HomeMy WebLinkAbout22-5220Address: 7116 Silverado Ranch Blvd
ZEPHYRHILLS, FL 33541
Phone: (352) 424-4422
7116 Silverado Ranch Boulevard
Contractor: MODERN CONCEPTS
SOLAR AND ROOFING INC
City of Zephyrhills MOO-
5335 Eighth Street liili`
ZephyrhiUs, FL 33542 ELCMISC-005220-2022
Phone: (813) 780-0020 Fax: (813) 780-0021 Issue Date: 11/15/2022
Building Valuation: $19,761.00
Electrical Valuation: $30,000.00
Mechanical Valuation:
Plumbing Valuation:
Total Valuation: $49,761.00
Total Fees: $328,80
Amount Paid: $328.80
Date Paid: 11/15/2022 3:3936PM
REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first relinspection, whichever is greater, for each subsequent reinspection.
Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies.
=0 KTIT01 I I l=_1 - I �11 ilill
Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
C OR G
PE IT OFFICEL
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
*"1"*P0S1'65UANCE REVISIONS ATTACHED City of Zephyrhills Permit Application Fax-813-780-0021
LHIIIIVe_'" ri1_4f_1;3" HNPZPC�0.-T;-1PC, Building Department
PERMITTI ING @YOLJRPROJ ECTSOLUTIONS, CO;
Date Received a Phone Contact for �Perndftln
sassss
Owner's Name LS!Lg, NATHAN Owner Phone Number L352 124-4422
Ow Owner's AddressF-7116 Silvered. Ranch Blvd, Zphyrhift, FL 33541 ner Phone Number
Fee Simple Titleholder Name L_ ____j Owner Phon—e-Rumber
Fee Simple Titleholder Address
JOB ADDRESS 7116 Silverado Ranch Blvd, za h rhllis, FL 33 49 LOT # 23
SUBDIVISION SILVERADO RANCH PARCEL ID#
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED NEW CONSTR ADDIALT SIGN DEMOLISH
INSTALL REPAIR
PROPOSED USE SFR COMM OTHER
TYPE OF CONSTRUCTION BLOCK FRAME STEEL
DESCRIPTION OF WORK INSTALL RESIDENTIAL ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM
BUILDING SIZE SQ FOOTAGE HEIGHT
BUILDING30,000 VALUATION OF TOTAL CONSTRUCTION
[=ELECTRICAL $ 19,761 AMP SERVICE Ot PROGRESS ENERGY W.R.E.C.
=PLUMBING
=MECHANICAL VALUATION OF MECHANICAL INSTALLATION
=GAS ROOFING = SPECIALTY = OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO
BUILDER COMPANY E;;
SIGNATURE = REGISTERED Y I N;; FEFC.RREN��
Address License #
ELECTRICIAN 121 COMPANY MODERN CONCEPTS SOLAR AND ROOFING INC
SIGNATURE REGISTERED YIN FEE CURREN Y/N
Address License #
PLUMBER COMPANY E
SIGNATURE REGISTERED FEE CU�RREN Y
Address License #
MECHANICAL COMPANY E
SIGNATURE REGISTERED ;;;;� �F.I.URRIEN���
Address License It
OTHER COMPANY E
SIGNATURE REGISTERED Y ;1N ;=FEE =CUR]REN �Y/N
Address License #
RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction,
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & I clumpster, Site Work Permit for subdivisions/large projects
COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction.
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance
SIGN PERMIT Attach (2) sets of Engineered Plans.
*—PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner & Contractor sign bark of application, notarized
If over $2500, a Notice of Commencement Is required. (AJC upgrades over $7500)
Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences (PlottSurvey/Footage)
Driveways -Not over Counter if on public roadways..needs ROW
813-780-0020 City of Zephymills Permit Application Fax-813-780-0021
Building Department
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive
than County regulations. The undersigned assumes responsibility for compliance with any applicable dead restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they
may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and
contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements
may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009,
Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractors) sign portions of the "contractor Block" of this
application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is
not entitled to permitting privileges in Pasco County,
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or
expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that
such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery
Fees must be paid prior to receiving a 'certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final
power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior
to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant,
have been provided with a copy of the "Florida Construction Lion Law —Homeowner's Protection Guide" prepared by the Florida Department of
Agriculture and Consumer Affairs. If the applicant is someone other than the 'owner, I certify that I have obtained a copy of the above described
document and promise in good faith to deliver it to the "owner' prior to commencement.
CONTRACTOR'SIOWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with
all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as
indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all
laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I
understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I
must take to be in compliance. Such agencies include but are not limited to:
Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, WaterMastewater Treatment.
Southwest Florida Water Management District -Wells, Cypress Bayheads, Weiland Areas, Altering
Watercourses.
Army Corps of Engineers -Seawalls, Docks, Navigable Waterways.
Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment,
Septic Tanks.
US Environmental Protection Agency -Asbestos abatement,
Federal Aviation Authority -Runways.
I understand that the following restrictions apply to the use of fill:
- Use of fill is not allowed in Flood Zone W" unless expressly permitted.
- If the fill material is to be used in Flood Zone 'A', it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida,
- If the fill material is to be used in Flood Zone "N' in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit poor to
commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or
other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as
authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from
thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work
authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a
period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to
exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered
abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
DA JURAT (F.S. 117.03)
OWNER OR AGENT �_ CONTRACTOR —
Subscribed and swum to (or affirmed) before me this SuVbc !d and sworn
_b X _ by_
Who is/are personally known to me or hasthave produced V Ware mmwk�
as identification.
RM
Commission No.
Name of Notary typed, punted or stamped
"IM11, CARLY FLANDERS 7", ,YIY
Notary Public -State of :Flori]da
Commission # HH 75532]
b s
My Commission Expires
F
December 29, 2024
Prepared By: Cady Flanders - MODERN CONCEPTS SOLAR AND ROOFING INC
Address: 201 N. FRANKLIN STREET, SUITE 2200, TAMPA FL 33602
Permit No.
Tax Folio/ParcellD: 05-26-21-0100-00700-0230
NOTICE OF COMMENCEMENT
THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter
713, Florida Statutes, the following information is provided in this Notice of Commencement:
SILVERADO RANCH SUBDIVISION PHASES 7, 9B,
1. Description of property: (legal description of property, and street address if available) _11A A — Mi-113
7116 Silverado Ranch Blvd, Zephyftils, FIL 33541
2, General description of improvement: INSTALL RESIDENTIAL ROOF MOUNTED SOLAR PV SYSTEM —
3. Owner information:
& Name and address: KITE NATHAN B & MEGHAN 7116 Silverado Ranch Blvd, Zephyrhills, FL 33541
b. Phone number: 352-424-4422
c. Name and address of fee simple titleholder (if other than owner):
4. Contractor:
a, Name and address: MODERN CONCEPTS SOLAR AND ROOFING INC 201 N. FRANKLIN STREET SUITE 2200,TAMPA FL 33602
In. Phone number: (813) 687-8040
5. Surety:
a, Name and address:
b. Amount of bond $
6. Lender:
a. Name and address:
b. Phone number:
7, Persons with the State of Florida designated by Owner upon whom notices or other documents may be served as provided in Section
713,13(1)(a)7, Florida Statutes:
a. Name and address:
b. Phone number:
8. In addition to himself, Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713,13(i)(b),
Florida Statutes:
a, Name and address:
b. Phone number:
9. The expiration date of the notice of commencement is one (1) year from the date of recording unless a different date is specified:
WARNING TO OWNER: ANY PAYMENTSMADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF
COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CTIAPTFR 713, PART 1, SECTION 713.13,
FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A
NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IT, YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY
BE OOF COMMENCEMENT.
_4 Signature of Owner
or own Printed Name Itle/oKe
STATE OF FLORIDA
COUNTY OF 0 C*— tn
The foregoing at was "kn wldged before me this _10 day of 20 by
(name of person) as (type of authority: e.g., officer, trustee, attorney -in -fact) for
(name of party on behalf of whom instrument was executed), who is is ally known tome or who has produced
"r Notaly Public of Fkxi"
Si in,
v ls� HH 136039
Signature of Notary Public
Xp"s D5MO26
ification Pursuant to Section 92.525, Florida Statutes
Under penalties of perjury, I declare that I have read the foregoing and that the facts stated in it are true to the best of my knowledge and belief.
Signature of Natural Person Signing Above
76 North Meadowbrook Drive
Alpine, UT 84004
Suite 2200
Tampa, FL 33602
Re-. Engineering Services
0|eResidemoe
7118Gi|venadoRanch Boulevard, ZephyrhiUa.FL
11.470kVVSystem
ToWhom kMay Cuncenm.
We have received information regarding solar panel installation on the roof of the above referenced
structure. Our evaluation of the structure is to verify the existing capacity of the roof system and its ability
tosupport the additional loads imposed bythe proposed solar system.
1 . Site visit documentation identifying attic information including size and spacing of framing
for the existing roof structure.
2. Design drawings of the proposed system including a site plan, roof plan and connection
details for the solar panels. This information will be utilized for approval and construction
of the proposed system.
Roof Framing:
Assumed prefabricated wood trusses at 24^oncenter. All truss members
are constructed cnzx*dimensional lumber.
Roof Material:
Composite Asphalt Shingles
Roof
23degneea
Attic Access:
Inaccessible
Foundation:
Permanent
Dead Load
w Live Load =2Opu (reducible)—Opsfatlocations ofsolar panels
~ Ground Snow Load =Ops
° Wind Load based onABCE7-18
o Ultimate Wind Speed =14Omph (based onRisk Category ||)
o Exposure Category C
Analysis performed of the existing roof structure utilizing the above loading criteria is in accordance
with the FBC 2020 (71h Edition) including provisions allowing existing structures to not require
strengthening if the new loads do not exceed existing design loads by 105% for gravity elements
and 110% for seismic elements. This analysis indicates that the existing framing will support the
additional panel loading without damage, if installed correctly.
W.9row.7.7 POP
roof system will adequately support the additional loading imposed by the solar system. This evaluation is in
conformance with the FBC 2020 (Th Edition), current industry standards, and is based on information supplied
to us at the time of this report.
Should you have any questions regarding the above or if you require further information do not hesitate to
contact me.
.................
MODERN CONCEPTS SOLAR
201 N. FRANKLIN ST. SUITE 2200
TAMPA, FL 33602
REVISIONS
DESCRIPTION
DATE
REV
INITIAL DESIGN
10106/2022
t � ray
Og ✓
0 $ ' $ °✓
p}y�
„ a A E
f2�T��Xflf{(iSa¢4Stlit"'S
NA
Wyssling Consulting, PLLC
75 R Meadowbrook Drive Alpine UT 04004
Florida License # RY 4912
Date Signed 10/25/2022
PROJECT NAME & ADDRESS
Zco
W
� � co
SE -) ® D-
W < J
® LU m =
J �
z
CID CL
r W
N
SIGNAi
18. DISCONNECTING MEANS SHALL BE LOCATED IN A VISIBLE, READILY ACCESSIBLE LOCATION WITHIN THE PV SYSTEM
vvvv ® sv® ve a�o-fv�.v
DRAWN BY
EQUIPMENT OR A MAXIMUM OF 10 FEET AWAY FROM THE SYSTEM [NEC 690.13(A)]
F
19. ALL WIRING METHODS SHALL BE IN ACCORDANCE WITH NEC 690.31
PROJECT TO COMPLY WITH THE FOLLOWING:
ER
SHEET NAME
20. WORK CLEARANCES AROUND ELECTRICAL EQUIPMENT WILL BE MAINTAINED PER NEC 110.26(A)(1), 110.26(A)(2) AND 110.26(A)(3).
FLORIDA RESIDENTIAL CODE, 7TH EDITION 2020 (FRC)
COVER SHEET
FLORIDA PLUMBING CODE, 7TH EDITION 2020 (FPC)
21. ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED & IDENTIFIED IN ACCORDANCE WITH
FLORIDA BUILDING CODE, 7TH EDITION 2020 EDITION (FBC)
UL1703
FLORIDA MECHANICAL CODE, 7TH EDITION 2020 (FMC)
SHEET SIZE
2017 NATIONAL ELECTRICAL CODE
22. ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND ANCHOR CONDUIT RUNS AS REQUIRED PER NEC.
FLORIDA FIRE PREVENTION CODE, 7TH EDITION 2020
ANSI B
(FFPC)
11 " X 17"
SHEET NUMBER
PV-1
PROJECT DESCRIPTION:
31 X APTOS SOLAR: DNA-120-MF26 370W MONO MODULES
ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES
DC SYSTEM SIZE: 31 x 370 = 11.470KW DC
AC SYSTEM SIZE: 31 x 290 = 8.990KW AC
EQUIPMENT SUMMARY
31 APTOS SOLAR: DNA-120-MF26 370W MONO MODULES
ROOF #2
31 ENPHASE 1Q8PLUS-72-2-US 29OW MICROINVERTERS
(12) APTOS SOLAR: DNA- 120-MF26
EQUIPPED WITH RAPID SHUTDOWN
370W MONO MODULES WITH ENPHASE
ROOF ARRAY AREA #1:- 274.82 SQ FT.
1Q8PLUS-72-2-US 29OW MICROINVERTERS
ROOF ARRAY AREA #2:- 235.56 SO FT.
EQUIPPED WITH RAPID SHUTDOWN
ROOF ARRAY AREA #3:- 98.15 SQ FT.
(E) TREES
ROOF #3
NOTE: VISIBLE, LOCKABLE, LABELED AC DISCONNECT
(5) APTOS SOLAR: DNA-120-MF26
LOCATED CLOSE PROXIMITY TO UTILITY METER
370W MONO MODULES WITH ENPHASE
(E) FENCE
1Q8PLUS-72-2-US 29OW MICROINVERTERS
EQUIPPED WITH RAPID SHUTDOWN
(E) GATE r
_
--
_-, -- --
13411
O
13
LINE-
PROPERTY
m
6
!I
s
,I
1
2-STORY
HOUSE
Zf
s
03
EXISTING
v ;
DRIVEWAY
0
m
PROPERTY LINE
(
O
APTOS SOLAR: DNA-1 20-MF26
MONO MODULES WITH ENPHASE
)♦
>(INSIDER
(E) UTILITY METER/ MAIN !:
NON-FUSED(N) VISIBLE, LOCKABLE,
LABELED
(LOCATED • PR
A
DESIGN SPECIFICATION
OCCUPANCY:
CONSTRUCTION:
ZONING: RESIDENTIAL
GROUND SNOW LOAD:
c
MODERN CONCEPTS SOLAR
201 N. FRANKLIN ST. SUITE 2200
TAMPA, FL 33602
REVISIONS
DESCRIPTION
DATE
REV
INITIAL DESIGN
M06I2022
! �i4iftl
YSS
N 1558
STAT OF ,
i
%i•
d{fig
ONAL
,111tt#$Emll%"�
y lil Consulting, PLLC
76 N Meadow rook Drive Alpine UT 04004
Radda License # RY34912
Date Signed 10/25/2022
PROJECT NAME & ADDRESS
Z
Uj _j
�
z O LL
Z w Q > J
LU m =
z
cfl �
�- W
DRAWN BY
ESR
SHEET NAME
SITE PLAN
SHEET SIZE
ANSI S
11" X 17"
SHEET NUMBER
PV-2
' MODULE TYPE DIMENSIONS & WEIGHT
NUMBER OFMODULES =31MODULES
MODULE TYPE =APTOSSOLAR: Dm8-12O-MF2057UVVMONO MODULES
MODULE WEIGHT =45A9LBG/2U.5KG.
MODULE DIMENSIONS =0915^x4O31''=18-O3SF
ROOF#3 ��
�N.^
IN ` ' APTOS SOLAR: -' -'—F-- RmoF#n
-7—'MONO MODULES WITH ~``'''~E PITCH zz`
|Q0PLUS-72-2-US 290W MICROINVERTERSxzJW 357
EQUIPPED WITH RAPID SHUTDOWN
39.-3"
IUN
331-011
- (E) SUB PANEL (INSIDE GARAGE)
(E) UTILITY METER/ MAIN COMBO
1 ROOF PLAN & MODULES
nOOF#c
PITCH zu��
ROOF DESCRIPTION
ROOF TYPE
ASPHALT SHINGLE
ROOF LAYER
I LAYER
ROOF
#OF
MODULES
ROOF
PITCH
AZIMUTH
TRUSS
SIZE
TRUSS
SPACING
ARRAY AREA & ROOF AREA CALC'S
TOTAL PV ARRAY
TOTAL ROOF
ROOF
AREA
AREA
AREA COVERED BY
(77) EVERESTK2SYSTEMS
SPLICE FOOT XLATTACHMENT
ROOF #2
370W MONO MODULES WITH ENPHASE
ROOF #1
70W MONO MODULES WITH ENPHASE
40 91co
APT0S8OLAR:
DNA-1204MF26
J7OVVMODULES |
MODERN CONCEPTS SOLAR
REVISIONS
DESCRIPTION
DATE
REV
INITIAL DESIGN
10/06/2022
ATE F
Florida License # RY34912
Date Signed 10/25/2022
PROJECT NAME & ADDRESS
Uj
co
LU
DC SYSTEM SIZE: 31 x 370 = 11.470KW DC
AC SYSTEM SIZE: 31 x 290 = 8.990KW AC
(31) APTOS SOLAR: DNA-120-MF26 370W MONO MODULES
WITH (31) ENPHASE IQ8PLUS-72-2-US 29OW MICROINVERTERS
EQUIPPED WITH RAPID SHUTDOWN
LOCATED UNDER EACH PANEL (240V)
CIRCUIT LEGENDS
----------- CIRCUIT #1
CIRCUIT #2
— -- --- CIRCUIT #3
N
'4L S
S
ELECTRICAL
PV-4 SCALE: 1/8" = V-0"
BILL OF MATERIALS
EQUIPMENT
QTY
DESCRIPTION
SOLAR PV MODULES
31
APTOS SOLAR: DNA-120-MF26 370W MODULE
MICRO INVERTERS
31
ENPHASE IQ8PLUS-72-2-US 29OW
MICRO€NVERTERS EQUIPPED WITH RAPID
SHUTDOWN
SOLADECKS
3
SOLADECKS
COMBINER BOX
1
ENPHASE IQ COMBINER X-IQ-AM1-240-4/4C
120/240VAC, 1�, 3W 125A RATED BUS BAR, NEMA
3R SOLAR LOADS ONLY UL 1741 COMPLIANT
BREAKERS
3
20A BREAKERS
AC DISCONNECT
1
NON -FUSED AC DISCONNECT 60A ,
240V NEMA 3R, UL LISTED
RAIL
20
EVEREST K2 SYSTEMS CROSSRAIL 44-X 166"
SPLICE
4
SPLICE FOOT XL RAIL CONNECTOR
MID MODULE CLAMPS
40
MID MODULE CLAMPS
END CLAMPS
44
END CLAMPS/STOPPER SLEEVE
GROUNDING LUG
11
GROUNDING LUG
ATTACHMENTS
77
EVEREST K2 SYSTEMS
SPLICE FOOT XL ATTACHMENTS
CIRCUIT #2
(11 MODULES)
LEGEND
I jB - JUNCTION BOX
-SOLADECK
-INVERTER
iI - COMBINER BOX
- AC DISCONNECT
- UTILITY METER
I_
MAIN SERVICE PANEL
- VENT, ATTIC FAN (ROOF OBSTRUCTION)
- ROOF ATTACHMENT
— -TRUSS
- CONDUIT
MODERN CONCEPTS SOLAR
201 N. FRANKLIN ST. SUITE 2200
TAMPA, FL 33602
REVISIONS
DESCRIPTION
DATE':
REV
INITIAL DESIGN
10/06/2022
N
A CF
ORI
Wyssling Consulting, PL C
76 N Meadowbrook Drive Alpine UT 84004
Florida License # RY34912
Date Signed 10/25/2022
PROJECT NAME & ADDRESS
z
w
0� J
Z d LL
z w Q>J
¢ ® Cz I
z ® gym=
dw
C/'
W
ti N
DRAWN BY
ES
SHEET NAME
ELECTRICAL PLAN
SHEET SIZE
ANSI B
11" X 17"
SHEET NUMBER
PV-4
4
mm
I
WIN 11 1R.T41l Q INS I- •-•
s ` s I V1
•
• q ■Ka I NFAM
MC. S"'IAR
MODERN CONCEPTS SOLAR
201 N. FRANKLIN ST. SUITE 2200
TAMPA, FL 33602
REVISIONS
Y DESCRIPTION
DATE
REV
INITIAL DESIGN
10/0612022
ATE
�gqqR t �g {{ �$qg
V �'p
Wyssling Consulting, PLLIC
76 N Mead brook Drive Alpine UT 34004
Fta6da License # RY34912
Date Signed 10/25/2022
PROJECT NAME & ADDRESS
z
J LIJ 0
®® ) J
3. 0 LL
Z Lj < U)
< C) J
_J
> o _
< LLJ J
Z
r LLj
N
DRAWN BY
-S
SHEET NAME
STRUCTURAL DETAIL
SHEET SIZE
ANSI B
11" X 17"
SHEET NUMBER
PV-5
DC SYSTEM SIZE: 31 x 370 = 11.470KW DC
AC SYSTEM SIZE: 31 x 290 = 8.99OKW AC
(31) APTOS SOLAR: DNA-120-MF26 370W MONO MODULES
WITH (31) ENPHASE IQ8PLUS-72-2-US 29OW MICROINVERTERS
EQUIPPED WITH RAPID SHUTDOWN
LOCATED UNDER EACH PANEL (240V)
(2) BRANCH CIRCUITS OF 10 MODULES AND
(1) BRANCH CIRCUIT OF 11 MODULES CONNECTED IN PARALLEL
APTOS SOLAR: DNA-120-MF26
370W MODULES
BRANCH #1
1 2 3 0 0 0 9 10
77 +
✓` , pis ii �r 0 0 0
BRANCH #2
1 2 3 0 0 0A I 10 11
— ffEll- __ _ -
" ,i✓ :,ram 0 0 0 t
BRANCH #3
1 2 3 0 0 0 9 10
AT i
BRANCH
TERMINATOR
(ET -TERM) ENPHASE IQ8PLUS-72-2-US 290W
MICROINVERTERS EQUIPPED WITH
RAPID SHUTDOWN
LOCATED UNDER EACH PANEL (240V)
A DIAGRAM
SCALENTS
INTERCONNECTION NOTES:
1. INTERCONNECTION SIZING, LIMITATIONS AND COMPLIANCE
DETERMINED IN ACCORDANCE WITH [NEC 705.121, AND [NEC 690.591
2. GROUND FAULT PROTECTION IN ACCORDANCE WITH [NEC 215.9],
[NEC 230.951.
3, ALL EQUIPMENT TO BE RATED FOR BACKFEEDING.
4. PV BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE
BUSBAR RELATIVE TO THE MAIN BREAKER.
DISCONNECT NOTES:
1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN
THE SWITCH IS OPENED THE CONDUCTORS REMAINING LIVE ARE
CONNECTED TO THE TERMINALS MARKED "LINE SIDE" (TYPICALLY
THE UPPER TERMINALS)
2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY
PERSONNEL, BE LOCKABLE, AND BE A VISIBLE -BREAK SWITCH
3. DISCONNECT MEANS AND THEIR LOCATION SHALL BE IN
ACCORDANCE WITH [NEC 225.311 AND [NEC 225.32].
GROUNDING & GENERAL NOTES:
1. PV GROUNDING ELECTRODE SYSTEM NEEDS TO BE INSTALLED IN ACCORDANCE
WITH [NEC 690.431
2. PV INVERTER IS UNGROUNDED, TRANSFORMER -LESS TYPE.
3. DC GEC AND AC EGC TO REMAIN UNSPLICED, OR SPLICED TO EXISTING
ELECTRODE
4. ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT IS
FOUND TO BE INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINAL
INSPECTION.
5. SOLADECK QUANTITIES, AND PLACEMENT SUBJECT TO CHANGE IN THE
FIELD - SOLADECK DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE
TYPE TRANSITIONS.
6. AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER
AC DISCONNECTING MEANS IS LOCATED WITHIN 10' OF SERVICE DISCONNECT.
7. RACEWAYS AND CABLES EXPOSED TO SUNLIGHT ON ROOFTOPS SHOULD BE
INSTALLED MORE THAN 7/8" ABOVE THE ROOF USING CONDUIT SUPPORTS.
RACKING NOTE: TO UTILITY GRID
1. BOND EVERY RAIL WITH #6 BARE COPPER L1 1_2 N
ENPHASE IQ COMBINER
X-IQ-AM1-240-4/4C 120/240VAC,
I�, 3W 125A RATED BUS BAR,
NEMA 3R SOLAR LOADS ONLY
UL 1741 COMPLIANT
IQ ENVOY: PER
MANUFACTURER —
SPECIFICATIONS, EITHER IQ ENVOY
10A OR 15A BREAKER IS i
SUITABLE FOR USE j PV AC DISCONNECT
i 15A/2P i 240V. 10, 3W
� o_ I 60A RATED
h NEMA 3R
SOLADECK,
600V NEMA 3R,
UL LISTED
20A/2P
L2 h
20A/2P €
L1
i
L2 h
20A/2P
3 ,
Nh
i L
G G
LINE
LOAD
G_k
I
1 ~
G
VISIBLE, LOCKABLE,
LABELED AC DISCONNECT
LOCATED CLOSE PROXIMITY
TO UTILITY METER
x
pX1 0=25
BI-DIRECTIONAL
UTILITY METER
120/240V 10, 3-W
(E) MAIN BREAKER TO
HOUSE 240V, 20OAl2P
(E) MAIN SERVICE
PANEL,SQUARE D
200A RATED, 240V
L11L2 NI G,
I
[ (E) SUB PANEL,
I SQUARE D-HOM,
225A RATED, 240V
LOAD/LINE SIDE
INTERCONNECTION
50A/2P AT MAIN PANEL/SUB-PANEL
hPER ART. 705.12
BACK -FEED BREAKER
N REF
2017 NEC 705.12(B)(2)(3)(b)
G,
GEC
EXISTING GROUNDING
ELECTRODE SYSTEM TO EARTH
REF. NEC 250.52, 250.53(A)
QTY
CONDUCTOR INFORMATION
CONDUIT TYPE
CONDUIT
SIZE
(6)
#12AWG -
ENPHASE ENGAGE CABLE
(L1 & L2 NO NEUTRAL)
N/A
N/A
(1)
#10AWG -
CU,THWN-2 GND
(6)
#10AWG -
CU THWN-2
(1)
#10AWG -
--
CU THWN-2 GND
EMT OR LFMC IN ATTIC
3/4"
(2)
#8AWG-
CU,THWN-2
(1)
#8AWG -
----------- .........
CU THWN-2 N
EMT, LFMC OR PVC
3/4"
(1)
#10AWG -
CU THWN-2 GND -
(2)
#8AWG -
CU,THWN-2
(1)
#8AWG -
CU THWN-2 N
EMT, LFMC OR PVC
3/4"
CU,THWN-2 GND
MODERN CONCEPTS SOLAR
201 N. FRANKLIN ST. SUITE 2200
TAMPA, FL 33602
REVISIONS
DESCRIPTION
DATE
REV
INITIAL DESIGN
10/06/2022
$ ! 1ftJ1
mid
.
. ` •yr
'
ST
° `
fi
fop . I N %
fgj��£ftiFifii$iktli
,
Wyssling Consulting, PLLC
76 N Meado brook Drive Al ine UT 84004
Florida License # RY34912
Date Signed 10/25/2022
PROJECT NAME & ADDRESS
r
z L0
�M
S U
z Q ® U
Q Q [if J J
Lu CO
W J
`z
Cfl
LLi
DRAWN BY
ESR
SHEET NAME
ELECTRICAL LINE DIAGRAM
SHEET SIZE
ANSI
11" X 17"
SHEET NUMBER
PV-6
LABEL-1:
LABEL LOCATION:
AC DISCONNECT
u µ011
v:
ELECTRICAL SHOCK HAZARD
TERMINALS ON THE LINE AND LOAD SIDES MAY
BE ENERGIZED IN THE OPEN POSITION
LABEL- 2:
LABEL LOCATION:
AC DISCONNECT
COMBINER
MAIN SERVICE PANEL
SUBPANEL
MAIN SERVICE DISCONNECT
CODE REF: NEC 690.13(B)
LABEL- 3:
LABEL LOCATION:
UTILITY METER
MAIN SERVICE PANEL
SUBPANEL
CODE REF: NEC 705.12(C) & NEC 690.59
LABEL-4:
LABEL LOCATION:
MAIN SERVICE PANEL
SUBPANEL
MAIN SERVICE DISCONNECT
COMBINER
CODE REF: NEC 110.27(C) & OSHA 1910,145 (f (7)
1
PHOTOVOLTAIC SYSTEM CIRCUIT IS
RACKFEED
LABEL-5:
LABEL LOCATION:
MAIN SERVICE PANEL (ONLY IF SOLAR IS BACK -FED)
SUBPANEL (ONLY IF SOLAR IS BACK -FED)
CODE REF: NEC 705,12(B)(3-4) & NEC 690.59
POWER SOURCE OUTPUT
CONNECTION. NOT
RELOCATE THIS
OVERCURRENT
LABEL- 6:
LABEL LOCATION:
MAIN SERVICE PANEL (ONLY IF SOLAR IS BACK -FED)
SUBPANEL (ONLY IF SOLAR IS BACK -FED)
CODE REF: NEC 705.12(B)(3)(2)
1 i ` i i
i i N 1
TURN RAPID SHUTDOWN
SWITCH TO THE
"OFF" POSITION TO
SHUT DOWN PV SYSTEM
AND REDUCE
SHOCK HAZARD
IN THE ARRAY
SOLAR ELECTRIC
P✓PANELS
LABEL- 7:
LABEL LOCATION:
AC DISCONNECT
CODE REF: FFPC 11.12.1.1.1 A & NEC 690.56(C)
LABEL- 8:
LABEL LOCATION:
AC DISCONNECT
CODE REF: NEC 690.56(C)(2)
LABEL- 10:
LABEL LOCATION:
MAIN SERVICE PANEL
SUBPANEL
AC DISCONNECT
CODE REF: NEC 690.54
LABEL- 11:
LABEL LOCATION:
MAIN SERVICE DISCONNECT (ONLY IF MAIN SERVICE DISCONNECT IS PRESENT)
CODE REF: NEC 690.13(B)
MODERN CONCEPTS SOLAR
201 N. FRANKLIN ST. SUITE 2200
TAMPA, FL 33602
REVISIONS
DESCRIPTION
DATE
REV
INITIAL DESIGN
10/06/2022
���.��54 $ fyptpppp
M S '
Wyssling Consulting, PLLC
76 N Meadowbrook Drive Alpine UT 8404
Florida License # RY34912
Date Signed 10/25/2022
PROJECT NAME & ADDRESS
U z L0
wl 0Y
_j
W J
Q LL
Q ®
J
< IK J —_I
_
= LI coT
U) M
c0 i L
LLI
I`- N
DRAWN BY
SHEET NAME
LABELS
SHEET SIZE
ANSI B
11" X 17"
SHEET NUMBER
PV-8
DNA TM
_V�
120
30 Year 3X IEC RETC Top
I, Warranty i
I Standards 'Performer
L
3 14() L-)e i.vd- S! 21"
Santa "fara, C!, 9Sj�,4,
opt S mcn
Solar for Innovators I
Designed & Engineered in Silicon Valley
370W 136 1360W
C
e ri i, o!, e,,
s
6:2
A,—
tntertek C E AS --
98%
97%,
907%
KI-7%
80,2%
76,7%
Linear Performance Warranty
Year 10 years 20years 25yaars 30years
Aptes Warranty 0 industry Standard
DNA
Ap�.,. thle'!,,,,h-- t,. —: k_ hargEs e4rho"",
Solar for inniovators
Certifications
tntertOk C E
*4 eS
V
aptc)s
MC
S'�' IAR
T
MODERN CONCEPTS SOLAR
201 N. FRANKLIN ST. SUITE 2200
TAMPA, FL 33602
REVISIONS
DESCRIPTION
DATE
REV
INITIAL DESIGN
10/06/2022
PROJECT NAME & ADDRESS
T- T-
C) -t
z L0
C11)
LL1 0-1
0 0
z C) C/)
Z
LLI <
>
<
0 ly- -j
L>L1
Z75-
<
Uj
z
(0 12—
LLJ
N
DRAWN BY
ESR
SHEET NAME
EQUIPMENT
SPECIFICATION
SHEET SIZE
ANSI B
11 " X 17"
SHEET NUMBER
PV-1 1
Commonly used oriole as lnNist
iV
23:5 - 350 235-440
Module cornGlaflbrfir,'y
60r1t.e hart -cell fo-ce t.20 hsl#±-=-e!, 66-.cell/1W ref -rofi aal 72 ciel/144
i'<li'-„erl
Yatlr4i:.`esti!}c"
a
25 --48 25 - 5V
killn/otaxcanta Vc:Hace..
x
30/48 .30/58
Max rnyrut Do votrarrie
;C 60
4
Max Do curxirla Incorpifix dct
A:
15.
p
overvottagra Class Dc port
it
DO portdaakfi�ed curteat.
O
?V array configuration
r
'x7 ungrourr ed array. No andittn, ;af DC:. aide: protection required. AC side protention ohrurres rr.ax 23A pnr draraoi c:r. urt
_
Peakrewrit power
V
245 300
Max cor;iiEEu u9 rutpo p=:fvour
VA
240 2�e
N ;srinai €:3 itago/°a;i; t
'V
2.0 21-2. f
M a A orrrhn',ousour it Currept
A
'E.0 1,21
icroinverters
ionsixai e-Wer7cv,
t€z
60
Easy to install
Extended r ec se cy.a s
Er
50- k35
Our ne'rrest 106 Microirwarters are The industry s first micrcgrid-forming, sciftalare-
Lightweight and compact with
AC" fault
decried mscroinverters with split -phase power conversion capabilsty to convert DC
plug-n-play connectors
shot, circurt cic rent over'
3 {c€ea
Arm
2
power to AC power efficiently. The brain, of the semiconductor -based microinverter
' �'C1.3N�t' Line Communication
Max unrrs per20 A r 7..a..cncircuit'
16 ,3
is our prop• istary application- Specific integrated circuit (ASIC) which enables the
(PLC) between components
Total har it soha ion
<5%
micro€nverter to operate in grid -tied or off -grid modes, This chip is built in. advanced
dSnm. technolc ci riv:th highs speed ital logic and has super -fast response tierces
Faster ir;stallation terth simple
A
0iervoltage cases AC port
fi
to changing loads and grid events, alleviating constraints on battery Sizing for home
tiro -wire Cabling
AC pertbaclifeed cur£eni
30
energy systems.
:''JJtvr tci^iGP ?TiT: Vim,
4.3
High productivity and reliability
whit -,fed power factor #aisustafsie)
0,85 teoulny 0,& khoerg
Produce power even when the
Peak ofr^rtency
t,
9's.5
7 .r
grid is do
.. .'-
CECf.areghtedeif' iency
%
97 9
'
More, that one rr'#l[on Cumulative
hours of testing
Ntild-tare Pcwsr creournr,.thrt
,MW
60
�
Class it doable -insulated
enclosure
iitT:xSk;fiY :er=.2caratute rarr€��.
-�°(:fC3 +1:ip`.L'i`�v'�E4Gt.+s�l``�
part of the EnvioseE argil R sto Me on;s, I06 Series Micnonowelsiedefinee relsib,tity
Micnonver,ers arnegraro v hop crpha„e U Ratter- avrolarys vt's. f rrore riain orve million curuap:°ve
tJx3l p
Opts nitd for the latest
Refartive f^m,dtoranirp
,>°
4tw 100%(con er�.rrgi
E aX:ai,: r i(.2 Geenso, a {? the E`tpra3o iz.'y`."} (nil fL.1(irs Y#Gll 4 al rsv£± on rest iiEg or,div`. as; +Y' i rld ;PS „Y
4 €
modules
- f". �'}C£C,:f'v 9 i J�
ak'...'' Kxrxt€va.., sotsare. �,. IEd iIRC.,p iN"?�etr R: $t 37xcf C J,?t„,. 25 sec- ..
powered i'V
212 !1"{MI(Prr5 r Y)x t,,.rioff') X.'`.,,,L mm 0.2')
Micrac rid -forming
trPLos
12,38 i
m S:
Complies with the latest
Ccivl,ng
Natural corn ectson .oc runs
grid support*'
ave Net ;ro ^uus
t
{advanced
Remote automatic updates for
�
p, , €o
�kur ndegr
pr_,3
the latest grid requirements
E or A {a
Cfct;..a Il ..^5.,is iv-C3t4,i..,-.. 4Urf S4C{t "2Si.3?'a.,. i£u" ff€,?..Fft; e,:a.:CiSute•
Corrrier:l PV nxidLAx, qurekly'. and eatAy ro KH CeresNficr@„,i{2.� i4#i Y f{'Es�'i iEi9 Ff•* � L 7. a �,a`
Cciitt uralgle to support i
� ��
.a.,v c s.. �x.�.teiariCL`<, starter pVRapid aNsaC'r^w ^a{s taricc c r�tn
Env ist,-rccarespry/€2Jexpcsure, rat rot
NEMATfpebfeuvroor
cable wit h, „lug ,.. ptat MC4cooneu„ors. soroos r c7uto kina, when irotaffed according *o
range of grid profiles
rra ,.Arc.mzer s r„ uc t;r ru-
MeetsCA Rule 2l (L)L 17 -SA
CIt Rote 2#. tt}Lntg,_SA't. i,`L 62109-1:iL#741?€EEE154. PO•G Part 15 Class 6, EOES:-0003 Class R., CAN1C`-SAWAWA--tiy.
requirenaerits
Ceriaftaaticr.?>
"€ hia product is UL Listed as PV Rapid Slat - ran EqurPn er and carrfv,m e with NEC: "s'i3'r4.. NEC 2017, and NEC 2020 sec it n
690,12arel C221-2018 Rule -218 Road.Siiirdoernof P11Spoons, €ts, ACsni DO: corcir.omols, axien installed acccnfin In,
..,;;:<2EnphaseEnengiiAflrypltsreserved, Enprias-e,tre-E phase logo.
'Or.y;~:irc-r shifted wth,i(lS _tem Controller 2,
rianu'facturersnsnoctrons.
Tarr e are .sadrcnar'ks _t E.,PnaSe E fctg`i,. InC.Dani sutuiern locharrge
r_et.. UL.174 ..
t
7 d 1Tn`c �Yf Jt" £kt', rai �' { 'lip
-
trC,.r p ty u.,Tc aS hL*g3 lrr'S k'C'p'�i 25;,. O iud'Ji2 CC+�,a ,btrs }`
2) Maximum intr. uru inpirst `3o curiser
s').6A 3) kernirof can be errwndea Saone rfu „anal ffniquirad
5P- .3 L-= - J,. 2 ' 2-UJ i
arEaCi $ •
virea 6E tt y. (4) s,rr {;s norwry. Refer 4 acal
,rilvin of i-nicroi verters set oarich in Your or i 2 t =r: ii`J-. CyCl-e'J-17
MODERN CONCEPTS SOLAR
201 N. FRANKLIN ST. SUITE 2200
TAMPA,
FL 33602
REVISIONS
DESCRIPTION
DATE
REV
INITIAL DESIGN
10/06/2022
PROJECT NAME & ADDRESS
= r
U �
W
J
Uj cl�
Y
U 0 LL
LLI daJ
LU e " EE
>
!
61
LL!
v{P�
LIJ
N
DRAW+NpBY
ESR
SHEET NAME
EQUIPMENT
SPECIFICATION
SHEET SIZE
ANSI B
11" X 17'
SHEET NUMBER
PV-12
it z n Ing; On S, cu!
rA A
s I rr,
IV, Uclln inar
I b, I I I , 4 4/4 -C'
X-IQ-AMl-240-4
X-1Q-AM71-2404C
7�cr n-ior-e 3oout Enqpi ase offerings, vsft enpha,�ecArn,
S,n a t
r, �'i ,...sue. ,,,I cr bo r',-�!,� ' -.e il r'ia 1 rl() d�-
OC E L� Or" M, I'v" -, 0
essr'l4eld �o Er ph_a, e �r� B
— � 3 "1 y
aesthe',_ics arrm, deflect hea'
F k-'- $ k-e'vcrk�pperrs
P,
ovides
Rehabie
L""j_-U'e 'N"R-L N"","Mvp33-P
F:vkyt,'.-,, iqrny!,E�d �ja'ranl-"
ar, !abor
zj ENPHASE
Enphase IQ Combiner 4/4C
MODEL NUMSEP
CsbFMell_ 4
L pr,
rmu,,acm-.,q rcrure a sd"', „�Q sav'e'-V
0 X� Sy'n�m 8"-xfT'0 def"'ac" nea'z
'V r"" . ,e ..,.ram
�. i 2, � 2 2 2, ir, ,, es, grpr,""se Y"' t"de C r_ r��r 'n��dr.'n
fl
x sr"eq' �'3 rmatc� The Q, [ka?IEr f arc bo
ACCESSORIES AND PEPLACEIVIENT PARTS ",o� mc4rderi, order separatehO
Ir"Ounes CON� 5"', an"', GS w"Ift S yea, ErprFnr aoiaz prarr !_.,r'
Efrselllb!e "ites
Ur LIVIDDEM, edl-re"sp-05; -4G 1',arral, I 'EAM" carhrlw
4G us�d LTE-Mll ce�iux mcralem, yea- ATFT cr,33a ;dm
BR?j5 M240, �rZ S
8P 2 2 4
K,
�R K 2", 'r 2, p 2C Sk 2
Ce� f
Fr
4
X-PLUG-1Z, 3 0
YA w
ELECTRMAL SPECIFICATiONS
Branch ,�cuils endl f
Fnvvibre'ake'
,'rA A,
iJp ro f_ia -M' E'-r or ""R r3e, ,Es 'w_a*'ef
.Si
"7""" �c�" '31��itls
110A �_A "_al�irll'; Glk' 'S�en� nrr� won
A' cn d r,-
U'onsumw`r�f)n
FAECHAWCAL DATA
37 ce 45 x 16 8 „"75' � '�9 "x 6 63'i H,e(53 S wqrl nnormuing
b,l
Amb�t�nq �en'm�� w jq e "'n cre -40' S �461 401 1 l 6�
NEN",A
to nnore about E:'Dhase of"",,�rrrnmssit cnpbaSA, c= N-1/
MC.
S':LAR
MODERN CONCEPTS SOLAR
201 N. FRANKLIN ST, SUITE 2200
TAMPA,
FL 33602
REVISIONS
DESCRIPTION
DATE
REV
INITIAL DESIGN
10/0612022
PROJECT NAME &ADDRESS
w
z L0
CY)
<
_j
ce)
W 171K
_j
C.) LL
Z r)
co
z
w < >0
<
0 w I
LLJ rr,
Z3
<
Lij Q
z
U)
(0 D_
Lu
ti N
DRAWN B
ESR
SHEET NAME
EQUIPMENT
SPECIFICATION
SHEET SIZE
ANSI B
11 " X 17"
SHEET NUMBER
PV-1 3
C.'rossl3all LILI-X
i
Mechanical Properties
-A
6000 Series Almmirlun-,,
3240 MPai
0. 14 90 0, 3 7 8 5
n r, � �'�
0287, '-,
Dimensions in [mrnl Inches
s Strucn.irai vakies and span cha!is deterrnine,-.1 in accovdiance Des�qn Manua; ano ASCE 7-16
U,270'3 ustled System, fox Ffre and Bondirig
MC.
S' 'LAR
T
MODERN CONCEPTS SOLAR
201 N. FRANKLIN ST. SUITE 2200
TAMPA,
FL 33602
REVISIONS
DESCRIPTION
DATE
REV
INITIAL DESIGN
10106/2022
PROJECT NAME & ADDRESS
w
z Lr)
C")
<
_j
cy)
W cl�
-j
(-) o LL
Q (f)
Z
UJ
<
LLJ
>
<
Lij -j
z
ui
N
DRAWN BY
ESR
SHEET NAME
EQUIPMENT
SPECIFICATION
SHEET SIZE
ANSI B
11" X 17"
SHEET NUMBER
Pit-14
We support PV systems
Formerly Everest Solar Systems
Splice Foot XL
11
Mc.
S LAR
MODERN CONCEPTS SOLAR
201 N. FRANKLIN ST. SUITE 2200
TAMPA,
FL 33602
REVISIONS
DESCRIPTION
DATE
REV
INITIAL DESIGN
10iW2022
PROJECT NAME & ADDRESS
= r
L}
CY)
S2
0 LL
Z
c/)
.Z
LLI Q
Q
0 �m�
i
0
CO [L
w
IN
BRAWN BY
ES
SHEET NAME
EQUIPMENT
i SPECIFICATION '
SHEET SIZE
ANSI B
11" X 17"
SHEET NUMBER
P-15
0 Stamped Seamless Construction
* 18 Gauge Galvanized Steel
* Powder Coated Surfaces
# Flashes into the roof deck
0 5 Centering dimples for entry/exit
fittings or conduit
# 2 Position Ground lug installed
# Mounting Hardware Included
'_Fuse holders and termorou blocks
added it 'hA. field RIUSt be UL hSted of
recognrzed and meet 600VDC 30 AMP
1! JO for hose holders, 600V gat? AMP
0C for rail mounted terminal blocks
d 600 V 175 AMP 90C for Power
Distribution E oyes. Use Gopperftre
Coilductors,
StilaDet k Model SD 0783
Available Models,
Model Sly 0783 - (Y fixed Dirt Rail)
Model SD 0786 - W slotted Din Rail?
Models SD 07 41 and SD 0786-41 are labeled and ETL listed UL STD 1741
according to the UL STD 1741 for Photovoltaic combiner e nrdosu es.
Max Rated - 60OV C. 120AMPS
Model SC 07 3 3"° Fixed Din Rail fastened using Norlock System
*Typical System Configuration
4- Din Rail Mounted Fuse Holders 600VDC 3SAMP
1- Pooter Distnbution Suck 60OVv3C 175AMP
1- Bus Bar with UL lug
Model SC 078641 1 S" Slotted Din Rail fastened Using steel Muds
"Typical System Configuration
- Din, Rail Mounted Fuse Holders 60OVDC 30 AMR
4- Din Rail Mounted Terminal Blocks
BUS Bars with UL lug
condurl or fittings, da e is
center dimpled for tstfing
locations,
Model SO 078-4- 1, wired voth Model SO 078 t, }aired rtftf
Din Rail mounted Base holders, Din Rail mounted fuse guiders.
hus bar and privier distrib Lion to =rsal Mucks and bus bars,
block.
RSTC Enterprises, Inc- 2219 Heinnste d Road . Eau Chare, Wt 54703
Or produ t information Gait 1(3 ) 3 7-77 2
MC.
S",IAR
MODERN CONCEPTS SOLAR
201 N. FRANKLIN ST. SUITE 2200
TAMPA,
FL 33602
REVISIONS
DESCRIPTION
DATE
REV
INITIAL DESIGN
10/06/2022
PROJECT NAME & ADDRESS
= r
U �
W
Z
W < cY)
® LL
Z
W®C/)
W Co 2
Uj
co W
W
h— N
DRAWN BY
ESR
SHEET NAME
EQUIPMENT
SPECIFICATION
SHEET SIZE
ANSI
11" X 17"
SHEET NUMBER
PV-16