HomeMy WebLinkAbout23-5780WV779MMA,1, �,Ng 5335 Eighth Street Zephyrhills, FL 33542 Phone: (813) 780-0020 Fax: (813) 780-0021 FIRE-005780-2023 Issue Date: 03/23/2023 REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. 23131i�� VW7'Mlvm� accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. ( '7 CONTRACTOR SIGNATURE PE IT OFFICE '*ERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER I GENERAL NOTES DATE I BY IREV I DESCRIPTION SYMBOL VIKING MICROFASTVK302 STANDARD COVERAGE QUICK RESPONSE PENDENT (RECESSED ESCUTCHEON) SIN# VK302 PCU SPRINKLER LEGEND SYMBOL COUNT K-FACTOR SIN NPT DESCRIPTION Oi 47 5.6 VK302 %Z' VIKING MICROFAST CIR WHITE RECESSED PENDENT FIRE SPRINKLER HEAD 155° DENOTES EXISTING FIRE SPRINKLER HEAD TO BE RELOCATED ® DENOTES EXISTING FIRE SPRINKLER HEAD 47 TOTAL HEADS DENOTES EXISTING FIRE SPRINKLER PIPE TO DEMO EEC EEC DENOTES EXISTING FIRE SPRINKLER PIPE TO REMAIN DENOTES NEW FIRE SPRINKLER PIPE DENOTES CONNECTION POINT TO EXISTING FIRE SPRINKLER SYSTEM SPRINKLER LEGEND STEEL BAR JOIST CAD PLATED FERROUS ALL -THREAD ROD SEE MINIMUM SIZE NOTE: BULK HANGER MATERIAL HAS BEEN SENT TO THEJOBSITE. FIELDCUT HANGERS AS NECESSARY. ALL THREAD ROD SIZES PIPE SIZES 1"- 4" - ROD SIZE = 3i3" PIPE SIZES 5" - 8" - ROD SIZE = 1/2" PIPE SUPPORT -TYPE S01 TOP BEAM CLAMP W/ RING HANGER .DROP -IN' TYPE ANCHOR IN CLEANLY DRILLED HOLE (HILTI HDI ORUL USTED EQUIVALENT) HILTI SIZES LISTED BELOW 3I3" CAD PLATED UL LISTED SWIVEL RING HANGER — PIPE ALL THREAD ROD SIZES PIPE 5IZE51'-4"-RODSRE=1 - PIPESIZESJ -8'-ROD SIZE=1r2' PIPE SUPPORT - TYPE C01 DROP -IN ANCHOR W/ RING HANGER METAL DECK SPAT UL LISTED 5WNN Fur PIPE SUPPORT SAMMY EXPRESS FOR STEEL W/ RING HANGER SAI.LMY SUPER SCREW FOR 1/4" PRE-DRILL'cD CONCRETE, CST 20 (FM H4'PRE-O LE IN RiLLED E APPROVED FOR PIPE SIZES —� UP 70 4") NOTE: 3/3- GAD PLATED FERROUS BULK HANGER MATERIAL HAS BEEN ATR SENT TO THEJOBSITE. FIELD CUT HANGERS AS NECESSARY. UL LISTED SNIVEL RING HANGER 4{r PIPE PIPE SUPPORT SAMMY SUPER SCREW FOR CONCRETE W/ RING HANGER HANGER SPACING TABLE PIPE SIZE SCH. 10-40 V. 1 '4 1 Z" 2" 2 2" 3" 4" 6" 8" MAXIMUM HANGER SPACING 12'-0" 12'-0" 15'-01, 15'-0" 15'-0" 15'4" 15'-0" 15'-0" 15'-0" CPVC (IF APPLICABLE) 1" 1 T. 1 2" 2" 2 2' 3" 4" 6" 8" MAXIMUM HANGER SPACING 6'-0" 6'-6" 7'-0" 8'4" 1 9'-0" 10'-0" 10'-0" 1 NA NA HANGER DETAIL 2'-OO o 1' 0" V-0" O O O O FIRE SPRINKLERHEAD FIRE SPRINKLER HEAD SPACING ON SPACING ON 2' x 4' CHUNG TILE 2' x 2CEILING TILE SI LLLL BE QUARTER TILE SHALL BE CENTER TILE FIRE SPRINKLER CEILING TILE PLACING Sy'—Na l'7{-1G5J F R2tin,-1 aM 2 Nr(ke hz,ns 1 aid 3) T dating-BIV LRaling Ar Aanlient-Less rh>'r I Cf nvsq ft !ftddngPt4:fJ F-4 CHM1ti5q ft SIC110NAA I. WatlASTemcly-i tor2fv Di-rv;2o 2JP5U11'ca"Ll 'y X.tiI aSSPJrblyuaNV(9nsWR?d 0I rre materiak and N V•4', marvu=.penfxim ue ur-nrdrl VYA or WOB Su:esYlaY and Fan:Bon Cesiytt d'e UL Fu=. Resistirxe D1eu«/and shatl include me FcYvwirg•onsuxdon Feanx=s: A Rudd- YJaY Franun+may ronsi5t of conu om 2v64rt1 e6 th OCS11 des1 STLdl msteteol.021Rlsliundsndl saos to and �e edm 24 in'moph' Le h� dare usedandm,diatn ofcvvenir.%% w ,e lle wiem e ,e cl iUlte[y�eningshallbe GamedoeaYsidesusing Ixngchsofsleelswd instilled berneen tie enlcal studs andwewanarrzd m tiesteelst at each end. mefra"xlepening in the ndtl shall b i4 m Bia hider acd 4m S in. hJgherman the dum of ve Txnevadr�g hem d,:mmar, n'rrn me perteuaGng itcrn is imtilled H me opening a t tv 3 in Uearsrxe is Prserrt cenveen me atircg tom aM VK framing on atl lair sties. B�xGypsum Board'-Yd in dix, 3 R nrde .v�[h sgcue «capered e<+=es ine °)plum board r�v dScsress counter cf la)as, Fsserar raga aM st ercren[auan shall%as spewed m me nGndiul U3C0«U4G057�e5 Cesgn N me lLFue Banance W eeory. V.ax damofopen;rg i532 V4 in for sceU and netls..g>zxdiamof cpen'v�gls :11R I" Ta wood snd natls. lyre FParvgcf dre Fuescp synem s aqual rorbe fire rzfingolrrK natl assemcff. E= ,C:EF3Q8 ddycedb Hit Inc [Pu of U�-.,,moo FIRESTOP SYSTEM" P.ep� LF%mE-r i,�x C®U5 Paged Of ALL THREAD ROD 3/8" OR 1/2" SCHEDULE 40 UROP NIPPLE w11.'ki' REDUCER U.N.O. SEE FLOOR PLAN FOR ARM -OVER LENGTHS \\\ FINISHED CEILING RECESSED ESCUTCHEON ARM -OVER / RETURN BEND DETAIL _ztan No.W'L-ICu-" F Raw., - I and 2 FuJSee L-1"3) T Rating-0 Hr L W&AtArI U.1-Tess l Vas 10 WSq R L.W& At 4E9 F. 4 CFA✓SgR �� Rep�a�red b�R�n.l CevHes�of C�f' , FIREACPMTENS r9pembe�4.'{�' US P-e:20f TOP BEAM CLAMP 318" OR 1/2" 7�jm �TOP HANG- ER j HAIL BLACK SCH. 10 OR 40 PIPk `E 1" FIRE SPRINKLER SYSTEM PIPE ALL THREAD ROD 3/8" OR 1/2" HANGER RING TRAPEZE SCHEDULE PIPE SIZE TRAPEZE DIAMETER TRAPEZE TYPE ROD SIZE TOP HANGER BOTTOM HANGER MAX SPAN 6" 4" SCHED 10 12" 4" o" 4" 3" SCHED 10 3/8" 3" 4" 10'-0" 2.5" 2.5" SCHED 10 3/8" 2.5" 2.5" 10'-0" 2.5" 2" SCHED40 3/8" 2" 2.5" 6'-0" 1.25" 2" SCHED40 3/8" 2" 1.25" 9'-0" 1.25' 1.5" SCHED40 3/8" 1.5" 1.25" 51-0" 1.25" 1.25" SCHED 40 3/8" 1.25" 1.25" 4'-0" 1" 2" SCHED 40 3/8" 2" 1" 10'-0" 1" 1.5" SCHED 40 3/8" 1.5" V. 5.4. 1" 1.25" SCHED 40 3/8" 1.25" 1" 4'-0" 1" 1" SCHED 40 3/8" 1.. 1" 2'-0" PCU FIRE SPRINKLER PLAN SCALE: 1 /8" = 1'-0" SCALE 1/8"=V-0" FIRE SPRINKLER DRAWING LEGEND SYMBOL DESCRIPTION 3" < PIPE SIZE 10-6 PIPE LENGTH IN FEET -INCHES 0 HYDRAULIC REFERENCE POINTS [18 Bc] ELEVATION BELOW TOP OF STEEL [ 8-6] ELEVATION ABOVE FINISHED LFOOR + (TOS 20-o) ELVEATION OF TOP OF STEEL o-o CEILING HEIGHT DENOTES HANGER LOCATION ® up 1 x 1-0 DENOTES RISE UP OR DOWN STANDARD GROOVED COUPLING © FIRELOCK GROOVED COUPLING [- PIPING CAP { PIPING PLUG ® FIRE SPRINKLER RISER LOCATION # 1_01 LINE TAG (IF STOCK LISTED) a In A. 1 MAIN TAG (IF STOCK LISTED) BASIC PIPE & FITTING MATERIAL REQUIREMENTS MINIMUM PIPE SCHEDULE FOR WELD/GROOVED/PLAIN END PIPE SCH. 7(DYNAFLOW, ETC.) BLACK STEEL PIPE SCH. 10 GALVANIZED PIPE SCH. 40 SEAMLESS SCH. 80 SHOP PAINTED CPVC MINIMUM PIPE SCHEDULE FOR THREADED PIPING: THREADABLE LIGHTWALL BLACK STEEL PIPE 17 SCH. 40 GALVANIZED PIPE SCH. 80 SEAMLESS SHOP PAINTED FITTINGS GROOVED (STANDARD TAKEOUT) C.I. SCREWED GROOVED (SHORT RADIUS) D.I. SCREWED GROOVED COUPLINGS (RIGID) M.I. SCREWED (BLACK) GROOVED COUPLINGS (FLEXIBLE) M.I. SCREWED (GALV) WELDED OUTLETS FLANGED 125# 1/1 M ECHAN ICAL TEES FLANGED 250# CPVC HANGER MATERIAL STANDARD LOOP HANGER RINGS CLEVIS HANGERS REQUIRED ALL THREAD ROD TO BE BLACK 17 ALL THREAD ROD TO BE CAD PLATED STAINLESS HANGER MATERIAL REQUIRED MATERIAL REQUIREMENTS DOMESTIC MATERIAL ONLY DOMESTIC OR FOREIGN MATERIAL ACCEPTABLE MATERIAL TO MEET THE MINIMUM REQUIREMENTS OF NFPA 13 MATERIAL TO BE UL LISTED AT A MINIMUM MATERIAL TO BE UL LISTED & FM APPROVED DRAIN PIPE & FITTINGS TO BE GALVANIZED GALVANIZED PIPE & FITTINGS REQUIRED FOR EXTERIOR WALL PENETRATIONS & EXTERIOR PIPING RUNS 2257B 1I 2258E 2259E 2260E SCOPE OF WORK: TO DESIGN AND RETROFIT THE FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA 13, 2016, IN ACCORDANCE WITH FFPC 7TH ED. AND LOCAL AUTHORITY. BUILDING HAS AN OPERATIONAL FIRE SPRINKLER SYSTEM. WORK CONSISTS OF RELOCATION EXISTING SPRINKLERS TO NEW ROOM LAYOUT, AS SHOWN ON PLANS. NAME OF OWNER: ADVENT HEALTH AREA OF WORK: 4,397 SQ. FT. 1. ALL UNDERGROUND PIPING IS EXISTING TO REMAIN AS IS UNDISTURBED. 2. 1" TO 2" PIPING MAY BE BLACK SCHEDULE 40 THREADED AND JOINED BY DUCTILE IRON FITTINGS AND COUPLINGS. 3. 121" TO 611 PIPING MAY BE SCHEDULE 10 ROLL GROOVED AND JOINED BY GROOVE TYPE FITTINGS. 4. ALL HANGERS AND TRAPEZE ASSEMBLIES SHALL UTILIZE UL/FM LISTED COMPONENTS AND COMPLY WITH NFPA 13 REQUIREMENTS. 5. ALL CONTROL VALVES ARE EXISTING TO REMAIN AS IS UNDISTURBED. 6. INSTALL PENDANT SPRINKLER HEADS IN CENTER OF THE CEILING TILE. 7. MIC (MICRO -BIOLOGICALLY INFLUENCED CORROSION) IS NOT KNOWN TO BE A PROBLEM AT THIS LOCATION. 8. MODIFICATIONS DO NOT INCREASE THE HYDRAULIC DEMAND OF THE EXISTING SYSTEM, NO HYDRAULIC CALCULATIONS ARE INCLUDED. /vj-� F(rp;-)S AHJ APP. zW O U Q m U U fV N E z~zo°� O 0-1 O U� V)0�'`�x cr LL ��— WJ000 '�Lu zw Q LL O unx �<� zp M U z O > z F� 0Z � J �� JwOc� t� Q>J DC LLI m L w 0 -iz _ U) � � U)J tu Q J z �_LIJu_ xo _ o � Q ZU©_ cll� Lk w (I) Lo r2 > _j Ao } 1 0 = W w Q Nry LL U CL w w o N BARTON MALOW CONTRACT NO. 1-1-4141-10-22 APPROVAL A.H.J. DESIGNER NSC SCALE AS NOTED DATE 11 /4/2022 FP1