HomeMy WebLinkAbout22-5461y ? 1 t I11
I
Issue Date: !,
+ •+
Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
O OCCUPANCY BEFOR
µ CON CTOP SIGNATURE
CITY OF ZEPHYRHILLS — BUILDING DEPARTMENT
RIGHT-OF-WAY USE PERMIT
DATE: 12-20-2022 PERMIT #: 4072015 L
No construction under ground or above ground of any facility shall be accomplished on any City Rights of Way without written approval from the City Building
Department. Any application for approval of construction operations on any City owned Rights of Way shall furnish a detailed drawing showing the complete
scope of the proposed work in triplicate to the office of the Building Official for approval prior to the commencement of any work. A copy of this permit is to be
kept readily available at the site of the work at all times.
PARCEL ID #: 34 25 21 0010 05100 0010 CITY ROAD
Permission is hereby granted to Spectrum Sunshine State, LLCof 30432 SR-54 Wesley Chapel FL. 33543
For the construction and maintenance of:
Installation 483'New CATV cable and 1-2" HDPE innerduct by Open Trench method
parallel to road Right of Way.
Subject to the following conditions:
1. The construction and maintenance of such utility shall not interfere with the property and rights of a prior occupant.
2. All work shall be done in keeping with the standards of the City Streets Department and under the supervision of the City Building Official, who
will be notified at least one day prior to commencement of construction.
3. All materials and equipment shall be subject to inspection by the City Building Official.
4, During construction all safety regulations of the Department of Transportation shall be observed and the City shall be relieved of all responsibility
from damage of any nature arising from this permit. Subject to the same terms and conditions, the permit holder may take such safety measures,
including placing and display of caution signs, as it may deem necessary in conduct of construction and maintenance work hereunder. It is the
responsibility of the permittee to ????
5, All private and all City property shall be restored to its original condition as far as practical in the opinion of the City Building Official.
6. All underground crossing installations shall be laid at such depth as may be specified by the City Building Official.
7. The sketch covering the details of this installation shall be made a part of this permit. This permit is granted with the understanding that the
applicant has notified all other utility users in the area covered by the permit and takes full responsibility for any damage incurred by prior
installations as a result of his operations in order that they may safe guard their interests,
8. It is expressly stipulated that this permit is a license for permissive use only and that the placing of facilities upon public property pursuant to this
permit shall not operate to create or to vest any property right in said holder.
9. Whenever the City decides to further exploit the City Rights of Way, any or all said poles, wires, pipes, cables, or other facilities and
appurtenances authorized hereunder, shall be immediately removed from said Rights of Way, or reset or relocated thereon as required by the
City Building Official at the expense of the holder of this permit,
10. The holder shall save and keep the City harmless from any and all damages, claims, or injuries that may occur by reason of the construction,
maintenance, and operation of said facility.
11. The holder shall complete the requested work within days or this permit shall become null and void. In the event the work requested is
not completed upon the expiration date of this permit, the City shall have the right to complete such work and to charge the holder of the permit
for all costs incurred in completed said work.
12. The holder shall post a cash or surety bond with the City Manager in the sum of $ dollars to guarantee performance of the
obligations herein, and to guarantee maintenance of the right-of-way described herein fora periodofone (1) year following completion of the
requested installation. In the event a surety bond is posted, the surety bond shall be made payable to the City and shall obligate the surety to
hold the City harmless in the event the holder of this permit should fail to meet any of its obligations hereunder. The bond shall also indemnify
the City for all court costs and reasonable attorneys fees in the event legal action is required to collect on said bond,
SUBMITTED BY:
(PERMITTEE) Zachan/ Dys (Spectrum)
Signature & Title —Construction Coordinator
Address 30432 SR-54 Wesley Chapel, FL. 33543
Phone # 813-714-2971 Email: zacha Ays(akhartercom
APPROVED BY:
CITY OF ZEPHYRHILLS
Utilities Supervisor Date
Public Works 0A6'--'V' 60,`CZ
Date SC-0 4 � J,(,� 7 r
ZMESHM
HIM
City Manager Date
JOB LOCATION MAP
X PWR WOOD POLE
0
PWR CONCRETE POLE
El
PWR STEEL POLE
X
ST LITE
JOINT USE TRANS
JOINT USE
FIRE HYDRANT
CULVERT
STORM DRAIN
— P_ — W -
REC_ Rl'o- REC-
ROW
EOP
CENTER LINE
POWER
Comm
WATER
SERE R
RECLAIM
GAS
APPLICATION CITY OF ZEPHYRHILLS PERMIT
TO PLACE NEW CONDUIT & CABLE WITHIN CITY RIGHT OF WAY
JOB DESCRIPTION:
6enoral Note5
01 ; �
1, 4 Cat/ Construction within th6l OlAlbh(� Fights of V'Val shall b r- in -ol r-b,
with the I 'ocal juri5didion'5 "Minimum 5tandarJ5''
2, (ke Contractor 5ka,11 notlf_u, Call 5Ai-,,iire and otxer Alliliec, p,er to
cornmercorrorit, of _on5trjc1,
, 91,
115-,- the ' 9,ircctiorol [ioro N.etl od for all )rjvcwaq cro'-35jrop,
4, All open asphalt cats shall l e restored 35 per exhibit F oF rhe
F V0,f , utility accommodation guide,
K �7, All sidewoiH errovai anoli re'pla(_ernort driall be re-,+,orocl 4c)
tine-, Local -1 u r i 5 J i d i on an J F 0',', 5ta ri d aroll 5peri aoz on IcI 0, 5c 2 2
6, kdaorco,,,4ruLion Stab ma:nta;,,, 3 rrinimm ()F8! deararcc parakA to
and cirl—,5iro, all FVDT, r, IcIR-, of Wall,
All aerial construction 5kall martaina minimum of I clearance i).aradel to
and 18 crr)55jr-,q all L-oLx.tq,-x,d Muricipa; 'iooiqlhics of V'Vaul,
8 Must ma main rrinjrn,,),m 2ft, -,eperation between existing udiliec
woair,kor going over or under or paralleling:
9, Phq5lcal hard J LIclinq +,o be u5eJ at all brne-7 in conflict zones
Xo 0rrnjzc o!,arniaooc,
10, Uroleroiround 'Ailhtle5 ha.vo [.,oen plotted From avaj:lclo rocol-j", and
field obormb&5, but are net neco55ariiq exact: rhorofore utility locations
will be verified IGOR, inadvarice, of trenching, p1owino, and borircl
"o fat Lharqcc can be mare ir event of Lod
11. Fes orabjor +ail begin witkjr +,tree > 'Ne612,., after tkc M5-,allafiar,
of ('alclel conduit, Full qr,355 k 5ced and miji(h or 5oalollfno, a5 approved:
12, No open trenches to be left open overnight, 'AoeJ-, to be bol
lic 5afeicj Hazzard)
N"o oKca','aticyn 51r-lad be pormit-.6o vvi_,tlr 10' of' pro�,octcd troc-5
20' f'for l Oak,-,' ) : /_Nuvlj,,q jr,>t4latlol Stall [)e il`cd.jonal bore
beclinino ojt-,Jo of protected radiu5,
14, 1io5c dratvirlc5for porm.t"jr.,q purpose, Aq,
k11 Con5truc& Meth45 and MaXoria!5 vv,t�r F�C)r W -orrp� wi,-Elh , e
.FJ;t,on5 of the %amdard Flans, the rA,3ijarj Spec ;FCC siCr,-; for Foaoll' r::Ago
Constru_,tlor, and the Iiliv,� Ac,,omlrroolahon Manual (11-VA)
65, Al FOf F/W disturbed L.,q thi�, wo-� 4all �e rc5torolo!'to it or,oln-al r-ondtlon
or better a-jol In to appk�wPo 1`✓O� 5pocificalon5 AH a di Farb eo
cq --o-15triction sha be re Ur, oe and Sodded, 'natchlro", ora55 -,qpo,
11, �rq damage caused bq the contractor -,61 be repaired bq the contractor/
SULCAroicto, at his Sde eApenee,
18. Po not place outrigger pad-, or, c,olemalk,
PROJECT NAME: 7431 GALL BLVD, ZEPHYRHILLS, FL COUNTY: PASCO
DATE: 12-20-22 SECTION: 34 TOWNSHIP: 25 RANGE: 21
ENGINEER: ZACHARY DYS DRAWN BY: K.L.
PRISM NUMBER :4072015 1 WORK ORDER #:1901486 SCALE: NONE
TYPE OF PERMIT:CITY T TRACKING #: DRAWING SHEET : I OF 4
PLANVIEW OF CATV UNDERGROUND CONSTRUCTION
w I I w
Note: Maintain minimum
30" from storm structures
I*place sediment de
Q>
2
CLO
60
['>--� pipe
®pipe
17in
Pipe
M14in
Row-
f7'
141n 141n
Pipe pipe
------
141n 14in
6 14in pipe
pipe pipe
pipe
gra
guard r it pipe
a; Ls
guard rail
Eo
Sw
GREEN SLOPE DR
2 C/L— -
6
— - — - — - — - — - —
- — - — - — - — - — - — - —
- — - —
- — -
2�
f-1 4'
27
r-14'
gross
WLEDP
Row
— --
— --
fence
Pole #NT
Pole #NT
Pole #NT
retention area
End point
at existing
dog house
Proposed placement of
483ft Catv Cables & (1) 2" HDPE Innerduct
Open Trench Parallel Minimum 36" depth
Refer to Trench Profile A
APPLICATION CITY OF ZEPHYRHTLLS PERMIT
Spectrumpi,
15
w
S+ N-
TO PLACE NEW CONDUIT & CABLE WITHIN CITY RIGHT OF WAY
JOB DESCRIPTION:
IE
CATV UNDERGROUND CONSTRUCTION
Tie point at I
Pole #2768295
Riser f 0
lI z
0
i CL
PROJECT NAME: 7431 GALL BLVD, ZEPHYRHILLS, FL COUNTY . PASCO
DATE: 12-20-22 SECTION: 34 TOWNSHIP: 25 RANGE: 21
ENGINEER: ZACHARY DYS DRAWN BY: K.L.
PRISM NUMBER 072015 WORK ORDER 4: 1901486 SCALE: I "=50'
TYPE OF PERMIT: CITY TRACKING #: DRAWING SHEET :2 OF 4
PROFILE VIEW OF CATV UNDERGROUND CONSTRUCTION
PROFILE A
TYPICAL CATV TRENCH PARALLEL TO ROAD ROW
GREEN SLOPE DR LOOKING NORTH
Pole #2768295
Row cG, Row Riser
17' Eoo 13' CAL 13' Fop 17'
grade 5O grade
24" ----1------------------------------------ 24"
3O" __J------------------------------------- 3.O"
14'
36" --------- -------------- 36,.
42 ----------- -- 42„
O
f
72" ---------------------------------------- --- 72"
Proposed placement of
483ft Catv Cables & (1) 2" HOPE Innerduct
Open Trench Parallel Minimum 36" depth
APPLICATION CITY OF ZEPHYRHILLS PERMIT PROJECT NAME:7431 GALL BLVD,ZEPHYRHILLS,FL COUNTY:PASCO
TO PLACE NEW CONDUIT&CABLE WITHIN CITY RIGHT'OF WAY DATE:1?-20-22 SECTION:34 TOWNSHIP:25 RANGE:21
Spectrumo, W E ENGINEER:ZACHARY DYS DRAWN BY:K.L.
;rte JOB DESCRIPTION: PRISM NUMBER :4072015 WORK ORDER#:1901486 SCALE:NONE
CATV UNDERGROUND CONSTRUCTION TYPE OF PER IIT:CITY TRACKING#: DRAWING SHEET :3 OF 4
CONSTRUCTION DETAILS
TYPICAL CATV RISER DETAIL
utility pole primary power lines
secondary power lines
STANDARD TRENCH DETAIL secondary power lines//EXISTING GRADE EXISTING GRADE other utility lines
NOTE; 40" min.
TRENCH SHALL BE BACK FILLED INurTs Nor TO
TO A MINIMUM DENSElY CEED 5OF 98%A2' AND S
36" 12" min. catv lines
o o DETERMINED BY AASHTO T-180 ---
36" PAIN. 38 MIN.
o z 12" 2" schedule 40 u guard
< ¢ 'x PROPOSED CABLE/HDPE/SCHFDUCE 40 CONDUIT dawn gay /steel riser u—guard
o o w z° s° g 18' min.
" cats riser
grade
LOUR QUADRANT TO BE SHAPED
HAND PLACED TO RECEIVE CATV CABLES AND
SELECT MATERIAL TO RECEIVE HOPE J SCHED.40 CONDUIT
IN 6"LIFTS 36" min.L
APPLICATION CITY OF ZEPIIYRHILLS PERMIT PROJECT NAME:7431 GALL BLVD,ZEPHYRHILLS,FL COUNTY:PASCO
® TO PLACE NEW CONDUIT&CABLE WITHIN CITY RIGHT OF WAY S p e ct ru flDATE:12-20-22 SECTION:34 TOWNSHIP:25 RANGE:21
w ENGINEER:ZACHARY DYS DRAWN BY:K.L.
JOB DESCRIPTION: PRISM NUMBER :4072015 WORK ORDER#:1901486 SCALE:NONE
it S
CATV UNDERGROUND CONSTRUCTION TYPE OF PERMIT:CITY TRACKING 8: DRAWING SHEET :4 OF 4
I. This Index applies to Toro -Lane, Two -Way
and Multi}ane Roadways, including Medians
of dividcd roadviays, with work on the
shoulder.
2. L lapel Length
X = Work Zone Sign Spacing
B = Buffer Length
See Index 102-600 far "L`, X", "B", and
charx.etirirg device spacing values.
3 Where work actrvr!ies are between 2 and
15' from the edge of traveled way, the
Engincor r-ay or rt signs ana channelizing
devices for work operations 60 minutes
or less.
4, When four or more work vehicles enter the
through traffic lanes in a one hour period
(excluding establishing and terminating the
work a'ea), use a flagger or lane closure
to ,accommodate work vehicle inyrress and
egress.
5. For work less than 2` from the traveled way
and work zero speed is greater than 45 MPH,
use a tone closure.
6. The "Speeding Fines Doubled When Workers
Present" signs (MOT-13-06) and 'End Road
Work" Signs (G20-2) along with the
associated work zone sign spacing
distances may be omitted when the
work operation is in place for 24
hours or less.
7. Temporary pavement markings may be
omitted when the work operation is in
place for 3 days or less.
S. Omit "Shoulder Closed` signs (W21-5a) along
with associated work zone sign sportily
distances for work on the tnedian.
9. When there is no paved shoulder, the
"Worker" sign t+W21-1) may be, used instead
of the "Shoulder Closed" sign (W21-5a).
SYMBOLS:
® Work area
11 Channelizing Device (See Index 102-600)
Vlork Zone Sign
Lane identification and Direction of Traffic
MOT -13-06
C120-i F
(See Plote 6)
G20-2
(See Note fi%
5 uiK FINLS
ROAD
END
��N ,voes
P
WORK
AHEAD
�
ROAD WORK
.BENT'
6"' White (See Nate 7) —qj
10, Nll"i -- i
®z
X � L/3 B
X
_ �.
r..,._..
\ ROAD
(
( SPERM ENES
4 WORK j
DOU31LEDA1GNT
( 11HEN haRBERS
SHOULDER
CLOSED
_
E N D
ROAD N)ORKI
AHEAD
PRca4rF
i
[4OF 13-06
\
G20-2
N2D...IF
(Soo (Vote 6)
W2 1-Sa
{See Note G}
TWO-LANEROADWAY
SHOULDER WORK LESS THAN 2' FROM THE TRAVELED W
WITH WORK ZONE SPEED OF 45 MPH OR LESS I
G20-2
(See Note 6)
END
%. ROAD WORK
r
f -
10
x D x a X D
- ^-
R
WORK , /SZ��DE\R\
AHEAD CLOSED .ROAD WORK'::
v
\ G20 2
V120-IF V121-5a (See Note 6)
ROADWAY
SHOULDER t AND FROM +.
W20-1F
D
WORK y
'AHEAD`,,/
LAST 1Oj
DESCRIPTION: I-Y 2022 23 I INDEX SHEET
REVISION , r TWO-LANE AND MULTILANE,WORK CAN SHOULDER
111101121 � � � STANDARD PLAINS�102-602� 1 of 2
6 White(See Note 7)
Median i�
10' Min.
�w I
I X / X /3 8 X
ROAD H
s 1 RieHr EtiD
`� R\ /' P 1,20.-2
MOT-a3-06 ��
•V120-IF (See Note 6) W21-5a (See Note 6)
(See Note 8)
MULTILANE ROADWAY .-------- -......-- ..-------__.--
SHOULDER WORK LESS THAN 2' FROM THE TRAVELED WAY
WITH WORK ZONE SPEED OF 45 MPH OR LESS
Median
X y U3 Lam/ 7
SYMBOLS: �
� l1A Sock Area ROAD
W4RK �' SHOULDERS A� END
# ClranreHzing Device(See Index 102-600} \AHEAD ° ct�ss� ROAD WORKflt '
G20-2
Work Zone Si go V120-IF P21-Se (See Note 6)
(See Note 8)
Lame Ideirtiflcation and Direction of traffic
MULTILANE ROADWAY
SHOULDER WORK BETWEEN 2' AND 15' FROM THE TRAVELED WAY
LAST DESCRIPTION:
FY 2022-23 INDEX SHEET
REVIsroN O' TWO-LANE AND MULTILANE, WORK ON SHOULDER
11101120 STANDARD PLANS 1012-602 2 of 2