Loading...
HomeMy WebLinkAbout23-5941=1 W, MIMM, � 5335 Eighth Street Zephyrhills, FL 33542 Phone: (813) 780-0020 Fax: (813) 780-0021 III III PIII 111111, R 11111! 11 11 SL-005941-2023 Issue Date: 04/05/2023 Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in dance City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. N CTOR SIGNATURE PE IT OFFICE PERMI EXPIRES IN MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED IN, FINUTETIZE11129 GENERAL ELECTRICAL SPECIFICATIONS 1. THE ELECTRICAL CONTRACTOR REFERRED TO HEREAFTER, AS THE "CONTRACTOR" SHALL PROVDE COMPLETE ELECTRICAL SYSTEMS AS INDICATED ON THE DRAWINGS AND SPECIFIED HEREIN. 2. CONTRACTOR SHALL PROVIDE PROTECTIVE DEVICES, CONDUCTORS, SUPPORTS, RACEWAYS, ANDMISCELLANEOUS MATERIALS TO SERVE ALL DEVICES REQUIRING ELECTRICAL POWER. 3. CONTRACTOR SHALL OBTAINAND PAY FOR ALL PERMITS, FEES, AND INSPECTIONS REQUIRED TO COMMENCE AND COMPLETE ELECTRICAL WORK. 4. CONTRACTOR SHALL CONDUCT A THOROUGH SITE INSPECTION TO FAMILIARIZE HIMSELF WITH ElISTING CONDITIONS AND ALL ASPECTS OF HIS SCOPE OF WORK. SUCH All INSPECTION SHALL BE CONDUCTED PRIOR TO SUBMITTING A BID. 5. ALL WORK SHALL BE PERFORVIED DURING PERIODS ACCEPTABLE TO THE OWNER. SCHEDULE ALL \VORK WITH THE OWNER'S REPRESENTATIVE BEFORE PFOCEEDING. 6. AT PROJECT COMPLETION, THE CONTRACTOR SHALL INSURE THAT ALL ELECTRICAL SYSTEMS OPERATE PROPERLY. CONTRACTOR SHALL DEMONSTRATE OPERATION OF EACH SYSTEM WITH THE OWNER'S REPRESENTATIVE. 7. CONTRACTOR SHALL COORDINATE AND VERIFY WITH LOCAL POWER COMPANY THE FOLLOWING: - EXACT LOCATION OF SERVICE CONNECTION - ELECTRICAL CHARACTERISTICS (VOLTAGE AND PHASING) - AVAILABLE FAULT CURRENT - METERING REQUIREMENTS 8. "PROVIDE" SHALL MEAN "FUR141SH AND INSTALL". CODES AND STANDARDS 1. ELECTRICAL WORK HAS BEEN DESIGNED TO AND SHALL COMPLY WITH: - NFPA 70 2017 (NATIONAL ELECTRICAL CODE) - NFPA 72 2016 (NATIONAL FRE ALARM & SIGNALING CODE) - FBC 2020 7TH EDITION - NFPA 101 (LIFE SAFETY CODE) - FLORIDA FIRE PREVENTION CODE. - CODES SPECIFIC TO OTHER SECTIONS HEREIN 2. ELECTRICAL WORK SHALL COMPLY WITH ALL LOCAL AND STATE ELECTRICAL CODES AND IN ACCORDANCE WITH REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION (AHJ). QUALITY 1. WORKMANSHIP SHALL BE HIG'-I QUALITY AND FOLLOW INDUSTRY STANDARDS. SUBSTANDARD \VORK WILL BE REJECTED, THE CONTRACTOR IS RESPONSIBLE FOR REPAIR AND REWORK TO RECTIFY SUBSTANDARD WORK. QUALITY OF WORK SHALL BE DETERMINED BY THE OWNER'S REPRESENTATIVE AND/OR ENGINEER OF RECORD_ MATERIALS 1. ALL ELECTRICAL EQUIPMENT AND MATERIALS SHALL BE NEW AND APPROVED BY UNDERWRITERS LABORATORY FOR THE APPLICATION AND SHALL BEAR A UL LABEL. 2. ELECTRICAL ENCLOSURES SHALL BE NEMA RATED. UNLESS OTHERWISE NOTED, ENCLOSURE RATINGS SHALL ADHERE TO THE FOLLOWING: - NEMA1 INDOOR - NEMA 3R OUTDOOR - NEMA 4 CORROSIVE ENVIRONMENT GUARANTEE 1. CONTRACTOR SHALL GUARANTEE ALL WORK FOR A PERIOD OF ONE YEAR FROM DATE OF OWNERS ACCEPTANCE. THE CONTRACTOR SHALL ELECTRICAL SPECIFICATIONS RECTIFY ANY DEFECTS DUE TO FAULTY MATERIALS OR WORKMANSHIP AND PAY FOR DAMAGE CAUSED BY FAILURE AND REWORK, THE OWNER WILL GIVE NOTICE OF DEFECTS WITH REASONABLE PROMPTNESS AFTER DISCOVERY. THE CONTRACTOR SHALL START REWORK WITHIN TEN (10) WORKING DAYS OF NOTIFICATION AND COMPLETE REPAIRS IN A TIMELY MANNER. IDENTIFICATION OF EQUIPMENT 1. LABEL ALL ELECTRICAL EQUIPMENT WITH ENGRAVED LAMINATED PLASTIC NAMEPLATE THAT CLEARLY DESCRIBES THE EQUIPMENT NAME, VOLTAGE, AMPERAGE RATING, AND FUNCTION. NAMEPLATES SHALL BE BLACK BACKGROUND WITH WHITE STENCILED UPPER CASE LETTERING A MINIMUM OF 3/16" IN HEIGHT. USE RED BACKGROUND FOR EMERGENCY SYSTEMS. 2. INSTALL VINYL CLOTH SELF-ADHESIVE CIRCUIT LABELS ON ALL WIRE AND CABLE IN JUNCTION BOXES, WIRE TROUGHS, AND PANELBOARD WIRING GUTTERS. 3. IDENTIFY JUNCTION BOXES WITH PERMANENT MARKER INDICATING PANELBOARD AND CIRCUIT NUMBERS OF WIRING CONTAINED WITHIN. 4. PROVIDE TYPEWRITTEN PANELBOARD DIRECTORIES WITH ACCURATE AS BUILT INFORMATION. DIRECTORIES SHALL REFLECT TYPE OF LOAD AND AREA SERVED FOR EACH BREAKER. RACEWAYS AND FITTINGS 1. CONDUIT SHALL BE PROPERLY ALIGNED, GROUPED AND SUPPORTED. EXPOSED CONDUIT SHALL BE INSTALLED AT RIGHT ANGLES TO OR PARALLEL TO THE PRINCIPAL STRUCTURAL MEMBERS. CONDUIT SHALL BE SUPPORTED AT INTERVALS NOT EXCEEDING 8 FEET. CONDUIT SHALL BE SUPPORTED FROM STRUCTURE AND NOT FROM CEILING SUPPORT SYSTEM. 2. FLEXIBLE METALLIC CONDUIT IN DAMP OR WET LOCATIONS SHALL BE UNDERWRITERS' APPROVED, GALVANIZED STEEL WITH MOISTURE PROOF PVC JACKET. FITTINGS SHALL INSULATED THROAT AND LIQUID TIGHT AS MANUFACTURE BY THOMAS AND BETTS, OR APPROVED EQUAL. 3. GALVANIZED RIGID STEEL (GRS) CONDUIT SHALL BE UL APPROVED HOT DIPPED GALVANIZED. GRS CONDUIT COUPLINGS SHALL BE THREADED HEAVY WALL GALVANIZED STEEL. USE 90 DEGREE GRS SWEEPS AND GRS RISERS IN UNDERGROUND PVC CONDUIT RUNS. PAINT ALL GALVANIZED RIGID CONDUITS INSTALLED BELOW GRADE WITH RUST INHIBITING PAINT. 4. PVC CONDUIT SHALL BE UL LISTED SCHEDULE 40 PVC UV RESISTANT. PVC CONDUIT MAY BE ONLY BE UTILIZED WHEN ENCASED IN NOT LESS THAT 2" OF CONCRETE. NOTE THAT WHILE PORTIONS OF THE BUILDING ARE CLASSIFIED AS ASSEMBLY, THIS REQUIREMENT APPLIES TO ALL AREAS. BOXES 1. BOXES SHALL BE RIGIDLY MOUNTED AND COVERED WITH MATCHING PLATE. OPEN KNOCK -OUTS OR HOLES IN BOXES SHALL BE PLUGGED WITH A SUITABLE BLANKING DEVICE. 2. SURFACE MOUNT EXTERIOR OUTLET BOXES SHALL BE CAST ALUMINUM WITH WEATHERPROOF ALUMINUM GASKETED COVER. 3. FLUSH MOUNT EXTERIOR OUTLET BOXES SHALL 4" SQUARE STEEL WITH MASONRY RING AND WEATHERPROOF GASKETED CAST ALUMINUM COVER. CONDUCTORS 1. SPLICES AND TAPS SHALL UTILIZE SOLDERLESS LUGS FOR #8 AWG AND LARGER. SPLICES AND TAPS SHALL FORM A ELECTRICAL AND MECHANICALLY SECURE CONNECTION. LUGS SHALL BE CORRECTLY SIZED FOR THE CONDUCTORS. TAPE JOINTS WITH VINYL PLASTIC ELECTRICAL TAPE, 2. ALLOW SUFFICIENT CABLE SLACK IN BOXES, OUTLETS AND CABINETS TO MAKE CONNECTION AND INSURE THERE IS NO BINDING AT THE SPLICE/TAP. 3. CONDUCTORS SHALL BE COPPER. UNLESS OTHERWISE NOTED, INSULATION SHALL BE DUAL TYPE THHN/THWN 75°C. CONDUCTORS SHALL BE COLOR CODED IN ACCORDANCE WITH NFC 70. COLOR CODING SHALL BE BY MEANS OF COLORED INSULATING MATERIAL, COLORED BRAID OR JACKET OVER THE INSULATION OR BY MEANS OF SUITABLE COLORED, PERMANENT, NON -AGING, INSULATING TAPE APPLIED TO CONDUCTORS AT EACH CABINET OR JUNCTION POINT. THE FOLLOWING SYSTEM OF COLOR CODING SHALL BE ADHERED TO: - GROUND LEADS: GREEN - 120/240 NEUTRAL CONDUCTOR: WHITE - 120/240 VOLT, PHASE CONDUCTORS: BLACK, RED, BLUE 6. THE COLOR CODE ASSIGNED TO EACH PHASE WIRE SHALL BE CONSISTENTLY FOLLOWED THROUGHOUT. GROUNDING 1. ALL ELECTRICAL SYSTEMS SHALL BE COMPLETELY AND EFFECTIVELY GROUNDED AS REQUIRED BY NFPA 70 AND AS SPECIFIED HEREIN. 2. METALLIC RACEWAYS SHALL BE MECHANICALLY AND ELECTRICALLY SECURE AT ALL JOINTS AND AT ALL BOXES, CABINETS, FITTINGS, AND EQUIPMENT. METALLIC RACEWAYS SHALL BE CONNECTED TO A DIRECT GROUND AT POINT OF ELECTRICAL SERVICE ENTRANCE AND SHALL BE ELECTRICALLY CONTINUOUS THROUGHOUT THE ENTIRE SYSTEM. 3. ALL GROUND CONDUCTORS SHALL BE INSULATED COPPER UNLESS OTHERWISE NOTED. 4. RACEWAYS WITH NO. 10 OR 12 AWG PHASE CONDUCTORS FOR RECEPTACLES, LIGHT FIXTURES AND SIMILAR CIRCUITS (NEW BRANCH CIRCUITS) SHALL BE PROVIDED WITH A PARITY SIZED GREEN EQUIPMENT GROUND CONDUCTOR. GROUND CONDUCTOR SHALL BE INSTALLED IN ENTIRE RACEWAY SYSTEM INCLUDING WALL SWITCHES AND FLEXIBLE CONDUIT TO LIGHT FIXTURES, WIRING DEVICES 1. LIGHTING TOGGLE SWITCHES SHALL BE 20 AMP, SPECIFICATION GRADE TOGGLE TYPE SWITCHES. ALL SWITCHES AND COVERPLATES SHALL BE GRAY. ALL COVER PLATES SHALL BE WEATHERPROOF. 2. DUPLEX RECEPTACLES SHALL BE 20 AMP, 125 VOLT RATED, SPECIFICATION GRADE. RECEPTACLES SHALL HAVE A GREEN GROUNDING SCREW TERMINAL AND A SELF GROUNDING CLIP. ALL RECEPTACLES SHALL BE GRAY WITH WEATHERPROOF COVER PLATES. GFC1 TYPE RECEPTACLES SHALL BE 20 AMP 125V, NON FEED-THRU TYPE. 1. PANELBOARDS SHALL BE EQUIPPED WITH COPPER BUS, 98% CONDUCTIVITY, CIRCUIT BREAKERS SHALL BE OF THE BOLT -ON TYPE, SERIES CONNECTED AIC RATINGS SHALL BE ACCEPTABLE AS PER MANUFACTORER'S UL SERIES CONNECTED RATINGS DATA. ACCEPTABLE MANUFACTURERS: SQUARE-D, EATON, GE, SIEMENS. SURGE PROTECTION DEVICES 1. SPD UNITS SHALL BE OF THE MODULAR DESIGN TYPE WITH FUSES RATED AT 100 KAIC, INTEGRAL DISCONNECT SWITCH, RED AND GREEN LED'S FOR POWER AND PROTECTION STATUS. UL1449, 3RD EDITION CLAMPING VOLTAGE FOR WYE CIRCUITS AS FOLLOWS: LINE TO NEUTRAL: 40OV. - LINE TO GROUND: 40OV. - NEUTRAL TO GROUND: 40OV. LUMINAIRE SCHEDULE TYPE DESCRIPTION / MANUFACTURER / MODEL NUMBER VOLTAGE WATTS LAMP(S) LUMENS MOUNTING NOTES A FLOODLIGHT/ LITHONIA/ ESXFI-PO-SWW2-THK-DDB 120V 17W LED 2500L KNUCKLE MOUNTING PLATE PROVIDE WITH INTEGRAL PHOTO CONTROL PANEL "SL" SQUARE D: NQ 240/12OV, 10, 3W VOLTAGEIPHASE IOOA MCB 100A BUS NEMA-3R SURFACE 10,000 AIC FULLY RATED COPPER BUS 8DLID NEUTRAL CKT AMPS POLE DESCRIPTION NOTES LOAD VA CKT AMPS POLE DESCRIPTION pDTES LOAD VA 1 20 1 MONUMENT SIGN 1200 2 20 1 RECEPT 180 3 20 1 SPACE 1 0 4 20 2 SPD 0 5 20 1 SPACE 0 6 0 NOTES: LOAD CONNECTED DESCRIPTION LOAD (VA) DEMAND FACTOR DEMAND LOAD;VA) 1. LIGHTING 1,200 HVAC - COCA. 0 HVAC - HEAT 0 RECEPTACLE 180 MISC 0 1.25 0.00 0.00 1.00 1.00 1,5M 0 0 180 0 2. 3, 4, 5. 6. TOTAL 1,380 1,68b 7. TOTAL DEMAND CURRENT@ 2401120V, 10 7.0 AMPS GRADE UTILITY 0 RISER KEYNOTES 1. EXISTING UTILITY PAD MOUNTED TRANSFORMER. COORDINATE SERVICE CONNECTION WITH UTILITY COMPANY. 2. PROVIDE (3) #1 AL, IN 1 1/4" CONDUIT. 3. PROVIDE COMBINATION METER / PANELBOARD. 100A / 240V / 10 IN NEMA-3R ENCLOSURE. REFER TO PANEL SCHEDULE FOR ADDITIONAL INFORMATION. MOUNT TO SIDE OF MONUMENT SIGN. COORDINATE WITH GENERAL CONTRACTOR. REFER TO PARTIAL SITE PLAN FOR SPECIFIC LOCATION. GFI WP MONUMENT PANEL SIGN SL' 6,90? AFC 1oaA MCB 1201240V EXISTING 3W, 10 PAD MDUNTED 1 TRANSFORMER O 25KVA 120/24OV.10 METER 0 <10,000 AFC 10,000 AFC #8 CU GEC VICINITY MAP � ELECTRICAL RISER DIAGRAM SGALE'. NTS S:nLE'. NTS r PARTIAL SITE PLAN E-1 SCALE: 1" = 20'-0" ELECTRICAL LEGEND SYMBOL DESCRIPTION MOUNTING In BRANCH CIRCUIT PANELBOARD, 120/240 V, SURFACE MOUNT 72" AFF TO TOP 8 ELECTRIC METER 60" AFF TO TOP w 17 FLOOD LIGHT KNUCKLE MOUNT DUPLEX RECEPTACLE, 20 A, 120 VAC 18" AFF TO CENTERLINE UNLESS NOTED OTHERWISE P1.1.3 HOMERUN TO PANELBOARD. ALL CONDUCTORS ARE #12 AWG Cu UNLESS NOTED OTHERWISE. RACEWAY CONCEALED UNDER FLOOR OR BELOW GRADE ABBREVIATIONS AFF ABOVE FINISHED FLOOR BFG BELOW FINISHED GRADE WR WEATHER RESISTANT AFG ABOVE FINISHED GRADE EX EXISTING UG UNDERGROUND AHJ AUTHORITY HAVING JURISDICTION GFI GROUND FAULT CURRENT INTERRUPTER UNO UNLESS NOTED OTHERWISE WP WEATHER PROOF I t (I 4i LQ 1 n J Cy Qr 1 LZI GENERAL NOTES 1. THE CONTRACTOR SHALL REFER TO THE ELECTRICAL SPECIFICATIONS FOR ADDITIONAL DESIGN STANDARDS. THE ELECTRICAL SPECIFICATIONS ARE A BINDING PART OF THE CONSTRUCTION DOCUMENTS. 2. ALL MATERIALS USED FOR CONSTRUCTION SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER. RACEWAY AND CABLES SHALL RUN PARALLEL OR PERPENDICULAR TO WALL AND CEILING STRUCTURES FOR A NEAT APPEARANCE. ALL MATERIAL AND INSTALLATION WILL BE SUBJECT TO OWNER'S APPROVAL. COORDINATE AND SCHEDULE INSPECTIONS WITH THE AHJ AND THE OWNER ACCORDINGLY. 3. SYMBOLS NOT LISTED IN THE LEGEND ARE IDENTIFIED WHERE THEY OCCUR ON THE DRAWINGS. 4. PRIOR TO ANY EXCAVATION, THE CONTRACTOR SHALL CONTACT THE UTILITY COMPANY AND HAVE EXISTING UNDERGROUND UTILITIES SURVEYED AND INDICATED. 5. ELECTRICAL DRAWINGS ARE DIAGRAMMATIC ONLY. FURNISH ALL REQUIRED JUNCTION BOXES, PULL BOXES, FITTINGS, CONDUIT BODIES, SUPPORT, ACCESS DOORS, HARDWARE, ACCESSORIES, ETC. REQUIRED FOR A COMPLETE AND WORKING ELECTRICAL SYSTEM, WHETHER OR NOT SUCH EQUIPMENT IS INDICATED ON THE DRAWINGS. 6. THE CONTRACTOR SHALL COORDINATE WITH ALL CONTRACT DOCUMENTS AND EQUIPMENT SHOP DRAWINGS. 7. THE CONTRACTOR SHALL COORDINATE HIS WORK WITH ALL OTHER TRADES BEFORE INSTALLATION OF HIS WORK IN AREAS WHERE CONFLICT MAY OCCUR. 8. ALL ELECTRICAL EQUIPMENT SHALL BE NEW AND LISTED AND LABELED UNDERWRITER'S LABORATORY (U.L.). 9. PROVIDE DEDICATED NEUTRAL WIRES FOR ALL BRANCH CIRCUITS U.N.O. 10. WHERE THE WORD "PROVIDE" IS USED, THIS SHALL MEAN "FURNISH AND INSTALL". 11. COMPLY WITH SAFETY REGULATIONS INCLUDING BUT NOT LIMITED TO OSHA, NFPA-70E AND ALL ELECTRICAL SAFETY REGULATIONS. 12. PROVIDE GROUNDING AND BONDING OF ALL METALLIC RACEWAY, BOXES, WIREWAY, DEVICES AND EQUIPMENT IN ACCORDANCE WITH THE NEC. PROVIDE GROUNDING CONDUCTOR IN ALL POWER CONDUITS. 13, INSTALL ALL DEVICES AND EQUIPMENT IN ACCORDANCE TO THE MANUFACTURER'S RECOMMENDATIONS AND U.L. REQUIREMIENTS. 14. WHERE THE SIZE OF A JUNCTION BOX. PULL BOX OR WIREWAY IS NOT INDICATED ON THE DRAWINGS, THE SIZE SHALL BE SELECTED IN ACCORDANCE WITH THE NEC. WHERE THE ENCLOSURE TYPE OF THE JUNCTION BOX, PULL BOX OR WIREWAY IS NOT INDICATED ON THE DRAWINGS, THE ENCLOSURE TYPE SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS BEING INSTALLED IN ACCORDANCE THE NEC. 15. VOLTAGE DROP FOR FEEDERS AND BRANCH CIRCUITS HAVE BEEN INCLUDED IN THE DESIGN OF THE ELECTRICAL SYSTEM TO MEET A MAXIMUM OF 5% VOLTAGE DROP PERMITTED BY 2017 FBC ENERGY CONSERVATION CODE C405.6.3. 16. PROVIDE LABELS FOR ALL PANELBOARDS, CABINETS AND SAFETY SWITCHES. LABELS SHALL BE MACHINE ENGRAVED, LAMINATED PLASTIC, PERMANENTLY ATTACHED WITH SELF -TAPPING SCREWS OR RIVETS. 17. PROVIDE TYPE WRITTEN PANELBOARD DIRECTORY CARD IN EACH PANELBOARD WITH CIRCUIT LOAD INFORMATION AND ROOM NUMBER -LOAD DESCRIPTION CLEARLY IDENTIFIED.. 18. LABEL ALL JUNCTION BOXES WITH PERMANENT MARKER IDENTIFYING PANEL'S NAME AND CIRCUIT NUMBERS WITHIN. 19. UNDERGROUND CONDUIT WHICH EXTENDS OUTSIDE OF THE STRUCTURE SHALL BE MINIMUM 24" BELOW GRADE. CONDUIT WITHIN THE PERIMETER OF THE STRUCTURE SHALL BE MINIMUM 6" BELOW SLAB U.N.O. RACEWAYS SHALL NOT BE ROUTED IN SLAB ON GRADE. SCOPE OF WORK THE SCOPE OF WORK OF THIS PROJECT IS LIMITED TO PROVIDING A NEW 100A, 120/24OV, 1 PH SERVICE TO POWER THE SITE'S MONUMENT SIGN. eOVERALL SITE PLAN SCALE: NTS OF AREA Ln J O J O = O = 0 Oar-, woNO � o U. U. c~n o�� LLT'Uz N � D w N �, � J � W o � ~ Ln Q 0 �CL J 0 U ISSUED DATE: 06-29-2023 REVISION 1: REVISION 2: REVISION 3: REVISION 4: Eml BUILDING I I I BUILDING I LOT LINE w m oW z {— _J I w ~0 18.37 I � I LU Q 17,90' 0.50' I W J 1 O J I f — < I � Q 1 }O I g 1 22.38' i DIMENSIONS TO OUTSIDE OF PLAYGROUND MULCH BARRIER 60.00' m.y,�vrvrt i BUILDING 6b-1S8-81L >1030 V '1NIOd 83dSNV81 3NVnoS Ld-006-9LL (1Nnon 1SOd) 133HM ONI8331S 30' LOOK —OUT PANEL ATA STEP 718-875-30; n 718— —9 4 r— W m CO I;U3 4' wo N , CI)W DECK co) (A X 18-502-9 I'rm,.I �o BELL (POST MOUNT) ��CR 718-796—P1 FP Od R� OpF GROOVE 11 SLIDE 718-638-4 Play Area Capacity:25-35 ELEVATED PLAY ACTIVITIES -TOTAL 1PE_ ELEVATED PLAY ACTIVITIES ACCESSIBLE BY TRANSFERFEELEVATEDPLAY ACTIVITIES ACCESSIBLE BY RAMPEOD GROUND LEVEL ACIMTYTYPE GROUND LEVEL ACTIVITY OUAMITY 2 REDD Miracle n, To promote safe and proper equipment use by children, Miracle recommends the installation of either a Miracle safety sign or other gropdate safety slgnage near _ each playsystem's main entry polnt(s) to inform parents and supervisors of the age appropriateness of the playsystem and general roles for safe play. THE PLAY COMPONENTS IDENTIFIED IN THIS PLAN ✓ COMPLIES TO CPSC DESIGNED AGES FOR ARE IPEMA CERTIFIED. THE USE AND LAYOUT OF 718-S 186 THESE COMPONENTS CONFORM TO THE 2-12 REQUIREMENTS OF ASTM F1487. ✓ COMPLIES TO ASTM o➢mo mcxou"o E E Acmes®� ➢'EMS NEEDED FOR A➢A COMPIS YCE AN ENERGY ABSORBING PROTECTIVE SURFACE IS ✓ COMPLIES TO ADA TYPE: QUANTITY: REQUIRED UNDER & AROUND ALL PLAY SYSTEMS. PLAYGROUND - SPORTS COURT LAYOUT 2 HS1 1"=20' HS1 PLAYGROUND SPECIFICATION N.T.S. I HARDSCAPE MATERIALS SCHEDULE MAIL KIOSK (4) 16 ADDRESS CLUSTER BOX UNITS) - USPS APPROVED MAILBOXES ON PEDESTALS /\ SALSBURY INDUSTRIES # 3316 OR FLORANCE CORPORATION 1570-16AF OR EQUAL. SURFACE 4 j Q ] MOUNT ON 6' THICK CONC. SLAB WITH CONCRETE ANCHORS. ALLOW 6" BETWEEN CLUSTER BOXES. \-/ COLOR: BLACK ALL PROPOSED EQUIPMENT AND LOCATION FOR EQUIPMENT MUST BE APPROVED BY THE LOCAL POST MASTER PRIOR TO ORDERING EQUIPMENT. BENCH - E FORMS 35 OI BACKED MOUNT 2 Q COLOR: 'BLUE SHP ( OW SHEEN) NO ARMS OR DIVIDERS www.landscapeforms.com pe orms com(800) 521-2546 i EI'EJ 1 Q PETWAS I E DISPOSAL STATION - CROWN PRODUCTS "IMPERIAL" PET WASTE STATION WITH I 10 GALLON RECEPTACLE. www.crownproductsonline.com RASH RECEPTACLE - LANDSCAPE FORMS 35 COLLECTION "PITCH" TRASH RECEPTACLE - SIDE I 2 QT OPENING - SURFACE MOUNT - 28 GALLON CAPACITY - COLOR: "BLUE ASH" (LOW SHEEN) YA-im.landscapeforms.com (800) 521-2546 BIKE RACK - LANDSCAPE FORMS 35 COLLECTION "LOOP" BIKE RACK - EMBEDDED IN CONCRETE - I 1 E COLOR. 'BLUE ASH' (LOW SHEEN) www.landscapeforms.com (800) 521-2546 TABLE • LANDSCAPE FORMS 35 COLLECTION "MINGLE" TABLE - SURFACE MOUNT - THREE BACKED 1 Q SEATS - STEELHEAD SOLID TABLETOP - COLOR: "BLUE ASH" (LOW SHEEN) www.landscapeforms.com (BOO) 521-2546 PLAYGROUND EQUIPMENT - MIRACLE RECREATION, INC. www.miracle-recreation.com 1 Q DISTRIBUTED BY MILLER RECREATION EQUIPMENT & DESIGN - (941) 792-4580 - TOTS CHOICE MODEL 718-S186 OR EQUAL. EQUIPMENT SHALL CONFORM TO ASTM F1 48721 1,690 PLAYGROUND MULCH - POURED -IN -PLACE PLAYGROUND SURFACING SQ, FT. H PLAYGROUND SURFACING SHALL CONFORM TO ASTM F2223-19a & ASTM 51292-18 COMMERCIAL GRADE ALUMINUM PICKET FENCE - 6' HT. AT PERIMETER OF STORMWATER POND / 575 Q 4' HT.AT PLAYGROUND AND SPORTSCOURT (OTHER THAN ADJACENT TO POND). (2) 4 FT. WIDTH L.F. i GATES WITH CHILD LATCH ASPHALTPAVING WITH SPORTS COURT FINISH - MINIMUM 4" DEEP COMPACTED LIMEROCK BASE 2,350 (MAX. #E7 STONE) MINIMUM 1 1/2" HOT MIX ASPHALT LIFT WITH MAXIMUM 1/2" AGGREGATE - SQ. FT. Q 0 COMPACT WITH VIBRATORY ROLLER AND ENSURE NO PUDDLING OF WATER ON COURT (1-2/0 SLOPETO EAST) - PROVIDE ACRYLIC PAINTED SURFACE WITH BASKETBALL COURT STRIPES BASKETBALL GOAL - 42" x 60" ALUMINUM BACKBOARD/RIM/NYLON NET MOUNTED ON 1 Q GOOSENECK STEEL POLE 1,287 287 POUREDIN PLACE CONCRETE SIDEWALK - 4" DEPTH 2500 PSI CONCRETE - 3/8" EXPANSION Q JOINTS FT ALL COLD JOINTS AND VERTICAL OBJECTS - SAW CUT CONTROL JOINTS AS SHOWN ON PLAN. 64 POUREDIN PLACE CONCRETE SIDEWALK - 6" DEPTH 2500 PSI CONCRETE - 3/8" EXPANSION SQ. FT. M JOINTS AT ALL COLD JOINTS AND VERTICAL OBJECTS -SAW CUT CONTROL JOINTS AT 4' O.C. SIGN LIGHTS- KIM LIGHTING NARROW VERTICAL FLOODLIGHT BRONZE FINISH 2 Q MODEL#KFL1-8L-20-4K7-N-UNV-K-DBT-JBR30, CONTROL FOR PHOTOCELL (ON) AND TIMER (OFF), PROVIDE ELECTRICAL CONNECTION AND ELECTRICAL ENGINEERING DESIGN FOR PERMITTING SCALE: ill _ 301 O 15' 30' 60' REVIEW DATE: • ? .2 3 CITY OF ZEPHYRHILLS BUILDING OFFICIAL 7 " oA� W C C 2r�,� H. Ro �✓i/ N N.-) 42712 , S T ®, i z 011-1119,113D, M - NORTH 120 - J 0 o C2 M W J C A Z L O M 00 N a `� i V N 0 V Q M Q Z �� d 8 Cn d A »j rn o N J CD 'a N Ch � M 0 N .•. ti N ti V) 1-11 r, r r� O I 0 w �w� O N � O I.�. �- to O z N u zi O t I-- U < I r, w U p�Q �:]ae 0Z:) U REVISIONS: 1. 1 1/9/22 STRUCTURAL DETAIL REVISED 2. 3• Knot t' below. all More you dig. F4- )ACOB ZIMMERMAN, RIA REG. NO. FL IA 0001653 LANDSCAP RCHITECT c Lt,N� 0 iPi' VI LA0001653 cr , STATE �0 IDo DRAWN BY: 1AZ DATE: -10/1! 2/2 2 22020 HARDS CAPE LAYOU PLAN NSA z N N 0 N t'sr 0 U 30" x 63 3/8" x 2 1/2" THICK PRECAST CONCRETE SILL COLOR: "TAN" FINISH G NSERT ATTACHED TO i" x 8" x 16" SOLID BLOCK DW 8" x 8" x 16" CMU BETWEEN <S - SEE WALL SECTION "B" I POURED CONCRETE FOOTING 1'-6" X 1'-0" 2 1/2" THICK PRECAST CONCRETE WALL CAP COLOR: "TAN" BACKGROUND FIELD ROUTED TO 1 1/4" THICKNESS �= i4= = - fi - 1 - - �•` _ - - (� COLOR: SW7000 "IBIS WHITE" 38 3/8" x 84" x 2" THICK HDPE SIGN FOAM LEAF BACKGROUND FIELD ATTACH TO CMU - I _-� - I - ROUTED TO 1 3/4" THICKNESS WITH EPDXY ADHESIVE - - - COLOR: SW 6709 "GLEEFUL" _ _ LEAF OUTLINE AND LETTERS DOUBLE FACED SIGN PANEL �`____ _ -_.., AT SURFACE OF SIGN FOAM 39 SQ. FT. EACH SIDE _ xt - r -1 (FULL 2" THICKNESS) ->� - COLOR: SW6991 "BLACKMAGIC" LETTERING BACKGROUND FIELD ROUTED TO 1 1/2" THICKNESS t- COLOR: SW6416 "SASSY GREEN" FAUX STACKED STONE VENEER _- - t - CULTURED STONE�'�: " COUNTRY LEDGESTONE �' _ A COLOR:'SKYLINE' -� < I - t 4' x 63 3/8" x 2 112" THICK PRECAST CONCRETE SILL - EACH SIDE - COLOR: "TAN' L_ FINISH GRADE MATERIALS AND FINISHES DIMENSIONS ASSUME 1 3/4" STONE VENEER WIDTH DIMENSIONED ELEVATION 1 ENTRANCE SIGN H!!2.,) 1/2" = V-0" : 1 1/2" OVERHANG DN ALL SIDES 1'SLOPE TOWARD EACH SIDE OF SIGN WALL FROM MIDPOINT -\ 2'-68" - PRECAST CONCRETE COLUMN CAP EPDXY TO TOP OF CMU COLUMN KNOCK -OUT BLOCKS ON TOP COURSE OF COLUMN- WITH �- #5 REBAR BENTS- FILL ALL CELLS WITH CONCRETE '`- (3) #5 REBAR CONTINUOUS #5 VERTICAL REBAR @ 8" O.C. NOTES: 1. FILL ALL BLOCK BELOW GRADE WITH CONCRETE. 2. PROVIDE #1 GAUGE HORIZONTAL REINFORCING GRID AT 24" O.C. VERTICALLY PRECAST CONCRETE SILL SIGN FOAM INSERT (EACH SIDE) WALL REINFORCED WITH #5 REBAR BENTS- FILL ALL CELLS WITH CONCRETE ALTERNATE CMU DIRECTION EVERY OTHER COURSE SAFETY PROTECTION ON VERTICAL REBAR UNTIL BLOCK WORK BEGINS PROVIDE #1 GUAGE HORIZONTAL RENINFORCING AT 24" O.C. VERTICALLY (EVERY THIRD COURSE) (4) #5 REBAR DOWELS- 25" OVERLAP ON ALL SPLICES i TIE ALL REBAR CONNECTIONS WITH METAL TIES FINISH GRADE TIE ALL REBAR CONNECTIONS WITH METAL TIES ®I -; i I I f.l ADJUST COVER OVER FOOTING TO �- MINIMIZE CUT BLOCK COURSES f;i ,il ti (4) #5 HORIZONTAL REBAR CONTINUOUS, ° •. d HOLD REBAR 3" OFF BOTTOM AND EDGE OF POUR J.A. a a d #5 TRANSVERSE REBAR AT 24" O.C.- HOLD ;�.' ° • • I I , 3" OFF BOTTOM AND EDGE OF POUR 3000 PSI POURED CONCRETE 4-6 FOOTING -CONTINUOUS COMPACT SUBGRADE AT ALL SECTION "D" FOOTING LOCATIONS PROVIDE #1 GUAGE HORIZONTAL RENINFORCING AT 24" O.C. VERTICALLY (EVERY THIRD COURSE) #5 VERTICAL REBAR SIGN WALL MAX. 24" O.C. VENEER WALL TIES STONE VENEER STONE VENEER 111 l l • ' . L ! • . E D #5 VERTICAL REBAR AT ALL CORNERS Lj�q VENEER WALL TIES FILL ALL CELLS WITH CONCRETE SECTION "C" PROVIDE #1 GUAGE HORIZONTAL RENINFORCING AT 24" O.C. ELEVEN COURSES VERTICALLY (EVERY THIRD COURSE) 6" x 8" x 16" SOLID BLOCK STONE VENEER SIGN WALL VENEER WALL TIES STONE VENEER :•• #5 VERTICAL REBAR a aE �E �E El El�� AT ALL CORNERS a.. :-1 a ZI .VENEER WALL TIES FILL ALL CELLS WITH CONCRETE SECTION "B„ 125.00'(P) - - - - - - - - - - - - - - - 1 --------------------------------, I I I ( I t � i t t I I I I I I I 1 I I I I t 1 I I I I I I I i I I I t _77- N --------------- 20' SIGN OFFSET FROM INTERSECTION OF 1 RIGHTS -OF -WAY 1 HS2 Zco A LQ Q_ ®. ------ ----, ,---- (---- ----, o J "� E�Z O �com Q: Q� - ---I I--- --' --- '--- I (z) p�u ��3� N W I I I I j I I t --------------- ! I ! _= N - RACT 19 1 i t ! GROUP LLC 6-21-0030-01900-0010 7431, PG. 1814 1, PG. 55 ! OR 4.72.f ACRES ! & 1 t i 1 44.00'(P) C 59.00'(P)rl -F 1 AINAG 10 DR i STORY 1 STORY ENTRANCE SIGN LAYOUT PLAN SCALE. 1 - 30 r+ 0 0 U a Q W E 0 v o �t ti y z M J � U. A O Q 9 3 00 fc N a d t J a v N E z m U N d A N � J 5 N Ch oc tn N n N O !_ o o pL o >` p Wo C2 �w O N Q o i.L ram■ O 0 O I r I.�.. N U n� S w cI 1-- V Y wj U "Mi � �../^ 0. 0 U SIGN WALL #5 VERTICAL REBAR MAX. 24" O.C. VENEER WALL TIES STONE VENEER STONE VENEER EGI-Engineering Great Ideas, Inc. � D a EEI .ti. 1f] El D #5 VERTICAL REBAR 1003 S. Alexander Street AT ALL CORNERS Suite # 5 0 EE l IE Plant City, Ff. 33563 VENEER WALL TIES .• a•E ... <• <:. w FILL ALL CELLS WITH WILLIAM L I A M N R C E T S E N° �S Z% PROVIDE #1 GUAGE HORIZONTAL SECTION "A" RENINFORCING AT 24" O.C. P R I V A T E P R 0 V 10 E R \\ H' VERTICALLY (EVERY THIRD COURSE) P N (EDG' E �� GC IsC1A3 Nf 5 ? 7 Q7 B \`\-� CEAt e-mail, RROBERT;.EGI@GMAIL,com . top -- N� 42712 °` #5 VERTICAL REINFORCEMENT BARS (TYPICAL) (MAXIMUM 24" O.C. ° F CMU BLOCKS FOR SIGN WALL #5 VERTICAL REINFORCEMENT BARS ✓ 4� (TYPICAL) (MAXIMUM 8" O.C. 'U E! i�BJ a 4. ° a a •.d ! .•. ,t • .. r f 1 I I 1 A REVISIONS: �`' 1. 11/9/22 DIE E . DIE D ❑ • ... E � � NOTES: 1. WILLIA G. REIDY I IGNING AND SEALI G FOR STRUCTURAL DETAIL 3' o° ° .�� [�. O . ° .. e STRUCTU NEERING ONLY REVISED �a' a I � a11�1 MMEIEF O 2. DESIGN MEETS 2020 FLORIDA BUILDING CODE, d 'O • '•° d.,. 7th EDITION & ASCE DESIGN WIND SPEE : 145 3 1 V-6" -1 WIND PRESSURE: 38. REVIEW DATE:-_.." L- SIGN FOOTING CITY OF ZEPHYRHIL.L.S BUILDING OFFICIAL_-- 4- DRAWN BY: IAZ WILLIAM G. REIDY, P.E. DATE: /22 REG. NO. 35605 PROFESSIONAL ENGINEER 22020 ENTRANCE SIGN 2� DETAILS �I 2 MASONRY BUILDING BUILDING LOT j Lu LINE I m I w I w ~O I Z o I Q 17.90' I a- -i 0. r LL J I O I � � o< I I g 22.E I I I BUILDING I I DIMENSIONS TO OUTSIDE OF _,/� PLAYGROUND MULCH BARRIER 60,00' 0 0 1 HS1 PLAYGROUND - SPORTS COURT LAYOUT 1"=20' w W I I BUILDING I I Play Area Capacity: 25-35 I 1 STORY MASONRY BUILDING 617-1,98-8LL v A030 J, 'iNIOd b33SN a 3a'dn0S Ld-006-2 LL (1NnOW isOd) 133HM 0NN33iS 30' LOOK -OUT PANEL 718-875-30 ATA STEP �m 718- 1 -9 m I00� 4- C°o Nam W DECK 18-502-9 onU 6� n om rBELL v� �Fh (POST MOUNT) 718-796-P1 pa�CRsp�'F .96,ppF c pp� -R� GROOVE It SLIDE 718-638-4 I I BUILDING ELEVATED PLAY ACTIVITIES -TOTAL ELEVATED PLAY ACTMDES ACCESSIBLE BY TRANSFER REO'D ELEVATED PLAY ACTIVITIES ACCESSIBLE BY RAMP 1 REO'D GROUND LEVEL ACTRM TYPE 2 9EO'D GROUND LEVEL ACTIVITY WARM ,Z FEW Miracle � each playsystern and pro entry pomt(sj to info m parents and supervisors recommends fdthe age apprropriaten ss of therplaysystem annd generalrrulasrfor safsafety play Slgnage near — THE PLAY COMPONENTS IDENTIFIED IN THIS PLAN ✓ COMPLIES TO CPSC DESIGNED FOR ARE IPEMA CERTIFIED. THE USE AND LAYOUT OF 718-S 186 AGE THESE COMPONENTS CONFORM TO THE ✓ COMPLIES TO ASTM o,w�Ro�2 REQUIREMENTS OF ASTM F1487. ii'Et5 NEFDE" FOR ADR COMaLiA\� AN ENERGY ABSORBING PROTECTIVE SURFACE IS ✓ COMPLIES TO ADA TYPE: QUANTITY: REQUIRED UNDER & AROUND ALL PLAY SYSTEMS. 2 HS1 PLAYGROUND SPECIFICATION N.T.S. HARDSCAPE MATERIALS SCHEDULE MAIL KIOSK (4) 16 ADDRESS CLUSTER BOX UNITS) - USPS APPROVED MAILBOXES ON PEDESTALS SALSBURY INDUSTRIES # 3316 OR FLORANCE CORPORATION 1570-16AF OR EQUAL. SURFACE 4 Q MOUNT ON 6" THICK CONC. SLAB WITH CONCRETE ANCHORS. ALLOW 6" BETWEEN CLUSTER BOXES COLOR: BLACK ALL PROPOSED EQUIPMENT AND LOCATION FOR EQUIPMENT MUST BE APPROVED BY THE LOCAL POST MASTER PRIOR TO ORDERING EQUIPMENT. 2 Q BENCH - LANDSCAPE FORMS 35 COLLECTION "STAY" BACKED BENCH - SURFACE MOUNT - COLOR: "BLUE ASH" (LOW SHEEN) - NO ARMS OR DIVIDERS www.landscapeforms.com (800) 521-2546 1 Q PET WASTE DISPOSAL STATION - CROWN PRODUCTS "IMPERIAL" PET WASTE STATION WITH 10 GALLON RECEPTACLE. www.crownproductsonline.com \ TRASH RECEPTACLE - LANDSCAPE FORMS 35 COLLECTION "PITCH" TRASH RECEPTACLE - IDE 2 Q OPENING - SURFACE MOUNT - 28 GALLON CAPACITY - COLOR: "BLUE ASH" (LOW SHEEN) www.lardscapeforms.com (800) 521 2546 1 Q BIKE RACK - LANDSCAPE FORMS 35 COLLECTION "LOOP" BIKE RACK - EMBEDDED IN CONCRETE - "BLUE COLOR: ASH" (LOW SHEEN) www.landscapeforms.com (800) 521-2546 TABLE - LANDSCAPE FORMS 35 COLLECTION "MINGLE" TABLE - SURFACE MOUNT - THREE BACKED 1 F SEATS - STEELHEAD SOLID TABLETOP - COLOR: "BLUE ASH" (LOW SHEEN) www.landscapeforms.com (800) 521-2546 PLAYGROUND EQUIPMENT -MIRACLE RECREATION, INC. www.miracle-recreation.com 1 G DISTRIBUTED BY MILLER RECREATION EQUIPMENT & DESIGN - (941) 792-4580 - TOTS CHOICE MODEL 718-S186 OR EQUAL. EQUIPMENT SHALL CONFORM TO ASTM F1487-21 1,690 PLAYGROUND MULCH - POURED -IN -PLACE PLAYGROUND SURFACING SQ. FT. H PLAYGROUND SURFACING SHALL CONFORM TO ASTM F2223-19a & ASTM 51292-18 COMMERCIAL GRADE ALUMINUM PICKET FENCE - 6' HT. AT PERIMETER OF STORMWATER POND / 575 Q 4' HT. A7 PLAYGROUND AND SPORTSCOURT (OTHER THAN ADJACENT TO POND). (2) 4 FT. WIDTH L.F. GATES WITH CHILD LATCH ASPHALT PAVING WITH SPORTS COURT FINISH - MINIMUM 4" DEEP COMPACTED LIMEROCK BASE Q STONE) MINIMUMAGGREGATEX ASPHALT LIFT WITH MAXIMUM 1/2 MOI SQ FT. COMPACTWITH VIBRATORY NO PUDDLING OF WATER ON OURT(12% C SLOPE TO EAST) - PROVIDE ACRYLIC PAINTED SURFACE WITH BASKETBALL COURT STRIPES 1 Q BASKETBALL GOAL - 42" x 60" ALUMINUM BACKBOARD/RIM/NYLON NET MOUNTED ON GOOSENECK STEEL POLE 1,287 POURED IN PLACE CONCRETE SIDEWALK - 4" DEPTH 2500 PSI CONCRETE - 3/8" EXPANSION SQ. FT. Q JOINTS AT ALL COLD JOINTS AND VERTICAL OBJECTS - SAW CUT CONTROL JOINTS AS SHOWN ON PLAN. 64 POURED IN PLACE CONCRETE SIDEWALK - 6" DEPTH 2500 PSI CONCRETE - 3/8" EXPANSION SQ. FT. M Q JOINTS AT ALL COLD JOINTS AND VERTICAL OBJECTS - SAW CUT CONTROL JOINTS AT 4' O.C. SIGN LIGHTS- KIM LIGHTING NARROW VERTICAL FLOODLIGHT BRONZE FINISH 2 Q MODEL#KFL1-8L-20-4K7-N-UNV-K-DBT-JBR30, CONTROL FOR PHOTOCELL (ON) AND TIMER (OFF), PROVIDE ELECTRICAL CONNECTION AND ELECTRICAL ENGINEERING DESIGN FOR PERMITTING SCALE: III _ 301 0 151 301 EGI-Engineering Great Ideas, Inc. 1003 S. Alexander Street Suite # 5 Plant City, F1.33563 WILLIAM, H R00ERTS PE N9 42712 PRIVATE PR0V10ER EGI, INC CA NP 29098 PH011E NO 813-752-7076 e-ma-il, RR00ERTS.EGIMAIL.com NORTH 60' 120 57 A O O Q w E 0 o� Z M� J C U. z O M Q O 0 C M N N � J a c> Q 0 N a2i A -0 CO J s NM o� O M N h CM 0 rJ r o ~ <^ Q r-LW � o O O 1�� N V 0 < N V W I un W WU r- V r...� V) p 0. M 0 a V H. \EENS REVISIONS: Nn 42712 1. 1 1 /9/2 2 - * = STRUCTURAL DETAIL s F REVISED 2. 2. e 0 iI! 7/ Kno t' below. a�e ore you dig. 4- )ACOB ZIMMERMAN, RLA REG. NO. FL LA 0001653 LANDSCAP ARCHITECT ��(,DS CAA 9 � �gEW 2 y r STATE y OF " 0R I'D DRAWN BY: JAZ DATE: 10/12/22 22020 HARDS CAPE LAYOU PLAN HST U t a 4 N N 0 N s 0 U 30" x 63 3/8" x 2 1/2" THICK PRECAST CONCRETE SILL COLOR: "TAN" FINISH C FIN 2 1/2" THICK PRECAST CONCRETE WALL CAP COLOR: "TAN" MATERIALS AND FINISHES DIMENSIONS ASSUME 1 3/4" STONE VENEER WIDTH — 9'-108° DIMENSIONED ELEVATION 1 ENTRANCE SIGN HS2 1 1/2" = V-0" VSERT ATTACHED TO �' x 8" x 16" SOLID BLOCK )W 8" x 8" x 16" CMU BETWEEN <S - SEE WALL SECTION "B" I POURED CONCRETE FOOTING 1'-6" X V-0" 1 ° SLOPE TOWARD EACH SIDE OF SIGN WALL FROM MIDPOINT 2'_6,8 PRECAST CONCRETE SILL WALL REINFORCED WITH #5 REBAR BENTS - FILL ALL CELLS WITH CONCRETE PROVIDE #1 GUAGE HORIZONTAL RENINFORCING AT 24" O.C. VERTICALLY (EVERY THIRD COURSE) TIE ALL REBAR CONNECTIONS � WITH METAL TIES L_- dA < °e d e° 4'-6" SECTION "D" PRECAST CONCRETE COLUMN CAP EPDXY TO TOP OF CMU COLUMN KNOCK -OUT BLOCKS ON TOP COURSE OF COLUMN- WITH #5 REBAR BENTS- FILL ALL CELLS WITH CONCRETE (3) #5 REBAR CONTINUOUS #5 VERTICAL REBAR @ 8" O.C. NOTES: 1. FILL ALL BLOCK BELOW GRADE WITH CONCRETE. 2. PROVIDE #1 GAUGE HORIZONTAL REINFORCING GRID AT 24" O.C. VERTICALLY SIGN FOAM INSERT (EACH SIDE) ALTERNATE CMU DIRECTION EVERY OTHER COURSE SAFETY PROTECTION ON VERTICAL REBAR UNTIL BLOCK WORK BEGINS - (4) #5 REBAR DOWELS- 25" OVERLAP ON ALL SPLICES TIE ALL REBAR CONNECTIONS WITH METAL TIES FINISH GRADE ADJUST COVER OVER FOOTING TO ^t! MINIMIZE CUT BLOCK COURSES (4) #5 HORIZONTAL REBAR CONTINUOUS, HOLD REBAR 3" OFF BOTTOM AND EDGE OF POUR #5 TRANSVERSE REBAR AT 24" O.C.- HOLD 3" OFF BOTTOM AND EDGE OF POUR �� 3000 PSI POURED CONCRETE FOOTING- CONTINUOUS COMPACT SUBGRADE AT ALL FOOTING LOCATIONS PROVIDE #1 GUAGE HORIZONTAL RENINFORCING AT 24" O.C. BACKGROUND FIELD VERTICALLY (EVERY THIRD COURSE) -ROUTED TO 1 1/4" THICKNESS #5 VERTICAL REBAR COLOR: SW7000 "IBIS WHITE" MAX. 24" O.C. SIGN WALL VENEER WALL TIES LEAF BACKGROUND FIELD STONE VENEER TONE VENEER ROUTED TO 1 3/4" THICKNESS COLOR: SW 6709 "GLEEFUL" DE D � . ' a . ' , � , ' El . �' VERTICAL REBAR LEAF OUTLINE AND LETTERS a IREI+ IE + 1[01�]E] a ALL CORNERS + + e� rAT AT SURFACE OF SIGN FOAM (FULL 2" THICKNESS) COLOR: SW6991 "BLACKMAGIC" l � ° ' l �L=E] NEER WALL TIES D FILL ALL CELLS WITH CONCRETE SECTION "C" LETTERING BACKGROUND FIELD -ROUTED TO 1 1/2" THICKNESS PROVIDE #1 GUAGE HORIZONTAL COLOR: SW6416 "SASSY GREEN" RENINFORCING AT 24" O.C. ELEVEN COURSES VERTICALLY (EVERY THIRD COURSE) 6" x 8" x 16" SOLID BLOCK VENEER WALL TIES 1 1/2" OVERHANG DN ALL SIDES •l • E fig ► �I �fi� �' � SECTION "B" SIGN WALL SECTION "A" #5 VERTICAL REBAR MAX. 24" O.C. iPON AIROVIDE #1 GUAGE•. • OR VERTICALLY (EVERY R.COURSE) #5 VERTICAL REINFORCEMENT BARS (TYPICAL) (MAXIMUM 24" O.C. :CMU BLOCKS FOR SIGN WALL #5 VERTICAL REINFORCEMENT BARS r_ (TYPICAL) (MAXIMUM 8" O.C. e .. vi 3'-0" 4e Qa s sol�so �'s■ Q0 00� aQ v e, � d e — _ ° a ee. .. b - 4. .. .e e, r e e ° d 1 V-6" -= SIGN FOOTING REVIEW EW MATE: < 2 t •�-3 CITY OF ZEPHYRHILLS BUILDING OFFICIAL OFFSET FROM INTERSECTIONOF N TRACT 19 ' GROUP LLC '6-21-0030-01900-0010 7431, PG. 1814 1. 1, PG. 55 t OR 4.72f ACRES 44.00'(P) E:j 59.00'(P) ❑ j1 STORY 1 STORY 10' DRAINA ENTRANCE SIGN LAYOUT PLAN SCALE: 1" = 30' roi ON ti W� UjCL co�ti`to Z oc'Km �p W J V to W N� WILLIAI4 91 RP,OERTS PE IIq 42712 PRIVA`iE PROVIDER EGi, INC CA IIh 29090 PHONE H0 813-752-707B e-Ot, RR0BERTS.EGI@GMAIL,com �\\\\IIIIII///// EGI-Engineering Great Ideas, III. 1003 S. Alexander Street Suite # 5 Plant City, Fl. 33563 NN .tom �. N? 42712 STAT F CU ZZ NOTES: 1. WILLIAM G. REIDY IS SIGNING AND SEALING FOR STRUCTURAL ENGINEERING ONLY 2. DESIGN MEETS 202OELORIDA BUILDING CODE, 7th EDITION & ASC -16. DESIGN WIND SPE D: 145 MP WIND PRESSURE: PSF WILLIAM G. REIDY, P.E. REG. NO. 35605 PROFESSIONAL ENGINEER v� I� E 0 O �G Z M J LL z E)o� Q 3 00 O O N oe d t J P a U (n ,Q E M QZ W N N d 'a O S NM O M 0 N .. n N n r r� O � 1 <^ Q r� w n� o v1 O r N U 0 U w �w0 U Q pL �- tJ U REVISIONS: 1. 11/9/22 STRUCTURAL DETAIL REVISED 04 a In DRAWN BY: IAZ DATE: 10/1 2/22 22020 ENTRANCE SIGN DETAILS fiS2