Loading...
HomeMy WebLinkAbout22-5238City of Zephyrhills 5335 Eighth Street Zephyrhills, FIL 33542 ELCMISC-005238-2022 Phone: (813) 780-0020 Fax: (813) 780-0021 Issue Date: 11/17/2022 REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. I I I I I 'I I �JI I I I I III I I I I I l J! lll!!Illll!!Illl Jill I 1 1! Ill!l Ii Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. --- 'coNTRAcToR SIGNATURE PEPT OFFICE0 ITHOUT APPROVED INSPECTION WEST B.,,,xi,;r ENER6,,'-VT' 1 111111111111111111;1111 11111 HBO RUMMIUM114M I Please allow ONLY the person(s) listed below to sign. This letter supersedes all others. Greg Ennist Pornchai Souvannasy Contractor's Signature: Contractor's Printed Name: SkAr\e- STATE OF FLORIDA The foregoing instrument was acknowledged before me this —J -rl, 1(51L day of 20,a.�_ by -- who is persona known to me MMEM 111 1(0s 0/0— 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received 10/17/22 Phone Contact for pennittinit 7 7 — 6744 sssssssass Owner's Name James Converse Owner Phone Number 8133958828 Owner's Address [6:,5:5::1::N:0:rth�1akeDr Z�ePhyrh1lI5:F:L:3::3:jj2:Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS LOT # SUBDIVISION PARCEL (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTRE] ADD/ALT SIGN DEMOLISH INSTALL REPAIR PROPOSED USE SFR COMM OTHER Si7 Br TYPE OF CONSTRUCTION BLOCK FRAME STEEL RO=OF :M�O:U�NTED S�OLAR P�V���� DESCRIPTION OF WORK E= BUILDING SIZE SO FOOTAGE HEIGHT Xkkxkxxkxx [:EBUILDING VALUATION OF TOTAL CONSTRUCTION 33214 [:I:]ELECTRICAL E= AMP SERVICE PROGRESS ENERGY = W.R.E.C. =PLUMBING M7_1 =MECHANICAL VALUATION OF MECHANICAL INSTALLATION =GAS ROOFING = SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY West Bay Energy LLC FEECVR�R�N��� SIGNATURE REGISTERED Y/N Y/N Address 6260 39th St N Ste I Pinellas Park FL 33781 License # ELECTRICIAN COMPANY West Bay Energy LLC SIGNATURE REGISTERED CURREN Address License # 13010037 PLUMBER COMPANY E;�� SIGNATURE REGISTERED . C.RRFN_� Address License # MECHANICAL COMPANY E SIGNATURE = REGISTERED �Y / N FEE CLJRR�.NY / N�� Address License # OTHER COMPANY SIGNATURE = REGISTERED Eun... Address License RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans-, (1) set of Energy Forms; R-O-W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdMsions/large projects COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms, R-O-W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans, *-PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign back of application, notarized It over $2500, a Notice of Commencement Is required. (A/C upgrades over $7500) — Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Ramble If shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage) Driveways -Not over Counter if on public roadways.,needs ROW 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible, If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting, It is further understood that Transportation impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release, If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTIONLIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500,00 or more, I certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs, If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the 'owner" prior to commencement. CONTRACTOR'SIOWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to, Department of Environmental Protection -Cypress Bayheads, Welland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment, Southwest Florida Water Management District -Wells, Cypress Bayheads, Welland Areas, Altering Watercourses. - Army Corps of Engineers -Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency -Asbestos abatement. - Federal Aviation Authority -Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida, - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall, - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes, Every permit Issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension, If work ceases for ninety (90) consecutive days, the job is considered abandoned. OWNER OR AGENT I --------- CONTRACTOR �11 �t��and awe lcrop )b met iSrbscdbad d sworn to or affirmed) m this wc% ;0h.v. _In b by Who is/are _gro1na&11vI,1*wkn to m a or has/have produced Who is/are pers nally has/have produced _ Lnwn to me or he as identification. _ as identification. Cj,'CA SV'k t telAWtary Public �.Notary Public Commission No, Commission No. 'Ram. of Notary typed, printed _o, stamped game of Notary typed, printed orstamped 14, Ili Cii COMM 2925 Bonde Thru AWn NM21y OF ""film DocuSign Envelope ID: 402C8799-F8A5-4E5F-816C-9423E6177174 WEST BAY ENERGY 6260 39TH STREETN SUITE I PINELLAS PARK, FI, 33781 EC 13010037 DATE: 10/3/2022 CUSTOMER NAME (HEREINAFTER, THE "CUSTOMER") James Converse ADDRESS: 6551 Northlake Drive CITY, STATE, ZIP: zephyrhills, FL 33542 MOBILE PHONE NUMBER- 813-395-8828 EMAIL- jmc57Caatt.net SYSTEM INFO: SYSTEM SIZE: 11. 7 KW CONTRACT PRICE- $32,214 PANEL: 30 Mitrex 390-AlF TOTALITC: $9,664 COMMENTS: Price includes all parts, permit, and labor. Lash Sale 30% down will be sent 10/3/22 by bank check. PRICE AF-I'ER ITC: $22,549 CASH JOB TERMS: 30% DOWN DUE AT SIGNING REMAINING 70% DUE ON DAY OF INSTALLATION REQUIRED AGREEMENTS: THE CUSTOMER DECLINED TO PROVIDE WBE WITH 4 THE CUSTOMER HAS PROVIDED UTILITY COMPANY POWER BILLS. TTIE ABOVE SYSTEM SIZE WBE WITH A MINIMUM OF 4 WAS REQUESTED BY THE CUSTOMER, ADDITIONALLY,THE OR UTILITY COMPANY POWER BILLS CUSTOMER AGREES THERE HAVE BEEN NO GUARANTEES AS TO ENSURE THE PROPER ENERGY TO HOW MUCH OF THE POWER BILL WILL BE REDUCED AND,' CONSUMPTION CALCULATION. OR ELIMINATED. 1 AGREE WITH'ITIE, ABOVE PRODUCTION AND CONSUMPTION SELECTION r-' BATTERY: IF I AM PURCHASING AN ENPIIASE BATTERY SYSTEM, I HAVE READ AND SIGNED THE SEPARATE BATTERY FORM 1IOA: I HAVE READ AND SIGNER THE SE"PARATE, I IDA AGREEMENT FORM TIER 2 INSURANCE: I HAVE READ AND SIGNED THE, SEPARATETIER 2 INSURANCE FORM -N WBE APP: I AGREE TO DOWNLOAD THE, WBE APP, AVAILABLE ON APPLE AND ANDROID, TO RECEIVE COMMIJ, ICATIOIS ABOUT MY PROJECT FROM THE WBE STAFF. SHADING MAINTFNANCE: I HAVE READ AND SIGNED THE SEPARATE SHADING MAINTENANCE FORM. CUSTOMER ACKNOWLEDGES SHADING WILL NEGATIVELY IMPACT SOLAR PRODUCTION. 1. ___4_,y,_COOP UTILITY POWER COMPANIES: CO-OP UTILITY POWER COMPANIES (INCLUDING BUT NOT LIMITED TO: PEACE RIVER, WlTiNLOCOCHE, LAKELANDY ]'HE CUSTOMER UNDERSTANDS THE NET METER POLICY OF THEIR UTILITY CO-OP INCLUDING THE 13UY BACK RATES. 2. J,CUSTOMFR REPRESENTATION OF AUTHORITY: IF CUSTOMER IS FINANCING THIS TRANSACTION, CUSTOMER EXPRESSLY WARRANTS, PROMISES AND REPRESENTSFHATCUSTOMLR IS THE OWNER OFTHE SUBJECT PROPERTY TO WHICH THIS SALES CONTRACT PERTAINS AND HAS TOTAL, COMPLETE AND FXCLUSIVF AUTHORITY TO ENTER INTO THIS LEGAL BINDING SALES CONTRACT. 3. —1- —CONTRACTOR REPRESENTATIONS: CONTRACTOR REPRESENTS THAT IT WILL PERFORM ALL WORK IN A WORKMANSHIP -LIKE'. MANNER AND IN COMPLIANCE WITH ALL BUILDING CODES AND APPLICABLE LAWS. 4. CONTRACTOR INSURANCE: CONTRACTOR REPRESE-NNTS THAT IT IS ADEQUATELY INSURED. 5. ___j.&_COMMENCEMETNTT OF WORK: CUSTOMER AND CONTRACTOR AGREE THAT THE APPROXIMATE DATE FOR COMMENCING PERFORMANCE OF THE ABOVE DESCRIBED WORK WILL BE SCHEDULED WITHIN30 DAYS OF ISSUANCE OF BLnDTNG PERMIT, ("START DATE") 6. ___FURTHER ASSURANCES: EACH PARTY TO THIS SALES CONTRACT SHALL EXECUTE AND DELIVER ANY ADDITIONAL DOCUMENTS AND INSTRUMENTS AND PERFORM ANY ADDITIONAL ACTS THAT MAY BE NECESSARY OR APPROPRIATE TO EFFECTUATE AND PERFORM T14E PROVISIONS OF THIS SALES CONTRACT AND THE TRANSACTIONS CONTEMPLATED HEREIN 7. _____k,&_LIQUU)ATFD DAMAGES: T14F PARTIES HEREBY AGREE THAT, IN THE EVENT CUSTOMER RESCINDS OR CANCELS THIS SALES CONTRACT AFTER THE EXPIRATION OF THREE BUSINESS DAYS, WITH OR WITHOUT CAUSE, CONTRACTOR SHALL BE ENTITLED TO LIQUIDATED DAMAGES IN AN AMOUNT OF $1,500.00 PLUS COSTS OF ALL INCURRED COSTS AND EXPENSES TO INCLUDE BUT NOT BE LIMITED TO PERMITS, SURVEYS, THIRD PARTY INSPECTIONS, PLANS, BLUEPRINTS, NON-REFUNDABLE PRODUCT ORDERS, SPECIALTY ORDERS AND RECORDING FEES. .1 S. _____ARBITRATION AND CHOICE OF LAW: AT THE. EXCLUSIVE ELECTION OF THE CONTRACTOR, ALL DISPUTES ARISING OUT OF OR RELATED TO THIS SALES CONTRACT, OR TOTHE INTERPRETATION, PERFORMANCE, BREACH OR TERMINATION THEREOF MAY BE RESOLVED BYBINDING ARBITRATION' ADMINISTERED BY THE AMERICAN ARBITRATION ASSOCIATION (THE "AAA') UNDER ITS COMMERCIAL ARBITRATION RULES, WITH THE APPLICATION OF ITS EXPEDITED PROCEDURES, BEFORE A SINGLE ARBITRATOR, SUCH ARBITRATION SHALL TAKE PLACE AT THE OFFICES OF THE AAA IN MIAMI, FLORIDA OR SUCH OTHER LOCATION AS THE PARTIES TO SUCH ARBITRATION MAY AGREE. THE PARTIES EXPRESSLY AGREE THAT NOTHING IN THIS SALES CONTRACT WILL PREVENT THE PARTIES FROM APPLYING TO A COURT THAT WOULD OTHERWISE HAVE JURISDICTION FOR INJUNCTIVE OR OTHER EQUITABLE RELIEF, AFTER THE ARBITRATOR IS SELECTED, HE!SHE WILL HAVE SOLE JURISDICTION TO HEAR SUCH APPLICATIONS, EXCEPT THAT THE PARTIES AGREE THAT ANY RELIEF ORDERED BY THE ARBITRATOR MAY BE IMMEDIATELY AND SPECIFICALLY ENFORCED BY A COURT OTHERWISE HAVING JURISDICTION OVER THE PARTIES, THE ARBITRATOR SHALL APPLY THE SAME SUBSTANTIVE LAW, WITH THE SAME STATUTES OF LIMITATIONS AND SAME REMEDIES THAT WOULD APPLY IF THE CLAIMS WERE BROUGHT IN A COURT OF LAW, THE DECISION OF THE ARBITRATOR SHALL BE FINAL AND BINDING ON THE PARTIES, THE DECISION OF THE ARBITRATOR SHALL BE CONCLUSIVE AND MAY BE ENFORCED IN A COURT OF COMPETENT JURISDICTION, SUBJECT ONLY TO APPEAL TO AN APPELLATE ARBITRATOR IN THE EVENT OF THE ARBITRATOR'S MISAPPLICATION OF THE LAW, NO EVIDENCE TO SUPPORT THE AWARD, OR SUCH OTHER GROUNDS FOR APPEAL OF ARBITRATION AWARDS THAT EXIST BY STATUTE. THIS ARBITRATION PROVISION SHALL SURVIVE CLOSING, BREACH OR TERMINATION OF THIS SALES CONTRACT. THE PARTIES SPECIFICALLY AGREE THAT THE FEDERAL ARBITRATION ACT OF 1925 PREEMPTS ANY AND ALI, STATE LAWS, INCLUDING, WITHOUT LIMITATION, THOSE REGARDING THE PROHIBITION BY CONTRACT OF THE DISALLOWANCE OF CLASS -WIDE ARBITRATION. THIS SALES CONTRACT SHALL Bill; GOVERNED BY THE LAWS OF THE STATE OF FLORIDA AND VENUE, IF ANY. SHALL LIE IN PINELLAS COUNTY, FLORIDA. 9. _JA_CUSTONIER WARRANTIES AND REPRESENTATIONS: CUSTOMER EXPRESSLY WARRANTS, PROMISES AND REPRESENTS THAT HE/SHE HAS VOLUNTARILY SIGNED THIS SALES CONTRACT AND UNDERSTANDS THAT HE/SHE IS HEREBY AUTHORIZING CONTRACTOR TO COMPLETE THE WORK PERFORMED UNDER THIS SALES CONTRACT IN CONSIDERATION FOR PAYMENT OF THE CONTRACT PRICE. 10. �J_COMPLETF SALES CONTRACT: CUSTOMER AGREES THAT CONTRACTOR NEITHER MADE NOR HAS CUSTOMER RELIED UPON ANY PROMISES, REPRESENTATIONS OR WARRANTIES IN CONNECTION WITH THIS SALES CONTRACT WHICH ARE NOT EXPRESSLY SET FORTH MINING DocuSign Envelope ID: 402CB799-FBA5-4E5F-816C-9423E6177174 11. (_�` _jI.CONSTRUCTION: THE PARTIES ARE SOPHISTICATED AND WERE OR COULD HAVE BEEN REPRESENTED BY COUNSEL DURING THE NEGOTIATION OF THIS SALES CONTRACT. CUSTOMER AND CONTRACTOR AGREE AND ACKNOWLEDGE THAT ,THE PARTIES JOINTLY NEGOTIATED THIS SALES CONTRACT AND THE PARTY WHO DRAFTED ANY PROVISION OF THIS SALES CONTRACT SHALL NOT SUFFER ANY ADVERSE PRESUMPTIONS AS A RESULT OFTHAT FACT. 12. __jj_PARTIES BOUND: THIS SALES CONTRACT SHALL BE BINDING UPON PARTIES AND THEIR RESPECTIVE SUCCESSORS, ASSIGNS, HEIRS, DEVISEES, LEGAL REPRESENTATIVES, EXECUTORS AND ADMINISTRATORS. ' 13. SOLE REMEDIES: CUSTOMER AGREESTHAT HIS/HER SOLE FOR ANY ALLEGED AND EXCLUSIVE REMEDY BREACH OF THIS SALES CON TRACT13Y CONTRACTOR AS LIMITED TO (A) THE RETURN OF THE NON -CONFORMING GOODS AND PARTS AND REPAYMENT` OF THE PURCHASE PRICE, OR (B) REPAIR AND REPLACEMENT OF NON —CONFORMING GOODS OR PARTS, CUSTOMER ALSO AGREES THAT IS AFOREMENTIONED SOLE AND EXCLUSIVE REMEDIES ARE FAIR AND REASONABLE IN LIGHT OF THE CIRCUMSTANCES, 14. LAWS: ONE OF THE MANY BENEFITS OF SOLAR ENERGY IS ENTITLEMENT TO TAX BENEFITS AND INCENTIVES. TAX LAWS AND REGULATIONS CHANGE FREQUENTLY, AND THEIR APPLICATION CAN VARY WIDELY BASED ON THE SPECIFIC FACTS AND CIRCUMSTANCES INVOLVED, YOU ARE RESPONSIBLE FOR CONSULTING WITH YOUR OWN PROFESSIONAL TAX ADVISORS CONCERNING ANY SPECIFIC TAX CIRCUMSTANCES FOR YOU AND/OR YOUR HOUSEHOLD. CUSTOMER ACKNOWLEDGES THAT CONTRACTOR IS NOT A TAX PROFESSIONAL, HAS NOT RENDERED ANY SPECIFIC REPRESENTATIONS REGARDING ANY TAX REFUNDS. DEDUCTIONS OR INCENTIVES, NOR HAS CUSTOMER RELIED ON, ANY STATEMENTS OR ADVICE FROM CONTRACTOR REGARDING TAX LAWS, REBATES OR INCENTIVES. CONTRACTOR, ITS AGENTS AND REPRESENTATIVES DISCLAIM ANY AND ALL RESPONSIBILITY FORTHE ACCURACY AND ADEQUACY OF ANY POSITIONS TAKEN BY CUSTOMER WITH REGARDING TO ANY AND ALL FAX RETU'RNS OR OTHER DEALINGS WITHTHE INTERNAL REVENUE SERVICE ("IRS") 15. TAX CREDIT: WEST BAY ENERGY, IT'S REPRESENTATIVES OR AGENTS, MAKE NO GUARANTEES, REPRESENTATIONS REGARDING CUSTOMER'S ELIGIBILITY OR ENTITLEMENT TO ANY TAX CREDIT, FURTHER, CONTRACTOR ASSUMES NO LIABILITY SHOULD CUSTOMER NOT RECEIVE A TAX CREDIT AS EACH INDIVIDUAL HAS A DISTINCT TAX CIRCUMSTANCE, TAX CREDITS ARE BASED UPON INDIVIDUALIZED FACTORS AND THE CUSTOMER IS ENCOURAGED TO SEEK INDEPENDENT TAX ADVICE. 16. _—LL--CONSTRUCTION DEFECT: ANY CLAIMS FOR CONSTRUCTION DEFECTS ARE SUBJECT TO THE NOTICE AND CURE PROVISIONS OF CHAPTER 558. FLORIDA STATUTES WHICH PROVIDES, AMONG OTHER THINGS, THAT CUSTOMER PROVIDE CONTRACTOR WITH WRITTEN DETAILED NOTICE OF DEFECT GRANT] , NG CONTRACTOR AN OPPORTUNITY TO CURE, 17. 1 ( REMOVAL OF PANELS: SHOHL D CLIENT LISTED HEREIN NEED A NEW ROOF OR TO UNMOUNT OR REMOUNT PANELS�FOR A REASON DEEMED NECESSARY, WEST BAY ENERGY WILL UNMOUNIT AND REMOUNT PANELS FOR A LABOR ONLY CHARGE OF S 100 PER PANEL. PRODUCTION GUARANTEE: THE FOLLOW PROJECTIONS ARE BASED ON THE. CURRENT POWER CONSUMPTION PROVIDED BY THE CUSTOMER THROUGH CURRENT POWER BILLS AND ARE, PROJECTING THAT THE CUSTOMER DOES NOT INCRFASE POWER CONSUMPTION AFTER THE INSTALLATION oF'THE SOLAR SYSTEM, 11.7 KW SYSTEM SIZE: DESIGNED FOR OPTIMAL PERFORMANCE 14,680 KWH PROJECTED ENERGY REQUIRED BASED ON INPUT FROM CUSTOMER AND THE POWER BILLS PROVIDED BY THE CUSTOMER.THIS IS THE AMOUNT OF ENERGY THE CUSTOMER IS PROJECTED TO USE. 15 = 807 KWH PROJECTED ENERGY PRODUCTION OF THE SOLAR SYSTEM 100 % PROJECTED ENERGY OFFSET, BASED UPON INPUT FROM THE CUSTOMER AND THE POWER BILLS THE CUSTOMER PROVIDED TO WEST BAY ENERGY. IF ON AN ANNUAL BASIS, THE SOLAR SYSTEM DOES NOT PRODUCE THE PROJECTED ENERGY. WEST BAY ENERGY WILL PROVIDE A REMEDY SUCH AS ADDING ADDITIONAL SOLAR PANELS FOR NO COST OR PAY A PORTION OF THE POWER BILL. DocuSign Envelope ID: 402C8799-FBA5-4E5F-816C-9423E6177174 19. WARRANTIES: 25 VEAR LIMITED ROOFING PENETRATION WARRANTY: WEST BAY ENERGY WARRANTS YOUR ROOF AGAINST DAMAGE AND WATER INFILTRATION AT EACH ROOFING PENETRATION MADE BY WEST BAY ENERGY IN CONNECTION WITH THE INSTALLATION OF THE" SYSTEM AND THE IMMEDIATE SURROUNDING AREA OF EACH SUCH PENETRATION (COLLECTIVELY, THE "COVERED ROOF AREAS"). WEST BAY ENERGY WILL REPAIR DAMAGE TO YOUR ROOF AND REPAIR OR COMPENSATE YOU FOR ACTUAL PHYSICAL DAMAGE, TO YOUR PROPERTY RE'suLTING FROM ANY WATER INFILTRATION IN THE EVENT OF FAILURE OR DEFECTS IN THE COVERED ROOF AREAS. THIS 25 -YEAR LIMITED ROOFING PENETRATION WARRANTY WILL EXTEND FOR A PERIOD OF TWENTY FIVE (25) YEARS FROM THE DATE, INSTALLATION OF THE SYSTEM IS COMPLETED BY WEST BAY ENERGY ; PROVIDED, HOWEVER, IN THE EVENT THE ROOF IS MORE THAN -TWENTY (20) YEARS 01-D (OR JUDGED TO BE IN POOR[UNACCEPTABLE CONDITION BY WEST BAY ENERGY) AT COMMENCEMENT OF THE SYSTEM INSTALLATION, THIS LIMITED ROOFING PENETRATION WARRANTY WILL BE LIMITED TO A PERIOD OF FIVE (5) YEARS FROM THE DATE INSTALLATION OF THE SYSTEM IS COMPLETED BY WEST BAY ENERGY UNLESS YOU PROVIDE WEST BAY ENERGY WITH A REPORT FROM A STATE LICENSED ROOFING CONTRACTOR THAT PROVES TO WEST BAY ENERGYS SATISFACTION THAT THE ROOF IS IN AN, ACCEPTABLE CONDITION BASED UPON AN INSPECTION CONDUCTED NO MORE THAN NINETY (90) DAYS BEFORE COMMENCEMENT OF THE SYSTEM INSTALLATION, WEST BAY ENERGY ASSUMES NO LIABILITY FOR OR RESPONSIBILITY IN RELATION TO ANY EXISTING ROOFING WARRANTIES DURING OR AFTER THE INSTALLATION OF THE SYSTEM EXCEPT TO THE EXTENT OF THE 25- YEAR LIMITED ROOFING PENETRATION WARRANTY. RIM WEST BAY ENERGY WILL PROVIDE, AT NO COST TO CUSTOMER, LABOR AND SERVICES SUPPORT IN CONNECTION WITHTHE REPAIR OR REPLACEMENT OF ANY MATERIAL, EQUIPMENT, PRODUCT, OR COMPONENT INCORPORATED INTO AND MADE, A PART OF THE SYSTEM (EACH A"SYSTEM PRODUCT" AND COLLECTIVELY TIIE­sysTEm PRODUCTS") THAT IS COVERED UNDER A WARRANTY PROVIDED BY ANY SUPPLIER, MANUFACTURER, SUBCONTRACTOR, VENDOR, OR OTHER APPLICABLE THIRD PARTY (EACH A "SUPPLIER" AND COLLECTIVELY THE "SUPPLIERS") OF SUC14 SYSTEM PRODUCJ-,LHjS 25-YEAR LimiFED LABOR AND SERVICE WARRANTY WILL EXTEND FOR A PERIOD OF TWENTY FIVE (25) YEARS FROM THE DATE INSTALLATION 01, THE SYSTEM IS COMPLETED BY WEST BAY ENERGY. WHO WARRANTS THE MATERIALS AND PRODUCTS CONTAINED IN THE SYSTEM? ALL WARRANTIES ON PRODUCTS AND MATERIALS ARE WARRANTIES OF THE MANUFACTURER. WEST BAY ENERGY, IS AN INSTALLER CONTRACTOR BUT AS A CUSTOMER COURTESY, WILL REQUEST AND PROVIDE CUSTOMER WITH THE STANDARD WARRANTIES AND GUARANTEES (IF ANY AND WHERE APPLICABLE) PROVIDED BY SUPPLIERS (INCLUDING 'THE MANUFACTURERS) OF THE SYSTEM PRODUCTS ("SYSTEM PRODUCT WARRANTIES"). TO THE EXTENT PERMITTED, WEST BAY ENERGY WILL ASSIGN THE SYSTEM PRODUCT WARRANTIES DIRECTLY ToTHE CUSTOMER. WEST BAY ENERGY WILL REASONABLY ASSIST THE CUSTOMER WITH OBTAINING WARRANTY ASSISTANCE TO THE EXTENT ANY SYSTEM PRODUCTS ARE DEFECTIVE OR DAMAGED. 20. __44__FLORIDA HOMEOWNERS'CONSTRUCTION RECOVERY FUND: PAYMENT MAY BE AVAILABLE FROM THE FLORIDA IJOMEOWNERS' CONSTRL vLION RECOVERY FUND IF YOU LOSE MONEY ON A PROJECT PERFORMED UNDER CONTRACT, WHERE THE LOSS RESULTS FROM SPECIFIED VIOLATIONS OF FLORIDA LAW BY A LICENSED CONTRACTOR, FOR INFORMATIOINI ABOUT THE RECOVERY FUND AND FRANC, A CLAIM, CONTACT THE FLORIDA CONSTRUCTION INDUSTRY LICENSING BOARD AT THE FOLLOWING TELEPHONE NUMBER AND ADDRESS: FLORIDA HOMEOWNERS' CONSTRUCTION RECOVERY FUND 1940 NORTH MONROE STREET TALLAHASSEE, FL 32399-2215 (850-921-6593) 21. NOTICE OF CANCELLATION TERMS & CONDITIONS, YOU MAY CANCEL T141S TRANSACTION WITHOUT ANY PENALTY OR OBLIGATION WITHIN THREE (3) BUSINESS DAYS FROM THE DATE HANDWRITTEN HEREIN, IF YOU CANCEL, YOU MUST MAKE AVAILABLE TO THE SELLER AT YOUR RESIDE IN SUBSTANTIALLY AS GOOD CONDrnO\AS WHEN RECEIVED, ANY GOODS DELIVER EDTO YOU UNDERTI IIS CONTRACT OR SALE, OR YOU, MAY, IF Y01T WISH COMPLY WITH THE INSTRUCTIONS OF THE SELLER REGARDING THE RETURN, SHIPMENT OF THE GOODS AT THE SELLER'S EXPENSE AND RISK. IF YOU FAIL TO MAKE THE GOODS AVAILABLE TO THE SELLER, OR IF YOU AGREE TO RETURN THE GOODS TO THE SELLER AND FAIL TO DO SO, THEN YOU REMAIN LIABLE FOR PERFORMANCE OF ALL OBLIGATIONS UNDER THE SALES CONTRACT, TO CANCEL THIS TRANSACTION, MAIL OR DELIVER A SIGNED AND DATED COPY OF THIS CANCELLATION NOTICE OR ANY OTHER WRITTEN NOTICE POST DATED BY 10/06/2022 "ICH IS (3) THREE BUSINESS DAYS FROM ORIGINAL DATE OF SALES CONTRACT DocuSign Envelope ID: 402C8799-F8A5-4E5F-816C-9423E6177174 __JPE OF WORK WEST BAY ENERGY (THE "CONTRACTOR-) SHALL FURNISH ALL MATERIALS AND PERFORM ALL THE WORK ON THE PROPERTY ADDRESS(THE "HOME") IN CONSIDERATION OF THE CONTRACT PRICE LISTED BELOW: CONTRACT PRICE THE CUSTOMER SHALL PAY THE CONTRACTOR THE TOTAL AGREED UPON SUM OF 32,214 ("CONTRACT "CONTRACT PRICE) FOR AND IN CONSIDERATION OF ALL MATERIAL AND LABOR THAT IS PROVIDED AND PERFORMEDUNDER ]'HIS SALES CONTRACT, THIS COOT RACTIS NOT CONTINGENT UPON FINANCING OR OTHER LENDER APPROVAL, CONTRACTOR DOES NOT PROVIDE FINANCING BUT WILL ASSIST CUSTOMER IN' SECURING OUTSIDE FINANCING AT THE SPECIFIC REQUEST OF THE CUSTOMER. SHOULD CUSTOMER REQUEST FINANCING ASSISTANCE, CONTRACTOR MAKES NO WARRANTIES OR REPRESE'NTTATIONS REGARDING CUSTOMER'S ABILITY TO SECURE OUTSIDE FINANCING, ITS TERMS, RATES OR CONDITIONS. NOTICE TO OWNER: DO'NOT SIGN THIS HOME IMPROVEMENT CONTRACT IN BLANK YOU ARE ENTITLED TO A COPY OF THE CONTRACT AT THE,TIME YOU SIGN. KEEP IT TO PROTECT YOUR LEGAL RIGHTS, THIS HOME, IMPROVEMENT CONTRACT MAY CONTAIN A moRxGAGE OR OTHERWISE CREATE A LIEN ON YOUR PROPERTY THATCOULD BE FORECLOSED ON IF YOU DO NOTPAY, BE SURE YOU UNDERSTAND ALL PROVISIONS OF THE CONTRACT BEFORE YOU SIGN. CONTRACTOR REPRESENTATIVE SIGNATURE: BUYER SIGNATURE: CONTRACTOR REPRESENTATIVE NAME: Frank Erickson BUYERNAME: James Converse 10/3/2022 DATE SIGNED: AS THIS CONTRACT MAY BE SIGNED IN THE FIELD AND VARIOUS PROVISIONS THEREOF ARE SUBJECT PRODUCT AVAILABILITY AND OTHER INFORMATION TO WHICH THE SALE REPRESENTATIVE MAY NOT HAVE ACCESS WHILE ON SITE, FINAL A.PPROVAI. OF THIS CONTRACT IS SUBJECT TO HOME OFFICE APPROVAL BY ]'HE CONTRACTOR. INSTR#2022220651 OR BK10705PG1980 Page 1 of I 10112/2022 11:52 AM Rcpt: 2512463 Rec: 10.00 CIS: 0.00 IT: 0.00 Nikki Alvarez-Sowles, Esq., Pasco County Clerk & Comptqer DocuStgn Envelope ICY: A2A831BB-$CFE-4010-AC16-8080974EAE66 Permit No. Parcel ID No 0 157 OOQO NOTICE OF COMMENCEMENT State of County of ___ Po So THE UNDERSaSNED hereby gives notice that improvement voll be made to certain read property, and fin accordance wth Chapter 713, Florida Statutes the following information is provided in this Notice of Conninencere-rdt. an No i Description of Property, Parcel Identiftc;h No. Street Address: �16 I 2, Cahouet Description of Improvement CIA, Owner Informat,on or Lessee iniamnation if the Lassies contracted for the improvement Mir Ilklays-0-- 7 F! Address City UWI� State- fi-hirest vi Property: ...... Name of Fee Simple Titleholder (If different from Ownw listed above) xrions �,, 4, Contractor: T , SUne Atfdreds City Slate Contractor's Telephone No., 5 surely Name Address LAY State Amount ofBone: S__­­­_____ Telephone No.: b. Lender - Name Address T, City State Lprce,'s —elephone No, 7, Persons winn the State of Florida oesignativid by the awner upor whom notices or other documents may be served as provided by Sectior, 713.13(i ha)t71, Florida Spruiles, c4y, State 8, Ir add4ion to himself, tire owner designates of o reivasve a copy of the Honor's Notice as provided in Section 713.13(i)(b), Florida Statutes, Telephone Number of Person or Entity Designates by Owner: (L Expration date of Notice of Cornmerressmert (the expiration dam may not be before the completion of construction are `net payment to the corraclzra but will be one year from the date of record rig untess a different Ccce Is specified): V`vARNING To OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713. PART 1, SECTION 7A,3.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENT$ TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RFCQRDFD AND POSTED ON THE JOS SITE BEFORE THE FIRST INSPECTION- IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCZ WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT, Urder penalty or penury, I declare that I have reail, the foregoing notice of commencement ard trial the facts stated therein are true to the Dest of my knowledge anti belief, STATE OF FLORIDA COUNTY OF PASCO Si ' fjy'Owner of Lessee, or Owner's at Lessee's Ailthonzed Officar/D recoolPtinnerWariage, NA Signatory Trtle,0fice The foregoing insirumerd was acknowledged before me day of 20L/ , by 0 VU raney in fact) to, (type of authority, e,g,, officer_ truetee lor y nrbehalftrivitt let train md), m cecnally Knoren [j OR Produced Idenfific famaq, Signatures was "ne"" AA - I ype of identification Produced Nance (Print} AA Alicia Smith 'Illy -0 Com.m4HH1100403 a it s:March 4,2025 Bonded Thru Aaron Notaq RD 102;j RDG Engineering, Inc. Ryan Goolabsingh, P.E. Florida CA #32850 951 Brickell Avenue, #3605 Miami, EL 33131 786-423-2285 October 7, 2022 Contractor: West Bay Energy Project: Jim Converse 6551 Northlakes Dr, Zcphyrhills, FL 33542 System: Solar PV System RE: Compliance Letter To whom it may concern: I certify that the structural and electrical installation of the solar PST system, as designed, will not adversely affect the building structure under normal conditions or during a hurricane event of the FBC specified intensity. The intent of this letter is only to verify the loads imposed on the roof as compared to the design loads of the permitted structure, per Florida Building Code 2020. This letter does not certify the installation of the solar PV system by means of inspection. In addition, the installer shall notify me, the engineer of record for this project, if the roof or roof frarning is not sound or in good condition. If the roof is not in good condition, a thorough structural inspection shall be conducted and if necessary, an additional letter and or revised drawings will be provided, prior to installation. l I I I I I I Regard�s° No.82345 ),Q/07/2022 4/1 E Ryan Go6lab E STATOF 10NAL t�' Ltol-Itoxvil PROJECT: 22221 JIM CONVERSE__ DESIGN CODE: FLORIDA BUILDING CODE 2020 Vint, 137 _MPH_ Vosd'i 107 MPH EXPOSURE CATEGORY; C :.:RISK CATEGORY: 11 ROOF 7t'PC I R ROOF SLOP: 23 DEGREES G;j 0.85 i12Hei`ht?tPanel above 5 M di to Roof Ed e 8 ft dito Ad'acenY¢tta" 8 _ ft d2 to Ad'acent Panei. 8. ..�".",.... ft "Exposed" ClassiEteafion 1. NOT EXPOSED Exposed" Classification 2. NOT EXPOSED e- 1 ASCC 7-16 29.4.4 .N4 0,65ASCE 7-16 FIG 29.4.8 MAIN WIND FORCE CALCULATION: %_0.00256°Kz'Kzt'Kd,v q,,,= 21.1 PSF ROQF CQMP(idENTS AND CLADDING CALCULATION PANFt WIDTK 40.8 IN PANELLENGTH 69AIN PANEL. AREA: 20 FT' ROOF COMPONENT AND CLADDING PRESSURE: AREA ZONEI ZONE 2E, 2R 70NE3 MCAN ROOF HEJGI IT 16 FT BUILDINGWIDTH �.64 FT BUILDING. LENGTH Kzt _ 79 Fr 1.00 Kd: 0,86 Kz: 0,86 t ENCLOSURE CATEGORY tNTERNAC PRESSURE COEFP€ 6.40 FT O en i)'v Arra 0.0p Ekhxsva�t�J n�.<A.:P gh(GCp) 7 SF 10 USE 100 SF PUS I NEC I LOS BEG POS NEG 14,761 29.52 14,76 -29,52 -9.60 -16.87 14.761 42,17 14.76 -42,17 -9.60 -25.97 14.76 -42.17 1.4.76 -4217 -9.60 -75.97 PANEL PRESSURES PER ASCE 7-1629.4.,E h(GCa! e)(ya) EXPOSED NON EXPOSED �10� POS NEGZONE]ZONE' 2F, 2RZONE 3 FPfflEL�EC.K WIND PRESSURE PORTRAIT-(2R-NON EXP) -24.2 PSF PANEI. CAPACITY PORTRAIT -75 PSF OK WIND PRESSURE LANDWAPE- {2R-NON EXP) -24.2 PSF PANEL CAPACITY LANDSCAPE-33.4PSF OK EN -CALCULATION WIND PRESSURE- QR-NON EXP) -242 PSF MAX, MOUN'TSPAN OVFR ROOF-: JOISTS: 4 FT (ASSUMES MAX ROOF JOIST SPACING OF 24") MAX. MOUNT SPAN ALONG ROOF JOISTS: 7.89 FT (REAM TRIRUTARYWIt)TH=Lr2 PANEL LENGTH) WIND LOAD ON RAIL_ 70 LB/FT RAIL MAX ALLOWABLE SPAN`. 1: 4FT OR GREATER OK RAILMOUNTCONN£CTI tQ�CAI.G�}UITIfjN4 UPLIFT MOUNT CAPACITY: 64Q t6 MAX RAII. REACTIONS: SPACING ZONE i EXPOSED 331A LB ZONE 2E, 2R EXPOSED 480.7 LIT ZONE 3 NON -EXPOSED m 3205 UZONE 2F, 2R NON -EXPOSED 32GS 1A70NEi NON EXPOSED 22IG LB LATERAL MOUNT CAPACITY: 275 1.B LOAD DUC TO GRAVITY SDL- 2.5 PSF Fdl= 2.5 PSF-PANEL LENGTI11(2' 12)'SPACING 29 LB Rd1=SfN(SIOPF")'Fdl- I LB INTERACTION (WORST CASE): 0.79 tW 1: JSFF MANUFACTURERS SPECS) LAG BOLT DIA; 0.3125 IN LAG BOLT AREA. 0,077 IN, LAG DOLT STRENGTH: I00,000 PSI LOAD: FACTOR 1.67 1 AG SCREW CAPACITY 4590 1.6 OK ANCHOR EMBEDMENT 35"INTO SUBSTRATE ALLOWABLE WITHDRAWAL CAPACITY W= W x Cd x Cm x Ct x Cog x Ctn x n x 3.5" W=307lb 0=1.6 Cm-1.0 Ct-IO Ceg=1.0 Ctn-1,0 G=0.55(MIN.) n-1ANCHOR(MIN.) W'= 1719 LR ox_' NOTES: 'MEMBERS ARE PRODUCED FROM ONE OF THE FOLLOWING ALUMINUM ALLOYS: 5005-T5, 6105-T5, 6061-T6 mAxrc . No.82345 Y ° 10/07/2022 ( ° STATE OF', F(J d RI Y ) \ EIN(IN ,,fflR1,NE DRAWINm R N DPAWING Pm�) M) IT q q ELECTRICAL DATA I STC- LINEAP PERFOPMANCE WARRANTY (41C t 497 ,_cum rexx @ 25 Ycar Product watranty 25 Year Linear 11ower W-,irranty 01 `1 P SOLAR PANEL BLACK HP M390-AlF 390W 1000V MECHANICAL DATA TEMPERATURE CHAPACTERISTICS SPECIRCAl iONS Q. e Ter T i j e Cuel i i,:, Homl! iH" Q 11 i I t ro= s of u r a 1 z I I f I IJ I f 1 1 "V 1 Learn More: I ea cl e rs: Alest USA Loc�t'lor": EasL U)SA k-ocauon: j" T:gCr,,tQ' JN N,19W 10880 Wilshire Rh,101 'd Suite 11, Pockcto -��17,) 11, 1 1 llcr o I os Aingcs. CA 90, USA Nov, ',ork, N'100?0, ('15A 1 {,W 4,97 71120i t 8,5,5) 2 5 4 024 7 1 q8, 42,.86 *1(3,23) 1 IT 30 1 1 9" (646 IQ8 and IQ8+ Microinverters Commonly used module pairings' W 235 ­350 f 235-440 Module compatibility 60-cell/120 half -cell 60-cei3/120 half -cell and 72-oe1l/144 half-cefl MPPT voltage range V 27-37 29-45 Operating range v 25-48 25-58 Min/max start voltage V 30/48 30/58 Max input DC voltage V 50 60 Max DC current' [module Isc] A 15 Overvoltage class DC port Ii DC port backfeed current mA 0 PV array configuration IxI Ungrounded array; No additional DC side protection required; A6,i,'.rV-Mf ,r,,—r,,,.,2OAwbrairciT-cir,-uW' Peak output power VA 245 300 Max continuous output power VA 240 290 Nominal (L-L) voltage/range' v 240 /211- 264 Max continuous output current A 1,0 1.21 Nominal frequency Hz 60 Extended frequency range 117 50-68 Max units per 20 A (L-L) branch circuit' 16 13 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting Lo Grid -tied power factor (adjustable) 0.85 leading - 0,85 lagging Peak efficiency % 97Z 97.6 GEC weighted efficiency % 97 97 Night-time power consumption MW 60 Ambient temperature range -401C to 60W (-401F to -114011F) Relative humidity range 4% to 100% (condensing) DC Connector type MC4 Dimensions (HxWxD) 212 mm MY) x 175 mrn (6-91 x,30,2 men U.2") Weight 1,08 kg (2,38 lbs) Cooling Natural convection - no fans Approved for wet locations Yes Acoustic noise at I m <60 dBA Pollution degree PD3 Enclosure Class 11 double -insulated, corrosion resistant polymeric enclosure Environ. category / UV exposure rating NEMA Type 6 / outdoor CA Rule 21 (UL 1741-54 UL 62109-1, UL.1741/[EEP1547, FCC Part 15 Class 8, ICE-5-0003 Class B. CAN/CSA-C22,2 NO. 107,11-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C223-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to manufacturer's instructions. (1) No enforced DC/AC ratio, See the compatibility calculator at https://Iink.enpFa5e,com/ module -compatibility (2) Maximum continuous input DC current is 10,6A (3) Nominal voltage range can be extended beyond nominal if required by the utility, (4) Limits may vary. Refer to local requirements to define the number of rnicroinverters per branch in your area, 108SP-DS-0002-01-EN-US-2021 =10-19 Enphase IQ Combiner 4/4C MODEL NUMBER IQ Crmob! nor 4C (X-1Q-AMI-2-10-4l.') 10,1-1(-,obir-o�r 43 ovr Enphose 10 Gwewa}r printed c rcuit board for Integrated revenue gracle Po/ Produclron melenng 'ANSI C 12 10 +r 0,5%) and con:3ljlrlpflon moritoring 5%), InBile s Enp-iase Mob,lp Cmmec, i.oNlOrmoden, (C E 1, Llhn DEM-.N,11-06,,SP-0'), a cell M00.0l"ri for -owteats 'Ut) to of) n1WR)MVxWC,,!5. andtodefiect!ieat. ACCESSORIES AND REPLACEMENT PARTS (tot included, order separately) C i -u.wit B r P a k e ns S u p po rit s E a t on 8 R 2 10, B R 2`15, 3R220, 8R230, BR 240, 8 R 2 5 9, 1 it d B R 2 6 0 c t rc i a bre-a k o rs. BRK-1 OA-2-240V Circm! breaker. 2 pole, 1 OAEaton 3E22 10 BRK-ISA-2 240V Dicuit breAker, 2 pole, 15A, Fa,00 BR21b FiRK' ",0A-2P 240V Crcul bre..,,lker, 2 pole, 20A, F-ao"on BR220 l3p,3-1 5A-2P-240V B Circuir breaker, 2 pole, I 5A. Eaiol) BR21513 with hold down 0 soppo,l Moo 20A-2P 240V-9, Cirl;tA biealke,,, 2 pole, 20A, Eaton 9R2206 wW, hokd ldc,,,Nn 10 support EPI-C-01 Powor lute sat rier (corrumomication bridge parr), quanlity - one pair XA SC-t-ARSHIELD-ES Realacenne,solar sh'eo' for IQ Comet I cr A I,!, C XA-PLUG-120-3 Accessory receptaclelkor Power Line C-,)Wer in if) Corribiner 4,/4C (required for EPLC-00) XA----NV P;-'BA-3 Rep';acenient IQ Gateway printed circuill board (PCB) for Compr/4t', mer 4, X-1Q-N/VHD-125A Hold down kit for Later) circrift breaker with screws, ELECTRICAL SPECIFICATIONS Continuous duly Systotn suit age 120/240 VAC', 60 Frz Eaton BR serles busbar rating 126 A fvlaxcontmuouo culrent mbng 65 A Max, rating(Inputfrom PV/Storage) 64A Max, fuse/drcuit rating foulprit) 90 A Branch circults (solar and/or storage) Up to four 2-polo Eaton BR series Distributed Generition (D(3) breakers only (nal inchided) Max, total branch citcult )-oaker tating Iron ut), BOA of distributed generation, 95A with 10 Gateway breaker included lxnsduc,flon metering CT 200 A solid core ore -installed and Mredto IQ Gateolay Consamp.don lnonionng CT ICI-N)O-SPLI T) A Dais of 200 Asplil core Ckjilrter l 'i ansfouners MECHANICAL DATA ilnensions (VVX1,-lX0) 37,5 x 49,5 x 168 ere (14,75" a 6,63'), Hekght is 21,06" (53,5 are) with rnounbng brackets, WeigN 7, 5 kg (16,5 1 b s) Arnbieot lernperature rang e -4011 C to +4611 C (-401' to'11,a F) COO! ng Wouracolweci,on, pws shield Encrotoire environmental rating Outdoor, NFITL-coorfified,!NENIA type 3R, polycarbororte constriaction W,re siles 20 A to 50 A breaker inpUts,. 14 to 4 AWG copper ,conductors 60 A br-aket branch riput: 4 ic, 110 AVVG cot,)per conductors Md4l Wg conibiredoutput 10, to 2/0 AWG copper conducires Neri-irai and ground: 14 to l,'O coppor conductors. Akoays fo1ovv local code requirements for conduc-,cr sering. Altitude To 2000 nriebst (6,560 feet) INTERNET CONNECTION OPTIONS ... ...... . .... Integrated wi, Fl ....... .. ............. C01,11ar CEA, L M ODEM -M1 C) 6-SP 05, CE lA-M 0 1) M- M 1 -0 6 AT 0) 5 (4G rased L IF F M 1 ceflular rnoden,,). Note r1st an Enphase Mot,qv Connectcellular mode.m is rea1wreo for Ensemble i ,stally fiors. Elherre,! Optionat, 802.3, CraSE (or I(Qit 6) UTP Elhornet cable (not incruded) COMPLIANCE "ininnh,nce, 11 Gatowav UL 60601 I/CAWSA 22,2 No, 6 101,10 1 To learn more about Eriphase offerings, visit e p gie ENPHASE W, oll�� ,3!(" 1 �q Ai qkt, I PANEL OVERHA&4G FRCV RNLS TO BE EQUAL ON BOTH SIDES AL-ERNKrE SQE UNIS* MAX, TV PANEL AREA NOT TO EXCEED 22.0 SO M !Pv MODULES UP -10 80.4" LONG AND 22,O SO. F.( ­­ 1 1 PAC CANTILEVER RAJ, SPAN LEND-H RAIL SPAN LENGTH 'RAIL CANT!iEIVER PV M=)-E NOT PAR7, Ok TKS APPROVAL. SEE SEPARATE Pi MANU', PUBLISHED /-DATA FOR RATING AND D---TA'LS, MAX PV PANEL AREA NOT TO EXCEED 22.0 SO FT ----------- PANEL MOTH IDIH� -i \_'R_IG RAIL _TYEh_'AL F-11YAD—ON XR-10 RAIL INTERPOLATION BETWEEN CHART VALUES ALLOWED. XR- 10 RAIL(S) EQUIMSTAN7 (OPT IONAL) Seated: 1112120 on== OEM mm< I III crowing no, 19-51F Pad scrims any Deck Mount, Black Part 4e - " lterra _.vsca•ipii€an in NO Kit I i Nbnca Deck Mount A,sea€ably l Nano Deck Mount Nano Gasket i I I � I I 2 Deckingy Screw Ass�>mk, � � a Self Tapping Screw, #6.3 Y 76 I � Sealing a,NcsshE.s .261D X .;aC?X . i 25 i i 4 i t, ,i 1, Nano Mount ..,.a 01 E c I �- I _ i Material,, AILIMinU t Finish: 81rtck Powder Coating 2. Nano Gasket ✓ f 1 I f ! { S Materiak USWR Gasket with Adhesive OCK {f Material: Stoinde s Suet Finish: C leU -,i" ( i MsJ � ( i NAaterioL EhPDM ;ir Stainless Steel` 0102.14 11002 D#t're-miomf shown i,Ylt` ii,Qhey fond millin P.2w s') Details are subject to change t\'4f .oul notice DESCRIPTION g1sseetantisaone-component,smooth polyurethane adhesive capable ofdynamic in|mmovement totaling 70% of original geometry (±35%),The sealant cures toatough, flexible rubber when exposed tnmoisture present inthe atmosphere. Bostik 915 all seasons formula has physical properties that will. remain relatively stable over time. The cured performance temperature range is-4oOFtn/sOOFWhere textured appearance isneeded, please use 8og1kg18. APPLICABLE STANDARDS ASTMCD2OTYPE S,GRADE wS,CLASS 35USE NTAAwDw ' usFederal Specification TF- S0O23oC(Cumo-wcS)for one -component sealants asClass A,non-sag CxHg.S[AQMD,and OTC compiiant Canadian Specification CAN /CGSB/Ql3-n87 ' Miami -Dade County, pLoUda.NOANo.:1l0423z0.0S/24n7 ' Miami'DodeTASlU2Static Uplift Resistance AAMA80B Axn4|O0/200/30Ninstallation requirements BASIC USES 915 isdesigned for app8cationsfrom foundation tofinish and is Ideal, for, seating expansion and control joints, tik tip joints, perimeters of d000, windmws, and other wait penetrations. It has tenacious sealing and bonding performance for many roofing applications, metal roofs, gutters, roof tile installations, dashing and sheet metal, appiicat|nns, 915 cures to form u guraU!e, frexible bond with most building materials such osstone, foam, mamnry.ceramic, wood, stee(. Kynart" coated meraband coppurmnVmost other metals. |NSl0ALLATION PROTOCOL Miamil-DmdeMate m1oinadjacent surfaces primnothe8ostikQ1uskinning and subsequent curing, mmaximize wetting potential of thesea[ant to the substrates. A11ow fult-cure, typically 7 days, prior toany mechanical stress testing procedures. |tisrecommended U`atadhesiontesting beperformed uucapture batch control qualities ofproposed substrates. Joint Design: in general, more /nint movement can be accommodated }nathin bead ofsealant than athick bead. 8nst|k g|Sshould bcnothicker than v2''<127mm>and nothinner than 1/4" (6,4mm). In /oincs between |/2" and r, the ratio of sealant width todepth should beappmximatay2:1. Sealant depth \nimints between 1*r'and 1/2^should Ue1*r'deep, Joints with dynamic movementshouLdnot Uedesigned it) widths tessthan1m'. Surface Preparation: Surfaces must b*structurally clean, dry (no frost) and structurally sound, free ofcontaminants, including, bur, not limited to, dust, dirt, loose particles, tar, asphalt, rust, m[Koil, etc If Substrate is painted or coated, scrape away at[ loose and weakly bonded paint orcoating. Any paint orcoating that cannot beremoved must betestegmverify adhesion ufthe seuLantnrto determine the appropriate surface preparation |fneeded. isee ASP section nnnext page for de<n|ls.} Backer Rods and Bond Breaker Tapes: Bond breakers |nduding, but not Limited to, ckoed-ceKpo(yeuhy(enebacker rods are used tocontmidepth ofthe sealant bead, provide afirmtooting surface n�airmedes°w( �!, it Mlrmwu�t,puu�=�°�"wwmom�� GtNERAL NOTES, 1. THE GOVERNING CODE FOR THIS PROJECT IS THE FLORIDA BUILDING CODE 2020, 7th EDITION, THE NATIONAL FIRE PROTECTION ASSOCIATION CODE (NFPA 1 2018), AND THE NATIONAL ELECTRIC CODE 2017. 2, TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THESE DRAWINGS AND SPECIFICATIONS COMPLY WITH ALL REQUIREMENTS FROM THE GOVERNING BUILDING CODE, 3. CONSTRUCTION IS TO COMPLY WITH THE REQUIREMENTS OF THE GOVERNING BUILDING CODE AND ALL OTHER FEDERAL, STATE, AND LOCAL BUILDING CODES. 4, IF INSTALLED PER CODE AND APPROVED ENGINEERING PLANS, THE PHOTOVOLTAIC SYSTEM WILL NOT ADVERSELY AFFECT THE STRUCTURAL INTEGRITY OF THE EXISTING ROOF AND/OR THE BUILDING. 5. AT ALL TIMES THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE CONDITIONS OF THE JOBSITE INCLUDING SAFETY OF PERSONS AND PROPERTY. 6. DRAWINGS HAVE BEEN PREPARED BASED ON AVAILABLE KNOWLEDGE OF EXISTING CONDITIONS PROVIDED BY THE CONTRACTOR. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING DIMENSIONS, ROOF FRAMING, AND ELECTRICAL COMPONENTS PRIOR TO COMMENCING CONSTRUCTION. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING SOUNDNESS OF ROOF STRUCTURE PRIOR TO INSTALLATION, E.O,R. TO BE NOTIFIED IF EXISTING ROOF STRUCTURE OR ROOFING IS NOT IN SOUND CONDITION, 7. ENGINEER HAS NOT VISITED THE JOB SITE AND SHALL NOT BE HELD RESPONSIBLE OR LIABLE IN ANY WAY FOR ERRONEOUS OR INACCURATE INFORMATION, DATA, OR MEASUREMENTS THAT HAVE BEEN PROVIDED BY THE CONTRACTOR. 8. WORK SHALL BE FIELD VERIFIED BY THE CONTRACTOR AND THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 9, ENGINEER IS NOT RESPONSIBLE FOR ORIGINAL DESIGN OF ROOF STRUCTURE OTHER THAN TO CONFIRM THAT PROPER CONNECTIONS CAN BE INSTALLED AND THAT LOADS FROM THE SYSTEM ARE LESS THAN THE ROOF DESIGN LOADS PER FLORIDA BUILDING CODE. ALL EXISTING STRUCTURES MUST BE PERMITTED PRIOR TO INSTALLATION. 10, DO NOT SCALE DRAWINGS TO OBTAIN DIMENSIONAL INFORMATION. 11. PRODUCT DATA SHEETS ARE PROVIDED FOR REFERENCE ONLY. REFER TO MANUFACTURER FOR SIGNED AND SEALED DRAWINGS AND CALCULATIONS. STRUCTURAL NOTES: 1, RAIL/ FOOTING/ CLAMP MATERIAL: PER MANUFACTURER (6005-T5,6105-T5, S6061-T6) 2. GRAVITY LOAD: SOLAR PANEL WEIGHT: <5 PSF 3. WIND LOAD: DESIGN CODE: ASCE 7-16 MEAN ROOF HEIGHT: 16 FT ROOF TYPE: HIP ROOF SLOPE: 23 DEGREES RISK CATEGORY: 11 ULTIMATE BASIC WIND SPEED: vue 137 MPH Vasd- 107 MPH EXPOSURE CATEGORY: C INTERNAL PRESSURE COEFFICIENT: +/-0.0 (PANELS ARE OPEN) TOPOGRAPHIC FACTOR: KZt= 1,0 DIRECTIONALITY FACTOR: Kd= 0,85 CORNER ZONE: a = 6'-5' ASCE 7-16 DESIGN COMPONENT AND CLADDING ROOF PRESSURES FOR BUILDING HEIGHTS LESS THAN 60 FT PER FIG. 3&5-1 0 L _j L- - - - - - - - - 01 0 if Ftat rwf, 8� 7 ft rem Gabile-roof PLAN Hiproof ELECTRICAL NOTES: 11 THE PHOTOVOLTAIC SYSTEM COMPLIES WITH THE REQUIREMENTS OF NEC 690. 2. THE SOLAR MODULES SHALL BE THE NUMBER, MAKE, AND MODEL LISTED ON THESE DRAWINGS. ALTERNATIVE MODULE MANUFACTURERS MAY BE CONSIDERED IF OUTPUT, PERFORMANCE, AND PROPERTIES OF MODULE ARE MATCHED. 3. THE PV MODULES WILL BE INSTALLED IN STRINGS OF THE NUMBER OF MODULES SPECIFIED WITHIN THESE DRAWINGS, 4. POWER CENTER ASSEMBLY COMPONENTS SHALL BE THE NUMBER, MAKE, AND MODEL LISTED ON THESE DRAWINGS. SUBSTITUTIONS ARE NOT APPROVED WITHOUT WRITTEN AUTHORIZATION FROM THE E.O.R AND OWNER. 5. WIRING SHALL BE AS SHOWN ON THESE DRAWINGS. ALL AC & DO WIRING SHALL USE 10 AWG COPPER MINIMUM, UNLESS NOTED OTHERWISE. OEM WIRING AND HARNESSES, REGARDLESS OF WIRE SIZE, ARE ACCEPTABLE WHEN APPLIED TO THE OEM USE INTENDED, SUCH AS PV-MODULE TO PV-MODULE CONNECTIONS. 6. PV MODULES PRODUCE ELECTRICITY WHEN EXPOSED TO DIRECT SUNLIGHT, IT Is THE CONTRACTORS RESPONSIBILITY TO KEEP THE MODULES COVERED WITH OPAQUE MATERIALS UNTIL ALL WIRING IS COMPLETED. 7. USE OEM PLUG CONNECTORS BETWEEN PV MODULES. TERMINATE IN WATERTIGHT JUNCTION OR COMBINER BOXES. 8. ROOFTOP -MOUNTED PV` PANEL SYSTEMS SHALL BE UL 1703 AND 2703 COMPLIANT PER FBC. 9. DO NO LEAVE LOOSE UNSECURED WIRES/HARNESS BETWEEN PV MODULES, 10. USE APPROVED MEANS AND METHODS PER 2017 NEC AND ADHERE TO MEANS AND METHODS OF NRCA ROOFING & WATERPROOFING MANUAL TO ENSURE NO ROOF LEAKS. 11. E.O.R. IS NOT RESPONSIBLE FOR THE AMOUNT OF KILOWATTS PRODUCED BY THE SYSTEM OR GENERAL PERFORMANCE OF SYSTEM BEYOND SAFETY AND CODE COMPLIANCE, THE SYSTEM IS DESIGNED TO SUPPORT THEM IMUM PRODUCTION BASED ON IDEAL CONDITIONS AND THE INFORMATION PROVIDED TO THE E.O.R BY THE SALES PERSON INSTALLER. OWNER TO CONTACT SALES PERSON / INSTALLER REGARDING ENERGY PRODUCTION AND TERMS OF SALE. PV SYSTEM NOTES 'L APPROXIMATE ROOF AREA: 3,800 SF 2. PV SYSTEM DESCRIPTION: GRID -TIED 3. INVERTER ENPHASEIQ8+ 4, TOTAL MODULES: 30 MODULES 5. TOTAL STRINGS: 3 STRINGS 6. TOTAL POINTS OF CONN. PER MODULE: 4 CONN. 7. PV SYSTEM RATING: 11,700 WATTS STC RATED DO ENERGY 8. ESTIMATED ENERGY PRODUCTION/DAY: 49.2.kWh (SEE NOTE 11 ABOVE) 9. INVERTER HAS MAXIMUM POWER POINT TRACKING (MPPT); MEETS REQUIREMENTS OF 3-P POWER AND I-P POWER; MEETS IEEE 1547; MEETS UL 1741. 10. SYSTEM AUTOMATIC OPERATION: a. GRID POWER IS PRESENT, PV SYSTEM FEEDS THE LOAD DURING THE DAY TIME. b. GRID POWER IS LOST, PV SYSTEM AUTOMATICALLY DISCONNECTS FROM THE GRID, c. PV SYSTEM WILL AUTOMATICALLY RESUME FEEDING POWER TO THE GRID WHEN THE PROPER GRID VOLTAGE AND FREQUENCY IS RESTORED PER IEEE STANDARDS AND THERE IS ENOUGH SUNLIGHT. DRAWING INDEX DRAWING NUMBER DRAWING NAME N LU C1.0 GENERAL NOTES 0 E1,0 ELECTRICAL 0 S1.0- STRUCTURALPLAN 0 S2°O STRUCTURAL DETAILS 0 1, RYAN GOOLABSINGH, P.E. #82435, AM THE ENGINEER OF RECORD FOR THIS PROJECT AND ATTEST THAT I HAVE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN CONTAINED IN THIS SET OF PLANS, PER FLORIDA STATUTES 6IG15-18.01 1. LABELS 3/8' TEXT SIZE (MIN.), NONSERIF FONT U.N.O. USE DURABLE ADHESIVE FOR ALL LABELS. ALL LABELS TO USE WHITE LEI TERS WITH RED BACKGROUND AND SHALL BE UVRESISTANT, REFLECTIVE (WHERE NOFED), WEATHER RESISTANT, AND SUITABLE FOR THE ENVIRONMENT PER 11,12,�',ll UVREINsrANTMARKERS SHALL BE USED FOR WRITING ON LABELS REQUIRING INSTAL LER-WRIF IFN VALUES, LABEL NOTES LABEL, NOTES I-ABEL NOTES NEC 690,51, PERMANENT LABLE. WARNING PHOTOVOLTAIC POWER SOURCE APPLY L 0 AS D CONNECF ELECTRIC SHOCK HAZARD APPLYTOAC DISCONNECT WARNING APPLY TO MAIN SERVICE AC OUTPUT CURREIII =37 AMP Eg= jj!S & P(Ct OF DO NOT TOUCH TERMINALS, DISCONNECT PANEL SERVING AC OPERATING VOLTAGE = 240 VOLT INTERCONNECTION TERMINALS ON BOTH THE LINE AND AC AND DO PV SYSTEM, REFLECTIVE LOAD SIDES PAY BE ENERGIZED IN APPLY 10 ALL DC CONDUITS, THE OPEN POSITION RACEWAYS. ENCLOSURES, CABLE ASSEMBLIES EVERY WARNING zE APPLY 10 AC 10FT, AT TURNS, ABOVE AND POWER SUPPLY CONNECT& POINT 8F`INTERCONNEC,T PV SOLAR BREAKER D�SOONNECT AT PANEL BELOW PENETRATIONS, AND 2UAL !ON FR'OM INVERTER ALL SO COLABINER AND SOURCES UTILITY AND PV SOLAR LABEL. SIZE: AW 1) NOT RELOCATE THIS OUTPUT JUNCTION BOXES. ELECTRIC SYSTEM OVERCURREITT DEVICE (WHERE OCCURS) REFLECTIVE. TEXT SIZE AT MAIN SERVICE DISCONNECT Pk9GTQJ�"`LTAtC DISCONNECT APPLY TO fa APPLY TO AC DISCONNECT DISCONNECT AT APPLY TO AD RAPID SHUTDOWN FOR SERVICE CALL DISCONNECT & SWITCH 'INSTALLER NAME' Or m INSIALLER'S PHONE NUMBER"POINT INTERCONNECTION 0 rr LU Ul Ul u- Cc 0 0 Z 44 LLI ul (0 CL C) u w N CL ■ ...... Tilll No.82345 10/07/2022 44/ ,--STATE OF NAL" ISUED/REVISED _,cu;Rranam care GENERAL NOTES DRAVIN BY RUG DATE lox,7/2022 cl .0 PRODUCT INFORMAT [ON ITEM MANUFACTURER MODEL LISTING/COMPIANCE PV MODULES MITREX M390-AIF UL INVERTER ENPHASE IQ8+ UL ALL DISCONNECTS ENPHASE DO & AC UL ALL OVERCURRENT ENPHASE PROTECTION :�� PER FL. STATUTE 377.705 (REVISED 7/1/2017L 1, RYAN GOOLABSINGH, P.E. 482345, AN ENGINEER LICENSED PURSUANT TO CHAPTER 471, CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE. 2. REFER TO GENERAL NOTES ON CI,O FOR ADDITIONAL INFORMATION. 3. PROVIDE 46 BARE GROUND WIRE TO JUNCTION BOX ON ROOF AND #8 IN CONDUIT FROM JUNCTION BOX. 4. EXISTING METER TO BE CHANGED TO A NEW METER BY UTILITY AFTER THE FINAL INSPECTION. 5, PER NEC250.58, WHERE SEPARATE SERVICES, FEEDERS, OR BRANCH CIRCUITS SUPPLY A BUILDING AND ARE REQUIRED TO BE CONNECTED TO A GROUNDING ELECTRODE, THE SAME GROUNDING ELECTRODE SHALL BE USED. 6. NEW MAIN BREAKERS SHALL BE SECURELY CLIPPED f FASTENED TO BUS BAR PER NEC (WHERE OCCURS). 7 TAP IN MDP: MAX RATING MAIN SERVICE ENTRANCE CONDUCTOR SIZE. LINE SIDE TAP CONNECTION IN MDP WITH PIERCING TAPS BETWEEN METER LOAD SIDE AND EXISTING MAIN DISCONNECT. TAP SPACE TO BE VERIFIED IN FIELD PER NEC 312,8. IF SPACING REQUIREMENTS ARE NOT MET. PROVIDE PIERCING TAP BETWEEN METER AND MAIN DISCONNECT IN METAL GUTTER OR ENCLOSURE W/ MIN 8"X8'X24'SIZE. TAP CONDUCTOR SIZE: MINIMUM 6 AWG COPPER OR 4 AWG ALUMINUM PER NEC 230.42(B) AND 310.15(B)(7) OR 310.15(B)(16). TAP CONDUCTOR LENGTH IS LIMITED TO 10 FEET PER NEC 705,31. 8. MODULE FRAMES AND RACKING SYSTEM SHALL BE BONDED USING GROUND LUGS. SEE DIAGRAM ON 3/E1.0. GROUNDING SHALL BE CONTINUOUS FROM ARRAY TO EXISTING SERVICE GROUND SYSTEM PER NEC 690.43 AND 690.47, 9, PROVIDE PLAQUE PER NEC 705A 0 AT EACH DISCONNECT SHOWING LOCATION OF SERVICE DISCONNECT ING MEANS AND PV DISCONNECTING MEANS WHEN TAP IS USED AND DISCONNECTS ARE NOT IN THE SAME LOCATION, 10. CONDUCTOR SHALL BE ROUTED IN RACEWAY AND INSIDE PANELBOARD, INCLUDING THE GROUNDED CIRCUIT CONDUCTOR (NEUTRAL), PER NEC 300.3 AND 25014(C). III . (30) MICRO -INVERTERS: TOTAL AMPS = 30 X 1,211A = 36.3A TOTAL 2P 240V 20A BREAKERS = 3 ELECTRICAL BREAKER RATING: 200A WIRE CAPACITY 410 WIRE ON RCOF= 40 AMPS PER NEC 310A6 91 DEG F DESIGN TEMP (CONDUITS / RACEWAYS J" MIN. ABOVE ROOF) => CORRECTION FACTOR = 0,96 PER NEC 310.15(6) MAX 9 CONDUCTORS IN A SINGLE CONDUIT => CORRECTION FACTOR = 0.7 PER NEC 310,15(C) ADJUSTED CAPACITY OF #10 WIRE = 40A X 0,96 X 0.7 = 26.9A #10 WIRE @60 DEG C = 30A => CONSIDER 26.9A ESTIMATED MAX AMPS IN 410 WIRE = 13 (MAX) X 1,21 A X 1.25 = 19,7A , 26.9A #6 WIRE ON WALL = 75 AMPS PER NEC 310,16 91 DEG F DESIGN TEMP - CORRECTION FACTOR = 0.96 PER NEC 310.1 5(B) MAX 3 CONDUCTORS IN A SINGLE CONDUIT => CORRECTION FACTOR = 1,0 PER NEC 310 15(C) ADJUSTED CAPACITY OF #6 WIRE = 75A X O.96 X 1.0 = 72A 46 WIRE @60 DEG C = 55A => CONSIDER 55A ESTIMATED MAX AMPS IN #6 WIRE = 363A X 1.25 = 454A , 50A TO UTILITY 200A I 240V SERVICE PV MODULE----,___",,, 13 2 ALL CONDUITS TO BE 7/8' DENOTES QUANTITY OF (MIN.) ABOVE ROOF MODULES IN CIRCUIT. OK TO ADJUST IN FIELD. MAX MODULES= 13 PER STRING. ENPHASEIQ8+ SEE Cl .O FOR ALL SAFETY LABELS REQUIRED, MICROINVERTER ATTACHED UNDER MODULE (TYP.). NEC 690,12 CODE COMPLIANT ENPHASE 10 TRUNK CABLE ( ' 0-12-240)#12AWC; THHN-THWN-2 (UL 9703) -72 F 8-1 EXISTING SERVICE 200A / 240V (SEE NOTE 4 PER fiJE1,0-} SEE 51.0 FOR APPROXIMATE LOCATION METER EXIST. (3)-4/0 WIRE MIN. (Vil,) NEUTRALAND GROUND BONDED GROUND INTERSYSTEM BRIDGE PER NEC250,94 EXIST. MDP 240V F 2U'JA (MIN., V.LF j SEE Sl,O FOR APPROXIMATE LOCATION. PIERCING TAP IN MDR, SEE NOTE 7 ON I /E 1,0, LOCKABLE DISCONNECT SEE 51.0 FOR APPROXIMATE LOCATION NEUTRAL AND GROUND BONDED AC DISCONNECT 66A / 240V-SERVICE RATED N FUSED AT 50A J` GROUND ROD mm (3)-#6 THWN-2 IN � MIN. DIA. PVC OR OTHER NEC COMPLIANT CONDUIT CI LLI Lu III BARE COPPER uj Pj N, GROUND WIRE II z uj 0 O� LL WOO ni 'tf Dot 0 1 >- Lij CL 0 0 LL[ W 0� X X N L PVC J-BOX NEMA-3R-3R 6X6X4 (UV RATED) (2)-#10 THWN-2 FOR EACH CIRCUIT AND (1)-#8 GROUND NJ" MIN. DIA. PVC OR OTHER NEC COMPLIANT CONDUIT ENPHASE SOLAR AC W", CO .4 B �JN E R BOX X�-_IQ-AMI-2404 80A i 240V SEE SI 0 FOR APPROXIMATE LOCATION ENPHASE 10 ENVOY 15A r 20A 20A 5, OA L20 LI -(3)-#6 THWN-2 AND (I) -#a GROUND IN MIN DIA. PVC OR OTHER NEC COMPLIANT CONDUIT BONDING CONNECTION GROUND PATHS PRE A 4, `41IasIFrtI GOOL,q No. 82345 THE NEC GIVES YOU THE CHOICE OF FOUR MiETHODS FOR ENSURING ELECTRICAL 10/07/2022 CONTINUITY AT SERVICE EQUIPMENT, SER)NCr_ '01 44/- RACEWAYS, AND SERVICE CONDUCTOR ENCLOSURES-, TATE OF 4 [250,92(B): R kti I.BONDING JUNIPERS BOND METAL PARTS TO THE SERVICE NEUTRAL CONDUCTOR. THIS REQUIRES A lf'V& � MAIN BONDING JUMPER [250.24(6) AND 250,281, QN4 BECAUSE THE SERVICE NEUTRAL CONDUCTOR PROVIDES THE EFFECTIVE GROUND -FAULT CURRENT PATH TO THE POWER SUPPLY [250 24(C)I, YOU DON T HAVE TO INSTALL AN EQUIPMENT GROUNDING CONDUCTOR WITHIN PVC CONDUIT CONTAINING SERVICE -ENTRANCE CONDUCTORS [250,142(A)(1) AND 352.60 EX 2)- ISS D/REVISED 23HREADED FITTINGS. TERMINATE METAL RACEWAYS TO METAL ENCLOSURES BY THREADED HUBS ON NC OESMP'10n -E ENCLOSURES (IF MADE WRENCHTIGHT). 3THREADLESS FITTINGS. TERMINATE METAL us, row RACEWAYS TO METAL ENCLOSURES BY THREADLESS FITTINGS (IF MADE TIGHT) 4,OTHER LISTED DEVICES. THESE INCLUDE BONDING -TYPE LOCKNUTS, BUSHINGS, WEDGES. OR BUSHINGS WITH BONDING JUMPERS. ELECTRICAL DRAWN BY RDG "4" y� SAMPLE BONDING CONNECTIONS (FOR REFERENCE AM (D-Ego-fPLAN ARRAY AND ROOF PLAN DIMENSIONS AND JOIST ORIENTATIONS TO BE VERIFIED IN FIELD (TYP.) GOOLA xCEN \\,xCEN GEN81�- No.82345 % '13 10/07/2022 Q-5 "�--STATE OF -4 ORVD� q1QN A4 Na -ATE STRUCTURAL PLAN DRAWN BY: RDG m PROVIDE (2) MOUNTS AT ARRAY EDGE UNLESS SHOWN OTHERWISE ON PLAN (TYP.) RAIL CONNECTION AND ANCHOR TO ROOF JOIST PER DETAIL 21S2.0. STAGGER CONNECTIONS. (TYP.) NOTE: ALUMINUM RAILS SHALL BE SUPPORTED BY MORE THAN ONE FOOTING ON BOTH SIDES OF SPLICE. NOTE: REFER TO MODULE INSTALLATION MANUAL FOR CLAMPING LOCATIONS AND REQUIREMENTS, 14" S,& 18-8 BOLT W1 I'SS SERRATED FLANGE NUT J" S.S. 18-8 BOLT W1 J'SS SERRATED FLANGE NUT SUNMODO NANO MOUNT WITH INTEGRATED GASKET ALUMINUM END CLAMP OR MIDCLAMP m PROVIDE IRON UFO CLAMPS ""'Jv CLAM 4'-0" 1/4" MAX. (U.N.O.') 9.5" 1 MAX. RAIL CANT, T_ IRON RIDGE XR10 RAIL (TYP.) 44 0' - SR PANEL -------- TYP. LANDSCAPE MODULE MODULE (TYP.) C IA __j L_____j EXIST. JOIST 24"O.C. (V.I.F.) m —ROOF EDGE OR RIDGE (WHERE OCCURS) EXIST, JOIST �,� ARRAY AND ROOF PART PLAN ALUMINUM RAIL PER PLAN -(2}-J'S.S. LAG BOLT "WI EXISTING ROOFING ,,J"SS FENDER WASHER EXISTING PLYWOOD BOSTIC SEALANT SHEATHING —EXISTING 2X4 (MIN.) ROOF JOIST @24- aa REFER TO GENERAL NOTES ON Cl 0 FOR ADDITIONAL INFORMATION. EXISTING ROOF: SHINGLE ROOF ON PLYWOOD SHEATHING ON 2X4 (MIN.) WOOD JOISTS @24" O.C. MAX NOTIFY E.O.R. IF OTHERWISE. DRILLING INTO STRUCTURAL WOOD MEMBER: Do NOT PENETRATE COMPLETELY THROUGH THE MEMBER WITH PILOT HOLES OR BOLTS. LIMIT BOLT LENGTHS AS REQUIRED, LAG SCREW INSTALLATION GUIDELINES: 1. REFER TO MOUNT MANUFACTURER FOR INSTALLATION AND SEALING GUIDELINES. 2. DETERMINE THE LOCATION OF THE MOUNT ON THE ROOF BY TAPPING THE ROOF AND DRILLING THROUGH THE CENTER OF THE TRUSS W[TH,6" DRILL SIT. FILL EXCESS HOLES WITH SEALANT. 3. MARK MOUNTING HOLES FOR MOUNT ON THE ROOFING / UNDERLAYMENT. MOUNTING HOLES SHOULD BE CENTERED ON THE TRUSSES. 4, DRILL jj`PILOT HOLE, 5, PLACE MOUNT OVER ROOFING / UNDERLAYMENT WITH HOLES IN ROOF. & APPLY SEALANT TO BOTTOM OF MOUNT, APPLY SEALANT TO LAG SCREWS, AND FASTEN MOUNT SECURELY TO TRUSSES WITH LAG SCREW PER DETAIL 7. APPLY ADDITIONAL SEALANT TO TOP OF ASSEMBLY TO BE SURE ALL PENETRATIONS ARE SEALED_ NOTE: MANUFACTURERS' WARRANTIES MAY NOT BE VALID IF RAIL AND MOUNTS ARE PROVIDED BY DIFFERENT MANUFACTURERS. INSTALLER TO ACCEPT RESPONSIBILITY UNLESS APPROVED BY OWNER. PER FLORIDA STATUE 61 G4-15-021, ROOF PENETRATIONS AND FLASHING ARE LIMITED TO AN AREA WITHIN 18'OF EACH PENETRATION. AND SHALL BE PERFORMED IN ACCORDANCE WITH THE NATIONAL ROOFING CONTRACTOR ASSOCIATION ROOFING PRACTICES. Li "4--, < 38 9" In" 0z Moo mi Z Lu MITREX 0 0-00- Lu UJ X N 390 W I < ULT, DESIGN WIND LOAD = 75 PSF ALLOWABLE DESIGN WIND LOAD = 50 PSF 2m NOTE: INSTALL MID CLAMPS BETWEEN MODULES AND END CLAMPS AT THE END OF EACH ROW OF MODULES TYPICAL SOLAR MODULE cil LINE ITEM DESCRIPTION QUANTITY UNIT 1 MITREX 390 30 EA. 2 ENPHASE IQ8+ 30 EA. 3 80A ENPHASE COMBINER I EA. 4 60A FUSED DISCONNECT 1 EA. 7T"TT7/ / -I 5 20A BREAKERS 3 EA. GOPLq 6 IRON RIDGE XR 10 224 L.F. EA. 7 SU"VIODO NA140 MOUNT 95 -Z� Q7 8 IRON RIDGE MD CLAIVPS 46 EA, No. 82345 9 IRON RIDGE END/END CLAMPS 42 EA, 10 GROUND LUGS 10 EA, 10/07/2022 STATE OF 11 NENA 3R JUNCTION BOX 1 EA. BILL OF NATERIALS IS BASED SOLELY ON THE ,40RI y 1\'o DRAWINGS . QUANTMES ARE ESTIWTES (W/ +/-10% OVERESTI(t TION WHERE APPROPRIATE) AND ARE SUBJECT TO CHANGE BASED ON FIELD CONDITIONS. HARDWARE, CLAIVPS, ELECTRICAL WIRING, ETC, ARE NOT INCLUDED IN THIS BILL OF N%TER[ALS. REFER TO THE IS' UiD/REVISED CONIPLETE SET OF DRAWINGS AND CONTACT INSTALLER FOR "c -E��lp­ SATE ANY WATERIALS NOT LISTED ABOVE STRUCTURAL DETAILS 77VIN BY RDO DATE: 46/f77/7,iJi2 S2.0