Loading...
HomeMy WebLinkAbout23-6219City of Zephyrhills 5335 Eighth Street Zephyrhills, FL 33542 Phone: (813) 780-0020 Fax: (813) 780-0021 ELCMISC-006219-2023 Issue Date: 10/19/2023 REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. before recording your notice of commencement." accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CC . TRACTOR SIGNATURE PE IT OFFICE PEW IT EXPIRES tft 6 M0A,;,TVITAOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER •.. ILA.• 5.6kW SOAR ARRAY PANS FOR JASON WAGNER 5651 6TH ST ZEPHYRHILLS, FLORIDA 33542 PROJECT DESCRIPTION: 14 MODULES - HYUNDAI: HIS-S400YH 14 INVERTERS - ENPHASE IOSPLUS-72-2-US GOVERNING CODES: 2020 FLORIDA PLUMBING CODE, 7TH EDITION 2020 FLORIDA BUILDING CODE, 7TH EDITION 2020 FLORIDA MECHANICAL CODE, 7TH EDITION NEC 2017 NFPA 1 2018 IN MODULE ROOF LAYOUT NTS WINDSPEED DESIGN DATA PER FBCR 2020 WIND SPEED 140 MPH RISK CATEGORY II EXPOSURE C GUST FACTOR f0.18 "A" DIMENSION 3 Ft ROOF PRESSURE FOR COMPONENTS AND CLADDING GABLE ROOF ZONE 1 +15.8 PSF -39.1 PSF ZONE 2E +15.8 PSF -39.1 PSF ZONE 2N +15.8 PSF -57.0 PSF ZONE 2R +15.8 PSF -57.0 PSF ZONE 3E +15.8 PSF -57.0 PSF HIP ROOF ZONE 1 +15.8 PST -35.5 PSF ZONE 2R +15.8 PSF -46.3 PSF ZONE 2E +15.8 PSF -49.8 PSF ZONE 3 +15.8 PSF -49.8 PSF I grR &s-�W:�45" GENERAL NOTES: 1. THIS IS TO CERTIFY THAT TO THE BEST OF MY KNOWLEDGE AND BELIEF, THESE PLANS CONFORM WITH FLORIDA BUILDING CODE 2020 WITH ALL SUPPLEMENTS AND ADDITIONS. 2. ALL PRODUCTS TO BE INSTALLED PER MANUFACTURER'S WRITTEN SPECIFICATIONS. I, ANDREW D. HALL PE# 87479 AN ENGINEER LICENSED PURSUANT TO CHAPTER 471, CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FBC, FBC 107. No. 79 0 a m w U U 00 o Z M � N mcli�2 o 3 m Q U V J r2 Z rn O o C �rCDo O J � Q— o H op wo= w U = M H U-) CV Z CV z MJ M w N" w Z � o CI H z DRAWING INDEX: o o W S-1 COVER C-D Z N S-2 ARRAY LAYOUT & DETAILS S-3 ELECTRICAL S-4 NOTES CO S-5 SPECIFICATIONS S-6 SPECIFICATIONS Li S-7 SPECIFICATIONS CD S-8 SPECIFICATIONS W. No. S-9 SPECIFICATIONS S-1 ...ee®M... EVEREST EC CLIP (TYP) 3/8"-16 X 3/4" HEX HEAD BOLT 3/8" - 16 FLANGE NUT PV MODULE -\ K2 SPLICE FOOT X/XL EVEREST IMC CLIP (2) 5/16° CIA. SS LAG SCREW 2- EVEREST CROSSRAIL 48-X EXISTING ROOF TRUSS �-EXISTING UNDERLAYMENi K2 SPLICE FOOT X/X 1l2" PLYWOOD (TYP) (2) 5/16" DIA SS LAG SCREW 2-1/2" EMBED MIN. TYPICAL SHINGLE ROOF ATTACHMENT NTS P /FRFU Ifd(` CI IP (TYP) i-YPICAL SHINGLE ROOF LAYOUT NTS NTS EVEREST CROSSRAIL 48-X (TYP) EVEREST EC CLIP (TYP) EVEREST EC CLIP (TYP) M. NO. S-2 L2 L1 METER 0 L1 NEUTRAL GROUND AC PANEL 200 AMP/240V #6 THWN-2 3/4" EMT, FMC, FOR EXTERIOR APPLICATION USE PVC OR LFMC/LFNMC CONDUIT #10 THWN-2 3/4" EMT, FMC, FOR EXTERIOR LOCKABLE FUSED APPLCATION USE PVC PV AC DISCONNECT OR LFMC/LFNMC CONDUIT 60A 240V 2-POLE #10 THWN-2 ENPHASE Q CABLE 30A RK-1 FUSE 3/4" EMT, FMC, FOR EXTERIOR Q-12-10-240 APPI CATION USE PVC% (TYP) OR LFMC CONDUIT/ NEUTRAL BONDED TO GROUND PER NEC 250.142(A)(3) L1 L2 N SPACE 20 20 SPACE 20 20 #6 GROUND NEUTRAL GROU ENPHASE IQ COMBINER 4 W/ (2) 20 AMP BREAKER NOTE: ALL INVERTERS ARE EQUIPPED W/ INTERNAL RAPID SHUTDOWN SYSTEM PER NEC 690.12 HYUNDAI: HIS-S400YH W/ ENPHASE IQ8PLUS-72-2-US INVERTER (TYP) AC MDC N0. 1 N0. 7 EVEREST CROSSRAIL 48-X (TYP) AC AC DCN I DCN NOTE: G NO. 1 NO. 7 ALL STRINGS TO HAVE TERMINATORS & SEALING CAPS SOLADECK COMBINER BOX INSTALLED PER MANUFACTURER'S #6 THWN-2 60OV/ NON -FUSED SPECIFICATIONS OR SOLTECTION RESIDENTIAL ENPHASE Q CABLE TRANSITION BOX Q-12-10-240 GEC BOND AT RACKING SYSTEM. — (TYP) (SEE NOTE #2) 0 � No. 79 _�3� S .441 O Q r m 0 U S U cD o J Z N co Z z w Q U m 0 0 V M z 0 0 H CD O�Q CO Q_ H L o W C5 r, Wv=Ln H -CD C9 N z N z M d M W N" W Z D O d Z) CD w LO U CD Z N O O w 7o < V) z U F- z w w U w o o LJ J at: 0 J U CL ¢ W M. NO. S-3 MODULE SPECIFICATION MODULE MAKE HYUNDAI MODULE MODEL HIS-S400YH FSEC CERTIFICATION # PMAX (STC) 400 W VOC (STC) 45.3 V VMPP (STC) 37.7 V ISC (STC) 11.3 A IMPP (STC) 10.6 A NOCT 45 C TC ISC 0.032 %/K TC VOC -0.27 %/K TC PMPP -0.35 %/K I OPERATING TEMP. -40-+85 C SAFETY LABELS AND MARKINGS GENERAL NOTES: 1. EQUIPMENT SUCH AS INVERTERS AND SOLAR MODULES HAVE PRE -APPLIED LABELS FOUND HEREIN SHALL BE APPLIED TO SUCH EQUIPMENT FOR INFORMATIONAL PURPOSES. 2. LABELS AND MARKINGS SHALL BE APPLIED TO COMPONENTS IN ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF NEC. 3. All REQUIRED PRODUCT SAFETY AND WARNING SIGNAGE SHALL BE UV RESISTANT OUTDOOR -RATED LAMINATED VINYL IN ACCORDANCE WITH ANSI Z535.4-2011. 4. ALL LABELS SHALL BE REFLECTIVE PER NFPA 11.12 SAFETY LABELS AND MARKINGS LEGEND A. LOCATION OF SERVICE DISCONNECTING MEANS. APPLY TO MAIN SERVICE DISCONNECTING MEANS AND PV DISCONNECTING MEANS AT POCC. MAIN SERVICE DISCONNECT MARKING A LABEL SHALL BE PERMANENTLY AFFIXED TO THE MAIN SERVICE DISCONNECT PANEL SERVING ALTERNATING CURRENT (AC) AND DIRECT CURRENT (DC) PHOTOVOLTAIC SYSTEMS. THE LABEL SHALL BE RED WITH WHITE CAPITAL LETTERS AT LEAST 3/4 IN, IN HEIGHT AND IN A NONSERIF FONT, TO READ: "WARNING: PHOTOVOLTAIC POWER SOURCE." THE MATERIALS USED FOR THE LABEL SHALL BE REFLECTIVE, WEATHER RESISTANT, AND SUITABLE FOR THE ENVIRONMENT. RAPID SHUTDOWN MEANS MARKING A PERMANENT LABEL SHALL BE AFFIXED ADJACENT TO THE CIRCUIT DISCONNECTING MEANS SERVING AC AND DC PHOTOVOLTAIC SYSTEMS. THE LABEL SHALL HAVE BE REFLECTIVE WITH ALL LETTERS CAPITALIZED AND HAVING A MINIMUM HEIGHT OF 3/8", IN A WHITE ON RED BACKGROUND THE LABEL SHALL BE CONSTRUCTED OF DURABLE ADHESIVE MATERIAL OR OTHER APPROVED MATERIAL. INVERTER SPECIFICATION INVERTER MAKE ENPHASE INVERTER MODEL IQ8PLUS-72-2-US MAX AC POWER OUTPUT 300 VA MAX. INPUT VOLTAGE 60 V NOM, DC VOLTAGE ® 240V 240 V NOM. AC VOLTAGE 25-58 V MAX. CONTINUOUS OUTPUT CURRENT 1.21 A MAX. DC CURRENT 15.0 A MAX. DC POWER (STC) 440 CEC EFFICIENCY 97 % N AN EMERGENCY CONTACT US SOLAR 1-800-351-3430 SOLAR PHOTOVOLTAIC SYSTEM Ai -WARNING- AUTHORIZED PERSONNEL ONLY RATED AC CURRENT: 21.2A NOMINAL AC VOLTAGE: 240V LOCATION: MAIN PV PANEL PHOTOVOLTAIC DISCONNECT Ai -WARNING- ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. LOCATION: AC DISCONNECT(S) NOTES: 1. ALL ASPECTS OF THE ELECTRICAL WORK REQUIRED TO COMPLETE THE PROJECT REPRESENTED IN THIS DOCUMENT SHALL COMPLY WITH THE MANUFACTURERS RECOMMENDATIONS/SPECIFICATIONS AND ALL CODES, STATUES AND STANDARDS ADOPTED BY THE STATE AND THE LOCAL AUTHORITY HAVING JURISDICTION, 2. ALL COMPONENTS MUST BE GROUNDED PER NEC 690.43. 3. ALL EQUIPMENT SHALL BE LISTED PER NEC 690.4(D). 4. THE INFORMATION PROVIDED IN THESE DOCUMENTS IS NOT EXHAUSTIVE. IT REMAINS THE CONTRACTORS RESPONSIBILITY TO ACHIEVE THE PROPOSED INSTALLATION, IN FULL EXERCISE OF AND COMPLIANCE WITH THE ITEMS IDENTIFIED IN NOTE 1. 5. PER NEC 690.17 PROVIDE A WARNING SIGN AT ALL LOCATIONS WHERE TERMINALS OF THE DISCONNECTING MEANS BE ENERGIZED IN THE OPEN POSITIONS. SIGN SHALL READ "WARNING -ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS - TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION OR EQUIVALENT. 6. PER NEC 705,10, PROVIDE A PERMANENT PLAQUE OR DIRECTORY SHOWING ALL ELECTRIC POWER SOURCES ON THE PREMISES AT SERVICE ENTRANCE. 7. INTERCONNECTION METHOD SHALL COMPLY WITH NEC 705.12. 8. PV METER MAY OR MAY NOT BE REQUIRED BY THE AHJ AND/OR UTILITY FOR INTERCONNECTION. 9. CONDUCTOR SIZING OF THIS DESIGN IS BASED ON RACEWAYS LOCATED OUTSIDE ATTICS OR NOT EXPOSED TO DIRECT SUNLIGHT. WHERE TWO DIFFERENT AMPACITIES APPLY TO ADJACENT PORTIONS OF A CIRCUIT, THE HIGHER AMPACITY SHALL BE PERMITTED TO BE USED BEYOND THE POINT OF TRANSITION, A DISTANCE EQUAL TO 3.OM (10ft) OR 10 PERCENT OF THE CIRCUIT LENGTH FIGURED AT THE HIGHER AMPACITY, WHICH EVER IS LESS. NEC 310.15 (B)(2) 10.ALL CONDUCTORS AND RACEWAYS SHALL BE SUPPORTED ON INTERVALS AND BY METHODS REQUIRED BY THE NEC. 11. LINE TAPS TO BE MADE WITH ILSCO KUP-L-TAP INSULATION PIERCING CONNECTOR. 12. GFI BUILT IN TO ALL INVERTERS. SAFETY LABELS Ai -WARNING- ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED AUTHORIZED PERSONNEL ONLY LOCATION: DISCONNECTS, INVERTERS, JUNCTION BOXES, OTHER ENCLOSES HOLDING DC CONDUCTORS EMERGENCY RESPONDER: THIS SOLAR PV SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO w PR�Ii]S C THE "OFF' POSITION TO SHUT DOWN LAJ_ ENTIRE PV SYSTEM V V) z o O M H O Q ono Q_ ZWo� H 00 LIJ H Lo U V{ N Z N z ro w V� w Z 7-) o O' 0- z N W U Z N 0 C)i,.i Lo ¢ � V) z r- w w N w W of 0 U D_ ¢ Z W. NO. S-4 c11 A... Electrical Characteristics 385 390 395 400 405 410 ..... 44,5 44 8 ....... 45 0 45 3 45.6 __. - 45 9 ® ......... 11,04 11.11 ........_ ....... 11.18 11.25 11,33 11.40 � 37,1 37.3 37.5 37.7 37,9 381 ............ .. .............................................. 70.40 ........... ...... .__-.. .................................. 10.54 10.61 ..-......... .. ..... ..... Yfl.76 .._..... .............................10.47 19.3 ............................. 19,5 ............................ .........................................................10.69 19,8 20.0 ............................ 20.3 ......__.... 20.5 ... Mono crystaIluta 9busbar '--'--.. __... _ 1,500 — ... .._. 0.347 - -- ii ... ... .. -D.266 .. ... ... .... ... ...... _ __..__... ... - ... +0.032 ........... .... *Al data at STC IMeaslramerr tole does PmpP t"s%; Ise We data trey W changed without prior notice 399 404 410 415 425 431 ......... ......... ......... ...................... .................. ......... ... ............... ........................... 437 443 449 454 466 472 y/ ..................... 475.........................._.........482.................._..................488.....................................494......................................506................._....................513 ................... Mechanical Characteristics installation Safety Guide • Only qualified personnel should install or r 1,038mm(W)x1,924mm(L)x35mill perform maintenance. .............................................................................._..__................ APProx.21.1 kg Be aware of dangerous high DC ve tage. • Do no damage or scratch the rear surface 132 half curt bifacial cells (2 parallel x 66 half cells in series) of the module. ..................... -..... ............... _......._................................ ._............................................................... ..................... _......... -.......... Do not handle or install modules when they L t Cable: 1,200mm/4mm2 are w 1. Connector: MC4 genuine connector .. .....' .......... .... Nominal Operating 45.5'G±2 IP68, weatherproof, IEC certified (UL listed) Cei.. Temperature ... ......-...... .._.... .........._-.................................................................__....................._................. Operating Temperature -401 -+85'C 3 bypass diodes to prevent power decrease by partial shade Maximum ......... .................. System Voltage DC 1,100V Front: 3.2mm, High Transmissiorl CoateclTempered Glass Maximum ................... ...,,,,,,.. ........... Eacapsulant EVA I Back Sheet: Black Meshed Transparent Backsheot Reverse Current 20A ... .. ........... ....... ... ....... ............ ............ ... Anodized aluminum alloy type 6063 Maximum Front54C Pa I3c ,f; Test Load...........................................__Rea r 4,000 Pa B 4 p.')........_...... Module Diagram (unit:m ., i-V Curves Front Side View Rear Side View Current [Al tz Oil I e 14i i IIII I I I' I tc -1il III IIII i ' I I I I � . NiflIVIIIIII10111111 11 It 11 M 11111,111111JI: I1 II �iI t l i 8 I I 8 t}} 1 II IIII It 1i Irradian 1000W/m' -ocearecallr P s°c 1 ,111111111 It -:0ce n 90,uT n zs•c 8 _ ._.. Opzratlng Cell Temp=85°d { t d jll Ifll 11�711111 111111 C - ° o to 20 30 40 so 1111111 m lllllll �RI lllllll V°¢agely] Illllu lllllll III 11.1111 IIIIJu Il1Rl. I UI l 11 I i Current [A] i12 1 ,0.a to 'mad bred t 000w/ 038-i. __35t03 20 5, 0.5 6 � Wid Mad 680WW 12—O�StOTT,m, r'1 d TL _,. Nei I.lrtad—VMIW ' itGi T mue Iliad = zoow/m= a to zo 3o w w nETAIL A DETAIL B SECTION C-C' 8 D-D' VoltegelVl :c0afrtandNWPki` %'AHYUNDAI ENERGY SOLD IONS IQ8 and IQ8+ Microinverters Module compatibility MPpTvoltagerange Operating range Min/max start voltage Max input DC voltage Max DC rltrrent',jmodule Is Overvoltage class DC port DC port ha0kfead current PV array configuration Ambient temperature is Relative humidity range DC Conmctortype Dimensions (HxWxD) Weight Cooing Approved for wet Iocatl Acoustic noise at 1 in Pgllutiondegree, Enclosure (1) No enforced DC/AC ratio. See the compatibility calculator at https://Iink.enphase.com/ module -compatibility (2) Maximum continuous input DC current is 101(3) Nominal voltage range can be extended beyond nominal If required by the utility. (4) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQ8SP-DS-0002-01-EN-US-2021-10-19 c0 0 � I Z cV 00 m o z¢ LitLjj z Q Q N �p To Z o r7 o ¢ cD Lo J t — Z W d� H CI 00 W O - Lip t1J U = d HLnU.� Vt N Z CV M Of LC") W N" ILL)z o d H Z D No W O z III- j 3 t- U z to S z w Q0 O o ¢ to z U tit ITU (n _ U U a ¢ to DWG. NO. S-5 . IF Enphase Q Cable Accessories O AGGREGATOR SPECIFICATIONS Q Commercial Aggregator Q-BA-3-3P-35 (three-phase).. Combines up to three, single-phase micro nverier branches into a three phase home run, Protect with maximum nil A, 3-pole QCPD. € 0nfi ,?�' 3.d`n (Q tYtihr { 17 %rs i1�U) x iisi (i'�) ,,2':in f Nll ',fir, ��y� / .rya r_ .' i:�„ „H>,> ., �,.. , .,_ ._ .:,.a ... if Homerun conductor size range #12to #4 AWG Temperature range -40` C to +55` C (-40' F to+122' F) monde tiasserttbtckodir�aL67tt b ltchead canilac�s', \ ' .........,. ., ,,,.,,/�� ....... ems/, . - . ;.. ,.�.. ,... . , , ,..�., •• CONDUCTOR SPECIFICATIONS C� t trort> 'c y; r i 1 �� 4 E r L g Icitts'fa"asserrrE)lltrs DC, caEale � , . "' Flame test rating FT4 5r pt(ataca LX !wv"r u; �t E t# es€sta t# cornbac ad tt�for thetJnited.'tates WAN_ ... ... Conductor type THHN/THWN-2 dry/wet DiaoaY a t \ toar,s y t ulfi'd cc€otgrshave beenewatuaietl and approred layt tritse asthe load break �/1' Eref% No '69t �` Q CABLE TYPES !ORDERING OPTIONS Model Number Max Nominal Voltage Connector Spacing PV Module Orientation Connector Count per Box Pfi Q-12-17-240 277 %'AC 2.0 m (6.5 ft) Landscape (60-cetl) 240 1-'1-Lq 263 o y /,, / , 2771iRQ / 75 ft % l tldsca °ie 72 oa[1- flU >F... - '• „ Kam...,. \\�\.';,, . ,: /r, ., ,,,./, >„ „r „ �, ,'! ; ENPHASE O GABLE ACCESSORIES Name Model Number Description It <, , 2� rs cf t, G cab e i__no 00 � r ,. .li.;auW Field-wireable connector (rtlale) Q CONN 10M Bake connections from any Q Aggregator open connector' i .3, 5t . ,:,, ,' > ; G ;;I ' c rr ect4.. r , a u ei1 a_ n „ Q h� _ Y Cable Clip Q-CLIP-100 Used to Paster, cablingto the racking or to secure looped cabling %Olseonnedi:Cq) I#tSC-1 Cdolft r Q Ca61e oor€nectt r bC Connectors host C modt le r 'y :..< ,...... via.,...... , uru,..,,, � .. ....... QA93ra -a-te sealing caps (male ) Q-BA CAR- Q Sealing cap for unused aggregator connections Q Qa6161eang c ps (fez ai i O ��� � e e detlto sof e y h unused c r actorurn ilea abJlhq "Terminator Q-TERM-10 Terminator cap for unused cable ends Rapiacme3 i daptor (M� _ u �4r f�4t 1�41t 3rgE 9) i Replacement DC Adaptor (UTX) Q-DC;C-5 DC adaptor to €Sl X (max voitagct 100 VDC, TERMINATOR SEALING CAPS Terminator cap for unused cable Sealing caps for unused aggregator ends, sold in packs of ten • and cable connections c:::] (Q-TERM-10) (Q"BA-CAP-10 and Q SEAL 1(I) i I DISCONNECT TOOL CABLE CLIP Plan t o use at least one per -,�. , e ' -. _.__ Js.dtofa fasten 1"n t racking i D � _, ste cabling .othe, � ,, g T installation, sold in packs of ten or to secure looped cabling,sold in 1 (Q.DISC-10) `! packs often (Q-CLIP-100) To learn more about Enphase offerings, visit enphase.com 2018 -mhase Energy. a i � iyhts rase wed All trademarks or brands used are tl•e properly f Fniphae En .1f Inc. C Enphase IQ Combiner 4, I Combiner 4C XIQ AM1-240-4 C) IQ Combiner 4C with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI CI'2.20+i-t?.5 <) and consurnption monitoring includes Enphase Mobile Connect cellular modem (CELLMgDEM-Mt-06-SP-05', a plug -and -play Industria€-grade cell modem for systems up to 60 microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, wwherathere is adequate cellular service in the installation area.) includes a Over solar shield to match the IQ Battery end IQ Systetr Controller and to deflect heat. ACCESSORIES AND REPLACEMENT PARTS (not included, order separately) Circuit Breakers Supports Eaton BR210, BR215, BR220, BR230, BR240, BI2250, and BR26G ci`cult breakers. BRK10A 2-240V Circuit breaker, 2 pole, "CA, Eaton BR210 BRK-15A 2-240V Circuit breaker, 2 pole, I5A, Eaton BR215 BRK-20A-2P 240V Circuit breaker, 2 pole, 20A, Eaton BR220 BRK-15A4 '-240V-B Circuit breaker, 2 pole, 15A, Eaton: BR2156 with hold down kit support BRK-201 P 24r .� B Circuit breaker, 2 pole, 20A, Paton BR 2013 with hold down kit support .'. D' �` r,€�it s, j k re € 81?'T I%alYi✓�.sr \ .9 N ..... ....:>....`*...Pa:�s///i �..._..:. _ .-.->.__.�.-..�..11..,.��-,....,,.,. 11 XA-SOLARSH:ELD-ES Replacement solar shield for IQ Corbiner 4i40 XA-ENV PCBA 3 Replacement IQ Gateway pi inted circuit board (PCl3t for 'ombirer A/4C re G 1aoA �f! �!� , . , �i'V .. i•Foltl dt,�r's kaffot Eaten'a qt ixracatithlrurs , `"� /3`� ELECTRICAL SPECIFICATIONS w I .Pfetrn-" n t3-bu " System voltage 120,1240 VAC 6 Hz c fdtot5'� Rsenos't5.tsftar cairn ' F ', ., ir'2rS A".:: .. r Max continuous current rating 65 A tvYax.€'bntrrr�sou WrtenirarFLlgIilAu€'hocnPflr`s%ra '` 64A�\r Max. fu /cr titrsting(output) 90A ...� -, ,' E..r '; C1 v'urtb (ailar, artdlm'r u +ar {3'e U ib foie€ 2 (J 31 E'E3tC?n BP: en£`a'',l1t�'Iblied iy"en2rat€�on {�,.�i;) bE67le r5J`liY ("46't liYLti35le{f a / 4 „G„!drib., / Max. total branch circuit breaker rating (input) BOA of distributed generation. i 95A with IQ Gateway breaker included m YodsetMY l 1EX, /n 4As,4:...ad. cone 'atewaY ,; /ii,✓„' „ >. , / :a 'r __ .w Consun utio , nonitoring CT (CT-200-SPI..€T) A pair of 200 A split core cunenttransfermers MECHANICAL DATA Dt°neeastcnS�iiab) � / /' 37�tf445x16B€fn(1A75 xd��>{6,6 ) &ler€uhics2li'6 t�35€rrs)�trttEr€rortntittgbra�ke2.�/'H%r�' � ,�4->. WoigM 7.5 kg (16.5les) Cooling Natural convection plush at shield Ea:o€6sdte anv3ronrzx�n2at fatrnj z _ v - C3uftde "4RTi, cerilT(ed NEMA2 ge RR poi'yp'arUct(%�at�rui Wire sizes 20 A to 5.0 A breaker inputs: 14 to 4 AWO copper conductors • 60 A breaker branch input:4 to tin AWC copper conductors • Main lug combined output: 10 to 2i0AWG copper conductors • Neutral and ground: 14to1i0copper conductors Always follow local code requirements for conductor sizing. INTERNET CONNECTION OPTIONS me f)ierJ YF j-ot "0", S5Sibtgfse .a� r , , ��ric: r , Cellular- ... .. CEl LMO€JEM, PAI-06SP OS CEI. LIAO€i EM M1-06 AT 05 (4C based I rE. MI cellular moder:e). Note that all EnPh se Mobile Correct cellular modern is ter.uiree for all Ense-nt) e installations. fit° ` _. opto ai Bp2 at5 (rCat � T(tEfhrme € ble (oatr El 4gd) .:'. COMPLIANCE Comoliance, IQ Gateway UL 6060 I-1 /CANCSA 22.2 No. 61010=1 To learn more about Enphase offerings, visit enphase.colTl To P HAS E> 202' Dn:-Ile so, .ncrce r-.hd.:-c-,_r ed.E.nnha^, t e:.rpF x o; ,<..o ':.,men .4 ,and otlhei a P.,are. trrAernaiksof Dat2 s.:b o- to change "-2 1-2lD2: V V) M Z o O�...r M r C i O V% ¢ o ZwOoM�t d- H W CD W v = � Z t� M kD V1 N Z N Z �M w w z � O Z p W o CD � z N CD rn Z w ern CD 2 N U U N Li U w Q CL U a < V) DWG. W. S-6 Assembly 0 0 Corner Out and mark array 46 4.VA I** 0 nark on roof. "ay Snap chalk lines for rail shingle 6! location within shingle dft , m Course. [Refer to module Affiff— ,me If" manufacturer frame '0 clamping zonesj, Mark'mounting locations over rafters and chalk lines within shingle course, Refer to engineering letters for allowable mount spacing. O we tj AW� �Y or oeck attachments, follow steps in 2a, but only use Splice Foot screws in the four corners of the mount. When possible always attach mounts to the rafter and only use deck attached as a secondary option when a 'tp rs a re n Dt wl th 1 n rno u ntl n g zo no s fo r th a a rray. Fo flow K2 an g I nee re d ca I culatio ns a no spa n cha rts fo r d e cl< attpchments. When deck attaching chock for positive engagement into Plywood and avoid plywood seams. INFO, Pin"neven,Roo SurfB of an additiona, piece or uq a standard crimp 'igle starter course, leval f surface under the ce Foot. a videj on mount leveling I so- refer to Splice Foot V 'Z Dilation video: https,,// youtube.corn/c/ ystemsusNix A z �10 '01 X �w I F- M Z N 00 Z CD yj Z 3 H Q m 0 N O V �.i M z QD GD } CD CD O J CM Q _ co W O W U = H Lo C-D V{ N Z N Z M IZ W V" W Z D O d H Z D o w O C-D U Z N LO O H < co Ln Z C. ID N Q � U Li U O O U-I J m n- U C I (n DK. NO. S-8 HYUNDAI SOLAR MODULE YH Dual Black Max HiS-S385YH(BK) HIS-S390YH(BK) HiS-S395YH(BK) SERIES HiS-S400YH(BK) HiS-S405YH(BK) HiS-S410YH(BK) Bifacial Cells More Power UL 1,500V All black Module Generation 7EC 1.504V or Sleek Design In Low Light Saves BOS Costs (Black Meshed - Backsheet) • Mounting systemsfor solar technology �f item CrossRail 48-X Technical Data Sheet Overview: •,� Maximized Power ". Generation Half -Cut & Multi -Wire Technology 9 Wires a///���l•••���p —L)— Anti -LID / PID �� Increased total power output through Improved current flow with half -cut Both LID(Light Induced Degradation) and capturing light from both the front and technology and 9 thin wiring technology PID(Potential Induced Degradation) are back of Bifacial solar modules. Back side allows high module efficiency of up to significantly reduced to ensure higher power gain up to 25% of the front output 20.5%. It also reduces power generation actual yield during lifetime. depending on PV system design. loss due to micro -cracks. i i Mechanical Strength UL / VDE Test Labs QQ Hv Reliable Warranty Tempered glass and reinforced frame Hyundai's R&D center is an accredited test Global brand with powerful financial design withstand rigorous weather laboratory of both UL and VDE, strength provide reliable 25-year conditions such as heavy snow(5,400Pa) warranty. and strong wind(4,000Pa), Hyundai's Warranty Provisions About Hyundai Energy Solutions 25-Year Product Warranty vacs • Materials and w-orkmanshp Established in 1972, Hyundai Heavy Industres. Group is one of the most trusted names in the hearty industries sector and is a Fortune 500 company. As a global leader and innovator, Hyundai Feaw Industries is committed tobuilding a future arowth er:g;:^.e by developing andinvesting 25 25-Year Performance Warranty heavily n the field of renewabie energy. reacts •Initial year: 98.i:'-/„ As a core energy business entity o* ![Hl, iIyunuai _nergy Solutions has stror:g pride ir: providir:g Linear warranty after second year high -qua ay IN products to more than 3,000 customers .vorld•-wide. with 0.54%p annual degradation. 85.0'% a yuarantel.,ci up (aa 25 years Certification ML US LISiEO 11.51731, cerlzl:ed by UL. Type tifor Flue C as4 N vw of hvundai.e--ca.kr z�Gi� , ENERGY SOLUTIONS MECHANICAL PROPERTIES Material: 6000 Series Aluminum Ultimate Tensile Strength: 37.7 ksi (260 MPa) Yield Strength: 34.8 ksi (240 MPa) Weight: 0.56 IbsAt. (0.833 kg/m) Finish: Mill or Dark Anodized SECTION PROPERTIES Sx: 0.199 in3 (3.261 cm3) Sy: 0.153 in3 (2.507 cm3) A (X-Section): 0.467 in2 (3.013 cm2) General Dimensions: IP9] [4216.40] r —1 1.54 I 166 f `48] 1.89 t , l Dimensions in [mm] Inches Notes: to Structural values and span charts determined in accordance with Aluminum Design Manual and ASCE 7-10 0- UL2703 Listed System for Fire and Bonding CrossRail 48-XTechnical Data Sheet US1-0817 @ LISTED OL ti vo No. 8 9 r • 441 e r : S Wa i • Q '• ��o A,<nl�Po�'+� ttttlt7 77i 1! J 0 m Y U W U WoW � JCN ~ M 00 Z N nCNo z z 3 m a o N o V _.1 � M Z rn O CZ) r0 O J � Q _ Z ckf 00 W O W c-5 H CD Vt N Z N Z�'�t�i w N" w z o O F-1 Z o w � 3 z N o = Z w O < O (/7 Z U U � Lam. U w C) �p W = a- V) U DWG. N0. S-9