Name: GRALA LIBBY
Address: 38720 Granger Lane
ZEPHYRHILLS, FLORIDA 33542
5335 Eighth Street
Zephyrhills, FL 33542
ELCMISC-005221-2022
Phone: (813) 780-0020
Fax: (813) 780-0021
Issue Date: 11/15/2022
acement/Misc
Permit Type: Electric Service Replacement/M
Class of Work: Add/Alter Residential
Building Valuation: $20,444.00
Electrical Valuation: $30,000,00
Mechanical Valuation:
Plumbing Valuation:
Total Valuation: $50,444.00
Total Fees: $332.22
Amount Paid: $0.00
Date Paid: 11/15/2022 3:39:36PM
Electrical Permit Fee $190.00 Building Permit Fee
38720 Granger Lane
MKIMINk 10121KOAM 111,21LOW
..........
. . . . . . ... z
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
1A
NT RE PE IT OFFICE
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED IN PECTIO
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
$142.22
Modern Concepts Solar
201 North Franklin Streel
Suite 2200
Tampa, FL 33602
76 North Meadowbrook Drive
Alpine, UT 84004
Re-. Engineering Services
Libby Residence
38720 Granger Lane, Zephyrhills,
9.315 kW System I
1 . Site visit documentation identifying attic information including size and spacing of framing
for the existing roof structure.
2. Design drawings of the proposed system including a site plan, roof plan and connection
details for the solar panels. This information will be utilized for approval and construction
of the proposed system.
Roof Framing:
Assumed prefabricated wood trusses at24"oncenter. All truss members
are constructed of2x4dimensional lumber.
Roof Material:
Composite Asphalt Shingles
Roof Slope:
22degreea
Attic Access:
Inaccessible
Foundation:
Permanent
Dead Load
~ Live Load =2Opaf(roducib|e)-0pofedlocations ofsolar panels
° Ground Snow Load =8pe
• Wind Load based onASCE7'1G
o Ultimate Wind Speed =14Omph (based onRisk Category ||)
• Exposure Category B
Analysis performed of the existing roof structure utilizing the above loading criteria is in accordance
roof system will adequately su port the additional loading imposed by the solar system. This evaluation is in
to us at the time of this report.
Should you have any questions regarding the above or if you require further information do not hesitate to
contact me.
Florida License # RY34912
Date Signed 10/O7/2U22
MW
ROOF MOUNT
SYSTEM
23 MODULES -ROOF MOUNTED - 9.315 KW DC, 6.670 KW AC
PROJECTPHOTOVOLTAIC
DATA
GENERALNOTESVICINITY
MAP
PROJECT
38720 GRANGER LN,
1. ALL COMPONENTS ARE UL LISTED AND CEC CERTIFIED, WHERE WARRANTED.
ADDRESS
ZEPHYRHILLS, FL 33542
2. THE SOLAR PV SYSTEM WILL BE INSTALLED IN ACCORDANCE WITH ARTICLE 690 OF THE NEC 2017.E
OWNER:
GRALA LIBBY
'$
3. THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTED PRIOR TO PARALLEL
OPERATION.
DESIGNER:
ESR
4. ALL CONDUCTORS OF A CIRCUIT, INCLUDING THE EGC, MUST BE INSTALLED IN THE SAME RACEWAY, OR CABLE, OR
_
OTHERWISE RUN WITH THE PV ARRAY CIRCUIT CONDUCTORS WHEN THEY LEAVE THE VICINITY OF THE PV ARRAY.'
cihy I
SCOPE:
9,315 KW DC ROOF MOUNT
SOLAR PV SYSTEM WITH
5. WHERE METALLIC CONDUIT CONTAINING DC CONDUCTORS IS USED INSIDE THE BUILDING, IT SHALL BE IDENTIFIED AS
"CAUTION:
..
SOLAR CIRCUIT" EVERY 10FT.
23 JINKO SOLAR: JKM405M-72HL-V 405
s
PV MONO MODULES WITH
6. HEIGHT OF THE AC DISCONNECT SHALL NOT EXCEED 6'-7" PER NEC CODE 240.24.
23 ENPHASE IQ8PLUS-72-2-US 290W
MICROINVERTERS EQUIPPED WITH
7. A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH CEC 690.47 AND 250.50 THROUGH 60 AND 250-166 SHALL BE
"
PROVIDED. PER NEC GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND BONDED TO THE SERVICE
RAPID SHUTDOWN
ENTRANCE. IF EXISTING SYSTEM lS INACCESSIBLE OR INADEQUATE A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED
L ke �"
AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT. GROUND ROD WITH ACORN CLAMP. GROUNDING ELECTRODE
w, L - `i
CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO LARGER THAN #6 AWG COPPER AND BONDED TO THE EXISTING
I Q S E P Fi C�TC�
AUTHORITIES
HAVING JURISDICTION:
GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM.
BUILDING:
CITY OF ZEPHYRHILLS
ZONING: CITY
OF ZEPHYRHILLS
8. PHOTOVOLTAIC MODULES ARE TO BE CONSIDERED NON-COMBUSTIBLE.
UTILITY: DUKE ENERGY
9. PHOTOVOLTAIC INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING. MECHANICAL, OR BUILDING ROOF VENTS.
10, ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE.
WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF THE ROOF SURFACE.
SHEETINDEX
11, ALL SINAGE TO BE PLACED IN ACCORDANCE WITH THE LOCAL BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV
RESISTANT. ALL PLAQUES AND SINAGE WILL BE INSTALLED AS REQUIRED BY THE NEC AND AHJ.
PV-1
COVER SHEET
PV-2
SITE PLAN
12. INVERTER(S) USED IN UNGROUNDED SYSTEM SHALL BE UL 1741 LISTED.
PV-3
ROOF PLAN & MODULES
PV-4
ELECTRICAL PLAN
13. THE INSTALLATION OF EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTION SHALL BE PERFORMED ONLY BY
QUALIFIED PERSONS [NEC 690.4(C)l
PV-5
STRUCTURAL DETAIL
PV-6
ELECTRICAL LINE DIAGRAM
14. ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED (OR BETTER), INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND
PV-7
WIRING CALCULATIONS
SWITCHES.
PV-8
PV-9
LABELS
PLACARD
15. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH NEC ARTICLE 250.
PV-10
MICRO INVERTER CHART
16. SYSTEM GROUNDING SHALL BE IN ACCORDANCE WITH NEC 690.41.
PV-11+
EQUIPMENT SPECIFICATIONS
17. PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION IN ACCORDANCE WITH
NEC690.12
�+
E EFE E CES
MC S
MODERN CONCEPTS SOLAR
201 N. FRANKLIN ST. SUITE 2200
TAMPA, FL 33602
REVISIONS
DESCRIPTION
DATE
REV
INITIAL DESIGN
10/03/2022
1558
STATE F Z-
ORM{
g'
Wyssting Consulting, PLL
76 N Mead brook Drive Alpine UT 84004
Florida License # RY34912
Date Signed 10/07/2022
PROJECT NAME & ADDRESS
N
Z LL
CO
�
0
W LL
_
L (D
—1 LU Z u
(r
o
00 CL
W
N
ATSIGNE
18. DISCONNECTING MEANS SHALL BE LOCATED IN A VISIBLE, READILY ACCESSIBLE LOCATION WITHIN THE PV SYSTEM
DRAWN BY
EQUIPMENT OR A MAXIMUM OF 10 FEET AWAY FROM THE SYSTEM [NEC 690.13(A)j
19. ALL WIRING METHODS SHALL BE IN ACCORDANCE WITH NEC 690.31
PROJECT TO COMPLY WITH THE FOLLOWING:
ESR
SHEET NAME
20, WORK CLEARANCES AROUND ELECTRICAL EQUIPMENT WILL BE MAINTAINED PER NEC 110.26(A)(1), 110.26(A)(2) AND 110.26(A)(3).
FLORIDA RESIDENTIAL CODE, 7TH EDITION 2020 (FRC)
COVER SHEET
FLORIDA PLUMBING CODE, 7TH EDITION 2020 (FPC)
21. ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED & IDENTIFIED IN ACCORDANCE WITH
FLORIDA BUILDING CODE, 7TH EDITION 2020 EDITION (FBC)
UL1703
FLORIDA MECHANICAL CODE, 7TH EDITION 2020 (FMC)
SHEET SIZE
2017 NATIONAL ELECTRICAL CODE
22, ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND ANCHOR CONDUIT RUNS AS REQUIRED PER NEC.
FLORIDA FIRE PREVENTION CODE, 7TH EDITION 2020
ANSI S
(FFPC)
11 " X 17"
SHEET NUMBER
PV-1
MODULE TYPE, DIMENSIONS & WEIGHT
NUMBER OF MODULES = 23 MODULES
MODULE TYPE = JINKO SOLAR: JKM405M-72HL-V 405W MONO MODULES
`-'... -.__-__..—_
(INSIDE HOUSE)
ROOF PLAN & MODULES
ROOF *1
PITCH co^
� ^zIM. 270'
ROOF DESCRIPTION
ROOF TYPE
ASPHALT SHINGLE
ROOF LAYER
1 LAYER
ROOF
#OF
MODULES
ROOF
PITCH
AZIMUTH
TRUSS
SIZE
TRUSS
SPACING
ARRAY AREA & ROOF AREA CALC'S
TOTAL PV ARRAY
TOTAL ROOF
ROOF
AREA
AREA
AREA COVERED BY
J,05W MONO MODULES WITH
�m|
PVPRODUCTION METER
COMBINER BOX
jACDj
AC DISCONNECT
�
SOLAR LOAD CENTER
UTILITY METER
�op
MAIN SERVICE PANEL
39A5"
�~
J|NK0SDLAR:
JKM405M-72HLV
4O5VVMODULES
-INVERTER
�s]
JUNCTION BOX
-
VENT, ATTIC FAN
-'
(ROOF OBSTRUCTION)
- ROOF ATTACHMENT
-- -- -TRUSS
--- -CONDU[T
MODERN CONCEPTS SOLAR
REVISIONS
DESCRIPTION
DATE
REV
INITIAL DESIGN
10/03/2022
cr
STAT OF
Date Signed 10/07/2022
PROJECT NAME & ADDRESS
I CO
am
4
mm
I
6*19 110014 a I to] 1, 'Wil WIN a I HT41 A I: I ilk I H W1 I I G: &Tj I In
FAY .121fA .1410M] jTjj:jjjL IS 11j:3 fl
Elm
mcmwmmm�s,
""LAR mc, S
T
MODERN CONCEPTS SOLAR
201 N. FRANKLIN ST. SUITE 2200
TAMPA , FL 33602
REVISIONS
DESCRIPTION
DATE
REV
INITIAL DESIGN
10/03/2022
kvif If I"!
10
J'-STAT
58
58
a— F
Wyssling Consulting® PLLC
76 N Meadewbrook Drive Alpine UT 84004
Florida License # RY34912
Date Signed 10/07/2022
PROJECT NAME &ADDRESS
CNI
Z Lr)
_j CO
Uj co
LI J U-
Z (D
:j LU z C6
< <
--1
< U) (D
or_ w o
N(D
0� I-
oo n
LIJ
N
DRAWN BY
ER
SHEET NAME
STRUCTURAL DETAIL
SHEET SIZE
ANSI B
11 " X 17"
SHEET NUMBER
Phi-5
DC SYSTEM SIZE: 23 X 405 = 9.315KW DC
AC SYSTEM SIZE: 23 X 290 = 6.670KW AC
(23) JINKO SOLAR: JKM405M-72HL-V 405W MONO MODULES
WITH (23) ENPHASE IQ8PLUS-72-2-US 290W MICROINVERTERS
EQUIPPED WITH RAPID SHUTDOWN
LOCATED UNDER EACH PANEL (240V)
(1) BRANCH CIRCUIT OF 12 MODULES AND
(1) BRANCH CIRCUIT OF 11 MODULES CONNECTED IN PARALLEL
JINKO SOLAR JKM405M 72HL-V
405W MODULES
BRANCH #1
1 2 3 0 0 0 11 [ 12
z
t
'p i i` ! 0 0 0 �Ft' ✓ I
BRANCH
TERMINATOR
(ET -TERM) ENPHASE IQ8PLUS-72-2-US 29OW
MICROINVERTERS EQUIPPED WITH
RAPID SHUTDOWN
LOCATED UNDER EACH PANEL (240V)
1.ELECTRICAL LINE
r DIAGRAM
m 11,4103
INTERCONNECTION NOTES:
I. INTERCONNECTION SIZING, LIMITATIONS AND COMPLIANCE
DETERMINED IN ACCORDANCE WITH [NEC 705.121, AND [NEC 690.591
2. GROUND FAULT PROTECTION IN ACCORDANCE WITH [NEC 215.91,
[NEC 230,951.
3. ALL EQUIPMENT TO BE RATED FOR BACKFEEDING,
4. PV BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE
BUSBAR RELATIVE TO THE MAIN BREAKER.
DISCONNECT NOTES:
1, DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN
THE SWITCH IS OPENED THE CONDUCTORS REMAINING LIVE ARE
CONNECTED TO THE TERMINALS MARKED "LINE SIDE" (TYPICALLY
THE UPPER TERMINALS)
2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY
PERSONNEL, BE LOCKABLE, AND BE A VISIBLE -BREAK SWITCH
3. DISCONNECT MEANS AND THEIR LOCATION SHALL BE IN
ACCORDANCE WITH [NEC 225.311 AND [NEC 225.321.
RACKING NOTE:
1. BOND EVERY RAIL WITH #6 BARE COPPER
ENPHASE IQ COMBINER
X-IQ-AM1-240-4/4C 120/240VAC,
1�, 3W 125A RATED BUS BAR,
NEMA 3R SOLAR LOADS ONLY
UL 1741 COMPLIANT
IQ ENVOY : PER
MANUFACTURER
SPECIFICATIONS, EITHER
I IQ ENVOY
10A OR 15A BREAKER IS
SUITABLE FOR USE
115A/2P
SOLADECK. '; 20A/2P
600V, NEMA 3R,
UL LISTED --- —ice
0-
=A/2P
LI
GROUNDING & GENERAL NOTES:
1. PV GROUNDING ELECTRODE SYSTEM NEEDS TO BE INSTALLED IN ACCORDANCE
WITH [NEC 690.431
2. PV INVERTER IS UNGROUNDED, TRANSFORMER -LESS TYPE.
3. DC GEC AND AC EGC TO REMAIN UNSPLICED, OR SPLICED TO EXISTING
ELECTRODE
4. ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT IS
FOUND TO BE INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINAL
INSPECTION.
5. SOLADECK QUANTITIES, AND PLACEMENT SUBJECT TO CHANGE IN THE
FIELD - SOLADECK DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE
TYPE TRANSITIONS,
6. AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER
AC DISCONNECTING MEANS IS LOCATED WITHIN 10' OF SERVICE DISCONNECT.
7. RACEWAYS AND CABLES EXPOSED TO SUNLIGHT ON ROOFTOPS SHOULD BE
INSTALLED MORE THAN 7/8" ABOVE THE ROOF USING CONDUIT SUPPORTS.
PV AC DISCONNECT
240V, 1�, 3W s
60A RATED
NEMA 3R I
i
LINE
0
LOAD4
VISIBLE, LOCKABLE,
LABELED AC DISCONNECT
LOCATED CLOSE PROXIMITY
TO UTILITY METER
QTY
CONDUCTOR INFORMATION
CONDUIT TYPE
CONDUIT
SIZE
(4)
#12AWG -
ENPHASE ENGAGE CABLE
(L1 & L2 NO NEUTRAL)
N/A
N/A
(1)
#10AWG -
CU,THWN-2 GND
(4)
#10AWG -
CU,THWN-2
(1)
#10AWG -
-- --
CU,THWN-2 GND
EMT OR LFMC IN ATTIC
3/4"
(2)
#8AWG -
CU,THWN-2
(1)
#8AWG
CU,THWN-2 N
EMT, LFMC OR PVC
3/4"
(1)
#10AWG -
--
CU,THWN-2 GND
-
CU,THWN-2
=(2_)�#8AWG
G
CU,THWN 2 N
EMT, LFMC OR PVC
3/4"
G -
CU,THWN-2 GND
. :," .AR AR
MODERN CONCEPTS SOLAR
201 N. FRANKLIN ST. SUITE 2200
TAMPA, FL 33602
REVISIONS
DESCRIPTION
DATE
REV
INITIAL DESIGN
10/03/2022
€d tE�Ft
Si
STATE F
RI
rr .,
#fflfttfE6tt40\
Wyssling Consuiting, PL.L
76 N Mead brook Drive Alpine UT 84004
Florida License # RY34912
Date Signed 10/07/2022
PROJECT NAME & ADDRESS
N
d'
_j Lo
00
C)
w U-
Lij Z Ct)
Q r J
Q u) ( _
LLI C\ ry
oo
CY) L1_)
N
TO UTILITY GRID
—L2
BI-DIRECTIONAL
UTILITY METER
120/240V, 1Q, 3-W
(E) MAIN SERVICE
DISCONNECT,
SQUARE D
240V,200A
(E) MAIN BREAKER TO
HOUSE 240V, 20OAI2P
L111-2 N.. G:.
(E) MAIN BREAKER,
I 240V. 200A/2P
j
(E) MAIN SERVICE
- # PANEL, CUTLER
-o HAMMER,
40A/2P € 200A RATED, 240V
i
tea----
h LOAD/LINE SIDE
INTERCONNECTION
AT MAIN PANEL/SUB
PANEL
PER ART. 705,12
BACK -FEED BREAKER
REF
m 2017 NEC 705.12(B)(2)(3)(b)
GEC
EXISTING GROUNDING
ELECTRODE SYSTEM TO EARTH N BY
W
REF. NEC 250.52, 250.53(A) DRAW
ESR
SHEET NAME
ELECTRICAL LINE DIAGRAM
SHEET SIZE
ANSI B
11" X 17"
SHEET NUMBER
PV-6
LABEL-1:
LABEL LOCATION:
AC DISCONNECT
ELECTRICAL SHOCK HAZARD
TERMINALS ON THE LINE AND LOAD SIDES MAY
BE ENERGIZED IN THE OPEN POSITION
LABEL- 2:
LABEL LOCATION:
AC DISCONNECT
COMBINER
MAIN SERVICE PANEL
SUBPANEL
MAIN SERVICE DISCONNECT
CODE REF: NEC 690.13(B)
LABEL- 3:
LABEL LOCATION:
UTILITY METER
MAIN SERVICE PANEL
SUBPANEL
CODE REF: NEC 705.12(C) & NEC 690.59
MVITOMMOV1111 R11101M
LABEL- 4:
LABEL LOCATION:
MAIN SERVICE PANEL
SUBPANEL
MAIN SERVICE DISCONNECT
COMBINER
CODE REF: NEC 110.27(C) & OSHA 1910.145 (0 (7)
LABEL-5:
LABEL LOCATION:
MAIN SERVICE PANEL (ONLY IF SOLAR IS BACK -FED)
SUBPANEL (ONLY IF SOLAR IS BACK -FED)
CODE REF: NEC 705.12(B)(3-4) & NEC 690.59
OUTPUTPOWER SOURCE
DO NOT
RELOCATE
OVERCURRENT
LABEL-6:
LABEL LOCATION:
MAIN SERVICE PANEL (ONLY IF SOLAR IS BACK -FED)
SUBPANEL (ONLY IF SOLAR IS BACK -FED)
CODE REF: NEC 705.12(B)(3)(2)
LABEL- 7:
1 ARFI 10(`AT[(1N
HL UI1'>1_u NIgt:u I
CODE REF: FFPC 11,12.1.1.1.1 & NEC 690.56(C)
LABEL- 8:
LABEL LOCATION:
AC DISCONNECT
CODE REF: NEC 690.56(C)(2)
LABEL- 10:
LABEL LOCATION:
MAIN SERVICE PANEL
SUBPANEL
AC DISCONNECT
CODE REF: NEC 690.54
LABEL- 11:
LABEL LOCATION:
MAIN SERVICE DISCONNECT (ONLY IF MAIN SERVICE DISCONNECT IS PRESENT)
CODE REF: NEC 690.13(B)
MODERN CONCEPTS SOLAR
201 N. FRANKLIN ST, SUITE 2200
TAMPA, FL 33602
REVISIONS
DESCRIPTION
DATE
REV
INITIAL DESIGN
10/03/2022
N\\
w
4
58
STATE
ORI®°
'��ttti�st�ttttt
Wyssting Consuiting, PLLC
76 N Meadowbrook Drive Alpine UT 84004
Florida license # RY14912
Date Signed 10/07/2022
PROJECT NAME & ADDRESS
N
z
Li co
U
w LL
_
Z
--� LLl z v6
Q d
� J
_
Q U) (D T_
V
CO 00
N
DRAWN BY
ESR
SHEET NAME
LABELS
SHEET SIZE
ANSI
1g1"X17"
SHEET NUMBER
PV-8
004'Y0,1 21Q,0M
j'K',141 01`1-72HL-V
c us
LISTED
ojinK0
MEY FEATURES
Diamond Cell Technology
IV clh-'i'g'm��
Y , I
HighVoltage
Higher Module Power
ShadeTollerance
„fe (, Use.., n a'7a'v,
f— ' , PID FREE
f Strength and Durability
P a� el o Omll f ;24, ck-, P�fl ��,ads
LINEAR !PERFORMANCE AA�ANTY
10 Year PTOdUCI Waffnrdy , 25 Year Linear P-mvefWaffanty
'q stan"jam" rxoi"Inal�e "1wra-mY
-'nk" ter
7 5,4A
JAI 7 616A
Vdu ge AAW",
As 3V 4'01%1�
5111 -5 2v
4,-a Vv
A,$ YNI
-'o,41 4qAAV
ing
20, Is%
2-0
Fil,
Max,
sx"'—'fit:ts 4 !Ax
rIT
Cf,4 Tenpa-:a1ge (NO-C"P,
d5i2C
NO C"If: M "V.ncj
MC.
S IAR
T
MODERN CONCEPTS SOLAR
201 N. FRANKLIN ST. SUITE 2200
TAMPA
, FL 33602
REVISIONS
DESCRIPTION
DATE
REV
INITIAL DESIGN
10/03/2022
PROJECT NAME & ADDRESS
c\1
z LO
-j CIO
LLJ x (Y)
cn
—i
V LL
Z (D
W z C6
ry
j
<
c/) (D
c\1
oo 12-
Cy') LLJ
N
DRAWN B
ESR
SHEET NAME
EQUIPMENT
SPECIFICATION
SHEET SIZE
ANSI B
11 " X 17"
SHEET NUMBER
Pal- 11
Our netivest 1Q8 Microinverters are the industry's first micrcgrhd-forming, Software -
defined microinverters with split -phase power conversion capability to convert DO
cover to AC paver efficiently. The brain of the semiconductor -based microinverter
is our proprietary application -specific integrated circuit (ASiC) which enables the
rniuroinver ter to operate in grief -tied cir -g, id modes. This chip is brain in advanced
55ntr, technology with high speed digital logic and foas super -fast response times
to changing loads and grid event& alleviating constraints on battery sizing for home
energy systems,
�fi,,.,
Fvrt of the rp a s e En lay `i kern 108 Series "Ca Wines MicinAnvertets vide'rre r wi N
Mcrat nver rtr.egratevet`theEnpha,-wBar tery, stancia€dsWith more knauode mflficn,auiniaia,Nei
Er phase n Gateway. and the E-,PH, we Aspatonrtmirig hcurs of roarer -or, teolng, enabling a^ d atry-
s.-d army; s softe w?, iemOstg Ivnitad wa, ranh, o4up to 25 gars.
C etvc4 e 1 ox>duosrt ic-my rid' ea lYf t.:Ind Serie<.. w8 Senrels P2icminv�,eers.;. e ,,L Listed as
picrran%v emusng*nice oad0-OCC-2cdapnt v Rapid Shut Down sgiipr.entandce,f..t^n+vath,.
cabin re'dh rlua-ir.-plart .4 connemos.�rar.r�rss eysa€,>ttcrs. ren instaffeda'al-I-Ircrrr4to
marzirfac^a:r€€ fin txr*[c.ns,
Easy to install
Lightweight and compact stith
plug-n-pray connectors
Poster Line Communication
(PLC) between components
Faster Installation with simple
two -wire cab, i g
High productivity and reliability
Produce power even when. the
grid is down`
More than one million cumulative
fours of testing
Class If rouble -insulated
enclosure
Optimized for the latest high-
powered PR` modules
Microgrie -for€ ing
Compiles with the latest
advanced grid support*,*.
Remote automatic updates for
the latest grid requirements
Corrflgurable to support a wide
range of grid profiles
Meets CA Rule 21(UL 1741-SA)
requirements
and + Microinverters
Commi—mry used m,xi e pairings' IN
MOW&'a -pa tttARry
60- i 1i12 haff-ioafi
235 440
SO-;eill/'[20 Hof-cMf €8-ce3s132 haff -xitil and L ocl:/144
ha€f-ce'sf
MPPT Voltage ear,.
27 _. 37
29_. B5
operatin ra, '..
25-48
25-53
Mln/ntax start acaitxge
1
30 r' 48
/ 58
Mm, 3np.ut'Dc vcrta'ge
V
50
60
May, DG c vent" `nod in, la
A
5
Ovrarvoftagecuss DCsrs,,rt
E!
DC post backfeed.rurrent
TA
w
PV arraycordouration
1A ungrcurrded air ay, No addit vinat DC
sole promatton reciuired€ AC side owection
retuiiov max 20A per bra„rn circuit
peak output. power
245
3Gip
Maxc,antti,a saUgPetpower
.�.
240
Nvinnah:(L L 1 voracge/range-
v
240 / 211- 264
Max ConftSiuous oupiw' c t>srero
-..
Li"t
1,21
Nviiiiina's*Itso ue'eroy
...a
60
Eatervied ferquoncy ran-ge
:._
50-6E
ACshisi cf cat braitcurierower
3 4 ifi
:'Ni:'RfB.
2
#fax unnspor20 A(L.-L) u=a-chccauit
yD
SS
Overvoi ate- view AC p a. t
AC ,port back€end current
3=0
PPosi-r factar sett s
to
Grid -tied power ta.ctor Tact stairs^ai
n 95 teamt, v S5 ae rv+
Peak eft Tito
%
97,5
91.6
CEC weighted effw,mrav,
a
97
97
Nhrs time power eursurmiLort
r,71
30
€§ntiprit umerature rare -40-6 "C (-2—F to v1401T
Relative hursx3rxy range 4 v to 100% (conderistrno
DC C a stew it t ixE „,4
Di,ensbnr (HoAkD) 212m; f8,3")z9.,x,302 ,m`12")
amfgdt 108kii( rdibs)
rvcding N.Wraii ^or; ec . - re) fans
Approved for wet toccisorts Yes
Pollution dead PD3
E, c,kxxire. Class 4 ;out;µ* -ins aieu., -orrostar mamlar r :rrnc,ic rice swfe
Er.vizon.ca.s -ry/'LNex€,i.isareneing P MATvpe6/=°a.rmbor
CA Rule 2 (UL 1741,-SA.). UL 662109 , UL 174111sPE1154Z r,CC Par, 1,5 Oaas B, ICE6-0003 Cess B, 2;APs WC SA- 2Z2 N00, 071,-01
!.`e€ti;tiz::ai>r;,s This product is UL Listed as, vV Rapid Shut Dakar Equiil new and cenforrna warn NEC 2014, NEC 2017, arid NEC 2020 slacmi
690,12 add C22.1-20118 Rule 64-215 Rapid Shutdown of PV eysten, s,for AC a id DC. err,: d<,;cwrs, when alien a, carding to
2022Enprois -E:�roy Al eighu^,es, eo Er h _x,...:e;...w..aa...`ogia,,C_fv" micro'rt._r ers.ardct ;r 'COW v ltzt u.is.ailedwi,r CSyVem �,nnoilws. n<sr cttu`a sins_€ucdc€ea.
�u:tte: are .a.e,^,ss.esc Enphose r ,; :ru. Data siibos�° tocnarice, rye r,s=.s"E.. ;74. (1)No enforced-DC+"GC a._. 5r_e'he %x patibirryr i...,.ote a2h»ems;./;na,...nC?'Asr c,ar�tirsrzd=.,aia <....,rtpa#:tr€;ii°
1QaP t.,. supports spk' phaxe. 24CN (2) Maximum continuous inpul DC cur r s iu.9A (3) havtoo! vc#ta ;e ra: tge car be cos <ded t000 d nornioa 1 reavi:r.eq
[CSSR-Da C4L2-w2-EN vS 2C22-03--17 .
by ,he utility, ,4. Urr.:_.a msr oar°{; ReTer 20 €ccaV ssGutramaittsioCure she numberal' macrcirrva. are per .sreneh in, tow area. i 5P-DS--00t32 f:i-ENa U5 202 :-u3-?i
MODERN CONCEPTS SOLAR
201 N. FRANKLIN ST.
SUITE 2200
TAMPA, FL 33602
REVISIONS
DESCRIPTION
DATE
REV
INITIAL DESIGN
10/03/2022
PROJECT NAME & ADDRESS
Z LO
_j CY)
M
co
0
W
_t
W
Z U)
®
J
'Q(D
rt/
e a e
LU
ry
a 7
V
C(14
LLl
N
DRAWN BY
ES
SHEET NAME
EQUIPMENT
SPECIFICATION
SHEET SIZE
ANSI
11" X 17"
SHEET NUMBER
PV-12
ff- I
n -Dn,. --a,,q e,
I
Q CC) I In e- 1 1,44 js 1 41 C,
X-IQ-AMl-240-4
X-IQ-AMl-240-4C
ubiru
smar,
ud","s fQ Gatewav �sirmunlC � 'I rm, an,, ,cw,, "A
iha�e kllobde 'n"I I
s "A i SP Inclu'det
COrn,0mier 4C
cs arc defiec, new
7
Rex bke
E�,hernet, or
rec- ade ava!lable ',-,.0 br;cke
des M ng ard
r-,r)un4UnQ,, bra,,kws
Tu d, nr,,ju n, td n g
S�jpv,,--s brjitcm—, back and sm�,P- condu�� ert-
p nc,
f ou, 2 p e- b ra p c h r, a i t s f -o r 2 J C
pug breakded-
8-A P v
Rel iable
Dt-�rable NRT'--e-ifec NS.&,,,A rype, 3R
limmted
p, 3 years Ian,-
�r,,:Jucled hol'h �-zxnb,ner KI-1 s
n.— ENPHASE
Enphase IQ Combiner 4/4C
NIODEL NUMBER
4 (X,Q, A,%,!�-24L 4� i�clxd ke p","e
0, -ruegral`e�,
.N C 12 -X- 2 5� m"o"er,
0� �c' (n, US,
wea fi-raclve�,a -,a,--- e-zi�ldio,-,alO�1,,,ul �,,ane,yarj c,
ACCESSORIES AND REPLACEMENT PARTS Inot injr _r a�
tPrIel-rl, M
CM0,4S smemblewtes
ODEM 4G ba-Lled LT;� Ce�' s, 4G based LTE-kil, cetiu�Ar n.,ex-lem -1- 5-
MLLMODF,al- 441, A,,-,rz5 feaf daul raz
B? eakc�s S-aoorl�Eaw, BR2��, ,R
5 IR K 11"js", 2
8Pk ',-�ja 2-249v' �Kcwl '�rsaker 21 fA, E, R2 I
-aw er �mt az -;e- t, ?11, ", ane
-ro s � -e c� r r 4
XA Plj,11,e,--z2lj 3 Ac,(eas-y kz x- 1- Cexlllb;r,,,ar -,'-C EPLU 0
x,- V!
ELECTRICAL SPEC=FiCATIONS
Eaton OF �w�Fes bu-,�-,ar w,,ng
gr�,mh crrwts (sr,!,r of
Enwav
A
64 A
A
Up, 0 k)ur 2, po�e Eaan , R Di�tvb,,P�d )Wy �VDt mdujee, 3
8'A ,f
�OA o� I SP ratmyg G� � S�cme E at-= �,-muaee
'e, -0,
as.im, , ut,on munitcw-.V -T 200 SPU 1) A ew, of 20,0 A sp� c�c�e
MECHANICAL DATA
40-Clo -46�`
-4�
, ,nAos -A cl,"Adco" NR- N0VA typ�, 'IR pcyca�bon-ate corwr-c',on,
MC.
MODERN CONCEPTS SOLAR
201 N. FRANKLIN ST. SUITE 2200
TAMPA
, FL 33602
REVISIONS
DESCRIPTION
DATE
REV
INITIAL DESIGN
10/03/2022
PROJECT NAME &ADDRESS
z Lp
I c1l)
c1l
LLJ Of )
Go
-j
Lij LL
z (D
z C6
<
<
cr-
—j
<
U) (D
w 0
04
(D
0�f r--
oo
LIJ
N
DRAWN BY
ESR
SHEET NAME
EQUIPMENT
SPECIFICATION
SHEET SIZE
ANSI ELIJ
11 " X 17"
SHEET NUMBER
PV-1 3
CrosslRall System
12 13
10 14
..................
rq,rqS� v 4v�
C.'rosslRall LILI-X
Mechanical Proper -Lies
Materiall
Yield Strength
Finish
Section Properties
34 8 ks„ f"4`40 MPa)
Mi!! or Arwodlze,�
I Srijcwal values and, Span c,"'lar's deterr-ninied irl accordarce vvith Alumni,um Design Manua; and ASC-fl: 7-16
1 U�,21-,031-i,--Ii�O'S-ister,�tf�)rFfrear�,dBorid�ng
MC
S,
LAR
MODERN CONCEPTS SOLAR
201 N. FRANKLIN ST. SUITE 2200
TAMPA,
FL 33602
REVISIONS
DESCRIPTION
DATE
REV
INITIAL DESIGN
10/03/2022
PROJECT NAME &ADDRESS
CV
Z Lo
_j ('r)
co
w
co
G�
co
c)
w LL _j
z
(D
w
z U�
<
0
<
n-
j
<
—
U)
(D
cr
W
c:)
c\1 >
r-- =
00 0-
CIO LLJ
N
DRAWN BY
ESR
SHEET NAME
EQUIPMENT
SPECIFICATION
SHEET SIZE
ANSI B
11" X 17"
SHEET NUMBER
PV-1 4
H
Splice Foot XL
Patent Pending
We support PV systems
Formerly Everest Solar Systems 0�
MC
MODERN CONCEPTS SOLAR
201 N. FRANKLIN ST, SUITE 2200
TAMPA, FL 33602
REVISIONS
DESCRIPTION
DATE
REV
INITIAL DESIGN
10103/2022
PROJECT NAME &ADDRESS
C14
Z Lf)
_j (y)
Uj ry, cy)
—j
LLJ Li-
z (D
w z C6
< I
U) (D
W C) ry
CN >-
I-- T—
co n
CO LLJ
N
DRAWN BY _____
IESR
SHEET NAME
EQUIPMENT
SPECIFICATION
SHEET SIZE
ANSI B
11" X 17"
SHEET NUMBER
Pie-1 5
ran
Construction
* Stamped Seamless
#: Gauge v
Powder
eii
* Flashes into the roof deck
urfaces
* 5 Centering dimples for entry/exit
fittings or conduit
* 2 Position Ground lug installed
* Mounting Hardware Included
"Fuse holders and terminal blocks
added in the Send mast be UI. listed or
recognized and Treat 600 VD(-- 30 AMP
11 LC for kise holders, 600V 50 AMP
00C for rail Taunted terminal vl s
and 600 A 175 AMP 90C for Power
Dr t lbut on= Stacks, Use f--opt r 4" ge
conductors,
ShcaDe k Model SO 0783
Available IVI
Model SID 0783 - (3w fixed Din Pain
Model SD 0788 - ( " slatted Din Rail)
SoIaDeck UL 1741 Combiner/Enclosures
Models SD 0,783- 1 and SD 0 7 8641 are labeled and ETL listed UL STD 1741
according to the UL STD 1741 for photovoltaic combiner enclosures -
Max Fated - 60OVDC, 12 AMPS
Model SD 783m41 3" Fixed Dirt Pail fastened using Norlock Systern
*Typical System Configuration
4_ Din Pail Mounted Fuse Holders 60OVDC 30 AMP
1. Power Distribution Black 600VDC 175A P
1-- Bus Bar Wth UL lug
Model SD 8 1 " Slotted Dine Fail fastened usine steel Studs
"Typical System Configuration
4- Din Fail Mounted Fuse Holders 60OVDC 30 AMP
4- Din Pali Mounted Terminal Blocks
Bus Bars with UL lug
Cower is trimmed to allow Model SO 07 3-41, wrred with Model SO 07 S-4€ , vnred with
condo t Or fi ngs loses Dt„ Rail mounted fuse holders, Dart Rail mounted fuse hefders,
center dimpled for fitting bus bar and power distnbution terminal blocks and bus,I
Inca to as. block,
RSTC Enterprises, Inc - 2219 Heirnst ad Road . Eau Chore, W1 54703
Forproduct information call (866) 67-7782
MODERN CONCEPTS SOLAR
201 N. FRANKLIN ST.
SUITE 2200
TAMPA, FL 33602
REVISIONS
DESCRIPTION
DATE
REV
INITIAL DESIGN
10/03/2022
PROJECT NAME & ADDRESS
cv
Z
Lij
Ify
m
U
LU LL
Z
—j
Z U
<
J
Q
_
C/)
CD _
L1J
o
n
op
CY3 W
N
DRAWN BY
ESR
SHEET NAME
EQUIPMENT
SPECIFICATION
SHEET SIZE
ANSI S
11" X 17"
SHEET NUMBER
PV-16