HomeMy WebLinkAbout23-60555335 Eighth Street Zephyrhills, FL 33542 Phone: (813) 780-0020 Fax: (813) 780-0021 B 3 1_ Issue Date: 07/20/2023 Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. 0111 . . ............... SIGNATURE I — — -- — - SC 1-1/2" CONDUIT W/ PULL STRING SC VERIFY MH: 18 MH: 18 TRANSFORMER I LOCATION PRIOR HH HH TOINSTALLTI N I: i II II • i j� it ii ii a I I I oa. a O a a Id a G O �_ l o, _ 10 SA MH:�HH 1-1/2" CONDUIT W/ PULL STRING 1 Cr CT 200A 200A 400A CAN METER DISC. DISC. DISC. MH: 12 1" CONDUIT W/ PULL STRING FOR FUTURE SIGN \ "000 SA '- MH: 1 Or!M TWO 2" CONDUIT W/ PULL STRING FOR PHONE AND CABLE TO SERVICE POINT TO BE DETERMINED IN FIELD. SW MH: 12 SCOPE OF WORT: PROVIDE NEW 800AMP SERVICE TO NEW SHELL BUILDING. PROVIDE CT CAN AND METER i ' PROVIDE NEW DISCONNECTS, AS SHOWN ON RISER. ' PROVIDE TWO 4" CONDUITS FROM TRANSFORMER LOCATION �1 TO NEW SERVICE WITH WIRING AS SHOWN ON PLAN. PROVIDE CONDUITS AND HANDHOLES AS SHOWN ON THE � PLAN FOR FUTURE LIGHTING. PROVIDE TWO 2" CONDUITS FOR PHONE AND CABLE FROM SERVICE POINT TO NW CORNER OF BUILDING PER PLAN. � ELECTRICAL PLAN SCALE: 1 /8" = 1'-0" 2 SETS OF 4#600MCM CU IN 4" CONDUIT EACH SET VERIFY TRANSFORMER LOCATION r PRIOR TO INSTALLATION � I SB MH: 18 C 0 O 0 ° a O 0 O 0 �., 00 I SB MH: 18 4 916 TAT OF W- JUN 1 6 2023 ues"IgnTed n ernattona, il Associates, Inc. AA26001933 Architecture e Planning - Interior Design 14125 N.W. 80th Ave. Suite 303 Miami Lakes, FI. 33016 T. 786-235-9097 F. 305-362-4420 dtiinfo@dtiarchitect.com www.dtiarchitect.com Carlos Pizarro, R.A. AR - 0013079 Revisions: 1. REVISION 06-14-23 Z0 M Q LG. LIJ _v0 w� - H 0 W F' Z cn U. a �_ 0 W ZV Q2 <� w = (L - W m o �0 j2 J °a w 0w off Z 0 Q � v� z � 0�' aM. Q EJ 2 LU v M0� QZ0 0 �0-uj. _ > > (L 0.0 coa U W N N W n Job Number: 22008.01 File name: Issued Date: Drawn by: Checked by: SHEET NAME ELECTRICAL PLAN BUCHANAN P.E CONSULTING INC. ELECTRICAL * MECHANICAL * PLUMBING ENGINEERING SHEET NUMBER 6191 W. ATLANTIC BLVD, SUITE# 2 MARGATE, FL 33063 Phi 954-590-3300 Fax, 954-590-2232 EMalli BUCHANAN@MEPENGINEERS,C❑M r CERTIFICATE OF AUTH❑RIZATI❑N # E-1 ❑RAJA BUCHANAN P.E # 48916 GENERAL ELECTRICAL NOTES 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE (N.E.C. 2014), FLORIDA BUILDING CODE 2017 AND GOVERNING MUNICIPAL, STATE AND LOCAL CODES. ALL MATERIAL SHALLBE NEW AND SHALL BEAR THE U.L. LABEL WHERE APPLICABLE. 2. ALL, 'WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR IN A FIRST CLASS WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL BE FULLY OPERATIVE AND ACCEPTED BY THE OWNER. 3. IT IS NOT THE INTENT OF THESE PLANS TO SHOW EVERY MINOR DETAIL OF CONSTRUCTION. THE CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ALL ITEMS FOR A COMPLETE ELECTRICAL SYSTEM AND PROVIDE ALL REQUIREMENTS NECESSARY FOR EQUIPMENT TO BE PLACED IN PROPER WORKING ORDER. 4. CONTRACTOR SHALL MAKE ALL NECESSARY CUTTING AND DO ALL THE REPATCHING AS NECESSARY FOR THE PROPER EXECUTION OF THIS WORK. 5. AFTER COMPLETION OF THE INSTALLATION, THE SYSTEM SHALL TEST FREE FROM SHORT CIRCUITS AND GROUNDS. 6. WHERE ELECTRICAL CONDUCTORS ARE INSTALLED IN CONDUIT, THE CONDUIT SHALL COMPLY WITH THE N.E.C. REQUIREMENTS. 7. ALL CONDUCTORS SHALL BE COPPER. NO CONDUCTOR SHALL BE SMALLER THAN #12 AWG AND SHALL BE RATED FOR 600VOLTS THWN OR THHN INSULATION. INSTALL A GROUNDING CONDUCTOR WITH ALL CIRCUITS, UNLESS NOTED OTHERWISE, SIZED PER N.E.C. 250-122. ,. 8. VERIFY BREAKER AND CORRESPONDING WIRE SIZES FOR ALL ELECTRICAL EQUIPMENT. DO NOT ORDER MATERIAL BEFORE VERIFYING BREAKER & WIRE SIZE. REPORT ANY DISCREPANCY IMMEDIATELY TO THE ENGINEER OF RECORD. 9. ALL OUTDOOR DISCONNECTS AND ELECTRICAL PANELS TO BE NEMA-3R. ALL OUTDOOR DISCONNECTS AND ELECTRICAL PANELS IN A SALT SPRAY AREA TO BE NEMA-4X. 10. PANELS SHALL BE SQUARE 'D', GENERAL ELECTRIC OR EQUAL, TYPE AND NUMBER OF BREAKERS AS INDICATED ON PANEL SCHEDULE. STENCIL PANEL DESIGNATION ON INSIDE OF PANEL. ALL TWO -POLE BREAKERS SHALL BE COMMON TRIP. PROVIDE TYPE WRITTEN SCHEDULE IN EACH LOAD CENTERS. CONNECTION TO MAIN BUS SHALL BE WITH BURNDY ANNULAR COMPRESSION LUGS. PANELS AIC RATING SHALL BE AS INDICATED ON PLANS. 11. PROVIDE NAMEPLATES FOR ALL PANEL BOARDS, DISCONNECTS, TRANSFORMER, TERMINAL CABINETS AND ALL ELECTRICAL EQUIPMENT IDENTIFIED BY NAME ON DRAWINGS. 12: ALL ELECTRICAL MATERIALS, DEVICES, APPLIANCES AND EQUIPMENT SHALL BE LABEL LISTED BY AN APPROVED THIRD PARTY TESTING AGENCY. 13. LOAD DATA IS BASED ON INFORMATION GIVEN ENGINEER AT TIME OF DESIGN. VERIFY ALL EQUIPMENT AND PANEL SIZES BEFORE ORDERING AND BEFORE INSTALLATION. 14. ALL EXTERIOR ELECTRICAL EQUIPMENT SHALL BE ANCHORED TO COMPLY WITH LOCAL CODE FOR WIND RESISTANCE. 15. ALL ELECTRICAL AND COMMUNICATIONS OUTLETS TO BE AT 15" A.F.F TO BOTTOM OF OUTLET UNLESS OTHERWISE NOTED, ALL LIGHT SWITCHES SHALL BE ® 48" AFF. TO TOP OF SWITCH. 16. TIME CLOCK FOR LIGHTING CONTROL TO BE AN ASTRONOMICAL TIME CLOCK. 17. THE CONTRACTOR SHALL CONTACT THE LOCAL POWER COMPANY AND OBTAIN, IN WRITING, THE AVAILABLE FAULT CURRENT OF THE UTILITY TRANSFORMER. THE CONTRACTOR SHALL ENSURE THAT ALL ELECTRICAL EQUIPMENT HAS AN AMP INTERRUPTING CAPACITY (AIC) GREATER THAN THE AVAILABLE FAULT CURRENT AT ANY POINT IN THE ELECTRICAL DISTRIBUTION SYSTEM. 18. WIRING METHOD: ALL CONDUCTORS SHALL BE INSTALLED IN ELECTRICAL METALLIC TUBING (EMT) OR MC CABLE & FLEXIBLE METAL CONDUIT (GREENFIELD) AS PER NEC 330-10, PROVIDED IT IS USED IN NON DESTRUCTIVE OR CORROSIVE SURROUNDINGS AS SPECIFIED IN NEC 2014 330-12. ALL FITTINGS AND COUPLINGS FOR EMT CONDUIT SHALL BE ALL STEEL RAIN TIGHT COMPRESSION TYPE OR ALL STEEL CONCRETE TIGHT SET SCREW TYPE. SCHEDULE 40 PVC CONDUIT, WITH FITTINGS AND COUPLINGS APPROPRIATE FOR THE USE, SHALL BE USED UNDERGROUND OR BELOW SLABS ON GRADE. 19. BRANCH -CIRCUIT WIRING, OTHER THAN 2-WIRE OR MULTIWIRE BRANCH CIRCUITS SUPPLYING POWER TO LUMINAIRES CONNECTED TOGETHER, SHALL NOT BE PASSED THROUGH AN OUTLET BOX THAT IS AN INTEGRAL PART OF A LUMINAIRE UNLESS THE LUMINAIRE IS IDENTIFIED FOR THROUGH -WIRING. LUMINAIRES SHALL NOT BE USED AS A RACEWAY FOR CIRCUIT CONDUCTORS UNLESS LISTED AND MARKED FOR USE AS A RACEWAY. PROVIDE J-BOXES AS REQUIRED. 20. SEAL ALL NEW CONDUIT PENETRATIONS THROUGH FIRE RATED WALLS, CEILINGS, FLOORS, ETC., TO MAINTAIN EXISTING FIRE RATING CONDITIONS, FURNISH AND INSTALL FIRE RATED ENCLOSURES FOR ALL EQUIPMENTS PENETRATING FIRE RATED ENVELOPES, SPACES, ECT. 21. ELECTRICAL CONTRACTOR IS RESPONSIBLE TO PROVIDE WIRING FOR HVAC SYSTEM: A/C EQUIPMENT(S), SMOKE DETECTORS, THERMOSTATS, TEST STATIONS, MOTORIZED VOLUME DAMPERS, ETC. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL DRAWINGS AND PROVIDE ALL NECESSARY CONTROL WIRING. ELECTRICAL CONTRACTOR TO THOROUGHLY REVIEW MECHANICAL PLANS AND PROVIDE POWER TO ANY MECHANICAL EQUIPMENT OR DEVICE THAT IS NOT SHOWN ON ELECTRICAL PLANS BUT IS SHOWN ON MECHANICAL PLANS. 22. INSTALL "GFCI" GROUND FAULT INTERRUPTER RECEPTACLES WITH WEATHERPROOF COVER WITHIN 25 FT OF HVAC EQUIPMENT, MOUNT RECEPTACLE ON UNISTRUT (UNLESS HVAC EQUIPMENT IS SPECIFIED WITH FACTORY INSTALLED CONVENIENT RECEPTACLE) . 23. WHEN NEW ELECTRIC SERVICE IS BEING INSTALLED, IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO COORDINATE WITH FPL/FPL ENGINEERS ON THE SIZE OF THE FPL TRANSFORMER THAT IS REQUIRED TO PROVIDE THE NEW ELECTRIC SERVICE SHOWN ON ELECTRIC PLANS, GC HAS TO INFORM THE OWNER ABOUT ANY EXTRA FPL CHARGES THAT MIGHT OCCUR IN ORDER TO PULL NEW SERVICE. THIS HAS TO BE DONE AS EARLY AS POSSIBLE DURING THE BIDDING PROCESS. 24. ELECTRICAL SERVICE EQUIPMENT MUST BE 3' ABOVE MSL, AND 8' ABOVE N.V.G.D. VERIFY AT SITE. ALL ELECTRICAL EQUIPMENTS SHALL BE INSTALLED ABOVE FLOOD LEVEL. 25. CONTRACTOR MUST VISIT THE SITE PRIOR TO BID OR CONSTRUCTION TO VERIFY ALL EXISTING CONDITIONS. BEFORE SUBMITTING BID, BECOME THOROUGHLY FAMILIAR WITH ACTUAL EXISTING CONDITIONS AT THE BUILDING SITE. THE INTENT OF THE WORK IS SHOWN ON THE DRAWINGS AND DESCRIBED HEREINAFTER. BY THE ACT OF SUBMITTING A BID PROPOSAL FOR WORK, THE CONTRACTOR SHALL BE DEEMED TO HAVE MADE SUCH STUDY AND EXAMINATION AND TO ACCEPT ALL CONDITIONS PRESENT AT THE SITE. NO REQUEST FOR ADDITIONAL PAYMENT SHALL BE CONSIDERED AS VALID, DUE TO THE FAILURE TO ALLOW FOR CONDITIONS WHICH MAY EXIST. CONTRACTOR TO REPLACE ANY EXISTING DEVICE OR COMPONENT THAT IS CALLED AS EXISTING IF IT IS NOT FULLY OPERATIONAL. 26. WIRING METHODS IN ALL PATIENT CARE AREAS TO BE IN COMPLIANCE WITH REDUNDANT GROUNDING REQUIREMENTS OF NEC 2014 SECTION 517.13. 27. ALL DIMMING MECHANISMS HAVE TO BE COMPATIBLE WITH FIXTURE DIMMING REQUIREMENTS. CONTRACTOR MUST VERIFY ALL DIMMING MECHANISM AND FIXTURE DIMMING REQUIREMENTS BEFORE ANY ORDERING, INSTALLING, OR WIRING OF ANY DIMMING MECHANISMS AND FIXTURES. 28. ALL OUTDOOR RECEPTACLES TO BE GFCI & WEATHER PROOF. 29. CONTRACTOR MUST REVIEW THE OWNER WORK LETTERS AND PROTOTYPE DRAWINGS PRIOR TO BID OR CONSTRUCTION TO VERIFY ALL REQUIREMENTS. BEFORE SUBMITTING BID, BECOME THOROUGHLY FAMILIAR WITH THE OWNER WORK LETTERS AND PROTOTYPE DRAWINGS. THE INTENT OF THE WORK IS SHOWN ON THE DRAWINGS AND DESCRIBED HEREINAFTER. BY THE ACT OF SUBMITTING A BID PROPOSAL FOR WORK, THE CONTRACTOR SHALL BE DEEMED TO HAVE MADE SUCH STUDY AND EXAMINATION PROVIDED IN WRITING TO THE ENGINEER/ARCHITECT ANY DISCREPANCIES, NO REQUEST FOR ADDITIONAL PAYMENT SHALL BE CONSIDERED AS VALID DUE TO THE FAILURE TO ALLOW FOR COORDINATION. CONTRACTOR TO PROVIDE THE TENANT WITH ALL REQUIRED ITEMS. PER FLORIDA BUILDING CODE 2017 ENERGY CONSERVATION: 405.6.3 VOLTAGE DROP. 405.6.3 THE CONDUCTORS FOR FEEDERS AND BRANCH CIRCUITS COMBINED SHALL BE SIZED FOR A MAXIMUM OF 5 PERCENT VOLTAGE DROP TOTAL. 405.6.4 COMPLETION REQUIREMENTS. 405.6.4.1 DRAWINGS. CONSTRUCTION DOCUMENTS SHALL REQUIRE THAT WITHIN 30 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER, INCLUDING: 1. A SINGLE -LINE DIAGRAM OF THE BUILDING ELECTRICAL DISTRIBUTION SYSTEM AND 2. FLOOR PLANS INDICATING LOCATION AND AREA SERVED FOR ALL DISTRIBUTION. 405.6.4.2 MANUALS. CONSTRUCTION DOCUMENTS SHALL REQUIRE THAT AN OPERATING MANUAL AND MAINTENANCE MANUAL BE PROVIDED TO THE BUILDING OWNER. THE MANUALS SHALL INCLUDE, AT A MINIMUM, THE FOLLOWING: 1. SUBMITTAL DATA STATING EQUIPMENT RATING AND SELECTED OPTIONS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE. 2. OPERATION MANUALS AND MAINTENANCE MANUALS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY IDENTIFIED. 3. NAMES AND ADDRESSES OF AT LEAST ONE QUALIFIED SERVICE AGENCY. NOTE: ENFORCEMENT AGENCIES SHOULD ONLY CHECK TO BE SURE THAT THE CONSTRUCTION DOCUMENTS REQUIRE THIS INFORMATION TO BE TRANSMITTED TO THE OWNER AND SHOULD NOT EXPECT COPIES OF ANY OF THE MATERIALS. EXTERIOR SITE EXTERIOR WALL 3-1/2" CONDUIT WITH PULL STRING TWO 10' LONG 5/8"0 CU. CLAD - GROUND RODS AIC CALCULATIONS AT WIREWAY L = LENGTH OF CIRCUIT TO FAULT = 100 FT I = AVAILABLE AIC AT CIRCUIT = 62,000 AMPS c = CONSTANT FROM TABLE 28,033 n = NUMBER OF WIRES PER PHASE = 2 C = CONSTANT c * n = 56,066 V = VOLTS = 208 VOLTS F = 1.732 * L * (I ,f C) * V = 0.921 M = 1 t`(1+F) = 0.521 AIC = I M 32,278 ANWS THESE CALACULAT IONS ARE BASED ON AN ESTRvLATED DISTANCE FROM THE TRANSFORMER TO 1ST MEANS OF DISCONNECT AND FEEDER WIRE SIZE. IF'LARGER FIRE IS USED OR THE DISTANCE (L) IS LESS THAN 100 FEET, THEN THE AIC VALUES WILL BE LARGER. CONT ACT ENGINEER FOR NEW CALCULATIONS. AIC CALCULATIONS' AT 400A MAIN #I DISCONNECT L = LENGTH OF CIRCUIT' TO FAULT 7 FT I = AVAff ABLE AIC AT CIRCUIT = 32,278 AMPS c = CONSTANT FROM TABLE = 28,033 n = NUMBER OF WIRES PER PHASE = I C = CONSTANT c * n = 28,033 V = VOLTS = 208 VOLTS F = 1.732 * L * (I J' C) * V = 0.067 M = lJ(I+F) = 0.937 AIC = I * M = 30,248 AMPS THESE CALACULATIONS ARE BASED ON AN ESTIMATED DISTANCE FROM THE TRANSFOICNI ER TO IST MEANS OF DISCONNECT AND FEEDER `i'IRE SIZE. IF LARGER WIRE IS USED OR THE DISTANCE (L) IS LESS THAN 7 FEET, THEN THE AIC VALUES WILL BE LARGER. CONTACT ENGINEER FOR NEW CALCULATIONS. RISER DIAGRAM- SCALE: � AIC CALCULATIONS AT 200A MAIN #2 DISCONNECT L = LENGTH OF CIRCUIT TO FAULT 7 FT I = AVAILABLE AIC AT CMCUIT = 32,278 AMPS c = CONSTANT FROM TABLE = 13923 n = NUMBER OF WIRES PER PHASE = I C = CONSTANT c * n = 13,923 V = VOLTS = 208 VOLTS F = 1.732 * L (I .F` C) * V = 0.135 M = I /(I+F) = 0881 AIC I * M = 28,435 AMPS THESE CALACULATIONS ARE BASED ON AN ESTIMATED DISTANCE FROM THE TRANSFORivIER TO IST MEANS OF DISCONNECT AND FEEDER WIRE SIZE. IF LARGER WIRE IS USED OR THE DISTANCE (L) IS LESS TILAN 7 FEET, THEN THE AIC VALUES WILL BE` LARGER. CONTACT ENGINEER FOR NEW CALCULATIONS. AIC CALCULATIONS AT 200A MAIN#3 DISC ECT L = LENGTH OF CIRCUIT TO FAULT = 7 FT I = AVAILABLE AIC AT CIRCUIT = 3278 AMPS c = CONSTANT FROM TABLE = 13,923 n = NUMBER OF WIRES PER PHASE = I C CONSTANT c * n = 13,923 V = VOLTS = 208 VOLTS F = 1.732*L*(ITC)*V = 0.135 M = i / (I + F) = 0.881 AIC. = I * M = 28,435 A'VIPS THESE CALACULAT IONS ARE BASED ON AN ESTIMATED DISTANCE FROM THE TRANSFORMER T O IST N E<ANS OF DISCONNECT AND FEEDER WIRE SIZE. IF LARGER WIRE IS USED OR THE DISTANCE (L) IS LESS `TFI.AN 7 FEET, THEN THE AIC VA LARGER. CONTACT ENGINEER FOR NTW CALCULATIO UES WILL BE NS. �1 TENANT SPACE n`` a �e t((a 1n i t rrrr,r� AV - No. 4 16 - TAT ®P At JUN 1 2023 BUCHANAN PE CONSUL TING INC. ELECTRICAL * MECHANICAL * PLUMBING EIVG/VEER/IVG 6191 W, ATLANTIC BLVD, SUITE# 2 MARGATE, FL 33063 Ph: 954-590-3300 Faxi 954-590-2232 Emit: BUCHANAN@MEPENGINEERS.C❑M CERTIFICATE OF AUTH❑RIZATI❑N # 8842 ❑RAJA BUCHANAN RE # 48916 Carlos Pizarro, R.A. AR - 0013079 Revisions: 1. REVISION 06-14-23 a� Z 0 _ � j 0 V� W� Li. 0 L W can LL Z �_ 0 W ZV Qa a� w _ (L w CO o E- 0 J ca U ®W �a Z � .-Z - .... P 0 W Wr Z 0 it °a M r- Q J 000 LLJ M a (� QZ0 0 0� �0� v Q �aU) �� _D at 0 cam U N LLl N 0 IZ Job Number: 22008.01 File name: Issued Date: Drawn by: Checked by: SHEET NAME ELECTRICAL RISER DIAGRAM SHEET NUMBER E-2