ELCMISC-006219-2023
Issue Date: 10/19/2023
REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection, whichever is greater, for each subsequent reinspection.
Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies.
before recording your notice of commencement."
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CC . TRACTOR SIGNATURE PE IT OFFICE
PEW IT EXPIRES tft 6 M0A,;,TVITAOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
•.. ILA.•
5.6kW SOAR ARRAY PANS
FOR
JASON WAGNER
5651 6TH ST
ZEPHYRHILLS, FLORIDA 33542
PROJECT DESCRIPTION:
14 MODULES - HYUNDAI: HIS-S400YH
14 INVERTERS - ENPHASE IOSPLUS-72-2-US
GOVERNING CODES:
2020 FLORIDA PLUMBING CODE, 7TH EDITION
2020 FLORIDA BUILDING CODE, 7TH EDITION
2020 FLORIDA MECHANICAL CODE, 7TH EDITION
NEC 2017
NFPA 1 2018
IN
MODULE ROOF LAYOUT
NTS
WINDSPEED DESIGN DATA PER FBCR 2020
WIND SPEED
140 MPH
RISK CATEGORY
II
EXPOSURE
C
GUST FACTOR
f0.18
"A" DIMENSION
3 Ft
ROOF PRESSURE FOR COMPONENTS AND CLADDING
GABLE ROOF
ZONE 1
+15.8 PSF
-39.1 PSF
ZONE 2E
+15.8 PSF
-39.1 PSF
ZONE 2N
+15.8 PSF
-57.0 PSF
ZONE 2R
+15.8 PSF
-57.0 PSF
ZONE 3E
+15.8 PSF
-57.0 PSF
HIP ROOF
ZONE 1
+15.8 PST
-35.5 PSF
ZONE 2R
+15.8 PSF
-46.3 PSF
ZONE 2E
+15.8 PSF
-49.8 PSF
ZONE 3
+15.8 PSF
-49.8 PSF
I grR &s-�W:�45"
GENERAL NOTES:
1. THIS IS TO CERTIFY THAT TO THE BEST OF
MY KNOWLEDGE AND BELIEF, THESE PLANS
CONFORM WITH FLORIDA BUILDING CODE 2020
WITH ALL SUPPLEMENTS AND ADDITIONS.
2. ALL PRODUCTS TO BE INSTALLED PER
MANUFACTURER'S WRITTEN SPECIFICATIONS.
I, ANDREW D. HALL PE# 87479 AN ENGINEER
LICENSED PURSUANT TO CHAPTER 471, CERTIFY
THAT THE PV ELECTRICAL SYSTEM AND
ELECTRICAL COMPONENTS ARE DESIGNED AND
APPROVED USING THE STANDARDS CONTAINED IN
THE MOST RECENT VERSION OF THE FBC, FBC
107.
No. 79
0
a
m
w
U
U
00
o
Z
M
�
N
mcli�2
o
3
m
Q
U
V
J
r2
Z rn
O o
C
�rCDo
O J �
Q—
o
H
op
wo=
w U =
M
H U-)
CV Z CV
z MJ M
w N"
w Z
� o
CI
H
z
DRAWING INDEX:
o
o
W
S-1 COVER
C-D
Z
N
S-2 ARRAY LAYOUT & DETAILS
S-3 ELECTRICAL
S-4 NOTES
CO
S-5 SPECIFICATIONS
S-6 SPECIFICATIONS
Li
S-7 SPECIFICATIONS
CD
S-8 SPECIFICATIONS
W. No.
S-9 SPECIFICATIONS
S-1
...ee®M...
EVEREST EC CLIP
(TYP)
3/8"-16 X 3/4" HEX HEAD BOLT
3/8" - 16 FLANGE NUT
PV MODULE -\
K2 SPLICE FOOT X/XL
EVEREST IMC CLIP
(2) 5/16° CIA. SS LAG SCREW
2-
EVEREST
CROSSRAIL 48-X
EXISTING ROOF TRUSS �-EXISTING UNDERLAYMENi K2 SPLICE FOOT X/X
1l2" PLYWOOD (TYP)
(2) 5/16" DIA SS LAG SCREW
2-1/2" EMBED MIN.
TYPICAL SHINGLE ROOF ATTACHMENT
NTS
P /FRFU Ifd(` CI IP
(TYP) i-YPICAL SHINGLE ROOF LAYOUT
NTS
NTS
EVEREST
CROSSRAIL 48-X
(TYP)
EVEREST EC CLIP
(TYP)
EVEREST EC CLIP
(TYP)
M. NO.
S-2
L2 L1
METER
0
L1
NEUTRAL GROUND
AC PANEL 200 AMP/240V
#6 THWN-2
3/4" EMT, FMC, FOR EXTERIOR
APPLICATION USE PVC OR
LFMC/LFNMC CONDUIT #10 THWN-2
3/4" EMT, FMC, FOR EXTERIOR
LOCKABLE FUSED APPLCATION USE PVC
PV AC DISCONNECT OR LFMC/LFNMC CONDUIT
60A 240V 2-POLE #10 THWN-2 ENPHASE Q CABLE
30A RK-1 FUSE 3/4" EMT, FMC, FOR EXTERIOR Q-12-10-240
APPI CATION USE PVC% (TYP)
OR LFMC CONDUIT/
NEUTRAL
BONDED TO
GROUND
PER NEC
250.142(A)(3)
L1
L2
N SPACE 20
20
SPACE 20
20
#6 GROUND NEUTRAL
GROU
ENPHASE IQ COMBINER 4
W/ (2) 20 AMP BREAKER
NOTE:
ALL INVERTERS ARE EQUIPPED
W/ INTERNAL RAPID SHUTDOWN
SYSTEM PER NEC 690.12
HYUNDAI: HIS-S400YH
W/ ENPHASE IQ8PLUS-72-2-US
INVERTER (TYP)
AC MDC
N0. 1 N0. 7
EVEREST CROSSRAIL
48-X (TYP)
AC AC
DCN I DCN NOTE:
G NO. 1 NO. 7 ALL STRINGS TO HAVE
TERMINATORS & SEALING CAPS
SOLADECK COMBINER BOX INSTALLED PER MANUFACTURER'S
#6 THWN-2 60OV/ NON -FUSED SPECIFICATIONS
OR
SOLTECTION RESIDENTIAL ENPHASE Q CABLE
TRANSITION BOX Q-12-10-240
GEC BOND AT
RACKING SYSTEM. — (TYP)
(SEE NOTE #2)
0 �
No. 79
_�3� S
.441
O
Q
r
m
0
U
S
U
cD
o
J
Z N
co
Z z
w
Q U m
0 0
V
M
z
0 0
H
CD
O�Q
CO
Q_
H L o
W C5 r,
Wv=Ln
H -CD
C9 N z N
z M d M
W N"
W Z
D O
d
Z)
CD w
LO
U CD
Z N
O
O w 7o
<
V) z U
F-
z w w U
w o o LJ
J at: 0 J
U CL ¢ W
M. NO.
S-3
MODULE SPECIFICATION
MODULE MAKE
HYUNDAI
MODULE MODEL
HIS-S400YH
FSEC CERTIFICATION #
PMAX (STC)
400
W
VOC (STC)
45.3
V
VMPP (STC)
37.7
V
ISC (STC)
11.3
A
IMPP (STC)
10.6
A
NOCT
45
C
TC ISC
0.032
%/K
TC VOC
-0.27
%/K
TC PMPP
-0.35
%/K
I OPERATING TEMP.
-40-+85
C
SAFETY LABELS AND MARKINGS GENERAL NOTES:
1. EQUIPMENT SUCH AS INVERTERS AND SOLAR MODULES HAVE
PRE -APPLIED LABELS FOUND HEREIN SHALL BE APPLIED TO SUCH
EQUIPMENT FOR INFORMATIONAL PURPOSES.
2. LABELS AND MARKINGS SHALL BE APPLIED TO COMPONENTS IN
ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF NEC.
3. All REQUIRED PRODUCT SAFETY AND WARNING SIGNAGE SHALL BE UV
RESISTANT OUTDOOR -RATED LAMINATED VINYL IN ACCORDANCE WITH
ANSI Z535.4-2011.
4. ALL LABELS SHALL BE REFLECTIVE PER NFPA 11.12
SAFETY LABELS AND MARKINGS LEGEND
A. LOCATION OF SERVICE DISCONNECTING MEANS. APPLY TO MAIN
SERVICE DISCONNECTING MEANS AND PV DISCONNECTING MEANS AT
POCC.
MAIN SERVICE DISCONNECT MARKING
A LABEL SHALL BE PERMANENTLY AFFIXED TO THE MAIN SERVICE
DISCONNECT PANEL SERVING ALTERNATING CURRENT (AC) AND DIRECT
CURRENT (DC) PHOTOVOLTAIC SYSTEMS. THE LABEL SHALL BE RED WITH
WHITE CAPITAL LETTERS AT LEAST 3/4 IN, IN HEIGHT AND IN A
NONSERIF FONT, TO READ: "WARNING: PHOTOVOLTAIC POWER SOURCE."
THE MATERIALS USED FOR THE LABEL SHALL BE REFLECTIVE, WEATHER
RESISTANT, AND SUITABLE FOR THE ENVIRONMENT.
RAPID SHUTDOWN MEANS MARKING
A PERMANENT LABEL SHALL BE AFFIXED ADJACENT TO THE CIRCUIT
DISCONNECTING MEANS SERVING AC AND DC PHOTOVOLTAIC SYSTEMS.
THE LABEL SHALL HAVE BE REFLECTIVE WITH ALL LETTERS CAPITALIZED
AND HAVING A MINIMUM HEIGHT OF 3/8", IN A WHITE ON RED
BACKGROUND THE LABEL SHALL BE CONSTRUCTED OF DURABLE
ADHESIVE MATERIAL OR OTHER APPROVED MATERIAL.
INVERTER SPECIFICATION
INVERTER MAKE
ENPHASE
INVERTER MODEL
IQ8PLUS-72-2-US
MAX AC POWER OUTPUT
300
VA
MAX. INPUT VOLTAGE
60
V
NOM, DC VOLTAGE ® 240V
240
V
NOM. AC VOLTAGE
25-58
V
MAX. CONTINUOUS OUTPUT CURRENT
1.21
A
MAX. DC CURRENT
15.0
A
MAX. DC POWER (STC)
440
CEC EFFICIENCY
97
%
N AN EMERGENCY CONTACT
US SOLAR
1-800-351-3430
SOLAR PHOTOVOLTAIC SYSTEM
Ai
-WARNING-
AUTHORIZED PERSONNEL ONLY
RATED AC CURRENT: 21.2A
NOMINAL AC VOLTAGE: 240V
LOCATION: MAIN PV PANEL
PHOTOVOLTAIC DISCONNECT
Ai
-WARNING-
ELECTRIC SHOCK HAZARD
DO NOT TOUCH TERMINALS. TERMINALS ON
BOTH THE LINE AND LOAD SIDES MAY BE
ENERGIZED IN THE OPEN POSITION.
LOCATION: AC DISCONNECT(S)
NOTES:
1. ALL ASPECTS OF THE ELECTRICAL WORK REQUIRED TO COMPLETE THE PROJECT REPRESENTED IN THIS DOCUMENT
SHALL COMPLY WITH THE MANUFACTURERS RECOMMENDATIONS/SPECIFICATIONS AND ALL CODES, STATUES AND
STANDARDS ADOPTED BY THE STATE AND THE LOCAL AUTHORITY HAVING JURISDICTION,
2. ALL COMPONENTS MUST BE GROUNDED PER NEC 690.43.
3. ALL EQUIPMENT SHALL BE LISTED PER NEC 690.4(D).
4. THE INFORMATION PROVIDED IN THESE DOCUMENTS IS NOT EXHAUSTIVE. IT REMAINS THE CONTRACTORS
RESPONSIBILITY TO ACHIEVE THE PROPOSED INSTALLATION, IN FULL EXERCISE OF AND COMPLIANCE WITH THE
ITEMS IDENTIFIED IN NOTE 1.
5. PER NEC 690.17 PROVIDE A WARNING SIGN AT ALL LOCATIONS WHERE TERMINALS OF THE DISCONNECTING
MEANS BE ENERGIZED IN THE OPEN POSITIONS. SIGN SHALL READ "WARNING -ELECTRIC SHOCK HAZARD - DO
NOT TOUCH TERMINALS - TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN
POSITION OR EQUIVALENT.
6. PER NEC 705,10, PROVIDE A PERMANENT PLAQUE OR DIRECTORY SHOWING ALL ELECTRIC POWER SOURCES ON
THE PREMISES AT SERVICE ENTRANCE.
7. INTERCONNECTION METHOD SHALL COMPLY WITH NEC 705.12.
8. PV METER MAY OR MAY NOT BE REQUIRED BY THE AHJ AND/OR UTILITY FOR INTERCONNECTION.
9. CONDUCTOR SIZING OF THIS DESIGN IS BASED ON RACEWAYS LOCATED OUTSIDE ATTICS OR NOT EXPOSED
TO DIRECT SUNLIGHT. WHERE TWO DIFFERENT AMPACITIES APPLY TO ADJACENT PORTIONS OF A CIRCUIT, THE
HIGHER AMPACITY SHALL BE PERMITTED TO BE USED BEYOND THE POINT OF TRANSITION, A DISTANCE EQUAL TO
3.OM (10ft) OR 10 PERCENT OF THE CIRCUIT LENGTH FIGURED AT THE HIGHER AMPACITY, WHICH EVER IS LESS.
NEC 310.15 (B)(2)
10.ALL CONDUCTORS AND RACEWAYS SHALL BE SUPPORTED ON INTERVALS AND BY METHODS REQUIRED BY THE
NEC.
11. LINE TAPS TO BE MADE WITH ILSCO KUP-L-TAP INSULATION PIERCING CONNECTOR.
12. GFI BUILT IN TO ALL INVERTERS.
SAFETY LABELS
Ai
-WARNING-
ELECTRIC SHOCK HAZARD. THE DC
CONDUCTORS OF THIS PHOTOVOLTAIC
SYSTEM ARE UNGROUNDED AND
MAY BE ENERGIZED
AUTHORIZED PERSONNEL ONLY
LOCATION: DISCONNECTS, INVERTERS,
JUNCTION BOXES, OTHER ENCLOSES
HOLDING DC CONDUCTORS
EMERGENCY RESPONDER:
THIS SOLAR PV SYSTEM IS
EQUIPPED WITH RAPID SHUTDOWN
TURN RAPID
SHUTDOWN SWITCH TO
w PR�Ii]S C
THE "OFF' POSITION
TO SHUT DOWN
LAJ_
ENTIRE PV SYSTEM
V
V)
z o
O M
H
O Q
ono
Q_
ZWo�
H 00
LIJ
H Lo U
V{ N Z N
z ro
w V�
w Z
7-) o
O' 0-
z
N W
U Z N
0
C)i,.i Lo
¢ �
V) z
r- w w N
w
W of 0
U D_ ¢ Z
W. NO.
S-4
c11 A...
Electrical Characteristics
385
390
395 400
405
410
.....
44,5
44 8
.......
45 0 45 3
45.6
__. -
45 9
®
.........
11,04
11.11
........_ .......
11.18 11.25
11,33
11.40
�
37,1
37.3
37.5 37.7
37,9
381
............
.. ..............................................
70.40
........... ...... .__-.. ..................................
10.54 10.61
..-.........
.. ..... .....
Yfl.76
.._.....
.............................10.47
19.3
.............................
19,5
............................ .........................................................10.69
19,8 20.0
............................
20.3
......__....
20.5
...
Mono crystaIluta 9busbar
'--'--.. __...
_
1,500
— ... .._.
0.347
- --
ii
...
... ..
-D.266
.. ...
... ....
...
......
_ __..__... ... - ...
+0.032
........... ....
*Al data at STC IMeaslramerr tole does PmpP t"s%; Ise We data trey W changed without prior notice
399 404 410 415 425 431
......... ......... ......... ...................... .................. ......... ... ............... ...........................
437 443 449 454 466 472
y/ .....................
475.........................._.........482.................._..................488.....................................494......................................506................._....................513 ...................
Mechanical Characteristics installation Safety Guide
• Only qualified personnel should install or
r 1,038mm(W)x1,924mm(L)x35mill perform maintenance.
.............................................................................._..__................ APProx.21.1 kg Be aware of dangerous high DC ve tage.
• Do no damage or scratch the rear surface
132 half curt bifacial cells (2 parallel x 66 half cells in series) of the module.
..................... -..... ............... _......._................................ ._............................................................... ..................... _......... -.......... Do not handle or install modules when they
L t Cable: 1,200mm/4mm2 are w 1.
Connector: MC4 genuine connector .. .....' ..........
.... Nominal Operating 45.5'G±2
IP68, weatherproof, IEC certified (UL listed) Cei.. Temperature
... ......-...... .._.... .........._-.................................................................__....................._................. Operating Temperature -401 -+85'C
3 bypass diodes to prevent power decrease by partial shade Maximum
......... .................. System Voltage DC 1,100V
Front: 3.2mm, High Transmissiorl CoateclTempered Glass Maximum ................... ...,,,,,,.. ...........
Eacapsulant EVA I Back Sheet: Black Meshed Transparent Backsheot Reverse Current 20A
... .. ........... ....... ... ....... ............ ............ ...
Anodized aluminum alloy type 6063 Maximum Front54C Pa I3c ,f;
Test Load...........................................__Rea r 4,000 Pa B 4 p.')........_......
Module Diagram (unit:m ., i-V Curves
Front Side View Rear Side View Current [Al
tz
Oil I e 14i i IIII
I I I' I tc
-1il III IIII i
'
I I I I �
. NiflIVIIIIII10111111 11 It 11 M 11111,111111JI:
I1 II �iI t l i
8
I
I 8 t}} 1
II IIII It 1i Irradian 1000W/m'
-ocearecallr P s°c
1 ,111111111 It -:0ce n 90,uT n zs•c
8 _ ._.. Opzratlng Cell Temp=85°d { t
d
jll Ifll 11�711111 111111
C - ° o to 20 30 40 so
1111111 m lllllll �RI lllllll V°¢agely]
Illllu lllllll III 11.1111 IIIIJu Il1Rl. I
UI l 11
I i Current [A]
i12
1 ,0.a to 'mad bred t 000w/
038-i. __35t03
20 5, 0.5 6 � Wid Mad 680WW
12—O�StOTT,m, r'1 d TL
_,. Nei I.lrtad—VMIW ' itGi
T
mue Iliad = zoow/m=
a to zo 3o w w
nETAIL A DETAIL B SECTION C-C' 8 D-D' VoltegelVl
:c0afrtandNWPki` %'AHYUNDAI
ENERGY SOLD IONS
IQ8 and IQ8+ Microinverters
Module compatibility
MPpTvoltagerange
Operating range
Min/max start voltage
Max input DC voltage
Max DC rltrrent',jmodule Is
Overvoltage class DC port
DC port ha0kfead current
PV array configuration
Ambient temperature is
Relative humidity range
DC Conmctortype
Dimensions (HxWxD)
Weight
Cooing
Approved for wet Iocatl
Acoustic noise at 1 in
Pgllutiondegree,
Enclosure
(1) No enforced DC/AC ratio. See the compatibility calculator at https://Iink.enphase.com/
module -compatibility (2) Maximum continuous input DC current is 101(3) Nominal voltage
range can be extended beyond nominal If required by the utility. (4) Limits may vary. Refer to
local requirements to define the number of microinverters per branch in your area. IQ8SP-DS-0002-01-EN-US-2021-10-19
c0
0 �
I
Z cV
00
m o
z¢ LitLjj
z
Q Q N �p
To
Z o
r7
o ¢
cD
Lo J
t —
Z W d�
H CI
00
W O - Lip
t1J U = d
HLnU.�
Vt N Z CV
M Of LC")
W N"
ILL)z
o
d
H
Z
D
No W
O z
III-
j 3 t-
U z to
S
z
w Q0 O
o ¢
to z U
tit ITU (n _
U
U a ¢ to
DWG. NO.
S-5
.
IF
Enphase Q Cable Accessories
O AGGREGATOR SPECIFICATIONS
Q Commercial Aggregator Q-BA-3-3P-35 (three-phase).. Combines up to three, single-phase micro nverier branches into a three
phase home run, Protect with maximum nil A, 3-pole QCPD.
€ 0nfi ,?�' 3.d`n (Q tYtihr { 17 %rs i1�U) x iisi (i'�) ,,2':in f Nll ',fir, ��y� / .rya r_ .' i:�„ „H>,> ., �,.. , .,_ ._ .:,.a ... if
Homerun conductor size range #12to #4 AWG
Temperature range -40` C to +55` C (-40' F to+122' F)
monde tiasserttbtckodir�aL67tt b ltchead canilac�s', \
' .........,. ., ,,,.,,/�� ....... ems/, . - . ;.. ,.�.. ,... . , , ,..�., ••
CONDUCTOR SPECIFICATIONS
C� t trort> 'c y; r i 1 �� 4 E r L g Icitts'fa"asserrrE)lltrs DC, caEale � , . "'
Flame test rating FT4
5r pt(ataca LX
!wv"r u; �t E t# es€sta t# cornbac ad tt�for thetJnited.'tates
WAN_ ... ...
Conductor type THHN/THWN-2 dry/wet
DiaoaY a t \ toar,s y t ulfi'd cc€otgrshave beenewatuaietl and approred layt tritse asthe load break
�/1' Eref% No '69t �`
Q CABLE TYPES !ORDERING OPTIONS
Model Number Max Nominal Voltage Connector Spacing PV Module Orientation Connector Count per Box
Pfi
Q-12-17-240 277 %'AC 2.0 m (6.5 ft) Landscape (60-cetl) 240
1-'1-Lq 263 o y /,, / , 2771iRQ / 75 ft % l tldsca °ie 72 oa[1- flU
>F... - '• „ Kam...,. \\�\.';,, . ,: /r, ., ,,,./, >„ „r „ �, ,'! ;
ENPHASE O GABLE ACCESSORIES
Name Model Number Description
It <, , 2� rs cf t, G cab e i__no 00 � r
,. .li.;auW
Field-wireable connector (rtlale) Q CONN 10M Bake connections from any Q Aggregator open connector'
i .3,
5t
. ,:,, ,' > ;
G ;;I ' c rr ect4.. r , a u ei1 a_ n „ Q h� _ Y
Cable Clip Q-CLIP-100 Used to Paster, cablingto the racking or to secure looped cabling
%Olseonnedi:Cq)
I#tSC-1 Cdolft r Q Ca61e oor€nectt r bC Connectors host C modt le r 'y
:..< ,...... via.,...... , uru,..,,, � .. .......
QA93ra -a-te sealing caps (male
) Q-BA CAR-
Q Sealing cap for unused aggregator connections
Q Qa6161eang c ps (fez ai i O ��� � e e detlto sof e y h unused c r actorurn ilea abJlhq
"Terminator Q-TERM-10 Terminator cap for unused cable ends
Rapiacme3 i daptor (M� _ u �4r f�4t 1�41t 3rgE 9) i
Replacement DC Adaptor (UTX) Q-DC;C-5 DC adaptor to €Sl X (max voitagct 100 VDC,
TERMINATOR SEALING CAPS
Terminator cap for unused cable Sealing caps for unused aggregator
ends, sold in packs of ten • and cable connections
c:::] (Q-TERM-10) (Q"BA-CAP-10 and Q SEAL 1(I)
i
I
DISCONNECT TOOL CABLE CLIP
Plan t o use at least one per -,�. , e ' -. _.__ Js.dtofa fasten 1"n t racking
i
D � _, ste cabling .othe,
� ,, g
T installation, sold in packs of ten or to secure looped cabling,sold in
1 (Q.DISC-10) `! packs often (Q-CLIP-100)
To learn more about Enphase offerings, visit enphase.com
2018 -mhase Energy. a i � iyhts rase wed All trademarks or brands used are tl•e properly f Fniphae En .1f Inc. C
Enphase IQ Combiner 4,
I Combiner 4C XIQ AM1-240-4 C) IQ Combiner 4C with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering
(ANSI CI'2.20+i-t?.5 <) and consurnption monitoring includes Enphase Mobile Connect cellular modem
(CELLMgDEM-Mt-06-SP-05', a plug -and -play Industria€-grade cell modem for systems up to 60 microinverters.
(Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, wwherathere is adequate cellular service in
the installation area.) includes a Over solar shield to match the IQ Battery end IQ Systetr Controller and to deflect heat.
ACCESSORIES AND REPLACEMENT PARTS (not included, order separately)
Circuit Breakers Supports Eaton BR210, BR215, BR220, BR230, BR240, BI2250, and BR26G ci`cult breakers.
BRK10A 2-240V Circuit breaker, 2 pole, "CA, Eaton BR210
BRK-15A 2-240V Circuit breaker, 2 pole, I5A, Eaton BR215
BRK-20A-2P 240V Circuit breaker, 2 pole, 20A, Eaton BR220
BRK-15A4 '-240V-B Circuit breaker, 2 pole, 15A, Eaton: BR2156 with hold down kit support
BRK-201 P 24r .� B Circuit breaker, 2 pole, 20A, Paton BR 2013 with hold down kit support
.'. D' �` r,€�it s, j k re € 81?'T I%alYi✓�.sr \
.9 N
..... ....:>....`*...Pa:�s///i �..._..:. _ .-.->.__.�.-..�..11..,.��-,....,,.,.
11
XA-SOLARSH:ELD-ES Replacement solar shield for IQ Corbiner 4i40
XA-ENV PCBA 3 Replacement IQ Gateway pi inted circuit board (PCl3t for 'ombirer A/4C
re
G 1aoA �f! �!� , . , �i'V .. i•Foltl dt,�r's kaffot Eaten'a qt ixracatithlrurs , `"� /3`�
ELECTRICAL SPECIFICATIONS
w I
.Pfetrn-"
n t3-bu
"
System voltage
120,1240 VAC 6 Hz
c fdtot5'� Rsenos't5.tsftar cairn ' F ', ., ir'2rS A".::
..
r
Max continuous current rating
65 A
tvYax.€'bntrrr�sou WrtenirarFLlgIilAu€'hocnPflr`s%ra '` 64A�\r
Max. fu /cr titrsting(output)
90A
...� -,
,' E..r '; C1 v'urtb (ailar, artdlm'r u +ar {3'e
U ib foie€ 2 (J 31 E'E3tC?n BP: en£`a'',l1t�'Iblied iy"en2rat€�on {�,.�i;) bE67le r5J`liY ("46't liYLti35le{f a /
4
„G„!drib.,
/
Max. total branch circuit breaker rating (input)
BOA of distributed generation. i 95A with IQ Gateway breaker included
m
YodsetMY
l
1EX,
/n
4As,4:...ad. cone
'atewaY ,;
/ii,✓„' „ >. , / :a 'r
__ .w
Consun utio , nonitoring CT (CT-200-SPI..€T)
A pair of 200 A split core cunenttransfermers
MECHANICAL DATA
Dt°neeastcnS�iiab) � / /'
37�tf445x16B€fn(1A75 xd��>{6,6 ) &ler€uhics2li'6 t�35€rrs)�trttEr€rortntittgbra�ke2.�/'H%r�' �
,�4->.
WoigM
7.5 kg (16.5les)
Cooling Natural convection plush at shield
Ea:o€6sdte anv3ronrzx�n2at fatrnj z _ v - C3uftde "4RTi, cerilT(ed NEMA2 ge RR poi'yp'arUct(%�at�rui
Wire sizes 20 A to 5.0 A breaker inputs: 14 to 4 AWO copper conductors
• 60 A breaker branch input:4 to tin AWC copper conductors
• Main lug combined output: 10 to 2i0AWG copper conductors
• Neutral and ground: 14to1i0copper conductors
Always follow local code requirements for conductor sizing.
INTERNET CONNECTION OPTIONS
me f)ierJ YF j-ot "0", S5Sibtgfse .a�
r , , ��ric: r ,
Cellular- ... .. CEl LMO€JEM, PAI-06SP OS CEI. LIAO€i EM M1-06 AT 05 (4C based I rE. MI cellular moder:e). Note that all EnPh se
Mobile Correct cellular modern is ter.uiree for all Ense-nt) e installations.
fit° ` _. opto ai Bp2 at5 (rCat � T(tEfhrme € ble (oatr El 4gd) .:'.
COMPLIANCE
Comoliance, IQ Gateway
UL 6060 I-1 /CANCSA 22.2 No. 61010=1
To learn more about Enphase offerings, visit enphase.colTl To P HAS E>
202' Dn:-Ile so, .ncrce r-.hd.:-c-,_r ed.E.nnha^, t e:.rpF x o; ,<..o ':.,men .4 ,and otlhei a P.,are. trrAernaiksof
Dat2 s.:b o- to change "-2 1-2lD2:
V
V) M
Z o
O�...r M
r C i
O
V% ¢ o
ZwOoM�t
d-
H
W CD
W v = �
Z t� M
kD
V1 N Z N
Z �M
w
w z
� O
Z
p W
o CD
� z N
CD
rn
Z
w
ern CD
2
N U
U N
Li
U
w Q CL
U a < V)
DWG. W.
S-6
Assembly 0
0
Corner Out and mark array 46 4.VA I**
0 nark
on roof.
"ay
Snap chalk lines for rail
shingle
6!
location within shingle dft
, m
Course. [Refer to module Affiff—
,me
If"
manufacturer frame '0
clamping zonesj,
Mark'mounting locations
over rafters and chalk lines
within shingle course,
Refer to engineering letters
for allowable mount spacing.
O
we
tj
AW�
�Y
or oeck attachments, follow steps in 2a, but only use Splice Foot screws in the four corners of the mount.
When possible always attach mounts to the rafter and only use deck attached as a secondary option when
a 'tp rs a re n Dt wl th 1 n rno u ntl n g zo no s fo r th a a rray. Fo flow K2 an g I nee re d ca I culatio ns a no spa n cha rts fo r d e cl<
attpchments.
When deck attaching chock
for positive engagement into Plywood and avoid plywood seams.
INFO,
Pin"neven,Roo
SurfB
of an additiona,
piece
or
uq a standard crimp
'igle starter course, leval
f
surface under the
ce Foot.
a videj on mount leveling
I
so- refer to Splice Foot
V
'Z
Dilation video: https,,//
youtube.corn/c/
ystemsusNix
A z
�10
'01
X
�w I
F- M
Z N
00
Z CD
yj Z
3 H Q m
0 N O
V
�.i
M
z QD
GD
} CD
CD
O J CM
Q _
co
W O
W U =
H Lo C-D
V{ N Z N
Z M IZ
W V"
W Z
D O
d
H
Z
D
o w
O C-D
U Z N
LO
O H
< co Ln
Z
C. ID
N Q
� U
Li
U
O O U-I
J m n-
U C I (n
DK. NO.
S-8
HYUNDAI SOLAR MODULE
YH
Dual Black Max
HiS-S385YH(BK) HIS-S390YH(BK) HiS-S395YH(BK)
SERIES HiS-S400YH(BK) HiS-S405YH(BK) HiS-S410YH(BK)
Bifacial Cells More Power UL 1,500V All black Module
Generation 7EC 1.504V or Sleek Design
In Low Light Saves BOS Costs (Black Meshed
- Backsheet)
• Mounting systemsfor
solar technology
�f item
CrossRail 48-X Technical Data Sheet
Overview:
•,�
Maximized Power
". Generation
Half -Cut &
Multi -Wire Technology
9 Wires
a///���l•••���p
—L)— Anti -LID / PID
��
Increased total power output through
Improved current flow with half -cut
Both LID(Light Induced Degradation) and
capturing light from both the front and
technology and 9 thin wiring technology
PID(Potential Induced Degradation) are
back of Bifacial solar modules. Back side
allows high module efficiency of up to
significantly reduced to ensure higher
power gain up to 25% of the front output
20.5%. It also reduces power generation
actual yield during lifetime.
depending on PV system design.
loss due to micro -cracks.
i i Mechanical Strength
UL / VDE Test Labs
QQ
Hv Reliable Warranty
Tempered glass and reinforced frame
Hyundai's R&D center is an accredited test
Global brand with powerful financial
design withstand rigorous weather
laboratory of both UL and VDE,
strength provide reliable 25-year
conditions such as heavy snow(5,400Pa)
warranty.
and strong wind(4,000Pa),
Hyundai's Warranty Provisions
About Hyundai Energy Solutions
25-Year Product Warranty
vacs • Materials and w-orkmanshp
Established in 1972, Hyundai Heavy Industres. Group is one of the most trusted names in the
hearty industries sector and is a Fortune 500 company. As a global leader and innovator, Hyundai
Feaw Industries is committed tobuilding a future arowth er:g;:^.e by developing andinvesting
25 25-Year Performance Warranty
heavily n the field of renewabie energy.
reacts •Initial year: 98.i:'-/„
As a core energy business entity o* ![Hl, iIyunuai
_nergy Solutions has stror:g pride ir: providir:g
Linear warranty after second year
high -qua ay IN products to more than 3,000 customers .vorld•-wide.
with 0.54%p annual degradation.
85.0'% a yuarantel.,ci up (aa 25 years
Certification
ML US LISiEO 11.51731, cerlzl:ed by UL. Type tifor Flue C
as4 N
vw of hvundai.e--ca.kr
z�Gi�
,
ENERGY SOLUTIONS
MECHANICAL PROPERTIES
Material:
6000 Series Aluminum
Ultimate Tensile Strength:
37.7 ksi (260 MPa)
Yield Strength:
34.8 ksi (240 MPa)
Weight:
0.56 IbsAt. (0.833 kg/m)
Finish:
Mill or Dark Anodized
SECTION PROPERTIES
Sx:
0.199 in3 (3.261 cm3)
Sy:
0.153 in3 (2.507 cm3)
A (X-Section):
0.467 in2 (3.013 cm2)
General Dimensions:
IP9] [4216.40] r —1
1.54 I 166
f
`48]
1.89
t ,
l
Dimensions in [mm] Inches
Notes:
to Structural values and span charts determined in accordance with Aluminum Design Manual and ASCE 7-10
0- UL2703 Listed System for Fire and Bonding
CrossRail 48-XTechnical Data Sheet US1-0817 @
LISTED
OL ti vo
No. 8 9
r • 441 e
r : S Wa
i • Q '• ��o
A,<nl�Po�'+�
ttttlt7 77i 1!
J
0
m
Y
U
W
U
WoW �
JCN
~ M
00 Z N
nCNo
z z
3
m
a o N o
V
_.1
� M
Z rn
O CZ)
r0
O J �
Q _
Z ckf
00
W O
W c-5
H CD
Vt N Z N
Z�'�t�i
w N"
w z
o
O
F-1
Z
o w
� 3
z N
o =
Z
w
O < O
(/7 Z U
U �
Lam.
U
w C) �p W
= a- V) U
DWG. N0.
S-9