Loading...
HomeMy WebLinkAbout22-5211 (2)it of Zephyr hill s 5335 Eighth Street Zephyrhills, FL 33542 FIRE- 005211-2022 Phone: (813) 780-0020 Fax: (813) 780-0021 Issue Date: 07/18/2023 34 25 21 0160 00000 0010 k1111 lit 7, _g Name: ZEPHYRHILLS PLAZA LLC Permit Type: Fire I I Class of Work: Fire Alarm Address: 5236 Commerical Way STE F SPRING HILL, FL 34606 Building Valuation: $32,750.00 Electrical Valuation: Mechanical Valuation: Plumbing Valuation: Total Valuation: $32,750,00 Total Fees: $170.00 Amount Paid: $170.00 Date Paid: 7/18/2023 9:32:21AM !INSTALLATION FIRE ALARM REPLACE *** I X REINSTATE 7431 Gall Boulevard Fire Alarm System Plan Review $50.00 Re -inspection Fee $25.00 Fire Permit Fee 50- $50.00 Acceptance Inspection Test $45.00 . . . . . . . . . . "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for I ; 11 71W&-*n1=b A=77, accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. A� i�mffi __ Raw! P IT OFFICE EF r—, Nuffing: City of Zephyrhills 5335 Eighth Street Zephyrhills, FL 33542 Phone: (813) 780-0020 Fax: (813) 780-0021 ,!FIRE-05211-2022 I I !Issue Date: REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall Impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice fol Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNATURE PEIMIT OFFICE0 V , 'Al 'M0011111W] — 111,111111,1011. IM:M"11101 Mi W I � a INSTR#2022265604OR BK1 0 74' 1 PG1637 Page 1 of 1 12122/2022 10:05 AM Rcpt: 2534937 Rec: 10,00 DS: 0.00 IT: 0-00 Nikki Alvarez-Sowles, Esq., Pasco County Clerk & Comptroller Permit Number Parcel ID Number 34-25-21-0160-00000-0010 I NOTICE OF COMMENCEMENT State of Florida County of Pasco THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Section 713.13 of the Florida Statutes, the following information is provided in this NOTICE OF COMMENCEMENT. 1. Description of property (legal description of property)Retail Farming Supplys a) Street (job) Address: Tractor Supply-545 7431 Gall Blvd, Zephyrhills 2. General description of improvements: Remodel. Adding Garden Center, Replacing Fire Alarm 3, Owner Information or Lessee information if the Lessee contracted for the improvement: a) Name and address: ZEPHYRH ILLS PLAZA LLC 5236 COMMERCIAL WAY STE F SPRING HILL, FL 34606-1995 b) Name and address of fee simple titleholder (if different than Owner listed above) c) Interest in property: Owner 4, Contractor Information a) Name and address: Johnson Controls Security Solutions 3802 Sugar Palm Dr Tampa Fl 36612 b) Telephone No.: 813 442 3293 Fax No.: (optional) 5. Surety (if applicable, a copy of the payment bond is attached) a) Name and address: Fax Number: b) Telephone No.: c) Amount of Bond: $ 6. Lender a) Name and address: b) Telephone No.: notices or other documents may be served as provided by in 7. Persons within the State of Florida designated by Owner upon whom Section 713.13 (1) (a) 7, Florida Statutes: a) Name and address: Fax No.: (optional) b) Telephone No.: 8 a)] n addition to himself or herself, Owner designates of to receive a copy of the Lienors Notice as provided in Section 713.13 (1) (b), Florida Statutes. b)Phone Number of Person or entity designated by Owner: 9. Expiration date of notice of commencement (the expiration date may not be before the completion of construction and final payment to the contractor, but will be 1 year from the date of recording unless a different date is specified): _,20- WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOT CE OF COMMENCEMENT. Under p I , perjury, ec re that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of my kno a and Steve Ausdennnoore Director of Construction Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager Print Name and Signatory's Title/Office The foregoing instrument was acknowledged before me this ..... 15th day of December 20_2_2_ by Steve Ausclenmoore as the Director of Construction (type of authority e.g. officer, trustee, attorney in fact) for Tractor Supply Co. as Lessee (name of person) (type of authority,. -e.g. officer, trustee, attorney in fact) ume inst in rument was executed ���® VIENN�'I, �.....,. 01", for _Zephyrhins Plaza LLC. name of behalf ofw Signature of Notary Public lip Personally Known X or Produced ID_ Type of ID N/A Print, Name of Notary Penny Da Public/Commission Number State Of Flotida, County Of Pasco 7 It, - This is to certify that the foregoing is a true and correct copy of the document on file or of public record in this office. t. Witness my hand and official seal this day of Nikki Alvarez-Sowles, Esq., Clerk & Comptroller le - Pasco County, Florida BY Deputy Clerk 813-780-0020 Owner's Address 1:2 ; 6'Cc� ttvy;vc', ,�p k", I v C, H I 11 , T7 T Tii Fee Simple Titleholder Name City of Zephyrhills Permit Application Fax-813-780-0021 Building Department I Phone Contact for Permitting �3 11L Owner Phone Number Owner Phone Number Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 0% LOT # SUBDIVISION PARCEL I D#11 CV 6 o -0000u, cN o/ o (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CDNSTR INSTALL e ADD/ALT SIGN DEMOLISH REPAIR PROPOSED USE SFR COMM OTHER TYPE OF CONSTRUCTION BLOCK FRAME STEEL , & DESCRIPTION OF WORK _L _0 /s I t , '7' -, ( , 10 rt BUILDING SIZE FOOTAGE' HEIGHT x E21BUILDING 7 pVALUATION OF TOTAL CONSTRUCTION =ELECTRICAL AMP SERVICE PROGRESS ENERGY W.R,E.C. =MECHANICAL =GAS ROOFING FINISHED FLOOR ELEVATIONS I K/ VALUATION OF MECHANICAL INSTALLATION SPECIALTY OTHER Fh FLOOD ZONE AREA =YES NO (9 BUILDER COMPANYY111"I"-Ulut" Je�_ va�v- ;1­3 L, 7!; �Alj 4 A; t SIG RE 11 13NATURE GISTERED1 Y/N FEE CURREN YN Address t P/,— 'Ur*emsLicense # F2 6 0 be,) J-5 0 ELECTRICIAN COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Address License # PLUMBER COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address License # MECHANICAL COMPANY SIGNATURE REGISTERED Y/N FEE CURREN LY/N Address License # OTHER COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address License # RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects I COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms, R-O-W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (AIC upgrades over $7500) — Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage) Driveways -Not over Counter if on public roadways..needs ROW 10/25/22, 2:41 PM tyco seculit'v P 0 r I a Cust # 117426834, Job #26 TRACTOR SUPPLY COMPANY ZEPHYRHILLS, FL33541 Scope Of Work System Operation TSC will be adding a Garden Center and remodeling the interior of the store. A custoly preconstruction site walk with GC is required. Please refer to attached documents. Please return to COE. JCI to remove existing FA system and install a new Simplex 4007 system, Install new Simplex 4007 and new initiating and notification devices per attached plans. Existing Cellular communicator will be re -use with the new Simplex system for sole path cell. Unplug the phone line(s) that were being used for communication on the existing system from RJ3 I X Jacks on the wall (if applicable) Existing duct detectors and test switches to remain and be reused. JCI will provide connection monitor the ducts. Please refer to attached drawings FIRE ALARM SYSTEM UPGRADE. THIS NEW SYSTEM WILL INCLUDE: � SMOKE DETECTOR ABOVE THE FIRE PANEL. - MANUAL PULL STATIONS WITHIN YOF EGRESS DOORS. - CEILING HORN STROBES AND STROBES SHALL BE INSTALLED THROUGHOUT THE FACILITY. - WALL STROBES SHALL BE INSTALLED IN RESTROOMS AND SMALL AREAS, - WEATHERPROOF HORN STROBE TO BE INSTALLED OUTSIDE ABOVE FDC. - WEATHERPROOF HORN STROBE TO BE Traini INSTALLED OUTSIDE AT THE GARDEN CENTER. - END OF LINE RESISTORS PROVIDED WITH PANEL AND MONITOR MODULES.. NO EXTRA RESISTORS PROVIDED. - PRIOR TO INSTALLATION OF ANY SYSTEM COMPONENT, INSTALLATION TECHNICIAN SHALL CONFER AND COORDINATE WITH THE GENERAL CONTRACTOR AND ALL OTHER APPLICABLE TRADES TO ENSURE INSTALLATION LOCATION WILL NOT CONFLICT WITH OTHER TRADES. THE NEW Docui FIRE ALARM SYSTEM SHALL MONITOR & CONTROL ALL INITIATING DEVICES & NOTIFICATION APPLIANCES. THE NEW FIRE ALARM SYSTEM SHALL ALSO MONITOR SPRINKLER SYSTEM & EXISTING DUCT DETECTORS. THE NEW FIRE ALARM SYSTEM SHALL COMMUNICATE TO THE MONITORING STATION VIA A EXISTING EXTERNAL SOLE PATH CELLULAR DIALER. FIRE ALARM Gei COMMUNICATOR PRIMARY AND BACK-UP POWER IS PROVIDED BY THE FACP THIS BUILDING IS PARTIALLY SPRINKLERED, UPON AHJ ACCEPTANCE OF THE NEW SYSTEM, THE EXISTING SYSTEM SHALL BE REMOVED. MR2127r= Existing Tractor Supply Store. - Lift will be required due to working heights. Panels will be factory programmed Existing Equipment Existing FA system will be upgraded with new Simplex. Existing conduit, and back boxes can be re -used if in good condition. Customer Response Customer to provide 120 VAC connections. https.//ftp.tycois.com/job/sow/12911660 1/2 TRACTOR SUPPLY COMPANY #0545 GIBBENS R * F SyrRAYTOWN, t ENGMERING ' I 1 . Prepared a JOHNSON CONTROLS INTERNATIONAL 1200 E. EXPOSITION AVE., AURORA, COLORADO81 0 Fire Alarm Control Panel & Panel Components 1 4007-9101 IFIRE ALARM CONTROL PANEL 2 4606-9202 FIRE ALARM ANNUNCIATOR 3 SSU00672 IFIRE RECORDS DOCUMENT BOX Initiating Devices 4 4098-9714 INTELLIGENT PHOTO SMOKE DETECTOR 5 4099-9006 INTELLIGENT MANUAL PULL STATION Supervising Modules, Relays and Ancilla!jEquipment 6 4090-9001 JINTELLIGENT MONITOR MODULE Notification Appliances HSR MULTI - CANDELA WALL MOUNT HORN STROBE 7 HSRC MULTI - CANDELA CEILING MOUNT HORN STROBE RED STR MULTI - CANDELA WALL MOUNT STROBE 8 STRC MULTI - CANDELA CEILING MOUNT STROBE =9ASWP-2475W-FR MULTI - CANDELA WALL MOUNT HORN STROBE WEATHER-PROOF RED �����m� , � ���~������������� �~� �=������������ oc'ucccsnwListed, FM, NYC Fire oev/xppmved~ 4007ES Hybrid, Fire Detection and Control Unit with Addressable and/or Conventional Initiation Features Compatible with Simplex ES Net and 4120 fire alarm networks Satisfies avariety ofnew and retrofit applications 4.3in. (1U9mm)diagonal color touchocreendisplay: ' Provides detailed system status and point information ' Supports dual language selection, including unicodrcharacter languages ' Acustom background display appears when operation is normal Eight point zone/relay module: ' Each point isselectable asan|D[input nrRelay output, Class A|D[s require two points (one out and one remm);one module isstandard and you can field install uptnthree additional modules for atotal of four Opoint zone/relay modules for each system 'You can configure each point nnthe |DC/Re|aymodule asacontrol relay rated 2Aat30VD[(res|stive}aseither normally open ornormally closed ' Power comes directly from the power supply nrthrough the optional 25VD[Regulator Module ' You can select the |n[end'of-|in+(EOUresistor value from awide range ofresistance values for retrofit convenience Electrically isolated |DNet2 addressable initiating device SLC: ' Provides built-in short circuit isolation for monitoring and control of TrueA|armanalog sensors and |DNetcommunications monitoring and control devices; for use with either shielded urunshielded, twisted or untwisted single pair wiring; outputs are Class AorClass 8 'Standard panel signaling line circuit (SU]provides uprn100 addressable points; optional additional loop expansion modules provide anadditional isolated loop with short circuit isolation for the !DNet2channel; each loop expansion module also provides an additional 75addressable points Power supply: ' Four notification appliance circuits (NACs) selectable asClass AorClass Bwith DAtotal available current ' You can select the NA[ EOL resistor value from a wide range of resistance values for retrofit convenience ' Additional notification power capacity is available using the 4OO9 |DNet NA[Exrender ' Battery backup charging nfupto33 ATupto1DAbfor cabinet - mounted bancriesanduptn33AbhurbanenesmountedUnse nipp|ednemu«ebatterycabinet General mechanical: ' Red nrplatinum cabinet, rated NEWA1 and|P3O 4007ES Listings reference: UL864 Control Units, System (UOJZ); Control Unit Accessories, System, Fire Alarm (UOXX); Control Units, Releasing Device Service (SYZV) ULZ017 Emergency Alarm System Control Units (CO deceuion),(BZ|) UL[-S559 Central Station Fire Alarm System Units <DAYRQ VLC'5527 Control Units, System, Fire Alarm (UCUZ[), Control Unit Accessories, System, Fire Alarm (U0XX[;Control Units, Releasing Device Service (SYZV[) Figure 1: 4007ES Hybrid Unit front view Software feature summary: ' Current and previous panel configuration maintained |non'hoard memory 'Aninternal Ethernet service port isavailable for service computer connections toperform configuration updates, downloads and uploads; report downloads, and update system software ^Internal USBinterface allows amemory stick costore job revisions, update revised jobs and panel software, and save detailed system reports from the panel Optional modules and connections Include: ' Fire alarm network interface card (N|[}for ESNet or4120network ' Peer-to-Peernetwork communications, supports either Class Bnr Class Xoperation ' Point orEvent DA[Tassembly for Connected Services Gateway ' Upootwo additional |DNet2addressable device output loop connections with short circuit fault protection and with 75additional point capacity each ' Front mounted 48 LED annunciator with custom label inserts; LEDs are programmable for upm240[zones o[alarm and trouble annunciation nrother custom annunciation requirements ' Remote LED annunciator support through remote user interface (RUV communications port for use with UTPwiring ' Dual RS-232ports for printer, P[annunciator orthird party inter -face 'Alarm relays and auxiliary relays 'City connections, with orwithout disconnect switch '4O090Ne1NA[Extenders coextend NA[capability for power and distance 'Battery brackets for seismic area protection; see Mechanical descr|p«ionfor more information *This product has beer) approved bythe Cal fommState Fire Marshal (Csnwpursuant mSection ,s1*^/mm°cuxmia*mm`aouSamvcwoaeCsnwLimngr1o5-nmeo37owmmwame values ""wo conditions concerning materia I presented in this document. NYC Fire Dept CCA#6191 A At the time of publication onlyuL and oo/uufigs are. applicable moNet network products. Additional listings may wapplicable; contact your local product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co, are the property wTycoFire Protection Products r^^oz000^ o°, mi�n,o, 4007ES Hybrid, Fire Detection and Control Unit with Addressable and/or Conventional Initiation 4O07ESSeries Fire Detection and Control Units provide extensive installation, operator, and service features with point and module capacities suitable for awide range o[system applications, Panels can beconfigured for stand-alone ornetworked fire control operation. The convenient and intuitive color touchsceenprovides easy access for typical system response actions and for detailed system review or configuration updates with password control uolimit user access. Standard conventional |DCsand addressable |DNez2communications provide flexibility for both new and retrofit systems. |D[and NA[EOL resistor values are selectable comatch awide range ofexisting initiating device circuits and notification appliance circuits. Simplex BNetwork (ES Net) isanext generation |P-basedfire network that uses industry standard network techno|ogyandinfrasouunne,and allows for simplified network upgrades, easy terminal connectivity and |P file transfer between nodes, and advanced network diagnostics, You can upgrade ESfire alarm control units (FA[Us}tooperate onanB network byadding onESNet N|[tnthe panel. Toupgrade anexisting *120network toESNet, you must replace all of the 4120N|[cards onthe network loop with BNet N|[s. Note: E5N|[sand 4120N|[scannot Uemixed nnthe same network loop. For more detailed information onESNet, refer nudata sheet S4/00-0876,and talk toyour local Simplex product supplier. Convenient status information With the locking door closed, the glass window allows viewing of the display status LEDs. The user interface isa43in. (1O9mm)diagonal color tnuchsceenL[Dwith separate status LEDs, see Figure l LED indicators describe the general category ofactivity being displayed and the L[Dprovides more detail. Authorized user can unlock the door mgain access tothe control functions and scroll through the display for additional detail. Convenient and detailed operator information is easily accessible using alogical, menu -driven nvuchsceendisplay with password access control Multiple automatic and manual diagnostics for maintenance reduo\nn Alarm and Trouble History Logs (up zo10OOentries for each, 2UOUtotal events) are available for viewing from the display orfor printing »oa connected printer, ordownloaded toaservice computer Module level ground fault searching assists installation and service by locating and isolating modules with grounded wiring W8LKTESTsilent oraudible system test performs anautomatic self - resetting testqc|eandsuppnnsupcoe|ght WKLKTESTgmups Install Mode allows grouping ofmultiple troubles for oninsc*Ued modules and devices into asingle trouble condition (typical with future phased expansion);with future equipment and devices grouped into asingle trouble, operators can more clearly identify events from the commissioned and occupied areas Figure 2:Toucho,eemdisplay with LED status indicators Main Menu screen provides easy navigation nothe function required. Buttons �B,and [have programmable functions. System Trouble screen identifies active troubles with custom labels displayed, arrows allow navigation through the list. ystemAlarm screen identifies active alarms with custom labels displayed. Use the arrows coallow navigation through the list. Trouble Log screen allows review o[past troubles with time stamp and point details shown. Point Information screen allows User Access Login screen controls review ofpoint details, arrows allow access ^opanel operations as navigation through the information. determined per panel. SIAIE "I Mechanical description ' Locking door with polymrhonate window Latching front panel assembly swings forward for convenient internal access ' Smooth box surfaces are provided for locally cutting conduit entrance holes exactly where required 'Modules are power -limited except asnoted, such asrelay modules 'Battery compartment (b000m) accepts two batteries, uptol8An, to bemounted within the cabinet withoucinterfering with module space; Page S4007-0001 Rev. 185/2021 4007ES Hybrid, Fire Detection and Control Unit with Addressable and/or Conventional Initiation charger capacity is up to 33 Ah; for information about batteries greater than 18 Ah and external battery cabinets, see Module and accessories selection Information Cabinet assembly design has been seismic tested and is certified to IBC and CBC standards as well as to ASCE 7 categories A through F, requires battery brackets, refer to data sheet 52081-0019 for more information The 4007ES Hybrid provides an IDNet 2 addressable initiating device signaling line circuit (SLC) that supervises wiring connections and the individual device communications status on the SLC. With 2-wire IDNet 2 SLCs, initiation, monitoring, and control devices such as manual fire alarm stations, TrueAlarm sensors, control relays, and sprinkler waterflow switches can communicate their identity and status and receive fire alarm system control. Additional addressable interface modules include circuit isolators, conventional IDC zone adapters, and interface to other system circuits such as fans, dampers, and elevator controls. Each addressable device on the IDNet 2 communication channel is continuously interrogated for status condition such as: normal, off -normal, alarm, supervisory, or trouble. Both Class B and Class A operation is available. Sophisticated poll and response communication techniques ensure supervision integrity and allow for T-tapping of the circuits for Class B operation. Devices with LEDs pulse the LED to indicate receipt of a communications poll and can be turned on steady from the panel. With addressable devices, the location and status of the connected device is monitored, logged, and displayed on the operator interface LCD with each device having its own 40-character custom label for precise identification. Addressable initiating device communications include operation of TrueAlarm smoke and temperature sensors. Smoke sensors transmit an output value based on their smoke chamber condition and the CPU maintains a current value, peak value, and an average value for each sensor. Status is determined by comparing the current sensor value to its average value. Tracking this average value as a continuously shifting reference point filters out environmental factors that cause shifts in sensitivity. Figure 3: TrueAlarm Figure 4: TrueAlarm Photo/ Photo Sensor with base Heat Sensor in CO base Programmable sensitivity Programmable sensitivity of each sensor is selectable at the control panel for different levels of smoke obscuration, shown directly in percent, or for specific heat detection levels. To evaluate whether the sensitivity should be revised, the peak value is stored in memory and can be easily read or downloaded as a report and compared to the alarm threshold directly in percent. CO sensor bases CO sensor bases combine an electrolytic CO sensing module with a TrueAlarm analog sensor to provide a single multiple sensing assembly using one system address. You can enable and disable the CO sensor, and you can use it in LED/Switch modes and custom control. Refer to data sheet 54098-0052 for more details. TrueAlarm heat sensors You can select TrueAlarm heat sensors for fixed temperature detection, with or without rate -of -rise detection. Utility temperature sensing is also available, typically to provide freeze warnings or alert to HVAC system problems. Readings are selectable as either Fahrenheit or Celsius. TrueSense early fire detection Multi -sensor 4098-9754 provides photoelectric and heat sensor data using a single IDNet address. The panel evaluates smoke activity, heat activity, and their combination, to provide TrueSense early detection. For more details on this operation, refer to data sheet 54098-0024. TrueAlarm operation allows the FACU to automatically indicate when a sensor is almost dirty, dirty, and excessively dirty. The NFPA 72 requirement for a test of the sensitivity range of the sensors is fulfilled by the ability of TrueAlarm operation to maintain the sensitivity level of each sensor. CO sensors track their 10 year active life status providing indicators to assist with service planning. Indicators occur at: 1 year, 6 months, and end of life. Modular TrueAlarm sensors TrueAlarm sensors use the same base and different sensor types (smoke or heat sensor) and can be easily interchanged to meet specific location requirements. This allows intentional sensor substitution during building construction when conditions are temporarily dusty. Instead of covering smoke sensors causing them to disable, heat sensors may be installed without reprogramming the FACU. The FACU will indicate an incorrect sensor type, but the heat sensor will operate at a default sensitivity to provide heat detection for building protection at that location. .. .•Mm= = The 4007ES Hybrid provides an isolated output IDNet 2 SLC that supports up to 250 addressable monitor and control points intermixed on the same pair of wires. 250 total requires two 4007-9803 IDNet 2 loop expansion modules. Table 1: IDNet 2 SLC wiring specifications Maximum distance 0 to 125 14000 ft (1219 ni 50 ohms from control panel for 126 to 2500 ft (762 m); 35 ohms each device load 250 !Up to 12,500 ft (3.8 km); 0.60 pF T-taps for Class 8 wiring Maximum capacitance between 1 F IDNet 2 channels p Loading for each device 0.8 mA supv., 1 mA alarm; 2 mA fo ,each activated device LED Wire type and connections ;Shielded or unshielded, twisted or ;untwisted wire, see note. •Terminal blocks for 18 AWG to 12 Connections ompatibility includes: IDNet communicating devices and TrueAlarm ensors including QuickConnect and QuickConnect2 sensors; see data heet 54090-0011 for additional reference. Note: Some applications may require shielded wiring. Review your system with your local Simplex product supplier. Page 3 54007-0001 Rev. 18 5/2021 4007ES Hybrid, Fire Detection and Control Unit with Addressable and/or Conventional Initiation Power supply output details RUI Communications controls up to 10 remote devices at up to 2500 ft (762 m) for single run, or 10,000 ft (3048 m) total if wiring is Class Band T- tapped; selectable as Class B or Class A Compatible RUI remote equipment includes: 4606-9202 and 4606-9205 Color Touchscreen Annunciators (up to 6 total), 4100 Series 24 1/0 and LED/ Switch modules, 4602 Series LED/Switch and 1/0 Annunciator modules, including 4602-9101 Status Command Units (SCU), and 4602-9102 Remote Command Units (RCU) IDNet 2 SLC output provides electrically isolated Class B or Class A communication; standard capacity is up to 100 addressable points with expansion for up to 250 points using up to two 4007-9803 IDNet 2 Loop Expansion Modules; as described in IDNet 2 addressable channel capacity 6!A output rating, including current for: special application notification appliances; IDNet devices; module currents; and auxiliary output current (battery charging, CPU, and power supply current does not subtract from the 6 A); when NACs are controlling Regulated 24 DC Appliances, total NAC current available is 3 A Four on -board Class B/Class A NACs, rated 3 A each for Special Application appliances; selectable for SmartSync horn and strobe control, or strobe synchronization; rated 2 A each for Regulated 24 DC appliances NAC EOL resistor values are selectable as: 10 kohms, 3.9 kohms, 4.7 kohms, 5.1 kohms, 5.6 kohms, or 15 kohms Battery charger is dual rate, temperature compensated, and charges up to 18 Ah sealed lead -acid batteries mounted in the battery compartment, and charges up to 33 Ah batteries mounted in an external cabinet Battery and Charger Monitoring includes battery charger status and low or depleted battery conditions; status information provided to the master controller includes analog values for: battery voltage, charger voltage and current, actual system voltage and current, and NAC current Low Battery Voltage Cutout is selectable when required (required for ULC Listing applications) 2 A Auxiliary Output (AUX/SNAC) can be selected either as resettable auxiliary power of 2 A @ 24 VDC, or selected to be a simple NAC (SNAC) for sounder base power, four -wire detector power, or door holder power Zone/relay module details Select as IDC or Relay; configure up to eight Class B IDCs, or up to four Class A IDCs; or up to eight Relay outputs rated 2 A resistive @ 30 VDC (N.O. or N.C.); or combinations of IDCs and Relays; each zone is separately configurable as an IDC or Relay output IDC Support. Each IDC supports up to 30, two -wire devices IDC EOL resistor values are selectable as: 3.3 kohms, 2 kohms, 2.2 kohms, 3.4 kohms, 3.9 kohms, 4.7 kohms, 5.1 kohms, 5.6 kohms, 6.34/6.8 kohms, and 3.6 kohms + 1.1 kohms; see instructions for more details Page 4 S4007-0001 Rev. 18 5/2021 ����~ N ��.�N���mex 4007ES Hybrid, Fire Detection and Control Unit with Addressable and/or Conventional Initiation Side View Reference Finished wall surface mu/nm semi -flush Trim Kit if used) Exposed box for semi -flush mounting 1-3w~(44mm)mmmvm Figure 5:4VO72Smounting and module location reference Table 2: Module locations A CPU and user interface assembly. B Location for optional 4007-9805 LED module, SIDACT location. �Note: The SDACT includes a 650-1838 flat mounting bracket (available separately). Some pre-existing systems with an angled SDACT bracket will need to be replaced with the flat mounting bracket when an NIC is installed. E Location for 4007-9801 Zone/Relay Module, 4007-9812 Dual RS-232 interface, 4007-9804 Dual Class A IbNAC Isolator (DCAI), or (as F Primary location for 4007-9861 Zone/Relay Module. G Location for additional 4007-9801 Zone/Relay Module, H Location for additional 4007-9801 Zone/Relay Module, 1 4007-9K7 or 4007-9808 City Circuit Module, or 4007-9809 Relay Module. 4007-9803 IDNet 2 Loop Expansion Modules, maximum of two (two are shown). K 4007-9803 IDNet 2 Loop Expansion Modules, maximum of two (two are shown). L Block L is an additional block that sits on spacers above block G and H. You can mount the 4007-9810 or 4007-9817 NIC in block L with or without modules mounted below it in blocks G and H. When you use fiber media cards and an SDACT is present, the SDACT requires a 650-1838 flat mounting bracket, ordered separately. M Battery location for up to 18 Ah batteries. Note: No conduit entry or wiring in this area, 14 7/8 in. (378 mm) wide. Note: A system ground must be provided for Earth Detection and transient protection devices, This connection shall be made to an approved, dedicated Earth connection per NFPA 70, Article 250, and NFPA 780. Page 5 I4007-0001 Rev. 185/2021 ����~ � m�.�0���mex 4007ES Hybrid, Fire Detection and Control Unit with Addressable and/or Conventional Initiation Table 3:*007s Hybrid product selection /ES Hylbricl witIn four conventional NACs, 6 A output power supply/battery charger 14b mA :190 mA 4007-9101 BA and one IDNet 2 SLC for up to 100 addressable points 4007-9102 Platinum Both models above include: One 4007-9W Zone/Relav Card 83 mA 295 mA Note: ^Models with (BNare available assembled inthe USA, The current draw for the 4007ES Hybrid Unit (without included modules) does not subtract from the bAofpower available for optional modules and external loads. For power supply loading calculations include all modules plus all external loads and exclude the 4007ES Hybrid Unit current, For battery standby calculations include all modules, all external loads, and the base 4007ES Hybrid Unit current, Module and accessories selection information Table 4: Factory programming options 4007-0831 Custom Labels and Programming (requires 400-8810) TahbeField installed optional modules Eight Point Zone/Relay MO ul�, 6k� p�5�7t� selectable as an IDC input or Relay output, Class A IDCs require two points (one out and one return)- one module is included as standard, select up to three 4007-9801 additional, Alarm current shown is for eight Class B IDCs using 33K EOL resistors with four IDCs in 83 mA max �,295 mA max alarm and four IDCs in standby, Supervisory current shown is for all eight IDCs in standby, Detector :current is added separately. Refer to 579-7103 ZonelRelay Module Installation Instructions for more with 1 module 25 VDC Regulator Module; 2 A maximum output, use to power Zone/Relay modules with 2 4007-9802 connected to initiating devices requiring nominal 25 VDC voltage. Refer to technical modules 290 mA 801 mA publication 579-832 2-Wire Detector Compatibility Chart for application details, with 3 modu les IDNet 2 Loop Expansion Module; provides an additional isolated loop with short circuit isolation to the l4007-9803 existing IDNet 2 channel, also provides an additional 75 addressable points to the IDNet 2 channel NA NA capacity, maximum of two Panel Mounted 48 LED Status Annunciator Module; provides 24 Yellow LEDs, 20 Red LEDs, no LEDs on four Red/Green for 24 10 mA 10 mA :4007-980S and LEDs that are programmable up to IDC zones of alarm and with LEDs trouble annunciation, or as required for custom annunciation requirements on SDACT Module for Point or Event Reporting Order 2080-9047 connection cables as required; see Table 9 :14007-9807 City Circuit Module with disconnect switch 20 mA 36 mA �4007-9808 City Circuit Module without disconnect switch 20 mA 36 mA i4007-9809 Relay Module, relays for Alarm, Supervisory, and Trouble; rated 2 A resistive @ 32 VDC 15 mA 37 mA 4007-9812 Dual RS-232 Interface Module; Compatible with Simplex remote printer, PC annunciator or third party 60 rnA 60 mA interface (two ports/connections maximum) Table 6: Field installed optional network modules Afar Page S4807-0001 Rev, 185/2021 Osimplex 4007ES Hybrid, Fire Detection and Control Unit with Addressable and/or Conventional Initiation Network interface and network media card product selection 4007ES FACUs are compatible with Simplex ES Net network or 4120 network fire alarm products. Refer to data sheet S4100-0076 for additional information on compatible ES Net fire alarm products. Refer to data sheet S4100-0056 for additional information on compatible 4120 network fire alarm products. Refer to data sheet S4100-0061 for additional information on the Building Network Interface Card (BNIC). Table 7: Batteries 1-9272 6.2 An 1-9274 10 Ah 12 V Batteries for cabinet mounting; select one battery model per system standby requirements; order quantity 1-9288 12.7 An of two; to be wired in series for 24 VDC 1-9275 18 An 1-9287 25 An Requires 4009-9801 external battery cabinet, see Table 8 1-9276 33 Ah Table 8: Battery cabinets Note: 33 Ah capacity requires 2081-9276 square 33 An batteries, 2080-9047 DACT cable, 14 ft (4.3 m) long, RJ45 plug one end, spade lugs on the other; order one per phone line connection 2975-9812 Red semi -flush box trim; 1 7/16 in, (37 mm) wide, , four corners and trim piecesfartop, bottom, and sides 2975-9813 Platinum semi -flush box trim; 1 7/16 in, (37 mm) wide, four corners and trim pieces for top, bottom, and sides 2081-9031 Platinum semi -flush box trim;� 1 7/16 in. (37 mm) wide, four corners and trim pieces for top, bottom, and sides 4081-9002 3.3 kohms, 1 W EOL resistor for Class B non -addressable initiating zones 4081-9018 10 kohms, I W EOL resistor harness for non -addressable NACs ZMZMMZMMM�� 120 VAC input I - Input power 246 VAC " input Power supply output 4007ES Hybrid power supply rating output ratings NAC ratings Auxiliary power tap Special application non -addressable appliances Regulated 24 DC non -addressable appliances Battery charger ratings Battery capacity range (sealed lead -acid Charger characteristics and batteries) performance Table 10: General specifications 2 A maximum @ 102 VAC to 132 VAC, !)U/bU Hz I A maximum -9 204 VAC to 264 VAC, 56/60 Hz Including module currents and auxiliary power outputs; 6 A total Output switches to 3 A each for Special Application Appliances battery backup during AC or 2 A each for Regulated 24 DC Appliances mains brownoufailure t conditions 2 A maximum, 24 VDC nominal (19.5 VDC to 31.1 VDC) Simplex horns, strobes, and combination horn/strobes and speaker/strobes; contact your Simplex product representative for compatible appliances Power for other UL listed appliances; use associated external synchronization modules where required UL and ULC listed for battery charging of 6.2 An up to 33 Ah; batteries larger than 18 An require a remote battery cabinet Temperature compensated, dual rate, recharges depleted batteries within 48 hours per UL Standard 864; to 70% capacity in 12 hours per ULC Standard S527 Table 11: Custom background and environmental details Item Destription, -- ----- ----- Supported file types: JPG, BMF, GIF, and PNG Custom background display details Recommended image type is JPG, recommended image size is 480 x 240, and the file size limit is 100 kb Environmental Operating temperature 32°F to 120°F (0°C to 49°C) Operating humidity Up to 93% RH, non -condensing @ 90°F (32°C) maximum Page 7 S4007-0001 Rev, 18 5/2021 4007ES Hybrid, Fire Detection and Control Unit with Addressable and/or Conventional Initiation AdditionalAdditional 4007ES and network product reference data sheets Table 12: t0 Serial DACT (SDACT) for 4100ES, 4010ES, 4007ES S2080-000� Connected Services Gateway - Central Station Communication and Safel-INC Cloud Services S2080-0091 Seismic Battery Brackets Reference 4003EC Voice Control Unit 4007ES Panels with Addressable Notification 4007ES Extinguishing Release Applications 4009 IDNet NAC Extender 4009 IDNAC Repeater External 110 Ah Battery Charger for 4100ES, 4010ES Graphic 1/0 Modules for 4100ES, 4010ES, 4007ES Interface to VESDA Air Aspiration Detection Systems NDU with SPS Power Supplies for 4120 Network InfoAlarm Command Center with SPS Power Supplies Multiple Signal Fiber Optic Modems for 4120 Networks BACpac Ethernet Module 4120 Network Products and Specifications Building Network Interface Card (BNIC) ES Net Network Products and Specifications NDU with SPS Power Supplies for ES Net InfoAlarm Command Center with EPS Power Supplies NDU with EPS Power Supplies for 4120 Network NDU with EPS Power Supplies for ES Net PC Annunciator TrueSite Workstation TrueSite Incident Commander 24-Pin Dot Matrix Fire Alarm System Remote Printer SCU/RCU Annunciators 4606 Series Color Touchscreen LCD Annunciators filTlY��.`l:lT1'+rT__�r•FT[:If�C1f:1�-�i Figure 6: 4007ES Hybrid with optional 48 LED Annunciator Module (4007-9805) S4003-0002 S4007-0002 S4007-0003 Figure 7: 4606-9205 (Platinum) Color LCD Touchscreen Remote Annunciator Figure 8: 4606-9202 (Red) Color LCD Touchscreen Remote Annunciator O 2021 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision,- and are subject to change without notice. Additional listings may be applicable, contact your local Simplex@ product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. Simplex, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited_ NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). S4007-0001 Rev.18 5/2021 93'smimplex UL, ULC, CSFM Listed; 4606 Series Color Touchscreen LCD Annunciators FM, NYC Fire Dept Approved* for 4007ES Fire Alarm Control Panels Remote Color Touchscreen LCD annunciators for use with Simplex® model 4007ES fire alarm control panels 4.3" (109 mm) diagonal color touchscreen display: • Provides the display features of the 4007ES fire alarm control panel at a remote location • Convenient and intuitive user interface provides detailed system status and individual point information • LED status indicators include Alarm, Priority 2, Supervisory, Trouble, Alarm Silenced, and Status of AC Power at the control panel • Supports dual language selection, including unicode character languages • Keyswitcb is used to enable default access level; additional user access levels are passcode protected; keyswitch and user access levels are configurable • Tone -alert sounder provides local audible indication • Three programmable control switches with status LEDs and provisions for custom labeling Additional features: • Available with platinum or red trim • Information is transmitted over a single unshielded twisted pair; separate wiring is required for 24 VDC power • Mounts flush on RAC( 944, 5-gang electrical box (supplied separately) • Up to 6 Color Touchscreen LCD Annunciators per 4007ES fire alarm control panel Mounting box options (ordered separately, see page 2 for more details): • Surface mount boxes in red or platinum • Semi -flush mount boxes in red or platinum, may be used for legacy annunciator retrofit applications 6 0 Local Annunciation and Control. 4606-9200 Series LCD Annunciators allows 4007ES fire alarm control panels to provide information and control switches at convenient locations away from the control panel. The color touchscreen LCD with backlighting displays information in clear and descriptive language. (English is standard, other languages can be programmed.) Typical content includes: point status (alarm, trouble, etc.), alarni type (smoke detector, manual station, etc.), number of system alarms, supervisory conditions, troubles, and custom location labels up to 40 characters long. Communications. Data communications require a single unshielded twisted pair that supports other annunciators on the same communications channel. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:0382 for allowable values and/or conditions concerning material presented in this document. NYC Fire Dept COA #6191A. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products, ' RICO* "I I UQjI i i11211111111111111 4606-9202 LCD Annunciator with Red Trim �escription Contihoed) Indications. Alarm, Priority 2, Supervisory, Trouble, and Alarm Silenced conditions are indicated by dedicated LEDs and a tone -alert audible indication. Each condition will cause the display to present a dedicated acknowledge push-button switch that silences the tone -alert but leaves the LED on until all conditions in that category are restored to normal. Custom Background. The 4007ES control panel supports a custom background image that is also displayed on each of the color touchscreen annunciators when status is normal. File types supported are JPG, BMP, GIF, and PNG. Recommended image type is JPG, recommended image size is 480 x 240, and the file size limit is 100 kb. Cinpratir. Keyswitch Access. Touchscreen display access can be controlled by a keyswitch with a key that is removable only in the disabled position. Access is configurable per annunciator. Enabled Operations. When the keyswitch is on, system status indications will be displayed as they occur with individual point detail as programmed at the control panel, and soft keys will be displayed to allow user actions. Screen Backlight. When the display has not been touched, and no new system status has occurred for 60 seconds, the backlight dims to 20% of normal brightness. If there is no activity in the system (System is Normal), the standby screen displays current time and date to verify proper operation. If an event occurs, or with the keyswitch activated, and the screen is touched, the backlight returns to full intensity Lamp Test. The display menu provides a lamp test feature that when selected, activates the 9 panel LEDs for 5 seconds. Dual -color LEDs will blink alternately. &I - �6- 1 i I 1AWME1 all, I to, III I � 3, 1 VNI WE I R. I I Air, _jllllglIAIPIII7 1�� Surface mount metal box for above annunciators 15"LOWE I• Annunciator: 13" W x 5.21 " H x 2" D (330 mm x 132 mm x 51 mm) RAC O 944 Box (reference): 12 W W x 4 Y2" H x 2 Y2" D (311 mm x 114 mm x 64 mm) 12 W Wx 4 Y2" H x 2 Y2" D (311 mm x 114 mm x 64 mm) Semi -flush mount metal box adapter for above annunciators; use — D for mounting on existing 2-gang, 4-gang, 6-gang, or 4" (102 mm) (311 mm x 114 mm x 44 mm) square flush mounted boxes Models with (13A) are available assembled in the USA by adding the suffix "BA". Suppression Products Note: Suppression is required where annunciator communications and power wiring exits and enters a building I&TVatold X01#11 power wiring when above 200 mA Operator information 111111110 MWIRM2 &W-1103affill Touchscreen Control Keys per LED; top two selectable as Red or Yellow, bottom selectable as Green or Yellow; for dual language, one of the control keys sample Main Menu showing can be programmed to toggle between languages (insert is blank, labels shown are for reference) WIMM AIF' vl Alarm Silenced yellow LED :dIcator AC Mains Power Status at LED Alarm Panel green LED 2 klllll . . . . . . . . . . . Tt key is removable only in disabled position p,cifi6ati6ns General Operating Specifications Voltage 18 to 32 VDC, system supplied Condition Current Details Alarm 124 mA Backlight at full intensity and tone -alert sounding Current Details Display Active 70 mA Backlight at full intensity, occurs when activity is in process Standby45 mA Backlight dimmed to 20% of full intensity, occurs after 1 minute of no system +,,,.+„ • + • t1i • f • ! • bROM a a ! • • •• • 'a. +!! • f Operator Screen Reference (shown approximately f011 size; refer to page 4 for additional screen reference) 3 S4606-0003-2 1/2017 Operator ScrOen f2eference I I R I $A 1AE to I a Lei I LOA I a A 4 First Floor Hallway HEAT DETECTOR DISABLE T 4, "R swo CIi5Ct71VR9ECT TRCttlHLE I'CIIIJT ASNORMALI MI-2 FULL STATID MICE AIDE RE 2-2 TYPE: ADAPU IDNET2 CARD UNIT NUMBER: 0 RUI N"ER : LOCAL PRIMARY STATUS j FIRE ALAR CURRENT DEVICE CORRECT DEVIL DEVICE ON-LIN PHYSICAL STATE ABNORMA System Alarm Screen identifies active alarms with custom labels displayed, arrows allow navigation through the list -,�Irfeu 1- f, I -xf-c«^L ime stamp and point details shown. WM35 12M:a*pm THU 19JUN,14 FIRE IDNET ZONE ENTRY34 12:WlOpm THU 191-JUN-14 P L '7 ULL STAWN 3 sW. �PULL S=VZONN .'JA.SWER operations as determined per panel. 4 S4606-0003-2 1/2017 MO -tinting Information or 2975-9462 (platinum), 2-1/2" deep 11, E UO ]LO r-A] Vag• Flush Mounting: Use 5-gang RACO 944 box or equal, 2-1/2" deep (supplied separately) # ffm2n. no. MO, M] I Wiring `Reference' I N Interconnection Wiring Notes: 1. Communications require 18 to 12 AWG unshielded twisted pair. 2. Power requires two, 18 to 12 AWG wires for 24 VDC system pow plus Earth Ground to each electrical box. 3. Refer to Installation Instructions 579-1172 for additional wiring R-707 M-1 �- � 4007ES Fire Alarm Control Panel 4606-9202 LCID Annunciators 5 S4606-0003-2 1/2017 TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorifed use is strictly prohibited. National Electrical Code and NFPA are registered trademarks o{the National Fire Protection Association (AIFPA). ®S i m p' ex Tyco Fire Protection Products • Westminster, MA ^ 01441-0001 • USA S4606-0003-2 1 /2017 www.simplex-fire.com t 2017 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as ofdocuntent revision date and are snhiect to change without notice. The fire alarm documents box (FDB) shall be constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "FIRE ALARM DOCUMENTS with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. Space Age Electronics, l6ca wwwlsae,corn 800.486.1723 Toll Free 508,485.0966 Local 508,485.4740 Fax — —, — -- 0, 1., ons and Approvals g ,dty Having Jurisdiction: m— Q A Infonnation 1-- .1- LT1p R11 I OWN test information, and alternate locations of additional records. Ordering Informatio Part # Description I Check out our Infinity line eFAD single gang 2 Gig digital storage solutions (IAMEFAD) This document is subject to change without notice, see doc # ED0479 for legal disclaimer ED0447 LT1 0505 R. ����0 � ��atasheet ���,��/����������� �= =������������ True4larrnADa�{}gSensing uLucccsrw���e�nw�npmvou~ ' TrueA|arrnAna|ogSensors— Photoelectric and Heat; Standard Bases and Accessories Features determined bycomparing the sensor's present value against its average value and time. TrweAlannanalog sensing provides: ' Digital transmission ofanalog sensor values using |DNetorMAPNET|| ^wo+w|nccommunicaVnns For use with the following Simplex products: '40O7ES,4010,4010pS,4100ES,and 410OUSeries control units 'and 40O8Series control units with reduced feature set (refer tndata sheet S4008-0001 fordetoUs) '402O'41OO'and 4120Series control units, Universal Transponders, and 21IOTrueAlarm[DTsequipped for MAPNETi|operation Fire alarm control unit provides: 'Peak value logging allowing accurate analysis n[each sensor for individual sensitivity selection 'Sensitivity monitoring satisfying NFPA72sensitivity testing requirements; automatic individual sensor calibration check verifies sensor integrity 'Automatic environmental compensation, multi -stage alarm operation, and display o[sensitivity directly inpercent per foot 'Ability todisplay and print detailed sensor information inplain English language Photoelectric smoke sensors provide: Sensitivity levels from O2%,o3]%. See Tmcgnrmsensors for more Heat sensors provide: - Three fixed temperature sensing thresholcls� 135'F, I 55'F and 190'F ' Rate*f-Asetemperature sensing 'Utility temperature sensing ' Listed tnUL5Z1 andUL[-S55O 'Operation isfor ceiling mwall mounting 'NGMA1rated. See TmeAannanalog sensing product selection chau for more information. Louvered smoke sensor design enhances smoke capture bydirecting flow mchamber; entrance areas are minimally visible when ceiling mounted 'Designed for EMI compatibility ' Magnetic test feature isprovided 'Different bases are available cnsupport asupervised "runsupervised output relay, and/or aremote LED alarm indicator Additional base reference: For isolator bases, refer mdata sheet S4098-0025 ' For sounder bases, refer todata sheet S40980028 'For photo/heat sensors, refer codata sheet S40980024(single address) and 54o98003J(dual address) Digital communication of analog sensing TrueAlannana|ug sensors provide ananalog measurement digitally communicated mthe host control panel using Simplex addressable communications. /uthe control unit, the data |sanalyzed and anaverage value isdetermined and stored, xnalarm orother abnormal condition is Intelligent data evaluation Monitoring each sensor'saverage value provides acontinuously shifting reference point. This software filtering process compensates for environmental factors, such asdust and dirt, and component aging, providing anaccurate reference for evaluating new activity, With this filtering, there isasignificant reduction inthe probability offalse or nuisance alarms caused byshifts insensitivity, either upnrdown. Control unit selection Peak activity for each sensor isstored massist inevaluating specific locations. The alarm set point for each TrueNannsensor isdetermined atthe host control unit, selectable asmore u/less sensitive asthe individual application requires. Figure 1:4098-9714Truexlann selection You can program sensor alarm set points for timed automatic sensitivity selection, such asmore sensitive acnight, less sensitive during day. Control unit programming can also provide multi -stage operation per sensor. Sensor alarm and trouble LED indication Each sensor base's LED pulses u»indicate communications with the unit. Ifthe control unit determines asensor isinalarm, orisdirty orhas some other type oftrouble, the details are annunciated atthe control unit and that sensor base's LED will heturned onsteadily. During psystem alarm, the control unit will control the LEDs such that an LED indicating trouble will return to pulsing to help identify the alarmed sensors, Base mounted address selection: Address remains with its programmed location Accessible from front, DIP switch under sensor Automatic identification provides default sensitivity when substituting sensortypes Integral red LED for power -on (po|s|ng),oralarm ortrouble (steady on) Locking anti -tamper design mounts unstandard outlet box Magnetically operated functional test °nbase products have been approved by r he Ca I ifornia State Fire Mars ha I (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFMListings o72-0026:zw 7271-002623''7270*o 6:2/6,xnx7300*026.217m,ullowamvvalue,avmo conditions concerning material presented mthis umurnemAdditional listings may beapplicable, contact your local Simplex 'Product supplier for the latest status, Listings and approvals under Simplex Time Recorder coare the property mn«nFire Protection Products. TrueAlarm Analog Sensors — Photoelectric and Heat; Standard Bases and Accessories Sensor bases 4098-9792, standard sensor base 4098-9789, sensor base with wired connections for: '2O98-980Oremote LED alarm indicator or4u98-9S2Zrelay (relay is unsupervised and requires separate 24VDg Supervised relay bases (not compatible with 21ZO[D0: '4V98'9791'4+w}mesensor base, use with remote orlocally mounted 2098'9737relay, requires separate 24VD[ '4Ug8-97gV'3+miresensor base, use with remote nrlocally mounted 409O-98bOrelay, nnseparate power required 'Supervised relay operation isprogrammable and can bemanually operated from control unit 'Includes wired connections for remote LED alarm indicator or 4098-9822relay (relay isunsupervised and requires separate 24VD[) Sensor base options `DP0contacts for resistive/suppressed loads, power limited rating of 3xm28VDC;non-power limited rating uf3Aat1Z0VAC (requires external 24vD[coil power) 4Q9$-9060,remote orlocal mount supervised relay: - SPIDT dry contacts, power limited rating of 2 A at 30 VDC, resistive; non - power limited rating of 0.5 A at 125 VAC, resistive 4098-9822, LED annunciation relay: ' Activates when base LED isonsteady, indicating local alarm ortrouble ' DPDTcontacts for resistive/suppressed loads, power limited rating nf 2Aot28YDC;non-power limited rating o[1DAac120VAC, (requires external 24 VDC coil power) 4098-9832,adapter plate: Required for surface msemi-flush mounting m4in. square electrical box and for surface mounting no4in. octagonal box ' Can heused for cosmetic retrofitting nnexisting 630in. diameter base product 20g8-9Woo'remote red LED alarm indicator: - Mounts on single gang box (shown in illustration) Figure 2: Remote red LED alarm indicator TmoNannsensor bases contain integral addressable electronics that constantly monitor the status nrthe detachable photoelectric orheat sensors. Each sensnr'soutput |sdigitized and transmitted tothe system fire alarm control unit every four seconds. Since TrueAlarm sensors use the same base, you can easily interchange different sensor types nnmeet specific location requirements. This feature also allows intentional sensor substitution during building construction. When conditions are temporarily dusty, instead n[covering the smoke sensors causing them tnbcdisabled, you can install the heat sensors without reprogramming the control unit, Although the control unit will indicate anincorrect sensor type, the heat sensor will operate at a default sensitivity providing heat detection for building protection at that location. Electrical Box Requirements: (boxes are by others) Without relay bzLhe box: 4" octagonal m4"square, 1-1/2" deep; single gang.2" deep With m��8aLhebox : 4^octagonal p,4^square, /'1ordeep, with 1-1/2" extension ring Surface mount ference-, minimum box depth Flush mount reference, mount even with final surface, or with up to 1/4" (6.4 mm) maximum recess Supervised Relay" Relay (mounts (mounts mbase electrical box or mbase electrical box) remotely) zzz, ; � �,�e, 2 Supervised Relayl(mounts in base electrical box or remotely; 2-3/8" X 1-1/4" x1 Relay NOT Review total wire count, wire size, and accessories being wired to determine required box volume, Adapter Plate, n� �ired for 1/4" mounting to surface mounted boxes Sq 4-7/8^(124mm)----�| (2wmm) TrueAlarm Bases Figure 3: Mounting reference Table 1: Product mounting - SKU reference �olate4098-9832 � 4098-9792 Page 2 S4098-0019 Rev, 257D021 TrueAlarm Analog Sensors - Photoelectric and Heat; Standard Bases and Accessories Features Sealed against rear air flow entry Interchangeable mounting EMI/RFI shielded electronics Heat sensors: Selectable rate compensated, fixed temperature sensing with or without rate -of -rise operation Rated spacing distance between sensors: 135°F (57.2°C) 60 ft x 60 ft 20 ft x 20 ft (6.1 m) for fixed 190°F (88°C)* (18.3 m) temperature only; RTI = Quick 40ftx40ft 50 ft x 50 ft (15.2 m) for fixed 155°F (68°C) (12.2 m) ;temperature with either rate -of -rise :selection; RTI = Ultra Fast Note: *1901F (88°C) ratings apply only to the 4098-9734 sensor. Smoke sensors: Photoelectric technology sensing 360° smoke entry for optimum response Built-in insect screens TrueAlarm photoelectric sensors use a stable, pulsed LED light source and a silicon photodiode receiver to deliver consistent and accurate low power smoke sensing. Three user selectable sensitivities for special applications are available for each individual sensor, 0.2%, 0.5%, and 1 % per foot. Standard sensitivity is 1.25% to 3.1 % per foot. The fire alarm control unit runs an algorithm that can vary the sensitivity for normal applications between 1.25% and 3.1 % per foot. Note: Fixed sensitivity settings higher than 1.0% per foot are not UL268 7th Edition compliant. The sensor head design provides 360° smoke entry for optimum response to smoke from any direction. Due to its photoelectric operation, air velocity is not normally a factor, except for impact on area smoke flow. (54 mn Figure 4: 4098-9714 photoelectric sensor with base "'► 6Mj • FA M TrueAlarm heat sensors are self -restoring and provide rate compensated, fixed temperature sensing, selectable with or without rate -of -rise temperature sensing. Due to its small thermal mass, the sensor accurately and quickly measures the local temperature for analysis at the fire alarm control unit. Rate -of -rise temperature detection is selectable at the control unit for either 15°F (8.3°C) or 20°F (11.1 °C) per minute. Fixed temperature sensing is independent of rate -of -rise sensing and programmable to operate at 135°F (57.2°C) or 155°F (68°C). The 4098-9734 sensor provides an additional 190°F (88°C) set point. in a slow developing fire, the temperature may not increase rapidly enough to operate the rate -of -rise feature. However, an alarm will be initiated when the temperature reaches its rated fixed temperature setting. TrueAlarm heat sensors can be programmed as a utility device to monitor for temperature extremes in the range from 32°F to 155°F (0°C to 68°C). This feature can provide freeze warnings or alert to HVAC system problems. Refer to specific panels for availability. _-7/8" (124 6 T LEE LEI 2-3/8" (60 mm)19 Figure 5: 4098-9733 heat sensor with base Figure 6: 4098-9734 high temperature heat sensor with base WARNING: In most fires, hazardous levels of smoke and toxic gas can build up before a heat detection device would initiate an alarm. In cases where Life Safety is a factor, the use of smoke detection is highly recommended. Sensor locations should be determined only after careful consideration of the physical layout and contents of the area to be protected. Refer to NFPA 72, the National Fire Alarm and Signaling Code. On smooth ceilings, smoke sensor spacing of 30 ft (9.1 m) may be used as a guide. For detailed application information including sensitivity selection, refer to Installation Instructions 574-709. Page 3 54098-0019 Rev.26 7/2021 ssimplex TrueAlarm Analog Sensors - Photoelectric and Heat; Standard Bases and Accessories MEWsensing product selection chart 0 , Table 2: TrueAlarrn sensor bases (for use with sensors 4098-9714 and 4098-9731 White 4 in. octagonal or 4 in. square Standard sensor base No options box, 1 1/2 in, min. depth; or single; ,4098-9776 Black gang box, 2 in, min. depth 4098-9789 White 4 in. octagonal or 4 in, square box 40989789 Sensor base with connections 2098-9808 remote alarm indicator or Note: 4098-9789IND White for remote LED alarm indicator 4098-9822 unsupervised relay i4098-9789IND or unsupervised relay Box depth requirements depend 4098-9775 Black on total wire count and wire size, 4-wire sgnwr Supervised relay 2098-9737 supervised remote relay refer to accessories list below for I White base with connections for LED 2098-9808 remote alarm indicator or reference. indicator or unsupervised relay 4098-9822 unsupervised relay ** 4098-9791 and 4098-9780 are 2 wire sensor supervised relay 4098-9860 supervised remote relay _ coin atible with the 2120 p NO 4098-9780** White base with connections for LED 2098-9808 remote alarm indicator or CDTT Indicator or unsupervised relay 4098-9822 unsupervised relay Note: * SKU numbers ending in IND are assembled in India. Refer to Application M ual 574-709 and Installation Instructions 574-707 for additional information. Table 3: TrueAlarrn sensors SKIU,, 1, C 1, or rJotibin', ou qu'i 4098-9714 9t±ttihite 1:4098-9714 IND Photoelectric smoke sensor 4098-9774 Black Bases 4098-9775, 4098-9776, 4098-9792 to base requirements •Refer :4098-9733 White 4098-9789, 4098-9791, and 4098-9780 4098-9778 Heat sensor Black 4098-9734 White High temperature heat sensor NEMA 1 rated. Table 4: TrueAlarrn sensor/base accessories ISM_ 7_150*rll otilifit fttequlromen s, 2098-9737 Supervised relay, Mounts remote or in base For use with 4098-9791 base Remote mounting requires 4 in. electrical box octagonal or 4 in. square box, 1 1/2 in. minimum depth 4098-9860 Supervised relay, mounts remote or in base'Foruse with 4098-9780 base Base mounting requires 4 in. octagonal electrical box box, 2 1/8 in, deep with 1 112 in. extension ring li2O98-9808 Remote red LED alarm indicator on single Bases 4098-9789, 4098-9791, and Single gang box, 1 1/2 in, minimum depth gang stainless steel plate 4098-9780 Unsupervised relay, tracks base led status. Bases 4098-9789, 4098-9791, and 4 in. octagonal box, 2 1/8 in. deep with I 4098-9822 Note: Mounts only in base electrical box, 4098-9780 112 in, extension ring Bases 4098-9792, 4098-9789, Required for surface or semi -flush 4098-9832 Adapter plate mounted 4 in. square box and for surface 4098-9791, and 4098-9780 mounted 4 in. octagonal box 1 NEMA 1 rated 9-3928�� Table 5: General operating specifications ommunications and sensor supervisory power IDNet or MAPNE 1 11 communications, auto -selected, I address for each ommunications connections Screw terminals for in/out wiring, 18 to 14 AWG (0.82 MM2 to 2.08 mm 2 emote LED alarm indicator current 1 mA typical, no impact to alarm current emote LED alarm indicator and relay connections Color coded wire leads, 18 AWG (0.82 mm2) L listed operating temperature range 32°F to I 00'F (0°C to 38°C) Page 4 S4098-0019 Rev. 26 7/2021 M-1 imp M- TrueAlarm Analog Sensors - Photoelectric and Heat; Standard Bases and Accessories Table 5: General operating specifications Table 6: 4098-9791 Base with supervised remote relay 2098-9737 Table 7: 4098-9780 Base with supervised remote relay 4098-9860 communications Table 8: 4098-9822 Unsupervised relay, requirements for bases 4098-9789,4098-9791, and 4098-9780 Page 5 S4098-0019 Rev. 26 7/2021 Osimplex TrueAlarm Analog Sensors - Photoelectric and Heat; Standard Bases and Accessories © 2021 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision and are subject to change without notice. Additional listings may be applicable, contact your local Simplex@ product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. Simplex, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). S4098-0019 Rev. 26 7/2021 iL,0C, CSFM Listed; FM Approved * IDNet or MAPNET 11 Communicating Devices Addressable Manual Stations Individually addressable manual fire alarm stations with: 'Power and data supplied by|DNesorMAPNET||addressable communications using asingle wire pair 'Operation that complies with ADArequirements 'Visible LED indicator that flashes during communications and ison steady when the station has been activated ' The NO GRIP Single Action Station and Retrofit Kit are available with amore easily operated pull lever for applications where anticipated users may find the standard station lever difficult toactivate ^ Pull lever that protrudes when alarmed Break -rod supplied (use isoptional) ^Models are available with single mdouble action (breakglassmpush) operation ' ULlisted toStandard 38 'NEMA1rated. See Addressable manual station produuselection for more information, Compatible with the following Simplex control panels: ^Model Series 4007ES,40084010,401OES41O0ES,4100U4020, 410land 412Ofire alarm control panels equipped with either |DNetor MAPNETUcommunications ' Model Series 2120Communicating Device Transponders ([03) equipped with MAPNETUcommunications Compact construction: 'Electronics module enclosure minimizes dust infiltration 'Allows mounting |nstandard electrical boxes ' Screw terminals for wiring connections Tamper resistant reset key lock, keyed same as Simplex fire alarm cabinets. Multiple mounting options: 'Surface nrsemi-flush with standard boxes o/matching Simplex boxes ' Flush mount adapter kit ' Adapters are available for retrofitting tocommonly available existing boxes Description The Simplex addressable manual station combines the familiar Simplex manual station housing with acompact communication module that |seasily installed nosatisfy demanding applications. Its integral individual addressable module (AM) constantly monitors status and communicates changes tothe connected control panel through |DNetor MAPNETUcommunications wiring. Activation ofthe 4Og9-9UO4single action manual station requires a firm downward pull ooactivate the alarm switch. Completing the action breaks uninternal plastic break -rod which isvisible below the pull lever, use isoptional. The use ofabreak-rod can headeterrent tovandalism without interfering with the minimum pull requirements needed for easy activation. The pull lever latches into the alarm position and remains extended out ofthe housing toprovide avisible indication. Single Action NO GRIP Station 4099-9021.For applications such as California Building Code, Title I4,which requires "Controls and operating mechanisms shall heoperable with one hand and shall not require tight grasping, pinching ortwisting rf the wrist" the model 4099-9021 station provides emore easily operated pull lever compared toasndard stations. Retrofit ufexisting stations /savailable using the 4099'98O5 Retrofit kit, Double Action Stations (Breakglams) require the operator mstrike the front mounted hammer nnbreak the glass and expose the recessed pull lever. The pull lever then operates asasingle action station. 4099-9004 4099-9021NO 4099-9805N0 Single action GRIP Single action GRIP Retrofit kit 4099'9005Breakgles 4099-WkhZ099-98289OO6P�oh Institutional Cover kit Double Action Stations (Push Type) require that aspring loaded interference plate, marked PUSH, bepushed back coaccess the pull lever ofthe single action station. Station reset requires the use ofakey noreset the manual station lever and deactivate the alarm switch. |[ you use the break-md.you must replace it. Station testing |s performedby physicalactivation o[the pull lever. You can also perform electrical testing byunlocking the station housing to activate the alarm switch. �,Anaa_nnn"u­^mnm, Osimplex IDNet or MAPNET 11 Communicating Devices Addressable Manual Stations Specifications Refer to 4099 MAPNET IV IDNetAddressable Manual Pull Station with LED Installation Instructions 579-1135 for additional information. Table 1: Specifications Addressable manual station semi -flush mounting Square Box Mount 4 in. (102 mm) square box, 2 1/8 in. (54 mm) minimum depth, RACO #231 or equal (supplied by others) 0 M = oi= 0 I ! ' 4 . 1• 0 - 0 NO•W - WW • 4 in. square box with :over plate ------------ Single gang box outline I I Wall surface' *s-impleill Semi -Flush Mount Side View Figure 1: Addressable manual station semi. -flush mounting Page 2 S4099-0005 Rev. 4 02/2021 Osimplex IDNet or MAPNET 11 Communicating Devices Addressable Manual Stations Addressable manual stations surface mounting Preferred mounting. For surface mounting of these addressable manual stations, the preferred electrical boxes are shown in Figure 2. Additional mounting reference, See Addressable manual station, additional mounting information for Wiremold box mounting compatibility. Figure 2 shows the 2975-9178 box and the 2975-9022 cast box. 2976-9178 Box 5-3/16 in. H X 4 in. W x 2-3/16 in. (132 mm x 102 mm x 56 mm) (ordered separately) \ � { 4/ III , , � 5 in. (127 mm) 2975-9022 Cast Box �127 mry x 8 mNm x456 (ordered separately) W N Access for 3/4 in. threaded conduit located top and bottom 4- f3slimplek 1 in. (25.4 mm) 3-3/4 in. (95 MM). 4099 Series Addressable Manual Station mamzm= Page 3 S4099-0005 Rev, 4 0212021 IDNet or MAIDNET 11 Comi-nunicating Devices Addressable Manual Stations Surface mount side view with internal detail Figure 3shows the l975'917Obox, 1-1/4 in. (32 mm) Simplex 2975- 178 box Field wiring (shown for reference) (shown for reference)\,, Address setting under with cover open) Station cover hinges open for Figure 3: Surface mount side view with internal detail Application reference Refer to NFPA 72, the National Fire Alarm and Signaling Code, and all applicable local codes for complete requirements for manual stations. The following summarizes the basic requirements: 1 Stations shall be located in the normal path of exit and distributed in the protected area such that they are unobstructed and readily accessible. 2. Mounting shall bewith the operable part not less than 42in. <1.07m>and not more than 4Din, (122m) above floor level. 3. Acleast one station shall beprovided uneach floor. Additional stations shall be provided to obtain a travel distance not more than 200 ft (61 m) tothe nearest station from any point inthe building. 4, When manual station coverage appears limited in any way, additional stations should be installed. Page S4099-0005Rev 402O021 ����~ 0 m�.�����mex |DNetorMAPNETUCommunicating Devices Addressable Manual Stations Addressable manual station, additional mounting information For retrofit and new installations, additional compatible mounting boxes and the required adapter plates are shown in Figure 4. Figure 4 shows the 2O99-9814surface trim for VVipemo|dboxes and the 2099'9813semi-flush trim for Zgang switch boxes. Wiremold receptacle box model V5744-2 (supplied by Addressable I 'Irol WWWOWA station I MA WN I Figure 4:Addressable manual station, additional mounting information Addressable manual station, flush mounting information Flush mount adapter kit 209e919,mack / um90—omm.Beige , Box must berecessed into wall 1 in. m,'1min. (25.4mmm2emm M11 wall 4-owino21 mm____~ surfacers 6-3wim'171rm ~ - Front View Side View Figure 5: Addressable manual station, flush mounting information The flush mount adapter kit isavailable inbeige <2099'982O>orblack (2099'9819). Page S4099-0005Rev 40212021 Ssimplex IDNet or MAPNET II Communicating Devices Addressable Manual Stations Addressable manual station product selection Table 2: Addressable manual station product selection red housing with white letters and white pull lever �w eat, Writ 4099-9004, see note Single Action, English FIREALARM PULL DOWN UL, ULC, FM, CSFM SinglehULCAction, Bilingual English and 14099-9004CB, see note FEU FIRE TIREZ PULL Fren4099-9004CF, see note Single Action, French ALARME FEU ABAISSEZ 4099-9004Po, see note Single Action, Portuguese FOGO ALARME PUXE UL, FM 14099-9004SP, see note Single Action, Spanish ALARMA FUEGO DALE :4099-9005, see note DoubleAction,Breakglass FIRE ALARM PULL DOWN UL, ULC, FM, CSFM operation, English Double Action,-Breakglass 4099-9005PO, see note FOGO ALARME PUXE operation, Portuguese Double Action, Breakglass UL, FM 4099-9005SP, see note ALARMA FUEGO DALE o eration S anish 4099 9006, see note Double Action, Push operation, FIRE ALARM PUSH PULL DOWN UL, ULC, FM, CSFM English 4099 9006P0, see note Double Action, Push operation, POGO ALARME EMPURRE PUXE Portuguese Double Action, Push operation, - UL, FM 4099-9006SP, see note Spanish ALARMA FUEGO EMPUJE DALE - !4099-9021, see note Single Action NO GRIP operation, English FIRE ALARM PULL DOWN UL, ULC, FM, CSFM Note: NEMA 1 rated when used with 2975-9178 back box. Table 3: Accessories 2975-9022 Cast aluminum surface mount 2975-9178 :Surface mount steel box, red gang switc 2099-9819 Flush mount adapter kit, black 2099-9820 Flush mount adapter kit, beige Retrofit Kit for field conversion of a 4099-9805 Instructions 579-1007 for details 2099-9803 :Replacement breakglass 2099-9804 Replacement break -rod Institutional cover kit for field instal 2099-9828 Note: Covers LED indicator 2099-9814 Surface trim plate for Wiremold bo 2099-9822 Replacement retaining clip for brec 252-019 :B kev for manual station reset. action station to a NO GRIP station, refer to the NO GRIP Actuotor M x V5744-2. red © 2021 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision and are subject to change without notice. Additional listings may be applicable, contact your local Simpler product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. Simplex, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm Code are registered trademarks ofthe National Fire Protection Association (NFPA). 54099-0005 Rev.4 0212021 LMMUMMMMi�-307-mi M UL, ULC, CSFM Listed, FM Approved, IDNet and MAPNET 11 Communicating Devices, MEA (NYC) Acceptance* Individual Addressable Modules (IAMs) a WI M IDNet or MAPNET 11 addressable communications supply both data and power over a single wire pair to provide": • Supervised Class B monitoring of normally open, dry contacts • Total wiring distance from IAM to supervision resistor(s) of up to 500 ft (152 m) • Monitored connection is compatible with Simplext 2081-9044 Overvoltage Protectors for outdoor wiring or electrically noisy applications • For use in indoor locations up to 1580 F (70' Q such as attic spaces or similar applications For use with following Simplex control panels: • Model Series 4007ES, 4008, 4010, 40 1 OES, and 4 1 OOES fire alarm control panels for IDNet communications • Model Series 4100/4 1 OOU/4 I WES, 4120, 4020, and 2120 Communicating Device Transponders (CDTs) equipped with MAPNET 11 communications Model 4090-9001: • Enclosed design minimizes dust infiltration • Mounts in standard single gang electrical box • Screw terminals for wiring connections • Visible LED flashes to indicate communications • Optional covers are available to allow LED to be viewed after installation (requires mounting bracket, ordered separately) WXOTUUK�#� • Encapsulated design for extended exposure to high humidity (LED is not present on this model) • Color coded 18 AWG leads for wiring IDNet communications provides current limited monitoring: • Provides monitoring of tamper switch (supervisory) and waterflow switch (alarm) on same circuit using one point • Available with IDNet communications only Multiple operation modes are available and are selectable at the control panel: • Contact closure status can be tracked • Momentary contact closure conditions can be selected at the panel to be latched or tracked (not available with the 2120 CDT) These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:223 for allowable values and/or conditions concerning material presented in this document. Accepted for use — City of New York Department of Buildings — MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products . SbP1R111D'jA'm' 0 V IMR, 514-E31 DATE CODE: � 59!94 I §:d:oh:r, O ]p 191 ge= 111 'W a•lmi air, im m Lem I I a g 1 ua VIM ag FAUJ ISSUF NO, 4090-9051 Supervised [AM DA--,cribi tinin Individual addressable modules (IAMB) receive both power and communications from a two -wire MAPNET 11 or IDNet circuit. They provide location specific addressability to a single initiating device (such as single station smoke detector alarm contacts or heat detector contacts) or multiple devices at the same location by monitoring normally open dry contacts and the wiring to an end -of -line resistor. Model 4090-9001 is packaged in a thermoplastic housing and provides screw terminal connections and a status indicating LED. Model 4090-9051 is an encapsulated package with wire leads. It does not provide a status indicating LED. Lxd',Ona''Iratian Antilitathr Contact Closure. Closure of the monitored contact(s) initiates an alarm or other response as programmed at the fire alarm control panel. An open in the monitored circuit wiring will cause a trouble to be reported. Panel Selections. Selections can be made at the control panel to maintain the alarm condition if the initiating device contacts are momentary, such as from a rate -of -rise heat detector, or to track the device contact status (not available with the 2120 CDT). gill I I ARL01 I I tall I a p For use with IDNet communications only, these lAMs can provide quad -state sensing of normal, open circuit, short circuit, and current limited conditions. (Program type is "T-sense,") With the proper end -of -line and current limiting resistors, dual functions such as tamper switch and waterflow switch monitoring can be determined and communicated by a single addressable point. 1z Of WO 4.7kQ,1/2W Use for current limited monitoring applications 1.8 kQ, 1/2 W 'S" 6fications WE= Input Requirements Normally open, dry contacts 4090-9001 Screw terminals for in/out wiring, 18 to 14 AWG wire Wire Connections 1 2 MM2) 1 (0.82 mm to 2.08 4090-905'r-i i Color coded wire leads, 18 AWG (0.82 MM2) 8" long (203 mm) Installation I�nstrtion uc" uc 574-331 for 4090-9001; 579-572 for 4090-9051 Reference Documents r In Field Wirin:g Diagram 842-073 for IDNet operation; 841-804 for MAPNET If operation Wiring Distances 500 ft (152 m) maximum without protectors Distance from IAM to Contacts 400 ft (122 m) maximum with 2081-9044 Overvoltage Protectors Wiring Distance Reference per channel, MAPNET 11 o 2500 ft (762 m) maximum from fire alarm control panel IDNet Communications 10,000 ft (3048 m) maximum total wiring distance (including T-Taps) Mechanical 4090-90ON'l -9/16" W x 1-3/4" H x 1-1 /4" D (40 mm x 44 mm x 32 mm) Dimensions 4090 �O5 11-9/16" W x 1-9/16" H x 9/16" D (40 mm x 40 mm x 14 mm) H o u si n g M a ter i a I , 40 90-9001 _Ni r Black thermoplastic Encapsulation Material, 4090-9051 Epoxy, beige Temperature Range 32o to 158o F (Oo to 70o C); intended for indoor operation mm�� Up to 93% RH at 100' F (38' C) 2 S4090-0001-12 8/2016 Mounting informations M 4-1/4" (1 08 mm) vm,61111p W - Wk, �JA 131 'I I M"I'll Field wiring shown for reference I go MMMM box 2-1/2" (64mm) minimum depth (supplied by others) #A #I;W!,VArJ I I M I I VATJ OAT1,7&A MUM I M 011 rM RVA91121-7d I IR R WA RE a Lola rao I q I I IMO a L i I i I I W IMMM= MMEMM. 2-1/2" 1.0--(64 mm) 4090-9806, Trim plate for semi -flush mounted box NJ 2-13/16" 41 (72 mm) EM W#TtT#WJ*;V#vl 7IT7.70 bracket, ordered separately 11,11I•M11191111 RHINO,: I pi�jyyg'•i 1�1 � man= S4090-0001-12 8/2016 Uhting Information:, Address setting is at rear of housing 4090-9051 Encapsulated Supervised IAM box 2-1/2" (64mm) minimum •-• (supplied by • r*ingle gang blank cover • and US'I M ex Tyco Fire Protection Products • Westminster, MA - 01441-0001 • USA S4090-0001-12 8/2016 www, simplex -fire. com 2016 7ycoFrre Protection Products. All rights reserved. Allspectficalions and other information shown were current as of document revision date and are sidirect to change without notice. Strobe, Horn Strobe, and Horn Notification Appliances The VVhealockOExcedeCmSeries nfnotification appliances feature leek modern design that will please building with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes, voltage test points, 12/24 VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. The WheelockO ExcederTm Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit. All strobe models feature an industry first of 8 candela settings on a single appliance. Models with an audible feature 3 sound settings (90, 95, 99 dB). All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The VVheelockw Exoader:rw 8aheu of wall and ceiling notification appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting base can be pre -wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre -wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show mnopen until the appliance ioinstalled. The UK4Ballows for consistent installation and easy replacement ofappliances if required. Wall models provide anoptional locking screw for extra secure installation, while the ceiling models provide acaptivated screw to prevent the screw from falling during installation. UO Sleek Modern Aesthetics Finger Slide Switches Voltage Test Points Multiple Voltages 3Audible Settings 90\95,99u13 ~** Candela. Settings w8 �/-1sxsrsmonsean1unooxos Ceiling -1ammmmramm11nusonrr Mounting Boaa ~~~ 0Universa| Ceiling and Wall Mounts moeacxmvxTypes Environmentally Friendly Low Current Draw °Compared tocompetitive models Patented rn Strobe Ratings per UL 1971 & Anechoic at 24VDC tage RangeVDC Regulated Voltage Regulated Voltage RangeVDC Regulated Voltagie • ! ��®��� RangeVI Horn Ratings per UL Anechoic Regulated Voltage RangeVDC I Sync w/ Strobe DSM or Mounting Model Candela Wheelock Power 12124 VDC* Options Supplies HSR 15/1575/30/75/951110/135/185 X X UMB** HSW 15/1575/30/75/95/110/135/185 X X UMB** HSRC 15/30/60/75/95/115/150/177 X X UMB** HSWC 15/30/60/75/95/115/150/177 X X UMB** e o� STIR 15/1575/30/75/95/110/135/185 X X UMB** STW 15/1575/30/75/95/110/135/185 X X UMB** STRC 15/30/60/75/95/115/150/177 X X UMB** STWG 15/30/60/75/95/115/150/177 X X UMB** UMB** HNR X X HNW X X UMB** HNRG «� X X UMB** HNWG X X UMB** location at all times when installed. The ay.,04,16 shAl �iaye,2 -AiMmven*,f tXree (3) fiel� select,;�,.'#lle settii�gs ftr if.VA levels,2.i�,t s�?.Il �-?ve,? ch*ic--#,fc+6ti?,i�I 4r tem-,#,#Ir?l (Code 3) audible outputs. iwNl Ail flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock' synchronization protocol. KOMLOMA OPMEM1011MI EM ; RINIIIIAM111WOMPETAN ILMMOIXII 20- I Member Weatherproof appliances, Version 2 Designed for life safety, performance andm|iabi|hy, the Wheelock weaonerpomnotification appliances Weatherproof Appliances Strobes Horn strobes ASWP Horn AH'24VVPAH-12VVP K4u|rimnohorn strobes K8TVVP K4u|tinonohoms MT Speaker strobes ET70VVP Speakers EF1010'EF1080 All strobe models are ULdual listed —meeting both UL1638and UL1971 requirements. As dual listed appliances, these weatherproof strobes, horn strobes and speaker strobes are listed for outdoor applications under UL 1038eswell as under UL197l.the Standard for Safety Signaling Devices for Hearing Impaired. With enextended temperature range of-40°F to 150^F (-40'C no 80"C)^Wheelock weatherproof appliances meet or exceed UL outdoor test requirements for rain, humidity and corrosion resistance while providing multiple strobe intensity options, including the highest strobe ratings available for area coverage per NFR472 strobe spacing tables (up to 185 candela for wall mounting and 177 candela for ceiling mounting), FA,RTON Powering Business Worldwide To enable weatherproof mounting, Eaton provides the ind's widest choice ofmounting options for surface or unique semi -flush installation. Models are available for surface mounting no Wheelock weatherproof backboxesonwalls orceilings. The i |VVpK|ToUowptho weatherproof buokboxoo 0013,VVP13B orVVPSB8> tnbomounted toarecessed electrical box for concealed conduit installation. Forsnmif|uoh installation, theVVP4° andVVFRA° kits allow ecustomer mmount the weatherproof appliances toarecessed electrical box without the need for an external weatherproof backbox Soo Table 10 on page three of this document for o summarization ofthese mounting options and the required accessories. All models may hosynchronized using the Wheelock DSM sync modules, Wheelock suppliespower rother manufacturers panels incorporating the Wheelock patented sync proto- col. The horn output of horn strobes can be independently controlled on 2-wire circuits using the Wheelock patented sync protocol. ,m/vvrhorn strobe models are +w'reappliances; the strobes can hesynchronized while the audible can beconnected noacoded fire alarm system, MThorns may bosynchronized, using the temporal Code 3 horn setting, Technical Data TD450112E0 Janvarv2822 ~ Weatherproof temperature range of —401Fto 150pF(-10,Cto66'C)° ` Dual listed strobe models <UL 1038and VL 1871> ^ |ndustry'shighest strobe candela options ` Strobes and Code 3 horn synchronize using the Wheelock Sync Modules nrpanels with built-in Wheelock Patented Sync Protocol ^ Models with field selectable tone, dBA and candela settings ^ Wall orceiling mounting options ~ MTVVPand ET7UVVPkits that include the device and |OB beokbox are available; See ordering information for specific models ` Surface orsomi-flush mounting (indoor and outdoor) ° IN/OUT wiring termination accepting two #l2-lBAVV8wires at each terminal Note: Please read these specifications and associated installation instructions, before using, specifying, or installing this product. Visit Eaton.com/massnotification for current installation instructions. Approvals include: ULStandardb 1971' 1038 464ond 1480 UUC, California State Fire Marshal (C3FK4); and Factory Mutual (RN) (see agency approvals by model number on pages 4and 5 of this document) ~ The series R3SVVpASVVPAH-24VVR K4TVVp2475VV and K8T-l2/24have UL/ULCapproval down to-4O°p.The ET-lO1O and ET70VVP have ULapprova| down to-40^F ^ Compliance with the following requirements: NFR4; UFC; FCC' ANSI 117.1; OSHA Part 29, 1910.165; AD Strobes are designed to flash I flash per second minimum over their UL Listed Regulated Voltage Range. All candela ratings represent minimum effective Strobe intensity based on ULStendards 1971 and l038asindicated incandela ratings table. Mndn|o are available in red or white, Contact Customer Service for order code and delivery. Figure 1. RSSWP front and side views Figure 2. ASWP front and side views 5,120 C= i Figure 4. ET70WP front and side views Figure 5. MIT front and side views 2 smnmw°w,eatv.wm Wheelock AH, AS, MT, RSS, ET Technical Data TD450112EN January 2022 4.29 4.09 0 0 4.29 t92 Figure 6. ET-1010 front and side views Table 1. Maximum RMS current for AH models Table 2. dBA ratings for ET-1010 and ET70WP models UL Max Current for AH UL Reverberant dBA @ 10 ft. 24 VDC Watts High (99) dBA 0.080 Model 1/8 1/4 1/2 1 2 4 8 Med (95) dBA 0.043 ET-101 0 77 80 83 86 7 92 94 Low (90) dBA 0.021 ET70WP 77 so 83 86 88 91 93 Table 3. Maximum RMS current and dBA, MT weatherproof models MTWP/MT MT UL Reverberant d6A at 10 Feet 24VOC 12VDC dBA HI STD HI STD 24VDC "1 STD 12VDC HI STD Horn0,108 0.044 0.177 0.034 92 87 92 87 Bell 0.053 0.024 0.095 0.020 86 80 86 80 March Time 0,104 0.087 0.142 UP 89 84 89 84 Code 3 Horn 0.122 0.035 0.200 0.034 88 83 88 83 Code 3 Tone 0,135 0.035 0.152 0,021 85 80 85 80 Slow Whoop 0.098 0.037 0,142 0,035 Siren 0.104 0.036 0.152 0.030 90 85 90 85 Hi/Lo 0.057 0.025 0114 0.026 89 84 89 84 86 81 86 81 Table 4. Strobe and ASWP ratings Candela ratings Maximum RMS Current for ASWP Max RMS Current - Strobe Candela UL 1971 UL 1638 @ 77°F UL 1638 @ -40°F (strobe only) High Mod Low 2475W 30 (D 180 115 0.138 0.168 0.155 0150 2475C 15 180 115 0.138 0.168 0,155 0,150 135 135 56 0300 0.355 0.340 0,335 MCWH 185 185 77 0.420 0.480 0.465 0.460 115 115 47 0.300 0.355 0340 0335 MCCH 177 177 73 0.420 0.480 0.465 0.460 24185 185 185 77 0A20 24177 177 177 73 0.420 (D Wall mount rating only EATON www.eaton.com 3 Technical Data TD45O112EN Wheelock AH,AS, MT, RSS,ET ° Jmnvarvao2o Wall mount models Table 5. Specification and ordering information Agency Approvals Model Number Finish Kit Order Code UL ULC CSFM FM Strobe Audible strobe V ASWP-2475W-NR ASWP-21MCWH'0 ASWP-24M0VH'R* Red nou Rod White 902 0200 5137 51*0 X X X x X X X X X X X X X X — _ M"ukmno,trnh= MTWP-245W-FR Red 8420 X X X X MnNP-245W-Rm White 3112 X X X X MnNP-24MCVYH'FR Red 5132 X X X — MTWP-24MCVVH'RN White 5134 X X X — MRNP-2475W-FRK|T MmVP'2*75W-RwK|T Red White Includes |OB'Rhackbnx Includes |0B4Nbankbnx 9882 8883 X X X X X X X X MRWP'2475W-NVVKIT White Includes 0B4Nhockbnx 9084 X X X X Speaker strobe EV0NP'2475m'FR Red 8077 X — X X ET70NP'2475W-Rm White 3179 X — X X B70WP'2475W-ALR Red 4480 X — X X ET70mP-2475W-A&m White 4481 X — X X ET70WP'24185VuFR Red 4885 X — X X [T70mPz4185W-Rm VVmm /891 X — X x ET70mP'2475W-F8K|T Red Includes |UB'Rbockhnx 9078 X — X X ER0NP'2475W-RNK|T White Includes 08'YVhaokhnx 8079 X — X X ET70mP'24135W-NVV -- White 1111 X — X X 870wp'24135m/pn Red 4872 x — x x ET70NP-24135W-Rm White 405 X — X X B70NP-24135W-A&w White 6407 X — X X Ceiling mount models Table 6. Specification and ordering informatil Agency Approvals Model Number Finish Kit Order Code UL ULC CSFM FM Strobe RS0NP-2475GF8 Red 4338 X X X X R3SWP-2^3C-RN CodeHod White 444 X X X X RSSVVP'24MCCH'FR 5187 X X X — RSSVVP'21MCCH'Rm White 5107 X X X — Audible strobe ASWP�4�CfR Red 4251 X X X X A3WP-2*75C'RW N&im 4502 X K X X ASWP-24MCCH'FR Red 51/0 X X X — ASWP-24MCCH-FN White 5167 X X X — Multitone strobe MTWP-2475C-FR Red 4457 X X X X �NxP2475C'Rm White *08 X X X X MnWP-24MCCH'FR Red 5102 X X X — MTWP-24MCCH'Rm White 5122 X X X — Speaker strobe B70NP'2475C'FR Rod 4*52 X — X X B70NP'2475C'Rm White 4454 X — X X B70NP'24177C'FR Red *845 X — X X En0WP'24177C'Rm White4838 X — X X ED0NP'2475CfHKU 17 Rod Includes 08'Rha:kbux 9080 X — X X ET70NP'2475C'RmK|T White Includes |OB\whaokbox 9081 X — X X ET70WP'24115CfR — n�* Rod 4558 X — X X ET70Wp'24115C'R0 White 4732 X — X X 870WP'24115C'NVY White 3552 X — X X 4 E»xnm°w=.eummmm I Wheelock AH, AS, IVIT, RSS, ET Technical Data TD450112EN January 2022 I Wall or ceiling mount models Table 7 Specification and ordering information Horn MT-12/24-R MT-12/24-W Red 5023 X X White 5024 X X X X X X Speaker ET-1010-R Red 3135 X X X ET-1010-W White 3137 X X X ET- I 080-R-ULC-D Red 9834 X ET-1080-W-ULC-D White 9835 X Ij —411717.7 Table 8. Ordering information Model Number Finish Order Code Model Number Finish Order Code Backboxes Gasket kit 1013-R (D Red 5046 WP-KIT N/A 4486 108-W (D White 5047 Flush plates WFPA-R t Red 4698 WFPA-W White 4701 WPSBB-R (D Red 9751 WPSBB-W C) White 3033 WHP-R 4N WFP-W WPBB-R () Red 9014 PBB White 4692 W 'p "y" a W 'I Red 4696 White 4697 Table 9. Mounting options WBB-R Red 2959 Surface Mount Flush Mount WBB-W White 2960 Exposed Mounting Options Conduit Concealed Conduit RSSWP Strobes WPSBB WPSBB + WP-KIT WHIP ET70WP Speaker Strobes IOB IOB + WP-KIT WHP ASWP Horn Strobes WPBB WPBB + WP-KIT WHPA (D 1013, WPSBB and WPBB models include weep holes and plug in the event that moisture may have AHWP Horns WBB WHIP entered the appliance. ET-101 0 Speakers WBB WHIP MTWP Multitone Strobes IOB 10B + WP-KiT WHIP Multitone IOB 10B + WP-KiT WHP Note: Refer to Data Sheet TD450028EN for mounting options EATON www.eaton.com 5 Technical Data TD45O112E0 Wheelock AH,AS, MT, RSS,ET Effective January 2022 Architects and engineers specifications General Weatherproof notification appliances shall be UL listed for outdoor use, Weatherproof strobe appliances shall be listed under UL Standard 1638 (Standard for Visual Signaling Appliances) for Indoor/Outdoor use and UL Standard 1971 (Standard for Safety Signaling Devices for Hearing |mpaired>.The appliances shall beavailable for optional wall mounting orceiling mounting toweatherproof b kboxes using either exposed conduit, concealed conduit, or semi -flush mounting ma recessed electrical box inwalls orceilings using Wheelock mounting accessories. Weatherproof strobe appliances shall be Wheelock BSSWP models or approved equals. The weatherproof strobes shall produce a mini- mum flash rate of 60flaahes per minute over the UL Regulated Voltage Range of 16to 38VDC and shall incorporate a Xenon flashtube, The weatherproof strobes shall boavailable with UL1971 candela ratings up to 185 cd for wall mounting and 177 cd for ceiling mounting. UL 1038 candela ratings up to 180od ot77,F shall be available. The strobes shall operate over an extended temperature range of-4U°F to150,F(-40°Cm08°C)and bnlisted for maximum humidity of8596 RH,Strobe inputs shall bepolarized for compatibility with standard reverse polarity supervision of circuit wiring by Fire Alarm Control Panel (FACP). Weatherproof audibles shall be Wheelock AH models or approved equals, and the weatherproof audible/strobe combinations shall be VVhee|ookASVVP models or approved equals, The weatherproof horns and mu|titone audih|eo shall be listed for Indoor/Outdoor use under UL Standerd404. The horns shall be able to produce a continuous output ore temporal code-3 output that can be synchronized. The horns nheU have at least sound level settings. Horn/strobe combinations aho|| be able to he synchronized on a single NAC. K8u|titone oudib|en shall Wheelock MT models or approved equals. The mu|titona horns shall be able to produce S distinct tones selectable bydip switch and shall have otleast 2 sound level settings. K4u|zitune audible/strobe combinations shall have independent inputs for the audible and strobe, The strobes and Code horns shall boable to be synchronized. Th*eudih|ea shall beable to becoded when operated onaseparate NAC. ASWP auclibles and strobes shall be able to be synchronized on a 2-wire circuit with the ability to silence the audible ifrequired, The strobes on MT muWtono audible/strobe appliances haU be ob|o to be synchronized and shall be able to be operated on a separate circuit from the audibles while the audible circuit is connected to a coded or continuous NAC. When set to Code 3 Horn, the IVIT multitone audibles shall be able tobesynchronized, Weatherproof Speakers and Speaker/Strobes Weatherproof speakers shall be Wheelock ET-1010 models or approved equals, and speaker strobes shall be ET70WP or approved equals. Weatherproof speakers and speaker strobes shall be ULlisted for indoor/outdoor use under UL Standard 148U.All speakers shall provide field oe|eozeb|a taps for 1/0Wto 8VVoperation for either 25VRK4S or70VRMS audio systems and ahoU |nuonourazo a nou|ed back construc- tion foroxtra protection and improved audibility, Speakers shall be listed toproduce uptu94d8Aand shall incorporate avandal resistant grille design. Speaker strobes shall be available for surface or semi -flush mounting to walls or ceilings and shall be listed to produce upnoS3 dBA� When synchronization of strobes or temporal code-3 audib|os is required, the appliances nhoU be compatible with the VYh*e|nok DSK4 sync modules, Wheelock power supplies orother manufacturers panels with built-in Wheelock patented sync protocol. The strobes and embb|en shall not drift out ofsynchronization etany time during operation. Weatherproof mounting | include surface mounting or semi -flush mounting towalls or ceilings. Surface mounted appliances shall mount to Wheelock 1013, VV8B WPBB or WPSB13 weatherproof backboxes using either exposed conduit or concealed conduit. For concealed conduit the weatherproof baokUnxnhan be mounted to a recessed electrical box with VVheelook'aVVP'K|Tto provide a weatherproof seal for the o|ecuioe| box. Semi -flush mounted appliances shall mount toa recessed o|aohoa| box using Wheelock VVFP or WFPA flush plates to provide a weatherproof seal between the electrical box and the appliance. VVEENCOURAGE AND SUPPORT N|CETCERTIFICATION 3-YEAR WARRANTY Eat n ,mmsmv Boulevardnn�*�,oxwoz United States Eaton uw safety & mass notification solutions Long Branch, NJ 07740 Eaton. com/Lifesafetynotification mmnEaton ������� wmmm Reserved ��u°registered trademark. ��m������ �w�."u� �� ��� Publication No. rovoonzsw All other trademarks are property