - 3R rated. -AC Disconnect will be visible, lockable, � - labeled accessible, and located within loftRooftop of Utility Meter. Junction -12-2 Romsex may be used for interior y Box Line Side Tap building and attic runs only. 12-2 Rornex not to be used in conduit or outdoorEXTSTING environments. Maus Service Parcel 150A Maus breaker :Date.- 10/27/2022 Enphase by: FL Combiner Box x Manw _Gcxe _Drawn Revised by-, — — — — (1) - 20A Breaker Per Circuit soon rased Pi/ AC DisconnectRev ®� o, 4 Circuits (2) 70 Fuses Neutral (1) 10/15A Breaker sary eround Rat dEond for Envoy Page: E-1 240v 125A Rated Disconnect---, '" All conditions for NEC 312.8 referring to taps in over current device enclosures must be met 17425 Bridge Hill Ct. Tampa, FL 33647 ( 171000V License # EC13008213 POWER Tel. # (813)-565-1443 Property Owner Info: TONY COOPER 2590 GRANADA CIR E ST PETERSBURG, FL 33712 Inverter: Enphase IQ8PLUS-724-2-US PV Module:(44) CSlY-400MS System Wattage: 1.7,60OW Note: -Subject PV Systems has been designed to meet the requirments of the NEC 2017, and those set forth by the Florida Solar Energy Center Certification, Including Maximum Number of Module Strings, Maximum number of modules per string, Maximum Output, Module Manufacturer and model number, inverter manufacturer and model number, as applicable. -All wiring to meet the 2017 NEC and Florida electric codes. 100A Disconnect -Type of conduit to be determined on site by contractor. Datem. 10/27/2022 Drawn by: FL Revised by: Rev Date Page-, E-2 Chad Widup, P.E. 39905 Grays Airpod Road I Lady Lake, FL 32159 P4E. No0 60302 Combined Inverter Output Design Temper aLure (OF) 94 Max Ambient Temperature Range (OF) 87-95 310.15(B)(2)(a) Conductor Ternp Rating (OC) 90 # of Current Camlying Conductors I I <4 310AS(B)(3)1(a) Max AC_ Output C urrent, # of Inverters 44 Total Output Current 53.24k 690.8(A)(3) Total * 125% 66-55k 690.8(B)(1) Ocpbsize 70A Ambient Temp Correction Factor 0.96 310.15(B)(2)(a) Raceway Fill Adjustment Factor 100% 31OA5(B)(3)(a) Conductor Allowable Ampacity 95A Conductor Adjusted Arnpacity 91.2A 95A*O96=91,2A Equipment Temperature Arnpacity Limitation Conductor, Temp Rating (OC) 75 OCPD Size 10A Conductor Size 4AWG Conductor Allowable Ampacity 85A Ca,n6ador,', :,ized' to Coo�dinate 'vvitn, the lowest lemperalure raftJrng of any connecled termination, conducu'­�r, or devke, TE,q7p�'­-jtore - ft)r the - fio-erneendor ed equipirn, erit to be 751C_ Side Tap will be don-.. in Kain Service, Panel adjacent to U-ne D UtHity mi,"'ter Comb�ner box In cornpliance Per Code NEC 705,12 4* 20A < 125A No other loads to be adde NECM,*CXI) AND WPA1,11,12,21 111,11,1221.4 318 IN MIN. TEXT TURN RAPID SHUTDOWN SWITCH TO 3/16 IN MIN. TEXT THE "OFF POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. RATED AC OUTPUT GURRENT� 53,24A NOMINAL OPERATING VOLTAGE: 240VAC NEC LABEL NOTES: 1, THE WARNING SIGN(S) OR LABELS} SHALL COMPLY WITH NEC 110.21(8) 2. LABELS SHALL BE SUITABLE FOR THE ENVRONMENT WHERE THEY ARE INSTALLED. 3, LABELS TO BE A MIN LETTER HEiGH T OF 3/8' AND PERMANENTLY AFFIXED, 4, LABELS SHALL ALSO COMPLY WITH THE SPECIFIC REQUIREPAE,NTS OF THE AUTHOR! TY HAVING JURISDICI !ON, THIS SERVICE METER IS ALSO SERVED BY A HOTOVOLTAIC SYSTEM 705.12(B)(3) NEC 690.31 (G)(3) MIN= DUAL POWER SUPPLY SOURCE& UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM INVERTER OUTPUT CONNECTION: DO NOT RELOCATE THIS OVEROURRENT DEVICE POWER SOURCE OUTPUT CONNECTION:: DO NOT RELOCATE THIS OVERCURRENT:: DEVICE Main Service Disconnect lab, d shl,­ffl vwith /,,ftte capkal at least 3 ' 4 In, In heigh Mt an'd m' a nonsedf font, -aler' Jals -,.Ised 'cn Une label shw! be refledMe, vvealher resistant, and sullable f0'r the enMror"'men" PV Disconnect and otCher equiipment -11he iabei shafl be r d Y-Jih,, vAote capil, ers a� ieast _JV8 in, in height anal ln a nonse,if �ont. -Materials used'. for ffie iabe� si",all be reflectwe, weather res�staint., and suitable for the enwronnlerft,