Loading...
HomeMy WebLinkAbout22-5473Address: 4600 W Cypress St 200 TAMPA, FL 33607 Phone: (813) 574-5700 SIF 1 percent Fee Address Fee Plumbing Valuation Fee Driveway Fee Transportation Impact Fee - City Electrical Permit Fee Fire Wall/Smoke Wall Inspection Mechanical Plan Review Fee Public Safety Impact Fee -Police Buildino Plan Review Fee City of Zephyrhills 5335 Eighth Street Zephyrhills, FL 33542 BNR-00547 Phone: (813) 780-0020 Issue Date: 12 Fax: (813) 780-0021 Class of Work: Townhome Building Valuation: $255,720.00 Electrical Valuation: $38,368,00 Mechanical Valuation: $17,900.40 Plumbing Valuation: $25,572.00 Total Valuation: $337,550.40 Total Fees: $13,866,90 Amount Paid: $13,866.90 Date Paid: 12/2812022 4:08:01 PM 100111=3=1 UWE "7 "' <) $3153 Transportation Impact Fee $3,445.20 $30.00 Sewer Connection Residential Fee $2,090,00 $0.00 Park Impact Fee - Single Family/Townhome $769.56 $45.00 Plumbing Permit Fee $167.86 $34.80 Water Connection Residential Fee $1,0%00 $732.71 Mechanical Permit Fee $129.50 $231.79 Building Permit Fee $1,318.60 $15.00 Electrical Plan Review Fee $0.00 $0.00 School Impact Fee - Single Family $3,35100 $254,00 Public Safety Impact Fee -Admin $26.35 $180.00 111111plip 11111pI 11 11 111 1 111 1 11111111 A T471-MM717,71Tn"PTIM, # Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. RT WCTORSIGNATUREM I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PE E "Y' 813-780-0020 City Of Zephyrhills Permit Application Fax-813-780-0021 Building Department Gate Received phone Contact for Permiftin 908 770�_7763'Owner"sName CAL HEARTHSTONE LOT OPTION POOL 03 L P Owner Phone Number 4.5700 Owner's Address 23975 Park Sorrento, Ste. 220, Calabasas, CA 91302 Owner phone Number Fee Simple Titleholder Name I N/A Owner phone Number E_W Fee Simple Titleholder Address N/A JOB ADDRESSQZF nipple POrld LOOP LOT # SUBDIVISION Abbott Square PARCEL ID# QZF®2�®21 0140-001 Q{�p t� (OBTAINED FROM PROPERTY TAX NOTICE) WORT( PROPOSED NEW CONSTR F—] PADD/ALT SIGN DEMOLISH INSTALL REPAIR PROPOSED USE 0 SFR COMM OTHER TYPE OF CONSTRUCTION 10BLOCK FRAME STEEL DESCRIPTION OF WORK Multi -family 1 Screen Enclosure !Fence IJ/R 5F BUILDING SIZE 2131 SO FOOTAGE 1 HEIGHT � BUILDING $ 255720� VALUATION OF TOTAL CONSTRUCTION ELECTRICAL $ 33358 PLUMBING 171 25572 MECHANICAL $ 17900.4 GAS IZI ROOFING FINISHED FLOOR ELEVATIONS[::= ® PROGRESS ENERGY W.R.E.C. AMP SERVICE VALUATION OF MECHANICAL INSTALLATION SPECIALTY = OTHER FLOOD ZONE AREA YES Do BUILDER COMPANY Lennar liornes, LLC SIGNATURE REGISTERED Y / N FEE CURREN Y / N Address 4301 Boy$mp cout Blvd Suite 600 Taa, FL 33607 License # tCrC1518166 s ELECTRICIAN COMPANY Edmon;son Electric, Inc. �' SIGNATURE REGISTERED Y / N FEE CURREN Y / N AddressLicense # E130054QS PLUMBER COMPANY Bayonet Plumbing, Heating & AG, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y I N Address License # OF04299$ �mm� MECHANICAL COMPANY bayonet Plumbing, Heating & AC, Inc SIGNATURE REGISTERED Y / N FEE CURREN Y / N Address License # CAC053062 OTHER COMPANY C sterling Quality Roofing, Inc SIGNATURE REGISTERED Y / N FEE CURREN Y / N Address � License # CC0057991 11111tIt11E�it1 Illlit�lf�lll11i111E11�/�11����III�IIIIIIIWilI111IE! RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms, R-O-W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. "*"`PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (A/C upgrades over $7500) — Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage) Driveways -Not over Counter if on public roadways..needs ROW 91 NIA ilk Ito, OWNER OR AGENT Subscribed and sworn ro(5, affirmed} before me this 1 912/2022 by Christopher Smith Who istare personally known to me or as identification. Notary Public Commission No.—GG 296057 Stephanie Farmer Name DOM Fatcuoy '115, 2023 Now TW TMY F* %MM CONTRACTOR____gg;����. Subscribed and sworn to (or affirmed) before me this 912i2022 by _ Christopher Smith Who istare personally known to me or has/have produced as identification. Commission No. GG296057 Stephanie Farmer .................... . . . . . . . . . . . . . . . . . . . . . . .......... Notary Public DESCRIPTION: LOTS 65-68, BLOCK 1, ABBOTT SQUARE PHASE IA, SITE PLAN SEC. 11, TWP. 25 S, RNG 21 E. '.. ACCORDING TO THE PLAT THEREOF, RECORDED IN PLAT BOOT( 89, PASCO COUNTY, FLORIDA '.. PAGE(S)28-35, OF THE PUBLIC RECORDS OF PASCO COUNTY, (NOTA SURVEY) FLORIDA. (ABBOTT SQUARE) _ CURVE DATA (P) _ _ CURVE T RAD!US ARC LENGTH CHORD LENGTH CHORD BEARING�DELTAANGL6� C28 320.00" 29.83' 29.82' S 34'02'43" '.. C29 320.00' 20.01' 20.01' S 38°30'27" E 3°3S'O0 C30 320.00' 20:01' 20.01' S 42'05'27" E �� 3°3a'00" C31 320.00' 29.83' 29.82' S 46'33' 10" E 5°20'28" This SITE PLAN Prepared for and Certified To: Scale. 1 " - 20' — Lennar Homes — \ ALL ELEVATIONS REFERENCED TO NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 88) PROPOSED ELEVATIONS AND GRADING SHOWN HEREON ARE TAKEN FORM THE ' ENGINEERING PLANS OF "ABBOTT SQUARE RESIDENTIAL PREPARED BY "WRA" PROVIDED BY CLIENT TP LOT 64 rtyr C BLOCK 1 `�ti F. 9g ql. �P\ s \ o \C 'S aF� Z i r� pay/ '# 9�, •. CO r�Cy 54s.a 9 IN GE iA h� r3 rd Cp O ,�`L v of pub acP'T� rd ti C = 2` OAK * 10.00' PUBLIC UTILITY EASEMENT rr 6, O,* <sa, l �3 ,✓ ` LEGEND: ask ,.--%""-,I► PROPOSED DRAINAGE FLOW `y,^P ra A, S.-�, rr � (00,00) = PROPOSED GRADE 'O Cyc- FrA rt+� 1 �'�- Or` E-00.00 = EXISTING GRADE s"2�-{pY,,t..r�,.s 'rr� o00 Y_ 1w`. <9 C?ry 3 q r', /.o .SOS 100 971 NOTES: ��� �' ��. ��. � LOT 69 LOT GRADING TYPE =B �C ,�� BLOCK i F2 q PROPOSED PAD ELEVATION = 101.20` FRONT SET BACK = 20' NIP r'2 �4 SIDE SET BACK =T5' 0K' pR = 10965 SIDE SET BACK (CORNER LOT) _'s �'or �aa ��y LOT SO. FT', LIVING AREA �_ 2Sb6 SO_ FT. REAR SETBACK = 15' >4 ENTRY =' 220 _SO. FT. / GARAGE _ �QS8 SC).FT. PROPOSED: COVERED LANAI = 374 SO. FT, MINIMUM FLOOR ELEVATIONS: / 100361 PATIO NA SO_ FT, LIVING AREA: 101.87` POOL AREA - NA SO. FT, GARAGE AREA: CONC. DRIVE FT. ELEVATIONS REFERENCED TO A/C & CONC PAD =_36 Sty. FT, NORTH RMERICAN VERTICAL SIDEWALK = 540 SQ. FT. SIDE YARD SWALE = Na SO. FT, DATUMOF 1988 CONSERVATION AREA =-,_NA SCr FT. APPARENT FLOOD HAZARD ZONE- "X' COMMUNITY NO. 120235 LOT OCCUPIED = 53 te, SURVEY ABBREVATiONS (MAP NUMBER 12101C-0289-F) EFFECTIVE DATE: 09/26/2014 AREA TO IRRIGATE = 47 % A) -ARC LENGTH CD-OFFED I.NVs INV2 PC=POINT Or CURVE RI -RECORD LEGEND AiC AiRCONDCTONER D DgAiNAG EASEMENT LB-LICENS BUANESS PCC FOIN Or COMPOUND CURVE i VINYt EENCE AFALUMINUNFENC-� RS- RANGE Y XYl pi ( 1 FL OR EDGE OF VAT, LE =LANDSCAP EFlSr'.MENT PC, ERMANFN`*CONT20.. POINT IvRS eRPI ROADSPI'CE h i f++z CONC "�""'tWl �"'•' 9 E-F#ASF Fl6OD ELEVATION FO EDGE OF PAVENEN' ,.FEy LOWER!'-OORUEVA..ON PIE EQUIPMENT j+W RIGHT pF WAY BM -__MARK �SM' =EASEMENT LS-LICENS SURVEYOR G=PACE ,. WOOD FENCE C- Ct,RU<EC=-SECTION FJC eNC` CORNER IM)-M MEASURED N- PONTONT OF INTERSECTION SN&D-� S`_ r NAit AND DISK :, ^ASI'NAIT ^"-`- ` "•� ICICCAL(.IJt'FD OD SOUND CONCRETE ws- MIT RED END SECTION PK-PARKER KAI, ON "PISI83 CENT`cRUVE MONUMENT NCF-NOCORNERFOUND k IROCPTYLtNE OR Sri 112' IRON ROD Lao III CIINNLiNKHNC}: CL -CYAN Nk FEN c ul-, To ND IRON PIPE O,A-OVERALL POE} PONr OF BEGINNING TISM- TEMPORANY BENCT! MARK �mBRiCK CM =CON' UGATE)M�TAt. 1 Ip�.,�-OUN€J IRON,ROD OHW-OVERHEAD lV1RE(S POC- Pp N� O=COMMFNCTMENT 108-TOIIQPBANK COL CCOLUMN N&O-FOUND NAIL &DiSK O.R. -OFFICIAL RECORDS POL• CSNI ON,. LINE rW-TOWNSHP AtLPODAIM PENCE. CONC a ON CR`-TE POP =FOUND OPEN )PPE ILI -PLA'( PRC = POINT OF REVERSE CURVE U. C/S=CONCRErE SEAS UTILITYFASE!.t,ONi-COVkRED _A ,^ ESi= CLEAR SIGHT TRIANGLE Pp'-C)UND PINCHED PIPE PB=PLAT BOOK PRMxPc'RMANEN'REFERENCE MOhJMLNT VE—VINe_rENCE JOB #5714 SURVEYOR'S NOTES: SURVEYOR'S CEITT I4 ICATE 1708 Water Oak Drive Date of Site Plarr6-20-22 t') Current title information on the subject property had not been Thls certifies that k�j GjUoj4ie hereon described Tarpon Springs. Florida furnished to Initial Point Land Surveying, LLC, at the time of this property was n¢$ 14 crvision and Phone: (727)-831-t 990 DWGAS-L65-68-BI-SITE SITE PLAN meetsth,*1D tv,'actice for FloridaPLS7123 gmaiLrom 2.) This sketch was prepared without the benefit of a title search. uneyfl `. d of Ln.¢t,Bdi 8t83No instruments of record reflecting ownership, easements or n St (i (iFile rights -of -way were furnished to the undersigned unless othdrwlse r �C.,„c,,,,',1,DrawnbyDJBshown hereon. pursuiTnt to72 J.' , I _ t Ha le S.) Roads, walks, and other similar items shown hereon were taken St to; r%"'t ^t YS CD, Checked by.JH from engineering plans and are subject to survey. p L�G.G V 4J This SITE PLAN does not reflect nor de ermine ownership. ' per} q 1 OI T` REVISIONS 'tL'ddF 6.) This SITE PLAN is subject to matters shown on the Plat of ♦� sh I�IDA � � - ' Ake "ABBOTT SQUARE PHASE IN —- ----°"-- Jeff M. H 6.) Dimensions shown hereon are in feet and decimal portions �} !� thereof. ELORIDAP �V�i�RAND 'J 7.) Contractor and owner are to verify all setbacks, building MAPPER NO. LSIdG�p dimensions, and layout shown hereon prior to any construction, NOT VALID WITHOUT THE ORIGINAL and immediately advise Initial Point Land Surveying, LLC. of any SIGNATURE AND SEAL OF A FLORIDA deviation from information shown hereon. Failure to do so will be LICENSED SURVEYOR AND MAPPER Initial Point Land Surveying, LLC. at users sole risk. Permit No, ` Efate Permitted Builder Name/Owner Name Control County Parcel No. tZ a&Address/Location Classification/Ty pe of use TRANSPORTATION IMPACT FEE Rate: Sq, Ft unit: Exempt 0 Yes No Flow Determined Impact Fee Amount Zone No. TAZ. SCHOOL IMPACT FEE Account (056) Single -Family Detached (douse Amount $ (057) Mobile Home (058) Other Residential (123) Collection Fee Exempt ED yes = No How Determined_ PARRS AND RECREATION FEE Land Account nand Credit Land Total Recreation Account Recreation Credit Recreation Total Zone Total Amount $' Exempt =Yes = No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt IDYes No How Determined Total Amount RESOURCE FEE ERU NM BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY EM M General Notes A. CONCRETE & FOUNDATION DESIGN: 1. ALL CONCRETE GRADE BEAMS AND FOOTINGS SHALL BE 3000 PSI MINIMUM_ 2. ALI, CONCRETE FILLED SUPPORTED SLABS SHALL BE 2500 PSI MINIMUM, 3 1/2" NOMINAL THICKNESS. 3. 3000 PSI FIBERMESH 3/4" PER CUBIC YARD MIN. MEETING APPROPRIATE ACI AND ASTM REQUIREMENTS MAY BE USED IN LIEU OF WELDED WIRE MESH 4, ALL SLABS ON GRADE SHALL BE 4" THICK WITH FIBERMESH. TERMITE TREATMENT OF SOIL BENEATH SLAB IS NOT REQUIRED IF SLAB DOES NOT ABUT A WOOD FRAME STRUCTURE. NO WOOD FRAME STRUCTURE MAY BE BUILT ADJACENT TO OR ON TOP OF A SLAB WITHOUT TREATING THE SOIL FOR WOOD DESTROYING ORGANISMS. 5. ALL REINFORCING SHALL CONFORM TO ASTM A615, BE GRADE 60 (60 KSI MIN.) DEFORMED BARS, #3 BARS MAY BE GRADE 40 6. ALL OVER POUR CONCRETE FILLED SUPPORTED TED SLABS SHALL BE 3000 PSI MIN.. 2" MrNIMUM, THICKNESS. 7, SOIL BEARING PRESSURE SHALL BE A MINIMUM OF 1500 PSF. 8. THE CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING: OPC (PORTLAND CEMENT TYPE L- ASTM C 150). AGGREGATES - 46 STONE, ASTM C 33 SIZE NO. 67 LESS THAN 3/4". AIR ENTRAINING +/- 1% - ASTM C 260. WATER REDUCING AGENT - ASTM C 494. CLEAN POTABLE WATER, OTHER ADMIXTURES SHALL NOT BE PERMITTED, 9, METAL WELDED WIRE SHALL CONFORM TO ASTM A 185, 10. PREPARE & PLACE CONCRETE ACCORDING TO AMERICAN CONCRETE INSTITUTE MANUAL STANDARD PRACTICE, PART I, 2, & 3 ALONG WITH HOT WEATHER CONDITIONS RECOMMENDATIONS, 11. IF UTILIZING EXISTING CONCRETE FOR FOUNDATION, CONCRETE SHALL BE A MINIMUM OF 4" IN THICKNESS, VISIBLY FREE OF ANY STRUCTURAL EXCESSIVE CRACKING, SPALLING OR OTHER DETERIORATION. B.MASONRY: 1. CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR, 2.ALL MORTAR SHALL BE OF TYPE M OR S. 3.ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 3/8". 4.PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS 5'-0" IN HEIGHT. C. ALUMINUM: I. ALL STRUCTURAL ALUMINUM SHALL CONFORM TO THE MINIMUM REQUIREMENTS OF 6005-T5 FOR ALLOY WITH A MINIMUM THICKNESS OF 0.040" FOR SUPPORTING MEMBERS. 2. WHERE KICK PLATES ARE USED A MINIMUM THICKNESS OF 0.024" SHALL APPLY. 3. STRUCTURAL ALUMINUM DESIGN CONFORMS TO "PART I -A - SPECIFICATIONS FOR ALUMINUM STRUCTURES - ALLOWABLE STRESS DESIGN" OR "PART I-B - SPECIFICATIONS FOR ALUMINUM STRUCTURES - BUILDING LOAD AND RESISTANCE FACTOR DESIGN' OF THE CURRENT ALUMINUM DESIGN MANUAL PREPARED BY THE ALUMINUM ASSOCIATION, INC.WASHINGTON D.C. THE FLORIDA BUILDING CODE, 7TH EDITION ( CHAPTER 16 STRUCTURAL DESIGN & CHAPTER 20 ALUMINUM). 4. WHERE ALUMINUM COMES INTO CONTACT WITH STEEL, OR PRESSURE TREATED LUMBER PROVIDE DIELECTRIC SEPARATION. 5. ALUMINUM MEMBERS SHALL BE STITCHED WITH NO LESS THAN #10 SMS 6" FROM THE ENDS AND 12" ON CENTER, IF USING #12 SPACING MAY BE 24" ON CENTER. 6. VINYL AND ACRYLIC PANELS SHALL BE REMOVABLE. THEY SHALL BE IDENTIFIED WITH A DECAL ESSENTIALLY STATING "REMOVABLE PANEL SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 MPH". DECAL SHALL BE PLACED SO IT IS VISIBLE WHEN PANEL IS INSTALLED. D. FASTENERS: i, ALL LAG BOLTS SHALL CONFORM TO STAINLESS STEEL TYPE 300 18-8, WITH STANDARD FLAT WASHER UNLESS MANUFACTURER GALVANIZES BOLTS SPECIFIES FOR USE WITH ACQ PRESSURE TREATED WOOD, 2. HEX BOLTS HAS TO BE ASTM A 325, PLATED WITH STANDARD FLAT WASHERS AND NUTS. 3. ALL CONCRETE SCREWS SHALL BE, SIMPSON, HILTI, RAWL, TAPCON, REDHEAD, DYNABOLT, OR APPROVED EQUAL. 4, ALL METAL TIES AND ASSOCIATED ACCESSORIES SHALL BE HOT DIPPED GALVANIZED. 5. ALL LAG BOLTS SHALL HAVE A MINIMUM EMBEDMENT OF 8X BOLT DIAMETER INTO STRUCTURAL FRAMING (G=,42 MIN,). 6. LAG BOLTS AND SCREWS INTO WOOD FRAMING SHALL BE PROVIDED WITH PILOT HOLES HAVING A DIAMETER NOT GREATER THAN 70 PERCENT OF THE THREAD DIAMETER OF THE BOLT OR SCREW, ALL LAG BOLTS AND SCREWS SHALL BE INSERTED IN PILOT HOLES BY TURNING AND UNDER NO CIRCUMSTANCES BY DRIVING WITH A HAMMER, T ALL EXPANSION ANCHORS SHALL BE DESIGNED IN ACCORDANCE WITH THE SPECIFIC MANUFACTURER'S REQUIREMENTS AND ALLOWABLE LOADS AND SHALL ONLY BE APPLIED IN CONDITIONS ACCEPTABLE TO MANUFACTURER. FASTENERS SHALL BE A MINIMUM OF SAE GRADE #5 OR BETTER ZINC PLATED. 8, ALL FASTENERS CONNECTING ALUMINUM COMPONENTS OR PRESSURE TREATED LUMBER ARE STAINLESS STEEL TYPE 300 18-8, UNLESS MANUFACTURER GALVANIZED BOLTS SPECIFIES FOR USE WITH ACQ PRESSURE TREATED WOOD, OR OTHERWISE NOTED ON PLANS. 9. ALL FASTENERS SHALL COMPLY WITH ASTM A153.. 10, ALL CONNECTORS SHALL COMPLY WITH ASTM A653 CLASS G-185, 11. FOR SMS, THE MINIMUM CENTER -TO -CENTER SPACING SHALL BE 3/4" AND MINIMUM CENTER -TO -EDGE SHALL BE 1/2" UNLESS NOTED OTHER WISE, E. REFERENCE STANDARDS: ASTM E 119 ASTM E 1300 ASCE 7 -16 AA ASM35, AND SPEC. FOR ALUMINUM PART 1-A & 1-B ASTM C94 ASTM C150 ASTM C33 ASTM C260 ASTM C494 ASTM A615 ASTM A1B5 FLORIDA BUILDING CODE (CHAPTERS 16,20 AND 23) 7TH EDITION CURRENT ALUMINUM DESIGN MANUAL F. ABBREVIATIONS: THE FOLLOWING LIST OF ABBREVIATIONS IS NOT INTENDED TO REPRESENT ALL THOSE USED ON THESE DRAWINGS, BUT TO SUPPLEMENT THE MORE COMMON ABBREVIATIONS. L TYP --TYPICAL 2. SIM -- SIMILAR 3. DON -- UNLESS OTHERWISE NOTED 4, CONT--CONTINUOUS 5, VIE --VERIFY IN FIELD G. RESPONSIBILITY: 1. ALL SITE WORK SHALL BE PERFORMED BY A LICENSED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDINANCES, ETC. 2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND DETAILS, NOTIFYING ENGINEER OF ANY DISCREPANCIES BETWEEN DRAWINGS, FABRICATED ITEMS, OR ACTUAL FIELD CONDITIONS. 3. THESE DRAWINGS REPRESENT THE ACCEPTABILITY OF THE 'SUNROOM' ROOM ADDITION ELEMENTS AS PROVIDED BY THE CONTRACTOR, 4, ALL DETAILS ON THESE DRAWINGS ARE ENGINEERED BASED ON INFORMATION PROVIDED BY THE CONTRACTOR AND MANUFACTURER. 5. ANY DETAILS NOT SHOWN ARE TO BE ENGINEERED BY LICENSED P.E. IN ACCORDANCE WITH STANDARD ENGINEERING PRACTICES, H. MISCELLANEOUS: 1. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME WITHOUT A MANUFACTURER'S HOST BEAM. IF NO HOST BEAM IS PRESENT A SEPARATE 4TH WALL SUPPORT SYSTEM SHALL BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. Z. IF ENCLOSURE CONTAINS A SWIMMING POOL OR SPA, THE ENCLOSURE SHALL COMPLY WITH RESIDENTIAL SWIMMING BARRIER REQUIREMENTS OF THE FBC 7TH EDITION R 4501A7.1 IN ITS ENTIRETY. 3. DOOR LOCATIONS MAY BE DETERMINED IN THE FIELD BY CONTRACTOR 4. IF PAVERS ARE UNDER ALUMINUM MEMBERS THEY SHALL HAVE EPDXY ADHESIVE TO CONCRETE OR IF USING GROUT, ENSURE BONDING AGENT IS USED FIRST. 5, SCREENING MATERIAL SHALL BE 18X1.4X0.013 OR EQUIVALENT DENSITY SCREEN MESH ONLY UNLESS NOTED OTHERWISE. 6. EMERGENCY ESCAPE & RESCUE OPENING PER FBC R310.1 H BY CONTRACTOR & BUILDING OFFICIAL SHALL BE VERIFIED ALL z > �. �O3 a 7. ENCLOSED? ADDITIONS TO MANUFACTURED HOMES SHALL NOT L � �1�f,�, ,� T�f V �s� � PR �' CHANGE THE FACILITIES FOR EGRESS PER HUD 328 }.105, (a) a �� I ;) '. i"x�F, cw$ �,.L) fir. e. .aUs ,$,V ((EX}}I((T THROUGH a 2 iv , SO THAT THE DISTANCE TO EXIT DIRECTLY t Il 1i I ' w B Wit, I t �v"Iff-CODE OUTSIDE FROM ALL BEDROOMS IS LESS THAN 35', AND, SO THAT s TWO EXITS DIRECTLY OUTSIDE ARE STILL MAINTAINED. A CARPORT I , "M ) T 7 4t I i f OR SCREEN ROOM SHALL BE CONSIDERED AS OUTSIDE, NON -HABITABLE DI � NC ,. 1I SUNROOMS OR HABITABLE LIVING SPACE MAY BE ADDED WHERE AN EXITp DOOR WAS LOCATED AS LONG AS A NEW EXIT DOOR IS ADDED AND MEETS THE REQUIREMENTS OF HUD 3280,105. CARPORT, SHED, WOOD LANDING, CONCRETE, AND STEPS DESIGN DATA: L ULTIMATE DESIGN WIND SPEED Vult, (3 SECOND GUST): 130 MPH NOMINAL DESIGN WIND SPEED Vasd: 101 MPH 2. RISK CATEGORY: 1 3. WIND EXPOSURE: B 4. INTERNAL COEFFICIENT: SHED (ENCLOSED STRUCTURE): +/- 0.18 CARPORT (OPEN STRUCTURE): 0,0 5. WIND LOADS: FACTOR APPLIED TO WIND LOADS FOR ALLOWABLE STRESS DESIGN: 0.6 SOLID ROOF (MWFRS): 20 PSF COMPONENT & CLADDING PRESSURES: ROOF ZONE 1: 12.4/-48.4 PSF, ZONE 2: 114/-63.9 PSF, ZONE 3: 12,4/-87.1 PSF WALLS ZONE 4: 30A/-33,0 PSF, ZONE 5; 30.4/-40.7 PSF 6. FOUNDATIONS PER "A" OF GENERAL NOTES AND SITE SPECIFIC DETAIL T SOLID ROOF TYPE: 3"X12" ALUM. PANS, FL 169SZ OR EQUIV, FOLLOW SECTIONS 2 x 2:--------------------------------------2" x 2" x 0,044„ 3 x 2:-------------------------------------3„ x 2" x 0.050" 2 x 3:---------------------------------------2" x 3" x 0.050" 2 x 3:--------------------------------------2" x 3" x 0,070' 2 x 4:---------------------------------------2" x 4" x 0.050„ 2 x S:---------------------------------------2" x 5" x 0.050„ 3 x 3:---------------------------------------3 x 3" x 0,072" 3 x 3:---------------------------------------3 x 3" x 0.093" 3 x 3:---------------------------------------3 x 3" x 0.125" 4 x 4:---------------------------------------4 x 4" x 0.125„ OPEN BACK SECTIONS 1 x 2:------------------------------------1" x 2" x 0.040' 1 x 3:----------------------------------------1" x 3" x 0.045" M 2 x 2 Snap: ---------------------------------- 2" x 2" x 0.045" 2 x 3 Snap:---------------------------------2" x 3" x 0.050" 2 x 4 Snap:--------------------------------- 2" x 4" x 0.045" 2 x 4 SMB:---------------------- 2" x 4" x 0.044" x 0.100" 2 x 5 SMB:---------------------- 2" x 5" x 0.050" x 0.118" 2 x 6 SMB:---------------------- 2" x 6" x 0.050" x 0.120" 2 x 7 SMB:---------------------- 2" x 7" x 0.057" x 0,120" 2 x 8 SMB:---------------------- 2" x 8" x 0.072" x 0.224" 2 x 9 SMB:---------------------- 2" x 9" x 0.072" x 0.224" 2 x 10 SMB:------------------- 2" x 10" x 0.092" x 0,374„ R Leh -ate MAIN n?e ,' � L O PLAN Eg q. R I' INDEX: GENERAL S-2 PLANS AND ELEVATIONS ELEVATIONSS-3 PLANS AND S-4 PLANS AND ELEVATIONS S-7 WOOD LANDING I HEREBY CERTIFY THAT I HAVE REVIEWED T141S PLAN A FAIMP IT jO BE IN COMPLIAN SCE RUIPy D FBC 7TH EDITk@ill'' q%-%L AND EXI hyG A it a PROFESSIONAL ENGINEER SEAL ENGINEER OF RECORD David W. Smith P.E. FLORIDA LICENSE NUMBER: 53608 Thomas L. Hanson P.E. FLORIDA LICENSE NUMBER: 38654 Ian J. Faster P.E. FLORIDA LICENSE NUMBER: 93654 Joel Falardeau P.E. Erik Stuart P.E. FLORIDA LICENSE NUMBER: 77605 FBC Plans & Engineering Services, Inc. 5344 9th St. Zephyrhills, FL 33542 Phone:(813)838-0735 Email: erb@Ibcplans.com Website: www.fbcplans.com C.O.A. - #29054 I DATE: 12/01/2022 1 # JOB # 22 1118 346 JOB NAME & ADDRESS: COLON GRAND HORIZON: LOT 95 37624 LANDIS AVE. ZEPHYRHILLS, FL. 33541 CONTRACTOR: B & H CONSTRUCTION GENERALNOTES 58, MANUFACTURED HOME PROPOSED COMPOSITE LANDING W/ RAILING El PROPOSED 4'X TX 4" CONCRETE PAD FOR LANDING AND STEPS Lu 12' X Uj 1- 4' z tJ PROPOSED CONCRETE LANDING 61 AND STEPS W/ RAILING PROPOSED PROPOSED CONCRETE STEPS 6"x 6„W/ RAILING I LINEAL FOOTER FACTORY PORCH PROPOSED PROPOSED CARPORT PAVERS PROPOSED CARPORT PAVERS 4" CONCRETE PAD FOR LANDING AND STEPS PROPOSED 12" X 12' LINEAL FOOTER FOR CARPORT 2" ABOVE ADJACENT SLABS GRADE CONCRETE BELOW GRADE D=MAD kz) R:�D CONT., "12 25'MIN. OVERLAP ALL JOINTS, ON TYPE I] MONOLITHIC SLAB 3" HIGH CHAIRS MODERATE SLOPE FOOTING SLOPE: 2":12'- 3`12" TYPE 11 MONOLITHIC SLAB / FOOTING FOUNDATION PLAN GRADE ifl 6" X 6" LINEAL FOOTER PROPOSED DRIVEWAY PAVERS Isr" ��ffi jyjAMMOWMIM-1- 29' PROPOSED 6" CONCRETE SLAB FOR DRIVEWAY w X w 0 C) GRADE NOTES FOR ALL FOUNDATION TYPES: 1, THE FOUNDATIONS SHOWN ARE BASED ON A MINIMUM SOIL BEARING PRESSURE OF 1500 PSF. 2. THE SLAB / FOUNDATION MUST BE CLEARED OF ",,--(2)#5 REBAR CONT., ALL DEBRIS, AND COMPACTED PRIOR TO POURING 25" MIN. OVERLAP OF ANY CONCRETE. L 12-ALL JOINTS, ON 3. CONCRETE SHALL MEET THE SPECIFICATIONS 3" HIGH CHAIRS IN THE S-1 GENERAL NOTES PAGE. 12" X 12" LINEAL FOOTER I HEREBY CERTIFY THAT I HAVE REVIEWED THIS PLAN ANMyftaTTO BE IN Cd COMPLI��110IND FBC 7TH EDITr I. AN 5Y)N G 'N6 anti....... 6 Ef �?OFESS�it,t�,A PROFESSIONAL ENGINEER SEAL ENGINEER OF RECORD David W. Smith P.E. FLORIDA LICENSE NUMBER: 53608 Thomas L. Hanson P.E. FLORIDA LICENSE NUMBER: 38654 Ian J. Foster P.E. FLORIDA LICENSE NUMBER: 93654 Joel Falardeau P.E. FLORIDA LICENSE NUMBER: 70667 Erik Stuart P.E. FLORIDA LICENSE NUMBER: 77605 FBC Plans & Engineering Services, Inc. 5344 9th St. Zephyrhills, FL 33542 Phone: (813)838-0735 Email: erb@fbcplans,com Website: www.fbcplans.com CID,& - #29054 DATE: 12/01/2022 DRAWN BY: DENNIS W. DUNN REVISION: DATE: RO 1 22 1215 228 R02 RO 3 R04 JOB # 22 1118 346 TOB NAME & ADDRESS: COLON GRAND HORIZON: LOT 95 37624 LANDIS AVE. ZEPHYRHILLS, FL. 33541 CONTRACTOR: B & H CONSTRUCTION PLANS AND ELEVATIONS S-2 w I HEREBY CERTIFY THAT I HAVE REVIEWED THIS PLAN AND FOUND IT TO BE 1N COMPLIANCE£ WiTYA90F177J(5 AND FBC 7TH EDITiOt ?AND L)(*TTING t' Lj ,. e= r7fJtitt2}titStlii§�� PROFESSIONAL ENGINEER SEAL ENGINEER OF RECORD David W. Smith P.E. FLORIDA LICENSE NUMBER: 53608 Thomas L. Hanson P.E. FLORIDA LICENSE NUMBER: 38654 Ian J. Faster P.E. FLORIDA LICENSE NUMBER: 93654 Joel Falardeau P.E. FLORIDA LICENSE NUMBER: 70667 Erik Stuart P.E. FLORIDA LICENSE NUMBER: 77605 FBC Plans & Engineering Services, Inc. 5344 9th St. Zephyrhills, Fl. 33542 Phone: (813)838-0735 Email; erb@)fbcpians.com Website: vw.fbcpians.com C.0,A. - #29054 DATE: 12/01 /2022 DRAWN BY: DENNIS W. DUNN REVISION: DATE; RO 1 22 1215 228 RO 2 RO 3 RO 4 JOB # 22 1118 346 JOB NAME & ADDRESS: COLON GRAND HORIZON: LOT 95 37624 LANDIS AVE. ZEPHYRHILLS, FL. 33541 CONTRACTOR: B & H CONSTRUCTION PLANS AND ELEVATIONS I I I MFD. HOME CJ 2X6 SMB r_ 2X6 SMB RMM ------------- 4" CONCRETE SLAB W/ 12" X 12" FOOTER 12' REAR ELEVATION LEFT SIDE ELEVATION 2X6 SMB 2X6 SMB I MFD. ----------------------- HOME FACTORY .... PORCH >< PAVERS " 12" X 12" 12' —6X6" LINEAL FOOTER LINEAL FOOTER PROPOSED CARPORT W1 SHED AND STEPS BEYOND FRONT ELEVATION I HEREBY CERTIFY THAT I HAVE REVIEWED THIS PLAN AND FOUND IT TO BE IN COMPLIANCE W��AASCE 7-16 MJEXANDTING FBC 7TH " STRING ED Q- jj <3 �`ESS\C�\' PROFESSIONAL ENGINEER SEAL ENGINEER OF RECORD David W. Smith P.E. FLORIDA LICENSE NUMBER: 53608 Thomas L. Hanson P.E. FLORIDA LICENSE NUMBER: 38654 Ian J. Foster P.E. FLORIDA LICENSE NUMBER: 93654 Joel Falardeau P.E. FLORIDA LICENSE NUMBER: 70667 Erik Stuart P.E. FLORIDA LICENSE NUMBER: 77605 FBC Plans & Engineering Services, Inc. 5344 9th St Zephyrhills, Fl. 33542 Phone: (813)838-0735 Email: erb@fbcpians.com Website: www.fbcplans.com C.O.A. - #29054 DATE: 12101/2022 DRAWN BY: DENNIS W. DUNN REVISION: DATE: RO 1 22 1215 228 RO 2 RO 3 RO 4 JOB # 22 1118 346 JOB NAME & ADDRESS: COLON GRAND HORIZON: LOT 95 37624 LANDIS AVE. ZEPHYRHILLS, FL. 33541 CONTRACTOR: B & H CONSTRUCTION PLANS AND ELEVATIONS S-4 S.M.B. DEPTH S.M.B.WEB _T�CORROSION N RESISTANT UPLIFT I HEREBY CERTIFY THAT I HAVE REVIEWED 6" MIN, "H" WALL "TT SIZE CAPACITY THIS PLAN AND FOUND IT TO BE IN RECOMMEND ALUMINUM FLASHING INSTALLED BELOW DRIP EDGE TO 4" �04F �0611 (2) 3/8" BOLTS, NUTS, WASHERS 1,720 LBS COMPLIANCE W,} if_KF4T7 ANDFBC7TH EDITION R tl�VYPT�NG IS FASCIA. CAULK ALL SEAMS, (2) 318' BOLTS, NUTS, WASHERS 2,550 LBS BUILD1,NI§' rTING� ROOI, '0501, .0611 (3) 3/8" BOLTS, NUTS, WASHERS 2,550 LBS \j — — — — — — — — — — — ALUMINUM FLASHING ATTACHED 7" �055" . .061, (3)3/8 BOLTS, NUTS, WASHERS 3,500 LBS I x W1 #8 X 3/4" TEK SCREW AND 1 "0 7" 055" 0911 (3) 318" BOLTS, NUTS, WASHERS 3,600 LBS �� _v 1/% NEOPRENE WASHER AT EACH RIB 7" .0551, .12F (3) 3/8" BOLTS, NUTS, WASHERS 8" .072" .06" (4} 3/8" BOLTS, NUTS, WASHERS 4,500 LBS 5,500 LBS 8" 072" A911 (4) 3/8" BOLTS, NUTS, WASHERS 7,000 LBS aLO ALUMINUM RISER 8"'072" (4) 318' BOLTS, NUTS, WASHERS 7,000 LBSLJ f PAN Roo .125" 072" Q, 9. 06" (4) 318" BOLTS, NUTS, WASHERS 7,000 LES 0 .09, (4) 3/8" BOLTS, NUTS, WASHERS 9. 7 IRS WASHERS 125" (4) 3/8" BOLTS, NUT A , 8,900 LBS I 9,500 LBS 2X .08 7?" 92 3/8" BOLTS, NUTS: < HOST BEAM SMB PER PLAN 10, .125" (4) 1 11 ,000LBS F 0 NOTE: OTHER BOLT SIZES AND QUANTITIES MAY BE USED PER SITE SPECIFIC PLANS AND CALCULATED UPLIFT CAPACITY REQUIRED 0 Lij 2 0 ATTACH PANS TO 0.060" MIN. HEADER PROFESSIONAL ENGINEER SEAL CHANNEL W1 (4) # 10 X 3/4" TEK SCREW PER PAN AT BACK OF PAN ENGINEER OF RECORD FASTEN 0.060' MIN. HEADER CHANNEL TO HOST # 10 X 3/4" TEK SCREW AND ALUMINUM E David W. Smith P.E. BEAM WITH 114"0 X 2-1/2" LAG SCREW AT 24" D.C., 3/4"0 NEOPRENE WASHER PAN ROOF 2 ROWS STAGGERED. STRIP SEALANT [RISER 4 PER PAN AT ALL BEAMS FLORIDA LICENSE NUMBER: 53608 BETWEEN FASCIA AND HEADER CHANNEL AND 8" D.C. AT RAKE Thomas L. Hanson P.E. FASTEN RECEIVING CHANNEL TO HOST BEAM WITH 1/4'0 X 2" LAG SCREW, 1 SCREW PER 2 INCHES OF FLORIDA LICENSE NUMBER: 38654 BEAM HEIGHT. FASTEN BEAM TO RECEIVING CHANNEL W/ #10 X 3/4" TEK SCREW, 1 SCREW PER 2X SMB PER PLAN Ian J. Foster P.E. INCH OF BEAM HEIGHT STAGGERED, BOTH SIDES FLORIDA LICENSE NUMBER: 93654 RISER PAN ROOF AND BEAM CONNECTION TO MFG HOST BEAM (N) 3/8" THRU BOLTS, WASHERS, AND NUTS, CORROSION RESISTANT, Joel Falardeau P.E. TYPICAL (SEE CHART) FLORIDA LICENSE NUMBER: 70667 ALUMINUM POST COLUMN PER PLAN FASTEN RECEIVING CHANNEL Erik Stuart P.E. TO SMB W/ #10 X 3/4" TEK SCREW ALUMINUM PAN ROOF, POST AND BEAM CONNECTION FLORIDA LICENSE NUMBER: 77605 FASTEN SMB TO RECEIVING (1 SCREW PER INCH OF BEAM HEIGHT) CHANNEL W/ #10 X 3/4" TEK SCREW STAGGERED, BOTH SIDES FBC Plans & Engineering (I PER INCH OF BEAM HEIGHT) Ao 1-1/2" X 2-1/8"X 1-1/2'X 0.062" Services, Inc. STAGGERED, BOTH SIDES INTERNAL OR EXTERNAL RECEIVING CHANNEL 5344 9th St. -7. Zephyrhills, Fl. 33542 o Phone: (813)838-0735 '� _V) F2X Email: erb9fbcpIans,cmn SMB PER PLAN . T t Website: www.fbcplans.com - 2 -D 2X SMB PER PLAN 2� COA. - #29054 OE —Z) 0 0 DATE: 12/01/2022 .062 MIN, RECEIVING CHANNEL 0 0 F- (2) 3/8"0 MACHINE BOLTS, FASTENED TO POST W/ #10 X 3/4" TEK SCREW PER INCH OF BEAM FASTEN RECEIVING CHANNEL 0 < NUTS AND WASHERS ALUMINUM 3X3 POST DRAWN BY: DENNIS W. DUNN (1 TO STRUCTURAL WALL MEMBER 3:3: HEIGHT) STAGGERED WITH 1/4"0 X 2" LAG SCREW U_ EXTERNAL BASE INTERNAL BASE REVISION: DATE: BEAM TO POST CONNECTION (1 SCREW PER 2 INCHES OF J---JV—L OPTION 2 OPTION I BEAM HEIGHT) 11 GA. EXTERNAL ALUMINUM BASE 11 GA, INTERNAL ALUMINUM BASE RO 1 22 1215 228 BEAM TO WOOD WALL CONNECTION PREDRILL VERTICAL FLANGES PREDRILL VERTICAL FLANGES RO 2 (2) 3/8"0 CONCRETE ANCHORS PER (4) 1/4"0 CONCRETE ANCHORS RO 3 EXTERNAL FLANGE WITH 2'O,C. SPACING, W1 3' EMBEDMENT, 3" MIN, EDGE 2-3/4" MIN. EMBEDMENT AND 3" MIN. DISTANCE AND 2' MIN. SPACING RO 4 FASTEN RECEIVING CHANNEL CONCRETE EDGE DISTANCE TO CARRIER BEAM W/ #10 X 3/4" JOB# 22 1118 346 TEK SCREW (I SCREW / INCH CONCRETE JOB NAME &ADDRESS: OF BEAM HEIGHT) STAGGERED COLON 1-1/2" X 2-1/8" X 1-1/2" X 0,062" GRAND HORIZON: LOT 95 RECEIVING CHANNEL 3X3 ALUMINUM POST CONNECTION 37624 LANDIS AVE. CARR R P�Afv TO CONCRETE SASE ZEPHYRHILLS, FL. 33541 CONTRACTOR: NOTE: B & H CONSTRUCTION FASTEN RECEIVING CHANNEL TO CONNECTIONS SHALL BE OF SUFFICIENT MID -SPAN BEAM W1 #10 X 3/4" TEK SCREW LENGTH FOR REQUIRED EMBEDMENT INTO (1 SCREW / INCH OF BEAM HEIGHT) CONCRETE WHEN A PAVER DECK IS PRESENT ALUMINUM CARPORT STAGGERED BOTH SIDES DETAILS BEAM TO BEAM CONNECTION S-5 PRODUCTAPPROVALCODE CHART STRUCTURAL COMPONENTS SIMPSON SP1/SP2 FL10456 SIMPSON H3 FL10456 SIMPSON H2.5T FL10446 SIMPSON HTT4/HTT5 FL1 1496 SIMPSON SSP/DSP/SPH FL10456 SIMPSON ALL CONNECTORS AND FASTENERS IN CONTACT WITH TREATED WOOD SHALL BE ZINC COATED GALVANIZED STEEL OR SIMPSON'ZMAX' FASTEN RECEIVING CHANNEL TO SMB W1 #10 X 3/4" TEK SCREW (1 SCREW PER INCH OF BEAM HEIGHT) STAGGERED, BOTH SIDES FASTEN RECEIVING CHANNELTO STRUCTURAL WALL MEMBER WITH 1/4"0 X 211 LAG SCREW (1 SCREW PER 2 INCHES OF BEAM HEIGHT) HEADERS AT SIZE SPAN JACK ALL WOOD STUDS LOAD BEARING WALL STUDS (2) 2"x4" 4'4" 1 AND BLOCKING FOR SUPPORTING (2) 2"x6" 6'4' 1 ALUMINUM RISER (2) 2"x8" 8'-0" 2 WALLS SHALL BE 2X4 PAN ROOF (2) 2"x10" 9'-6" 2 1(2) 2"x12" 111'-6" 2 HEADERS WITH 1/2" PLYWOOD SPACER, GLUED AND NAILED W/ 16d NAILS AT 24" O.C. (2 ROWS STAGGERED). FOR HEADERS OF DOORS OR WINDOWS DIRECTLY UNDER GABLE SEE PLANS SIMPSON H2.5T OR EQUIV. FASTENED PER MFGR'S SPECS. SIMPSON (2) H2.5T OR EQUIV. _\ FASTENED PER MFGR'S SPECS. 2X CRIPPLE STUD A 16" O.C. (N) 2X JACK STUD PER TABLE SIMPSON LSTA OR MSTA STRAP OR EQUIV. FASTENED APPROX. 4" ABOVE AND BELOW HEADER PER MFGR'S SPECIFICATIONS 2X SILL PLATE ATTACH JACK STUD TO KING STUD W/ 16d NAILS AT 24" O.C. 2X CRIPPLE STUD A 16" O.C. (N) 2X HEADER WITH 1/2" PLYWOOD SPACER PER TABLE 0 2XSMB PER PLAN _j z <_j C9 Z FOR MID -SPAN BEAM 0 0 U_ CO IF REQUIRED s R 1-1/2" X 2-1/8" X 1-1/2" X 0.062" INTERNAL OR EXTERNAL RECEIVING CHANNEL # 10 X 3/4" TEK SCREW W/ 3/4"0 NEOPRENE WASHER, 4 PER PAN :0 1 2X SMB PER PLAN 0 ummitur-a 11 mmww.. e, rawalawmaRt� �07 , �11 - , cI SIMPSON H2.5T, H3 OR EQUIV. FASTENED PER MFGR'S SPECS. DBIL 2X (N) 2X HEADER WITH SIMPSON SP2 OR H2.5T TOP PLATE 1/2" PLYWOOD SPACER OR EQUIV. FASTENED A I I PER TABLE [PER MFGR'S SPECS. HOST BEAM 6" MIN' RECOMMEND ALUMINUM FLASHING INSTALLED BELOW DRIP EDGE TO ROOHOST BEAM, CAULK ALL SEAMS. F - - — — — — — — — — ALUMINUM FLASHING ATTACHED I x W1 #8 X 3/4" TEK SCREW AND 1 "0 I NEOPRENE WASHER AT EACH RIB Z ALUMINUM RISER PAN ROOF FASTEN ALUMINUM RISER PAN ROOF TO TOP PLATE WITH #12 TEK SCREW WITH 3/4"0 NEOPRENE WASHER, 4 PER PAN AT ENDS AND 8" O.C. AT RAKE WITH 1-1/2" EMBEDMENT MIN. DBL 2X TOP PLATE (ONLY NON -TREATED WOOD IN CONTACT W/ ALUMINUM ROOF OR PROVIDE IMPERVIOUS MOISTURE BARRIER) (N) 2X HEADER WITH 1/2' PLYWOOD SPACER OVER WINDOWS AND DOORS. SEE HEADER TABLE INSTALL WINDOWS PER MFGR'S INSTALLATION INSTRUCTIONS 1/2" P.T. PLYWOOD, MIN. 2' HIGH (NON-P.T. OR OSB ALLOWED ABOVE 2') SHEATHING SHALL OVERLAP BOTTOM AND TOP PLATES VINYL SIDING OF CHOICE APPLIED PER MFGR'S SPECIFICATIONS 2X P.T. WOOD STUDS AT 16" O.C. 2X P.T. BASE PLATE 1/2"0 WEDGE ANCHOR WITH STANDARD WASHER, 12" FROM CORNERS, 6' FROM OPENINGS AND 24" O.C. WITH 4" MIN. EMBEDMENT AND 1-3/4" MIN. EDGE DISTANCE TYPICAL ATTACH PANS TO 0,060" MIN. HEADER 2 CHANNEL W/ (4) # 10 X 3/4" TEK SCREW LL 0 PER PAN AT BACK OF PAN FASTEN 0.060" MIN. HEADER CHANNEL TO HOST BEAM WITH 1/4"0 X 2-1/2" LAG SCREW AT 24" O.C., 2 ROWS STAGGERED. STRIP SEALANT BETWEEN FASCIA AND HEADER CHANNEL ALUMINUM RISER PAN ROOF CONNECTION TO MFG. HOST BEAM NOTE: VINYL SIDING MUST BE INSTALLED OVER A MINMUM 7/16" WOOD STRUCTURAL PANEL SHEATHING (PLYWOOD OR OSB) 2X BLOCKING FOR PANEL SPLICE WHERE WALL HEIGHT EXCEEDS PANEL LENGTH WALL PANELS (PLYWOOD) NAILING NOTE: NAIL 8d NAILS 6" O.C. AT EDGES AND 12" O.C. IN FIELD. ROWS OF NAILS SHALL BE 1/2" MIN. FROM PANEL EDGES, PLYWOOD SHEATHING SHALL OVERLAP BOTH TOP AND BOTTOM PLATES. ALL FASTENERS NAILED PER MANUFACTURERS SPECIFICATIONS. WHEN SHEATHING PANELS ARE CONTINUOUS FROM TOP TO BOTTOM PLATE (8'OR LESS) SIMPSON STUD PLATE TIES ARE REQUIRED ONILT AT THE CORNERS AND EACH SIDE OF OPENINGS AND SHEATHING IS NAILED PER PANEL NAILING NOTE. WHEN SHEATHING PANELS ARE NOT CONTINUOUS, SIMPSON STUD PLATE TIES ARE REQUIRED AT ALL STUDS. SP1, H2.5T OR H3 2X WALL STUD-' 6"X6" #10 WWM (OR FIBERMESH) 4" 2500 PSI CONCRETE SLAB WITH AT 16" O.C. PER R318.7 GRADE f OVER 6 MIL. POLY VAPOR BARRIER CONCRETE BELOW W/ EDGES LAPPED 6" AND SEAMS TAPED, OVER CLEAN, COMPACTED, GRADE PER R403.1 ------- 44 TERMITE TREATED SOIL. Oy P.T, MACC: INSTALL WINDOWS AND DOORS IN OPENINGS PER MANUFACTURERS INSTALLATION INSTRUCTIONS 12" FROM CORNERS, 6" FROM OPENINGS OR EQUIV. FASTENED NO 24" O.C. WITH 4" MIN. EMBEDMENT PER MFGR'S SPECS, AND 1-3/4" MIN. EDGE DISTANCE TYPICAL FRAMING FOR OPENINGS WITH HEADERS ADQOM IZD1 H2.5T, W3 OR EQUIV, FASTENED (2)#5REBARCONTINUOUS, _/ PER MFGR'S SPECS. 25" MIN. OVERLAP ALL JOINTS, ON 3" HIGH CHAIRS FOOTING WIDTH AND DEPTH SIZE AS PER R403.1 AND B1809.4 I HEREBY CERTIFY THAT I HAVE REVIEWED THIS PLAN AND FOUND IT TO BE IN COMPLIANCE WITH ASCE 7-16 AND FBC 7TH EDITION RESIQFNJIqEND EXISTING BUILDINqNkX" I// LA. C:; p. ........ PROFES INEER SEAL ENGINEER OF RECORD David W. Smith P.E. Thomas L. Hanson P.E. Ian J. Foster P.E. Joel Falardeau P.E. FLORIDA LICENSE NUMBER: 70667 Erik Stuart P.E. FLORIDA LICENSE NUMBER: 77605 FBC Plans & Engineering Services, Inc. 5344 9tb St. Zephyrhills, Fl. 33542 Phone: (613)838-0735 Email: erb@fbcplans.com Website: www.fbcplans.com C.O.A. - #29054 DATE: 12/01/2022 DRAWN BY: DENNIS W. DUNN REVISION: DATE: RO 1 22 1215 228 RO 2 RO 3 R04 JOB # 221118346 68114&1a 61,}� COLON GRAND HORIZON: LOT 95 37624 LANDIS AVE. ZEPHYRHILLS, FL. 33541 CONTRACTOR: wo TABLE SPANS ARE FOR #2 SYP (SOUTHERN YELLOW PINE] 16 O.C. GIRDER SPAN LENGTHS DECK JOIST SPANS DECK JOIST SPAN < OR = TO (FEET) JOIST SPAN GIRDER SIZE 61 8' 10, 12' PT 2X6 9' MAX DBL PT 2X6 61-11, 5'-11" 5'-4" 4'-10" PT 2X8 12' MAX _._,_....... _ _..._., DBL PT 2X8 8 9" T-7" 6-9" 6'-2" PT 2X10 14' MAX BL PT 2X10 10`-4"9'-0"8'-0"7'-4" PT 2X12 16'-6" MAX [DBL PT 2X12 12'-2° 10'-7" 9'-5" SPANS PER FBC 7TH EDITION R507.5 AND R507.6 PRODUCT APPROVAL CODE CHART STRUCTURAL COMPONENTS ALL STRUCTURAL HARDWARE COMPONENTS FASTENED PER SIMPSON A35 FL10446 MANUFACTURER'S SPECIFICATIONS. SIMPSON ABU44 FL10860 SIMPSON AC4R FL10860 NOTE: SIMPSON H3 FL10456 ALL CONNECTORS AND FASTENERS IN CONTACT W/ TREATED WOOD SIMPSON ML26 FL10446 SHALL BE ZINC COATED GALVANIZED SIMPSON LUS26 FL10531 STEEL OR SIMPSON 'ZMAX'. SIMPSON SUR/SUL FL10531 SIMPSON AC4R POST CAP EACH SIDE OF POST I UNLESS OTHERWISE NOTED I II € I I € DBL PERIMETER JOIST I OR DBL. FLUSH GIRDER 4X4 POST I I IjI € DBLPERIMETER JOIST OR € LBC--�USH GIRDER TO 4X4 POST_ P.T. 4X4 POST FASTEN DBL. ANGLED PERIMETER JOIST TO INSIDE OF 4X4 POST W/ (1) SIMPSON AC4R POST CAP OR EQUIV. NOTE: TYPICAL AT 4 POSTS P.T. 2X6 (FLAT) (OPTION A AND B) 5y2" 2' ARE ONLY REQUIRED WHERE A HANDRAIL POST IS BEING ATTACHED FASTEN DBL, PERIMETER JOIST TO DBL. PERIMETER JOIST W/ SIMPSON SUR/SUL SKEWED HANGER, OR A35 ADJUSTABLE ANGLE, OR EQUIV. (OPTION A) P.T. 2X6 (FLAT) TYPICAL EACH CORNER IF REQUIRED, ATTACHED TO JOISTS WITH 3" DECK SCREWS AS SHOWN FASTEN COMPOSITE DECKING---_— — W/ #10 X 2" SCREWS, 2 PER BOARD AT EVERY JOIST (OPTION B) — P.T. 2X6 (FLAT) TYPICAL EACH SIDE IF REQUIRED, ATTACHED TO JOISTS WITH 3" DECK SCREWS AS SHOWN P.T. 2X4 COMBINATION POST—/ 4'-5," (3) 2X4 P.T. NAILED TOGETHER W/ 8d GALV. NAILS APPROX. 4" O.C. AND 6 PER 2X6 JOISTS TYPICAL 4 PLACES DBL. P.T. 2X6 FLUSH GIRDER/JOIST FASTEN W/ SIMPSON L50 ANGLE OR EQUIV, ON EACH SIDE, AT EACH END —17 4X4 POST — e SIMPSON ABU44 OR EQU€V. I W/ 1/2" WEDGE ANCHOR € € 3" IMBEDMENT (2000# UPLIFT) I I PER MFGR'S. SPECS. I € 4X4 POST CONNECTION I TO CONCRETE_ _ P.T. 2 X 4 COMBINATION POST FASTEN TRPL. 2X4 POST I 1 I TO SLAB WITH 2" X 2" X 1/8" I i PERIMETER I I ANGLE W/ (2) 1/4" TAPCONS, I 2" EMBEDMENT. FASTEN ANGLE SIMPSON TP37 TIE PLATE TO POST W/ (2) #10 X 2" LAG SCREWS. AT OUTSIDE CORNERS 2XgOIST AND SIMPSON ML26 ANGLE COMBINATION I I CONCRETE I I AT INSIDE CORNERS POST I i I 2X4 COMBINATION POST 2X4 COMBINATION POST _ — TO PERIMETER JOIST ^ ! _ _ TO CONCRETE DBL. P.T, 2X6 PERIMETER JOIST TYPICAL 2' 5Y2„ is FASTEN FLOOR JOIST TO ANGLED PERIMETER JOIST W1 SIMPSON SUR/SUL SKEWED HANGER, OR A35 ADJUSTABLE ANGLE, OR EQUIV. AT EACH END P.T. 2X6 FLOOR JOIST AT 16" O.C. MAX. FASTEN W/ SIMPSON LUS26 JOIST HANGER OR EQUIV. AT EACH END TYPICAL P.T. 2X6 PERIMETER JOIST TYPICAL 4'-5Y2 8'-11" FASTEN 2X4 COMBINATION POST TO PERIMETER JOIST W/ SIMPSON TP37 TIE PLATE TYPICAL AT OUTSIDE CORNERS AND P.T. 4X4 POST SIMPSON ML26 ANGLE AT INSIDE CORNERS FASTENED TO DBL GIRDER/JOIST W/ (2) SIMPSON AC4R POST CAP OR EQUIV. TYPICAL AT 2 POSTS WOOD LANDING FLOOR JOIST GIRDER LAYOUT [ s — — I€ II IIII *--L510—A—NG­LE SO SIMPSON SURISUL SKEWED HANGER OR ADJUSTABLE ANGLE SGL. / DBL ANGLED PERIMETER JOIST DBL PERIMETER JOIST DBL. FLUSH GIRDER FLOOR JOIST ANGLE SHOWN} #IItItj I FLOOR JOIST DBL. GIRDER TO JOIST TO ANGLED DBL. PERIMETER JOIST SI'v" SUR/SUL SKEWED HANGER OR SIMPSON LUS26 A35 ADJUSTABLE ANGLE JOIST HANGER 7 I I € I I DBL. € I DBL FLUSH GIRDER I I d PERIMETER JOIST OR l SGL. PERIMETER JOIST 1) I DBL. (A35 ANGLE SHOWN) FLOOR JOIST i I PERIMETER JOIST € € FLOOR JOIST i DBL. PERIMETER JOIST TO DBL. GIRDER/PERIMETER JOIST TO DBL. PERIMETER JOIST I HERESY CERTIFY THAT I HAVE REVIEWED THIS PLAN AND FOUND IT TO BE IN COMPLIANCE WIT 7-16 AND FBC 7TH EDITION RESJUN j � VW1 '111G BUILDIM\11 , /f� PROFESSIONAL ENGINEER SEAL ENGINEER OF RECORD David W. Smith P.E. FLORIDA LICENSE NUMBER: 53608 Thomas L. Hanson P.E. FLORIDA LICENSE NUMBER: 38654 Ian J. Foster I.E. FLORIDA LICENSE NUMBER: 93654 Joel Falardeau P.E. FLORIDA LICENSE NUMBER: 70667 Erik Stuart P.E. FLORIDA LICENSE NUMBER: 77605 FBC Plans & Engineering Services, Inc. 5344 9th St. Zephyrhills, FI.33542 Phone:(813)838-0735 Email: erb@fbcplans.com Website: www.fbcplans.com C.O.A. - #29054 I DATE: 12/01/2022 1 I DRAWN BY: DENNIS W. DUNN I REVISION: DATE: RO 2 RO 2 RO 3 RO 4 JOB # 22_1118_346 IOB NAME & ADDRESS: COLON GRAND HORIZON: LOT 95 37624 LANDIS AVE. ZEPHYRHILLS, FL. 33541 CONTRACTOR: B & H CONSTRUCTION WOOD LANDING DETAILS M NEWEL POST FASTEN TO CONCRETE SEE'POST BASE CONNECTION DETAIL' —HANDRAIL ATTACHED AT EACH PICKET W1(2) #10 X 3/4° CORROSION RESISTANT SCREWS PICKET SIZE AND SPACING SHALL NOT ALLOW PASSAGE OF A SPHERE 4" IN DIAMETER PER FBC R312 6' O.C. MAX TYPICAL TOP AND BOTTOM RAIL ATTACHED TO NEWEL POSTS OR STRUCTURAL POST PER PLAN W/ 1-1/2" X 1-1/2" X 3/16" ANGLE W/ (2) #10 X 3/4" TEK EACH FLANGE. ATTACHMENT TO BE AT UNDERSIDE OF RAILING TRIANGULAR OPENING SUCH THAT A 6" DIA. SPHERE WILL NOT PASS PER FBC R312 EXCEPTION NEWEL POST TYPICAL EACH PICKET ATTACHED TO BOTTOM RAIL W/ (2) #10 X 3/4" CORROSION RESISTANT SCREWS EACH PICKET ATTACHED TO TOP AND PICKET SIZE AND SPACING SHALL NOT BOTTOM RAIL W/ (2) #10X3/4" CORROSION RESISTANT SCREW ALLOW PASSAGE OF A SPHERE 4" 1N 6' O.C. DIAMETER PER FBC R312 NEWEL POST OR MAX. STRUCTURAL POST TYPICAL ituffiflusaws °— TOP AND BOTTOM RAIL ATTACHED NEWEL POST TO NEWEL POST OR STRUCTURAL FASTEN TO DECK POST PER PLAN WITH 1-1/2" X 1-1/2" X 3/16" SEE "POST BASE TO ANGLE W/(2) #10X3/4" TEK SCREW EACH FLANGE. WOOD DECK" DETAIL ATTACHMENT TO BE MADE AT UNDERSIDE OF RAILING RAILING ON WOOD DECK 4"X4"X16"P SPLIT BRICKS, MC NOTE: ALL BRICK DIMENSIONS ARE NOMINAL. MAXIMUM RISER HEIGHT: 7-3/4" TREAD DEPTH: 10" MIN. RISER HEIGHT = 7-3/4" MAX. HEIGHT DIFFERENCE BETWEEN RISERS SHALL NOT EXCEED 3/8". TREAD DEPTH = 10" MIN. (NOT INCLUDING NOSING) A NOSING NOT LESS THAN 3/4" AND NOT MORE THAN 1-1/4" SHALL BE PROVIDED ON STAIRWAYS WITH SOLID RISERS, NOSING NOT REQUIRED WHERE TREAD DEPTH IS A MIN. OF 11 INCHES. 2-1/4" X 48" X 48" PRE -CAST LANDING W/ REBAR 2-1/4" PRE -CAST TREADS W/REBAR TYPICAL STEPS WITH PRECAST TREADS ARID LANDING NOTE: ALUMINUM STRUCTURAL RAILINGS OR OTHER COMMERCIAL MANUFACTURED RAILING THAT MEET FLORIDA BUILDING CODE REQUIREMENTS AND HAVE FLORIDA PRODUCT APPROVAL NUMBER MAY BE SUBSTITUTED IN LIEU OF TYPICAL CONTRUCTION SHOWN. STAIRS AND RAILINGS SHALL BE CONSTRUCTED IN COMPLIANCE WITH FBC 7TH EDITION SECTIONS R311 AND R312. TYPE 1 STANDARD ALUMINUM MAXI -RAIL DESIGNED TO WITHSTAND 200LBS OF LATERAL LOAD 2 X 2 ATTACH WITH (4) 3/16"0 ALUMINUM NEWEL POST MASONRY SCREW NEWEL POST SECURED ANCHOR WITH 2" MIN. TO BASE BY CONTINUOUS EMBEDMENT AND 1-1/2" 3/32 MIS WELD AT BOTTOM MIN. EDGE DISTANCE POST BASE TO CONCRETE :ONCRETE SLAB ATTACH TO WOOD PLANKING W/ (4) 3/8'"0 X 2-1/2" LAG SCREWS AND 2" X 2" ATTACH TO COMPOSITE PLANKING ALUMINUM NEWEL POST W( (4} #10 X 2-1/2" SCREWS INTO NEWEL POST SECURED JOIST OR BLOCKING TO BASE BY CONTINUOUS DECK PLANKING 3/32 MIS WELD AT BOTTOM WOOD OR COMPOSITE POST BASE TO WOOD DECK I HEREBY CERTIFY THAT I HAVE REVIEWED THIS PLAN AND FOUND IT TO BE IN COMPLIANCE WITH ASCE 7-16 AND FBC 7TH EDITION fkI{ iiLW[WYAnp7XISTiNG BuiI.n R �F, F F Oa f a L,_j = E. �11til##F331F11t1` PROFESSIONAL ENGINEER SEAL ENGINEER OF RECORD David W. Smith P.E. FLORIDA LICENSE NUMBER: 53608 Thomas L. Hanson P.E. FLORIDA LICENSE NUMBER: 38654 Ian J. Foster P.E. FLORIDA LICENSE NUMBER: 93654 Joel Falardeau P.E. FLORIDA LICENSE NUMBER: 70667 Erik Stuart P.E. FLORIDA LICENSE NUMBER: 77605 FBC Plans & Engineering Services, Inc. 5344 9th St. Zephyrhills, FI. 33542 Phone:(813)838-0735 Email: erb@fbcplans.com Website: www.fbcplans.com C,O.A. - #29054 I DATE: 12/01/2022 1 R REVISION: DATE: RO 1 RO 2 RO 3 RO 4 JOB # 22_1118_346 JOB NAME & ADDRESS: COLON GRAND HORIZON: LOT 95 37624 LANDIS AVE. ZEPHYRHILLS, FL. 33541 CONTRACTOR: ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE AC ALTERNATING CURRENT BLDG 1, THIS SYSTEM IS GRID—INTERTIED VIA A UL—LISTED BUILDING CONC CONCRETE DC DIRECT CURRENT POWER —CONDITIONING INVERTER, _.. EGC EQUIPMENT GROUNDING CONDUCTOR (E) 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. EXISTING EMT ELECTRICAL METALLIC TUBING FSB 3. A NATIONALLY —RECOGNIZED TESTING LABORATORY FIRE SET —BACK GALV GALVANIZED GEC GROUNDING SHALL LIST ALL EQUIPMENT IN COMPLIANCE WITH ELECTRODE CONDUCTOR GND GROUND HDG HOT ART, 110,3. DIPPED GALVANIZED I CURRENT Imp CURRENT AT 4, WHERE ALL TERMINALS OF THE DISCONNECTING MAX POWER Isc SHORT CIRCUIT CURRENT kVA MEANS MAY BE ENERGIZED IN THE OPEN POSITION, KILOVOLT AMPERE kW KILOWATT LBW LOAD A SIGN WILL BE PROVIDED WARNING OF THE BEARING WALL MIN MINIMUM (N) NEW NEUT HAZARDS PER ART. 690.17. NEUTRAL NTS NOT TO SCALE OC ON CENTER PL 5. EACH UNGROUNDED CONDUCTOR OF THE PROPERTY LINE POI POINT OF INTERCONNECTION MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY PV PHOTOVOLTAIC SCH SCHEDULE S STAINLESS PHASE AND SYSTEM PER ART. 210.5. STEEL STC STANDARD TESTING CONDITIONS TYP 6. CIRCUITS OVER 250V TO GROUND SHALL COMPLY TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V WITH ART. 250.97, 250.92(B). VOLT Vp VOLTAGE AT MAX POWER Voc VOLTAGE 7. DC CONDUCTORS EITHER DO NOT ENTER BUILDING AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT OR ARE RUN IN METALLIC RACEWAYS OR ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER ART. 690.31(E). 8, ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY UL LISTING, 9. MODULE FRAMES SHALL BE GROUNDED AT THE UL—LISTED LOCATION PROVIDED BY THE MANUFACTURER USING UL LISTED GROUNDING HARDWARE. 10, MODULE FRAMES, RAIL, AND POSTS SHALL BE BONDED WITH EQUIPMENT GROUND CONDUCTORS. VICINITY MAP INDEX Sheet 1 COVER SHEET Sheet 2 SITE PLAN Sheet 3 STRUCTURAL VIEWS Sheet 4 UPLIFT CALCULATIONS LICENSE GENERAL NOTES Sheet 5 THREE LINE DIAGRAM v- Cutsheets Attached 1. ALL WORK SHALL COMPLY WITH THE 2020 3 f FLORIDA BUILDING CODE (7TH EDITION), FLORIDA FIRE PREVENTION CODE (7TH EDITION). 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2017 NATIONAL ELECTRIC CODE. y MODULE GROUNDING METHOD: ZEP SOLAR ZePhyrhills City , REV BY GATE COMMENTS E y REV A I CAL 12/13/22 BOS RELOCATED UTILITY: Duke Energy (FL) j L?— 3 3 51 6 9 0 00 J tXISTO�iEft: CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: DESCRIPTION: DESIGN: l CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: LIkh1t Jain 11,6 KW PV ARRAY Carlos Ang Lora MEW SHALL IT BE DISCLOSED IN MOLE OR IN ZS Comp V4 w Flashing —Insert 7847 Sail Clever Ln 7.6 K (AC NAMEPLATE) PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES: Z e P � rh I I S FL 40 ORGANIZATION, EXCEPT IN CONNECTION NTH THE SALE AND USE OF THE RESPECTIVE (29) TeSlo # T400H , TESLA EQUIPMENT, WTHOUT THE #BITTEN INVERTER:a /� � PERMISSION OF TESLA INC. 18482340078 7.6 kW Tesla Inc 1538000—QO—F 240V PAGE NAME: OVER SHEET SHEET; DATE: 1 A 12 13 2022 % i m — — —D — , l ` iIfIv co 0 ---- - 0 o ! 3' CO (E) DRIVEWAY - - IL S �mpi \ \ — — — — — — — -- m CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: J g_ 3 3 516 9 0 00 CONTAINED SHALL NOT BE USED FOR THE ®®_ BENEFIT OF ANYONE EXCEPT TESTA INC., NOR MOUNTING SYSTEM: MALL IT BE DISCLOSED IN MOLE OR IN ZS Camp V4 w Flashing insert PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WTH THE SALE AND USE OF THE RESPECTIVE MODULES: (29) Tesic # T400H TESTA EQUIPMENT, 'WITHOUT THE WITTEN INVERTER: PERMISSION OF TESTA INC. 7.6 kW Tesla Inc 1538000-00—F (24, Likhit Jain 7847 Sail Clover Ln Zephyrhills, FL 33540 Q) 0 00 r- Front Of House PITCH: 23' (5:12) ARRAY PITCH-231 (5:12 MPl AZIMUTH:180 ARRAY AZIMUTH:180 MATERIAL: Camp Shingle STORY: 2 Stories PITCH: 23' (5:12) ARRAY PITCH:231 (5:12 MP2 AZIMUTH:270 ARRAY AZIMUTH:270 MATERIAL: Comp Shingle STORY: 2 Stories PITCH: 23" (5:12) ARRAY PITCH: 231 (5:12 MP3 AZIMUTH:0 ARRAY AZIMUTH:0 MATERIAL: Comp Shingle STORY: 2 Stories PITCH: 230 (5:12) ARRAY PITCH:231 (5:12 MP4 AZIMUTH: 90 ARRAY AZIMUTH: 90 MATERIAL: Comp Shingle STORY: 2 Stories (E) UTILITY METER & WARNING' LABEL Icy INVERTER W/ INTEGRATED DC DISCO WARNING LA BELS Dc DC DISCONNECT & WARNING LABELS m AC AC DISCONNECT & WARNING LABELS 10 DC JUNCTION/COMBINER BOX & LABELS DISTRIBUTION PANEL & LABELS - LOAD CENTER & WARNING LABELS DEDICATED PV SYSTEM METER RSD RAPID SHUTDOWN 0 STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR — GATE/FENCE HEAT PRODUCING VENTS ARE RED it INTERIOR EQUIPMENT IS DASHED L=J SITE PLANN TOTAL ARRAY AREA (SF): 629 scale: lJ8" = 1' TOTAL ROOF AREA (SF):1917 w E TOTAL ARRAY AREA IS �8 32.8 0 1' 8' 16` 1 + PERCENT OF TOTAL ROOF AREA s ESCRIPIION: DE! GN: 11.6 KW PV ARRAY Carlos Ang Lora Vow 7.6 KW (AC NAMEPLATE) PV ARRAY SHEET: RED DATE: 2 A 12/13/2022 (N) PV MODULE PV VVIUUUL 5/16"x1.5" BOLT W11 5/16" FLAT WASHE ZEP LEVELING FOO' ZEP ARRAY SKIR- ZEP MOUNTING BLOCi ZEP FLASHING INSER (E) COMP, SHINGLI (E) ROOF DECKIN( 5/16" DIA STAINLESS STEEL LAG SCREW C- DAC-TC-1 k ) N CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR SHALL IT BE DISCLOSED IN MOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WTH THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF TESLA INC, a (E) MOUNTING PLANE (IMP) Im SUBSEQUENT MODULES NI STANDOFF JW NUMBUI: JE3-3351690 00 MOUNTING SYSTEW ZS Como V4 w Flashing —Insert INVERTER: 7.6 kW Teslo Inc 1538000-00—F THIS STRUCTURE ALL RECEIIIJ�E THIS STRUCTURE WTLL RECEIVE LL "U" W DE'7LALBLOCKIUN'G UPGRADE- ADE, _nP4 MP2 ROOF AZI _j ROOF AZI 90 PITCH 23 ffRAFTER2x4 @ 24" OC 270 PITCH 23 RAFTER 2x4 @ 24" OC STORIES: 2 ARRAY AZ 270 PITCH 23 STORIES: 2 ARRAY AZI 90 PITCH 23 .g C.J. 2x4 @24" OC Comp Shingle C.J. 2x4 �@124` OC Comp Shingle F7NSTALLATION ORDER LOCATE RAFTER, MARK HOLE LOCATION, AND DRILL PILOT HOLE. CATTACH FLASHING INSERT TO MOUNTING BLOCK AND ATTACH TO RAFTER USING LAG SCREW. INJECT SEALANT INTO FLASHING (3) INSERT PORT, WHICH SPREADS SEALANT EVENLY OVER THE ROOF PENETRATION. CINSTALL LEVELING FOOT ON TOP (4) OF MOUNTING BLOCK & SECURELY FASTEN WITH BOLT. Likhit Join 7847 Sail Clover Ln Zephyrhills, FL 33540 ffimpm�� (N) STANDOFF SHALL LAG DIRECTLY INTO (N) BLOCKING (N) 2x6 DF#2 OR SPF#2 BLOCKING. (E) JACK TRUSS OR RAFTER (BLOCKING NOT REQUIRED DOWN HERE) (N) SIMPSON A34 CLIPS (2 PER BLOCK) W/ (8) 8d (0,131") X 1-1/2- NAILS PER CLIP (E) SHORTEST BOX TRUSS (BLOCKING FROM HERE UP TO RIDGE AS NEEDED) 11.6 KW PV ARRAY 7,15 KW (AC NAMEPLATE) PV ARRAY PAGE NME: STRUCTURAL VIEWS INSTALLATION NOTES: t CUT (N) BLOCKING TO FIT TIGHT BETWEEN (E) TRUSSES AND KEEP FLUSH TO ROOF SHEATHING. ENSURE THERE ARE NO GAPS BETWEEN MEMBERS. 2, INSTALL (N) BLOCKING WITH TWO A34 CLIPS, ONE AT EACH END OF BLOCKING, 3. NAIL A34 CLIPS TO EXISTING RAFTERS WITH (8) 8D (OA31") X 1.5" NAILS, FILLING ALL HOLES. ENSURE ALL NAILS ARE LOCATED AWAY FROM EDGE OF MEMBERS TO AVOID SPLITTING WOOD, * INSTALL BLOCKING ONLY BELOW STANDOFF LOCATIONS. Carlos Ang Lora SHEET: REV: DATE: 3 A 12/13/2022 Immew T Essw 5 L irm"i ip) )nnt, mAw qFPxAtF- pAmri Voc* = MAX VOC AT MIN TEMP (1 )Ground Roo 5/8' x 8. Copper CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WTH THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT, WTHOUT THE WRITTEN PERMISSION OF TESLA INC. Panel Number: NoMatch Meter Number: 8278744 Underground Service Entrance v i: uu ungrounaea IINV 11- (1) 7.6 kW Tesla Inc 1538000-00-F (24OV) Em R= (1 )SQUARE D 4 HOM240 PV BACKFEED BREAKER Breaker, A/2P, 2 Spaces W - k4�) luwv 31 '-� PV Module, 40OW, 371,5 PTC, 40MM, Black Frame, MC4/MC4-EVO2, ZEP, 1OOOV Voc: 45,3 Vpmax: 37,13 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER MP4: 1x4 MP2: 1x9 ---------- MPI: 1x8 MP3: 1x8 ---------- GIDPlease see MCI wiring detail page for more information A (2)EE-000550-001 MC4 Y-Connector, Receptacle _(2)EE-000550-000 MC4 Y-Connector, Plug PV -(11)Tesla MCI, 650V, 12A No (-, 7 ff (I) AWG #8, THWN-2, Black (1 )AWG #8, THWN-2, Red (2)PV Mre, AM 10 (1) AWG #10, Solid Bare Copper EGC Voc* = 391,75 VDC Vmp = 297.04VDC 15C = 22,28 ADC Imp= 21.54 ADC (2)PV Wire, AM 10 Voc* = 195,88 VDC (1)AM #10, THHN/THYN-2, Green EGG Vmp = 148.52 VDC W3(1)Condult Isc = 11A4 ADC Imp= 10.77 ADC (I)AM #10, THYM-2, Grew EGG Vmp =240 VAC Imp= 32 AAC ( 1 ) Conduit Kit; 3/4' EMT Kit; 3/4' EMT 1 )Conduit Kit; 3/4" EMT F(2)PV Wire, AWG 10 (1) AM 110, Solid Bare Copper EGC Voc* = Vmp =334.17VDC 4-40,72 VDC Isc = 11 A 4 ADC Imp= 10.77 ADC PF(2)PV Wire, AM 10 Voc* = 440.72VDC (1 )AM #10, THHN/THM4-2, Green EGG Vmp =334.17VDC Isc = 1114 ADC Imp= 10,77 ADC (I )Conduit Kit; 3/4" EMT (1)Conduit Kit; 3/4' EMT JOB NUMBER: JE3-3351690 00 MWNTING SYSTEM: ZS Comp V4 w Flashing -Insert MODULES. (29) Teslo # T400H INVERTER: T6 kW Tesla Inc 1538000-00-F (240V) Likhit Jain 7847 Sail Clover Ln Zephyrhills, FL 33540 (2)PV Wire, AWG 10 Voc* = 195,88 VDC Isc = 11.14 ADC (4)PV Wire, AM 10 Voc* = 391,75 VDC Isc = 11A 4 ADC 1) §F (1)AM #10, Solid Bare Copper EGO Vmp =148,52VDC Imp= 10.77 ADC (1 )AM #10, THHN/THWN-2, Green EGC Vmp = 297.04VDC Imp= 10.77 ADC (1) Conduit Kit; 3/4' EMT 1 )Conduit Kit; 3/4' EMT 11,6 KW PV ARRAY 7.6 KW (AC NAMEPLATE) PV ARRAY PAGE NAME; THREE LINE DIAGRAM DESIGN: Carlos Ang Lora SHEET: REV: DATE: 5 A 12/13/2022 (DC) (INV) Per Code: 690.41,B (DC) (CB) Per Code: - 1 Label Location (AC) (POI) Per Code: NEC 690.13.B (AC) (POI) Per Code: NEC 690,54 IMMIRMFUM (AC)(POI) Per Cod& Label Location: (POI) Per Code: NEC 705,12.B.2.3.b (INV) Per Code: LOGaL (D) (POI) Per Code: NEC 690.6413, LaDel LOCal-fuf (POI) Per Code: NEC 705.12 gum (POI) Per •• Label Location: SolarEdge and,Delta M-Series and,Telsa Inverter Per Code: 690.56(C)(1)(a) (AC): AC Disconnect (C): Conduit (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit (INN): Inverter With Integrated DC Disconnect (LC)- Load Center (M): Utility Meter (POI): Point of Interconnection Tesla Solar Inverter AG. o c CO -,m, 'o 1 V 1( C� k-�, E F "S, f ul R E S 0 V; F R E Tesla Solar Inverter Technical Specifications Electrical Specifications: Output (AC) Electrical Specifications: Input (DC) Performance Specifications Output (AC) Nominal Power Maximum Apparent Power Maximum Continuous Current Breaker (Overcurrent Protection) Nominal Power Factor THD (at Nominal Power) MPPT Input Connectors per MPPT Maximum Input Voltage DC Input Voltage Range DC MPPT Voltage Range Maximum Current per MPPT (1,P) Maximum Short Circuit Current per MPPT (1,,) 1534000-xx-y 1538000-xx-y 3.8 kW 7,6 kW 3,800 W 7,600 W 3,328 VA at 208 V 6,656 VA at 208 V 3,840 VA at 240 V 7,680 VA at 240 V 16 A 32 A 20 A 40 A 1 - 0.9 (leading / lagging <5% 2 4 1-2 1-2-1-2 600 VDC 60 - SSO VDC 60 - 480 VDC' 13 A' 17 A 2 MaXIMUM current. Where the DC input current exceeds an MPPT rating, jumpers can be used to allow a single MPPT to intake additional DC current up to 26 A 1,,,, /34 A 1,,-, Peak Efficiency Allowable DC/AC Ratio Customer Interface Internet Connectivity Factory-Insta lied Revenue Grade Meter AC Remote Metering Support Protections Supported Grid Types 98% at 208 V 98,4% at 208 V 98.1% at 240 V 98.6% at 240 V 97.5% at 208 V 97.5% at 208 V 97.5% at 240 V 98.0% at 240 V 1.7 Tesla Mobile App Wi-Fi (2.4 GHz, 802,11 b/g/n), Ethernet', Cellular (LTE/4G) I Revenue Accurate (+/- 0,5%) Wi-Fi (2.4 GHz, 802.11 b/g/n), RS-485 Integrated arc fault circuit interrupter (AFCI), Rapid Shutdown 60 Hz, 240 V Split Phase 60 Hz, 208 V Wye Applicable to Tests Solar Inverter with Site Controller (1538000-4S-y) only. Cellular connectivity subject to network operator service coverage and signal strength. Mechanical Specifications Environmental Specifications Compliance Information Dimensions 660 mm x 411 mm x I58 mm (26 in x 16 in x 6 in) 660 mm �-411 mm 1 mm Weight 52 lb Mounting Options Wall mount (bracket) `' Door and bracket can be removed for a mounting weight of 37 to. Operating Temperature Operating Humidity (RH) Storage Temperature Maximum Elevation Environment Enclosure Rating Ingress Rating Pollution Rating Operating Noise & 1 rn -30'C to 45°C (-22 - F to 11 3'F) Up to 100%, condensing -30°C to 70°C (-22'F to 158°F) 3000 m (9843 ft) Indoor and outdoor rated Type 3R IP55 (Wiring compartment) PD2 for power electronics and terminal wiring compartment, PD3 for all other components < 40 db(A) nominal, < 50 db(A) maximum For the 7.6 kW Testa Solar Inverter, performance may be de -rated in 6.2 kW at 240 V or 5.37 kW at 208 `when operating at temperatures greater than 45'C. Grid Certifications UL 1741, UL 1741 SA, UL 1741 SB, IEEE 1547, IEEE 1547,11 Safety Certifications UL 1741 PVPSS, UL 16998, UL 1998 (US), UL 3741 Emissions EN 61000-6-3 (Residential), FCC 47CFRI5.109 (a) Solar Shutdown Device 1 Technical Specifications Electrical Nominal Input DC Current Rating (1,,d Specifications Maximum Input Short Circuit Current (15,) Maximum System Voltage (PVHCS) RSD Module Maximum Number of Devices per String Performance Control Passive State Maximum Power Consumption Warranty Environmental Ambient Temperature Specifications Storage Temperature Enclosure Rating Compliance Certifications Information RSD Initiation Method Compatible Equipment M 5 Power Line Excitation Normally Open 7 W 25 years -40°C to 50°C (-40°F to 122°F) -30°C to 70°C (-22°F to 158°F) NEMA 4X / IP65 UL 1741 PVRSE, UL 3741. PVRSA (Photovoltaic Rapid Shutdown Array) PV System AC Breaker or Switch See Compatibility Table below A Mechanical Model Number MCI-1 �8 Specifications Electrical Connections MC4 Connector 250 mm 119 Housing Plastic M4 Screw Dimensions 125 mm x 150 mm x 22 mm 650 mm 150 mm CM8 Bolt (5 in x 6 in x I in) Weight 350 g (0.77 lb) Nail Wood Screw Mounting Options ZEP Home Run Clip ------ ------- M4 Screw (#10) M8 Bolt (5/16") Nail / Wood screw H I FRI 22 mm 125 rnm-� UL 3741 PV Hazard Control (and PVRSA) Compatibility Testa Solar Roof and Tesla/Zep ZS Arrays using the following modules are certified to UL 3741 and UL 1741 PVRSA when installed with Testa Solar Inverter and Solar Shutdown Devices. See �esjo, St r u, 'dO iez.'ar_Con-rol Systcni i -L,,, for guidance on installing Testa Solar Inverter and Solar Shutdown Devices with other modules. Brand Model Required Solar Shutdown Devices Testa Solar Roof V3 I Solar Shutdown Device per 10 modules Testa Testa TxxxS (where xxx = 405 to 450 W, increments of 5) 1 Solar Shutdown Device per 3 modules Tesla Testa TxxxH (where xxx = 395 to 415 W, increments of 5) 1 Solar Shutdown Device per 3 modules Hanwha aPEAK DUO BLK-GS or Q.PEAK DUO BLK-G6+ I Solar Shutdown Device per 3 modules Exceptiom Testa solar modules installed in locations where the max Voc for three modules al low design temperatures exceeds 165 V shalj be limited to two modules between Solar Shutdown Devices. Module Specifications Electrical Characteristics r-1 Mechanical Loading Mechanical Parameters Operation Parameters Linear Power Warranty IV Curves SPECTICAT�ONS Desigvierl Ws, Engmeered NN spanS up 10 72 st cavUlves jp to 24' ZS COMP "S a UL 1703 AFin Ralungvvhen WANd unng madules fronn ami !nw whown ceMQd au Tpe V "'Ype 2 nnethod UL 2582 for D6,,.,e?,-,, Pain, ZS Comp s4qwts 50 pet (24C)C PO� from and up lo 72 psf -,,,345�,.,, Pa; rew side design loac, r,at;r,,g fo, Porlra�t mc-PdWe ventmen p, LK 270,-,, ZS Comp tu-iptp,:-,r�s 50 psf Q40C Pa! Now ode md up ic 72 psf 2450 Pal mar Ode deng,-. ioad ratir-,-c fic,)f Landscane nricjdOe one�-Oat�on, Erngmeued hy vvE 7-15, 7M and 7 Zw-, ,v�e ri-,@-�ager-it-n-1, fistec tc., ji-, 1`5"75 for ZS Comp gmwlmg yxodwts we bsed ic Ul 2703 and UL 467, A Comp MnIng , .;,re ---------- The Tesla Retrofit PV assembly does not exceed 3.5psf. Installation of the Tesla Retrofit PV assembly offsets load in areas of the roof designed to support a roof live load and provides a lower -friction surface than the existing roof. The weight of the offset live load or difference in accumulated roof snow load as a result of reduced surface friction (in regions where the roof snow load is greater than the roof live load) will exceed the weight of the PV assembly. Consequently, the net additional loading impact to existing gravity load resisting elements is less than 5% for the framing of pitched roof structures with existing roofing material comprised of comp shingle or tile. Note that this assessment does not apply to structures with existing metal roof coverings in regions where roof snow load is greater than roof live load. THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED 8v HENRY ZHU, PEON 09/00/2021 PRINTED COPIES DFTHIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST REVERIFIED Henry Zhu, P.E. Civil EnQineer, Tesl@ yonzhu@tes|a.00nn ~�~ �� �� N Fi Te�u,|nc